Forwards Revised Sample Plan & Evaluation Procedures for Overinsp Program.Procedures Will Be Implemented on 840701
ML20093L167
Person / Time
Site: Clinton Constellation icon.png
Issue date: 06/18/1984
From: Hall D
ILLINOIS POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20093L171 List:
References
0982-L, 982-L, U-10164, NUDOCS 8407310316
Download: ML20093L167 (2)


Text

c- ._. ,

b

,, A 0982-L ILLINDIS POWER COMPANY U-10164 CLINTON POWER STATION. P.O. BOX 678 CLINTON. ILLINOIS 61727 June 18, 1984 Docket No. 50-461 jPRIN2f PAL STAFF l- RA h uos, ,c / g'4/

Mr. James G. Keppler 1/RA DE ef ()

Regional Administrator $28A DRMSP Region III RC ; ogy3 U.S. Nuclear Regulatory Commission Ede SCS 799 Roosevelt Road 5GA ML , i Glen Ellyn, Illinois 60137 L:NF l Filo g

Subject:

Illinois Power Overinspection Program Sample Plans

Dear Mr. Keppler:

The Illinois Power Company (IP) Overinspection Program consists of two major parts, Baldwin Associates (BA) Field Verification (FV) and IP Overinspection (IP OI) process. The Sample Plans and Evaluation Procedures associated with the total Overinspection Program have been reviewed and changes to the procedures are required to improve the performance.

The following items are germane:

1. Definition of sample lots should be made consistent with the methods of defining work packages.
2. The sample plans were developed prior to the inspection checklists and considered that components and items of interest would be classified critical or non-critical.

In the current program, inspection attributes rather than components or items were classified as critical or non-critical.

3. Under the present procedures, one attribute (rather than an item) rejected out of many in a lot may cause the lot to be rejected.
4. Evaluation of acceptability should be based on the number of attributes in a lot inspected rather than the number of travelers or components.
5. Identifying and sampling items within a traveler is administratively complex and time consuuing.

Inspecting all items on a traveler as identified by a Turnover Package Scope is more efficient and provides a greater degree of inspection of hardware represented by 1

8407310316 840618 Ol PDR ADOCK 05000461 jug" g g $84 hr G PDR '

i{\

c, 3 the' traveler.. Therefore, travelers may oe selected.as theLsample element instead'of an item within a traveler. j The proposed changes described in Attachments 1 through 4 are summarized as follows:

1. 1Nie method of developing sample lots'by identifying-items within travelers'has been broadened to include the following:

Identify ~and sample travelers within a Turnover Package.

Identify and sample items within a specified area.

Identify and-sample items within a commodity such

-as. conduit hangers, large bore pipe hangers, etc.

2. As each attribute represents a discrete quality decision,- the method of determining acceptability of a lot is changed from acceptance based on an item count to acceptance based on attribute count. Separate charts have been included to determine acceptability of a lot to a 95-5 critical and 95-15 non-critical criteria.
3. Single normal. and single reduced sample tables for critical and non-critical populations are replaced by one sample table to be used in all cases where less than 100% inspection is required.
4. The number of administrative forms is reduced from three to one which may be used by all disciplines.

Illinois Power intends to implement these procedures on July 1, 1984. Should you have any comments, please contact me.

Sin cerely - yours ,

. . Hall Vice President RLB/ lag Attachments cc: NRC Resident Inspector Director, Office of I&E, USNRC, Washington, DC 20555

. Illinois Department of Nuclear' Safety

,. s