Text

, . .

L l

l l'

ILLINOIS POWER COMPANY CLINTON POWER STATION UNIT 1 REACTOR CONTAINMENT BUILDING INTEGRATED LEAKAGE RATE TEST FINAL REPORT NRC Docket No. 50-461 December 1986 l

P Boo!

I

//

i

?

-i l TABLE OF CONTENTS p .'

_(.

1  :

./SECTION I-

>; PAGE

(;b 1.0 ' INTRODUCTION 1 L,

2

[ ' 2.0 TEST SYNOPSIS

(

) 3.0 ' TEST DATA

SUMMARY

4 4.0 ' ANALYSIS AND INTERPRETATION 11

?.

5.0 REFERENCES

'13 APPENDICES, A. ILRT Computer Programs Synopsis A-1 t '

B. ILRE)StabilihationSummaryData Temperature Stabilization Summary Report B-1 Weighted Average Temperature Plot .B-2 C. ILRT Sumnary Data Summary Data Report C-1 j Instrumentation Schematic Arrangements C-2, C-3 D. 'ILRT Calcula'tions Summary Data' Report D-1 Trend Report D-2 Mass Point Analysis D-3 Total Time Analysis D-4 Simulation Studies - Summary, Trend, Mass Point, Total Time Analysis and RTD-25 Plot Volume Fractions D-5

,I Case Study 1 D-6 Case Study 2 D-12 Case Study 3 D-18 Case Study 4 D-24 IP Program Mass Point, Total Time Analysis D-30 i

5

. E. Verification Test Summary Data E-1 Trend Report E Mass Point Analysis E-3 Total Time Analysis E-4 l, IP Program Mass Point, Total Time Analysis E-5 F. Plots - Entire Test (Stabilization, ILRT, and Verification)

Air Mass F-1 Temperature F-2 Pressure F-3 i Vapor Pressure F-4 11 i

TABLE OF CONTENTS (Cont'd)

APPENDICES (Cont'd)

Plots - ILRT Air Mass- 'F-5 Mass Point Leakage Rate and UCL F-6 Total Time Leakage Rate and UCL F-7 Weighted Average Temperature F-8 Weighted Average Pressure F-9 Weighted Average Vapor Pressure , F-10 Plots - Verification Air Mass F-11 Mass Point Leakage Rate F-12 Total Time Leakage Rate F-13 Weighted Average Temperature F-14 Weighted Average Pressure F-15 Weighted Average Vapor Pressure F-16 Plots - Data Rejection ,

Report . F-17 Weighted Average Vapor Pressure F-18 Vapor Pressure Humidity Sensor 3 F-19 Plots - Individual Sensors Pressure Sensor 1 and 2 F-20 RTD 1 thru RfD 24 F-22 Humidity Sensor i thru Humidity Sensor 9 F-46 G. Instrument Selection Guide Calculations G-1 H. Drywell Bypass Leakage Rate Test H-1

I. Type B and C Leakage Rate Test Results I-1 l

l

[

l 1

i l

iii l

L_A

1.0 INTRODUCTION

Successful-preoperational Integrated Leakage Rate (ILRT) and Drywell Bypass Leakage Rate (Bypass) Tests were conducted on the Clinton Power Station Unit I reactor containment building between November 3, 1986 and November 4, 1986. These tests were performed to demonstrate that the containment leakage and drywell bypass leakage rates do not exceed the allowable values specified in the Clinton Power Station Unit 1 FSAR (Reference 1) and Clinton Power Station Technical Specification (Reference 2).

The ILRT and Bypass tests were conducted in accordance with the requirements of the ILRT procedure (Reference 3), Appendix J to 10CFR50 (Reference 4), ANSI'56.8 (Reference 5), BN-TOP-1 (Reference 6), and ANSI 45.4 (Reference 7) . Test pressure for the ILRT and Bypass tests were 9 psig and 3 psig respectively. Test results, which satisfied all acceptance criteria, are summarized below.

Test Results Allowable ILRT Mass Point Leakage Rate

  • 0.260 %/ day 0.4875 %/ day ILRT Mass Point UCL* 0.266 %/ day 0.4875 %/ day ILRT Total Time Leakage Rate
  • 0.262 %/ day 0.4875 %/ day ILRT Total Time UCL* ~ 0.293 %/ day 0.4875 %/ day

. Verification Mass Point Rate 0.845 %/ day 0.740 to 1.066 %/ day Verification Total Time Rate 0.854 %/ day 0.742 to 1.067 %/ day Drywell Bypass Leakage Rate 20.77 scfm 4312 scfm Note: UCL is 95% Upper Confidence Limit

  • Includes penalties for nonstandard system alignment and water level changes (see section 4.0).

A summary of the test events and test chronology are presented in Section 2.0, Test Synopsis. Plant information, technical data, test results, and measurement system information are presented in Section 3.0, Test Data Summary. Test results are compared to the acceptance criteria in Seccion 4.0, Analysis and Interpretation. Referenced documents are listed in

Section 5.0, References.

l 1

2.0 TEST SYNOPSIS Prior to performing the leakage rate tests, all pressure, temperature humidity, and flow sensors were calibrated and the temperature and humidity sensors installed in the drywell and containment at the locations tabulated in Table 1. An in-situ check was performed on all sensors per the requirements of ANSI /ANS 56.8 - 1981. Per the requirements of the 10CFR50 Appendix J, the containment was isolated by aligning systems in specified post-accident mode, with the exceptions listed in Section 3.C.12. On October 23, 24, 1986 a pre-ILRT Containment and Drywell structural inspection was conducted resulting in discovery of nine temporary attachments requiring removal prior to commencing the test. All attachments were removed by November 1, 1986. No other discrepancies that would impact the test were noted.

Pressurization for the Containment ILRT began at 0957 on November 3, 1986. ILRT test pressure of 9 psig was reached at 1430 on November 3, 1986. Temperature stabilization commenced at 1430 November 3, 1986 and was completed 4.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br /> later. The BN-TOP-1 stabilization criteria of less than l'F/hr over the last 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> was met in 2) hours. The ANSI 56.8 stabilization criteria that the last hour weighted average does not deviate by more than 0.5'F from the weighted average rate of change over the last 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> was met in 4.25 hours2.893519e-4 days <br />0.00694 hours <br />4.133598e-5 weeks <br />9.5125e-6 months <br />. Temperature stabilization data is presented in Appendix B. Subsequent to the temperature stabilization period, a 9.00 hour0 days <br />0 hours <br />0 weeks <br />0 months <br /> ILRT was conducted from 1900 on November 3, 1986 to 0400 on November 4, 1986. The mass point calculated leakage rate was 0.260 %/ day with an upper confidence limit of 0.266 %/ day. The total time calculated leakage rate was 0.262 %/ day with an upper confidence limit of 0.293 %/ day. Both upper confidence limits were less than the allowable leakage rate of 0.4875 %/ day (75% of La). The total time calculations satisfied all short duration test requirements of BN-TOP-1 and the mass point calculations satisfied all short duration test requirements of ANSI /ANS 56.8-1981.

The verification test was initiated at 0515 on November 4 by continuously venting 13.04 scfm (100% of La) of air from the containment through a flowmeter and allowing test conditions to stabilize for one hour. A 41-hour verification test was conducted from 0515 to 0945 on November 4. The mass point calculated and total time calculated verification leakage rates of 0.845

%/ day and 0.854 %/ day, respectively, were within the required ranges of 0.740 to 1.066 and 0.742 to 1.067 %/ day respectively to verify the performance of '

, the ILRT instrumentation.

Following the verification test the drywell was depressurized to 3 psig l and the containment to 0 psig. The Drywell Bypass Leakage Rate Test was l performed between 1931 on November 3 and 2341 on November 3 at a test t pressure of 3 psig. A drywell bypass leakage rate of 20.77 scfm was l calculated as the leakage rate obtained during the pressure decay test.

The calculated leakage satisfied the acceptance criteria of being less than 4,312 scfm. The data and pressure decay leakage rate calculations are presented in Appendix I. Following the leakage rate test, the drywell was depressurized.

l I

l

Prior _to'the atart of pressurization it was elected to use the more.

conservative 5% data rejection criteria per ANSI 56.8. During the ILRT on November 4, at 03,15 humidity sensor No. 3 exhibited an excursion to 75.53% RH and the data set'was rejected, as it met both 1% and 5% criteria. The sensor was continuously monitored and by 0320 it read 81.8% RH, the 0300 reading being 81.63% RH and the 0330 reading being 81.81% RH. This event repeated at the 0630 and 0815 scans during the verification test, in both instances the sensor returned to normal readings within two minutes. The sensor was allowed to stabilize and the data was corrected manually in both computer pregrams.

This sensor was monitored closely for the remair.dcr of the tes.t but never exhibited any erratic behavior. other than the times noted. Subsequent to depressurization cable continuity and resistance checks were immediately conducted on the suspect cables and_ connectors. Results compared favorably to those performed prior to the test. The sensor was also examined and resistance substitution checks performed all with favorable results. The sensor electronics and DAS internal wiring will be checked thoroughly during the post test calibrations with results appropriately annotated in the Procedure Log.

During the test the RCIC exhaust steam check valve on penetration MC-41 developed a bonnett leak. The leakage rate was quantified even though it was being accounted for in the calculated containment leakage rate. This ,

penetration was not aligned in POST LOCA configuration and a _ full discussion appears in Section 3.0 and 4.0.

Subsequent to the ILRT the NRC raised the question that the main steam tunnel sub volume may not be adequately modeled by its assigned temperature sensors.

The area cooling units, in this sub volume, were in operation prior to the temperature survey thus reducing the temperature of the surrounding concrete to approximately 66*F,.even with both access doors remaining open. The adjacent areas remained at 71.9'F. This volume is a relatively small volume resembling the RWCU heat exchanger rooms. The steam tunnel and heat exchanger rooms both allow air to stagnate, hence the only effective means to add heat to the surrounding concrete and entrapped air is by conduction. For purposes of asertaining the effect, it was decided to simulate the steam tunnel volume fraction utilizing the Bechtel ILRT computer program. The Steam tunnel represents a volume fraction of 0.012 in the overall 0.165 for subvolume D so the volume fractions assigned to RTD 13, 14, 15 were reduced to 0.038 and RTD l 16 was reduced to 0.039 still totaling 0.165. Simulated sensor RTD 25 was L assigned to the steam tunnel. Since the RWCU hent Exchanger Room was being used as a conservative model the following data was compiled:

Actual Test Data Location Temp Time Date Instrument - Rate Change

  • F *F/Hr *F STM TUNNEL 0* AZ, EL. 766' 66.6 0200 11/01/86 Port. RTD --

STM TUNNEL 355* AZ, EL. 760' 66.7 0155 11/01/86 Port. RTD --

RWCU HT, EXCH. 6* AZ, EL. 816' 63.11 0645 11/01/86 RTD 10 --

RWCU HT. EXCH. 6* AZ, EL. 816' 65.73 1900 11/03/86 RTD 10 .055 2.62 RWCU HT. EXCH. 6* AZ, EL. 816' 66.09 0400 11/04/86 RTD 10 .04 0.36 RWCU HT. EXCH. 6* AZ, EL. 816' 66.27 1000 11/04/86 RTD 10 .03 0.18 Temperature sensor RTD 10 exhibits a temperature increase during ILRT representative of the warming of the walls due to conduction.

3

Four models were used to simulate the effect of additional temperature sensor RID-25 placed in the steam tunnel and assigned a volume fraction of 0.012.

The starting temperature was 69'F and the ending temperature was 70*F, both of which are conservative for if RTD-25 modeled RTD-10 the starting temperature would be 69.31*F (66.69 + 2.62*F) and the ending temperature would be 69.67'F (69.31 + 0.36).

Case No. 1 Assumed that RTD-25 remained at a constant 69'F.

Case No. 2 Assumed that RTD-25 exhibited a linear temperatures increase of 0.04*F/Hr from 69.31 to 69.67'F.

Case No. 3 Assumed that RTD-25 exhibited a linear increase from 69'F to 70*F.

Case No. 4 Assumed that RTD-25 exhibited a linear increase from 69'F to 70*F with 4 temperature perturbations.

For each of the above cases a summary report, trend report, total time analysis, and mass point analysis as well as a Plot of RTD 25 appears in Appendix D. The worst case results show a 0.004 %/ day increase to the total time UCL and 0.006 %/ day increase to the mass point UCL, these results are insignificant and as such are not included in the reported leak rate.

3.0 TEST DATA

SUMMARY

A. Plant Information Owner: Illinois Power Company Docket No.: 50-461 Plant: Clinton Power Station, Unit i Location: Clinton, IL Containment Type: Mark III, BWR NSSS Supplier, Type: General Electric, BWR Data Test Completed: November 4, 1986 B. Technical Data

1. Containment Free Air Volume
a. Drywell Free Air Volume 246,500 cu. ft.

(Normal weir wall water level, 731'-5")

b. Containment Less Drywell Volume 1,550,800 cu. ft.

(Suppression pool water level 731'-5")

c. Total Volume (Suppression pool water 1,797,300 cu. ft.

level 731'-5")

d. Drywell Free Air Volume 245,323 cu. ft.

(At start of test weir wall water level, 734'-0")

4

e. Total volume (At start of 1,778,612 cu. ft.

test suppression pool level, 734'-0")

2. Containment Design Pressure 15 psig Containment Design Temperature 185"F
3. Peak Accident Pressure, Pa 9 psig Peak Accident Temperature 185'F
4. Containment ILRT Average 40 - 120*F Temperature Limits C. Test Results Type A Test
1. Test Method Absolute

~

2. Data Analysis Techniques Mass Point Leakage Rate Per ANSI /ANS 56.8-1981; Total Time Leakage Rate per BN-TOP-1
3. Test Pressure 9 psig
4. Maximum Allowable Leakage Rate, L, 0.65 %/ day 5,

75% of L, 0.4875 %/ day

6. Integrated Rate Test Results Leakage Rate UCL*

(Not including corrections, see 4.0)

Mass Point Analysis 0.253 %/ day 0.259 %/ day Total Time Analysis 0.255 %/ day 0.286 %/ day

  • 95% Upper Confidence Limit
7. Imposed Verification Leakage Rate 0.65 %/ day (13.04* SCFM)
  • Pressure and temperature compensated value during verification test.
8. Verification Test Results Leakage Rate, %/ day Mass Point Analysis 0.845 Total Time Analysis 0.854
9. Verification Test Limits: Test Limits. %/ day Mass Point Analysis Upper Limit (L,+L,,+0.25L,) 1.066 5

. . .v 3 Lower Limit (Lg+L,,-0.25L,) 0.740 Total Time Analysis Upper Limit (Lj+L,,+0.25L,) 1.067

, Lower Limit (L,+L,,-0.25L,) 0.742

10. Report Printouts:-

The Report printouts and data plots for the ILRT and verification' test calculations are provided in Appendices B through F.

11. Containment Water Volume Changes During The ILRT.**-

Drywell Equipment Drain Sump +2.53 cu. ft. (+1.5")

Containment Floor Drain Sump , +2.56 cu. ft. (+2")

Containment Equipment Drain Sump +5.12 cu. ft. (+4")

RPV -1.84 'cu. ft. (-1")***

Suppression Pool -132.00 cu. ft. (-0. 25") ***

Fuel Storage Pool -16.67 ocu. ft. (-0.25")***

Fuel Canal +4.7 cu. ft. (+0.25")***

    • Change measured from 0 psig (start of pressurization) to 0 psig (and of depressurization).
      • Level change which is inherently included in the ILRT calculations due to pressure decrease. Suppression pool and fuel pool level changes of 0.25" is within the accuracy of the measurement device.
12. Penetrations not in Post-LOCA Alignment during ILRT
a. The following penetrations were utilized during the ILRT Penetration System Leakage Rate IMC-67 Containment Pressurization 60.00 SCCM*

IMC-152(1) ILRT Instrumentation 36.80 SCCM IMC-152(2) ILRT Instrumentation 30.20 SCCM IMC-152(3) ILRT Instrumentation 62.20 SCCM

  • Leakage Rate as a result of post ILRT Local Leak Rate Test
b. The following penetrations were in an operational line-up Penetration System Leakage Rate IMC-9 Feedwater "A" 70 SCCM IMC-10 Feedwater "B" 80 SCCM IMC-17 RHR C LPCI "C" Injection 40 SCCM IMC-35 HPCS Injection 40 SCCM '

1MC-36 LPCS Injection 70.2 SCCM IMC-63 CRD 760 SCCM IMC-21 PASS (Reactor Sample) 2.54 SCCM

c. The following penetrations were not in a post LOCA alignment and leaked during the ILRT. They have been repaired and Local Leak Rate Tested 6

l

Penetration System Leakage Rate IMC-41 RCIC Exhaust Steam Check Valve 0.10 gpm**

    • Penetration MC-41 is designed to be sealed with Suppression Pool water for a minimum of 30 days Post LOCA, hence it is tested with water and not additive to the Containment Integrated Leakage Rate.

During the ILRT, Valve IE51-F041 (the outboard check valve) leaked at a rate of 700 ML/ MIN. @P since this resulted in a respective small level decrease in Suppression Pool level and a corresponding decrease in containment pressure the leakage was included in the Containment Leak Rate. This is conservative as water leakage is not required to be added to the Integrated Leak Rate.

700 ML/ MIN = 0.185 gpm = 1.483 CFH which resulted in a 40.04 cu. ft.

volume reduction in Suppression Pool level during the 27 hour3.125e-4 days <br />0.0075 hours <br />4.464286e-5 weeks <br />1.02735e-5 months <br /> test evolution.

The approximate leakage rate attributable to this valve bonnett is:

(1.483 x 9.0) (2400) = 0.002 %/ day 1,778,612 (9.0) ,

D. Test Results - Drywell Bypass Leakage Rate Test '

1. Test Method Absolute
2. Data Analysis Technique Pressure Decay per Procedure CPS 9861.01D005, Rev. 20
3. Test Pressure Drywell 3.0 psig Containment 0.0 psig
4. Maximum Allowable Bypass Leakage Rate 4,312 scfm
5. Calculated Bypass Leakage Rate 20.77 scfm
6. Report Printouts The report printouts for the Drywell Bypass Leakage Rate Test are provided in Appendix H.

E. Test Results - Type B and C A summary of local leakage rate test results is provided in Appendix I.

7

F. Integrated Leakage Rate Measurement System Instrument (No. of Sensors) Description Date g

1. Absolute Mensor Quartz Range: 0-30 psia

. Pressure Manometer Accuracy: 0.0036 psia (2) Model No. 10100 Sensitivity: 0.0003 psia i

Repeatability: 0.0003 psia Calibration Date: 9/12/86

2. Drybulb Volumetric 100 ohm Range: 60-100*F Temperature Platinum RTD Accuracy:* 0.20*F (24) Type A Model 385 Sensitivity: 0.01*F Repeatability: 0.01*F Calibration Date: 10/9/86
3. Relative Phys. Chem. Research Range: 10-100% R.H.

Humidity Accuracy: 2*F dew point (9) Sensitivity: 0.5"F dew point Repeatability: 0.1*F dew point Calibration Date: 9/3/86

4. Flow Meter Brooks Range: 0-17 scfm (2) Rotameter Accuracy: 1% F.S.

Model No. 316 Sensitivity: 1% F.S.

Repeatability: 1% F.S.

Calibration Date: 9/16/86

  • Accuracy is for the measurement system including the Fluke 2280B Data Logger used in the 3 wire accurate mode, providing that the data logger is calibrated within 90 days, the 2280B calibration date: was 10/9/86.

Drybulb and dewpoint temperature sensor locations and volume fractions are provided in Table 1.

The calculated ISG for the test is 0.0301 %/ day, as shown in Appendix G.

i l

l i

8

TABLE 1 Drybulb and Relative Humidity Sensor Location and Volume Fractions ,

DRYBULB TEMPERATURE

-RTD Elevation Azimuth Distance From Volume Sensor Feet

  • Degree
  • Center, Feet
  • Fraction 1 900 0 25 0.070 2 900 180 25 0.070 3 872 90 30 0.070 4 872 270 30 0.070 5 854 0 30 0.046 6 854 180 30 0.046 7 845 0 0 0.046 8 837 90
  • 40 0.046 9 837 290 40 0.046 10 816 6 45 0.010 11 816 310 45 0.046 12 816 120 45 0.046 13 791 60 50 0.041

. 14 791 225 50 0.041 15 767 135 50 0.041

, 16 767 315 50 0.042 17 743 45 50 0.042 18 757 225 50 0.042 19 787 0 25 0.033 20 769 123 25 0.033 21 751 180 25 0.033 22 732 270 25 0.033 23 729 0 4 0.004 24 818 0 9 0.003 RELATIVE' HUMIDITY **

Humidity Assigned Elevation Azimuth Distance From Volume Sensor RTD*** Feet

  • Degree
  • Center, Feet
  • Fraction I 1,2,3,4 895 3 25 0.140 2 1,2,3,4 867 95 31 0.140 3 5,6,7,8,9 852 180 31 0.116 l 4 5,6,7,8,9 838 290 44 0.116 r

5 11,12 814 91 45 0.094 6 13,14,15,16 789 225 55 0.128 7 17,18 740 50 54 0.128 8 19,20,21,22 785 0 26 0.069 9 19,20,21,22 749 185 23 0.069

  • Elevations and distances to nearest foot; azimuths to nearest degree. Sensor
location tolerances radius and elevation 13'-0", Azimuth iS*, except radius l and elevation are 15'0" in the dome.

l

    • Vapor Pressure = (%R.H.) (Saturation pressure at drybulb temperature)

T1= RTD Temperature

      • Drybulb Temperature =EaggT / Ia g G

g = RTD Volume Fraction 9

F. Information Retained at Plant The following information'is available for review at'the facility:

1. -Access control procedures that were established to limit ingress to containment during testing.
2. . A listing of all containment penetrations, including penetration ,

size and function.

3. A listing of normal operating instrumentation used during the leakage rate test.
4. A system lineup (at time of test), showing required valve positions and status of piping systems.

1 j 5. A continuous, sequential log.of events from initial survey of 2 containment to restoration of all tested systems.

6. Documentation of instrumentation calibration and standards.
7. The working copies of test procedures that include signature
sign-off of procedural steps.

1

8. The procedure and all data that will verify completion of local leakage testing (type B&C tests).

) 9. Computer printouts of Integrated Leakage Rate Test Data.

I

10. The Quality Assurance audit plan or checklist that was used to monitor ILRT with proper sign-offs.
11. A listing of all test exceptions.

4 1

12. Description of sensor malfunctions.

1

13. Description of method of leak rate verification of instrument j measuring system (superimposed leakage), with calibration information on flowmeters.

I I

4 14. The P& ids of pertinent systems penetrating the containment or affected by ILRT.

~

]- 15. Drawings showing location of all temperature and humidity sensors.

I t

1 1

J J

J i 10 l

4.0 ANALYSIS AND INTERPRETATION 4.1 ILRT Test During the ILRT, the following penetrations were not in post-LOCA alignment. The penetrations together with their Type C leakage rates are given below:

Penetration System Leakage Rate 1MC-9 Feedwater "A" 70.00 SCCM IMC-10 Feedwater "B" 80.00 SCCM IMC-17 RHR C LPCI "C" Injection 40.00 SCCM IMC-35 HPCS Injection 40.00 SCCM IMC-36 LPCS Injection 70.20 SCCM IMC-63 CRD 760.00 SCCM IMC-67 Containment Pressurization 60.00 SCCM IMC-152(1) ILRT Instrumentation 36.80 SCCM IMC-152(2) ILRT Instrumentation 30.20 SCCM IMC-152(3) ILRT Instrumentation 62.00 SCCM IMC-210(3) Post Accident Sample (RPV) 2.54 SCCM IMC-41 RCIC Exhaust Steam N/A

  • TOTAL 1251.74 SCCM (0.0442 SCFM)
  • Penetration MC-41 is tested with water as it is designed to be sealed with suppression pool water post LOCA hence the leakage experienced during ILRT, is included within the containment leak rate, which is conservative.

ILRT Addition =

%/ day (1,778,612)(14.7)

= 0.0058 %/ day The following containment water volume increases were measured during the ILRT.

Drywell Equipment Drain Sump 2.53 cu. ft.

Containment Floor Drain Sump 2.56 cu. ft.

Containment Equipment Drain Sump 5.12 cu. ft.

TOTAL 10.21 cu. ft.

/ day

ILRT Addition = 0 , 612 0

= 0.0015 %/ day *

  • Based on conservative assumption that entire water volume change occurred during the 9.00 hour0 days <br />0 hours <br />0 weeks <br />0 months <br /> ILRT period.

11

J i

4.2 The total leakage rate correction for penetrations not in post-LOCA alignment and water volume changes is 0.007 %/ day.

I The calculated leakage rates during the ILRT were 0.253 %/ day (mass point) and 0.255 %/ day (total time). The calculated 95% upper confidence limits were 0.259 %/ day (mass point) and 0.286 %/ day (total time).

, Adding the total leakage rate correction for penetrations not in post-LOCA alignment and containment water volume changes yields the corrected leakage rates as follows:

Leakage Rates, %/ day Mass Point Total Time

, Leakage Rate UCL Leakage Rate UCL Calculated 0.253 0.259 0.255 0.286 Corrections 0.007 0.007 0.007 0.007 Corrected 0.260 0.266 0.262 0.293 Since the corrected 95% upper confidence limits for both mass point and total time are less than 0.75 La (0.4875 %/ day), the test results demonstrate that

. the leakage through the primary containment and systems and components penetrating primary containment does not exceed the allowable leakage rated specified in the Clinton Power Station, Unit 1 FSAR and Technical Specifications.

I

?

h l

1 r

/  ;

i i

12 i

-. - , . - - _ _ . _ .__ _ _ _ _ _ _ . - _ - _ ,- ._ _~ . . , . . , _ _ _ _ - , , _ - _ - _ -

5.0 REFERENCES

1. Clinton Power Station, FSAR.
2. Clinton Power Station, Technical Specification.
3. Clinton Power Station, Surveillance Test Procedure CPS-9861.01, Revision 20, Integrated Leak Rate Test.
4. Code of Federal Regulations Title 10, Part 50, Appendix J. Primary Reactor Containment Leakage Testing For Water Cooled Power Reactors.
5. ANSI /ANS 56.8-1981, Containment System Leakage Testing Requirements.
6. Bechtel Topical Report BN-TOP-1, Testing Criteria for Integrated Leakage Rate Testing of Primary Containment Structures for Nuclear Power Plants, Revision 1, 1972.
7. ANS-7.60/N45.4-1972 Leakage - Rate Testing of Containment Structures for Nuclear Reactors.

13

APPENDIX A ILRT Computer Program Summary l

[

APPENDIX A ILRT Computer Programs Two computer programs were available during the test the Bechtel ILRT computer program and the Illinois Power Corp ILRT computer program. The Bechtel program is the official program of record, the Illinois Power Corp. program was utilized to collect data and to provide a baseline against the Bechtel program for its future use. Leak Rate Summary Data for the Illinois Power Corp. program is presented in Appendix D and E for direct comparison against the Bechtel test results.

A

1.0 DESCRIPTION

OF BECHTEL ILRT COMPUTER PROGRAM A. Program and Report Description

1. The Bechtel ILRT computer program is used to determine the integrated leakage rate of a nuclear primary containment structure.

The program is used to compute leakage rate based on input values of time, free air volume, containment atmosphere total pressure, drybulb temperature, and dowpoint temperatureg (water vapor pressure). Leakage rate is computed using the Absolute Method as defined in ANSI /ANS 56.8-1981, " Containment System Leakage Testing Requirements" and BN-TOP-1, Rev. 1, " Test.ing Criteria for. Integrated Leakage Rate Testing of Primary Containment Structures for Nuclear Power Plants". The program is designed to allow the user to evaluate containment leakage rate test results at the jobsite during containment leakage testing. Current leakage rate values may be obtained at any time during the testing period using one of two computational methods, yielding three different report printouts.

2. In the first printout, the Total Time Report, leakage rate is computed from initial values of free air volume, containment atmosphere drybulb temperature and partial pressure of dry air, the latest values of the same parameters, and elapsed time. These individually computed leakage rates are statistically averaged using linear regression by the method of least squares. The Total Time Method is the computational technique upon which the short duration test criteria of BN-TOP-1, Rev 1, " Testing Criteria for integrated Leakage Rate Testing of Primary Containment Structures for Nuclear Power Plant", is based.
3. The second printout is the Mass Point Report and is based on the Mass Point Analysis Technique described in ANSI /ANS 56.8-1981,

" Containment System Leakage Testing Requirements". The mass of dry air in the containment is computed at each data point (time) using the Equation of State, from current values of containment atmosphere drybulb temperature and partial pressure of dry air. Contained mass is " plotted" versus time and a regression line is fit to the data using the method of least squares. Leakage rate is determined from the statistically derived slope and intercept of the regression line.

4. The third printout, the Trend Report, is a summary of leakage rate values based on Total time and Mass Point computations presented as a function of number of data points and elapsed time (test duration). The Trend Report provides all leakage rate values required for comparison to the acceptance criteria of BN-TOP-1 for conduct of a short duration test.

A-1 I

Relative liumidity sensors are used at Clinton.

5. The program is written in a high level language and is designed for use on a micro-computer with direct data input from the data acquisition system. Brief descriptions of program use, formulae used for leakage rate computations, and program logic are provided in the following paragraphs.

B. Explanation of Program

1. The Bechtel ILRT computer program is written, for use by experienced ILRT personnel, to determine containment integrated leakage rates based on the Absolute Method described in ANSI /ANS 56.8-1981 and BN-TOP-1.
2. Information loaded into the program prior to or at the start of the test:
a. Number of containmeng atmosphere drybulb temperature sensors, dewpoint temperature (water vapor pressure) sensors and pressure gages to be used in leakage rate computations for the specific test
b. Volume fractions assigned to each of the above sensors

- 4' c.' Calibration data for above sensors

d. Test title
e. Test pressure
f. Maximum allowable leakage rate at test pressure
g. Containment free air volume
3. Data received from the data acquisition system during the test, and used to compute leakage rates:
a. Time and date
b. Containment atmosphere drybulb temperatures
c. Containment atmosphere pressure (s)
d. Containmenu atmosphere dewpoint temperatures
4. Af ter all data at a given time is received, a Summary of Measured Data report (refer to " Program Logic", Paragraph D " Data" option ecmmand) is printed.
5. If drybulb and dewpoint temperature sensors should fail during the test, the data from the sensor (s) are not used. The volume fractions for the remaining sensors are recomputed and reloaded into the program for use in ensuing leakage rate computations.

A-2 1

Relative !!umidity sensors are used at Clinton.

C. Leakage Rate Formula

1. Computation using the Total Time Method:
a. Measured leakage rate, from data:

PVgg= W gRT g (1)

PVgg = W RT g (2)

L1 ,2400 (W1 -W)

Atg Wg Solving for W, and W and substituting equations (1) and (2) into (3) yields:

2400 TPV Ii1 L = 1-0E i [i11) where, W,W g g

- Weight of contained mass of dry air at times tg and tg respectively, LBM.

T,T g 1

= Containment atmosphere drybulb temperature at times tg and t grespectively, *R.

P,P g g

= Partial pressure of the dry air component of the containment atmosphere at times tg and t g respectively, psia.

V,V = Containment free air volume at times t and t I A re ectively, (constant or variable during the test),

ft st th tg. tg = Time at i and i data points respectively, hours.

At = Elasped time from tg to t g, hours.

R= Specific gas constant for air = 53.35 ft.lbf/lbm. 'R.

Lg = Measured leakage rate computed during time interval t g to t g. we.%/ day.

In order to reduce truncation error, the computer program uses the following equivalent formulation:

-2400 AW 1 L = -

1 At t (Wij A-3

where, Aw w-w Wg Wg

'AP g AV g APaV AgT i i

+ + -

P g

Vg PV g1 Tg

=

AT g g,

i AP =P g -P g .

AV = -V i

A Tf = VTf-Tf

b. Calculated leakage rate frcm regression analysis,

, L=a+b At N (5)

. where:

{

L= Calculated leakage rate, wt.%/ day, as determined from the regression line.

! a= (EL 1- bEA t t) /N N( E Lt At t ) - ( EL t) @A tg )

2 N(EA t g ) - (EA t t) 2 N= Number of data points

, N E= E i=1

c. Calculated leakage rate at the 95% confidence level.

l t

L 95 = a + b AtN+8L -

where:

L = calculated leakage rate at the 95% confidence level, 95 we.%/ day, at einsped time atN*

A-4 l

i For A t 24 N

S_, =t 0 025;N-2 [(EL - a EL g -bILpt)/(N-2)]1/2 g x [1 + 1,+ (at N )!

2 (EA t g - CA t t) 2/N)]1/2 where, t0 025;N-2 = 1.95996 - 2.37226 = 2.82250 ;

N-2 (N-2) 2 For A Nt b S_ = t0 025;N-2 [( ELg 2 - a EL - b EL g Att )/(N*2)]1/2 x [1 +( At N ~ 0 ") !

N (Ea gt 2 , ( gt )2/N]1/2 ))1/2 1.6449(N-2)2 + 3.5283(N-2) + 0.85602 where. =t o.025;N-2 =

2,g ,gg L g = Calculated leakage rate computed using equation (5) at total elasped time A t,, %/ day.

IA t g at= y f 2. Computation using the Mass Point Method

a. Contained mass of dry air from data
W = 144 P gg V

! RT g 5

where:

j All symbols are as previously defined.

i

b. Calculated leakage rate from regression analysis, W = a + b At
b

! E = -2400 -

I a i

where:

1 E = Calculated leakage rate, wt.%/ day, as determined from the regression line, i

i A-5 l

1

a = ( EWg -hE Atg )/N N( EWp gt ) - GWg) Ca tg) b =

2 NCAt g ) - GA tt)2 t

Ac = Total elasped time at time of i data point, hours 1

N = Number of data points O

W g = Contained mass of dry air at i data point, Ibm, as computed from equation (10).

N I=E i=1 In order to reduce truncation error, the computer program uses the following equivalent formulation:

a=W g 1+(Ni-beat)/N g ,

1 1 AW 0 N (E iAt)- t eat g b=W "i i g

2 N(E At g ) , gg g i)2 where, is as previously defined.

I

c. Calculated leakage rate at the 95% confidence level.

-2400 E ID~8) 95 ' , b where I'95 = calculated leakage rate at the 95% confidence level, we.%/ day.

A-6

SN 1/2 Sb " *0 025;N-2 [N It g - (EA t1 )2j i/2 where, t 0 025;N-2 ,1.6449(N-2)2 + 3.5283 (N-2) + 0.85602 (N-2)2 + 1.2209 (N-2) - 1.5162 1/2 I I(W1 - (a + b A t i)]21 N-2 j

~

f 1

-W i E(A1 W 1/W )2 _ gg ( 6,ifyl ))2fy _

(N-2

[ E ( AW1/Wi ) A t 1 -E ( AW1 /W i )( EA tt )/N]

2 E( At g ) _ (76 t ) 2 /N _j A-7

D. Program Loaic

1. The Bechtel ILRT computer program logic flow is controlled by a set of user options. The user options and a brief description of their associated function are presented below.

OPTION COMMAND FUNCTION.

After starting the program execution, the user either enters the name of the file containing previously entered data or initializes a new data file.

DATA Enables user to enter raw data. When the system requests values of time, volume, temperature, pressure and vapor pressure, the user enters the appropriate data. After completing the data entry, a summary is printed out. The user then verifies that the data was entered correctly.

If errors are detected, the user will then be given the opporttaity to correct the errors. After the user verifies that the data was entered correctly, a Corrected Data Summary Report of time, data, average temperature, partial pressure of dry air, and water vapor pressure is printed.

TREND A Tren,I Report is printed.

TOTAL A Total Time Report is printed.

HASS A Mass Point Report is printed.

TERM Enables user to sign-off temporarily or permanently. All data is saved on a file for restarting.

CORR Enables user to correct previously entered data.

LIST A Summary Data Report is printed.

READ Enables the computer to receive the next set of data from the data acquisition system directly.

PLOT Enables user to plot summary data, individual sensor data or air mass versus time.

DELETE Enables user to delete data point.

INSERT Enables user to reinstate a previously deleted data point.

VOLFRA Enables user to change volume fractions, A-8

OPTION COMMAND . FUNCTION TIME Enables the user to specify the time interval for a report or plot.

VERF Enables the user to input imposed leakage rate and calculated ILRT leakage rates at start of verification test.

E. COMPUTER REPORT AND DATA PRINTOUT MASS POINT REPORT The Mass Point Report presents leakage rate data (wt %/ day) as determined by the Mass Point Method. The " Calculated Leakage Rate" is the value determined from the regression analysis. The

" Containment Air Mass" values are the masses of dry air in the containment (1ba). These air masses, determined from the Equation of State, are used in the regression analysis.

TOTAL TIME REPORT The Total Time Report presents leakage rate data (wt %/ day) as determined by the Total Time Method. The " Calculated Leakage Rate"

  • is the value determined from the regression analysis. The " Measured Leakage Rates" are the leakage rate values determined using Total Time calculations. These values of leakage rate are used in the regression analysis.

TREND REPORT The Trend Report presents leakage rates as determined by the Mass Point and Total Time methods in percent of the initial contained mass of dry air per day (wt%/ day), versus elasped time (hours) and number of data points.

SUMMARY

DATA REPORT The Summary Data report presents the actual data used to calculate leakage rates by the various methods described in the " Computer Program" section of this report. The six column headings are TIME, DATE. TEMP, PRESSURE, VPRS, and VOLUME and contain data defined as follows:

1. TIME: Time in 24-hour notations (hours and minutes)
2. DATE: Calendar date (month and day).
3. TEMP Containment weighted-average drybulb temperature in absolute units, degrees Rankine (*R).
4. PRESSURE: Partini pressure of the dry air component of the containment atmosphere in absolute units (psia).
5. VPRS: Partial pressure of water vapor of the containment atmosphere in absolute units (pala).
6. VOLUME: Containment free air volume (cu. ft.).

A-9

A2.0 Description of Illinois Power Corp. Computer Program A. Program and Report Description

1. Calculations performed by the program are handled similarly to that stated for the Bechtel Program.
2. Leak Rate Summary Report, contains for each data point elasped time, weighted average temperature, weighted average pressure, mass point leakage and UCL, total time leakage and UCL, and containment airmass.
3. Test data reports, contain for a specific data point; values of pressure, temperature, and humidity for each individual sensor,'

assigned volume fractions, change since last data point; containment airmass, weighted average temperature, weighted average pressure, masspoint/UCL, total time /UCL; for the specific data points.

4. Plots are provided of the followings airmass vs. Time, BN TOP-1 leak rate vs. time, masspoint leak rate vs. time, and
  • individual sensors vs. time.
5. The program is written in a high level language and is designed for use on a micro computer with direct data input from the data acquisition system.

9 A-10

n

~

r ,

APPENDIX B ILRT Stabilization Summary Data

\ . - Temperature Stabalization Summary Report

- Weighted Average Temperature Plot

CLINTON POWER STATION ILRT TEMPERATURE STABILIZATION FROM A STARTING TIME AND DATE OF: 1430 1103 1986 TIME TEMP ANSI BN-TOP-1 (HOURS) ( R) AVE T AVE T DIFF AVE T (4 HRS) (1HR) (2 HRS)

.00 536.77

.25 535.73

.50 535.01

.75 534.57 -

1.00 534.28 1.25 534.07 1.50 533.92 1.75 533.79 2.00 533.70 -1.537 533.59 2.25 -1.068 2.50 533.52 .748*

2.75 533.44 .563*

3.00 533.38 .452*

3.25 533.32 .378*

3.50 533.26 .330*

3.75 533.20 .296*

4.00 533.15 .906 .231 .68 .275*

4.25 533.10 .658 .218 .44* .249*

INDICATES TEMPERATURE STABILIZATION HAS BEEN SATISFIED o

4 l CLI NTON POWER ST ATION ILRT - MTERATURE STABILIZATION TEMPERATURE DEGREES F - we1cuTeo Avta^ce l

77.200' B

i 76.440 j .

l I

75.680 i  ?

i 74.920 l

i .

73.400 , , N_

. 42:0 1102l TIME HOUFS 1l:l45 1103 START TIME DATE END TIME DATE

f APPENDIX C ILRT Summary Data Summary Data Report

- Instrumentation Schematic Arrangements e

CLINTON POWER STATION ILRT

SUMMARY

DATA ALMAX = .650 VOLUME = 1778612.

VRATET = .905 VRATEM = .903 TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 1430 1103 536.772 23.9783 .3060 1778612.0 214456.3 1445 1103 535.730 23.9265 .2999 1778612.0 214409.3 1500 1103 535.014 23.9000 .2997 1778612.0 214457.7 1515 1103 534.565 23.8825 .3010 1778612.0 214481.1 1530 1103 534.281 23.8697 .3027 1778612.0 214479.8 1545 1103 534.072 23.8606 .3033 1778612.0 214481.8 1600 1103 533.915 23.8534 .3042 1778612.0 214480.3 1615 1103 533.793 23.8502 .3019 1778612.0 214500.4 1630 1103 533.698 23.8414 .3060 1778612.0 214459.8 1645 1103 533.595 23.8367 .3065 1778612.0 214458.9 1700 1103 533.518 23.8322 .3070 1778612.0 214450.0 1715 1103 533.440 23.8283 .3075 1778612.0 214445.6 1730 1103 533.378 23.8244 .3079 1778612.0 214435.2 1745 1103 533.316 23.8208 .3084 1778612.0 2144 4 8.3 1800 1103 533.256 23.8176 .3087 1778612.0 214423.2 1815 1103 533.201 23.8145 .3090 1778612.0 214417.9 1830 1103 533.147 23.8114 .3094 1778612.0 214411.2 1845 1103 533.097 23.8087 .3097 1778612.0 214406.7 i

l C-1

ILRT IllSTRUMENTATION SCIIEMATIC 4

i e

i 2

TirP*lS$  %

Ts,P . es6 83 8

. Te #* ase 7,gg

]

84eer* 878

' TEvP= IST -

i uv sse l 71 rtw,P-is..e r ..

I ecer..T. w w ,.,s3 TE WP* st.1 IIO -

  • TEVP 84.S ygg g M8 vf-I F F gg yp ,g -

ifWP*ft.E stve*ssa "1'"3 8""

i HE W -eit p Me*

  • set _7,gg Z

W pcfwEu. ~

I

!' I i

E F=

, O 2 e o N O Tf vP= Et y 4

TavP-36)

DetwPe sts 747M FUEL $LDCi .- 755

  • ca p 6

, - gal IFE" i o

+ .1 --

I 5 FE DAS O k

~

^l_ .','s*. ~2 Ti m

it ,P- 64 .

TB iP-Wh -

33 3 14 WP* Ea E -

HE WP-479 C -IIIE

  • TW W-ET -

78 wP-870 3S vt v. ass C laon T

pea vP.see .

~

TDP-871 7tvP tit Eg" TSVP 873 .

TEw P- 814 744 % - .

Matre sel -

i f

.I

IL"T INSTPETNT^. TION SCHE!!ATIC

g. ~

y C. -

S i o - .:ICMOSIS ' 3CHo796

,g icMoeos icMo83 lMD acwogg scHoei4 8% scwoeoA

[M N X X , scHolsA J55 g 357- scHoeoc,

%)

{ h. $

C' b ICH019C,

' " scMole S

$ ,k, l Y . icHeis4 p,,.h...

w E -

A .

! t> '

AA-I N

i 7

s i

. gaTA METfJt. petyrAMETEft.

No. 1 no.1 To ATHosPHeRE -- - E

[ *c'***

icH067

?

w f E 3

i i scHOSS E

i i CMOS6

'arvoet m n.-

mm68 scMoS8 5  !

)

i. }. - - = -

IcMo34 scMotS, ICMost ICH*St 2L-t 26-t AL-S l

l .

st-4 16-J I scMoS7 BCMoh

  • ecMoso i

6 l

Gunatt . quMETE HeesoH. seeseca.

6 4

. DAS i

APPENDIX D ILRT Calculations

- Summary Data Report

- Trend Report

- Mass Point Analysis

- Total Time Analysis

- Trend Report

- Simulation Studies - Summary, Trend, Mass Point, Total Time Analysis and RTD-25 Plot

- Volume Fractions - Table 1

- Case Study 1

- Case Study 2-

- Case Study 3

- Case Study 4

- IP Program Mass Point, Total Time Analysis l

1

, -- _. _ _ _ _ - - .,v.__..-- - - - - - -

y - _,.

CLINTON POWER STATION ILRT

SUMMARY

DATA ALMAX = .650 VOLUME = 1778612.

VRATET = .905 VRATEM = .903 TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 1900 1103 533.051 23.8055 .3102 1778612.0 214397.1 1915 1103 533.005 23.8028 .3106 1778612.0 214391.2 1930 1103 532.963 23.8001 .3111 1778612.0 214383.6 1945 1103 532.918 23.7974 .3115 1778612.0 214377.5 2000 1103 532.886 23.7948 .3120 1778612.0 214366.9 2015 1103 532.848 23.7922 .3125 1778612.0 214358.5 2030 1103 532.804 23.7898 .3128 1778612.0 214354.9 2045 1103 532.769 23.7877 . .3131 1778612.0 214349.7 2100 1103 532.739 23.7852 .3136 1778612.0 214339.9 2115 1103 532.710 23.7829 .3140 1778612.0 214330.1 2130 1103 532.668 23.7808 .3143 1778612.0 214328.4 2145 1103 532.636 23.7787 .3145 1778612.0 214322.4 2200 1103 532.603 23.7767 .3149 1778612.0 214317.4 2215 1103 532.577 23.7745 .3153 1778612.0 214308.4 2230 1103 532.543 23.7726 .3156 1778612.0 214304.3 2245 1103 532.515 23.7706 .3159 1778612.0 214298.0 2300 1103 532.493 23.7687 .3163 1778612.0 214289.3 2315 1103 532.465 23.7669 .3165 1778612.0 214284.8 2330 1103 532.428 23.7651 .3167 1778612.0 214283.3 2345 1103 532.410 23.7630 .3171 1778612.0 214272.1 0 1104 532.377 23.7613 .3173 1778612.0 214269.8 15 1104 532.352 23.7597 .3176 1778612.0 214265.5

30 1104 532.324 23.7581 .3179 1778612.0 214261.8 45 1104 532.300 23.7565 .3183 1778612.0 214256.8 100 1104 532.277 23.7545 .3186 1778612.0 214248.6 115 1104 532.256 23.7529 .3189 1778612.0 214242.9 130 1104 532.227 23.7515 .3192 1778612.0 214241.4 145 1104 532.203 23.7497 .3195 1778612.0 214234.8 200 1104 532.182 23.7482 .3197 1778612.0 214229.8 l

215 1104 532.163 23.7466 .3201 1778612.0 214223.4 230 1104 532.140 23.7449 .3204 1778612.0 214217.0 245 1104 532.111 23.7435 .3205 1778612.0 214216.2 300 1104 532.090 23.7420 .3208 1778612.0 214211.4 330 1104 532.045 23.7391 .3213 1778612.0 214203.3 345 1104 532.024 23.7377 .3215 1778612.0 214198.6 400 1104 532.010 23.7361 .3219 1778612.0 214190.4 l

l l

n _1

l l

CLINTON POWER STATION ILRT TREND REPORT TIME AND DATE AT START OF TEST: 1900 1103 1986 NO. END TOTAL TIME ANALYSIS MASS POINT ANALYSIS PTS TIME MEAS. CALCULATED UCL CALCULATED UCL 2 1915 .267 .267 99.000 .267 99.000 3 1930 .304 .304 99.000 .304 .487 4 1945 .294 .301 .488 .298 .328 5 2000 .339 .332 .415 .333 .381 6 2015 .346 .348 .402 .348 .383 7 2030 .315 .340 .413 .334 .362 8 2045 .303 .330 .407 .319 .346 9 2100 .320 .330 .397 .321 .340 10 2115 .334 .334 .394 .328 .345 11 2130 .308 .329 .388 .320 .336 12 2145 .304 .323 .381 .314 .329 13 2200 .298 .317 .374 .307 .' 3 2 1 14 2215 .306 .315 .369 .306 .318 15 2230 .297 .311 .363 .301 .313 16 2245 .296 .307 .357 .298 .309 17 2300 .302 .306 .354 .298 .307 18 2315 .296 .304 .349 .296 .304 19 2330 .283 .299 .344 .291 .300 20 2345 .295 .297 .341 .290 .298 21 0 .285 .294 .337 .287 .295 22 15 .281 .291 .332 .284 .292 23 30 .275 .287 .328 .280 .288 24 45 .273 .284 .324 .277 .285 100 25 .277 .282 .320 .275 .283 26 115 .276 .279 .317 .273 .281 27 130 .268 .276 .313 .270 .278 28 145 .269 .274 .310 .268 .275 29 200 .268 .272 .307 .266 .273 30 215 .268 .270 .304 .265 .271 31 230 .269 .268 .302 .263 .270 7 32 245 .261 .266 .299 .261 .268 33 300 .260 .263 .296 .259 .265 34 330 .255 .259 .291 .256 .263 35 345 .254 .257 .288 .254 .260 36 400 .257 .255 .286 .253 .259 l

l D-2

CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

MASS POINT ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE CTMT. AIR MASS LOSS AVERAGE MASS (R) (PSIA) MASS (LBM) (LBM) LOSS (LBM/HR) 1900 533.051 23.8055 214397.1 1915 533.005 23.8028 214391.2 6.0 23.8 1930 532.963 23.8001 214383.6 7.6 27.1 1945 532.918 23.7974 214377.5 6.1 26.2 2000 532.886 23.7948 214366.9 10.6 30.3 2015 532.848 23.7922 214358.5 8.3 30.9 2030 532.804 23.7898 214354.9 3.7 28.2 2045 532.769 23.7877 214349.7 5.1 27.1 2100 532.739 23.7852 214339.9 9.8 28.6 2115 532.710 23.7829 214330.1 9.8 29.8 2130 532.668 23.7808 214328.4 1.7 27.5 2145 532.636 23.7787 214322.4 6.0 27.2 2200 532.603 23.7767 214317.4 5.0 26.6 2215 532.577 23.7745 214308.4 9.0 27.3 2230 532.543 23.7726 214304.3 4.1 26.5 2245 532.515 23.7706 214298.0 6.3 26.4 2300 532.493* 23.7687 214289.3 8.7 27.0 2315 532.465 23.7669 214284.8 4.5 26.4 2330 532.428 23.7651 214283.3 1.5 25.3 2345 532.410 23.7630 214272.1 11.1 26.3 0 532.377 23.7613 214269.8 2.4 25.5 15 532.352 23.7597 214265.5 4.3 25.1 30 532.324 23.7581 214261.8 3.7 24.6 45 532.300 23.7565 214256.8 5.0 24.4 100 532.277 23.7545 214248.6 8 ,3 24.8 115 532.256 23.7529 214242.9 5.7 24.7 130 532.227 23.7515 214241.4 1.5 24.0 145 532.203 23.7497 214234.8 6.6 24.0 200 532.182 23.7482 214229.8 5.1 23.9 215 532.163 23.7466 214223.4 6.4 24.0 230 532.140 23.7449 214217.0 6.4 24.0 245 532.111 23.7435 214216.2 .8 23.3 300 532.090 23.7420 214211.4 4.8 23.2 330 532.045 23.7391 214203.3 8.1 22.8 345 532.024 23.7377 214198.6 4.7 22.7 400 532.010 23.7361 214190.4 8.2 23.0 FREE AIR VOLUME USED (CU. FT.) =1778612.0 REGRESSION LINE INTERCEPT (LBM) = 214387.0 SLOPE (LBM/HR) = -22.6 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .259 THE CALCULATED LEAKAGE RATE = .253 D-3

1 1

.1 l

CLINTON POWER STATION ILRT i LEAKAGE RATE (WEIGHT PERCENT / DAY)

TOTAL TIME ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS '

TIME TEMP PRESSURE MEASURED (R) (PSIA) LEAKAGE RATE 1900 533.051 23.8055 1915 533.005 23.8028 .267 1930 532.963 23.8001 .304 1945 532.918 23.7974 .294 2000 532.886 23.7948 .339 2015 532.848 23.7922 .346 2030 532.804 23.7898 .315 2045 532.769 23.7877 .303 2100 532.739 23.7852 .320 2115 532.710 23.7829 .334 2130 532.668 23.7808 .308 2145 532.636 23.7787 .304 2200 532.603 23.7767 .298 ,

2215 532.577 23.7745 .306 '

2230 532.543 23.7726 .297 2245 532.515 23.7706 .296 2300 532.493 23.7687 .302 2315 532.465 23.7669 .296 2330 532.428 23.7651 .283 2345 532.410 23.7630 .295 0 532.377 23.7613 .285 15 532.352 23.7597 .281 30 532.324 23.7581 .275 45 532.300 23.7565 .273 100 532.277 23.7545 .277 115 532.256 23.7529 .276 130 532.227 23.7515 .268 145 532.203 23.7497 .269 200 532.182 23.7482 .268 215 532.163 23.7466 .268 230 532.140 23.7449 .269 245 532.111 23.7435 .261 300 532.090 23.7420 .260 330 532.045 23.7391 .255 345 532.024 23.7377 .254 400 532.010 23.7361 .257 MEAN OF THE MEASURED LEAKAGE RATES = .289 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .286 THE CALCULATED LEAKAGE RATE = .255 l

D- 4

)

I Table 1 RTD VOLUME FRACTION FOR SIMULATION STUDY Sensor No. Volume Fraction Volume Fraction As Reported ILRT Case 1.2.3 &4 1 0.0700 0.0700 _

2 0.0700 ,

0.0700 3 0.0700 0.0700 4 0.0700 0.0700 5 0.0460 0.0460 6 0.0460 0.0460 7 0.0460 0.0460 8 0.0460 0.0460 9 0.0460 0.0460 10 0.0100 0.0100 11 0.0460 0.0460 12 0.0460 0.0460 13 0.0410 0.0380 14 0.0410 0.0380 15 0.0410 0.0380 16 0.0420 0.0390 17 0.0420 0.0420 18 0.0420 0.0420 19 0.0330 0.0330 20 0.0330 0.0330 21 0.0330 0.0330 22 0.0330 0.0330 23 0.0040 0.0040 24 0.0030 0.0030 25 -

0.0120 1.0000 1.0000 l D-5 i

.a e

CASE STUDY 1 _

Steam tunnel assigned a constant temperature of 69.0 deg. F for the entire test.

9 I

l l

l D-6

o .

CASE STUDY l CLINTON POWER STATION ILRT

SUMMARY

DATA E

ALMAX = .650 VOLUME = 1778612.

VRATET = .905 VRATEM = .903 l TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 1900 1103 533.013 23.8055 .3102 1778612.0 214412.6

, 1915 1103 532.967 23.8028 .3106 1778612.0 214406.5 j 1930 1103 532.925 23.8001 .3111 1778612.0 214398.8 _

1945 1103 532.881 23.7974 .3115 1778612.0 214392.6 2000 1103 532.849 23.7948 .3120 1778612.0 214381.9

2015 1103 532.811- 23.7922 .3125 1778612.0 214373.5 2030 1103 532.767 23.7898 " . 3128 1778612.0 214369.8 l 2045 1103 532.732 23.7877 .3131 1778612.0 214364.5 2100 1103 532.702 23.7852 .3136 1778612.0 214354.6 i

2115 1103 532.674 23.7829 .3140 1778612.0 214344.8 2130 1103 532.631 23.7808 .3143 1778612.0 214342.9 i 2145 1103 532.600 23.7787 .3145 1778612.0 214336.8 2200 1103 532.567 23.7767 .3149 1778612.0 214331.8 2215 1103 532.541 23.7745 .3153 1778612.0 214322.8 2230 1103 532.508 23.7726 .3156 1778612.0 214318.6 2245 1103 532.480 23.7706 .3159 1778612.0 214312.2 2300 1103 532.458 23.7687 .3163 1778612.0 214303.5 2315 1103 532.430 23.7669 .3165 1778612.0 214298.9 2330 1103 532.393 23.7651 .3167 1778612.0 214297.3 2345 1103 532.375 23.7630 .3171 1778612.0 214286.1 0 1104 532.343 23.7613 .3173 1778612.0 214283.7 15-1104 532.318 23.7597 .3176 1778612.0 214279.4 l 30'1104 532.290 23.7581 .3179 1778612.0 214275.6 45 1104 532.266 23.7565 .3183 1778612.0 214270.5 100 1104 532.243 23.7545 .3186 1778612.0 214262.2 115 1104 532.223 23.7529 .3189 1778612.0 214256.5 130 1104 532.193 23.7515 .3192 1778612.0 214255.0 F

145 1104 532.169 23.7497 .3195 1778612.0 214248.4 200 1104 532.149 23.7482 .3197 1778612.0 214243.3 215 1104 532.130 23.7466 .3201 1778612.0 214236.8 230 1104 532.106 23.7449 .3204 1778612.0 214230.4 245 1104 532.078 23.7435 .3205 1778612.0 214229.6 300 1104 532.057 23.7420 .3208- 1778612.0 214224.7 -

330 1104 532.013 23.7391 .3213 1778612.0 214216.5 345 1104 531.991 23.7377 .3215 1778612.0 214211.7 400 1104 531.978 23.7361 .3219 1778612.0 214203.4 D-7

s CASE STUDY l l

CLINTON POWER STATION ILRT TREND REPORT TIME AND DATE AT START OF TEST: 1900 1103 1986 NO. END TOTAL TIME ANALYSIS MASS POINT ANALYSIS PTS TIME MEAS. CALCULATED UCL CALCULATED UCL 2 1915 .273 .273 99.000 .273 99.000 3 1930 .311 .311 99.000 .311 .497 4 1945 .299 .307 .504 .304 .335 5 2000 .344 .337 .423 .337 .385 6 2015 .351 .353 .408 .353 .387 7 2030 .320 .345 .418 .338 .367 8 2045 .308 .334 .411 .324 .350 9 2100 .325 .333 .401 .325 .344 10 2115 .338 .338 .398 .332 .349 11 2130 .312 .332 .391 .324 .340 12 2145 .309 .327 .384 .318 .333 13 2200 .302 .321 .377 .311 .325 14 2215 .310 .318 .372 .309 .322 15 2230 .301 .314 .365 .305 .317 16 2245 .300 .311 .360 .302 .312 17 2300 .305 .309 .356 .302 .311 18 2315 .300 .307 .352 .300 .308 19 2330 .287 .302 .347 .295 .303 20 2345 .298 .301 .343 .294 .302 21 0 .289 .298 .339 .291 .299 22 15 .284 .294 .335 .287 .295 23 30 .279 .290 .330 .284 .292 24 45 .277 .287 .326 .280 .288 25 100 .281 .285 .322 .278 .286 26 115 .280 .282 .319 .277 .284 27 130 .272 .279 .315 .274 .281 28 145 .272 .277 .312 .271 .279 29 200 .271 .274 .309 .269 .276 30 215 .271 .272 .306 .268 .274 31 230 .272 .271 .304 .266 .273 32 245 .264 .268 .301 .264 .271 33 300 .263 .266 .298 .262 .268 34 330 .258 .262 .293 .259 .266 35 345 .257 .259 .290 .257 .263 36 400 .260 .258 .288 .256 .262 D-8

CASE STUDY 1 CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

MASS POINT ANALYSIS

<t TIME AND DATE'AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE CTMT. AIR MASS LOSS AVERAGE MASS (R) (PSIA) MASS (LBM) (LBM) LOSS (LBM/HR) 1900 533.013 23.8055 214412.6 1915 532.967 23.8028 214406.5 6.1 24.4 1930 532.925 23.8001 214398.8 7.8 27.8 1945 532.881 23.7974 214392.6 6.1 26.7 2000 532.849 23.7948 214381.9 10.7 30.7 2015 532.811 23.7922 214373.5 8.4 31.3 2030 532.767 23.7898 214369.8 3.7 28.6 2045 532.732 23.7877 214364.5 5.2 27.5 2100 532.702 23.7852 214354.6 9.9 29.0 2115 532.674 23.7829 214344.8 9.9 30.2 2130 532.631 23.7808 214342.9 1.8 27.9 2145 532.600 23.7787 214336.8 6.1 27.6 2200 532.567 23.7767 214331.8 5.1 27.0 2215 532.541 23.7745 214322.8 9.0 27.7 2230 532.508 23.7726 214318.6 4.1 26.9 2245 532.480 23.7706 214312.2 6.4 26.8 2300 532.458 23.7687 214303.5 8.7 27.3 2315 532.430 23.7669 214298.9 4.6 26.8 2330 532.393 23.7651 214297.3 1.6 25.6 2345 532.375 23.7630 214286.1 11.1 26.6 0 532.343 23.7613 214283.7 2.5 25.8 15 532.318 23.7597 214279.4 4.3 25.4 30 532.290 23.7581 214275.6 3.8 24.9 45 532.266 23.7565 214270.5 5.0 24.7 100 532.243 23.7545 214262.2 8.3 25.1 115 532.223 23.7529 214256.5 5.7 25.0 130 532.193 23.7515 214255.0 1.6 24.3 145 532.169 23.7497 214248.4 6.6 24.3 200 532.149 23.7482 214243.3 5.1 24.2 215 532.130 23.7466 214236.8 6.4 24.2 230 532.106 23.7449 214230.4 6.4 24.3 245 532.078 23.7435 214229.6 .9 23.6 300 532.057 23.7420 214224.7 4.9 23.5 330 532.013 23.7391 214216.5 8.2 23.1 345 531.991 23.7377 214211.7 4.8 23.0 400 531.978 23.7361 214203.4 8.3 23.2 FREE AIR VOLUME USED (CU. FT.) =1778612.0 REGRESSION LINE INTERCEPT (LBM) = 214402.3 SLOPE (LBM/HR) = -22.8 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .262 THE CALCULATED LEAKAGE RATE = .256 D-9

s CASE STUDY l CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

TOTAL TIME ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE MEASURED (R) (PSIA) LEAKAGE RATE 1900 533.013 23.8055 1915 532.967 23.8028 .273 1930 532.925 23.8001 .311 1945 532.881 23.7974 .299 2000 532.849 23.7948 .344 2015 532.811 23.7922 .351 2030 532.767 23.7898 .320 2045 532.732 23.7877 .308 2100 532.702 23.7852 .325 2115 532.674 23.7829 .338 2130 532.631 23.7808 .312 2145 532.600 23.7787 .309 2200 532.567 23.7767 .302 2215 532.541 23.7745 .310 2230 532.508 23.7726 .301 2245 532.480 23.7706 .300 2300 532.458 23.7687 .305 2315 532.430 23.7669 .300 2330 532.393 23.7651 .287 2345 532.375 23.7630 .298 0 532.343 23.7613 .289 15 532.318 23.7597 .284 30 532.290 23.7581 .279 45 532.266- 23.7565 .277 100 532.243 23.7545 .281 115 532.223 23.7529 .280 130 532.193 23.7515 .272 145 532.169 23.7497 .272 200 532.149 23.7482 .271

, 215 532.130 23.7466 .271 230 532.106 23.7449 .272 245 532.078 23.7435 .264 300 532.057 23.7420 .263 330 532.013 23.7391 .258 345 531.991 23.7377 .257 400 531.978 23.7361 .260 MEAN OF THE MEASURED LEAKAGE RATES = .293 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .288 THE CALCULATED LEAKAGE RATE = .258 D-10

I l.

CLINTON PONER STATION ILRT - casz stunv i

! TEMPERATURE SENSOR 25 DEGREES F i 69.300 i

I i

69.200 I

l l 69.100

? .

W

! 69.000"

\ .

i 1

68.900" 68.800 . . . . . . .

.900 1103 TIME HOURS 400 1104 l START TIME DATE END TIME DATE i

l ..

.i CASE STUDY 2 Steam Tunnel assigned an increasing temperature from 69.31 deg. F to 69.67 deg. F for the test duration.

D-12

. CASE STUDY 2 CLINTON POWER STATION ILRT

SUMMARY

DATA ALMAX = .650 VOLUME = 1778612.

VRATET = .905 VRATEM = .903 TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 1900 1103 533.017 23.8055 .3102 1778612.0 214411.1 1915 1103 532.971 23.8028 .3106 1778612.0 214405.0 1930 1103 532.929 23.8001 .3111 1778612.0 214397.2 1945 1103 532.885 23.7974 .3115 1778612.0 214391.0 2000 1103 532.853 23.7948 .3120 1778612.0 214380.2 2015 1103 532.815 23.7922 .3125 1778612.0 214371.8 2030 1103 532.772 23.7898 .3128 1778612.0 214368.0 2045 1103 532.737 23.7877 .3131 1778612.0 214362.7 2100 1103 532.707 23.7852 .3136 1778612.0 214352.8 2115 1103 532.679 23.7829 .3140 1778612.0 214342.8 2130 1103 532.636 23.7808 .3143 1778612.0 214341.0 2145 1103 532.605 23.7787 .3145 1778612.0 214334.8 2200 1103 532.573 23.7767 .3149 1778612.0 214329.7 2215 1103 532.546 23.7745 .3153 1778612.0 214320.6 2230 1103 532.513 23.7726 .3156 1778612.0 214316.5 2245 1103 532.485 23.7706 .3159 1778612.0 214310.0 2300 1103 532.464 23.7687 .3163 1778612.0 214301.2 2315 1103 532.436 23.7669 .3165 1778612.0 214296.6 2330 1103 532.399 23.7651 .3167 1778612.0 214294.9 2345 1103 532.381 23.7630 .3171 1778612.0 214283.7 0 1104 532.349 23.7613 .3173 1778612.0 214281.2 15 1104 532.324 23.7597 .3176 1778612.0 214276.9 30 1104 532.296 23.7581 .3179 1778612.0 214273.0 45 1104 532.273 23.7565 .3183 1778612.0 214268.0 100 1104 532.249 23.7545 .3186 1778612.0 214259.6 115 1104 532.229 23.7529 .3189 1778612.0 214253.8 130 1104 532.200 23.7515 .3192 1778612.0 214252.2

! 145 1104 532.176 23.7497 .3195 1778612.0 214245.6 l 200 1104 532.156 23.7482 .3197 1778612.0 214240.4 215 1104 532.137 23.7466 .3201 1778612.0 214234.0 r 230 1104 532.114 23.7449 .3204 1778612.0 214227.5 l 245 1104 532.086 23.7435 .3205 1778612.0 214226.6 300 1104 532.065 23.7420 .3208 1778612.0 214221.7 330 1104 532.020 23.7391 .3213 1778612.0 214213.4 345 1104 531.999 23.7377 .3215 1778612.0 214208.5 400 1104 531.986 23.7361 .3219 1778612.0 214200.2 l

l i

i I

D-13 i

CASE STUDY 2 CLINTON POWER STATION ILRT TREND REPORT TIME AND DATE AT START OF TEST: 1900 1103 1986 NO. END TOTAL TIME ANALYSIS MASS POINT ANALYSIS PTS TIME MEAS, CALCULATED UCL CALCULATED UCL 2 1915 .275 .275 99.000 .275 99.000 3 1930 .313 .313 99.000 .313 .499 4 1945 .301 .309 .506 .306 .337 5 2000 .346 .339 .425 .340 .388 6 2015 .353 .355 .410 .355 .389 7 2030 .322 .347 .420 .340 .369 8 2045 .310 .336 .413 .326 .352 9 2100 .327 .335 .403 .327 .347 10 2115 .340 .340 .400 .334 .351 11 2130 .314 .334 .393 .326 .342 12 2145 .311 .329 .386 .320 .335 13 2200 .304 .323 .379 .313 .327 14 2215 .312 .321 .374 .311 .324 15 2230 .303 .316 .368 .307 .319 16 2245 .302 .313 .362 .304 .314 17 2300 .308 .311 .358 .304 .313 18 2315 .302 .309 .354 .302 .310 19 2330 .289 .304 .349 .297 .306 20 2345 .300 .303 .345 .296 .304 21 0 .291 .300 .341 .293 .301 22 15 .286 .296 .337 .290 .297 23 30 .281 .293 .332 .286 .294 24 45 .279 .289 .328 .282 .290 25 100 .283 .287 .325 .280 .288 26 115 .282 .285 .321 .279 .286 27 130 .274 .281 .318 .276 .283 28 145 .275 .279 .314 .273 .281 29 200 .273 .277 .311 .271 .278 30 215 .274 .275 .308 .270 .276 31 230 .274 .273 .306 .269 .275 32 245 .267 .270 .303 .266 .273 33 300 .265 .268 .300 .264 .271 34 330 .260 .264 .295 .262 .268 35 345 .259 .262 .292 .259 .266 36 400 .262 .260 .290 .258 .264 D-14

. --- - ..n , , , - . - - . - - - , , . - . , , , - . - - . . . ~ - - , . - - - , . - - , - , - - - . , . , . - - --

CASE STUDY 2.

CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

MASS POINT ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME- TEMP PRESSURE CTMT. AIR MASS LOSS AVERAGE MASS (R) (PSIA) MASS (LBM) (LBM) LOSS (LBM/HR) 1900 533.017 23.8055 214411.1 1915 532.971 23.8028 214405.0 6.2 24.6 1930 532.929 23.8001 214397.2 7.8 28.0 1945 532.885 23.7974 214391.0 6.2 26.9 2000 532.853 23.7948 214380.2 10.8 30.9 2015 532.815 23.7922 214371.8 8.5 31.5 2030 532.772 23.7898 214368.0 3.8 28.8 2045 532.737 23.7877 214362.7 5.3 27.7 2100 532.707 23.7852 214352.8 9.9 29.2 2115 532.679 23.7829 214342.8 9.9 30.'4 2130 532.636 23.7808 214341.0 1.9 28.1 2145' 532.605 23.7787 214334.8 6.1 27.7 2200 532.573 23.7767 214329.7 5.1 27.1 2215 532.546 23.7745 214320.6 9.1 27.8 2230 532.513 23.7726 214316.5 4.2 27.1 2245 532.485 23.7706 214310.0 6.4 27.0 2300 532.464 23.7687 214301.2 8.8 27.5 2315 532.436 23.7669 214296.6 4.6 27.0 2330 532.399 23.7651 214294.9 1.7 25.8 2345 532.381 23.7630 214283.7 11.2 26.8 0 532.349 23.7613 214281.2 2.5 26.0 15 532.324 23.7597 214276.9 4.3 25.6 30 532.296 23.7581 214273.0 3.8 25.1 45 532.273 23.7565 214268.0 5.1 24.9 100 532.249 23.7545 214259.6 8.4 25.3 115 532.229 23.7529 214253.8 5.7 25.2 130 532.200 23.7515 214252.2 1.6 24.4 145 532.176- 23.7497 214245.6 6.7 24.5 200 532.156 23.7482 214240.4 5.1 24.4 215 532.137 23.7466 214234.0 6.5 24.4 230 532.114 23.7449 214227.5 6.5 24.5 245 532.086 23.7435 214226.6 .9 23.8 300 532.065 23.7420 214221.7 4.9 23.7 330 532.020 23.7391 214213.4 8.3 23.3 345 531.999 23.7377 214208.5 4.8 23.2 400 531.986 23.7361 214200.2 8.3 23.4 FREE AIR VOLUME USED (CU. FT.) =1778612.0 REGRESSION LINE INTERCEPT (LBM) = 214400.8 SLOPE (LBM/HR) = -23.0 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .264 THE CALCULATED LEAKAGE RATE = .258 D-15

CASE STUDY 2 CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

TOTAL TIME ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE MEASURED (R) (PSIA) LEAKAGE RATE 1900 533.017 23.8055 1915 532.971 23.8028 .275 1930 -532.929 23.8001 .313 1945 532.885 23.7974 .301 2000 532.853 23.7948 .346 2015 532.815 23.7922 .353 2030 532.772 23.7898 .322 2045 532.737 23.7877 .310 2100 532.707 23.7852 .327 2115 532.679 23.7829 .340 2130 532.636 23.7808 .314 2145 532.605 23.7787 .311 2200 532.573 23.7767 .304 2215 532.546 23.7745 .312 2230 532.513 23.7726 .303 2245 532.485 23.7706 .302 2300 532.464 23.7687 .308 2315 532.436 23.7669 .302 2330 532.399 23.7651 .289 2345 532.381 23.7630 .300 0 532.349 23.7613 .291 15 532.324 23.7597 .286 30 532.296 23.7581 .281 45 532.273 23.7565 .279 100 532.249 23.7545 .283 115 532.229 23.7529 .282 130 532.200 23.7515 .274 145 532.176 23.7497 .275 200 532.156 23.7482 .273 215 532.137 23.7466 .274 230 532.114 23.7449 .274 245 532.086 23.7435 .267 300 532.065 23.7420 .265 330 532.020 23.7391 .260 345 531.999 23.7377 .259 400 531.986 23.7361 .262 MEAN OF THE MEASURED LEAKAGE RATES = .295 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .290 THE CALCULATED LEAKAGE RATE = .260 D-16

CLINTON POWER ST ATION ILRT - cast sruny 2 TEMPERATURE SENSOR 25 DEGREES F '

69,670 B

I "

! 69.598 f

, 69.526

!?

69.454 .

69.382'

_ /

69.310 . , , , , , , ,

.900 11EG TIME HOLIFlS 400 1104

) START TIME DATE END TIME DATE

CASE STUDY 3 Steam Tunnel assigned an increasing temperature from 69.0 deg F to 70.0 deg F for the duration of the test.

O l

i f

I i-I i

D-18

. CASE STUDY 3 CLINTON POWER STATION ILRT

SUMMARY

DATA ALMAX = .650 VOLUME = 1778612.

VRATET = .905 VRATEM = .903 TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 1900 1103 533.013 23.8055 .3102 1778612.0 214412.6 1915 1103 532.971 23.8028 .3106 1778612.0 214405.1 1930 1103 532.929 23.8001 .3111 1778612.0 214397.2 1945 1103 532.885 23.7974 .3115 1778612.0 214391.0 2000 1103 532.853 23.7948 .3120 1778612.0 214380.2 2015 1103 532.815 23.7922 .3125 1778612.0 214371.8 2030 1103 532.772 23.7898 .3128 1778612.0 214368.0 2045 1103 532.737 23.7877 .3131 1778612.0 214362.7 2100 1103 532.707 23.7852 .3136 1778612.0 214352.8 2115 1103 532.679 23.7829 .3140 1778612.0 214342.8 2130 1103 532.636 23.7808 .3143 1778612.0 214341.0 2145 1103 532.605 23.7787 .3145 1778612.0 214334.8 2200 1103 532.573 23.7767 .3149 1778612.0 214329.7 2215 1103 532.546 23.7745 .3153 1778612.0 214320.6 2230 1103 532.513 23.7726 .3156 1778612.0 214316.5 2245 1103 532.485 23.7706 .3159 1778612.0 214310.0 2300 1103 532.464 23.7687 .3163 1778612.0 214301.2 2315 1103 532.436 23.7669 .3165 1778612.0 214296.6 2330 1103 532.399 23.7651 .3167 1778612.0 214294.9 2345 1103 532.381 23.7630 .3171 1778612.0 214283.7 0 1104 532.349 23.7613 .3173 1778612.0 214281.2 15 1104 532.324 23.7597 .3176 1778612.0 214276.9 30 1104 532.296 23.7581 .3179 1778612.0 214273.0 45 1104 532.273 23.7565 .3183 1778612.0 214268.0 100 1104 532.249 23.7545 .3186 1778612.0 214259.6 115 1104 532.229 23.7529 .3189 1778612.0 214253.8 130 1104 532.200 23.7515 .3192 1778612.0 214252.2 145 1104 532.176 23.7497 .3195 1778612.0 214245.6 200 1104 532.156 23.7482 .3197 1778612.0 214240.4 215 1104 532.137 23.7466 .3201 1778612.0 214234.0 230 1104 532.114 23.7449 .3204 1778612.0 214227.5

, 245 1104 532.086 23.7435 .3205 1778612.0 214226.6 300 1104 532.065 23.7420 .3208 1778612.0 214221.7 330 1104 532.022 23.7391 .3213 1778612.0 214212.8 345 1104 532.001 23.7377 .3215 1778612.0 214207.7 400 1104 531.990 23.7361 .3219 1778612.0 214198.6

)

D-19

CASE STUDY 3 CLINTON POWER STATION-ILRT TREND REPORT TIME AND DATE AT START OF TEST: 1900 1103 1986 NO. END TOTAL TIME ANALYSIS MASS POINT ANALYSIS PTS TIME MEAS. CALCULATED UCL CALCULATED UCL 2 1915 .338 .338 99.000 .338 99.000 3 1930 .345 .345 99.000 .345 .382 4 1945 .323 .328 .445 .326 .359 5 2000 .363 .350 .443 .353 .394 6 2015 .366 .362 .422 .365 .393 7 2030 .333 .350 .412 .348 .375 8 2045 .319 .337 .398 .332 .358 9 2100 .335 .335 .388 .331 .352 10 2115 .347 .339 .386 .338 .355 11 2130 .321 .332 .377 .329 .346 12 2145 .317 .326 .369 .323 .338 13 2200 .309 .320 .360 .315 .330 14 2215 .317 .317 .355 .313 .326 15 2230 .308 .313 .348 .309 .321 16 2245 .306 .309 .343 .306 .317 17 2300 .312 .307 .340 .305 .315 18 2315 .306 .305 .336 .303 .312 19 2330 .293 .300 .330 .298 .307 20 2345 .304 .298 .327 .297 .305 21 0 .294 .295 .323 .294 .302 22 15 .289 .292 .319 .290 .299 23 30 .284 .288 .314 .287 .295 24 45 .282 .284 .310 .283 .291 25 100 .286 .282 .307 .281 .289 26 115 .284 .280 .304 .279 .287 27 130 .276 .277 .301 .276 .284 28 145 .277 .274 .298 .274 .281 29 200 .275 .272 .295 .272 .279 30 215 .276 .270 .292 .270 .277 31 230 .276 .268 .290 .269 .276 32 245 .269 .266 .288 .267 .273 33 300 .267 .264 .285 .265 .271 34 330 .263 .259 .280 .262 .269 35 345 .262 .257 .278 .260 .266 36 400 .266 .255 .276 .259 .265 D-20

CASE STUDY 3 CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

MASS POINT ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE CTMT. AIR MASS LOSS AVERAGE MASS (R) (PSIA) MASS (LBM) (LBM) LOSS (LBM/HR) 1900 533.013 23.8055 214412.6 1915 532.971 23.8028 214405.1 7.5 30.2 1930 532.929 23.8001 214397.2 7.9 30.9 1945 532.885 23.7974 214391.0 6.2 28.9 2000 532.853 23.7948 214380.2 10.8 32.4 2015 532.815 23.7922 214371.8 8.5 32.7 2030 532.772 23.7898 214368.0 3.8 29.8 2045 532.737 23.7877 214362.7 5.3 28.5 2100 532.707 23.7852 214352.8 9.9 29.9 2115 532.679 23.7829 214342.8 9.9 31.0 2130 532.636 23.7808 214341.0 1.9 28.7 2145 532.605 23.7787 214334.8 6.1 28.3 2200 532.573 23.7767 214329.7 5.1 27.6 2215 532.546 23.7745 214320.6 9.1 28.3 2230 532.513 23.7726 -214316.5 4.2 27.5 2245 532.485 23.7706 214310.0 6.4 27.4 2300 532.464 23.7687 214301.2 8.8 27.9 2315 532.436 23.7669 214296.6 4.6 27.3 2330 532.399 23.7651 214294.9 1.7 26.2 2345 532.381 23.7630 214283.7 11.2 27.1 0 532.349 23.7613 214281.2 2.5 26.3 15 532.324 23.7597 214276.9 4.3 25.9 30 532.296 23.7581 214273.0 3.8 25.4 45 532.273 23.7565 214268.0 5.1 25.2 100 532.249 23.7545 214259.6 8.4 25.5 4

115 532.229 23.7529 214253.8 5.7 25.4 130 532.200 23.7515 214252.2 1.6 24.7 145 532.176 23.7497 214245.6 6.7 24.8 200 532.156 23.7482 214240.4 5.1 24.6 215 532.137 23.7466' 214234.0 6.5 24.6 230 532.114 23.7449 214227.5 6.5 24.7 245 532.086 23.7435 214226.6 .9 24.0 300 532.065 23.7420 214221.7 4.9 23.9 330 532.022 23.7391 214212.8 8.8 23.5 345 532.001 23.7377 214207.7 5.1 23.4 400 531.990 23.7361 214198.6 9.1 23.8 FREE AIR VOLUME USED (CU. FT.) =1778612.0 REGRESSION LINE INTERCEPT (LBM) = 214401.1 S LOPE (LBM/HR) = -23.1 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .265 THE CALCULATED LEAKAGE RATE = .259 D-21

CASE STUDY 3 CLINTON-POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

TOTAL TIME ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE MEASUREC (R) (PSIA) LEAKAGE RATE 1900 533.013 23.8055 1915 532.971 23.8028 .338 1930 532.929 23.8001 .345 1945 532.885 23.7974 .323 2000 532.853 23.7948 .363 2015 532.815 23.7922 .366 2030 532.772 23.7898 .333 l 2045 532.737 23.7877 .319 2100 532.707 23.7852 .335 2115 532.679 23.7829 .347 2130 532.636 23.7808 .321 2145 532.605 23.7787 .317 2200 532.573 23.7767 .309

2215 532.546 23.7745 .317 2230 532.513 23.7726 .308 2245 532.485 23.7706 .306 2300 -532.464 23.7687 .312 2315 532.436 23.7669 .306 ~

2330 532.3e9 23.7651 .293

2345 532.381 23.7630 .304 I O 532.349 23.7613 .294 l 15 532.324 '23.7597 .289

, 30 532.296 23.7581 .284 45 532.273 23.7565 .282 100 532.249 23.7545 .286 115 532.229 23.7529 .284 l 130 532.200 23.7515 .276 145 532.176 23.7497 .277 r 200 532.156 23.7482 .275 l 215 532.137 23.7466 .276 230 532.114 23.7449 .276 245 532.086 23.7435 .269

! 300 532.065 23.7420 .267 330 532.022 23.7391 .263

345 532.001 23.7377 .262 400 531.990 23.7361 .266 MEAN OF THE MEASURED LEAKAGE RATES = .303 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .276 THE CALCULATED LEAKAGE RATE = .255 I

D-22 I

CASE' STUDY 3' 3 i

s

(

~

CLINTON POWER STATION ILRT j LEAKAGE RATE (WEIGHT PERCENT '/ DAY)

TOTAL TIME ANALYSIS

' TIME AND DATE AT START OF TEST: 1900 1103 1985' TEST DURATION: 9.00 HOURS

': TIME TEMP PRESSURE MEASURED (R) (PSIA) LEAKAGE RATE I --------------------------------------

1900 533.013 23.8055 1915 532.971 23.8028 .338 1930 532.929 23.8001 .345 1945 532.885 23.7974 .323 2000 532.853 23.7948 .363 2015 532.815 23.7922 .366

., 2030 532.772 23.7898 .333 2045 532.737 23.7877 .319 2100 532.707 23.7852 .335

\ 2115 532.679 23.7829 .347 2130 532.636 23.7808 .321 2145 532.605 23.7787 .317 2200 532.573 23.7767 .309 2215 532.546 23.7745 .317 2230 532.513 23.7726 .308

, 2245 532.485 23.7706 .306 2300 532.464 23.7687 .312

'2315 532.436 23.7669 .306 2330 532.399 23.7651 .293 2345 532.381 23.7630' .304 0 532.349 23.7613 .294 15 532.324 23.>7597 .289 30 532.296 23.7581 . .284

.45 532.273 23.7565 .282 100 532.249 23.7545 .286 l

115 532.229 23.7529 .284 130 532.200 23.7515 .276 s 145 532.176 23 7437 .277 200 532.156 70.7-82 .275 215 532.137 3.7'66 .276 230 532.114 gl S49 .276 i

245 532.086 23.1435 .269 300 532.065 23.7420 .267 330 532.022 23.7391 .263 345 532.001 23.7377 .262 400 531.990 23.7361 .266 MEAN OF THE MEASURED LEAKAGE RATES = .303 MAXIMUM ALLOWABLE LEAKAGE RATE = . 650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = . 487

, THE UPPER 95% CONFIDENCE LIMIT = . 276 THE CALCULATED LEAKAGE RATE = . 255 l

l D-22 1

l

i CLINTON POWER STATION ILRT - cass sruny 3

TEMPERATURE SENSOR 25 DEGREES F 70.000 1
69.800 B

69 600 69.400" -

1 l

69.200"

\ -

l 69.000_ , , , , , , ,

1900 1103 TIME HOUFlS 400 1104 START TIME DATE END TIME DATE

..i .  :

=

a l'

3-d CASE STUDY 4 Steam tunnel assigned same temperature as Case Study 4 with four '

temperature perturbations during the test period.  ;

m I

4 4

! i a

1 l

i i

1 D-24

. ,.p_, _ . _ _ , - -.,,,_-_.-,_,_,_,,.,-__,.7..,-_,.,

, ..., , ,.,y,,_,.,y...,-m.m..w,,-.,. ,_ , , . _ _ . - - , , . _ , ,

J. CASE STUDY 4 CLINTON POWER STATION ILRT

SUMMARY

DATA ALMAX = .650 VOLUME = 1778612.

. VRATET = .905 VRATEM = .903 '

TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 1900 1103 533.013 23.8055 .3102 1778612.0 214412.6 1915 1103- 532.971 23.8028 .3106 1778612.0 214405.1 '

1930.1103 532.929 23.8001 .3111 1778612.0 214397.2 1945 1103 532.885 23.7974 .3115 1778612.0 214391.0 2000 1103 532.853 23.7948 .3120 1778612.0 214380.2 2015 1103 532.815 23.7922 .3125 1778612.0 214372.0 2030 1103 532.772 23.7898 *. 3128 1778612.0 214368.0 2045 1103 532.737 23.7877 .3131 1778612.0 214362.7 1

2100 1103 532.707 23.7852 .3136 1778612.0 214352.8 2115 1103 532.679 23.7829 .3140 1778612.0 214342.8 2130 1103 532.636 23.7808 .3143 1778612.0 214341.0 2145 1103 532.605 23.7787 .3145 1778612.0 214334.8 2200 1103 532.573 23.7767 .3149 1778612.0 214329.4 2215 1103 532.546 23.7745 .3153 1778612.0 214320.6 2230 1103 532.513 23.7726 .3156 1778612.0 214316.5 2245 1103 532.485 23.7706 .3159 1778612.0 214310.0 4: 2300 1103 532.464 23.7687 .3163 1778612.0 214301.2 2315 1103 532.436 23.7669 .3165 1778612.0 214296.6 2330 1103 532.399 23.7651 .3167 1778612.0 214294.9 2345 1103 532.381 23.7630 .3171 1778612.0 214283.7 0 1104 532.349 23.7613 .3173 1778612.0 214281.2 15 1104 532.324 23.7597 .3176 1778612.0 214276.9 30 1104 532.296 23.7581 .3179 1778612.0 214273.0

. '45 1104 532.273 23.7565 .3183 1778612.0 214268.0 100 1104 532.249 23.7545 .3186 1778612.0 214259.6 115 1104 532.229 23.7529 .3189 1778612.0 214254.0 130 1104 532.200 23.7515 .3192 1778612.0 214252.2 -

145 1104 532.176 23.7497 .3195 1778612.0 214245.6

--200 1104 532.156 23.7482 *

.3197 1778612.0- 214240.4 215 1104 532.137 23.7466 .3201 1778612.0 214234.,0 230 1104 532.114 23.7449 .3204 1778G12.0 214227.5 245 1104 532.087 23.7435 .3205 1778612.0 214226.2 300 1104 532.065 23.7420 .3208 1778612.0 214221.7 330 1104 532.022 23.7391 .3213 1778612.0 214212.8

, 345 1104 532.001 23.7377 .3215 1778612.0 214207.7 400 1104 531.990 23.7361 .3219 1778612.0 214198.6 i

4 n

D-25

a CASE STUDY 4 CLINTON POWER STATION ILRT TREND REPORT TIME AND DATE AT START OF TEST: 1900 1103 1986 NO. END TOTAL TIME ANALYSIS MASS POINT ANALYSIS PTS TIME MEAS. CALCULATED UCL CALCULATED UCL 2 1915 .338 .338 99.000 .338 99.000 3 1930 .345 .345 99.000 .345 .382 4 1945 .323 .328 .445 .326 .359 5 2000 .363 .350 .443 .353 .394 6 2015 .364 .360 .420 .363 .390 7 2030 .333 .349 .409 .347 .373 8 2045 .319 .336 .395 .331 .357 9 2100 .335 .335 .385 .331 .351 10 2115 .347 .339 .385 .338 .354 11 2130 .321 .332 .376 .329 .345 12 2145 .317 .326 .367 .323 .338 13 2200 .311 .320 .359 .316 .330 14 2215 .317 .317 .354 .314 .326 15 2230 .308 .313 .348 .309 .321 16 2245 .306 .309 .342 .306 .317 17 2300 .312 .307 .339 .305 .315 18 2315 .306 .305 .335 .303 .312 19 2330 .293 .300 .329 .298 .307 20 2345 .304 .298 .327 .297 .305 21 0 .294 .295 .323 .294 .302 22 15 .289 .292 .318 .291 .299 23 30 .284 .288 .314 .287 .295 24 45 .282 .285 .310 .283 .291 25 100 .286 .282 .307 .281 .289 26 115 .284 .280 .304 .279 .287 27 130 .276 .277 .300 .276 .284 28 145 .277 .274 .297 .274 .281 29 200 .275 .272 .294 .272 .279 30 215 .276 .270 .292 .270 .277' 31 230 .276 .268 .290 .269 .276 32 245 .269 .266 .287 .267 .273 33 300 .267 .264 .285 .265 . 17 1 34 330 .263 .259 .279 .262 .269 35 345 .262 .257 .277 .260 .266 36 400 .266 .256 .276 .259 .265 D-26

CASE STUDY 4 CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

MASS POINT ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE CTMT. AIR MASS LOSS AVERAGE MASS (R) (PSIA) MASS (LBM) (LBM) LOSS (LBM/HR) 1900- 533.013 23.8055 214412.6 1915 532.971 23.8028 214405.1 7.5 30.2 1930 532.929 23.8001 214397.2 7.9 30.9 1945 532.885 23.7974 214391.0 6.2 28.9 2000 532.853 23.7948 214380.2 10.8 32.4 2015 532.815 23.7922 214372.0 8.2 32.5 2030 532.772 23.7898 214368.0 4.1 29.8 2045 532.737 23.7877 214362.7 5.3 28.5 2100 532.707 23.7852 214352.8 9.9 29.9 2115 532.679 23.7829 214342.8 9.9 31.0 2130 532.636 23.7808 214341.0 1.9 28.7 2145 532.605 23.7787 214334.8 6.1 28.3 2200 532.573 23.7767 214329.4 5.5 27.8 2215 532.546 23.7745 214320.6 8.7 28.3 2230 532.513 23.7726 214316.5 4.2 27.5 2245 532.485 23.7706 214310.0 6.4 27.4 2300 532.464 23.7687 214301.2 8.8 27.9 2315 532.436 23.7669 214296.6 4.6 27.3

  • 2330 532.399 23.7651 214294.9 1.7 26.2 .

2345 532.381 23.7630 214283.7 11.2 27.1 0 532.349 23.7613 214281.2 2.5 26.3 1 15 532.324 23.7597 214276.9 4.3 25.9 '

30 532.296 23.7581 214273.0 3.8 25.4 45 532.273 23.7565 214268.0 5.1 . 25.2 100 532.249 23.7545 214259.6 8.4 25.5 115 532.229 23.7529 214254.0 5.5 25.4 ~

130 532.200 23.7515 214252.2 1.8 24.7 145 532.176 23.7497 214245.6 6.7 24.8 200 532.156 23.7482 214240.4 5.1 24.6 215 532.137 23.7466 214234.0 6.5 24.6 230 532.114 23.7449 214227.5 6.5 24.7 245 532.087 23.7435 214226.2 1.3 24.1 300 532.065 23.7420 214221.7 4.5 23.9 330 532.022 23.7391 214212.8 8.8 23.5 345 532.001 23.7377 214207.7 5.1 23.4 400 531.990 23.7361 214198.6 9.1 23.8 FREE AIR VOLUME USED (CU. FT.) = 1778612.0 REGRESSION LINE INTERCEPT (LBM) = 214401.1 SLOPE (LBM/HR) = -23.1 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 i THE UPPER 95% CONFIDENCE LIMIT = .265 THE CALCULATED LEAKAGE RATE = .259 D-27 y- -r --,w v , - --- ,,+my- ----+ye ,--ym,w,--m+ yW-p - yww-ew-- -g.- - - - ..m. q

  • 47 1 r---

CASE STUDY 4 CLINTON POWER STATION ILRT

  • LEAKAGE RATE (WEIGHT PERCENT / DAY)

TOTAL TIME ANALYSIS TIME AND DATE AT START OF TEST: 1900 1103 1986 TEST DURATION: 9.00 HOURS TIME TEMP PRESSURE MEASURED (R) (PSIA) LEAKAGE RATE 1900 533.013 23.8055 1915 532.971 23.8028 .338 1930 532.929 23.8001 .345 1945 532.885 23.7974 .323 2000 532.853 23.7948 .363 2015 532.815 23.7922 .364 2030 532.772 23.7898 .333 2045 532.737 23.7877 .319 2100 532.707 23.7852 .335 2115 532.679 23.7829 .347 2130 532.636 23.7808' .321 2145 532.605 23.7787 .317 2200 532.573 23.7767 .311 2215 532.546 23.7745 .317 2230 532.513 23.7726 .308 2245 532.485 23.7706 .306 2300 532.464 23.7687 .312 2315 532.436 23.7669 .306 2330 532.399 23.7651 .293 2345 532.3.81 23.7630 .304 0 532.349 23.7613 .294 15 532.324 23.7597 .289 30 532.296 23.7581 .284 45 532.273 23.7565 .282 100 532.249 23.7545 .286 115 532.229 23.7529 .284 130 532.200 23.7515 .276 145 532.176 23.7497 .277 200 532.156 23.7482 .275 215 532.137 23.7466 .276 230 532.114 23.7449 .276 245 532.087 23.7435 .269 300 532.065 23.7420 .267 330 532.022 23.7391 .263 345 532.001 23.7377 .262 400 531.990 23.7361 .266 f

MEAN OF THE MEASURED LEAKAGE RATES = .303 MAXIMUM ALLOWABLE LEAKAGE RATE = .650 75% OF MAXIMUM ALLOWABLE LEAKAGE RATE = .487 THE UPPER 95% CONFIDENCE LIMIT = .276 THE CALCULATED LEAKAGE RATE = .256 D-28

CLINTON POWER ST ATION ILRT - CASE STUDY 4

TEMPERATURE SENSOR 25 DEGREES F 70.000 i

69.800 B

! 69.600 .

i v -

O "

69.400 ,

I 69.200"

! 69.800 , , ., , , . ,

.900 1103' TIME HOURS 40011104 START TIME DATE END TIME DATE

TLLINOIS POWER CO.

CLINTON POWER STATION ILRT PROGRAM LEAK RATE

SUMMARY

Start Time:11- 3-86 19: 0 End Time:11- 4-86 4: 0 Duration: 9 000 HOURS DELETED: 8.250 MASS POINT METHOD TOTAL TIME METHOD

> ELAPSED TEMP PRESSURE LEAK 95% LEAK 95% CTMT.

TIME RATE UCL RATE UCL AIRMASS

_(HOURS) (DEG.R) (PSIA) (%/ DAY) (%/ DAY) (%/ DAY) (%/ DAY) (LBM)

.750 532.918 23.7975 .298 .326 .301 .481 214378 1.000 532.886 23.7949 .332 .381 .331 .414 214367 1.250 532.848 23-7923

. .348 .382 .348 .401 214359 1.500 532.804 23.7899 .334 . .362 .340 .411 214355 1.750 532.769 23.7878 .319 .345' .329 .405 214350 2.000 532.739 23.7853 .320 .340 .329 .396 214340 2.250 532.710 23.7830 .328 .345 .334 .393 214330 2.500 532.667 23.7809 .320 .336 .328 .387 214328 2.750 532.636 23.7788 .314 .328 .323 .380 .214322 3.000 532.603 23.7768 .307 .321 .317 .373 214317 3.250 532.577 23.7746 .305 .318 .315 .367 214309 3.500 532.543 23.7726 .301 .313 .311 .362 214304 3.750 532.515 23.7707 .298 .308 .307 .356 214298 4.000 532.493 23.7688 .298 .307 .306 .352 214289 4.250 532.465 23.7670 .296 .304 .303 .348 214285 4.500 532.428 23.7652 .291 .300 .299 .343 214283 4.750 532.410 23.7631 .290 .298 .297 .340 214272 5.000 532.377 23.7614 .287 .295 .294 .336 214270 5.250 532.352 23.7598 .284 .292 .291 '

.331- 214266 5.500- 532.324 23.7582 .280 .288 .287 .327 214262 5.750 532.300 23.7566 .277 .285 .284 .323 214257 6.000.

~

532.277 23.7546 .275. .282 .281 .319 214249 6.250 532.2'6 5 2'3.7530 .273 .280 .279 .316 214243 6.500 532.227 23.7516 .270 .278 .276 .312 214242 6.750 532.203 23.7498 .268 .275 .274 .309 214235 7.000 532.182 23.7483 .266 .273 .271 .306 214230 7.250 532.163 23.7467 .264 .271 .269 .303 214224 7.500 532.140 23.7450 .263 .270 .268 .301 214217

  • 7.750 532.111 23.7436 .261 .267 .265 .298 214216 8.000 532.090 23.7421 .259 .265 .263 .295 214212

-8.250 532.064 23.7432 .259 .265 .261 .293 214231 8,500 532.045 23.7392 .256 .263 .259 .290 214203 8.750 532.024 23.7378 .254 .260 .257 .287 214199 9.000 532.~010 23.7362 .252 .259 .255 .285 214191 D-30

ILLINOIS POWER CO.

CLINTON POWER STATION ILRT PROGRAM TEST DATA Page 37 Date 11- 4-86

  • Time 4: O Start Time =19: 0 Elapsed Time: 9.000 Hours Sample Interval:15. Minutes Start Date:11- 3-86 VOLUME CHANGE FROM

, DATA # DESCRIPTION VALUE FRACTION PREVIOUS SAMPLE 1 PRESSURE 1 24.057 PSIA .50000 .001 2 PRESSURE 2 24.059 PSIA .50000 .001 3 TEMPERATURE 1 72.700 DEGF .07000 .020 4 TEMPERATURE 2 72.640 DEGF .07000 .020 5 TEMPERATURE 3 72.550 DEGF .07000 .030 6 TEMPERATURE 4 72.660 DEGE .07000 .050 7 TEMPERATURE 5 72.770 DEGF .04600 .020 8 TEMPERATURE 6 73.020 DEGF .04600 .020 9 TEMPERATURE 7 73.100 DEGF .04600 .010 10 TEMPERATURE 8 73.060 DEGF .04600 .000 11 TEMPERATURE 9 73.060 DEGF .04600 .030 12 TEMPERATURE 10 66.090 DEGF .01000 .010 13 TEMPERATURE 11 71.940 DEGF .04600 .020 14 TEMPERATURE 12 72.370 DEGF .04600 .010 15 TEMPERATURE 13 72.350 DEGF .04100 .010 16 TEMPERATURE 14 71.820 DEGF .04100 .010 17 TEMPERATURE 15 71.420 DEGF .04100 .000 18 TEMPERATURE 16 71.250 DEGF .04200 .020 19 TEMPERATURE 17 69.990 DEGF .04200 .010 20 TEMPERATURE 18 71.210 DEGF .04200 .030 .

21 TEMPERATURE 19 73.810 DEGF .03300 .00U 22 TEMPERATURE 20 73.340 DEGF .03300 .020

. 23 TEMPERATURE 21 72.840 DEGF .03300 .0f0 24 TEMPERATURE 22 72.250 DEGF .03300 .010 25 TEMPERATURE 23 71.640 DEGF .00400 .010 26 TEMPERATURE 24 73.110 DEGF .00300 .020 27 HUMIDITY 1 83.820 %REL .14000 .100

  • 28 HUMIDITY 2 82.830 %REL .14000 .080 29 HUMIDITY 3 82.020 %REL .11600 .090 30 HUMIDITY 4 82.020 %REL .1160'O .090 31 HUMIDITY 5 84.000 %REL .09400 .060 32 HUMIDITY 6 84.790 %REL .12800 .030 33 HUMIDITY 7 89.890 %REL .12800 .010 34 HUMIDITY 8 67.040 %REL .06900 .450 35 HUMIDITY 9 68.390 %REL .06900 .420 AIRMASS: 214191. LBM TEMP:72.3400 DEGF PRESSURE =23.7362 PSIA MASSPOINT TOTAL TIME METHOD METHOD LEAK RATE .252 %/ DAY . 255 *UDAY 96% UCL 269 %/ DAY .285 %/ DAY DELETED: 8.260 D-31 ._ _

APPENDIX E Verification Test

- Summary Data

- Trend Report

- Mass Point Analysis

- Total Time Analysis

- IP Program Mass Point, Total Time Analysis 4

VERIFICATION CLINTON POWER STATION ILRT

SUMMARY

DATA

, ALMAX = .650 VOLUME = 1778612.

VRATET = .905 VRATEM = .903 TIME DATE TEMP PRESSURE VPRS VOLUME AIRMASS 515 1104 531.895 23.7209 .3229 1778612.0 214099.6 530 1104 531,874 23.7182 .3231 1778612.0 214082.9 545 1104 531.854 23.7152 .3233 1778612.0 214064.6 600 1104 531.839 23.7121 .3236 1778612.0 214042.6 615 1104 531.818 23.7092 .3238 1778612.0 214024.7 630 1104 531.800 23.7066 .3240 1778612.0 214007.9 645 1104 531.783 23.7036 . 3242 1778612.0 213988.5 700 1104 531.764 23.7006 .3244 1778612.0 213968.8 715 1104 531.751 23.6979 .3247 1778612.0 213949.6 730 1104 531.730 23.6950 .3249 1778612.0 213932.1 745 1104 531.712 23.6921 .3250 1778612.0 213913.1 800 1104 531.697 23.6891 .3253 1778612.0 213892.1 815 1104 531.681 23.6862 .3255 1778612.0 213872.2 830 1104 531.662 23.6836 .3257 1778612.0 213856.6 845 1104 531.647 23.6809 .3259 1778612.0 213837.7 900 1104 531.632 23.6782 .3262 1778612.0 213819.7 915 1104 531.618 23.6753 .3264 1778612.0 213799.1 930 1104 531.606 23.6726 .3266 1778612.0 213779.9 945 1104 531.589 23.6699 .3268 1778612.0 213762.1 a

E-1

VERIFICATION CLINTON POWER STATION ILRT TREND REPORT TIME AND DATE AT START OF TEST: 515 1104 1986 NO. END TOTAL TIME ANALYSIS MASS POINT ANALYSIS ,

PTS TIME MEAS. CALCULATED UCL CALCULATED UCL 2 530 .750 .750 99.000 .750 99.000 3 545 .787 .787 99.000 .787 .970 4 600 .852 .848 .960 .849 .960 5 615 .840 .857 .980 .852 .904 6 630 .823 .850 .974 .839 .874 7 645 .831 .849 .953 .838 .861 8 700 .838 .852 .941 .841 .858 9 715 .841 .854 .933 .844 .857 10 730 .835 .853 .926 .842 .853 11 745 .836 .852 .921 .842 .850 12 800 .846 .855 .918 .845 .853 13 815 .850 .857 .917 .849 .856 14 830 .838 .856 .914 .847 .854 15 845 .839 .855 .911 .846 .852 16 900 .837 .854 .908 .844 .849 17 915 .842 .854 .907 .844 .849 18 930 .843 .854 .905 .845 .849 19 945 .841 .854 .903 .845 .848 O

  • m i

E-2

, . - , , - - - - - -, - ~ ~ . - - - - - - . - - - - -

- - , , , , - - - -.,-e v . v---w--.--- - - - - - - - - - - -

v- --, - - - - - - , , -

VERIFICATION CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

MASS POINT ANALYSIS TIME AND DATE AT START OF TEST: 515 1104 1986 TEST DURATION: 4.50 HOURS TIME TEMP PRESSURE CTMT. AIR MASS LOSS AVERAGE MASS (R) (PSIA) MASS (LBM) (LBM) LOSS (LBM/HR) 515 531.895 23.7209 214099.6 530 531.874 23.7182 214082.9 16.7 66.9 545 531.854 23.7152 214064.6 18.4 70.2 600 531.839 23.7121 214042.6 21.9 76.0 615 531.818 23.7092 214024.7 17.9 74.9 630 531.800 23.7066 214007.9 16.8 73.4 645 531.783 23.7036 213988.5 19.4 74.1 700 531.764 23.7006 213968.8 19.7 74.8 715 531.751 23.6979 213949.6 19.2 75.0 730 531.730 23.6950 213932.1 17.5 74.5 745 531.712 23.6921 213913.1 19.0 74.6 800 531.697 23.6891 213892.1 21.0 75.5 815 531.681 23.6862 213872.2 19.9 75.8 830 531.662 23.6836 213856.6 15.6 74.8 845 531.647 23.6809 213837.7 19.0 74.9 900 531.632 23.6782 213819.7 18.0 74.7 915 531.618 23.6753 213799.1 20.6 75.1 930 531.606 23.6726 213779.9 19.2 75.2 945 531.589 23.6699 213762.1 17.7 ,75. 0 '

FREE AIR VOLUME USED (CU. FT.)' =1778612.0 REGRESSION LINE INTERCEPT (LBM) = 214100.5 SLOPE (LBM/HR) = -75.3 VERIFICATION TEST LEAKAGE RATE UPPER LIMIT = 1.066 VERIFICATION TEST LEAKAGE RATE LOWER LIMIT = .740 THE CALCULATED LEAKAGE RATE = .845 E-3

- . ~ _ .

VERIFICATION CLINTON POWER STATION ILRT LEAKAGE RATE (WEIGHT PERCENT / DAY)

TOTAL TIME ANALYSIS TIME AND DATE AT START OF TEST: 515 1104 1986 TEST DURATION: 4.50 HOURS TIME TEMP PRESSURE MEASURED (R) (PSIA) LEAKAGE RATE

~

515 531.895 23.7209 530 531.874 23.7182 .750 '

545 531.854 23.7152 .787 600 531.839 23.7121 .852 615 531.818 23.7092 .840 630 531.800 23.7066 .823 645 531.783 23.7036 .831 700 531.764 23.7006 .838 715 531.751 23.6979 .841 730 531.730 23.6950 .835 745 531.712 23.6921 .836 800 531.697 23.6891 .846 815 531.681 23.6862 .850 830 531.662 23.6836 .838 845 531.647 23.6809 .839 900 531.632 23.6782 .837 915 531.618 23.6753 .842 930 531.606 23.6726 .843 945 531.589 23.6699 .841

~

MEAN OF THE MEASURED LEAKAGE RATES = .832 VERIFICATION TEST LEAKAGE RATE UPPER LIMIT = 1.067 VERIFICATION TEST LEAKAGE RATE LOWER LIMIT = .742 THE CALCULATED LEAKAGE RATE = - .854 4

1 e

r E-4

VERIFICATION ILLINOIS POWER CO.

. CLINTON POWER STATION ILRT PROGRAM LEAK RATE

SUMMARY

Start Time:11- 4-88 5:15 End Timo:11- 4-86 9:45 Duration: 4.500 HOURS MASS POINT METHOD TOTAL TIME METHOD ELAPSED TEMP PRESSURE LEAK 95% LEAK 95% CTMT.

TI'. fE RATE UCL RATE UCL AIRMASS (HOURS) (DEG.R) (PSIA) (%/ DAY) (%/ DAY) (%/ DAY) (%/ DAY) (LBM)

.750 531.839 23.7122 .849 .960 .847 .959 214043 1.000 531.818 23.7093 .852 .904 .857 .980 214025 1.250 531.800 23.7067 .839 .874 .850 .974 214008 1.750 531.764 23.7007 .843 . .864 .857 .968 213969 2.000 531.751 23.6980 .845 .860 .855 .948 213950 2.250 531.730 23.6951 .843 .854 .852 .936 213932 2.500 531.712 23.6922 .842 .851 .852 .928 213913 2.750 531.697 23.6892 .845 .853 .854 .924 e 213892 3.000 531.681 23.6863 .849 .856 .857 .921 213872 3.250 531.662 23.6838 .847 .854 .856 .917 213857 3.500 531.647 23.6810 .845 .851 .855 .914 213838 3.750 531.632 23.6783 .844 .849 .854 .911 213820 4.000 531.618 23.6754 .844 .849 .854 .909 213799 4.250 531.606 23.6727 .845 .849 .854 .907 213780 4.500 531.589 23.6700 .845 .849 .854 .905 213762 E-5

VERIFICATION ILLINOIS POWER CO.

CLINTON POWER STATION ILRT PROGRAM TEST DATA Page 18 Date 11- 4-86 Time 9:45 Start Time: 5:15 Elapsed Time: 4.500 Hours Sample Interval:15. Minutes Start Date:11- 4-86 VOLUME CHANGE FROM DATA # DESCRIPTION VALUE FRACTION PREVIOUS SAMPLE 1 PRESSURE 1 23.995 PSIA .50000 .003 2 PRESSURE 2 23.999 PSIA .50000 .002 3 TEMPERATURE 1 72.030 DEGF .07000 .020 4 TEMPERATURE 2 71.960 DEGF .07000 .030 5 TEMPERATURE 3 71.900 DEGE .07000 .020 6 TEMPERATURE 4 72.010 DEGF .07000 .040 7 TEMPERATURE 5 72.130 DEGF .04600 .010 8 TEMPERATURE 6 72.380 DEGF .04600 .020 0 TEMPERATURE 7 72.450 DEGF .04600 .030 10 TEMPERATURE 8 72.420 DEGF .04600 .030 11 TEMPERATURE 9 72.400 DEGF .04600 .030 12 TEMPERATURE 10 66.250 DEGF .01000 .000 13 TEMPERATURE 11 71.730 DEGF .04600 .010 14 TEMPERATURE 12 72.070 DEGF .04600 .010 15 TEMPERATURE 13 72.110 DEGF .04100 .010 16 TEMPERATURE 14 71.660 DEGF .04100 .000 17 TEMPERATURE 15 71.220 DEGF .04100 .000 18 TEMPERATURE 16 71.050 DEGF .04200 .010 19 TEMPERATURE 17 69.900 DEGF .04200 .020 20 TEMPERATURE 18 71.150 DEGF .04200 .000 21 TEMPERATURE 19 73.600 DEGF .03300 .010 22 TEMPERATURE 20 73.150 DEGF .03300 .010 23 ' TEMPERATURE 21 72.620 DEGF .03300 .010 24 TEMPERATURE 22 72.100 DEGF .03300 .010 25 TEMPERATURE 23 71.520 DEGF- .00400 .000-26 TEMPERATURE 24 73.050 DEGF .00300 .020 27 HUMIDITY 1 86.110 %REL .14000 .090 28 HUMIDITY 2 85.070 %REL .14000 .100 29 HUMIDITY 3 84.530 %REL .11000 .090 30 ilUMIDITY 4 84.110 %REL .11600 .100 31 110MIDITY b 85.480 %REL .09400 .040 32 HUMIDITY 6 85.540 %REL .12800 .030 33 ilUMIDITY 7 90.570 %REL .12800 .060 34 ilUMIDITY 8 73.960 %REL .06900 .220 35 HUMIDITY 9 74.900 %REL .06900 .200 AlhMASS= 213763. LBM TEMP:71.9187 DEGF PRESSURE:23.6700 PSIA MASGPOINT TOTAL TIME METHOD METHOD LEAK RATE .845 %/ DAY .854 %/ DAY 95% UCI, .849 %/ DAY .905 %/ DAY

! E-6

e APPENDIX F Plots F

  • Plots -

Entire Test (Stabilization ILRT and Verification)

- Air Mass

- Temperature Pressure

- Vapor Pressure O

I CLINTON POWER STATION ILRT- turraz Tzsr l AIRMASS LBM X 1000 AND REGRESSION LINE

! 214.50 - vtarr1cirron

[- uar snaruanon l

! 214.34" su.81uunon N~ -

'~~~ s_ vearr1cirron

214.18

?

\

214.02" i

213.86"

.{

i 1 213.70 , , , , ,

,,,,,,,,r , , , ,

l .42l0 1102l TIME HOUES 945 1104 ,

1 START TIME DATE END TIME DATE

i i CLINTON POWER STATION ILRT - sNTras TsSr TEMPERATURE DEGREES F 77.500 STABILIZATION yea 1F1 citron ILRT STABILIZATION 4 76.300' VERIFICATION l

8 .

75.100' 7

N 73.900" 72.700 __

i .

~% i 71.500 . . . . . . . . . . . . . . . . . .  !

. 4'l0 1103 TIME HOUFS 945 1104  !

START TIME DATE END TIME DATE

l l

CLINTON POWER STATION ILRT - ENT1at rest l PRESSURE PSIA (DRY AIR)

STABILIZATION ILRT VERIFICATION STABILIZATION 23.920" VERIFICATION

' i 23.840' N

23.760~

N 23.680-23.600 . . . . . . . . . . . . . . . . . .

4

'.430 1103 TIME HOUES 945 1104 i

START TIME DATE END TIME DATE

i l

l CLINTON POWER ST ATION ILRT - zNT1Rt TzsT UAPOR PRESSURE PSIA

.330 STABILIZATION ILRT VERIFICATION STABILIZATION

.324

- /

VERIFICATION

! , .318

a.

{ .

] .312" ,f I

i l .306-

\4

\ i

.300 . ............. . . . .

.42l0 1102l TIME HOUFS 945 1104 START TIME DATE END TIME DATE i

1

Plots ..ILRT Air Mass Mass Point Leakage Rate and UCL Total Time Leakage Rate and UCL Weighted Average Temperature Weighted Average Pressure Weighted Average Vapor Pressure 2

e 9

e

If i

j CLINTON POWER STATION ILRT AIRMASS LBM X 1000 AND REGRESSION LINE 214.40 -

~~

s_ _

..~

214.32

~~. " " """

- ..'~ ._~ . ,

.~'

.' m.

7 214.24 _

o.75 t o u, -

214.16 .

.~

' ~

214.08' .

~~

214.90 , , , , , , , .

.900 11E13 TIME HOURS 400 1104 START TIME DATE END TIME DATE

CLINTON POWER STATION ILRT i MASS POINT LEAEAGE RATE AND UCL -

X/ DAY

.500 0.75 L a

.400 Uc':

l '...

$~~ - _

7 .300

-=_ -

==

i .200

.100'

.000 , , , , , , ,

.900 11EG TIME HOURS 400 1104 START TIME DATE END TIME DATE

i

, CLINTON POWER STATION ILRT TOTAL TIME LEAKAGE RATE AND UCL -

X/ DAY

.500 .

i 0.75 L a

!, .400 .

g 4

/  % __ --

uct

.300_

i M -

i ,

~

.200' B

l

.100" '

l

.000 . . . . . . .

.900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

1 l CLINTON POWER STATION ILRT TEMPERATURE DEGREES F - WEIGHTED AVERAGE 1

! 73.500

\.\ N 73.200' l

72 Oe 72.300-

! 72.000 , ,,....

! .900 1105: TIME HOURS 400 1104 l START TIME DATE END TIME DATE

w  %

mM g CLINTON POWER STATION ILRT PRESSURE PSI A (DRY A IR) - us1curto avtaice .

23.820 B

23.800 l 23.780 e .

l 23.760" 23.740- '-

23.720 , , , , , , ,

. 900 1103 TIME HOURS 400 1104
START TIME DATE END TIME DATE l

I CLINTON POWER STATION ILRT U APOR PRESSURE PSI A - us1curto Avsnics

.322 ./

.320 l

.3.1.5

.312"

.310.  !.

1900 1103 TIME HOUES 400 1104 START TIME DATE END TIME DATE

?

F 4

Plots - Verification

- Air Mass Mass Point Leakage Rate

- -Total Time Leakage Rate l -

Weighted Average Temperature Weighted Average Pressure

-- Weighted Average Vapor Pressure f

i 0,-

t

CLINTON POWER STATION ILRT - vER1rIcAT10N AIRMASS LBM X 1000 AND REGRESSION LINE 214.10%g- M- __

l i

214.00 ~~~

\

l _

~~

~~~ -_ _ UPPER LIMIT *

" ~

7 213.90 RMSSION LINE -

s,

._ \_~__,,__ , _

g ____ _ _

, e - . _-_

\ _

! 213.80"

  • LOWER LIMIT i

i -

~

213.70" ~- _.

  • LIMIT ON REGRESSION LINE
213.60 , , , ,
515 1104 TIME HOUES 945 1104 START TIME DATE END TIME DATE j -

3

CLINTON POWER ST ATION ILR - VERIFICATION '

MASS POINT LEAKAGE RATE -

X/ DAY

  • UPPER LIMIT

! 1.000 l

lj .900 l

l .800" f .

j

  • LOWER LIMIT i .700"
i .

! .600 ,

N LEAKAGE RATE

515 1104 TIME HOURS 945 1104~

i START TIME DATE END TIME DATE i

i CLINTON POWER ST ATION ILRT - VERIFICATION TOTAL TIME LEAEAGE RATE -

X/ DAY l

UPPER LIMIT

  • 1 .

1 l 1.000 .

7 .900 i U

.800" LOWER LIMIT *

.700" B

  • " N LEAKAGE RATE 600 ,

, 515 1104 TIME HOURS 945 1104 START TIME DATE END TIME DATE

1 CLINTON POWER ST ATION ILRT - vER1r1carron TEMPERATURE DEGREES F - WEIGHTED AVERAGE 72.225 B

l 72.164 72.102' \

!r l 72.041" 71.980"

\

! 71.919 . , , ,

! 515 1104 TIME HOUES 945 1104 l START TIME DATE END TIME DATE I

t CLINTON POWER ST ATION ILRT- vzarr1cirron .

PRESSURE PSIA (DRY AIR) - utronrzo Avsnicz 23.721~

23.711 i

23.701 3

w 23.690"

23.680" B

23.670 . . . .

515 1104 TIME HOUFS 945 1104 START TIME DATE END TIME DATE i

l

CLINTON POWER ST ATI ON ILRT - vER1r1 car 1ou U APOR PRESSLlRE PSI A - WEIGHTED AVERAGE

.327 ~

.326 7

i /'

l "

! .325 b / .

.324" -

.i

.324" f I -

/

i .323. / . , , ,

! 515 1104 TIME HOUES 945 1104 i START TIME DATE END TIME DATE

4 Plots - Data. Rej ection

- Report

- Weighted Average Vapor Pressure Vapor Pressure Humidity Sensor 3 e=

CLINTON POWER STATION ILRT DATA REJECTION REPORT TIME AND DATE AT START OF TEST: 1900 1103 1986 NUMBER OF DATA POINTS: 37 TIME CTMT. AIR STANDARDIZED (* > 5% REJ. LEV. = 3.04)

MASS (LBM) RESIDUAL (** > 1% REJ. LEV. = 3.36) 1900 214397. 1.658 1915 214391. 1.588 1930 214384. 1.271 1945 214377. 1.182 2000 214367. .425 -

2015 214359. .012 2030 214355. .287 2045 214350. .344 2100 214340. .284 2115 214330. .909 2130 214328. .352 2145 214322. .418 2200 214317. .341 -

2215 214308. .837 2230 214304. .624 2245 214298. .739 2300 214289. -1.191 2315 214285. -1.048 2330 214283. .468 ~

2345 214272. -1.276 0 214270. .818 15 214266. .635 30 214262. .372 45 214257. .288 100 214249. .687 115 214243. .711 130 214241. .119 145 214235. .269 200 214230. .199 215 214223. .329 230 214217. .454 245 214216. .246 300 214211. .350 315 214231. 4.126 **

330 214203. .801 345 214199. .926 400 214190. .524 F-17 a

CLINTON POWER STATION ILR - DATA REJECHON i U APOR PRESSl]RE PSI A - WEIGHTED AVERAGE

.322 /

.3 /'/

j  :

i

!=? .315 l

.312"

  1. ,/
.310 / , ' '

i 1900 1103 TIMI HOIJES 4$0 1.i.04 4

START TIME DATE END TIME DATE 4

4

t i

i CLINTON POWER STATION ILR - DATA REJECTION j DEWPOINT TEMPERATURE SENSOR 3 DEG. F -

i l

82.020 .

y 80.722 g' l

,/

! 79.424 .

!i; ..

! 78.126 -

! 76.828 -

4 I I I e 3 e I a

! 1900 1103 TIME HOURS 400 1104 l START TIME DATE END TIME DATE i

Plots - Individual Sensors

- Pressure Sensor 1 and 2 RTD 1 through RTD 24

- Humidity 1 through Humidity 9 l

i l

l

CLINTON POWER STATION ILRT PRESSURE SENSOR 1 PSIA 24.116 .

3 l

24.104 i "

24.092

?

a .

24.081-

)

24.069"

! 24.057 . , , , , , ,

.900 11EG TIME HOURS 400 1104 START TIME DATE END TIME DATE

CLINTON POWER STATION ILRT PRESSURE SENSOR 2 PSIA i

24.116 .\

j ..

24.104 .

s,.'\

24.093 .

~

24.082 .

24.070 .

1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

~

CLINTON POWER STATION ILRT TEMPERATURE SENSOR 1 DEGREES F 74.360s D

74.028 l

\

! 73.696 i

?

73.364" 4 .

I I 73.032"

~~N.__,

l 72.700 , , , , , , . ,

) .900 1103 TIME HOLIRS 400 1104 START TIME DATE END TIME DATE '

l

! CLINTON POWER STATION ILRT TEMPERATURE SENSOR 2 DEGREES F

\

l 74.310 .

i j ..

73.976 . N 73.642 h ju --

! 73.308

\'\

l

, , , , , , N 72.640 1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE

l; i

! CLINTON PONER STATION ILRT

! TEMPERATURE SENSOR 3 DEGREES F 74.220 \

\

i l 73.886 .

i s

! 73.552 i, \

i? .

I 73.218 72.884 . _N.

72.550 1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE

4 i

1 CLINTON POWER STATION ILRT l TEMPERATURE SENSOR 4 DEGREES F l

74.320 .

) . .

i 73.988 73.656 . N.

\  ? "

l u j 73.324 .

N i

72.992 .

1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE ,

l CLINTON POWER STATION ILRT TEMPER _ATLIRE SENSOR 5 DEGREES F l

! 74.430 .

)

74.098 .

73.766

!a 73.434 .

N 73.102 .

N 72.770 -

1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE

l i

CLINTON POWER STATION ILRT I

TEMPERATURE SENSOR 6 DEGREES F 74.690 .

( 74.356 . s

\

74.022 .

?

l U ..

! 73.688 i

! N l 73.354 .

! 73.020 1900 1103 ~ TIME HOURS 400 1104 l

START TIME DATE END TIME DATE I

i i

! CLINTON POWER STATION ILRT TEMPERATURE SENSOR 7 DEGREES F l 74.680 .

I 74.364 .

74.048

?

s ..

73.732 .

' 42' l . . . . . . .x i 73.100 l 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE l

l ,

i CLINTON POWER STATION ILRT '

i TEMPERATURE SENSOR 8 DEGREES F i N l 74.510 '

l 3 ,

l

) 74.220 .

l ..

l 73.930 (

2 - -

73.640 .

\

73.350 f I f f I

\ """-,

I I f 73.060 1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE

l l CLINTON POWER STATION ILRT i TEMPERATURE SENSOR 9 DEGREES F i

74.540 .\

l ..

l 74.244 .

j .. N_

l 73.948 i? . .

! 8 l 73.652 .

'N 73.356 . 'N i 73.060 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE i

! CLINTON POWER STATION ILRT TEMPERATURE SENSOR 10 DEGREES F 66.090 .

p 66.018 .

65.946 65.874 .

,s 65.802 .

1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

l

! CLINTON POWER STATION ILRT TEMPERATURE SENSOR 11 DEGREES F i \

72.470 i

i 72.364 -

l l 72.258 '

i

'\

!g" . .

72.152 .

72.046 .

N_

, , , , , , , i M

{ 71.940 1900 1103 ~ TIME HOURS 400 1104 END TIME DATE

, START TIME DATE

l l

CLINTON POWER STATION ILRT

! TEMPERATURE SENSOR 12 DEGREES F 73.000 .\

72.874 .

l 72.748 l2 1

m ..

l l

72.622 .

N 72.496 .

I I I I I I I I t 72.370 1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE

m J

CLINTdN POWER STATION ILRT i

TEMPERATURE SENSOR 13 DEGREES F

! 72.890 I

l 1

I i

72.780 -

i

! 72.670 ~

i l m -

! L - -

l~ 72.560 .

72.450

\

i j I I I I I I t t 7

! 72.340 l -

1900 1103 ' TIME HOURS 400 1104 l START TIME DATE END TIME DATE

I CLINTON POWER STATION ILRT TEMPERATURE SENSOR 14 DEGREES F 72.230 ,

72.148 1

72.066' -

h l 71.984" l B

1 71.902" 71.820 , , , , , , ,

.900 1103 TIME HOUFlS 400 1104 START TIME DATE END TIME DATE

l

) CLINTON POWER STATION ILRT TEMPERATURE SENSOR 15 DEGREES F

71.870 .

71.780 .

! __ \

i

71.690 '

i i 7 71.600 .

s 71.510 .

i 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

I I

] CLINTON POWER STATION ILRT j TEMPER _ATURE SENSOR 16 DEGREES F i

i 71.850 -

~

I i

71.730 -

i i

! 71.610 .

? ..

71.490 .

l l 71.370 .

71.250

, , , , , , , b l 1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE I

i i

CLINTON POWER STATION ILRT

! TEMPERATURE SENSOR 17 DEGREES F l 70.220 .  ;

i l 70.172 -

70.124 .

?

h. ~

~

la 70.076 .

i I 70.028 .

i 69.980 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE i

i

I

\

CLINTON POWER STATION ILRT

, TEMPERATURE SENSOR 18 DEGREES F i

j 71.410 .

i

! 71.364 .

4 i . .

71.318 71.272 i

( --

l 71.226 ,

i 71.180

' ' ' ' ' - . . ^!

1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE i

I CLINTON POWER STATION ILRT -

l TEMPERATURE SENSOR 19 DEGREES F 74.320 '

74.218 '

l

?

74.116 -

E .

74.014 -

l

.. \ -

73.912 .

i 73.810"-

1900 1103 ' TIME HOURS 400 1104 START TIME DATE END TIME DATE l

! CLINTON POWER STATION ILRT i TEMPERATURE SENSOR 20 DEGREES F

! 73.860 .

i 73.756 .

\ ~ ~

73.652 I

73.548 m

73.444 .

, , , , , , , ,T 1900 1103 TIME HOURS 400 1104 j, START TIME DATE END TIME DATE i

i

O

! CLINTON POWER STATION ILRT l TEMPERATURE SENSOR 21 DEGREES F 73.300 .k, j . .

I 73.208 .

i 73.116

!~

73.024 .

72.932 .- \ '

72.840 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

l l

CLINTON POWER STATION ILRT TEMPERATURE SENSOR 22 DEGREES F i

72.650 l

l . .

72.570 .

l ~

72.490 .

\

g ..

l 72.410 .

s 1

j ..

72.330 .

, , , , , , , , N i 72.250

1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE I

CLINTON POWER STATION ILRT

\

TEMPERATURE SENSOR 23 DEGREES F 72.020 71.944 .

I 71.868 .

m --

5 71.792 . \,

71.716 i

71.640 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

l l

CLINTON POWER STATION ILRT TEMPERATURE SENSOR 24 DEGREES F 73.250 i .

i

! 73.200

/

! 73.150

!?'

/\

" \ /

i 73.100 ,_J j .

/

73.050"

! 73.000 , , , , , , ,

) .900 11EG TIME HOUES 400 1104 START TIME DATE END TIME DATE

CLINTON POWER STATION ILRT DENPOINT TEMPERATURE SENSOR 1 DEG. F 83.820 e l

' /

83.394 ,

82.968 i 7 .

) 82.542 ,[

l .

! 82.116" 81.690. .. . . . . . . .

.900 1103 TIME HOUFS 400 1104 START TIME DATE END TIME DATE l .

i i

CLINTON POWER STATION ILRT DEWPOINT TEMPERATURE SENSOR 2 DEG. F 82.830 .

1 i

! 82.446 '

82.062 '

6 l 81.678 .

I i

81.294

/,

/, , , , , , ,

! 80.910 i

1900 1103 ~ TIME HOURS 400 1104 l START TIME DATE -

END TIME DATE i

! CLINTON POWER STATION ILRT

! DEWPOINT TEMPERATURE SENSOR 3 DEG. F 82.020 l

l l

81.452 I

80.884 ,

2 m

/

80.316 /

79.748- '

79.180 / ' '

l .900 1103 TIMN H6 HRS 4$0 1.'.04 1

i START TIME DATE END TIME DATE

i CLINTON POWER STATION ILRT l DEWPOINT TEMPERATURE SENSOR 4 DEG. F l 82.020 [

81.570 .

.. /

81.120 .

?

g --

80.670 '

f ,

80.220

! 1 79.770./

i l 1900 1103 TIME HOURS 400 1104 .

START TIME DATE END TIME DATE l

CLINTON POWER STATION ILRT

! DEWPOINT TEMPERATURE SENSOR 5 DEG. F 84.000

82.782 .

l, 81.564 .

'e '

i i

80.346 .

79.128 .

I I I I I I I I

. 77.910 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

i l

I CLINTON POWER STATION ILRT .

I DEWPOINT TEMPERATURE SENSOR 6 DEG. F '

_~

84.790 f 83.820 '

l 82.850 .

!? '

lM . .

81.880 .

i 80.910 .

79.940 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

_m. . _ _ _ _ . _ _ _ , _ _ _ . _ _ . . _ _ _ _ _

CLINTON POWER STATION ILRT DEWPOINT TEMPERATURE SENSOR 7 DEG. F

89. 78 i

88.466 .

lI '

l" ..

l 87.754 '

I l

87.042 .

86.330 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE

~

i

! CLINTON POWER STATION ILRT l DEWPOINT TEMPERATURE SENSOR 8 DEG. F

_s -

67.040 B l

62.632 .

[

. . t 58.224 D

?

1 i

i

53.816 '

49.408 .

/ , , , , , , , ,

t 45.000~

i 1900 1103 TIME HOURS 400 1104 START TIME DATE END TIME DATE i

I i

CLINTON POWER STATION ILRT

~

l DEWPOINT TEMPERATURE SENSOR 9 DEG. F 68.390 .

64.200 D 60.010 l

E --

, / '

i I

55.820 51.630 . ,

t I I E R R R I 47.440, l 1900 1103 TIME HOllRS 400 1104-l START TIME DATE END TIME DATE

l l

1 I

l I

i I

e Appendix G Instrument Selection Guide Calculations i

E i

1-1

ISG CALCULATION (ANSI /ANS 56.8 - 1981)

CALIBRATION DATA

  1. OF SENSORS SENSITIVITY (E) REPEATABILITY (r)

TEMPERATURE (T) 24 0.0100 deg. F 0.0100 deg. F PRESSURE (P) 2 0.0003 psia 0.0002 psia VAPOR PRESS (Pv) 9 0.5000 deg. F 0.1000 deg. F Length of Test (t) 9.00 hrs .

Test Pressure (P) 9.66 psig == 24.06 psia Test Temperature (T) 532' deg. R From Steam Table 0.01114 psi /deg. F (at 66.5 deg. F)

La 0.6500 wt%/ day INSTRUMENT MEASUREMENT ERRORS eT = [(ET) + (rT) ) /[# of sensors]

eT = 0.0029 deg. F eP = [(EP) + (rP) ] /[# of sensors]

eP = 0.0003 psia ePv = [(EPv) + (rPv) ) /[# of sensors]

erv = 0.0019 psia INSTRUMENT SELECTION GUIDE ISG = 2400/t[ 2(eP/P) + 2(ePv/P) + 2(eT/T) ]!

ISG = 0.0301 we%/ day 25% of La 0.1625 wt%/ day G-1

Appendix H Drywell Bypass Leakage Rate Test

DRYWELL BYPASS LEAKAGE RATE TEST NOVEMBER 4, 1986 START: 19:31 END: 23:41 t (HRS)*:

4.167 I. WEIGHTED AVERAGE DRYWELL TEMPERATURE INITIAL TEMPERATURE Ti VOL FRAC (Ti+460) X VFi T19 = 73.80 0.033 17.61540 T20 = 73.43 0.033 17.60319 T21 = 72.97 0.033 17.58801 T22 = 72.51 0.033 17.57283 T23 = 72.38 0.004 2.12952 T24 = 72.74 0.003 1.59822 SUMS == VFi = 0.139 Ti, IVFi = 74.10717 WT AVG T1 = 533.15 DEG R OR 73.15 DEG F FINAL TEMPERATURE Ti VOL FRAC (Ti+460) X VF1 T19 = 74.14 0.033 17.62662 T20 = 73.75 0.033 17.61375 T21 = 73.29 0.033 17.59857 T22 - 72.85 0.033 17.58405 T23 = 72.73 0.004 2.13092 T24 = 72.85 0.003 1.59855 SUMS == VFi = 0.139 Ti,2VFi = 74.15246 WT AVG T2 = 533.47 DEC R OR 73.47 DEG F II. ABSOLUTE DRYWELL PRESSURES (MENSOR QM-2040, P2, QPS-3401)

INITIAL FINAL P1 = 57.589 (COUNTS) P2 = 56.724 (COUNTS)

M= 0.3035544 M= 0.3035544 C= -0.046 C= -0.046 P1 = 17.435394 PSIA P2 = 17.17282 PSIA III. DRYWELL LEAKAGE RATE CALCULATION (COMPENSATED FOR WEIR LEVEL)

L =

Pl[V+(P1 x 2.31 x 473)] -

P2[V+(P2 x 2.31 x 473)] x Ts T1 T2 60tPs L = 17.4354[245,323+(17.4354 x 1092.63)] - 17.1728[245,323+(17.1728 x 1092.63)]

533.15 533.47 528 X 882(4.167)

Lg= 20.77 SCFM H-1

a Appendix I Type B and C Leakage Rate Test Results I

t

- , , , - , , . , . . - - - _ , , - , ,,,,,,-_.,..---y, . . , , ... -- , - -. , - - - ,.n-,,--.- - -

\;

e Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance Number Test accm seem IMC-1 Equipment Hatch B 0 , 0 IMC-2 Personnel Lock B 40 10.28 (Lower)

IMC-3 Personnel Lock B 40 10.28 (Upper)

IMC-4 . Fuel Transfer Tube B 100 25.7 1MC-5 Main Steam "A" C* 2322* 208*

IMC-6 Main Steam "B" C* 198* 9.A*

IMC-7 Main Steam "C" C* 1723* 28.3*

IMC-8 Main Steam "D" C* 151* 9.4*

IMC-9 Feedwater "A" C 70 10.28 <

IMC-10 Feedwater."B" C 80 20.56 IMC-14 RHR S/D Suet. C 180 5.14 1MC-15 RHR "A" Injection C 50 10.28 IMC-16 RHR "B" Injection C 4020 ~ 206.14 1MC-17 RHR "C" Inj ection C 40 10.28 iMC-18 RHR "A"1 Test C 270 25.7 1MC-19 RHR "C" Test C 25 10.28 1MC-20 RHR "B" Test C 5 10.28

1MC-24 RHR "A" Press Relief C 20 5.14 i

l IMC-26 RHR "B" Press Relief C 20 5.14 1

IMC-27 RHR C** 2510** 202**

  • MSIV's not included in .6 La
    • Included with IMC-16 i

l l

, I-1 thru I-9

Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance Number Test seem scen 1MC-31 RHR HX Relief C 20 2 1MC-33 HPCS Test Line C 40 5.14 1MC-34 Suppression Pool C 139.4 7.14 Cleanup Suct.

IMC-35 HPCS Injection C 40 10.28 IMC-36 LPCS Injection C .70.2 4 1MC-41 RCIC C. 40 10.28 IMC-42 RCIC HD. Spray C 620 27.64 1MC-43 RCIC Turb Sup. C 40 10.28 1MC-44 RCIC Vacuum C 2020 55.28 1MC-45 Main Steam Drain C 740 27.64 IMC-46 Component Cooling C 1240 27.64 Water Sup.

IMC-47 Component Cooling C 285 10.28 Water Ret.

IMC-48 Shutdown Service C 20 5.14 Water "A" 1MC-49 Breathing Air C 95.5 12 1MC-50 Makeup Condensate C 182.6 2 1MC-52 Fuel Pool Cooling & C 430 5.14 Cleanup Sup.

1MC-53 Fuel Pool Cooling & C 110 10.28 Cleanup Ret.

IMC-56 Fire Protection C 60 10.28 IMC-57 Instrument Air C 1702 40 1-2 thru I-9

v ->  %

d Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance-Number 3 Test accm scca IMC-58 InstrumentAirBotl C 2500 201 1MC-59 Service Air C 230 5.14 1MC-60 RWCU Suct. C 1660 22.51 '

1MC-61 RWCU Ret. C 40 10.28

'1MC-62 Hydrogen Recombiner C 70.1 4 1MC-63 CRD Sup. C 760 22.5 1MC-64 RWCU Ret. C. 45 10.28 1MC-65 RWCU To Radwaste C 20 5.14 1MC-67B Containment C 60 5.14 Fressurization 1MC-68 (1 or 5) Process Sampling C 25 5.14 1CM-68 (2 or 5) Process Sampling C 20 2 1CH-68 (3 or 5) Process Sampling C 25 5.14 1CM-68 (4 or 5) Process Sampling C 20 2 1MC-68 (5 of 5) Process Sampling C 20 2 1MC-69 Ctat. Equipment C 50.9 2 Drain IMC-70 Ctat.-Floor Drain C 70 5.14 IMC-71 Hydrogen Recombiner C 100 10.28' 1MC Hydrogen Recombiner C 1102 25.14

-1MC-78 Component Cooling C 5 4 To RR IMC-79 Supression Pool C 40 4 Cleanup Rec IMC-81 Fire Protection C 165 10.28 i

I-3 thru I-9

Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance Number Test seem seem IMC-82 Fire Protection C 805 27.64 IMC-85 Cycled Condensate C 2040 202 1MC-86 RWCU Letdown C 50 5.14 1MC-87 RHR C* 410.03* 2.02*

IMC-88 Component Cooling C 140 10.28 Water From RR IMC-101 Containment HVAC C 2170 27.64 Sup.

1MC-102 Drywell Purge C 1420 27.64 1MC-103 Containment Chill 180 5.14 Water Sup.

IMC-104 Containment Chill C 80 5.14 Water Ret.

IMC-106 Containment HVAC C 60 10.28 Exh.

IMC-107 Drywell Cooling "B" C 110 5.14

~

Chill Water Sup.

1MC-108 Drywell Cooling "B" C 150 5.14 Chill Water Ret.

1MC-109 Drywell Cooling "A" C 2800 201 Chill Water Sup.

IMC-110 Drywell Cooling "A" C 20 5.14 Chill Water Ret.

'1MC-113 Containment HVAC C 1640 27.64 Sup.

IMC-116 Standby Liquid C 60 6 Control

  • Included with IMC-15 I-4 thru I-9

Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance Number Test scem seem IMC-151 (1 of 2) Nuclear Boiler C 20 5.14 1MC-151 (2 of 2) Containment C 20 5.14 Monitoring IMC-152 (1 of 3) ILRT C 36.8 2 Instrumentation IMC-152 (2 of 3) ILRT C 30.2 2 Instrumentation IMC-152 (3 of 3) ILRT - C 62 2 Instrumentation IMC-153 (1 of 2) Containment C 20 2 Monitoring IMC-153 (2 of 2) Containment C 40 4 Monitoring IMC-160 Nuclear Boiler C 20 5.14 1MC-166 Hydrogen Recombiner C 144.3 4 1MC-169 (1 of 2) Containment Purge C 368 20 1MC-169 2 of 2) Containment Purge C 340 5.14 IMC-173 (1 of 2) Containment Monitoring C 5.45 0.2 1MC-173 (2 of 2) Containment Monitoring C 138.2 2 1MC-203 Containment Monitoring C 30 5.14 1MC-204 Shutdown Service Water C 70 5.14 B" Ret IMC-205 Shutdown C 20 5.14 Service Water "B" Sup.

1MC-206 Instrument Air C 1560 22.5 1MC-208 Shutdown Service C 40 10.28 Water "A" Ret.

I-5 thru I-9

Local-Leakage Rate Test Results Penetration- Description Type Leakage Rate Tolerance Number Test seca scen 1MC-210.(1 of 5)- Process Sampling -C 20 5.14

-1MC-210 (2 of 5) Process Sampling C 20 2.0 1MC-210 (3 of 5) Process Sampling C 2.54 2 1MC-210 (4 of 5) Process Sampling C 4.43 2 1MC-210 (5 of 5) Process Sampling C 54.7 2 1PIB-1 RR "A" B 0 0 1P2B-1 RR "B" B 0 0 1PIB-2 Balance of Plant B 0 0' 1PIB-3 Balance of Plant B 0 0 1P2B-3 Balance of Plant B 0 0 1P1B-4' Balance of Plant B 0 0 1P2B-4 Balance of Plant B 0 0 1 PIE-1. Engineered Safety 1 B 0 0

, IP2E-2 Engineered Safety 2 B 0 0 IP2E-2 Engineered Safety 2 B 0 0 i

IC1B-1 Information B 0- 0

! 1C2B-1 Information B 0 0 I

IC1B-2 Information B 0 0 IC2B-2 Information B 0 0 f

l 1C1B-3 Information B 0 0 l

IC2B-3 Information B 0 0' 4 1CIE Reactor Protection B 0 0

. System 1 l

I-6 thru I-9 l

[

Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance Number. Test seem seem IC2E Reactor Protection B 0 0 System 2 1C3E Reactor Protection B 0 0 System 3 1C4E Reactor Protection B 0 0 System 4 1K1E-1 Control Rod B 0 0 Indication 1 1K2E-1 Control Rod B 0 0 Indication 2 1K3E Instrument 3 B 0 0 1K4E Instrument 4 B 0 0 1K1B-1 Instrument B 0 0 1K2B-3 Instrument B 0 0 1K1E-2 Instrument-1 B 0 0 1K2B-1 Instrument B 0 0 1K1B-2 Instrument B 0 0 1K2B-2 Instrument-1 B 0 0 1 KIN Neutron Monitoring B 0 0 System 1 1K2E-1 Instrument 2 B 0 0 1C2E-2 Engineered Safety 2 B 0 0 IK4N Neutron Monitoring B 0 0 1PIB-5 Balance of Plant B 0 0 1 PIE-2 Engineered Safety 1 B 0 0

.1P2E-3 Engineered Safety 2 B 0 0 I-7 thru I-9

7-.

Local Leakage Rate Test Results Penetration Description Type Leakage Rate Tolerance Number Test seem seem 1K2N Neutron Monitoring B 0 0 System 2 1K2N Neutron Monitoring B 0 0 System 3 1K1B-3 Testing Instrument B 0 0 1KlB-4 Testing Instrument B 0 0 ISP-1 Spare B 0 0 1KlE-3 Instrument 3 B 0 0 ISP-3 Spare B 0 0 LEE 46E Communication B 0 0 Lighting IEE47E Communication B 0 0 Lighting IEE48E Communication B 0 0 Lighting

-LEE 49E Communication B 0 0 Lighting

\

l.

l l

i I-8 thru I-9 l.

m- w - -v w e vr- g vy , g -ay----,

v -->4wg4 -n ---,r-yw- n- -- y-< y ,w"--

Local Leakage Rate Test Results Summary Leakage Rate Tolerance seem seem Total B + C 34,905.42 500.27 (excluding MSIV and water tests)

Total MSIV 4394 ---

Total Water Tests 3.758 GPM ---

SUMMARY

OF HYDRAULIC LEAKAGE SYSTEM LEAKAGE (GPM) TOLERANCE (GPM)

RHR A System 2.878 GPM 0.247 RHR A Suction 0.078 GPM 0.015 '

RHR B System 0.090 GPM 0.0078 RHR B Suction 0.078 GPM 0.015 RHR C System 0.078 GPM 0.015 RHR C Suction 0.078 GPM 0.015 LPCS System 0.156 GPM 0.03 LPCS Suction 0.078 GPM 0.015 HPCS System 0.078 GPM 0.0078 RCIC System 0.156 GPM 0.03 RCIC Suction 0.078 GPM 0.015 RCIC Exhaust 0.10 GPM 0.015 3.758 GPM I-9 thru I-9

U 600813 L30-87(02- 02) 1A.120 ILLIN0/8 POWER COMPANY CLINTON POWER STATION. P.O. Box 678. CLINTON. ILLINOIS 61727 February 2, 1987 Docket No. 50-461 Director of Nuclear Reactor Regulation Attention: Dr. W. R. Butler, Director BWR Project Directorate, No. 4 Division of BWR Licensing U.S. Nuclear Regulatory Commission Washington, D. C. 20555

Subject:

Clinton Power Station Appendix J - Reactor Containment Building Integrated Leakage Rate Test

Dear Dr. Butler:

In accordance with 10CFR50, Appendix J, attached is the Reactor Containment Building Integrated Leakage Rate Test Final Report for Clinton Power Station. If you have any questions on this report, please contact me.

Sincerely yours,

. s F. A. Sp nge erg Manager - Licensing and Safety DWW/cke Attachment cc: B. L. Siegel, NRC Clinton Licensing Project Manager NRC Resident Office Regional Administrator, Region III, USNRC Illinois Departnent of Nuclear Safety D

Of, I \