Text
}
'\\-
MAY 2 01987
In Reply Refer To:
Docket:
50-131/87-01
Omaha Veterans Administration Medical Center
ATTN:
R. L. Turcotte, Hospital Director
4101 Woolworth Avenue
Omaha, NE
68105
Gentlemen:
This refers to the inspection conducted by Mr. R. E. Baer of this office during
the period April 13-17, 1987, of activities authorized by NRC Operating License R-57
for Omaha Veterans Administration Medical Center TRIGA Research Reactor, and to
the discussion of the findings with you and other members of your staff at the
conclusion of the inspection.
Areas examined during the inspection included:
reactor operations, physical
security, safeguards, transportation of radioactive materials and emergency
planning. Within these areas, the inspection consisted of selective examination
of procedures and representative records, interviews with personnel, and
observations by the NRC inspector.
The inspection findings are documented in
the enclosed inspection report.
During this inspection, it was found that certain of your activities were in
violation of NRC requirements.
Consequently, you are required to respond to
this violation, in writing, in accordance with the provisions of Section 2.201
of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal
Regulations.
Your response should be based on the specifics contained in the
Notice of Violation enclosed with this letter.
The response directed by this letter and the accompanying Notice is not subject
l
to the clearance procedures of the Office of Management and Budget as required
by the Paperwork Reduction Act of 1980, PL 96-511.
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
Sincerely,
jg1
ORIGINAL SIGNED BY:
870SE]h1870
g OSO
DR
Lawrence A. Yandell, Chief
g
Radiological Protection and Safeguards
Branch
Enclosures:
(see next page)
BMurray/
C:FRPS
C:RPSB
IV:FRPS
LAYandel
EBaer:dp
6/f/87
( /g/87
f/rfe /87
i ;
ly
r
b-
'
'
'
i
'I
,3'
Omaha Veterans Administration
-2-
Medical Center
- Enclosu~res:
1.
Appendix A - Notice of Violation
-2.
' Appendix B - NRC: Inspection Report
-
S0-131/87-01
cc:
Nebraska-Radiation Control Program Director
bec to DMB (IE01)
bec distrib. by' RIV:
- RPB
DRSP.
- MIS System
R. D. Martin, RA
- RSTS Ope ~rator
- D. Weiss, RM/ALF
- R&SPB
- RSB
- RIV. File
- R. Hall
- R. E. Baer
- L. A. Yandell-
- B. Murray-
R. L. Bangart-
H. N. Berkow, NRR
- w/766
!
.
i
!
1