ML20137M267

From kanterella
Jump to navigation Jump to search
Rev 0 to Tray Cover Exemption for Safety Trays Under Non-Safety Raceway
ML20137M267
Person / Time
Site: Clinton 
Issue date: 01/08/1985
From:
SARGENT & LUNDY, INC.
To:
Shared Package
ML20137M160 List:
References
19-BD-13, 19-BD-13-R, 19-BD-13-R00, NUDOCS 8601280229
Download: ML20137M267 (2)


Text

.'

o Cales For Trav Cover h m tion for Cale. No. 19-80-13 SARGENT hlUNDY

- a womeemet i

a., O oe.ol-os-as sacetv Travs ender uen-saf ety na cemv c -- c a o o X

9,,,,_g,i,,ed l

N on-Lf ety-R eisted

%e 1

of 2

F 'o*'ed hv f M M + /. a /

c cex:: - y,.; -

C:et Illinoin Po er cc-une

~

~

n,--.ohv N [S w at c.

/

cr./-2 M i no,,n eltneon

/t.ft b M t Date /-b M Noi No.

4536-00 Eamo No Apotoved by

~' % ~PQ UIBG 'DIVISIQ;:~ NED FIIE M).: 19BD

~~

E

Purpose:

_ The purpose of this analysis is to demonstrate.that Class JE. cables

_ routed in uncovered trays which are located under non-Class.lE sable in uncovered solid bottco trays or conduit do not require covers _

_ for internally generated faults / fire provided a one inch minimum t..._._ __separa tion is maintained.

Separation requirements for external _

.ha ards are not. addressed.in_this analysis.'

I l

i l

\\

\\

_. _. _.i_ i__ ; _ i 8

l lon-Cla s s_'. II. L,i i

i i

/ igure: _._._.

I 9 l i

_. Raceway _..

\\

' " w

  • n M um I _.

I i

i Class 1E __ p. _:. : - - _..

L_. _ -

L.

b. _.. _ __.

_. Cables C U ' ___

A hC.P c i L _._ _

. _.. _ _0,. N__; C__ O N 1 nC4 b.

i g __

__._1 i i

I I

I l

_lua tification:. _,. _._ i,.__.

j i

I l

_ Hegulatory_Gulde_1.754278_ and IEEE_.184-1374l_addrless l

aepara tion._!_,

i I

i

__.dne.to.toth internally _ generated. fire.and_ external._hazarda..__.Since

__ external _ha:ards..iincludind_ehposurc 11'rek1_ N abd$csbed n

7 i

i specific _ studies _with. specific Iequiraments l this;_ analysis _wi1Lhe L i

i i

i j

_. _. limi'ted_to_ addressing.'. internally g.cnersted.f'auits2f dres

__L I j

I I

l l

l l

I k

i l

t

}

l l

3 e

i 6

I i

i

_ __._for__danage po tential limited..to[ interna'lly. generated _f.ailures tor'

=

r

. f aults IIII_3 8 h117.4,_Sec tion _.5. L1.1.dic tates_.that_.aLminimum ___ '

a i

i t

i i

t

. _s epara tion _ dis tance _can be. established by. analysis _o, f_',the. propo sed.}.._,

e i

i r

i I

'_ca.ble _ina,tallation d Q.therwise a3.er.ical saparation of_thrne ' f ecAL_._

i i

i

.i i

i i

i i

_in_.ca hl e_.;sp r.e a ding _'ar e s s_.a nd..f iv e _l e e.t.in ' g.cn c r a lLp la rtt_a ran s._ishall _ ;

I I

l ha._ma i n t Ained_.p er. Sec tion _.5. L3 Land K 114 t

I

_' i;j' l

l I

t l

=

!I l

I 1

l i

il l

l l

! ']l i

J-1 i

i l

~

FOR4HEEXNT l l l i

T '-- - '.

l 1

l l

l i

i i

i

..L_

i i

t i

'l l

l l

l I

0601280229 060124

~ ~ ~ ' " " ~ ~ ~ ~ ~

~ ~ ~ ~ ~ ' ' ^ ~ ~

'.^

PDR ADOCK 05000461

'""~~

A PDR

c.ic.N. 19-ao-13 cm, r w c,v r,e-., e n., enr SA.9 GENT k LUNDY 3,,,3.

y., p.,ge, % _g3,e y p y,,wav R e-0 o= 01-08-es

...i~.....

y l Lfety-Reisted Non-Lfetv-Related f59e 2

of 7 c-caoc cent Illinois Power Comcany Prepared hv Date l

Prciect C1inton R eviewed bv Date l

Aaoroved by Dets l

Prei. No.

4536-00 Eamo No.

Justification: (continued)

The cable which is installed in.the trays on the Clinton Project, i_s _'

._ IEEE-383 qualified _ fire retardant cable.

Also, the_ design _ basis _ is_.!

.that trays will not be. filled above the side rails.

Whenever the I

r.aceways _(i.e. conduit or solid bottom uncovered tray) with only. _

_ non-Class lE cables pass over. an uncovered tray with Class lE

.. _ cables, t.he_results of an. internally _generat.ed_ fault 4 fire in the h _..._ essential _ tray can _only aff ec_t _that _diyj.sion_of _the_ cables _. and.t_h_e.__}

[_ ___non-Class' lE cables.which are not required.f_orisafeishutdown.'

I

.i Internallv_Senera ted f aultsHir_es_inithe__rion'-esse' tial racewa[will n

i i

only. aff ect_the non-. Class _lE _ cabling _because heat f rom internal _ly; l

I p.__

.. generated faults / fires _will rise _;thus.not_aff ecting_the cables below

, Covers _pn non-Class lE_ __l

[. _._prov.ided.a one _ inch.. air _ gap _ is_Uti).ited..

i

_ __.. cable _ tray will_not. provide _any.. protection _forlthe Claas _1_E' tray _ '

l l

-. _ _ - -._ -_-_' a _ _ t l

I I

beneath,. -

i l

1 t

- eJ_ l

{

l l

__x

( - _ _... _ -

3ased._on_the.abov.e,._ tray _c.gvers 'gp..ne. ither_ the ! tr.aydvi[th_Cla.ss lE f cabl.esnor__the_traywithnon-Class'lEcablebrk_r!equired'when!

I i

-- _._non-Class lE raceways.are._over_ Claha,lE. uncovehad Aray_s And_t here is l

- -~

i I

l l

l a mi.n#;um_of 1" se_p.ar_ation.

i I

i i

I l

l l

l l

l l

}

l i

I I

Fe I ] ]l I

j_

I l

l i

I j

_B e' er e_nc e_;_

I I

t

{}

l t

l l

l i 1.

'IEEE !38k-l'974 I

i I

i i

3

_ ___ l.__ ~.'inal_Saf e.ty., Analy s is_Ref or_t_ RSAR_)' _ A:.endment il5!

l I

a 3.

WEIq-Oll53 - Safety Evaluath.on ReporLKlinton) '

I i

i l

o i

i i L __NEC_Regulktory _, Guide _1.7E_.119.78 i

[l I

1 Ll I

i i

i l

1 i --_

- _L' I

I I

i t

i i

l l

i i

2 i

. k J.d_. _

[M._

_icen u,,e - -_[_q.

b I

l

/-

I i

}

.. [_.b,. m ' _. _

I l

l l

l i

i i

i l

i I

+

i j

t i

gg i

i i

i J, 2._--((. 7 _, _ !

I I

l i

l i

m!

l t

6 i,

i, i

i i

i

+

j i

1 j

i i

i i

I 1

i

_.