SEP 17 24 Docket Nos. 50-424/425 NOTE To: Weisfore:.a..cQiraWieader Section A, AEB l
FROM:
Charles A. Willis, Leader Effluent Treatment Systems Section, NET 8
SUBJECT:
V0GTLE ELECTRIC GENERATING PLANT, UNIT NOS. 1 AND 2, FISSION PRODUCT CONTROL SYSTEMS FILTER EFFICIENCIES As prescribed in Standard Review Plan Sections 6.4, 6.5.1, 6.5.3, 15.6.5, Appendicies A and B, 15.7.4, and 15.7.5, we have reviewed the acceptability j
of the design and the efficiencies of the filters to be used in the fission i
product control systems and the control room atmosphere filtration system, as described in the Vogtle Electric Generating Plants, Unit Nos.1 and 2, FSAR.
The filter designs have been determined to be acceptable and in accordance with the guidelines of Regulatory Guide 1.52, with the following excdptions, which are still being evaluated:
1.
No local indication or alarm signals are provided for certain flow, pressure drop, temperature, and status sensors; and 2.
No recorded indication or alarm signals are provided at the control room for certain pressure drop and temperature sensors.
The efficiencies of the filters, pending resolution of the above open l
item, are given in Enclosure A for use in your review under the above sections of the Standard Review Plan.
Questions should be addressed to Charles R. Nichols (x27634), the cognizant reviewer assigned to this facility.
jh $ YY 1 M A Wd.
Charles A. Willis, Leader Effluent Treatment Systems Section.
Meteorology & Effluent Treatment Branch j
As stated I
cc: See next page 4
e a
e
/
M0 'I N IW L
. ~..
..o t
k SEP 171984 T. R. Quay 2,
cc:
D. Muller W. Gamill L. Hulman M. Wohl C. Nichols o
-m.
, ' ~
,' i
,l b
ENCLOSURE A ESF FILTER
- EFFICIENCIES l;
V0GTLE ELECTRIC GENERATING PLANT,, UNIT NOS. 1.AND 2
- }
1.
Particulate removal efficiency HEPA filters, 99
~"
2.
Charcoal filter depth, inches 4
sS (FSAR Table 6.5.1-1)***
l
[
3.
Relative humidity controlled to 70% or less Yes (FSAR Section 6.5.1.2.2).
f 4.
Assigned decontamination factors, %**
a.
Elemental iodine 99 b.
Organic iodide 99 i
I a
"1 4
J i
4 i
- Control Room Emergency Filter System Piping Penetration Filter System, Fuel Handling Building. Post Accident Filter System, and Electrical Penetration Filter System.
i
]
- Based on guidelines of Regulatory Guide 1.52.
- References are in parentheses.