- %g UNITED STATES NUCLEAR REGULATORY COMMISSION g
g y
S WASHINoTON, D. C. 20555
%,...../
APR 181984 MEMORANDUM FOR:
Elinor Adensam, Chief.
~
Licensing Branch No. 4
~
Division of Licensing G. Knighton, Chief Licensing Branch No. 3 Division of Licensing A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing FROM:
Vincent S. Noonan, Chief Equipment Qualification Branch Division of Engineering
SUBJECT:
INFORMATION REQUEST FOR PLANT SITE AUDIT FOR SEISMIC AND DYNAMIC QUALIFICATION REVIEW - HOPE CREEK 1 AND V0GTLE 1 AND BEAVER VALLEY 2 Seismic and Dynamic Qualification and Qualification of Mechanical Equipment reviews consist of two elements.
First is a review of the general program described in the FSAR.
Second is a detailed on-site audit of equipment as installed and the qualification documentation.
The FSAR contains very little information on how the applicant's equipment qualification program is actually being implemented.
Consequently, on-site audit is an important element of our review.
If you have not already requested the information in support of our review and audit from the applicant, we would appreciate it if you would do so.
~
The attached information request is intended to inform the staff of the applicuit's progress in their equipment qualification program. We need this information in,a timely manner to conduct our review a'nd prepare for the on site-audit. ' The applicant r'esponses should be sent to NRC, NRR, Equipment Qualification Branch.
Since we conduct these reviews with the assistance of the national laboratories, also please have the applicant send-one copy of the appropriate part of the response to the following laboratory coordinators:
' Recipient for Information Plant Name Seismic Qualification Pump / Valve Operability Hope. Creek 1 Mr. Jag Singh, INEL-Mr. Clarke Kido, INEL Vogtle 1 Mr. Jag Singh, INEL Mr. 21arke Kido, INEL Beaver Valley 2 Mr. Jag Singh, INEL Mr. Clarke Kido,.INEL
% D)ogC] e m
m
..r.
~
APR 1 8 1984.
The addresses are as follows:
Mr. Jag Singh EG&G Idaho, Inc.
1955 Fremont Ave.
Idaho Falls, Idaho 83415 Mr. Clarke Kido
. Building TSB 7 EG&G, Idaho, Inc.
P.O. Box 1625 Idaho Falls, Idaho 83415 If you have any *,uestions on this~ matter phase call Dr. A. Lee or Mr. J. Jackson of my staff.
h A/22b A6-Vincer.'. S. Noonan, Chief Equi pent Qualification Branch
~
Division of Engineering
Enclosures:
Request for Information Attachment #1 Master Listing of Seismic and Dynamic Qualification and Not~s e
Attachment #2 Seismic and Dynamic Qualification Summary of Equipment Attachment #3 Pump and Valve Operability Assurance Review Attachment #4 Operability Qualification of-Purge and Vent Valves Attachment #5 Guidelines for Demonstration of Operability of Purge and Vent Valves cc: w/o Enclosure R. Vollmer J. Knight E
G. Bagchi M. Miller D. Wagner L. Lazo J. Jackson N. Romney R. Wright
-A.
Lee CONTACT:
A. Lee, X28280 J. Jackson, X27930
- - -