Text

.-

t.-

Attachment C1 f

l ODCM-03.01 Rev 1, Gaseous Effluents su==arv of Chances i

l Section/Page Changes / Reason for change ODCM-03.01 3 of 23 2nd para.

Changed "In addition, prior to containment purge and venting," TO "In addition, prior to containment purging" This change was made because setpoint recalculation is required only for containment purging and to be consistent i

with the rest of the ODCM.

[

ODCM-03.01 l

3 of 231.1.1 Changed " Reactor Building Vent isolation Setpoint" TO

" Reactor Building Vent Alarm Setpoint".

j This change was made because the setpoint exceedance no longer causes the Reactor Building Vent to isolate.

l 1.

1st para.

Changed " Reactor Building Vent Plenum Monitor which Initiates isolation of Reactor Building releases" TO

" Reactor Building Vent Noble Gas Monitor".

i This change was made to differentiate the noble gas 4

monitor from the plenum radiation monitor and because the isolation function has been removed from the noble i

gas monitor system.

ODCM-03.01 1

4 of 23 1.1.1 B Changed "For purge releases, substitute (x/q)v,the highest short term dispersion factor from Table A-12" TO "For purge releases, substitute the value obtained from 4

Chemistry Manual procedure 1.6.07 " Atmospheric 3

Dispersion Determination"".

This change was made to more accurately predict offsite dose from containment purging by using near real time actual dispersion values.

9603050374.960228

~

PDR ADOCK 05000263 R

PDR

i

)

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS

(' ',

Page 1 of 23 i

l l

\\

l ALARA Reviewed By: g,,g,-[

Date: 7/fg /9s Prepared By:

dhh Reviewed By:

h, Date: k n qr OC Final Review Date:M A73 4 ffy f//ak f[////[

Approved By:

-/@g Date:

Resp Supv: S CHEM

' l Assoc Ref: CHEMi

$R: N Freq: Z yrs /

Doc Type: 7030 l ARMS: ODCM l Admin initials: @

DateT/M l()6 j

6

(

djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS Page 2 of 23 This section describes the procedures used by MNGP to:

A. Determine alarm point settings for gaseous effluent monitors; B. Determine that dose rates at the site boundary from noble gases particulates and lodines remain below the limits of Tech Specs; and C. Determine that the total dose from airbome effluents for the year is within the limits of Appendix l of 10 CFR 50(2),

The computations of this section may be done manually, by use of computer programs which implement these algorithms, and or by use of applicable MIDAS algorithms. MIDAS is a set of programs used at Monticello for the accident dose assessment. The applicable MIDAS dose evaluation routines for gaseous effluents may be utilized to perform the dose and dose rate assessments specified in this section.

1.0 MONITOR ALARM SETPOINT DETERMINATION This procedure determines the effluent monitor alarm setpoint that indicates if the dose rate at or beyond the site boundary due to noble gas radionuclides in the gaseous effluent released from the site exceeds 500 mrem / year to the whole body or exceeds 3000 mrem / year to the skin. Accident monitors are set to limit effluent releases to a small fraction of the limits specified in 10 CFR 100. In addition this section calculates the maximum activity permitted in each off-gas storage tank.

Monitor high alarm or isolation setpoints are established in one of the following ways:

A. Monthly calculation of setpoints using the methodology of section 1.1 for noble gas nuclides in releases during the previous month.

B. Prior to each containment purge, recalculation of the setpoint using the methodology of section 1.1 based on the sample taken prior to purging.

1.1 Effluent Monitors Monitor alarm setpoints are determined to assure compliance with Tech Specs.

The setpoints indicate that the dose rate at or beyond the site boundary due to noble gas radionuclides in the gaseous effluent released from the sito exceeds 500 mrem / year to the whole body or exceeds 3000 mrem / year to the skin.

'djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 3 of 23 Monitor alarm setpoints are calculated for the Reactor Building Vent Noble Gas l

monitors and the Stack Noble Gas Monitors once per month. These calculations are based on the noble gas isotopes in releases made during the previous month. The calculations are performed by the DOSGAS computer program in conjunction with Surveillance Test 0342.

In addition, prior to containment purging, the monitor setpoint for the monitor l

release point is recalculated...This calculation is performed by the DWCAL computer program in conjunction with Surveillance Test 0362. The monitor setpoint is determined as follows:

A. If no detectable noble gas activity is found in the purge sample, the values used as the basis for the alarm point setting are from the column, "Drywell venting" in Table 3.1-1, Gaseous Source Terms.

B. If any calculated setpoint is less than the existing monitor setpoint, the setpoint is reduced to the new value.

C. If the calculated setpoint is greater than the existing monitor setpoint, the setpoint may remain at the lower value or be increased to the new value.

D. The setpoint during purging may not be increased above the setpoint determined for continuous releases, however.

Except for containment inerting and deinerting, all containment purging and venting is done via the standby gas treatment system and plant stack.

Containment inerting and deinerting releases are made via the Reactor Building vent. The small amount of containment atmosphere released by the containment sampling system on a continuous basis is not considered a venting operation.

1.1.1 Reactor Building Vent Alarm Setpoint l

The following method applies to gaseous releases via the Reactor Building vent when determining the high-high alarm setpoint for the 1

Reactor Building Vent Noble Gas Monitor. This method is applied to l

both continuous releases and batch releases (containment inerting and deinerting).

A. Determine the " mix" (noble gas radionuclides and composition) of the gaseous effluent.

1'. Determine the gaseous source terms that are representative of b

the " mix" of the gaseous effluent. Gaseous source terms are the total curies of each noble gas released during the previous month djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01

\\

TITLE:

GASEOUS EFFLUENTS Revision 1

~

Page 4 of 23 or a representative analysis of the gaseous effluent. Table 3.1-1 source terms may be used if the Reactor Building releases for the previous month were below the lower limits of detection j

(LLD), or, in the case of inerting and deinerting releases, no detectable activity was found in the grab sample taken prior to purging.

2. Determine S;, the fraction of the total radioactivity in the gaseous effluent comprised by noble gas radionuclide "i", for each individual noble gas radionuclide in the gaseous effluent.

A; S=EA i

i 3.1 -1 i

where A; = The radioactivity of noble gas radionuclide "i" in the gaseous effluent.

B. Determine 0,, the maximum acceptable total release rate of all noble gas radionuclides in the gaseous effluent ( Ci/Sec), based upon the whole body exposure limit (500 mrem /yr).

~ ' '00 5

Q, = (X/Q)yEK;S; 3.1-2 i

where (x/Q), = The highest calculated annual average relative concentration of effluents released via the Reactor Building vent for any area at or beyond the site boundary for all 3

sectors (Sec/m ) from Table A-3. For purge releases, substitute the value obtained from Chemistry Manual Procedure 1.6,07, " Atmospheric Dispersion Determination".

K; The total whole body dose factor due to gamma emissions from noble gas radionuclide "i" (mrem / year / Ci/m ) from Table 3.1-2.

C. Determine Q, based upon the skin exposure limit (3000 mrem /yr).

djj

O MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 5 of 23 3000 Q,

= (pO)J (L + 1.1 M,) S, 3.1 -3 i

I where L + 1.1M; = the total skin dose factor due to r

i emissions from noble gas radionuclide "i" 3

(mrem / year / Cl/m ) from Table 3.1-2, ODCM-13.03.

D. Determine HHSP (the monitor high-high alarm setpoint above background (net Ci/Sec)).

NOTE: Use the lower of the Q, values obtained in Sections 1.1.1.B and 1.1.1.C.

HHSP = 0.50 Q, 3.1-4 0.50 = Fraction of the total radioactivity from the site via the

{

monitored release point to ensure that the site boundary limit is not exceeded due to simultaneous releases from several release points.

1.1.2 Stack Isolation Setpoint The following method applies to gaseous releases via the Stack when determining the high-high alarm setpoint for the Stack Gas Monitor.

d which initiates isolation of Stack releases. The method is applied to both continuous releases and batch releases (containment purges).

Mechanical vacuum pump releases (relatively insignificant) will be controlled using the continuous setpoint.

1 A. Determine thb " mix" (noble gases and composition) of the gaseous effluent.

1. Determine the gaseous source terms that are representative of the " mix" of the gaseous effluent. Gaseous source terms are the total curies of each noble gas released during the previous month or a representative analysis of the gaseous effluent. Table 3.1-1 source terms may be used if the Stack releases for the previous month were below the lower limits of detection (LLD).

djj

O O

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS

( -

Page 6 of 23.

2. Determine S,, the fraction of the total radioactivity in the gaseous effluent comprised by noble gas radionuclide "i", for each individual noble gas radionuclide in the gaseous effluent.

4 r

b=EA i

i 3.1-5 I

where A; = The radioactivity of noble gas radionuclide "i" in the gaseous effluent.

B. Determine Q,, the maximum acceptable total release rate of all noble gas radionuclides in the gaseous effluent ( Ci/Sec), based upon the whole body exposure limit (500 mrem /yr).

500 O = F V,S t

i 3.1 -6 i

NOTE: For short term batch releases (equal to or less than 500 hrs /yr) via drywell purging, substitute v for V,in Equation 3.1-6.

i where V = The constant for long-term releases (greater than 500 hr/yr) for i

noble gas radionuclide "1" accounting for the gamma radiation from the elevated finite plume (mrem / year / Ci/Sec) from Table 3.1-2.

v = The constant for short-term releases (equal to or less than i

500 hr/yr) for noble gas radionuclide "i" accounting for the gamma radiation from the elevated finite plume (mrem /yr/ Cl/Sec) from Table 3.12.

l djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 e-TITLE:

GASEOUS EFFLUENTS Revision 1

Page 7 of 23

{'j -

C. Determine O, based upon the skin exposure limit (3000 mrem /yr).

3000 O, '

= I; (L (X/O), + 1.1B;) S, 3.1 -7 i

NOTE: For short term batch releases (equal to or less than 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year) via drywell purging, use the short-term (x/q), value and substitute b, for B, in Equation 3.1-7.

where L (x/0), + 1.18, The total skin dose constant for long-term releases i

(greater than 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year) due to emissions from noble gas rad.ionuclide "i", Table 3.1-2, mrem / year / Cl/Sec; L;(x/q), 41.1b, The total skin dos'e constant for short-term f,3 releases (less than or equal to 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year)

V due to emissions from noble gas radionuclide "i",

Table 3.1.2, mrem / year / Cl/Sec.

D. Determine HHSP (the monitor high-high alarm setpoint above background ( Cl/Sec).

NOTE: Use the jpwer of the Q, values obtained in sections 1.1.2.B and 1.1.2.c.

HHSP = 0.50 O, 3.1-8 0.50 = Fractl5n of the total radioactivity from the site via the monitored release point to ensure that the site boundary limit is not exceeded due to simultaneous releases from several release points.

1.2 Accident Monitors The gross radioactivity in noble gases removed from the main condenser by means of steam jet air ejectors as measured prior to entering the treatment, adsorption, and delay systems SHALL be limited by an alarm setpoint for the Off-Gas Monitor.

djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS Page 8 of 23 This procedure determines the monitor alarm setpoint that indicates if the potential body accident dose to an individuai at or beyond the site boundary due to noble gas radionuclides in the gaseous effluent released from the site exceeds a small fraction of the limits specified in 10 CFR 100 in the event this effluent, including the radioactivity accumulated in the treatm.ent system, is inadvertently discharged directly to the environment without treatment. This calculation is performed by the OFF-GAS computer program on a routine or an as needed basis. Off-gas flow is automatically terminated when this setpoint is reached.

1.2.1 Maximum Release Rate Determine 0,, the maximum acceptable total release rate in Cl/Sec of all noble gas radionuclides in the gaseous effluent at the Off-gas Monitor after a 5-minute decay, based on the maximum acceptable total release rate of 2.60E5 Cl/See after a 30-minute decay.

A. Determine the off-gas mixture of the gaseous effluent. The off-gas mixture is the fraction of the off gas noble gas radicactivity caused by each recoil diffusion, and equilibrium component. The off-gas mixture is determined, monthly, in conjunction with Monticello Technical Specification 4.8.B.5.c.

B. Determine O, based on the off-gas mixture using Table 3.1-3. This table was prepared using a variation of the NSP EBARR computer code (ODCM-09.01).

1.2.2 Maximum Concentration Determine C,, the maximum acceptable total radioactivity concentration of all noble gas radionuclides in the gaseous effluent ( Cl/CC).

C = 2.12 E-03 i

3.1 -9 where f = The maximum acceptable effluent flowrate at the point of release (CFM);

= 85.5 CFM.

djj

O MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

(}

Page 9 of 23 1.2.3 Monitor Reading Determine C.R., the calculated monitor reading above background attributed to the noble gas radionuclides (mR/hr),

y C,,,t C.R. = E 3.1-10 where E = The detection efficiency of the monitor for noble Oas radionuclides represented in main condenser off-gas ( Ci/CC/mR/hr) from Plant Chemistry Surveillance procedures.

1.2.4 Monitor High High Set-point The monitor high-high alarm setpoint above background (mR/hr) should be set at or below the C.R. value.

()

1.3 Off-ass Storace Tank Maximum Activity The Technical Specifications limit the maximum activity in each storage tank to less than 22,000 curies of noble gas (considered as dose equivalent Xe-133) after 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> of hoidup. To verify that this limit is not exceeded, Table 3.1-3 is used.

The gross radioactivity of noble gases from the main condenser air ejector is determined by isotopic analysis monthly and whenever a significant increase in off gas activity is noted. Analysis of this data is used to determine the primary mode of fission product release from the fuel (recoil, equilibrium, or diffusion) and the gross release rate. This information combined with the condenser air inleakage rate (CFM) and the air ejector monitor release rate is used to confirm that the maximum tank contents limit is not exceeded. This calculation is performed by the OFF-GAS computer program on a routine or as needed basis IAW MNGP Technical Specification 4.8.B.4.a.

Table 3.1-3 is entered with the off-gas mixture (fraction recoil, diffusion, and equilibrium rounded to one decimal place) and the air inleakage rate (in CFM determined from the last tank fill time). The resulting tank activity is multiplied by the current total release rate after a 30 minute decay ( Ci/Sec) and divided by the maximum permitted air ejector release rate of 260,000 Ci/Sec. Linear interpolation of air inleakage is used.

l djj l

l MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 10 of 23 1

As noted earlier, Table 3.1-3 is derived from the EBARR computer program described in ODCM-09.01. It is extremely unlikely that the maximum tank

)

activity limit will be exceeded.

2.0 GASEOUS EFFLUENT DOSE RATE - COMPLIANCE WITH TECH SPECS (TS)

Dose rates resulting from the release of noble gases, and from radiciodines and particulates must be calculated to show compliance with Tech Specs (TS). The dose rate limits of Tech Spec (TS) are conservatively applied on an instantaneous basis at the hypothetical worst case location.

2.1 Noble Gases The dose rate in unrestricted areas resulting from noble gas effluents is limited by Tech Spec (TS) to 500 mrem /yr to the total body and 3000 mrem /yr to the skin. The setpoint determinations discussed in the previous section are based W. This on the dose rate calculation method presented in NUREG-0133 represents a backward solution to the limiting dose rate equations in NUREG 0133. Setting alarm trip setpoints in this manner will insure that the i

limits of Tech Spec (TS). are met for noble gas releases. Therefore, no routine dose rate calculations for noble gases will be needed to show compliance with this part. Routine calculations are made for dose rates from noble gas releasm to show compliance with 10 CFR 50, Appendix l by performing the DOSGAS l

computer program; -

2.2 Radiolodine and Radioactive Particulates and Other Radionuclides The dose rate in unrestricted areas resulting from the release of radiciodines l

and particulates with half lives greater than 8 days is limited by Tech Spec (TS) to 1500 mRemiyr to any organ. The calculation of dose rate from radiciodines and particulates is performed for drywell purges prior to the release and weekly for all releases. This calculation is performed by the DWCAL computer program for drywell purges and 1/ week by the IPART computer program for all releases, which is run in conjunction with Surveillance Test 0356. The calculations are based on the results of analyses obtained pursuant to MNGP Technical Specifications 4.8.B.1.b. To show compliance with Tech Spec (TS), Equation 3.2-1 or the MIDAS equations shown in ODCM-11.01 will be evaluated for 1-131,1-133, tritium, and radioactive particulates with half lives greater than eight days.

djj

e t

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS Q

Page 11 of 23

[(x/Q ) Q + (x/O,) 0,] < 1500 mrem /yr 3.2-1 epi y

3y 3

where

= child critical organ dose parameter for radionuclide i for the inhalation Pi 3

pathway, mrem /yr per Cl/m ;

(x/Q), = annual average relative concentration for long-term release from the 3

Reactor Building vent at the criticallocation, Sec/m (ODCM-13.06 Table A-3);

(x/Q), = annual average relative concentration for long-term releases from the 3

off-gas stack at the criticallocation, Sec/m (Appendix A, Table A-6);

O,y

= the release rate of radionuclide i from the Reactor Building vent for the week of interest, Ci/Sec; O

O,,

= the reieese rete of redionuciide i frem the off-oes steck for the week of interest, Ci/Sec.

The x/O values presented in Tables A-3 and A-6 have been calculated using the USNRC computer code "XOODOQ."W Dose rate calculations using Equation 3.2-1 are made once per week. The source terms Qy and Q, are i

determined from the results of analysis of weekly stack and Reactor Building particulate filters and charcoal cartridges. These source terms include all l

gaseous releases from MNGP. They are recorded and reported as the total dose for compliance with 10 CFR 20.

Radiciodines and particu'lates may be released from both the off-gas stack and I

the Reactor Building vent. As specified in NUREG-0133, the critical receptor location is identified based on the Reactor Building vent x/Q.

A component of the total stack or vent source term may be due to short term releases occurring as a result of containment drywell purging. Dose rate calculations are made on this component separately to further assure compliance with Tech Spec (TS) prior to release. The calculated dose rate is used only to determine whether or not the drywell can be purged. All dose rates from drywell purges will be accounted for and reported through the weekly calculations discussed above. Release rates are determined from the results of

(

analyses of samples from the drywell.

djj l

l i

\\

~

l MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 12 of 23

'~

The term Q;, for the calculation of drywell purge dose rate is determined by multiplying the concentration of each nuclide in the drywell by the rate of release. Credit will be taken for the expected reduction in radionuclide concentration due to use of the standby gas treatment system. Equation 3.2-2 is used to calculate purge dose rates. Only one source term is used depending

)

on the release point (stack or Reactor Building vent). Short term values of x/q from the Table A-9 or Table A-12 is used in the purge dose rate calculation.

the limiting dose rate limit for each purge is determined using:

BL

= 1500 - (D,y + D,, - Ddw) 3.2-2 l

where BL

= limiting dose rate for the batch, mrem /yr; D,y = previous week's dose rate from Reactor Building continuous and batch releases, mrem /yr; D,,

= previous week's dose rate from off-gas stack continuous and batch releases, mrem /yr; D

= previous week's total dose rate from drywell purge releases, mrem /yr, dw

~

for the purgd release point.

Although mechanical vacuum pump releases are batch mode, they cannot be sampled prior to release. For this reason, no prerelease dose rate calculations can be made from this source. Experience has shown mechanical vacuum pump release to be well within Tech Spec (TS) limits.

i 2.3 Critical Receptor Identification 4

As stated in 5.2.1 of NUREG-0133, when the critical receptor is different for stack and vent releases, the controlling location for vent releases should be used. For this reason, the Reactor Building vent dispersion parameters are used to identify the critical receptor. The real time atmospheric dispersion factor (x/Q) is calculated by performing the MIDAS XP computer program LAW

)

MNGP Chemistry Procedure 1.6.07. As discussed previously, weekly and batch dose rate calculations are performed for the critical boundary location. The critical boundary location is based on reactor vent long term x/Q (Table A-3) is 0.43 miles in the SSE sector.

1 i

djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 13 of 23 s

3.0 GASEOUS EFFLUENTS - COMPLIANCE WITH 10 CFR 50 Doses resulting from the release of noble gases, and radiolodines and particulates must be calculated to show compliance with Appendix l of 10 CFR 50. The calculations are performed monthly for all gaseous effluents. Calculations of the doses received due to the release of noble gases is performed by the D'OSGAS computer program. Similarly the dose received due to the release of radiolodines and particulates is calculated by the DOSPIT computer program. These two programs are performed monthly or as required in conjunction with Surveillance Test 0342.

1 This section describes the methods and equations used at MNGP to perform the dose evaluation using manual methods based on historical meteorological dispersion parameters and using the MIDAS computer methods with contemporaneous meteorological dispersion parameters.

3.1 Noble Gases The air dose in unrestricted areas at MNGP is limited to:

~

O A. for env ceiender neerter:

D s 5 mrad due to gamma radiation; and 7

Dp 5 10 mrad due to beta radiation; and B. for any calendar year:

D 5 10 mrad due to gamma radiation; and 7

Dp 5 20 mrad due to beta radiation.

Air doses may be calculated using historical meteorologicai data using the highest normalized concentration statistics as the best estimator of the atmospheric dispersion, or the doses may be computed using the contemporary meteorological data during the period of the release. Either method may be used and both are described below.*

3.1.1 Air Dose Based on Historical Meteorology The limiting air dose, D, based on historical meteorology is based on the critical receptor in the unrestricted area. For air doses the critical receptor is described by the off-site location with the highest long term i

annual average relative concentration (x/Q) at or beyond the restricted b

djj

{

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 14 of 23 area boundary. For short-term vent releases (less than 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year), the location with the highest short-term average relative concentration (x/q) is chosen. The critical receptor is described in section 3.5.

For gamma radiation, the air dose is given by:

D = 3.17 X 10-8 I(M [(x/0) yO,y+ (x/q) yq,y] + B,0, + b,qi,)

3.3-1 7

3 i

The historical meteorological data base is the basis for the method described in the original MNGP ODCM. With the addition of the MIDAS system to the MNGP, it is now possible to estimate doses based on contemporaneous data?

For beta radiation, the air dose is:

Dp = 3.17 X 10-8 E N, [(x/0)y0;y+ (yfq),q,y + (x/0),0;, + (X 4) 4j,1

/

~l 3.3-2 where:

M,

= The air dose factor due to gamma emission for each identified 3

noble gas radionuclide i, mrad /yr per Ci/m ; (Table 3.3-1)

N,

= the air dose factor due to beta emissions for each identified 3

noble gas radionuclide I, mrad /yr per Cl/m ; (Table 3.3-1)

(x/0)y = the annual average relative concentration for areas at or beyond the E,ite boundary for long-term Reactor Building vent 3

releases (greater than 500 hr/yr), Sec/m, (ODCM-13.06, Table A-3);

(x/q), = the relative concentration for areas at or beyond the site boundary for short-term Reactor Building vent releases (equal to or less than 500 hr/yr), Sec/m, (ODCM-13.06, Table A-12);

(x/Q), = the annual average relative concentration for areas at or beyond the site boundary for long-term off-gas stack releases 3

(greater than 500 hr/yr), Sec/m, (ODCM-13.06, Table A-6);

i djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 4

TITLE:

GASEOUS EFFLUENTS Revision 1

Page 15 of 23

()

(y/q), = the relative concentration for areas at or beyond the site boundary for short-term off-gas stack releases (equal to or 3

less than 500 hr/yr), Sec/m (ODCM-13.06, Table A-9);

qi,

= the average release of the noble gas radionuclide i in gaseous effluents for short-term off-gas stack releases (equal to or less than 500 hr/yr), Ci; q;y

= the average total release of the noble gas radionuclide i in gaseous effluents for short-term Reactor Building vent releases (equal to or less than 500 hr/yr), Cl; O,

= the total release of noble gas radionuclide i in gaseous 3

releases for long-term off-gas stack releases (greater than 500 hr/yr), Cl; Q,y

= the total release of noble gas radionuclide iin gaseous effluents for long-term Reactor Building vent releases (greater

'(

than 500 hr/yr), pCi; B,

= the constant for long-term releases (greater than 500 hr/yr) for each identified noble gas radionuclide i accounting for the gamma radiation from the elevated finite plume, mrad /yr per Cl/Sec; b,

= the constant for short-term releases (less than or equal to 500 hr/yr) for each identified noble gas radionuclide i accounting for the gamma radiation from the elevated finite plume, mradlyr per Ci/Sec; 3,17 X 10-8

= the inverse of the number of second' 'n a year.

i Noble gases are continuously released from t..e Reactor Building vent and the plant stack. These long-term releases rates are determined from the continuous noble ga.s monitor readings and periodic radionuclide analyses. There are infrequent containment purges from either release point. To separate the short-term release from the long term release (the continuous monitor records both), the drywell source term should be subtracted from the total source term whenever a purge i

djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS Page 16 cf 23 i

release occurs. Periodic radionuclide analysis of main condenser off-gas and radionuclide analysis of each purge prior to release are usea in conjunction with the total activity measured by the monitor to quantify individual noble gas nuclides released.

Long-term and short-term x/Q's are given in ODCM-06.01 for both the Reactor Building vent and the plant stack. Short-term x/q's were calculated using the USNRC computer code "XOQDOQ" assuming 144 hours0.00167 days <br />0.04 hours <br />2.380952e-4 weeks <br />5.4792e-5 months <br /> per year drywell purge. Values of M and N were calculated using the methodology presented in NUREG 0133 and are given in Table 3.3-1. Table 3.3-2 presents values of B, and b, calculated using the USNRC computer code "RABFIN." This code was also used to calculate values of V presented in section 1.0. Values of v, were i

i calculated by multiplying V by the ratio of b;to B;. The v,,18, and b, i

3 values of Table 3.3 2 are the maximum values for the site boundaries location. This location,0.51 mi SSE, is different than the critical site boundary location based upon the Reactor Building vent x/Q.

3.1.2 Air Dose Based on Contemporaneous Meteorology Using MIDAS The air dose based on contemporaneous meteorology is performed in MIDAS (6) using the XDAIR routine. XDAIR uses the methods described under XDCALC with some parameters defined to provide the air dose computations. The XDCALC function is used to calculate atmospheric dispersion and doses according to the models prescribed in Regulatory Guides 1.109(7)and 1.111.(8) The MIDAS equations are given in ODCM-11.01.

j Hourly values of x/O are calculated and are used to compute beta and gamma air doses. These doses are cumulated for the duration of the release. Calculations use hourly site meteorological data averages, centerline, depletion, and deposition calculations are performed.

For gamma or beta radiations the air doses are given by:

17 D, air = 3.6 X 10 y/O I DF Q,

or 4

y I I i=3 17 p

D, air = 3.6 X 10 x/O I DF Q,

3.3-3 4

I I i=3 djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision.

1 Page 17 of 23 where:

D, air =

gamma air dose, rad / hour; y

D, air =

beta air dose, rad / hour; WO=

appropriate WO for ground, mixed, or elevated release, 8

Sec/m (see ODCM-11.01);

i (3 to 17)=

nuclide indices in MIDAS for noble gases:

DF7=

the air dose factor due to gamma radiation for each i

identified 8

noble gas radionuclide. In (mrad m )/(Cl Sec) (see Table 3.3-2);

DFE=

the air dose factor due to beta radiation for each I

identified 3

noble gas radionuclide. in (mrad m )/(Ci Sec)(see h

Table 3.3-2);

Qi=

release rate in uCi/Sec for each nuclide; and 3.6 X 10'S=

rad Cl' 3600 Sec mrad Ci hour The MNGP uses both an elevated stack and building vents for releases. MIDAS uses the appropriate 40 for the computation depending on the source of the release. The computation of WO in MIDAS for all cases is given in ODCM-11.01 under the section i

describing the Program XDCALC.

3.2 Radiolodine. Particulates, and Other Radionuclides The dose, D,j, to an individual from radiciodines, radioactive materials in particulate form and radionuclides other than noble gases with half lives greater than eight days in gaseous effluents released to unrestricted areas SHALL be limited to:

i D,j s 7.5 mrem for any calendar quarter D 5 15 mrem for any calendar year 4

k..

djj

4 MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS Page 18 of 23 These limits apply to the receptor location where the combination of existing pathways and age groups indicates the maximum exposure. For this reason the MIDAS dose assessment algorithms should be used if available. Alternatively the infant dose at the historical highest y/O may be used. Both methods are described below.

r 3.2.1 Dose from Radiolodines and Particulates Based on Historical Meteorology The worst case dose to an individual from I-131, tritium and radioactive particulates with half-lives greater than eight days in gaseous effluents released to unrestricted areas is determined by the following expressions:

D,j = 3.1 7 X 1 0'8IIRig [W O,y+w q;y + W,0,,+w,q;,]

3.3-4 y

y pl where:

(

O,

= release of radionuclide i for long-term off-gas stack releases i

(greater than 500 hr/yr), Ci; Q,y

= release of radionuclide i for long-term Reactor Building vent releases (greater than 500 hr/yr), Ci; qi,

= release of radionuclide i for short-term off-gas stack purge releases (equal to or less than 500 hr/yr); Ci; q,y

= release of radionuclide i for short-term Reactor Building vent purge releases (equal to or less than 500 hr/yr); Ci; i

W,

= the dispersion parameter for estimating the dose to an individual at the controlling location for long-term off-gas stack releases (greater than 500 hr/yr), Sec/m or m 2; 3

W

= the dispersion parameter for estimating the dose to an y

individual at the controlling location for long-term Reactor Building vent releases (greater than 500 hr/yr), Sec/m or m 2; 3

w, -

= the dispersion parameter for estimating the dose to an individual at the controlling location for short term off-gas stack releases (equal to or less than 500 hr/yr), Sec/m or m 2; i

djj i

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 Revision 1

TITLE:

GASEOUS EFFLUENTS Page 19 of 23 f;

w

= the dispersion parameter for estimating the dose to an y

individual at the controlling location for short term Reactor 8

Building vent releases (equal to or less than 500 hr/yr), Sec/m or m 2 3.17 X 10'8

= the inverse of the number of seconds in a year.

R

= the dose factor for each identified radionuclide i, pathway p, g

2 age group a, and organ J, m mrem /yr per Cl/Sec or mrem /yr per pCl/m.

The above equation is applied to each combination of age group and organ. Values of R;g have been calculated using the methodology given in NUREG-0133 and are given in Tables 3.3-3 through 3.3-21.

The equation is applied to a controlling location which will be one of the following:

A. residence,

-l B. vegetable garden, C. milk animal.

The selection of the actual receptor is discussed in section 3.3. The source terms and dispersion parameters in Equation 3.3-3 are obtained in the same manner as in section 2.0. The W values are in terms of x/O (Sec/m ) for the inhalation pathways and for tritium and in terms of 3

D/O (m' ) for all other pathways.

values. This Appendix E contains the methodology for calculating Ry method will be used to compute dose factors for nuclides not tabulated in Tables 3.3-3 through 3.3-21 if they are encountered.

3.2.2 Dose Based on Contemporaneous Meteorology Using MIDAS The dose to individuals from I-131, tritium and radioactive particulates may be calculated using the MIDAS system algorithms. In MIDAS the Program GASPRO computes the accumulation of dose to individual receptors or to the surrounding population based on hourly meteorological data collected by MIDAS and release data from other

('

computer programs utilizing the algorithms in this manual or other manual inputs.

djj

i MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

' ~

Page 20 of 23

. Dose calculations are performed for each important nuclide for each pathway, organ, age group, distance and direction.

Radionuclide and pathway are used in GASPRO to determine the appropriate dispersion type to be used. Three types of atmospheric dispersion factors are used, y/O, y/O(depleted), and D/O, depending on pathways and nuclide.

Hourly meteorological data is used so atmospheric conditions are contemporaneous with release.

The GASPRO calculations are based on the environmental pathways-to-man models prescribed by the NRC in Regulatory Guide 1.109. Dose factors for the individual doses (and for population doses) are based on results run-off line using the Pickard, Lowe, and Garrick (PLG) version of GASPAR.' These data are tabled and used by the MIDAS routine in a look-up mode. These tables are given in MIDAS Tables 2.2.6.3-1 and 2.2.6.3-2 for individual Dose Factors and Population Dose Factors, respectively. These tables are included in this manual in ODCM 11.01.

GASPRO calculates doses for the following pathways, organs and age groups.

MIDAS Index Pathway 1

Plume 2

Ground Shine 3

Vegetable 4

Meat 5

Cow Milk 6

Goat Milk 7

inhalation MIDAS

!n_d_ex Oraan Total Body 2

GI Tract 3

Bone 4

Liver 5

Kidney 6

Thyroid 7

Lung 8

Skin j

dj]

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision -

1 O

Page 21 of 23 MIDAS Index Ace Group 1

Adult 2

Teen.

i 3

Child 4

Infant Five types of receptors as indicated below can be located at up to 10 distances in each of the direction sectors.

MIDAS Index Receotors 1

Residents 2

Vegetable Gardens 3

Meat Animals 4

Cows 5

Goats The resident location is used to calculate plume shine dose, ground shine from deposited material, and inhalation dose. Normal dispersion, depleted dispersion and ingestion pathways are used as appropriate.

Average X/O, depleted x/O and deposition are computed using the current hour meteorological data.

Doses are computed and accumulated hourly by direction, distance organ or receptor, age group, and pathway. A finite plume gamma dose model is used to calculate the dose from noble gases. Submersion skin dose is calculated separately from whole body dose and the total skin dose from noble gases is computed by adding the finite gamma plume dose to the submersion skin dose using the appropriate Reg. Guide 1.109 dose factors. The equations used in MIDAS for the dose computations are given in ODCM-11.01 3.3 Cumulation of Doses Doses calculated monthly are summed for comparison with quarterly and annual limits. The monthly results are added to the doses cumulated from the other months in the quarter of interest and in the year of interest and compared to the limits given in section 3.1 and 3.2. This summation is performed by the DOSGAS and the DOSPIT computer program for doses from exposures due to noble gas, and radiolodine and particulates respectively. If these limits are exceeded, a Special Report will be submitted to the USNRC in accordance with

("

the MNGP Technical Specifications. If twice the limits are exceeded, a Special Report showing compliance with 40 CFR 190 W will be submitted.

djj

+

MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 22 of 23' 3.4 Projection of Doses Projection of doses is not necessary. The Technical Specifications require the off-gas holdup system to be operated at all times.

/

3.5 Critical Receptor identification The critical receptors for compliance with 10 CFR 50, Appendix I will be identified. For the noble gas specification the critical location is based on the extemal dose pathway only. This location is the off-site location with the highest long-term Reactor Building vent y/O and is selected using the x/O values given in ODCM-13.06, Table A-4. The critical receptor location is used for showing compliance with 10 CFR 20 and remains the same unless meteorological data is re-evaluated or the site boundary changes.

The critical location for the radiciodine and particulate pathway is selected once per year. This selection follows the annualland use census performed within 5 miles of the MNGP. Each of the following locations is evaluated as a potential critical receptor before implementing the effluent technical specifications:

A. Residences in each sector.

B. Vegetable garden producing leafy green vegetables.

C. Allidentified milk animallocations.

The critical receptor is selected based on this evaluation.

Following the annual survey, doses are calculated using Equation 3.3-4 for all newly identified receptors and those receptors whose characteristics have changed significantly. The calculation includes appropriate information shown to exist at each location: The dispersion parameters given in this manual should be employed. The total releases reported for the previous calendar year should be used as the source term.

djj

.~

O MONTICELLO NUCLEAR GENERATING PLANT ODCM-03.01 TITLE:

GASEOUS EFFLUENTS Revision 1

Page 23 of 23 REFERENCES

1. Monticello Nuclear Generating Plant Technical Specifications, TS B.2.4-Radioactive Effluents, Specification 2.4.3F Rev. 25.
2. USNRC, Title 10, Code of Federal Regulation, Part 50, " Domestic Licensing of Production and Utilization Facilities", Appendix 1, " Numerical Guides for Design Objectives and Limiting Conditions for Operation to Meet the Criterion

'As Low as is Reasonably Achievable' for Radioactive Material in Light-Water-Cooled Nuclear Power Reactor Effluents"

3. NSP - Monticello Nuclear Generating Plant, Appendix i Analysis -

Supplement No.1 - Docket No. 50-263, Table 2.1-3.

4. Boegli, J.S., et. al. Eds, " Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants, NUREG-0133,1978, NTIS, Springfield Va.
5. Sangendorf, J.F. and J. T. Goll, "XOODOQ - Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations",

NUREG-0324,1977, USNRC, Washington, D.C.

6. Pickard, Lowe and Garrick, Inc., (Proprietary), " MIDAS Users Manual",

Section 2.2.6, " Environmental Pathway and Dose Calculations for Liquid and Gaseous Effluents" j

7. USNRC, Regulatory Guide 1.109, " Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of L-valuating Compliance with 10 CFR 50, Appendix I", Rev.1 Oct.1977, USNRC, Washington D.C.
8. USNRC, Regulatory Guide 1.111, " Methods for Estimating Atmospheric j

Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors", July 1977. USNRC, Washington, D.C.

9. EPA, Title 40, Code of Federal Regulations, Part 190 " Environmental Radiation Protection Standards for Nuclear Power Operations" t

e djj

- - -.... ~.

6 4

3:

l Attachment C2 l

i ODCM-12.05 Rev 1, ODCM-05.01 Figures 1

l

. Summary of Chattaes Section/Page Changes / Reason for change I

ODCM-12.05 2 of 4 Updated the map of REMP sampling locations This change was made because the locations had 3

changed.

1 ODCM-12.05 4

3 of 4 Updated the map of 4-5 mile ring control and special interest TLD locations.

This change was made because a TLD (05S) location had changed.-

f 1

i 4

e i

-j-i 1

l l

t' one e

m

.w

F i.

is MONTICELLO NUCLEAR GENERATING PLANT ODCM-12.05 TITLE:

ODCM-05.01 FIGURES Revision 1

Page 1 of 4 l

s-

? d:

.34 r

~.....

' ? s'.

1 i

e.

..n l

j

/.l-

.;,~

p L

l.):/_'. ':.

~

kJ O,y g.

F i

{,' '

i 1

i.

- 1,e

'L-3, %. r e

s r

{,,

s.

ALARA Reviewed By:ffg g

Date:,3 /j3 /9,r I

r 1-~

Prepared By: (f( gg, Reviewed By: [k Date:

't - 28 M OC Final Review Date:

/Wrf;

/7ff, f[4/(

4 f/n[f[

Approved By:

,/

Date:

i p

Resp Supv: S CHEM l Assoc Ref: CHEMi

[SR;, N Freq: 7l yrs /,

Doc Type: 7030 l ARMS: ODCM l Admin initials:l @

Date:( lN4 / (d 6

. djj NQ

. = _ -

MONTICELLO NUCLEAR GENERATING PLANT ODCM-12.05 TITLE:

ODCM-05.01 FIGURES Revision 1

l Page 2 of 4

^

i i..

y.

.n

~

g a m en l-v..

mym

.,4

%e 1

T,yx f

(

l i

A N

J !7'

/

[

~

b g

M AW

~ ; %.

9 s

43.

i

/,

s a

s 2

m l

/ l

' %l

.)

(Kj 4

:y y A'

g 9

s a

A o 00 c

x

/

v

/

gf.

t

-t a

w

~

lI s

()

M

~

_n I'

/Q3 {,

~#'

e b

g

(' h=.W s.

/

i

/y-l x

~

/ *~2% Tl? g 'L" dii

MONTICELLO NUCLEAR GENERATING PLANT ODCM.12.05 Revision 1

TITLE:

ODCM-05.01 FIGURES

, O, Page 3 of 4 N

3

. / e 'w7-I vo g,l.

l

'/

g' n

.. sM;

! n-4 j!

gg$l8

/\\ [id,

' iM)

~~

. lllgl ~~E i

3 m

D}'

~i-c c

? m,,. n

.ng

/

,p h

/\\

K 7

.C 7, *--

\\/

i 5

0, N

a y

=

i

/

/

's /e I ( 't

\\

h. [~

.O N,L l',* :

i f

93

/

q 2

0 4

r j3 i

e

-../.

c'3!\\f y's l,;-I >

f8 /$

N

')

~

i 00

=

o

#\\i

-i l'

M

//

@2 t_4

/

i.--

.,N-i 7

2* -

li l

\\

(

/

J._

co dij

MONTICELLO NUCLEAR GENERATING PLANT ODCM-12.05 TITLE:

ODCM-05.01 FIGURES.

Revision 1

Page 4 of 4-0 I

\\

8 3

2 5

s e

/ h!

f E

j

_f

.a; b!

R E

/

"E "x

/;(G N

j

~

J i.

9 A.

[85i

~

g

.[

8 g a

.6 bhh

\\

n x (N

,gfc (A

W

/

s CD Oo

,e O

as

/

=

,1

/

+

=

~

}

s g

\\

/

g' yy 5

1 09 9 O u

e 2

w o

b O

se m

s

~

~

Oas !

Eo 88-Ed E$ $

5 2

djj i

- ~ -

4 Attachment C3 ODCM-13.05 Rev 1, ODCM-05.01 Tables S ti=== ry of Chances Section/Page Changes / Reason for change 1

s ODCM-13.05 2 of 5,3 of 5, l

4 of 5 Changed REMP sampling location descriptions. Changed collection site names and locations.

l The REMP sampling location descriptions were changed in response to an NSP " Nuclear Quality Dept. " internal audit report. The sample collection site names and l

locations were changed to reflect land uses census results.

i i

i f

?

l t

r I

i i

l

c.

e 0

MONTICELLO NUCLEAR GENERATING PLANT ODCM-13.05 TITLE:

ODCM-05.01 TABLES ReviSlon 1

Page 1 of 5 l

i i

l i

1 i

4 f

o i

l ALARA Reviewed By: gj g

Date: 7 /f 3,/93 Prepared By:

y M Reviewed By: g}

Date: 3 7g g i

OC Final Review DateY

/ttf6 # j9ft f/hoff f///k Approved By: [

gp_

Date:

Resp Supv: S CHEM l Assoc Ref: CHEMi ASIV N Freq: 2) yrs l n Doc Type: 7030 l ARMS: ODCM l Admin initials ( Ih Date: 7M /V) 6

)6

MONTICELL5 NUCLEAR GENERATING PLANT ODCM-13.05 TITLE:

ODCM-05.01 TABLES Revision 1

Page 2 of 5 Title 5.1-1 Monticello Nuclear Generating Plant Radiation Environmental l

Monitoring Program Sampling Locations a

Location Distance Compass Type of Sample Code Collection Site Miles Heading Sector River water M-8 Upstream of plant wAn 1000 ft upstream of plant intake l

~

w/in 1000 ft downstream of plant River water M-9 Downstream of plant discharge Drinking water M-14 City of Minneapolis 36.

128 SE Well water M-10 Goenner Farm 12.5 321 NW Well water M-11 City of Monticello 3.2 128 SE Well water M-12 Plant Well No.1 0.2 267 W

Well water M-13 Ernst Residence 0.6 202 SSW Sediment-River M-8 Upstream of plant w/in 1000 ft upstream of plant intake w/in 1000 ft downstream of plant Sediment-River M-9 Downstream of plant discharge Sediment-Shoreline M-15 Montissippi Park 1.6 117 ESE Upstream of plant w/in 1000 ft upstream of plant intake ac o nver.

tebrates M-8*

w/in 1000 ft downstream of plant M-9 Downstream of plant discharge Fish M-8 Upstream of plant w/in 1000 ft upstream of plant intake I

w/in 1000 ft downstream of plant Fish M-9 Downstream of plant discharge Milk M-10 Goenner Farm 12.5 321 NW l

Milk

, M-24 Weinand Farm 4.8 180 S

Milk M-28 Hoglund Farm 3.7 300 WNW l

djj

1 ;,

MONTICELLO NUCLEAR GENERATING PLANT ODCM-13.05 TITLE:

ODCM-05.01 TABLES Revision 1

Page 3 of 5 p

Title 5.1-1 Monticello Nuclear Generating Plant Radiation Environmental Monitoring Program Sampling Locations (continued]

Location Distance Compass Type of Sample Code Collection Site Miles Heading Sector Cultivated crops (leafy green vegetables)

M-10

a. Available Producer

>10.0 a.

a.

M-27 Highest D/O Garden 0.7 200 SSW (corn)*

(potatoes)*

Particulates and Radiciodine (air)

M-1" Air Station M-1 11.1 306 NW (air)

M2 Air Station M-2 0.8 140 SE (air)

M-3 Air Station M-3 0.6 104 ESE (air) ~

M-4 Air Station M-4 0.9 150 SSE (air)

M - Air Station M-5 2.7 136 SE Direct Radiation - (general area of the site boundary)

(TLD)

M01A North Boundary Rd.

0.7 353 N

i (TLD)

M02A North Boundary Rd.

0.8 23 NNE (TLD)

M03A North Boundary Rd.

0.1 43 NE (TLD)

M04A Biology Station Rd.

0.7 92 E

(TLD)

MO5A Biology Station Rd.

0.6 112 ESE (TLD)

M06A Biology Station Rd.

0.6 133 SE (TLD)

M07A County Road 75 0.5 158 SSE (TLD)

M08A County Road 75 0.5 183 S

(TLD)

M09A County Road 75 0.4 203 SSW (TLD)

M10A County Road 75 0.3 225 SW (TLD)

M11A County Road 75 0.4 250 WSW Collected only if plant discharges radioactive effluent into the river, then only from river irrigated fields. (See Sec. 5.1) djj

MONTICELLO NUCLEAR GENERATING PLANT ODCM-13.05 TITLE:

ODCM-05.01 TABLES Revision 1

Page 4 of ( '

Title 5.1-1 Monticello Nuclear Generating Plant Radiation Enviro.imental Monitoring Program Sampling Locations (continued]

Location Distance Compass Type of Sample Code Collection Site Miles Heading Sector (TLD)

M12A County Road 75 0.7 273 W

(TLD)

M13A North Boundary Rd.

1.1 317 NW (TLD)

M14A North Boudnary Rd.

0.8 338 NNW Direct Radiation - (about 4 to 5 miles distant from the plant)

(TLD)

M01B Sherco No.1 Air Sta.

4.6 2

N (TLD)

M02B County Road 11 4.4 17 NNE (TLD)

M03B County Rd. 73 & 81 4.5 49 NE (TLD)

M04B Sherco No. 6 Air Sta.

4.2 67 ENE (TLD)

M05B City of Big Lake 4.4 87 E

(TLD)

M06B County Rd 14 & 196 4.3 116 ESE St (TLD)

M078 Monte Industrial Dr.

4.4 135 SE (TLD)

MOBB Dale Larson Res.

4.6 162 SSE (TLD)

M09B - Norbert Weinand 4.7 180 S

Farm (TLD)

M10B John Reisewitz Farm 4.4 206 SSW (TLD)

M11B Clifford Vanlith Farm 4.2 225 SW (TLD)

M12B Lake Maria St. Park 4.4 253 WSW (TLD)

M13B Bridgewater Sta.

4.1 271 W

(TLD)

M14B Richard Anderson 4.5 288 WNW Res.

(TLD)

M15B Gary Williamson 4.5 308 NW Res.

(TLD)

M16B Sand Plain Research 4.3 338 NNW Farm Direct Radiation - (special interest locations)

(TLD)

M01S Osowski Farm Market 0.7 130 SW l

(TLD)

M02S Edgar Klucas Res.

0.7 142 SE (TLD)

M03S Big Oaks Park 1.3 89 E

(TLD)

-M04S Pinewood School 2.3 132 SE (TLD)

M05S Rivercrest Christian 2.6 112 ESE Academy djj

i MONTICELLO NUCLEAR GENERATING PLANT ODCM-13.05 TITLE:

ODCM-05.01 TABLES Revision 1

Page 5 of 5

{

Title 5.1-1 Monticello Nuclear Generating Plant Radiation Environmental Monitoring Program Sampling Locations [ continued]

Location Distance Compass Type of Sample Code Collection Site Miles Heading Sector (TLD)

M06S Monte Public Works 2.7 136 SE (TLD)

M01C Kirchenbauer Farm 11.5 323 NW Notes on Table 5.1-1:

"c" denotes control locations. All other locations are indicator locations.

a. Control" leafy green" vegetable will be taken in locations as available outside 10 mi.EPZ.

The letters after TLD code numbers have the following meanings:

A Locations in the general area of the site boundary;

()

B Locations about 4 to 5 miles distant from the plant; S Specialinterest locations.

I m