ML20127P232

From kanterella
Jump to navigation Jump to search
Revised Software Requirement Specification (SRS) ERDS-SRS-2-B, Emergency Response Data Sys (ERDS) Data Point Library
ML20127P232
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 01/19/1993
From: Sofge J, Van Dell R
NORTHERN STATES POWER CO.
To:
Shared Package
ML20127P200 List:
References
ERDS-SRS-2-B, NUDOCS 9302010218
Download: ML20127P232 (60)


Text

{{#Wiki_filter:- _ _ - _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ - _ _ - _ - _ _ _ _ _ _ c CVI-4.3 SOFTVARE REQlf1REMENT CFNs ERDS-SRS-2-B 3/25/91 SPECIFICATION (SRS) SR _ 0Atyng0A TITLE EMERGENCY RESPONSE DATA SYSTEH Prepared by: RussVankek (ERDS) DATA POINT LIBRARY Date Issued: January 19, 1993 INDEX NRC ERDS Parameter Pages Revision NI POWER RANGE 2 1 NI INTER RANGE 3 1 NI SOURC RNG-4 1 REAC VES LEV 5 1 RCS PRESSURE 6 2 MAIN FD FLOV 7 1 HPCI FLOV 9 2 RCIC FLOV 10 1 LPCI FLOV 11 1 CR SPRAY FL 15 1 DV FD SMP LV 17 1 EFF GAS RAD 19 1 EFF LIO RAD 23 1 COND A/E RAD 29 1 DV RAD 31 1 HN STEAM RAD 33 1 DV PRESS 34 1 DV TEMP 35 1 SP TEMP 36 1 SP LEVEL 37 1 H2 CONC 38 1 CST LEVEL 42 1 VIND SPEED 44 1 VIND DIR 48 i STAB CLASS 52 1 Contacts 56 1-Selection of Data Feeders 57 1 Data Feeder Information 58 1 1 Revieved By: J.T. Sofge b Date: 1/19/93 Approved Bys_ R.E. Van ate: 1/19/93 9302010218 930125 PDR ADOCK OS000263 F PDR

4 NSF NONTICELIA) NUCLEAR GENERAT&NG PLANT ERDS-5RS-2-B-ERDS DATA POINT LIBRARY Pase 2 of 60 DATA POINT LIBRARY REFERENCE FI1JI Date: 01/07/92 Reactor Unit M01 Data Feeder PCS NRC ERDS Parameter NI POVER RNG Point ID - C51C4001-Plant Spec Point Desc.: AVERAGE CONSISTENT APRM READING Generic /Cond Dese.: NUCLEAR INSTRUMENTS, POVER RANGE Analog / Digital 4 Engr-Units / Dig Statess Engr Units Conversion: N/A Minimum Instr Range 0 Maximum Instr Range: 125 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 12 How Processed: AVERAGE OF CONSISTENT APRHS Sensor Locations APRM UTILIZE 24 LPRMS LOCATED IN-CORE Alarm / Trip Set Polntst. .HI-HI TRIP =(.58V+62%),V %RECIRC FLOV 4 NI Detector Power Supply N/A Cut-off Pover Level: NI Detector Pover_ Supply N/A Turn-on Power Levels Instrument Failure Mode DOVNSCALE(3%),INOP, BYPASS Temperature Compensation N/A-For DP Transmitters: Level Reference Leg: N/A Unique System Desc.: This point consists of either an' average of all consistent APRMs or-an average of in-range APRMs if-there are less than the required number of consistent signals. APRMS(Average Power Range Monitors) consist of an average of 24 LPRMs (Local Power Range _Honitors). Each' individual APRM signal vill-fail on Dovnscale(3%), Inop, or Bypass. HI-HI. trip. feed RPS SCRAM for one-out-of-three-tvice logic. HI trip (.58V+50%) results.in Rod _ Vithdrav Block. s L Il L R

NSP MONTICEL14 NUCLEAR GENERATING PLANT EROS-SRS-2-B ERDS DATA POINT LIBRARY Page 2 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Peeder PCS NRC ERDS Parameter NI POVER RNG Point ID: C5104001 Plant Spec Point Desc.: AVERAGE CONSISTENT APRM READING Generic /Cond Desc.: NUCLEAR INSTRUMENTS, POVER RANGE Analog / Digital A Engr Units / Dig States Engr Units Conversion: N/A Minimum Instr Range: 0 Haximum Instr Range: 125 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 12 How Processed: AVERAGE OF CONSISTENT APRHS Sensor Location: APRM UTILIZE 24 LPRHS LOCATED IN CORE Alarm / Trip Set Points: HI-HI TRIP =(.58V+62%),V=%RECIRC FLOV NI Detector Power Supply N/A Cut-off Pover Level NI Detector Power Supply N/A Turn-on Power Levels Instrument Failure Mode: DOVNSCALE(3%),1NOP BYPASS Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: This point consists of either an average of all consistent APRMs or an average of in-range APRMs if.there are less than the required number of consistent signals. APRHS(Average Power Range Monitors) consist of an average of'24 LPRMs (Local Power Range Monitors). Each individual APRH signal vill fail on Dovnscale(3%), Inop, or Bypass. HI-HI trip feed RPS SCRAM for one-out-of-three-twice logic. HI trip (.58V+50%) results in Rod Vithdrav Block. l l

'J [ NSF NOIFTICRLLO NUCLEAR GENERATING PIANT ERDS-BRS-2-5 ERDS DATA Pollrr LIBRARY-Pange 3 of 60 i l . DATA POIlfr LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit M01 Data Feeders. PCS e NRC FRDS Parameter NI INTER RNG Point ID: .l Plant Spec Point Desc.: (not available) Generic /Cond Desc.: NUCLEAR INSTRUMENTS, INTERMEDIATE RANGE Analog / Digital ' 93r Units / Dig States: Engr Units conversions. Minimum Instr. Ranges Maximum Instr Ranges Zero Point Refarences Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Location: Alarm / Trip Set Points: NI Detector Power Supply Cut-off Pover Levels .NI' Detector Power Supply Turn-on Power Levels-Instrument Failure Mode: Temperature Compensation -i For DP Transmitters: Level Reference Legs Unique System Desc.: Not available to Process cop) uter System. l E we'7-pa , p y 3 ,aq isa..c w -9 g g a 9 y A y 9 9g 9 yywy y m-w or-wrve

NSP MONTICELLO NUCLEAR GENERATING PLAKr ERDS DATA POINT LIBRARY ERDS-SRS-2-B Page 4 of 60 DATA POINT LIERARY REFERENCE FILE I Date: 01/07/92 Reacter Unit H01 Data Feeder: PCS NRC ERDS Parameter NI SOURC RNG Point ID: Plant Spec Point Desc.: (not available) Generic /Cond Dese. NUCLEAR INSTRUMENTS, SOURCE RANGE Analog / Digital Engr Units / Dig States: ^ Engr Units Conversion Hinimum Instr Ranges Maximum Instr Rangs: Zero Point Reference Reference Point Notes: PROC or SENS: Number of Sensors How Processed: Sensor Location: Alarm / Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Levels Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Dese.: Not available to Process Computer System. ^ ~ - ~ ~^

.p, NSP MONTICELLO NUCLRAR-GENERATING PLWP -ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 5 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit M01 Data Feeder: PCS NRC ERDS Parameter: REAC VES LEV Point ID: B2100010 Plant Spec Point Dese.: RPV VALIDATED VATER LEVEL Generic /Cond Desc.: REACTOR VESSEL VATER LEVEL Analog / Digital A Engr Units / Dig States: INCHES Engr Units Conversion: N/A Minimum Instr Range: -350 Haximum Instr Range: 350 Zero Point

Reference:

MSSKRT Reference Point Notes: 0" CORRESPONDS TO 126" ABOVE TOP OF FUEL PROC or SENS: P Number of Sensors: 28 Hov Processed: VEIGHrdu AVERAGE OF CONSISTENT LEVELS Sensor Location: LEVEL SE? LEGS - 5 HOT (IN DV) & 2 COLD Alarm / Trip Set Points: -48"=ECCS INIT, 9"-SCRAM, 48"=HI TRIP NI Detector Power Supply N/A Cut-off Power Level: NI Detector.Pover Supply N/A Turn-on Power Level Instrument Failure Mode: +280" TOP OF REACTOR HEAD Temperature Compensation N/A For DP Transmitters: Level Reference Leg VET Unique System Desc.: This point consists of either a weighted average of all consistent leve) indicators or an average of in-range level indicators if there are less than the required number of consistent signals. Algorithm performs temperature compensation and evaluates reference leg flashing on 7 level signals. Safeguards Levels (-50" to 50") utilize cold reference leg design outside of dryvell. ECCS levels (-335" to 65") are invalidated with rectre pumps running. Other levels include 2 teedvater (0 to 60") and 1 vessel flood (-50" to 350"), m

NSF NONTICELLO NUCLEAR GENERATING PLANP ERDSASRS-2-B i ERDS DATA POINT LIBRARY Page 6 of'60 DATA POINT LIBRARY REFERENCE FILE Date: 01/19/93 i Reactor Unit: M01 Data Feeders. PCS NRC ERDS Parameter: RCS PRESSURE Point ID: B21C0210 Plant Spec Point Desc.: RPV VALIDATED PRESSURE Generic /Cond Desc.: REACTOR COOLANT SYSTEM PRESSURE. Analog / Digital-A Engr Units / Dig States: PSIG Engr Units Conversion: N/A Minimum Instr Range: 0.00 Maximum Instr Range: 1500 Zero Point

Reference:

N/A Reference Point Notes: N/A i PROC or SENS: P Number of Sensors: 3 How Processed: VEIGHTED AVERAGE OF CONSISTENT LEVELS' Sensor Location: PRESSURE SENSED OFF LEVEL REF. LEGS-Alarm / Trip Set Points: 1056 PSIG= SCRAM NI Detector Pover Supply N/A Cut-off Power Level NI Detector Power Supply N/A-Turn-on Power Level: Instrument Failure Mode: HI/LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Dese.: This point consists of either a veighted; average of all consistent-pressure. indicators or an! average of in-range; pressure level indicators:if-there are less-than the= required number of consistentisignals. e

e. NSP MONTICELLO NUCLEAR GENERATING PLANT ERDS-SRS-2-B s ERDS DATA POINT LIBRARY Page 7 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 Resctor Unit: H01 Data Feeder: PCS NRC ERDS Parameter: HAIN FD FLOV Point ID: C51C9001 Plant Spec Point Desc.: SH00THED FEEDVATER FLOV LOOP A Generic /Cond Desc.: FEEDVATER FLOV INTO THE REACTOR SYSTEM. Analog / Digital A Engr Units / Dig States: HLB /HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 4 Zero Point

Reference:

N,* A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 4 How Processed: SH00THED FV FLOV CALC FROM A N0ZZLE D/P Sensor Location: FV N0ZZLE IS DOVNSTREAM OF RX FE PUMPS Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Mode HI/LOV SENSOR Temperature Compensation N/A For DP Transmitters: N/A Level Reference Leg N/A Unique System Desc.: SH00THED FV FLOV LOOT A is calculated using Feedvater nozzle D/P, Pressure, and temperature. Smoothing algorithm sums 1/12 current sample + 11/12 of previous smoothed value. Sampling frequency is 5 seconds. Feedvater nozzles are located downstream of Reactor Feedvater Pumps-and ahead of high pressure heaters.

1? 9 NSF NONTICRLLO NUCLEAR GENERATING PLANT ERDS-SRS-2-B:: ERDS DATA POINT LIBRARY' - Page 8:of 60-v n ~ DATA' POINT LIBRARY REFERENCE FILE Date: 01/07/92. Reactor Units M01. Data Feeder: PCS NRC-ERDS Parameter MAIN FD FLOV-4 Point ID: C5109002 -Plant Spec _ Point Dese.: SMOOTHED FEEDVATER-FLOV LOOP B Generic /Cond Desc.: FEEDWATER FLOV INTO THE REACTOR: SYSTEM Analog / Digital. A Engr Units / Dig States: MLB/HR-Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr-Range: 4 Zero Point References-N/A Reference Point Notes: N/A PROC or'SENS: P Number of Sensors: 4 How Processed: SMOOTHED FV FLOV CALC FROM B~N0ZZLE D/P Sensor Locations-FV N0ZZLE IS DOWNSTREAM OF RX-FV PUMPS Alarm / Trip Set. Points:- N/A NI Detector Pover. Supply. N/A Cut-off Power Level NI Detector'Pover Supply 1 N/A. Turn-on Pover Level Instrument Failure.Hode: HI/LOV SENSOR Temperature Compensation N/A. For DP Transmitters: N/A Level Reference. Legs. N/A-Unique System Desc.: , SMOOTHED _FV'FLOV LOOP B is calculated. using Feedvater' nozzle D/P, Pressure,'~and temperature. Smoothing algorithm. sums-I/12 current sample + 11/12 of: previous smoothed value.LSampling: frequency is 5; seconds.: Feedvater: nozzles are located = downstream of' Reactor Feedvater Pumps:and ahead of high pressure heaters.- w I t

w- -M NSP M0ffrICELLO NUCLEAR GENERATING PLANT-ERDS-SRS-2-B-ERDS DATA POINT LIBRARY = - Page 9 of 60 ' -DATA POINT LIBRARY REFERENCE FILE' Date:1 01/19/93-Reactor Unit H01 Data Feeders-PCS NRC ERDS Parameter: HPCI FLOV Point ids. HPC100 Plant. Spec Point Desc.: HPCI PUMP DISCRARGE FLOV. ^ Generic /Cond Desc. ' HIGH PRESSURE COOLANT INJECTION;FLOV_ Analog / Digital A Engr Units / Dig States: GPM Engr Units Conversion: N/A-Minimum-Instr Range: 0 Maximum Instr Range: 3500 ~ Zero Point.

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL INPUT FROM FLOV TRANSMITTER Sensor Location: FLOV ELEMENT ON HPCI PUMP DISHARGE, Alarm / Trip Set' Points: N/A' NI-Detector Power Supply-N/A. Cut-off Power Level NI Detector Pover. Supply N/A Turn-on Power Level Instrument Failure Mode HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: N/A Level Reference Leg: N/A-Unique System Desc. -- HPCI is-a steam-turbine' driven pump designed.to deliver 2700 gpm:over--reactor: pressure-ranLa.of;150-ll20.psig. Flov element-is located;on pump disharge line- = ahead of.'the test: return'line to.the CSTE E tanksiand injection line into1"B"i feedvatercline.'HPCI' injects into-feedvater=line prior:to;the'line entering containment. .i 'l r. n ~

NSP MONTICEL1h NUCLEAR GENERATING PIhfT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 10 of 60- $b DATA POINF LIBRARY REFERENCE FILE-. l Date: 01/07/92 Reactor Unit: M01' Data Feeder: PCS NRC ERDS Parameters-RCIC FLOW Point'ID _ RCIl00 Plant Spec Point Desc.: RCIC PUMP DISCHARGE FLOV Generic /Cond Desc.: REACTOR CORE ISOLATION COOLING Analog / Digital A Engr Units / Dig States: GPM Engr Units _ Conversion: N/A Minimum Instr Range 0 Maximum Instr Range: 500-Zero Point

Reference:

N/A Reference Point Notta: N/A PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL INPUT FROM FLOV TRANSMITTER Sensor Location: FLOW ELEMENT ON RCIC PUMPLDISHARGE-Alarm / Trip Set Pointsi. N/A NI Detector Power' Supply' N/A -Cut-off Power Levels-NI Detector Power Supply N/A Turn-on~ Power Levels Instrument-Failure Mode HIGH & LOW SENSOR Temperature Compensation N/A For DP Transmitters: N/A. Level Reference Leg: N/A -Unique-System Dese.: RCIC is~a steamLturbine driven pump designed to deliver 400:gpm over reactor pressure range of. 150-1120 psig. Flow-elementLis' located _on~ pump disharge line-ahead of'theftest-return line to the CST'- tanks andLinjection line into "A"-- feedvater line. RCIC injects into 'feedvater line prior to the line-entering. containment. l l i

.7. o.7 iNSP MONTICELLO NUCLEAR GENERATING PIANT ~ ERDSLSRS-2-5: v ERDS DATA POINr LIBRARY- -Page 11 of~60 DATA POINT LIBRARY

REFERENCE:

FILE' -i -Dates: 01/07/92 Reactor Unit M01 Data Feeders PCS NRC ERDS: Parameter ~LPCI FLOV-Point-ID: RHR100 Plant Spec Point Desc.: CONTAINMENT: SPRAY / COOLING A LOOP 9 Generic /Cond Desc. - LOV PRESSURE COOLANT INJECTION FLOV-Analog / Digital A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range 0 g Maximum Instr Ranges. 10000 Zero Point

Reference:

N/A Reference Point Notes: N/A -PROC or SENSt. S -Number of. Sensors: 1 How Processed: SIGNAL INPUT FROM FLOV TRANSMITTER Sensor Location: DISCHARGE OF RHR HEAT EXCHANGERS Alarm / Trip Set Points:- N/A- ~ NI Detector Power Supply N/A' Cut-off-Power Level:1 NI-Detector, Power Supply N/A Turn-on Power Levels Instrument Failure Mode HIGH & LOV SENSOR 'l Temperature Compensation N/A For DP Transmitters: N/A Level Reference Leg N/A-o Unique System Desc.: CONTAINMENT SPRAY / COOLING A LOOP,flov is the RHR flow:to theA: loop'dryvell/ spray,. torus spray-and torus. cooling.7 Each RHR pumpris approximately rated:at 4000'gpmL a depending:on systemihead. Two pumps.are -located:in~each11oop althoughiflow?can be= . cross tied between'A:and B. loops., q j 1 j

-.u.

.--E- ~- w -,.A'

a ': ,J

NSP MOMICELLO NUCLEAR GENERATING PLANTo-ERDS-SRS-2-B1 ERDS DATA POINT LIBRARY-

"Page:12 of 60-si DATA POIM LIBRARY REFERENCE FILE' i -Dates, 01/07/92 -Reactor Unit: M01' Data Feeder PCS NRC ERDS Parameter: LPCI FLOV Point ID: RHR101 Plant Spec Point Desc.: CONTAINMENT SPRAY / COOLING:B LOOP: Generic /Cond Desc.: LOV PRESSURE COOLANT INJECTION FLOV ' Analog / Digital A Engr Units / Dig States GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 10000' Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or-SENS: S Number of Sensors: 1 Hov Processed:- SIGNAL INPUT FROM FLOV TRANSMITTER ~ Sensor Location: DISCHARGE OF RHR HEAT EXCHANGERS ~ Alare/ Trip Set _Pointst. _N/A NI Detector. Power Supply N/A Cut-offLPower Level NI Detector:-Pover~ Supply-N/A Turn-on Power Level: Instrument Failure Modes HIGH & LOW SENSOR Temperature Compensation N/A For DP Transmitters: N/A. Level Reference Leg: N/A Unique System Dese.: CONTAINMENT SPRAY / COOLING'B4 LOOP ~flov is the RER flov'_to'the B loop dryvell spray, ~ torus'. spray and. torus._ cooling.- Each RHRJ pump is approximately_ rated'at 4000 gpm1 ~ depending-on:systemihead.1Two pumps are: located in~eacheloop although1 flow can be e cross-tied between.A and Bl loops.. s-

4..

NSP NONTICELLO NUCLEAR CENERATING PLANT I ERDS-SRS-2-Bc 1

'ERDS DATA POINT LIBRARY' Page 13 of:60 ' DATA POINT LIBRARY REFERENCE = FILE Dates 01/07/92 Reactor Unit M01-Data Feeder: PCS NRC ERDS Parameters LPCI FLOV Point ID: -RHR102-Plant Spec Point Desc.: RHR LOOP A INJECT FLOV Generic /Cond Desc.: LOV_ PRESSURE COOLANT INJECTION FLOV_ Analog / Digital A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum ~ Instr Range: 0 Maximum-Instr Range: 10000 Zero Point

Reference:

N/A Reference. Point Notes:- N/A-PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL INPUT FROM FLOV TRANSMITTER-Sensor Location: DISCHARGE OF RHR HEAT EXCHANGERS-Alarm / Trip' Set Points: N/A NI Detector Pover_ Supply N/A Cut-off. Power Level NI Detectot Power. Supply N/A Turn-on Power Level Instrument Failure Mode: HIGH & LOV SENSOR Temperature _ Compensation-N/A' For DP Transmitters: -N/A Level Reference Leg: N/A Unique' System Desc.: RHR LOOP A-INJECT FLOV is the RHR(flow to= a .the A Recire Loop, Reactor Head Cooling, Vaste Surge Tank,.and. cross _ tie to'B-Loop.- Each RHR= pump is rated _ at._about - 4000 gpm1 depending onisystem head. Two pumps are locatednin eachiloopialthough; ? -flov can'be cross tied between.A:and B loops._ w - e p d-mm W

NSP MOPfrICELLO NUCLEAR GENERATING PLAlq ERDS-SRS-2-B = ERDS DATA POINT LIBRARY Page 14 of 60 DATA POIIC LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder PCS NRC ERDS Parameter: LPCI FLOV Point ID: RHR103 Plant Spec Point Desc.: RHR LOOP B INJECT FLOV Generic /Cond Desc.: LOV PRESSURE COOLANT INJECTION FLOV Analog / Digital A Engr Units / Dig States: GPH Engr Units Conversion: N/A Minimum Instr Range: 0 Haximum Instr Range 10000 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL INPUT FRCH FLOV TRANSHITTER Sensor Location: DISCllARGE OF RHK HEAT EXCHANGERS Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level: NI Detector Power Supply. N/A Turn-on Power Level: Instrument Failure Mode HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: N/A Level Reference Lega N/A Unique System Desc.: RHR LOOP B INJECT FLOV is the RHR flow to the B Recire Loop and cross tie to A Loop. Each RHR pump is rated at about 4000 gpm depending on system head. Two pumps are located in each loop although flow can be cross tied between A and B' loops.

L 7 'NSP MONTICELLO NUCLEAR GENERATING'PI M r' ERDS-SRS-2-5 ERDS DATA POINT LIBRART-Page 15 of 60-1 -DATA POINT LIBRARY REFERENCE FILE Dates 01/07/92 Reactor Units-M01-Data-Feeder PCS NRC ERDS Parameter CR SPRAY FL Point ID: CSP 100 Plant Spec-Point Desc.:- CS LOOP 11 FLOV-Generic /Cond Dese. ~ Core Spray Cooling. System Flow Analog / Digital A Engr Units / Dig-States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 5000 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENSt-S Number of Sensors: 1 How. Processed: SIGNAL INPUT FROM FLOV TRANSMITTER Sensor-Locations-ON PUMP DISCHARGE LINE. Alarm / Trip Set' Points: NI Detector Power' Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Modes. HIGH & LOV SENSOR -Temperature Compensation. N/A For'DP Transmitters: Level Reference Leg: N/A Unique System Desc.: The loop A Core Spray system. consists =of one electric driven pumpfdesigned to_ deliver 3020 gpm against a system head corresponding to a reactor: pressure of 130 psi-above containment' pressure.-The flow element _is located on-the pump _ discharge line just a head of the reactor vessel injection and test return lines.

D -NSF NO MICELLO NUCLEAR GENERATING PLANT ERDS-SRS-2-B ERDS DATA POINT-LIBRARY-Page--16 of 60 -DATA POIM LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit: M01 ~ Data Feeder: PCS-NRC ERDS Parameter CR' SPRAY FL Point ID: CSP 101 Plant Spec Point Dese.: CS LOOP 12-FLOV Generic /Cond Desc.:- CORE SPRAY COOLING SYSTEM FLOV Analog / Digital A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 ~ Maximum Instr Range: 5000 Zero Point'

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of= Sensors: 1 How Processed: SIGNAL-INPUT FROM FLOW TRANSMITTER Sensor Location: ON PUMP DISCHARGE LINE Alarm / Trip Set _ Points: NI Detector Power-Supply N/A-Cut-off Pover Level: NI Detector Power Supply _ N/A Turn-on Power Levels -Instrument Failure Mode HIGH-&-LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg: N/A Unique System Desc.: The loop B Core Spray system: consists of-one electric-driven pump designed =to deliver 3020~gpm against a system head corresponding to a-reactor pressure of _i 130 psi above containment _ pressure. The i flov element is-located _on.the pump discharge line just a head of the reactor -vessel 1 injection ~and test return lines. -1 -l 'j

~ -lNSP MONTICELIA NUCLEAR GENERATING PL NTE ERDS-SRS-2-B A ERDS DATA Pollff LIBRARY-Page 17 of 60' DATA POINT LIBRARY REFERENCE FILE -Date: 01/07/92 Reactor Unit H01 Data Feeder PCS NRC ERDS Parameter DV FD SMP LV Point ID: PCT 138 Plant Spec Foint Desc.: DV EQUIP DRAIN SUMP VOL Generic /Cond Dese.: DRYVELL FLOOR DRAIN SUMP LEVEL Analog / Digital A Engr Units / Dig-States: GAL Engr Units Conversion: N/A Minimum Instr Range: 114.4 Maximum Instr Range: 514.8 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENS: S -Number of Sensors: 1 How Processed: SIGNAL INPUT PROM LEVEL TRANSMITTER Sensor Location:- DIRECTLY BELOV RX VESSEL IN DRYVELL ' Alarm / Trip Let Points: _ N/A NI Detector Power' Supply N/A Cut-off Power Level NI Detector Power. Supply' N/A Turn-on Pover Levels ~ Instrument Failure Modes-HIGH & LOV SENSOR-Temperature _ Compensation N/A' For DP' Transmitters:- Level Reference Leg ~ N/AL Unique System Desc.: This sump collects liquid effluent;from valve stem leak-offs, Rx Recirc. Pump and= piping maintenance drains,: vent cooler drains, reactor.vell-bulkhead and bellows-drains, reactor! vessel! flange leakoff and: Dryvell Equipment Drain Sump heat-exchanger drain. Tvo150 GPM pumps-discharge the_ vater to the Vaste: Collector Tank inLthe Reactor building.- Sump is isolated.by. Group II_ Isolation or manually from_ control room. Sump overflovs'into Dryvell' Floor Drain Sump at IU90 Gallons. 4 4 m

,,e NSPMONTICELthNUCLEARGENERATING-PLANT-ERDS-SRS-2-5 = ERDS DATA POINT LIBRARY Page 18-of 60~ DATA POINT LIBRARY REFERENCE FILE -Dates. 01/07/92-Reactor Unit: M01 Data Feeder: PCS - NRC ERDS Parameters . DV FD SMP LV Point-ID: PCT 139 Plant Spec Point Dese. ' DV FLOOR DRAIN SUMP VOL ~ Generic /Cond Desc.: DRYVELL' FLOOR DRAIN SUMP LEVEL' Analog / Digital A Engr Units / Dig States: GAL Engr Units Conversions N/A-Minimum Instr Rangen-114.4 Maximum Instr Range: 514.8 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS:- S Number of Senscrs: 1 How Processed: SIGNAL INPUT FROM LEVEL TRANSMITTER-Sensor Locations' DIRECTLY BELOV RX VESSEL IN DRYVELL i Alarm / Trip-Set Points: N/A NI Detector Power Supply. N/A Cut-off Power. Level: NI Detector Power Supply N/A Turn-on Power Level Instrument' Failure Mode HIGH & LOV SENSOR-Temperature Compensation N/A For DP Transmitters: Level Reference Leg - N/A Unique System Dese.: This sump collects liquid effluent from' Dryvell' cooler-drains, floor drains,- control rod drive leakage,and drains, closed-cooling water piping' drains,=and ^ piping and equipment maintenance-vents. Two=50 GPM pumps. discharge the water to the. Floor: Drain Collector -Tank - in the Reactor building.-SumpLis isolated by Group II-Isolation or manually (fromi control room.' Sump overflows'into Dryvell:- Equipment Drain Sump at 1090 Gallons., -w v w

p - ~ ~ ^ ~-~ ^ 4 ..e NSP NOMICEL14 NUCLEAR GENERATING PLAM 'ERDS-SRS-2-B-- ERDS DATA POIM LIBRARY -PaEe 19 of 60 ~

.4 DATA POIM LIBRARY REFERENCP. FILE Date:

01/07/92 Reactor Unit: M01 Data Feeder: PCS NRC ERDS Parameter EFF GAS RAD-Point-ID: PRM121 Plant Spec Point Dese.: STACK EFF MONITOR CH A Generic /Cond Dese.: RADIOACTIVITY OF RELEASED GASES Analog / Digital-A Engr Units / Dig States: uCI/S-Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 10E12 Zero Point References- .N/A Reference Point Notes: N/A PROC or SENS:- S Number of Sensors: 1 How Processed: SIGNAL FROM ANALOG OUTPUT OF MONITOR Sensor Locations-FOUR IS0 KINETIC PROBES IN OFF GAS STACK Alarm / Trip Set Points: HI-3200, HI-HI-90000 NI-Detector Power-Supply -N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Level: Instrument Failure Modes: HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg: N/A Unique System Desc.: STACK EFF MONITOR CH A is a vide range gas monitor consisting'offisokinetic probe assembly, sample conditioning-unit : sample detection unit, and Control Room

panel.'The detector-assembly consists of; lov,:mid, and high rangefdetectors. Hi-Hi and/or IN0P from both Channel A & B-monitors: vill close valves to isolate off.

gas flov'tolthe stack.- L t

~ 4? 3,, - MSONOWTICEL1h NUCl. EAR GIDfERATING PLANT: ERDS-SRS-2-BL 24 I ERDS DATA POINT LIBRARY- =Page 20 of 60 t DATA POINT LIBRARY REFERENCE FILEi Date:- 01/07/92' Reactor Unit: M01-Data Feeder: PCS NRC ERDS Parameter EFF GAS RAD Point ~ID: PRM122 Plant Spec' Point Desc. : STACK-EFF MONITOR CH B' Generic /Cond Desc.: RADIOACTIVITY OF RELEASED GASES Analog / Digital A-Engr Units / Dig: States:- uCI/S. Engr Units Conversion: N/A~ Minimum Instr Range: 1 Maximum Instr. Range: 10E12 Zero Point

Reference:

N/A Reference' Point Notes: N/A' PROC or SENS: S Number of Sensors:- 1 s How Processed:- SIGNAL FROM ANALOG OUTPUT OF MONITOR' Sensor Locations' FOUR IS0 KINETIC PROBES IN OFF GAS STACK i :t Alarm / Trip Set Points: HI-3200, HI-HI-90000-NI Detector Pover Supply N/A~ ~ Cut-off Pover Level: NI' Detector Power Supply N/A Turn-on Power Level: Instrument Failure Mode: HIGH & LOV SENSOR-Temperature Compensation N/A For DP. Transmitters: Level Reference Leg N/A J Unique System Desc.: STACK EFF MONITOR-CH B:is a1 vide range. gas monitor-consisting of isokinetic-i probe assembly, sample conditioning unit,: sample detection unit, and Control Room panel. The_ detector. assembly; consists of' lov, mid, and high range detectors. Hi-Hi/ and/or.INOP from both Channel.A &'B J monitors vill'elose valves to isolate off-gas flovltc the stack. 4 r u w e

v. s.- NSF NONTICELLO NUCLEAR GENERATING PLArt ERDS-SRS-2-5 ERDS DATA POINT: LIBRARY Page 21 of 60-i DATA POINTILIBRARY REFERENCE FILE Dates. 01/07/92 Reactor Unit M01 Data Feeders-PCS NRC ERDS_ Parameters -EFF GAS RAD Point ID: PRM123 1 Plant Spec Point.Desc.: RBV-EFFLUENT MONITOR CH'A: Generic /Cond Desc.: RADIOACTIVITY OF RELEASED GASES Analog / Digital A Engr Units / Dig-States: uCI/S Engr. Units Conversion: N/A Minimum Instr Range: 1 Maximum Instr Range: 10E12 Zero Point

Reference:

N/A Reference Point Notes: N/A' PROC or SENS: S Number of Sensors: 1 How Processed:-- SIGNAL FROM' ANALOG OUTPUT OF MONITOR, Sensor Locations; - IS0 KINETIC PROBES IN EACH RX BLDG VENT - Alarm / Trip Set Points: HI-400, HI-HI-4500. NI Detector Pover: Supply N/A Cut-off-Power Levels-NI Detector:Pover Supply N/A Turn-on Pover: Level Instrument Failure Modes-ElGH & LOV' SENSOR Temperature Compensation - N//. For DP Transmitters:- Level Reference Leg: N/A' Unique System Dese.: Reactor. Building-Vent 1 Effluent Monitor-Channel A~is-a vide range gas monitor-consisting of isokinetic: probe-assemblies,l sample conditioning. unit, sample detection unit, and control Room. panel..The-detector? assembly 7 consists of lov, mid, and high range detectors. e N w 7 I

~- ' NSP. NONTICBLLO NUCLEAR GENERATING PIANT- 'ERDS-SRS-2-B-ERDS DATA POINT LIERARY ~ Page 22 of 60 DATA POINT LIBRARY REFERENCE FILE-Dates 01/07/92 Reactor Units. M01 Data Feedert PCS NRC ERDS Parameter EFF GAS RAD: Point ids. PRH124 Plant Spec Point Dese.: RBV EFPLUENT MONITOR'CH B Generic /Cond Desc. - RADI0 ACTIVITY OF RELEASED GASES ~ Analog / Digital A Engr Units / Dig States: uCI/S Engr Units Conversion: N/A !!inimum Instr Range: 1 Maximum Instr Range: 10E12 Zero Point

Reference:

N/A Reference Point Notes: N/A 3 PROC or SENS: S Number of Sensors: 1 i Hov-Processed: SIGNAL FROM ANALOG OUTPUT OF MONITOR-Sensor. Location: IS0 KINETIC PROBES.IN EACH RX BLDG VENT i Alarm / Trip Set Points: HI-400, HI-HI-4500-y NI Detector Power Supply N/A- . Cut-off Pover' Level NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Modes HIGH & LOV' SENSOR Temperature Compensation N/A 'I For DP Transmitters: Level 1 Reference Leg: N/A Unique System'Dese.: Reactor Building Vent Effluent Monitor. Channel,Bris~a vide range gas monitor! . consisting;of isokinetic _ probe: i assemblies,. sample 1 conditioning unit,- 4 sample detection unit, Land Control Room-panel =.-The: detector _ assembly consists:of ~* lov, mid,'and high range detectors. o I -l .t

J.i 4 NSP M0lfrICRLIA NUCLEAR GENERATING PLANT ERDS-SRS-2-5. .ERDS' DATA POINT LIBRARY .Page 23 of 60i DATA. POINT [ LIBRARY-REFERENCE FILE, d Dates 01/07/92 Reactor Unit -' H01 -Data; Feeder: PCS NRC ERDS' Parameter: EFF LIO RAD Point ID: PRM107 Plant Spec Point Desc.1-SERVICE VATER EFFLUENT Generic /Cond Desc.: RADI0 ACTIVITY OF RELEASED LIQUIDS Analog / Digital A Engr Units / Dig States: - CPS H Engr Units Conversions uCi/Ml=((PRM107 in CPS)-5)*(4.3E-7)f Minimum Instr Range .1 Maximum Instr Range: 10E6 Zero Point'

Reference:

N/A Reference Point Notes: N/A. PROC or SENS: L S Number of Sensors: 1 Hov Processed:- SIGNAL INPUT FROM MONITOR Sensor Locations; SAMPLES SV PRIOR T0-SV LEAVING:RX~ BLDG Alarm / Trip Set _ Points: HI ALARM AS SET B ' PLANT CHEMIST HI Detector.Pover Supply N/A - Cut-off Power Level NI Detectot Power Supply N/A Turn-on Pover-Level Instrument Failure Modes. DOVNSCALE & UPSCALE-Temperature Compensation ~ N/A For DP Transmitters: Level' Reference' Leg - N/A Unique System Desc.: Gamma radiation emitted by radioactive materials contained in process = liquid are detected by a scintillation detector - housed-in shielded sampler. Sidestream sample is_used from the_ service vater line prior.to leaving:the Reactor-Building.?After leaving Reactor Building, line discharges into cire water discharge pipe.' Alarm setpoints. vary with plant operation as determined by' plant. chemist.: 9 f v 9

+7 ,J NSP MONTICELLO NUCLEAR GENERATING PLANT' ERDS-SRS-2-B ERDS DATA POINT LIBRARY

Page 24~of-60" DATA POINT LIBRARY REFERENCE FILE:

Dates _ 01/07/92 Reactor Unit M01 Data Feeder PCS NRC ERDS-Parameter EPF LIO RAD-Point ID: -PRM109 Plant Spec-_ Point Desc.: --RADVASTE EFFLUENT. Generic /Cond Desc.: RADIOACTIVITY OF~ RELEASED LIQUIDS. Analog / Digital A Engr Units / Dig States: CPS Engr Units Conversions uCi/Ml=((PRM109 in' CPS)-7)*(2.5E-6) Minimum Instr. Range: .1 Maximum Instr Range: 10E6 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: l' Hov Processed: SIGNAL INPUT FROM MONITOR i Sensor Locations-SAMPLED PRIOR TO LEAVING RADVASTE BLDG' Alarm / Trip Set Points: HI ALARM AS SET BY PLANT CHEMIST- -NI Detector Pover Supply _ N/A Cut-off-Power' Level NI Detector; Power Supply N/A Turn-on Power Level: Instrument Failure Mode: D0VNSCALE & UPSCALE, IN0P -Temperature Compensation .N/A-For DP Transmitters: Level Reference Leg N/A Unique-System Desc.: Gamma radiation-emitted by radioactive-materials-contained in process liquid are detected.by a scintillation detector: housed in_ shielded sampler. Liquid._is sampled prior'to leaving the: Radvaste Building.-Afterileaving Radvaste. Building, line discharges:into: discharge canal. Although:Monticello has permits, Monticello maintains _a: policy of zero liquid'radvaste; releases?into the river.. Alarm setpoints vary with plant; operation as determined by plantLehemist.

9 . c;- ' *J ' f2: NSF_ NONTICELIA MUCLEAR GENERATING PLANY ' ERDS-5RS-2-8' ERDS DATA POINT LIBRARY Page 25 of 60' DATA POINT LIBRARY REFERENCE FILE. i Date: 01/07/92 Reactor Unit: M01 L Data Feeder: PCS-NRC ERDS Parameter: EFF LIO RAD Point ID - PRM110 -Plant Spec Point Desc.: TB NORMAL VASTE SUMP CH A Generic /Cond Desc.: RADIOACTIVITY OF RELEASED LIQUIDS Analog / Digital A Engr Units / Dig States: CPM Engr Units Conversions uCi/Hl=((PRM110 in CPM)-400)*(3.5E-9) Minimum Instr Range: 10 Maximum Instr Range: 10E6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S

t Number of Sensors:

1 How Processed: SIGNAL INPUT FROM HONITOR Sensor Location: SAMPLED' PRIOR TO LEAVING TURBINE BLDG Alarm / Trip Set Points: HI ALARM AS SET BY PLANT CHEMIST NI Detector Power Supply N/A Cut-off Power Level: NI Detector Power-Supply Turn-on Power Levels -N/A Instrument Failure Mode: DOVNSCALE & UPSCALE, INOP ._ s Temperature Compensation N/A For DP Transmitters: Level Reference Lega N/A-Unique System Desc.: Gamma-radiation emitted by_ radioactive- ~ -materials contained in' process-liquid are: detected by;a scintillation; detectors in dry z tube in: sump. JSampled prior to leaving.the_ Turbine Building. Alarm-setpoints vary vith'plantfoperationLas determined by plant-chemist. b

e' t NSP NORTICRLIA) NUCLEAR GENERATING' PLANT ERDS-SRS-2-B -

4--

'ERDS DATA POIKr LIBRARY ' Page 26 of 60 / DATA POINT LIBRARY REFERENCE FILEL - Dater-01/07/92-Reactor Unit -M01. Data Feeders- .PCS NRC ERDS. Parameter:_ EFFELIO RAD Point ID:; .PRM111 Plant Spec Point-Dese.:~ TB NORMAL VASTE SUMP CH B-Generic /Cond Desc.: RADIOACTIVITY OF RELEASED LIQUIDS: Analog / Digital A Engr Units / Dig States: CPM Engr Units Conversions uC1/Ml=((PRM111 in CPM)-400)*(3.5E-9) Minimum-Instr Range: 10 ~ Maximum: Instr Range: 10E6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL INPUT FROM MONITOR Sensor Locations SAMPLED' PRIOR TO LEAVING TURBINE BLDG Alarm / Trip Set Points: HI ALARM-AS SET BY_ PLANT CHEMIST. NI Detector Power Supply N/A - Cut-off-Pover Levels. - NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Mode: D0VNSCALE &. UPSCALE, INOP Temperature Compensation N/A For DP Transmitters: Level. Reference Lega W/A Unique System Dese.: Gamma: radiation emitted by: radioactive-materials contained in process: liquid are detected by a scintillation-detectors' int dry 3 tube'in sump. Sampled prior to-leaving the Turbine-Building.RAlarmE setpoints vary vith~plantcoperation'asi determined:by' plant chemist. P' ) a y I, - 4

~ ~NSP MONTICELLA NUCLEAR CENERATING PLANTL -ERDS-SRS-2-B-ERDS DATA' POINT LIBRARY Page 27 of 60i DATA POINT LIBRARY REPERENCE FILE' Dates-01/07/92 Reactor Units-M01-Data Feeders-PCS NRC ERDS Parameters. EFF LIQ RAD Point ID: PRM112 Plant Spec Point Desc.: DISCHARGE CANAL MONITOR A Generic /Cond Desc.: RADIOACTIVITY OF RELEASED LIQUIDS Analog / Digital A Engr Units / Dig States: -CPS Engr Units Conversions uCi/Hl=((PRH112 in CPS)-2)*(1.4E-7)? Minimum Instr Ranges. .1 Maximum Instr Range: 10E6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: .S Number of Sensors: 1 How Processed: SIGNAL INPUT FROM MONITOR Sensor Location: 550FT DOVNSTREAM FROM-DISCHARGE STRUCTURE Alarm / Trip-Set. Points: HI ALARM AS SET BY-PLANT CHEMIST-- NI Detector Pover-Supply .N/A-Cut-off Power Level: NI Detector Power-Supply N/A Turn-on Power Level: Instrument Failure Mode: D0VHSCALE & UPSCALE,-INOP Teeperature Compensation-N/A-For DP Transmitters: Level

Reference:

Leg N/A-Unique System Desc.t Gamma radiation emitted by radioactive-materials contained-in process liquid'are-detected by a-scintillation detectors.- Sample-is drawn from-4-standpipes in canal 550' feet downstream from the discharge structure. Alarm:setpoints; vary : vith plant' operation as determined by-- plant chemist. ~ 4

m . ~.. t ~. .j g [3 --1 ? NSP NONTICBLLO NUCLEAR GENERATING Pl#ff ERDS-SRS-2-5 : 1-s ERDS DATA POIlff LIBRARY- ~ Pase 28 of 60-3 dw ( - DATA POINT LIBRARY. REFERENCE FILE ~ . Dates: - 01/07/92:

+

Reactor Units' M0le Data-Feeder: ' PCS. NRC ERDS Parameters-EFF LIO RAD- ~ .3 -Point:ID:- PRM113 Plant Spec Point Dese. - DISCHARGE CANAL MONITOR'B' ? Generic /Cond Dese.: RADI0 ACTIVITY OFLRELEASED LIQUIDS; Analog / Digital-A Engr Units / Dig States:- CPS Engr Units Conversion:' uC1/Ml=((PRM113-in~ CPS)-2)*(1.4E-7). Minimum Instr Ranges- -.1 Maximum Instr _ Range: 10E6 Zero Point References N/A Reference Point: Notes - N/A PROC or SENS: S ~ Number of Sensors: 1 Hov Processed: - SIGNAL INPUT FROM MONITOR. + 5, LSensor1 Location: 550FT DOWNSTREAM FRON' DISCHARGE STRUCTURE Alarm / Trip. Set Points:

HI ALARM:AS SET BY PLANT CHEMIST:-

-NI Detector Power Supply- - N/A. Cut-off'Pover-Level: NI Detector Pover Supply N/A: Turn-on' Power Levels -Instrument Failure Modes: D0VNSCALE & UPSCALE,LINOP Temperature Compensation-N/A-For DP Transmitters: Level: Reference Lega N/A UniqueLSystem Desc.1-Gamma' radiation emitted:byLradioactive. ^2 materials contcined-in process liquid are: 3 . detected--by;a scintillation 1 detectors'. 1 i Sample'is drawn.from 4Lstandpipes:in-canal 550 feet'downstreamLfromcthet S - discharge 1 structure.l Alarm setpoints vary; a with plant' operation as; determined.by: plant chemist. = ~. s I h W 'W 4 y 4 D c y'w f g" y is 4 M P ES " ".**' ' '

NSP MOMICELIh NUCLEAR GENERATING PLANT - ERDS-SRS-2-Bi ERDS DATA POINT LIBRARY Page 29'of 60-' DATA POINT LIBRARY REFERENCE FILE, 01/07/92 Dates M01 React'or Unit Data Feeder PCS-NRC ERDS Parameter CND A/E RAD Point ID: PRMll8 Plant Spec Point Desc.: OFF GAS CH 1 Generic /Cond Desc.: CONDENSER AIR EJECTOR RADI0 ACTIVITY Analog / Digital A Engr Units / Dig Statest. MR/HR Engr Units Conversion: N/A Minimum Instr Range 1 Maximum Instr Range: L L10E6 Zero Point

Reference:

N/A- = Reference Point Notes: N/A-PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL-0UTPUT FROM HONITOR Sensor Location SAMPLE DRAVN FROM OFF GAS LINE-Alarm / Trip Set Points: TRIP ON BOTH HONITORS UP,DOWN OR INOP NI-Detector Power Supply N/A Cut-off'Pover Level NI Detector l Power Supply N/A Turn-on Power. Level: Instrument-Failure Mode - LOV Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A vaique System Desc.: OFF GAS-CH 1 radiation monitorfis: -positioned. adjacent to.a vertical sample chamber.'A: continuous sample isldravn' --- from the;off gas line downstream from*the Steam? Jet : Air Ejectors 'and ahead of s the - Recombiner trains.3The! sample is monitored after a time delay of approximately 2 minutes to permit-Nitrogen-16 and;0xygen-19.to decay.: Alarm setpoints. vary with plant operation'as determined by plant chemist.- 7

(. . MSP NONTICELLO NUCLEAR GENERATING PLANT' ERDS-SRS-2-BJ E. -- ERDS DATA POINT LIBRARY-Page'30 of?60-DATA POINT.; LIBRARY REFERENCE FILE. Date: 01/07/92= Reactor Unit: M01 Data Feeders-PCS NRC ERDS Parameter: CND A/E RAD -Point ID: PRM119 Plant Spec Point Desc.: OFF GAS CH 2 Generic /Cond Desc.: CONDENSER AIR EJECTOR RADI0 ACTIVITY .i Analog / Digital A r Engr Units / Dig States: HR/HR Engr Units Conversion: N/A Minimum Instr Range 1 Maximum Instr Ranges-10E6 Zero Point References N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 1 o How Processed:- SIGNAL OUTPUT FROM MONITOR ~ Sensor Locations-SAMPLE DOWNSTREAM OF, STEAM-JET = AIR EJECT Alarm / Trip Set Points: TRIP ON-BOTH MONITORS UP,D0VN OR INOP NI Detector Power Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Pover'Levelt Instrument Failure Moder

LOV Temperature Compensation N/A For DP Transmitters:

Level Reference Lega N/A-Unique System Desc.: OFF GAS CH.2 radiation-monitorcisi positioned adjacent to a1verticalisample chamber.iA continuous-sample:is drawn from the off gas-line; downstream from the 7; Steam Jet Air-Ejectors and ahead of othe, Recombiner? trains. TheEsamplevis monitored after a time delay of" approximately 2 minutes:to permit. Nitrogen-16 and Oxygen-19 to decay. Alarm ^ setpoints-vary with plant-operation as -determined by plant chemist. 1 i 2 4 se-'s 2 m

,, n. - Id ' c.- -MSP MONTICRLLO NUCLEAR GENERATING PLANT < cRRDS-SRS-2-B-BRDS DATA POINT LIBRARY-Page 31'of'60 4 DATA. POIFT LISPJ.RY "MEPJD6CE FILE 4 Date: 01/07/92 Reactor Unit M01

Data Feeder PCS 1

NRC ERDS Parameter: DV RAD Point ID ' PCT 109 Plant Spec Point Desc.: DRYVELL' RADIATION CH A - Generic /Cond Desc.: ' RADIATION-LEVEL ~IN-THE DRYWELL Analog / Digital. A Engr Units / Dig States: R/HR Engr Units Conversions-- N/A Minimum Instr Range: 1 s Maximum Instr Range: 10E0 Zero Point

Reference:

N/A Reference-Point Notes: N/A' PROC or SENS: S Num) of Sensors:. 1 Hov c'S;essed: SIGNAL INPUT FROM RADIATION HONITOR Sensor Location: 'DRYWELL 180 DEGREE AZIMUTH AT 944' Alarm / Trip Set Points: HI.50, HI-HI-100 NI Detector Power Supply N/A Cut-off Pover Level NI Detector Power Supply N/A 4 Turn-on Power Level ' Instrument Failure Modes HIGH SENSOR,-INOP-Temperature Compensation N/A For DP Transmitters:. Level Reference Leg: N/A Unique System Desc.: Purpose-is-to provide estimateLof! core-- damage:by measuring-dryvell gamma. radiation fields caused by fission product leakage from the core.KEach-sensor zis an ionizstion-chamber with.an1 a internal U-234 source which gives 1R/HR reading for.operationiverification.. Elevation 944'. is _just belov bot tom-of reactor vessel-(949'). 4 r 6 m

NSP:N00rrICELIA NGCl2AR CENERATING PLAlfr BRDS-SRS-2-5 ERDS_ DATA POINT LIBRARY Page 32 of 60 DATA POINT LIBRART REFERENCE FI12 I Date: 01/07/92 Reactor Units H01 I Data Feeders PCS NRC ERDS Parametor: DV RAD l Point ID: PCT 110 Plant Spec Point Desc.: DRYVELL RADIATION CH B Generic /Cond Dese. RADIATION LEVEL IN THE DRYVELL Analog / Digital 4 Engr-Units / Dig States: R/HR Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum-Instr Range 10E8 Zero Point References N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensorn: 1 How Processed: SIGNAL INPUT FROH RADIATION HONITOR Sensor Location: DRYVELL 0 DEGREE AZIHUTH AT 944'- i Alarm / Trip Set Points: HI.50, HI-HI.100 NI Detector Power Supply N/A Cut-off Power Level NI Detector Power Supply N/A Turn-on Power Levels Insteument' Failure Mode: !!IGH SENSOR, INOP Tet sture Compensation N/,. Pot Transmitters: I' Levs (eference Lega N/A Uniqu System Dese.: Purpose is to provide estimate of_ core damage by monsuring dryvell gamma-radiation fields: caused by, fission. product leakage from the core.-Each sensor is an ionization 1 chamber with an-internal U-234. source which gives 1R/HR' p-- reading for operation verification. L Elevation 944' is just belov bottom of reactor vessel'(949'),= 1' l-t O P ? :---

NSP HONTICELLO NUCLEAR CENERt. TING PLANT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page_ 33 of 60 DATA POI!(T LIBRARY REFERENCE FI!E Date: 01/07/92 Reacter Unit: H01 Data Peeder PCS NRC ERDS Parameter HN STEAH RAD Point ID: Plant Spec Point Dese.: (not available) Generic /Cond Desc.: RADIATION LEVEL OF Tile HAIN STEAM LINE Analog / Digital Engr Units / Dig States: Engr Units Conversion Minimum Inst; Ranges Maximum Instr Range Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: llow Processed: Sensor Location: Alarm / Trip Set Points: N1 Detector Power Supply "it-off Power Levels at Detector Pover Supply Turn-on Power Level Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc.: Not availtble to Process Computer System.

.o NgP MOWflCELth NUCLEAR GENERATING PLANT FJtDS-SR5-2-8 ERDS DATA POINT LIBRARY Page 34 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder PCS NRC ERDS Parameter DV PRESS Point ID: D23C0010 Plant Spec Point Desc.: VALIDATED DRYVELL PRESSURE Generic /Cond Desc.: DRYVELL PRESSURE Analog / Digital A Engr Units / Dig States PSIG Engr Units Conversion: N/A Minimum-Instr Range -5 Maximum; Instr Range 250 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 4 Hov Processed: VEIGHTED AVERAGE OF CONSISTENT DV PRESS Sensor Location: SENSING LINES FROM DRYVELL' Alarm / Trip Set Points: ALARMS LOV 0.1, HIGH 1.5 NI Detector Pover Supply N/A Cut-off Power Level NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Modes HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Lega N/A Unique System Desc.: This point consists of either a.veighted average of all consistent dryvell pressure or an average of.in-range dryvell' pressures if.there are.lers than-the required number of consistent singals..Four dryvell pressure signals-consist:of one narrov range (-2nto 3).- one vide range (0 to 80) and two accident-(-5 to-250) ranges. Veighted averages-produces average that is veighted based on instrument accuracy. Dryvell internal-design pressure is 56 PSIG at 281. Degrees F. At-2 PSIG, RPS-initiates Reactor SCRAM-and Primary Containment Isolation initiates Group 2 & 3.: I

~. NSP MONTICELLO NUCl.RAR CENERATING PLANT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 35 of 60 DATA POIlfr LIBRARY REFERENCE PILE Date: 01/07/92 Reactor Unit H01 Data Feeder' PCS NRC ERDS Par 6 4ter: DV TEMP Point ID: D23CO310 Plant Spec Point Dese.: VALIDATED DRYVELL TEMPERATURE Generic /Cond Desc.: LRYVELL TEMPERATURE Analog / Digital A Engr Units / Dig Statest DEGF Engr Units Conversion: N/A Minimum Instr Range: 32 Haximum Instr Range: 400 Zero Point References N/A Reference Point Hotes: N/A PROC or SF.NS: P Number of Sensors: 16 Ilov Processed: AVERAGE OF CONSISTENT DV TEMPERAURES Sensor Lo'ation: 16 SENSORS AT 8 DRYVELL LOCATIONS Alarm / Trip Set Points: 111-150 DEGP NI Detector Power Supply N/A cut-off Power Level HI Detector Pover Supply N/A Turn-on Power Levels Instrument Failure Modet ilIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: This point consists of either a veighted average bulk temperature of consistent regional temperatures or an unvalidated, non-veighted average of all in-range dryvell temperatures. Regional weighting factors compensate for differences in dryvell volume at the various elevations. Each location utilizes two sensors and are located in Dryvell at Elev 932' (East & Vest), Elev 951'(North & South), Elev 970' (East & Vest), and Elev 994'(North & South). 1

l + NSF NONTICE!JA NUCLEAR GENERATING PLANT EROS-BRS-2-B _ERDS DATA POINT LIBRARY Page 36 of 60 _ ~ ! DATA POINT LIBRARY RRFERENCE FILE ] i Dates 01/07/92 Reactor Unit: M01 Data Feeder: PCS i NRC ERDS Parameter SP TEMP .i Point IDt D23C0410 Plant Spec Point Desc.: VALIDATED TORUS TEMPERATURE Generic /Cond Desc.: SUPPRESSION P00L' TEMPERATURE Analog / Digital A i Engr Units / Dig States: DEGP Engr Units Conversions-N/A Minimum Instr Range: 30 Haximum Instr Rangen -230 Zero Point-

Reference:

N/A i Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 16 How Processed: AVERAGE OF 2 SPOTHOS (8 SENSORS EACH) Sensor Location 2 SENSORS IN EACH OF 8 TORUS SRV BAYS Alarm / Trip Set Pointsi HIGH 90 NI Detector Pover Supply N/A Cut-off Power Levels 1 NI Detector Power Supply N/A ) Turn-on Power Levels Instrument Pailure Hoce: HIGH & LOV SENSOR, SPOTMOS INOP~ Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: VALIDATED TORUS TEMPERATURE is the average.of the inputs from two. Suppression Pool Temperature MonitoringL Systems (SPOTMOS). Each system' generates an average.of eight> sensors._Each sensor is located in-one of.the eight bays that. Safety Relief Valves-discharge'into. _,y r t f ')

NSF NONTICBLIA NUCLEAR GENERATING F1 ANT ERDS-5RS-2iB ERDS_ DATA POINT LIRRARY Pese 37 of 60, DATA POINP LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit M01 Data Feeders PCS NRC ERDS Parameter: SP LEVEL Point ID: G43C0015 Plant Spec Point Desc.: VALIDATED TORUS VATER LEVEL Generic /Cond Desc.: SUPPRESSION POOL VATER LEVEL Analog / Digital A Engr Units / Dig States: INCHES Engr Units Conversion: N/A Minimum Instr-Ranges -96 Haximum Instr Range 180 Zero Point References N/A Reference Point Notes: 0"= ELEVATION 910'. 530,000 GALLONS PROC or SENS: P Number of Sensors: 4 Hov Processed: VEIGHTED AVERAGE OF CONSISTENT LEVELS Sensor Location: LEVEL TAPS OFF TORUS SHELL Alarm / Trip Set Points: HIGH 2, LO=-2 NI Detector Power Supply N/A Cut-off Power Level NI Detector Power Supply N/A Turn-on Power Level: Instrument Failure Modes HIGH & LOV SENSOR Temperature ~ compensation-N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: This point consists of either a weighted average of all consistent torus water levels or an average of in-range : torus-vater levels if there are less than the required number of consister.t. signals. Four torus Vater level signals consist of. two narrow tange (-15 to 15) and two vide range _(-96;to 180)._Veighted averages? produce an average that is based:on instrument accuracy. HPCI suction: transfer occurs at 2". Tech Specs level greater.than -4" and less than 2.9". 4

NSF MONTICRLIA NUCLEAR GENERATING PIANT RRDS-SRS-2-B + . ERDS DATA POINT LIBRARY Page_38 of 60 DATA POINT LIBRARY REFERENCE PILE Date: 01/07/92 Reactor Unit H01 Data Feeder PCS NRC ERDS Parameter H2' CONC Point ID: PCT 116 Plant Spec Point Desc.: PCTHT H2 ANALYZER A Generic /Cond Desc.: DRYVELL OR TORUS HYDROGEN CONCENTRATION Analog / Digital A Engr Units / Dig States Engr Units Conversion: N/A Minimum Instr Range 0 Maximum Instr Range: 20 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Humber of Sensors: 1: Hov Process (de SIGNAL OUTPUT FROM H2 ANALYZER Sensor Location: SAMPLE LINES UPPER DV, TORUS.CGCS IN & OUT; <y Alarm / Trip Set Points: N/A NI Detector Power F" ply N/A Cut-off Power Level. NI Detector Power Supply N/A Turn-on Power Levels Instrument Failure Modes HIGH & LOV SENSOR, SYSTEM OFF Temperature Compensation N/A For DP. Transmitters: Level Reference Leg N/A Unique System Dese.: Analyzers are normally: shutdown'and values vill usually-read less than 0.75%. System'is capable'of analyzing samples 'from Dryvell-(elev 994')s Torus and. Combustible Gas control = System inlet.and outlet.. Sample line and~ sample' return valves close on Group 2-Isolation.-

I a NSP M0ffrICELLO NUCLEAR CENERATING PLANT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 39 of 60 DATA P01tff LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder: PCS NRC ERDS Parameter: H2 CONC Point IDt PCT 117 Plant Spec Point Desc.: PCTHT H2 ANALYZER B Generic /Cond Dese.: DRYVELL OR TORUS HYDROGEN CONCENTRATION Analog / Digital A Engr Units / Dig States Engr Units Conversion: N/A Minimum Instr Range 0 Maximum Instr Range: 20 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 1 How Processed: SIGNAL OUTPUT FROM H2 ANALYZER Sensor Location SAMPLE LINES UPPER DV TORUS,CGCS IN & OUT Alarm / Trip Set Points: N/A HI Detector Power Supply N/A cut-off Power Level: NI Detector Pover Supply N/A Turn-on Power Level Instrument Failure Mode HIGH & LOV SENSOR, SYSTEM OFF Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: Analyzers are normally shutdown and values vill usually read less than 0.75%. System is capable of analyzing samples from Dryvell (elev 994') Torus and Combustible Gas Control System inlet and outlet. Sample line and sample return valves close on Group 2 Isolation. s

E 1 MSP MONTICEL14 NUCLEAR GetERATING PIANT ERDS-SAS-2-R i ERDS DATA POINT LIBRARY Page 40 of 60

l DATA POINT LIBRARY REFERENCE FILE Date:

01/07/92 Reactor Unit M01 Data Feeder PCS NRC ERDS Parameter: H2 CONC Point ID: PCT 118 Plant Spec Point Desc.: PCTMT 02 ANALYZER A j Generic /Cond Dese.: DRYVELL OR TORUS HYDROGEN CONCENTRATION Analog / Digital A Engr Units / Dig States: l Engr Units Conversion: N/A i Minimum Instr Range 0 Maximum Instr Range: 25 Zero Point Reference - N/A Reference Point Notes: N/A i PROC or~SENS: S Number of Sensors: 1 e Hov Processed: SIGNAL OUTPUT FROM 02 ANALYZER Sensor Location: SAMPLE LINES UPPER DV, TORUS,CGCS IN & OUT Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level NI Detector Power Supply N/A Turn-on Power Levels. Instrument Failure Mode HIGH & LOV SENSOR, SYSTEM OFF Temperature Compensation N/A Por DP Transmitters: Level Reference Leg N/A Unique System Dese.: Analyzers are normally shutdown and values vill usually read less than 0.75%.- System is capable of analyzing samples from Dryvell (elev 994'), Torus and Combustible Gas control: System inlet and outlet. Sample line and sample return valves close:on Group 2 Isolation.: Normal-a operation concentrations are 2.4%.- i

l I. NSP MONTICEL14 NUCLEAR GENERATING PLANT ERDS-SRS-2-B ERDS DATA POIRT LIBRARY Page 41 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder: PCS NRC ERDS Parameter: H2 CONC Point ID: PCT 119 Plant Spec Point Desc.: PCTMT 02 ANALYZER B Generic /Cond Desc.: DRYVELL OR TORUS HYDROGEN CONCENTRATION Analog / Digital A Engr tinits/ Dig States: Engr Units Conversion: N/A Minimum Instr Range 0 Haximum Instr Range: 25 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 1 llow Processed: SIG!!AL OUTPUT FROM 02 ANALYZER Sensor Location: SAMPLE LINES UPPER DV, TORUS,CGCS IN & OUT Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Modes HIGH & LOV SENSOR SYSTEM OFF Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Dese.: Analyzers are normally shutdown and values vill usually read less than 0.75%. System is capable of analyzing samples from Dryvell (elev 994'), Torus and Combustible Gas Control System inlet and outlet. Sample line and sample return valves close on Group 2 Isolation. Normal operation concentrations are 2.4%. I. -h_ _______m -_____.___A,

F = NSF MOIFFICEL1A NUCl2AR GENERATING PLANT ERDS-8RS-2-3.. ERDS DATA POINT LIBRARY Pese 42 of 60 DATA Pollfr LIBRARY-REFERENCE FI12 Date: 01/07/92 Reactor Unit: M01 Data Feeder: PCS NRC.ERDS Parameter: CST LEVEL Point ID: CST 100 Flant Spec Point Desc.: CST TANK LEVEL A . Generic /Cond Desc.: CONDENSATE STORAGE TANK LEVEL-Analog / Digital A Engr Units / Dig States: FEET Engr Units Conversion N/A -Hinimum Instr Range: 5 Maximum Instr Range: 25 Zero-Point Reference N/A Reference Point Notes: N/A PROC or SENS: S-Number of Sensors:= 1 r How Processed: SIGNAL FROM LEVEL TRANSHITTER Sensor. Location LEVEL TX ON VATER COLUMUN IN RX BLDG g Alarm / Trip Set Points: HI-24'(226,100 gal) LO.11.5'(108,400 gal) NI Detector Pover Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Levels-Instrument Failure Mode: LOV TemperatureLCompensation N/A For DP Transmitters: Level Reference Leg N/A. Unique System Desc.: Condensate Storage. Tank'(CST)" Level A-is: the water level.inLthe A CST. Two CSTs- ,a exisC vith'a tank capacity of-230,000 ~ gallons each. Makeup condensate' vater is providedLthrough 3 electric: pumps from; the CST. tanks 1to various plant systemsL Each tank has' auction line'for Control Rod Drive, HPCI, Core-Spray,JRHk,:and RCIC systems.: : At^7'(65 800 gal) receive ' CST Low-Lov Level alarm and condensateL - pumps _ trip. fat-_2'(18,800 gal) HPCI transfers to TorusJsuction,; Core Spray 1 and RHR are normally lined ~up-to the CSTs._ e t 4 a ww.; .-..,e.. 3 m e. w.-


.~.,-,w.

e , a.. rm e w n.+ , ~ , w m,.,-, ,4M,+ .rce -.-.o er,

NSP M0ffflCELLO NUCLEAR GENERATINC PLAlff ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 43 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder: PCS NRC ERDS Parameter CST LEVEL Point ID: CST 101 Plant Spec Point Desc.: CST TANK LEVEL B Generic /Cond Dese.: CONDENSATE STORAGE TANK LEVEL Analog / Digital A Engr Units / Dig States: FEET Engr Units Conversion: N/A Minimum Instr Range: Maximum Instr Range: 25 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensore 1 Hov Processed: SIGNAL FROM LEVEL TRANSHITTER Sensor Location: LEVEL TX ON VATER COLUMUN IN RX BLDG Alarm / Trip Set Points: HI 24'(226.100 gal) LO-ll.5'(108,400 gal) HI Detector Power Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Mode LOV Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: Condensate Storage Tank (CST) Level B is the water level in the B CST. Two CSTs exist with a tank capacity of 230,000 gallons each. Makeup condensate water is provided through 3 electric pumps from the CST tanks to various plant systems. Each tank has suction line for Control Rod Drive, HPCI, Core Spray, RHR, and RCIC systems. At 7'(65,800 gal) receive CST Low-Lov Level alarm and condensate pumps trip. At 2'(18,800 gal) HPCI transfers to Torus suction. o.

i ' =,. f NSF NONTICELth NUCLRAR CENERATING PLANT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 44 of 60 DATA POINT LIBRARY REFERENCE FILE f Date: 01/07/92 4 Reactor Unit M01 l Data Feeder PCS NRC ERDS Parameter: VIND SPEED Point ID: HET102 i Plant Spec Point Desc.: PRIMARY MET TOVER 43h AVG.VIND SPEED A j Generic /Cond Desc.: VIND SPEED AT THE REACTOR SITE Analog / Digital -h Engr Units / Dig States: MPH Engr Unita Conversion: N/A Minimum Instr Range 0 Maximum Instr Range: 100.00 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors:- 1 Hov Processed:- 15 MINUTE AVERAGE OP $ SECOND VALUES Sensor Location: PRIMARY MET TOVER AT 43 METER HEIGHT-Alarm / Trip Set Points: N/A l NI Detector Power Supply N/A Cut-off Power Levels i NI Detector Pover-Supply N/A Turn-on Power Levels. Instrument Pailure Mode HIGH &'LOV SENSOR Temperature Compensation N/A-For DP Transmitters Level Reference Leg: N/A Unique System Desc.: Data is collected every five seconds, averaged-every 15 minutes, and stored ~in~ data files as 15-minute average. 1 i Ll l r -i 1 l J

NSF NONTICELIA NUCLRAR GENERATING PLANT RRDS-SRS-2iB EADS DAT/. POINT LIBRARY - Page 45 of 60 i DATA POINT LIBRARY REFERENCR FILE Date: 01/07/92 Reactor Unit M01 Data Feeder: PCS NRC ERDS Parameters-VIND SPEED Point ID: MET 103 Plant Spec Point Desc.: PRIMARY MET TOVER 43H AVG VIND SPEED B Generic /Cond Dese.: VIND SPEED AT THE REACTOR SITE Analog / Digital A Engr Units / Dig States: HPH Engr Units Conversion N/A Minimum Instr Range 0 Maximum Instr Range: 100.00 Zero Point Reference N/A-Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 1 How Processed: 15 MINUTE AVERAGE OF 5 SECOND VALUES i Sensor Locations-PRIMARY HET TOVER AT 43 HETER HEIGHT Alarm / Trip Set Points: N/A HI Detector Power Supply N/A Cut-off Power Level NI Detector Power Supply N/A l Turn-on Power Level: Instrument Failure Modes HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters:- Level Reference Leg N/A Unique System Desc.: Data is collected every five' seconds,; averaged every 15 minutes,:-and stored in data files as 15-minute average. t b J w p. T e er

NSP MONTICRLLO NUCLEAR CENERATING PLANT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Page 46 of 60 DATA POI!fP LIBPARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder: PCS NRC ERDS Parameter: VIND SPEED Point ID: HET104 Plant Spec Point Desc.: PRIMARY HET T0VER 100H AVG VIND SPEED A Generic /Cond Desc.: VIND SPEED AT THE REACTOR SITE Analog / Digital A Engr Units / Dig States: HPH Engr Units Conversion: N/A Minimum Instr Range 0 Maximum Instr Range 100.00 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 1 Hov Processed: 15 HINUTE AVERAGE OF 5 SECOND VALUES Sensor Location: PRIMARY HET T0VER AT 100 HETER HEIGHT Alarm / Trip Set Points: N/A HI Detector Power Supply N/A Cut-off Power Level: NI Detector Pover, pply N/A Turn-on Power Level Instrument Failure Mode HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg: N/A Unique System Desc.: Data is collected every five seconds, averaged every 15 minutes, and stored in data files as 15-minute average. I

NSF NOIrrICEl.14 NUCLEAR GWGOLATING PIRff ERDS-8RS-2. j ERDS DATA POINT LIBRARY Page 47 of 60 i DATA POINT LIBRARY REFERENCE FILE 4 Date: 01/07/92 Reactor Unita H01 Data Peeders PCS NRC ERDS Parameter: VIND SPEED Point ID: HET105 Plant Spec Point Desc.: PRIMARY HET T0VER 100H AVG VIND SPEED B.

l Generic /Cond Desc.:

VIND SPEED AT THE REACTOR SITE Analog / Digital A l Engr Units / Dig States HPil Engr Units Conversion N/A Minimum Instr Range: 0 Maximum Instr Range 100.00-Zero Point Reference N/A Reference Point Notes: N/A i PROC or SENS: P Number of Sensors: 1 How Processed: 15 MINUTE AVERAGE OP $ SECOND VALUES' Sensor Location: PRIMARY HET TOVER AT 100 METER HEIGHT: Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level NI Detector Power Supply N/A Turn-on Power Levelt Instrument Pailure Modes HIGli & LOW SENSOR. Temperature Compensation N/A Por DP Transmitters: Level Reference Leg N/A tinique System Desc.: Data is collected every five; seconds; averaged every 15 minutesi and-stored in - r data tiles as 15-minute average. i l

T i e NSF MONTICRLIA NUCLEAR GENERATING PIANT. BRDS-SRS-1-5

  • )

_ERDS DATA POINT LIBRARY Page 48 of 60-i DATA POINT LIBRARY REFERENCE FIIA i Date: 01/07/92 i Reactor Unit H01 Data Feeder: PCS NRC ERDS Parameter VIND DIR Point ID: NET 106 Plant Spec Point Desc.: -PRIMARY HET TOVER 43H AVG VIND DIRECT A Generic /Cond Desc.: -VIND DIRECTION AT THE REACTOR SITE. Analog / Digital A Engr _ Units / Dig States DEGPR 1 Engr Units conversion: N/A-Minimum Instr Range 0 Maximum -Instr Range: 540.00 t Zero Point

Reference:

N/A l Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 1 How Processed: 15 H NUTE AVERAGE OF $ SECOND VALUES Sensor Location: PRIMARY MET TOVER AT 43 HETER HEIGHT Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level: 1 ' [l NI-Detector Power Supply N/A Turn-on Power Level Instrument Failure Modes HIGH & LOV SENSOR Temperature Compensation N/A

i For DP Transmitters Level Reference Leg:

N/A ~ -{ Unique System Desc.: Data is collected every five seconds,-- averaged every 15 minutes, and~ stored in data-files as 15-minute average. t i sy e o n e..- y a nw-y +n,- -:-,,+ + -, -. ~ - ~ p ,ve~-

e i l 4-NSF NONTICELIA NUCLRAR GENERATING PLANT ERDS-SRS-2-5 EROS DATA POINT LIBRARY Page 49 of 60 DATA POINT LIBRARY REFERENCE PILE Date: 01/07/92 Reactor Unit M01 j Data Feeder PCS NRC ERDS Parameter VIND DIR i Point ID: HET107 Plant Spec Point Dese.: PRIMARY MET TOVER 43H AVG VIND DIRECT B Generic /Cond Dese.: VIND DIRECTION AT.THE REACTOR SITE 'i Analog / Digital A Engr Units / Dig States: DEGFR Engr Units Conversion: N/A Minimum Instr Range 0 Maximum Instr Range: 540.00 Zero Point Reference N/A Reference Point Notes: N/A PROC or SENS:- P i Number of Sensors: 1 How Processed: 15 MINUTE AVERAGE OF 5 SECOND. VALUES Sensor Location: PRIMARY MET TOVER AT 43 HETER HEIGHT i Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Levels NI Detector Pover-Supply N/A Turn-on Power Levels Instrument Failure Modes HIGH & LOV SENSOR-Temperature Compensation N/A J For DP Transmitters: Level Reference Leg N/A Unique System Desc. - Data is collected.every five seconds, averaged every 15 minutes. and stored in- ~i data files as 15-minute average.- d a ,{,- ..v..rt.3i. y n....m

.e NSF MONTICRLIA NUCl2AR GENERATING PLANT - ERDS-BRS-2-3 4 _ERDS DATA POINT LIBRARY Page 50 of 60~ DATA POINT LIBRARY REFERENCE TILE-Date: 01/07/92 Reactor Unit H01 Data Peeder PCS NRC ERDS Parameter VIND DIR Point ID: HET108-Plant Spec Point Dese.: PRIMARY MET TOVER 100H AVG VIND DIRECT A Generic /Cond Desc.: VIND DIRECTION AT THE REACTOR SITE Analog / Digital A Engr Units / Dig States: DEGFR Engr Units Conversion: N/A Minimum Instr Range 0 Maximum Instr Rangen-540.00 u Zero Point References.. N/A I Reference Point !!otest N/A PROC or SENS: P Number of Sensors: 1 How Processed ~ 15 MINUTE AVERAGE OF 5 SECOND VALUES Sensor Location: PRIMARY HIT TOWER AT 100 METER HEIGHT 's Alarm / Trip Set Points: N/A HI Detector Power Supply N/A Cut-off Pover Levels-NI-Detector Power Supply N/A Turn-on Power Levels Instrument Failure Modes HIGH & u0V SENSOR Temperature Compensation- ,N/A Por DP-Transmitters - Level Reference Legs-N/A: Unique System Desc.: Data is collected every five seconds, s averaged every 15 minutes, and stored in -data-files as 15-minute average.-

L,' NSP HONTICELth NUCLEAR GENFRATING PLAl(T KRDS-SRS-2-B ERDS DATA POINT LIBRARY Page 51 of 60 DATA P0lfff LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Cait: H01 Data Feeder PCS NRC ERDS Parameter VIND DIR Point ID: HET109 Plant Spec Point Dese.: PRIMARY HET TOVER 100H AVG VIND DIP.ECT B Generic /Cond Desc.: VIND DIRECTION AT Tile REACTOR SITE Analog / Digital A Engr Units / Dig States: DEGPR Engr Unito Conversions N/A Minimum Instr Range 0 Haximum Instr Range: 540.00 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 1 llov Processed: 15 HINUTE AVERAGE OF 5 SECOND VALUES Sensor Location: PRIMARY MET TOVER AT 100 HETER !!EIGilT Alarm / Trip Set Points: N/A HI Detector Power Supply N/A cut-off Power Level NI Detector Power Supply N/A Turn-on Power Levels Instrument Failure Mode !!IGil & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: Data is collected every five seconds, averaged every 15 minutes, and stored in data files as 15-minute average. l _w

~ t NSF N00fflCEL14 NUC12AR GENERATING PLANT ERDS-SRS-2-5 ' e i ERDS DATA POIlff LIBRARY Page 52 of 60 i DATA POINT LIBRARY-REFERENCE FI12 Dates-01/07/92 Reactor Unit M01 Data Feeder: PCS NRC ERDS Parameter STAB CLASS l PointID: MET 110 Plant Spec Point Dese. PRIMARY MET 70VER 43M AVG' DELTA TEMP A Generic /Cond Desc.: AIR STABILITY-AT THE REACTOR SITE Analog / Digital A Engr Units / Dig States DEGF j Engr Units Conversion: N/A l Minimum Instr Range --9.0 Maximum Instr Range 9.0 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors 2 Hov. Processed: AVERAGED DIFFERENTIAL. Sensor Location: PRIMARY MET AT-10'& 43 HETER HEIGHT Alarm / Trip Set Points: N/A NI Detector Power Supply .N/A Cut-off Power. Levels 1 NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Mode HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Dese.: Data is collected every five seconds, averaged every 15 minutes,:and. stored:in data files as.15-minute average. This. value' represents the difference 11n 1 temperature in degF/100ft.- i ( 't .;I ' I h -f, +, a, ,..w,~.yL.,., v. ,,,~,.,m. y-.r.. c.',--, 2 ^,s , a 4

a. NSP MONTICELLO NUCLEAR GENERATING PLANT KRDS-SRS-2-B ERDS DATA POINT IJBRARY Page 53 of 60 DATA POI!ff LIBRARY REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feedert PCS NRC ERDS Parameter STAB CLASS PointID: HET111 Plant Spec Point Desc.: PRIMARY MET TOVER 43M AVG DELTA TEMP B Generic /Cond Desc.: AIR STABILITY AT THE REACTOR SITE Analog / Digital A Engr Units / Dig States DEGP Engr Units Conversion: N/A Minimum Instr Range -9.0 Haximum Instr Range 9.0 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: PROC Number of Sensors 2 Ilov Processed: AVERAGED DIFFERENTIAL Sensor Location PRIMARY HET AT 10 & 43 HETER IIEIGilT Alarm / Trip Set Points: N/A NI Detector Power Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Level Instrument Failure Modes llIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg: N/A Unique System Dese.: Data is collected every five seconds, averaged every 15 minutes, and stored in data files as 15-minute average. This value represents the difference in temperature in degF/100ft.

l r-C5P MONTICRLLO NUCLEAR GENERATING P! ANT ERDS-bRS-2-5 ERDS DATA POINT LIBRARY Page_54 of 60 DATA POINT LIBRARY REFERENCE FILE Date: 01/07/92 l Reactor Unit: M01 l Data Feeder PCS NRC ERDS Parameter STAB CLASS 1 PointID: NET 112-Plant Spec Point Dese.: PRIMARY MET T0VER 100M AVG DELTA TEMP _A Generic /Cond Desc.: AIR STABILITY AT THE REACTOR SITE Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A L Minimum Instr Range -9.0 Maximum Instr Range 9.0 Zero Point Reference N/A Reference Point Notes: N/A PROC or FENS: PROC Number of Sensors: 2 Hov Processed: AVERAGED DIFFERENTIAL Sensor Location: PRIMARY MET AT 10 & 100 METER HEIGHT J Alarm / Trip Set Points: N/A i NI Detector Pover Supply N/A Cut-off Power Level NI Detector _ Power Supply N/A Turn-on Power Levels Instrument Failure Modes HIGH & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: Data is collected every five_ seconds, averaged every 15 minutes, :and stored in data files as 15-minute average. This' value represents the difference in temperature in degF/100ft. e s --r, = - =a-- - - -. -, w ,, +,, r 3 , h y- ., ww y r, ,y-

o NSP H0fff1 CELLO NUCLEAR GENERATING PLANT ERDS-SRS-2-B ERDS DATA POINT LIBRARY Pag,e 55 of 60 DATA POIfff LIBRA %7 REFERENCE FILE Date: 01/07/92 Reactor Unit H01 Data Feeder: PCS NRC ERDS Paremoters STAB CLASS PointID: HET113 Plant Spec Point Desc.: PRIMARY HET TOVER 100H AVG DELTA TEMP B Generic /Cond Dest.: AIR STABILITY AT THE REACTOR SITE Analog / Digital: A Engr Units / Dig States: DEGF Engr Units Conversion: N/A Minimum Instr Range -9.0 Haximum Instr Range 9.0 Zero Point References N/A Reference Point Notes: N/A PROC or SENS: PROC Humber of Sensorcs 2 How Processed: AVERAGED DIFFERENTIAL Sensor Location: PRIMARY MET AT 10 & 100 METER HEIGHT Alarm / Trip Set Peints: N/A NI Detector Power Supply N/A Cut-off Power Level: NI Detector Power Supply N/A Turn-on Power Levcl Instrument Failure Moder llIGil & LOV SENSOR Temperature Compensation N/A For DP Transmitters: Level Reference Leg N/A Unique System Desc.: Data is collected every five seconds, averaged every 15 minutes, and stored in data files as 15-minute average. This value represents the difference in temperature in degF/100ft.

o e NSP MONTICELLO NUCLEAR CENERATING PLANT RRDS-SRS-2-B e ERDS DATA POINT LIBRARY Page 56 of 60

1. Contacts Note: Please provide name, title, mailing address and phone number.

[~ A. Survey Coordinator (i.e. contact for later clarification of questionnaire ansvers): Russell E. Van Dell Superintendent, Computer Services Northern States Power company Monticello Nuclear Generating Plant 2807 V. Highway 75 Honticello, MN 55362 (612) 295-1326 B. Computer Hardware Specialist (s): Joe Jirsa Engineer Associate III Northern States Power Company Monticello Nuclear. Generating Plant 2007 V. Highway 75 Honticello, MN 55362 (612) 295-1388 C. Systems 5-ftware Specialist (s): Joe Sofge Sr. Comp. Engr. Northern States Power Company Monticello Nuclear Generating Plant 2807 V. Highway 75 Honticello, MN 55362 (612) 295-1289 D. Application-level-Software Specialist (s): Joe Sofge Sr. Comp. Engr. Northern States Power Company Monticello Nuclear Generating Plant 2807 V. Highway 75 Honticello, MN 55362 (612) 295-1289 E. Telephone Systems Specialist (s): David Seestrom Instrument Engineer Northern States Power Company Monticello Nuclear Generating Plant 2807 V. Highway 75 Honticello, MN - 55362 _(612)-295-1376 v

a NSP MONTICELIA NUCLEAR GENERATING PLANT ERDS-SRS-2-5 ERDS DATA POINT LIBRARY Page 57 of 60 III. Selection of Data Feeders A. Ilov many data feeders are there (six maximum)? One - Process Computer System B. Identify the selected data feeders and provide the following for eacht (1) a short description of the categories of data points it vill provide (e.g., met, rad, or plant data points, by unit) and (2) the rationale for selecting it if another system can also provide its categories of data points. (1) It is planned to provide both plant data points and peteorological information through the single feeder. (2) N9 other system is capable of providing requested information. C. Which data feeder is the site time determining feeder? This should be the feeder which is providing the majority of the data points.

.. o MSP MONTICELLO NUCLRAR GENERATING PiAfT ERDS-SRS-2-3 _ RADS DATA POINT' LIBRARY Page 58 oi 60' { ' l IV. Data--Feeder Information~ i Note A new Section IV aust be filled-out for each feeder system selected. General Questions ? 1. Identification of Data Feeder a. Vhat is the name in local parlance given to this_ data feeder (e.g., Emergency Response _Information System)? Please give.both the acronym and the words forming it. PCS - Process Computer System b. Is this the site time determining feeder? Yes c. How often vill this feeder transmit an update set.to the ERDS (in seconds)? 60 Seconds 2. Hardware / Software Environment b a. Identify the manufacturer and model number of the data feeder hardware. Digital Equipment Corporation VAX-8550 b. Identify the operating system. VAX VMS 4.7 c. _Vhat method of' timekeeping is implemented on this-feeder system (Daylight Gavings,_ Standard, Greenwich)?

  • =

Daylight Savings d. In-what time zone is'this feeder located 7-i Central Standard Time Zone-o l 'S ,--vr ,.s.rr' w e-- 7+ e---* r e'"f

    • t
  • r-v-t-

e T" T

10 ~ NSF MONYICELth NUCt. EAR GWfERATING PLANT - IRDS-SRS-2-5 ERDS DATA POINT LIBRARY Pase 59 of 60 3. Data Communication Details a. Can this data feeder provide asynchronous serial data-communication (RS-232-C) with full-modem contro17 Yes b. Vill this feeder transmit in ASCII or EBCDIC 7 ASCII c. Can this feeder transmit at a serial baud rate of 2400 bps? If not, at what baud rate can it transmit? Yes, 2400 bps can be.used. d. Does the operating system support XON/XOFF flow control? Yes 1. Are any problems foreseen with the NRC using XON/X0FF to. control the: transmission of data?- No,.however the use of SUSPEND ~and RESUME to control:the ~ transmission of data vorks better as demonstrated in testing with Haliburton/NUS. e. If it is not feasibl. to recontigure a serial port for the ERDS-. linkup (i.e., change the baud rate, parity, etc.), nicase explain why. ~ Note Applicable. f. Do any ports currently exist for the ERDS' linkup?' Yes. 1. If not, is it possible to add additional ports?. _ Not Applicable.- _L L 4 ...n,.,

1: s '<4-c o. -3g_ MSP NONTICRLLO NUCLEAR GENERATING PLANT - ERDS-SRS-2 *-

  • ERDS DATA POINT LIBRARY

' Page 60 of 60 2. If; yes,= vill-the port fbe used solelyLby the ERDS or shared vith other non-emergency-time users?L_Givezdetails.: Port vill be dedicated-for ERDS. ~ 4. Data Feeder Physical' Environment and Management Where is the data: feeder located in terms of the TSC,= EOF,land a. control room? P Computer Room located'in-Plant Administrative Building: adjacent tot Plant Control Room, b. Is the data feeder protected from loss of supply of electricity?L Yes, PCS is provided with UPS (batteries with inverter and-diesel generator). 4. c. Is there a human operator.for this data-feeder?- t Yes 1. If so, how many hours a day is the feeder attended?- It-is planned to have the Shift Emergency Communicator _(SEC) initiate the'ERDS System per Emergency Implementing Procedures.- An SEC is on duty ~24 hours / day.. y a i N i Y W y-' q ,~ s ~, 4 e>~- .~ n v v}}