MONTHYEARML20217M3371999-10-20020 October 1999 Forwards Notice of Docketing of License SNM-2506 Amend Application.Notice Has Been Forwarded to Ofc of Fr for Publication ML20217M1111999-10-19019 October 1999 Forwards Insp Repts 50-282/99-14 & 50-306/99-14 on 990920- 22.One Violation Noted & Being Treated as Ncv.Insp Focused on Testing & Maint of Heat Exchangers in High Risk Sys ML20217F4331999-10-15015 October 1999 Forwards Rev 39 to Security Plan.Changes Do Not Decrease Effectiveness of Security Plan.Rev Withheld,Per 10CFR73.21 ML20217C2351999-10-0606 October 1999 Forwards Insp Repts 50-282/99-12 & 50-306/99-12 on 990823-0917.No Violations Noted.Insp Consisted of Selected Exam of Procedures & Representative Records,Observation of Activities & Interviews with Personnel ML20212J8811999-09-28028 September 1999 Forwards Preliminary Accident Sequence Precurson Analysis of Operational Event That Occurred at Plant,Unit 1 on 990105, for Review & Comment.Comment Requested within 30 Days of Receipt of Ltr IR 05000272/19990071999-09-28028 September 1999 Forwards Insp Repts 50-272/99-07 & 50-306/99-07 on 990721- 0831.One Potentially Safety Significant Issue Identified Dealing with Control Room Special Ventilation System.Four Addl Issues of Low Safety Significance Identified ML20212G7171999-09-24024 September 1999 Submits Semiannual Status Update on Project Plans for USAR Review Project & Conversion to Its.Conversion Package Submittal Continues to Be Targeted for Aug of 2000 ML20212G9801999-09-23023 September 1999 Refers to Resolution of Unresolved Items Identified Re Security Alarm Station Operations at Both Monitcello & Prairie Island ML20212F5121999-09-20020 September 1999 Forwards Response to NRC , Preparation & Scheduling of Operator Licensing Examinations ML20212D8401999-09-16016 September 1999 Discusses 990902 Telcon Between D Wesphal & R Bailey Re Administeration of Retake Exam at Prairie Island During Wk of 991206.NRC May Make Exam Validation Visit to Facility During Wk of 991116 ML20217H2331999-09-10010 September 1999 Forwards Security Insp Repts 50-282/99-10 & 50-306/99-10 on 990809-12.Two Findings,Each of Low Risk Significance Identified & Being Treated as non-cited Violations Consistent with App C of Enforcement Policy ML20217H5661999-09-0909 September 1999 Discusses 990907 Pilot Plan Mgt Meeting Re Results to-date of Pilot Implementation of NRC Revised Reactor Oversight Process at Prairie Island & Quad Cities.Agenda & Handouts Provided by Utils Encl ML20212A9241999-09-0909 September 1999 Discusses Plans Made During 990902 Telephone Conversation to Inspect Licensed Operator Requalification Program at Prairie Island During Weeks of 991101 & 991108.Requests That Written Exams & Operating Tests Be Submitted by 991022 ML20212B0511999-09-0909 September 1999 Forwards Insp Repts 50-282/99-11 & 50-306/99-11 on 990816-20.One Issue of Low Safety Significance Was Identified & Being Treated as Ncb ML20211Q7641999-09-0808 September 1999 Informs That NRC Tentatively Scheduled Initial Licensing Exam for Plant Operator License Applicants During Wk of 000515,in Response to D Westphal ML20211N8631999-09-0707 September 1999 Withdraws 970814 Request for Exemption from 10CFR50,App R, Section III.G.2, Fire Protection of Safe Shutdown Capabilities ML20211K5911999-09-0101 September 1999 Informs That Util Reviewed Rvid Data Base,As Requested in NRC .Summary of Proposed Changes & Observed Differences Are Included in Encl Tables ML20211L0211999-09-0101 September 1999 Provides Notification That License Amends 141 & 132 & Associated License Conditions 6 & 7 Have Been Fully Implemented ML20211K5931999-08-31031 August 1999 Forwards License Amend Request for License SNM-2506, Proposing Change to License Conditions 6,7 & 8 & TSs App a of License by Permitting Inclusion of Bpras & Thimble Plug Devices in Sf Assemblies Stored in TN-40 Casks ML20211Q6041999-08-31031 August 1999 Forwards Rev 19 to USAR for Pingp,Per 10CFR50.71(e).Rev Brings USAR up-to-date as of 990228,though Some Info Is More Recent.Attachment 1 Contains Descriptions & Summaries of SE for Changes,Tests & Experiments,Per 10CFR50.59 ML20211K2591999-08-27027 August 1999 Forwards NSP Co Fitness for Duty Program Performance Data for Six Month Period Ending 990630 ML20211D3541999-08-24024 August 1999 Discusses GL 95-07 Re Pressure Locking & Thermal Binding of safety-related Power Operated Gate Valves.Forwards SE Re Response to GL 95-07 ML20211C7601999-08-19019 August 1999 Confirms NRC Intent to Meet with NSP & Ceco on 990807 in Lisle,Il to Discuss with Region III Pilot Plants,Any Observations,Feedback,Lessons Learned & Recommendations Relative to Implementation of Pilot Program ML20211B8311999-08-19019 August 1999 Forwards Request for Relief 8 Re Limited Exams Associated with Unit 1 Third ten-year Interval Inservice Insp Program. Licensee Requests Relief Due to Impractibility of Obtaining 100% Exam Coverage for Affected Items ML20211B5711999-08-19019 August 1999 Forwards Second 90-day Rept for Implementation of Voltage Based Repair Criteria at Prairie Island Unit 1.Rept Fulfills Requirements of Section 6.b of Attachment 1 to GL 95-05 ML20211C2311999-08-19019 August 1999 Forwards Unit 1 ISI Summary Rept,Interval 3,Period 2 Refueling Outage Dates 990425-0526,Cycle 19 971212-990526. Rept Identifies Components Examined,Exam Methods Used,Exam Number & Summarizes Results ML20211B0561999-08-18018 August 1999 Provides Addl Info on Proposed Rev to Main Steam Line Break Methodology ,in Response to NRC Staff Request Made in 990416 Telcon.Nuclear Svcs Corp Rept PIO-01-06, Analysis Rept Structural Analyses of Main Steam Check... Encl ML20211B2621999-08-17017 August 1999 Forwards Insp Repts 50-282/99-09 & 50-306/99-09 on 990719-22.No Violations Noted.Insp Included Review & Evaluation of Current Emergency Preparedness Performance Indicators ML20211C7371999-08-17017 August 1999 Discusses Closure of Staff Review Re Generic Implication of Part Length Control Rod Drive Mechanism Housing Leak on 980123.Enclosed NRC 980811 & 1223 Ltrs Responded to WOG Positions Re Corrective Actions ML20210T5661999-08-12012 August 1999 Forwards RAI Re & Suppl ,which Requested Exemptions from TSs of Section III.G.2 of 10CFR50 App R,To Extent That Specifies Separation of Certain Redundant Safe Shutdown Circuits with fire-related Barriers ML20210R7021999-08-12012 August 1999 Forwards Insp Repts 50-282/99-06 & 50-306/99-06 on 990601- 0720.One NCV Occurred,Consistent with App C of Enforcement Policy ML20210P5191999-08-11011 August 1999 Discusses GL 92-01,Rev 1,Supp 1, Rv Integrity, Issued by NRC on 950519 & NSP Responses for PINGP & 951117. Staff Reviewed Info in Rvid & Released Info as Rvid Version 2.Requests Submittal of Comments Re Revised Rvid by 990901 ML20210G5061999-07-30030 July 1999 Responds to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates 05000282/LER-1999-007, Forwards LER 99-007-00,re Loss of CR Special Ventilation Function.One New Commitment Was Made in Rept as Indicated in Corrective Action Section Statement in Bold Italics1999-07-23023 July 1999 Forwards LER 99-007-00,re Loss of CR Special Ventilation Function.One New Commitment Was Made in Rept as Indicated in Corrective Action Section Statement in Bold Italics ML20210J4991999-07-22022 July 1999 Forwards Rev 18 to USAR for Pingp,Bringing USAR up-to-date as of 990228,though Some Info More Recent.Safety Evaluation Summaries Also Encl ML20209J0941999-07-15015 July 1999 Forwards SER Finding Rev 7 to Topical Rept NSPNAD-8102, Reload Safety Evaluation Methods for Application to PI Units, Acceptable for Ref in Plant Licensing Actions ML20209H8051999-07-14014 July 1999 Forwards Summary of non-modification Safety Evaluation Number 515 Re Storage of Fuel Inserts,Per Insp Rept 72-0010/99-201 ML20209D4181999-07-0707 July 1999 Informs That Util Has Changed Listed TS Bases Pages Attached for NRC Use.Util Made No New Commitments in Ltr ML20209H8361999-07-0202 July 1999 Forwards Operator Licensing Exam Repts 50-282/99-301(OL) & 50-306/99-301(OL) for Tests Administered During Week of 990517-21.Two Applicants Passed All Sections of Exam & Issued Reactor Operator Licenses to Operate Pings ML20196J9681999-07-0101 July 1999 Informs That in Sept 1998,Region III Received Rev 20 to Portions of Util Emergency Plan Under 10CFR50.54(q).Based on Determination That Changes Do Not Decrease Effectiveness of Licensee Emergency Plan,No NRC Approval Required ML20209C3951999-07-0101 July 1999 Forwards Supplemental Response to GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves ML20209B7541999-07-0101 July 1999 Final Response to GL 98-01,Suppl 1 Re Y2K Readiness of Computer Sys.Sys Remediated as Required for Plant Operation. Contingency Plans Developed to Mitigate Impact of Y2K-induced Events at Key Rollover Dates ML20196J8941999-06-30030 June 1999 Transmits Util Comments on Draft Regulatory Guide DG-1074, Steam Generator Tube Integrity. Licensee Recommends That NRC Focus on Several Important Listed Areas Considered Principal Concerns & Contentions ML20209F0391999-06-30030 June 1999 Forwards Insp Repts 50-282/99-04 & 50-306/99-04 on 990407-0531.Violation Noted.Notice of Violation or Civil Penalty Will Not Be Issued,Based on NRC Listed Decision to Exercise Discretion ML20209C3011999-06-29029 June 1999 Forwards Annual Rept of Corrections to NSP ECCS Evaluation Models,Iaw 10CFR50.46.Since All Analyses Remain in Compliance,No Reanalysis Is Required or Planned ML20209B5751999-06-24024 June 1999 Submits Revised Relief Request for Limited Examinations Associated with Third 10-yr ISI Examination Plan.Attached Is Unit 1 Relief Request 7,rev 1 Which Addresses Limited Examinations ML20196F3871999-06-23023 June 1999 Forwards Revised Pages 71,72 & 298 of Rev 7 to NSPNAD-8102, Prairie Island Nuclear Power Plant Reload Safety Evaluation Methods for Application to PI Units, Per Discussions with Nrc.Approved Version of Rept Will Be Issued 05000282/LER-1999-006, Forwards LER 99-006-00 Re Discovery That Manual SI Actuation Switch Had Not Been Tested on Staggered Basis During Integrated SI Test.Two New Commitments Are Indicated in Corrective Action Section Statement in Bold Italics1999-06-18018 June 1999 Forwards LER 99-006-00 Re Discovery That Manual SI Actuation Switch Had Not Been Tested on Staggered Basis During Integrated SI Test.Two New Commitments Are Indicated in Corrective Action Section Statement in Bold Italics ML20196D5501999-06-18018 June 1999 Forwards Individual Exam Results for Licensee Applicants Who Took May 1999 Initial License Exam.In Accordance with 10CFR2.790,info Considered, Proprietary. Without Encls ML20196A6741999-06-17017 June 1999 Refers to 990517-20 Meeting with Util in Welch,Minnesota Re Licensee Initiatives in Risk Area & to Establish Dialog Between SRAs & Licensee PRA Staff 1999-09-09
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML20217F4331999-10-15015 October 1999 Forwards Rev 39 to Security Plan.Changes Do Not Decrease Effectiveness of Security Plan.Rev Withheld,Per 10CFR73.21 ML20212G7171999-09-24024 September 1999 Submits Semiannual Status Update on Project Plans for USAR Review Project & Conversion to Its.Conversion Package Submittal Continues to Be Targeted for Aug of 2000 ML20212F5121999-09-20020 September 1999 Forwards Response to NRC , Preparation & Scheduling of Operator Licensing Examinations ML20211N8631999-09-0707 September 1999 Withdraws 970814 Request for Exemption from 10CFR50,App R, Section III.G.2, Fire Protection of Safe Shutdown Capabilities ML20211K5911999-09-0101 September 1999 Informs That Util Reviewed Rvid Data Base,As Requested in NRC .Summary of Proposed Changes & Observed Differences Are Included in Encl Tables ML20211L0211999-09-0101 September 1999 Provides Notification That License Amends 141 & 132 & Associated License Conditions 6 & 7 Have Been Fully Implemented ML20211Q6041999-08-31031 August 1999 Forwards Rev 19 to USAR for Pingp,Per 10CFR50.71(e).Rev Brings USAR up-to-date as of 990228,though Some Info Is More Recent.Attachment 1 Contains Descriptions & Summaries of SE for Changes,Tests & Experiments,Per 10CFR50.59 ML20211K5931999-08-31031 August 1999 Forwards License Amend Request for License SNM-2506, Proposing Change to License Conditions 6,7 & 8 & TSs App a of License by Permitting Inclusion of Bpras & Thimble Plug Devices in Sf Assemblies Stored in TN-40 Casks ML20211K2591999-08-27027 August 1999 Forwards NSP Co Fitness for Duty Program Performance Data for Six Month Period Ending 990630 ML20211C2311999-08-19019 August 1999 Forwards Unit 1 ISI Summary Rept,Interval 3,Period 2 Refueling Outage Dates 990425-0526,Cycle 19 971212-990526. Rept Identifies Components Examined,Exam Methods Used,Exam Number & Summarizes Results ML20211B8311999-08-19019 August 1999 Forwards Request for Relief 8 Re Limited Exams Associated with Unit 1 Third ten-year Interval Inservice Insp Program. Licensee Requests Relief Due to Impractibility of Obtaining 100% Exam Coverage for Affected Items ML20211B5711999-08-19019 August 1999 Forwards Second 90-day Rept for Implementation of Voltage Based Repair Criteria at Prairie Island Unit 1.Rept Fulfills Requirements of Section 6.b of Attachment 1 to GL 95-05 ML20211B0561999-08-18018 August 1999 Provides Addl Info on Proposed Rev to Main Steam Line Break Methodology ,in Response to NRC Staff Request Made in 990416 Telcon.Nuclear Svcs Corp Rept PIO-01-06, Analysis Rept Structural Analyses of Main Steam Check... Encl ML20210G5061999-07-30030 July 1999 Responds to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates 05000282/LER-1999-007, Forwards LER 99-007-00,re Loss of CR Special Ventilation Function.One New Commitment Was Made in Rept as Indicated in Corrective Action Section Statement in Bold Italics1999-07-23023 July 1999 Forwards LER 99-007-00,re Loss of CR Special Ventilation Function.One New Commitment Was Made in Rept as Indicated in Corrective Action Section Statement in Bold Italics ML20210J4991999-07-22022 July 1999 Forwards Rev 18 to USAR for Pingp,Bringing USAR up-to-date as of 990228,though Some Info More Recent.Safety Evaluation Summaries Also Encl ML20209H8051999-07-14014 July 1999 Forwards Summary of non-modification Safety Evaluation Number 515 Re Storage of Fuel Inserts,Per Insp Rept 72-0010/99-201 ML20209D4181999-07-0707 July 1999 Informs That Util Has Changed Listed TS Bases Pages Attached for NRC Use.Util Made No New Commitments in Ltr ML20209C3951999-07-0101 July 1999 Forwards Supplemental Response to GL 95-07, Pressure Locking & Thermal Binding of SR Power-Operated Gate Valves ML20209B7541999-07-0101 July 1999 Final Response to GL 98-01,Suppl 1 Re Y2K Readiness of Computer Sys.Sys Remediated as Required for Plant Operation. Contingency Plans Developed to Mitigate Impact of Y2K-induced Events at Key Rollover Dates ML20196J8941999-06-30030 June 1999 Transmits Util Comments on Draft Regulatory Guide DG-1074, Steam Generator Tube Integrity. Licensee Recommends That NRC Focus on Several Important Listed Areas Considered Principal Concerns & Contentions ML20209C3011999-06-29029 June 1999 Forwards Annual Rept of Corrections to NSP ECCS Evaluation Models,Iaw 10CFR50.46.Since All Analyses Remain in Compliance,No Reanalysis Is Required or Planned ML20209B5751999-06-24024 June 1999 Submits Revised Relief Request for Limited Examinations Associated with Third 10-yr ISI Examination Plan.Attached Is Unit 1 Relief Request 7,rev 1 Which Addresses Limited Examinations ML20196F3871999-06-23023 June 1999 Forwards Revised Pages 71,72 & 298 of Rev 7 to NSPNAD-8102, Prairie Island Nuclear Power Plant Reload Safety Evaluation Methods for Application to PI Units, Per Discussions with Nrc.Approved Version of Rept Will Be Issued 05000282/LER-1999-006, Forwards LER 99-006-00 Re Discovery That Manual SI Actuation Switch Had Not Been Tested on Staggered Basis During Integrated SI Test.Two New Commitments Are Indicated in Corrective Action Section Statement in Bold Italics1999-06-18018 June 1999 Forwards LER 99-006-00 Re Discovery That Manual SI Actuation Switch Had Not Been Tested on Staggered Basis During Integrated SI Test.Two New Commitments Are Indicated in Corrective Action Section Statement in Bold Italics ML20195G4281999-06-0909 June 1999 Notifies That Amsac/Dss Mods Completed & TS 138/129 Has Been Fully Implemented 05000282/LER-1999-005, Forwards LER 99-005-00 Re Containment Inservice Purge Sys Not Isolated During Heavy Load Movement Over Fuel.Event Has Indicated That Level of Performance Expected by Mgt Has Not Yet Been Achieved1999-06-0707 June 1999 Forwards LER 99-005-00 Re Containment Inservice Purge Sys Not Isolated During Heavy Load Movement Over Fuel.Event Has Indicated That Level of Performance Expected by Mgt Has Not Yet Been Achieved ML20207F4301999-06-0101 June 1999 Forwards 1999 Unit 1 SG Insp Results,Per TS 4.12.E.1. Following Insp 84 Tubes Were Plugged for First Time ML20196L2461999-05-21021 May 1999 Forwards Rev 0 to COLR for Pingp,Unit 1 Cycle 20, IAW TS Section 6.7.A.6 ML20195C6861999-05-21021 May 1999 Forwards Rev 17 to USAR for Prairie Island Nuclear Generating Plant.Attachment 1 Contains Descriptions & Summaries of SEs for Changes,Tests & Experiments Made Under Provisions of 10CFR50.59 During Period Since Last Update ML20206U6781999-05-17017 May 1999 Forwards Revised Emergency Response Plan Implementing Procedures,Including Rev 15 to F3-3,rev 15 to F3-16,rev 14 to F3-22 & Table of Contents ML20206U7131999-05-17017 May 1999 Forwards Revised EOF Emergency Plan Implementing Procedures, Including Table of Contents & Rev 2 to F8-10, Record Keeping in Eof. with Updating Instructions ML20206T2461999-05-17017 May 1999 Forwards Off-Site Radiation Dose Assessment for Jan-Dec 1998, Rev 0 to Annual Radiactive Effluent Rept for 980105- 990103 & Effluent & Waste Disposal Annual Rept Solid Waste & Irradiated Fuel Shipments,Jan-Dec 1998 ML20206R0401999-05-13013 May 1999 Forwards Application for Amends to Licenses DPR-42 & DPR-60, Removing Plant Organization Requirement,Imposed in Amend 141/132 That Plant Manager,Who Has Responsibility for Overall Safe Operation of Plant,Report to Corporate Officer ML20206Q0871999-05-13013 May 1999 Forwards Result of Evaluation Re Ultrasonic Exams of SG Number 22 Performed in Accordance with ASME Boiler & Pressure Vessel Code Section Xi.Procedure Used for Evaluation Contained in WCAP-14166,submitted for Review ML20206F9381999-05-0303 May 1999 Forwards Response to NRC 990304 RAI Re GL 96-05 Program at Pingp.Licensee Commitments Are Identified in Encl as Statements in Italics ML20206J3851999-05-0303 May 1999 Forwards 1998 Annual Radiological Environmental Monitoring Rept 05000282/LER-1999-004, Forwards LER 99-004-00 Re Discovery of Inadequate Sp That Demonstrates Operability of SFP Special Ventilation Sys.Two New NRC Commitments Are Contained in Corrective Action Section of Rept in Bold Italics1999-05-0303 May 1999 Forwards LER 99-004-00 Re Discovery of Inadequate Sp That Demonstrates Operability of SFP Special Ventilation Sys.Two New NRC Commitments Are Contained in Corrective Action Section of Rept in Bold Italics ML20206E1761999-04-28028 April 1999 Forwards Revised TS Pages for Amends 144 & 135 to Licenses DPR-42 & DPR-60,respectively,to Update Controlled Manual or File ML20205S3221999-04-20020 April 1999 Forwards Application for Amends to Licenses DPR-42 & DPR-60, Changing Implementation Date for Relocation from TS to UFSAR of Requirements in TS 3.1.E & Flooding Shutdown Requirements of TS 5.1 ML20205P9891999-04-12012 April 1999 Requests Approval for Proposed Alternatives to Liquid Penetrant Requirements of N-518.4 of 1968 ASME Boiler & Pressure Vessel Code.Results of Analysis & Summary of Tests Performed & Tests Results Are Encl ML20205Q0191999-04-12012 April 1999 Forwards Application for Amend to License DPR-42 & DPR-60, Relocating Shutdown Margin Requirements from TS to COLR 05000282/LER-1998-010, Forwards LER 98-010-01 Re Discovery That 32 App R Related MOVs Are Susceptible to Physical Damage by Fire Induced Hot Shorts.Rept Provides Addl Details on Current Plans for Completing C/As Committed to in Original LER1999-04-0808 April 1999 Forwards LER 98-010-01 Re Discovery That 32 App R Related MOVs Are Susceptible to Physical Damage by Fire Induced Hot Shorts.Rept Provides Addl Details on Current Plans for Completing C/As Committed to in Original LER ML20205P9221999-04-0101 April 1999 Submits Relief Request 8,rev 0 Which Addresses Limited Exams Associated with Unit 2 Third ten-year Interval Inservice Insp Program.Util Requests Relief Per 10CFR50.55a(q)(5)(iii) Due to Impracticality of Obtaining 100% Exam Coverage ML20205E8371999-03-31031 March 1999 Submits Four Copies of Rev 38 to Prairie Island Security Plan,Per 10CFR50.54(p).Changes Do Not Decrease Effectiveness of Security Plan.Encl Withheld,Per 10CFR73.21 ML20196K7831999-03-31031 March 1999 Forwards Decommissioning Funding Status Rept for Monticello & Prairie Island Nuclear Generating Plants,Per Requirements of 10CFR50.75(f)(1) ML20205Q5051999-03-30030 March 1999 Forwards Inservice Insp Summary Rept Interval 3,Period 1 & 2 Refueling Outage Dates 981109-1229 Cycle 19,970327- 981229. Rept Identifies Components Examined,Exam Methods Used,Exam Number & Summarized Results ML20205H5731999-03-29029 March 1999 Submits Required 1998 Actual & 1999 Projected Cash Flow Statements for Monticello Nuclear Generating Plant & PINGP, Units 1 & 2.Encl Contains Proprietary Info.Proprietary Info Withheld,Per 10CFR2.790(b)(1) ML20205C6561999-03-26026 March 1999 Submits Semiannual Update on Project Plans for USAR Review Project & Conversion to ITS ML20204H3371999-03-19019 March 1999 Forwards Application for Amend to Licenses DPR-42 & DPR-60, Removing Dates of Two NRC SERs & Correcting Date of One SER Listed in Section 2.C.4, Fire Protection 1999-09-07
[Table view] |
Text
,
Northern States Power Company Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East Welch. Minnesota 35089 February 12,1996 Generic Letter 95-07 U S Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-60 Response to Generic Letter 95-07: Pressure Locking and Thermal Bindina of Safetv-Related Power-Ocerated Gate Valves The purpose of this letter is to provide the 180 day response required by NRC Generic Letter 95-07 for the Prairie Island Nuclear Generating Plant.
Generic Letter 95-07 (dated August 17,1995) was issued by the NRC requesting ;
licensees to provide information concerning (1) the evaluation of operational !
configurations of safety-related, power-operated gate valves for susceptibility to pressure locking and thermal binding; and (2) analyses, and needed corrective actions, to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing the required safety function, Generic Letter 95-07 contained the following required response:
Within 180 days from the date of this generic' letter, each addressee of this ]
generic letter is requested to implement and complete the guidance provided in Attachment 1 to perform the following actions:
1
- 1. Evaluate the operational configurations of safety-related power-operated j (i.e., motor-operated, air-operated, and hydraulically operated) gate l valves in its plant to identify valves that are susceptible to pressure locking or thermal binding; 210087 9602210271 960212 A /
PDR ADDCK 05000282 PDR g8[F ;
P g(g l
o USNRC NORTHERN STATES POWER COMPANY February 12,1996 Page 2
- 2. Perform further analyses as appropriate, and take needed corrective actions (or justify longer schedules), to ensure that the susceptible valves identified in 1 are capable of performing their intended safety function (s) under all modes of plant operation, including test configuration.
Attachment 1 to this letter provides our 180-day response. In this letter we have made no new Nuclear Regulatory Commission commitments.
Please contact Jack Leveille (612-388-1121, Ext. 4662) if you have any questions related to this letter.
/lftO b Michael D Wadley Plant Manager Prairie Island Nuclear Generating Plant c: Regional Administrator- Region Ill, NRC Senior Resident inspector, NRC NRR Project Manager, NRC
! J E Silberg
. Attachments: (1) Summary of Actions Taken to Address Pressure Locking and Thermal Binding of Power Operated Gate Valves at Prairie Island Nuclear Generating Plant - Units 1 and 2 (2) Affidavit u
l GL950701. DOC
SUMMARY
OF ACTIONS TAKEN TO ADDRESS PRESSURE LOCKING AND THERMAL BINDING OF POWER OPERATED GATE VALVES AT PRAIRIE ISLAND NUCLEAR GENERATING PLANT - UNITS 1 AND 2
Introduction:
Prairie Island's response to the issue of pressure locking and thermal binding (PL/TB) of power operated gate valves has been in several stages. These stages of response have occurred as new information has been received and knowledge of the issue has increased. Most of the activity has been during actions to respond to motor valve operability relative to NRC Generic Letter 89-10.
The first activity performed was the change of normal position of the Low Head Safety injection (Vessel injection) motor valves from normally closed to normally open; these four valves are among the classic pressure locking susceptible valves for a pressurized water reactor. Prairie Island Safety Evaluation #351, " Basis for Repositioning Low Head Vessel Injection Motor Valves from Closed to Open Due to Susceptibility to Pressure Locking" was developed to support this change.
The major evaluation relative to the issue was performed by Safety Evaluation #373,
" Operability Determination for Generic Letter 89-10 Valves Determined Susceptible to Thermal Binding / Pressure Locking." The primary guidance used for the evaluation was the 1992 "AEOD Special Study on Pressure Locking and Thermal Binding of Gate Valves," AEOD/S92-07 (later known as NUREG 1275, Volume 9). Additional evaluation was subsequently performed relative to the containment sump suction motor valves in our response to Tl 2515/129, " Pressure Locking of PWR Containment Sump Recirculation Gate Valves."
l A subsequent review was also performed when NRC Generic Letter 95-07 was issued.
Earlier efforts were reviewed and the screening methodology of the Westinghouse l Owner's Group Task Team on Pressure Locking and Thermal Binding was performed.
g Test procedures were reviewed to determine if any additional valves which are normally l open would be susceptible to PL/TB during testing where Technical Specification l limiting conditions for operation were not entered during the test. No additional valves l were discovered.
Note that Prairie Island is licensed as a hot shutdown plant.
Non-Motor Valve. Power Operated Gate Valves:
A search was performed for applicable non-motor operated gate valves. No additional valves beyond the scope of NRC Generic Letter 89-10 were found.
! .' Attachment i Pags 2 of 5 Summary
Description:
MV-32064, MV-32065 [MV-32167, MV-32168): Residual Heat Removal (RHR) to Vessel injection (Low Head Safety injection)
These flex wedge gate valves were determined to be susceptible to pressure locking in 1993 and were changed from their historical normally closed position to normally open and therefore are no longer a concern for pressure locking. Justification for the position change is provided in Prairie Island Safety Evaluation #351.
MV-32164, MV-32165 [MV-32192, MV-32193]: Reactor Coolant System (RCS) Loop A Hot Leg RHR Suction MV-32230, MV-32231 [MV-32232, MV-32233): RCS Loop B Hot Leg RHR Suction These normally closed flex wedge gate valves perform no accident mitigation function, and are not required to open to bring the plant to hot shutdown. Cooldown to cold shutdown is considered a non-safety related function. Therefore, PL/TB is not a nuclear safety concern. NRC Information Notice 95-18, Supplement 1, " Potential Pressure-Locking of Safety-Related Power-Operated Gate Valves," raised the concern that plant heat up after RHR isolation could raise the pressure in the valve bonnet area beyond code allowable limits due to heat transfer from the reactc ;oolant system. GL 95-07 also references French experience with similar valves in NUREG/CP-0137 (July 1994)," Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing."
In the French experience, similar valves are affected by heat transfer from the reactor coolant system. The temperatures of the bonnets on each of these valves at Prairie Island were measured during power operation. The temperature remained at local ambient conditions. Therefore this concern is not applicable to Prairie Island since the bonnets do not heat up and thus do not pressurize, from heat transfer from the connected high temperature system.
MV-32066 (MV-32169): RHR to RCS Loop B These normally closed parallel double disk gate valves perform no accident mitigation function, and are not required to open to bring the plant to hot shutdown. Cooldown to cold shutdown is considered a non-safety related function. Therefore, PL/TB is not a nuclear safety coner The bonnet temperatures of these valves were also measured at power to determine if they were susceptible to the concern raised by NRC IN 95-18, Supplement 1. They also remain at local ambient temperature and therefore this concern is not applicable since the bonnets do not heat up and thus do not pressurize, from heat transfer from the connected high temperature system.
GL950701. DOC
Attachment 'i Page 3 of 5 i
MV-32023, MV-32024, [MV-32028, MV-32029]: Feedwater (FW) to Steam Generator Isolation These flex wedge gate valves, which are susceptible to PL/TB, are normally open and l automatically close on a containment isolation signal. They are not required to open in order to prevent or mitigate an accident previously evaluated in the USAR. Failure of auxiliary feedwater, which may require reopening of these valves, is beyond the design basis. Therefore P11TB is not a design basis nuclear safety concern. These valves have been modified with SB actuators to improve their reliability by reducing inertia and reducing the possibility of thermal binding problems. The compensating spring pack of the SB actuator helps in two ways,1) it limits wedging /unwedging force due to inertia, and 2) it prevents differential expansion / contraction of dissimilar metals due to relative stem growth from causing additional wedging as cooling occurs.
MV-32096, MV-32097 [MV-32108, MV-32109]: RHR to Containment Spray Pump Suction These split wedge gate valves which would be susceptible to pressure locking are not required to function to mitigate the consequences of an accident. They were designed to provide for containment spray during the recirculation phase following a loss of coolant accident. Containment Spray is not needed after the injection phase of a design basis accident. This is documented in Prairie Island Safety Evaluations #234 and #364.
These valves are connected to the RHR system which may be in operation at 350 F.
The bonnet temperatures of the Unit 1 valves were measured during our recent plant cooldown in preparation for refueling and maintenance outage to determine if they were '
susceptible to the concern raised by NRC IN 95-18, Supplement 1. They also remain at local ambient temperature and therefore this concern is not applicable since the bonnets do not heat up and thus do not pressurize, from heat transfer from the connected high temperature system. The Unit 2 piping configuration is similar and therefore should also remain at ambient conditions during RHR cperation.
MV-32206 MV-32207, [MV-32208, MV-32209]: RHR to Safety injection Pump Suction These split wedge gate valves were determined to be potentially susceptible to pressure locking. The Unit i valves were modified in 1994 and the Unit 2 valves in 1995 by installation of bonnet vents with manual valves which are controlled administratively to prevent pressure locking.
GL950701. DOC
_ _ _.~._._ _ _ ._ _ . _ _ _ _ _ . _ _ . _ _ _ . .._ _ _ _ _ _
, *. Attachment i Page 4 of 5 L'
l MV-32075, MV-32076, MV-32077, MV-32078, [MV-32178, MV-32179, MV-32180, j - MV-32181]: Containment Sump B to RHR Pump Suction These flex wedge gate valves are required to open to provide water for core cooling during the recirculation phase. Each train contains two valves in series, both of which must open to provide containment sump water to the RHR Pump. These valves were determined to be susceptible to pressure locking.
The Unit 1 pumpside valves were modified in 1994 and the Unit 2 pumpside valves in 1995 by installation of bonnet vents with manual valves which are controlled administratively to prevent pressure locking.
The sumpside valves are cycled administratively prior to leaving cold shutdown to ensure the bonnet and the pipe between the pumpside and sumpside valve is drained backwards to the containment sump and thus are filled with air preventing the possibility of pressure locking.
MV-32195, MV-32196, [MV-32197, MV-32198]: Pressurizer Power Operated Relief Block Valves These normally open flex wedge gate valves are potentially susceptible to PL/TB should a valve be closed to isolate a leaking power operated relief. valve. Technical Specifications require the block valve to remain operable to provide back up de-pressurization capability for response to a steam generator tube rupture. Thermal binding would not be expected to prevent reopening of the block valve during this event, since the temperature decrease in the nearby pressurizer would only be about 50 F. Since Prairie Island's licensing basis is hot shutdown, cooldown to cold shutdown is considered a non-safety related function. Therefore, thermal binding is not a nuclear safety concern. On Unit 2, the valves have been modified with SB actuators, primarily as a GL 89-10 margin improvement project (control of inertia allows a higher torque switch setting while still protecting the structural limitations of the valve and actuator). A secondary benefit of the SB actuator is to reduce susceptibility to thermal binding. The Unit i valves are being similarly modified with SB actuators during the ongoing Unit i refueling and maintenance outage.
Pressure locking would not be expected to prevent reopening of the block valve during the steam generator tube rupture event. A bounding calculation of the steam generator
. tube rupture scenario using the Commonwealth Edition methodology (presented at the Region 111 workshop on GL 95-07) was performed. The calculation shows a small increase in required opening force due to pressure locking, with the total opening force well within the valve / actuator capability (at design reduced voltage using the standard Limitorque capability equation and a conservative stem coefficient of friction) such that substantial margin is maintained. Since Prairie Island's licensing basis is hot shutdown, cooldown to cold shutdown is considered a non-safety related function. Therefore, pressure locking during plant cooldown is not a nuclear safety concern.
GL95D701. DOC
- Pags 5 of 5 It should also be noted that at Prairie Island, leaking power operated relief valves are rare, such that normally all block valves are open and P11TB is not a concern.
Conclusion:
Actions associated with NRC Generic Letter 95-07 " Pressure Locking and Thermal Binding of Safety Related Power-Operated Gate Valves" are considered complete.
a 1
J a
b-l i ;
e e
GL950701. DOC
i
- 6 UNITED STATES NUCLEAR REGULATORY COMMISSION NORTHERN STATES POWER COMPANY PRAIRIE ISLAND NUCLEAR GENERATING PLANT DOCKET NO. 50-282 DOCKET NO. 50-306 GENERIC LETTER 95-07, PRESSURE LOCKING AND THERMAL BINDING OF SAFETY-RELATED, POWER-OPERATED GATE VALVES Northern States Power Company, a Minnesota corporation, by this letter dated February 12, 1996 hereby submits information required by Generic Letter 95-07 for the Prairie Island Nuclear Generating Plant.
This letter contains no restricted or other defense information.
NORTHERN STATES POWER COMPANY By /
Michael D Wadley Plant Manager Prairie Island Nuclear Generating Plant On this day o M#M ,
beforemeanotarypublicinandforsaidCounty,personallgap[ eared, Michael D Wadley, Plant Manager, Prairie Island Nuclear Generating Plant, and being first duly sworn acknowledged that he is authorized to execute this document on behalf of Northern States Power company, that he knows the contents thereof, and that to the best of his knowledge, information, and belief the statements made in it are true and that it is not interposed for delay.