ML20196K999

From kanterella
Jump to navigation Jump to search

Forwards RAI Re Licensee 990621 Request for Amend to FOL R-57 for Omaha Veterans Admin Medical Ctr Triga Research Reactor.Response Requested within 30 Days of Date of Ltr
ML20196K999
Person / Time
Site: 05000131
Issue date: 07/06/1999
From: Alexander Adams
NRC (Affiliation Not Assigned)
To: Claassen J
DEPT. OF VETERANS AFFAIRS MEDICAL CENTER, OMAHA
References
TAC-MA5960, NUDOCS 9907120248
Download: ML20196K999 (4)


Text

p , W-u 6, M Mr. John P. Claess n Reactor Manager Veterans Administration Medical Center 4101 Woolworth Avenue Omaha, Nebraska 68105-

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA5960)

Dear Mr. Claassen:

1 We are continuing our review of your request for amendment of Facility Operating License No. R-57 for the Omaha Veterans Administration Medical Center TRIGA Research Reactor which you submitted or June 21,1999. During our review of your amendment request, l

questions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed Request for Additional Information within 30 days of the date of this letter. Following receipt of the additionalinformation, we will continue our evaluation of your request. ,

in accordance with 10 CFR 50.30(b), your response must be executed in a signed original l under oath or affirmation. If you b::ve any questions regarding this review, please contact me at (301) 415-1127.

Sincerely, ORIGINAL SIGNED BY:

Alexander Adams, Jr., Senior Project Manager j Events Assessment, Generic Communications and Non-Power Reactors Branch 1 Division of Regulatory improvement Programs l Office of Nuclear Reactor Regulation I Docket No. 50-131

Enclosure:

As stated h' h cc w/ enclosure: j See next page-Dl6TRIBUTION:

E-MAIL HARD COPY PDoyle Pisa?: 1 Dock,et File 50-131 . Marsh i TDragoun MMendonca PUBLIC AAdams l TMichaels ' WEresian OGC (015-B18)~ EHylton /

SHolmes CBassett ' DMatthews REXB r/f I l

" "I 9907120248 990706 AO PDR P

ADOCK 05000101 PDR r\

M R .LA RE REXB:BC h LMarsh AA s on '

7/ /9 7/ / /99 7/ 6 /99 OFFICIAL RECORD COPY DOCUMENT NAME: G:\REXB\ ADAMS \RAl-MA5960 j

r, <-

e

, a%g i

p 4 UNITED STATES

!

  • E NUCLEAR REGULATORY COMMISSION I , f WASHINGTON, D.C. 2006EMm01

't, . . . . . p July 6, 1999 Mr. John P. Claassen Reactor Manager Veterans Administration Medical Center 4101 Woolworth Avenue Omaha, Nebraska 68105 I

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA5960)

Dear Mr. Claassen:

We are continuing our review of your request for amendment of Facility Operating License No. R-57 for the Omaha Veterans Administration Medical Center TRIGA Research Reactor which you submitted on June 21,1999. During our review of your amendment request,

nuestions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed Request for Additional Information within 30 days of the date of this letter. Following receipt of the additional information, we will continue our evalJation Of your request, in accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. If you have any questions regarding this review, please contact l

me at (301) 415-1127.

< l Sincerely, j l

      • b / .

Alexander Adams, Jr., Seni Project Manager l l

Events Assessment, Generic Communications and l Non-Power Reactors Branch Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No. 50-131 I

Enclosure:

As stated j cc w/ enclosure:

See next page i

j

'w -

-9 Veterans Administration Docket No. 50-131 Medical Center -

cc:

Mayor City of Omaha Omaha, NB 68102 Mr. John P. Claassen Reactor Manager / Supervisor Omaha Veterans Administration Medical Center 4101 Woolworth Avenue Omaha, NB 68105 Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of F!orida i Gainesville, FL 32611 j Cheryl Rogers, Program Manager for Radioactive Matenam Department of Health & Human Services l 301 Centennial Mall South l P.O. Box 95007 Lir.coln, NE 68509-5007 l

i l

~

%e T

e ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION

{

OMAHA VETERANS ADMINISTRATION MEDICAL CENTER DOCKET NO. 50-131

1. In accordance with the regulations in 10 CFR 50.30(u), please resubmit your ,

application for amendment as a signed original undcr oath or affirmation.

{

2. Please submit replacement technical specification (TS) pages that reflect the changes I you are proposing for the TSs. Use vertical bars in the margin of the TS pages to indicate areas of change.
3. Please provide a safety analysis for each of your proposed changes or additions to  !

the TSs. The analysis should clearly explain what the change or addition you want to make is and provide a justification as to why the chrnge is acceptable.

4. One of your proposed changes would allow postponement of surveillances if the ,

react r is shut down for periods of time exceeding the surveillance interval. Please provide a justification for those surveillances that this postponament would apply to.

5. It appears that your proposed TS 4.5 is a substitute surveillance for when contic! rod or fuelinspections cannot be performed. Explain how you can establish baseline measurements and see long term trends if the analysis is only performed when the reactor is shut down for a period of time long enough for a surveillance to come due.

l l

(-