Text
_ _ _ _ _=- . _ _ . . .-_ _. . _ _ _ _ _ . .. _ - _ _ _ _ _ _ - - - _ _ . . _ . . .
e 4 g' .
Babcock &Wilcox
~~
AFFIDAVIT OF JAMES-H. TAYLOR
~
\.
A. My name is James H. Taylor. I am Manager of Licensing in the Nuclear Power Generation Division of Babcock & Wilcox, and as such l I as authorized to execute this Affidavit.
B. I as familiar with the criteria applied by Babcock & Wilcox to de- '
termine wJ. ether certain information of Babcock & Wilcox is proprietary and I am familiar with the procedures established within Babcock & Wilcox, particularly the Nuclear Power Generation Division (NPGD), to ensure the proper application of these criteria.
C. In determining whether a Babcock & Wilcox document is to be classi-fiqd as proprietary information, an initial determination is made, by the unit manager who is responsib1? for originating the document askowhetheritfallswithinthecriteriasetforthinParagraphD hereof. If the information falls within any one of these criteria, it is classified as proprietary by the originating unit manager.
This initial determination is reviewed by the cognizant section manager. If the document is designated as ~ proprietary, it is re-viewed again by Licensing personnel and other management within NPGD as designated by the Manager of Licensing to assure that the '
regulatory requirements of 10 CFR Section 2.790 are met.
D. The following information is provided to demor. strate that the pro-visions of 10 CFR Section 2.790 of the Commission's regulations have been considered:
(1) The information has been held in confidence by the Babcock &
Wilcox Company. Copies of the document are clearly identified as proprietary. In addition, whenever Babcock & Wilcox transmits the information to a customer, customer's agent, ,
Potential customer or regulatory agency, the transmittal re-quests the recipient to hold the information as proprietary.
Also, in order to strictly limit any potential or actual customer's use of proprietarv information, the following 840209014505000 840206 8
{DRADOCK
- l 4
i l
Babcock &Wilcox 1 l
AFFIDAVIT OF JAMES H. TAYLOR (Cont'd) provision is included in all proposals submitted by Babcock j 4
& Wilcox, and an applicable version of the proprietary j
- provision is included in all of Babcock & Wilcox's contracts
i
" Purchaser may retain Company's Proposal for use in ;
connection with any contract resulting therefrom, and, for that purpose, make such copies thereof as may be necessary. Any proprietary information concerning Company's or its Suppliers' products or manufacturing processes which is so d?signated by Company or its i
Suppliers and disclosed to Purchaser incident to the .
performance of such contract shall remain the property of Company or its Suppliers and is disclosed in confi-dance, and Purchaser shall not publish or otherwise j disclose it to others without the written approval !
of Company, and no rights, implied or otherwise, are l
granted to produce or have produced any products or to practice or cause to be practiced any manufacturing i i
processes covered thereby.
l Notwithstanding the above, Purchaser may provide the ,
NRC"or any other regulatory agency with any such pro-prietary information as the NRC or such other agency may require; provided, however, that Purchaser shall first give Company written notice of such proposed disclosure and Company shall have the right to amend l such proprietary information so as to make it non-pro-prietary. In the event that Company cannot amend such proprietary information, Purchaser shall, prior l to disclosing such information, use its best efforts j to obtain a commitment from NRC or such other agency to have such information withheld from public inspection.
l l l
l (2)
1 1 . .
-a Babcock &Wilcox AFFIDAVIT *OF JAMES H. TAYLOR (Cont'd)
Company shall be given the right to participate in pursuit of such confidential treatment."
(ii) The following criteria are customarily applied by Babcock &
Wiicox in a rational decision process to determine whether the information should be classified as proprietary. Information may be classified as proprietary if one or more of the following criteria are met.
- a. Information reveals cost or price information, commercial strategies, production capabilities, or budget levels of Babcock & Wilcox, its customers or suppliers. .
b.' The information reveals data or material concerning Babcock
& Wilcox .*esearch or development plans or programs of present or potential competitive advantage to Babcock &
Wilcox.
- c. The use of the information by a competitor would decrease his expenditures, in time or resources, in designing, producing or marketing a similar product.
- d. The information consists of test data or other similar data concerning a process, method or component, the application of which results in a competitive advantage to Babcock &
Wilcox.
- e. The information reveals special aspects of a process, method, component or the like, the exclusive use of which results in a c'o mpetitive advantage to Babcock & Wilcox,
- f. The information contains ideas for which patent protection may be sought.
(3)
^
j Babcock &WNcoK AFFIDAVIT OF JAMES H. TAYLOR (Cont'd)
The document (s) listed on Exhibit "A", which is attached hereto and made a part hereof, has been evaluated in accordance with normal Babcock 8 Wilcox procedures with respect to classification i and has been found to contain information which falls within one or more of the criteria enumerated above. Exhibit "B", which is l attached hereto and made a part hereof, specifically identifies l the criteria applicable to the document (s) listed in Exhibit "A".
l (111) The document (s) listed in Exhibit "A", which has been made avail-i able to the United States Nuclear Regulatory Commission or the
! Atomic Safety and Licensing Board was made available in confidence with a request that the document (s) and the information containe'd therein be withheld f rom public disclosure.
(iv) The information is not available in the open literature and to the best of our knowledge is not known by Combustion Engineering, EXXON, General Electric, Westinghouse or other current or potential domestic or foreign competitors of B&W.
(v) Specific information with regard to whether public disclosure of the informatica is likely to cause harm to the competitive position of Babcock & Wilcox, taking into account the value of the information to Babcock & Wilcox; the amount of effort or money expended by Babcock & Wilcox developing the information; and the ease or difficulty with which the information could be properly duplicated by others is given in Exhibit "B".
E. I have personally reviewed the document (s) listed on Exhibit ' A' and have found that it is considered proprietary by Babcock &
Wilcox because it contains information which falls within one or more of the criteria enumerated in Paragraph D, and it is informa- -
tion which is customarily held in confidence and protected as proprietary information by Babcock & Wilcox. This report com-prises information utilized by Babcock & Wilcox in its business which afford Babcock 8 Wilcox an opportunity to obtain a competitive advantage over
Babcock &Wilcox those who may wish to know or use the inforr.ation contained in the document (s).
/
/
/ -
[ JAMESH. TAYLOR [
State of Virginia)
) 55. Lynchburg 1 City of Lynchburg) t James H. Taylor, being duly sworn, on his oath deposes and says that -
he is the person who subscribed his nare to the foregoing statement, and that the matters and facts set forth in the statement are true.
/ JAMES H. TAYLOR [
Subscribgandswornbeforeme this 6 - day of %Lw 1984. -
%u )n t-NotaryPublicinandfohtheCity of Lynchburg, State of Virginia
~
My Comission Expires 4./[7 /9 74 J
(5)
j EXHIBIT A Reference Document No. (for '
Replies to Interrogatories) Document No.
33 TDR-341 35 GPUN-82-359 36- 23-1138065-21 37 27-1137838-01 38 844-0704-01-01 39 RDD: 83:5170-01:01 40 RDD:83:5156-01-01:01 41 64-1140812-00 42 PAS-09 .
47 SP-1101-22-008 48 GPUN 83-005 49 GPUN 83-110 58 097.4 C/ 0127C/0106 84 : 5 59 TDR 83-506 60 Battelle Report " Overview of Progress in the TMI-l Tube Cleaning Experime"t'",
January 31, 1983
- 61. SP-1101-08-001 Rev. 6 62 Battelle Report "Short Term Corrosion Evaluation of Kinetically Expanded Tubes in Mockup Tube Sheets", November 21, 1983
A EXHIBIT B (continued)
Reference 33 TDR-341 Criteria
~
Page IX-4, Section F Repair Procedure, para. 2, line 1 c-f Page IX-4, Section F Effects of Repair Procedure on Corrosion Concerns, para. 2, line 6 c-f Page IX-4, Section F , Effects of Repair Procedure on c-f Corrosion Concerns, para. 3, lines 3.5.6,9 c-f Page IX-21. Tube Cleaning Series 2, lines 1,5,8,13,16,19 c-f Page IX-21, Tube Cleaning Series 3, line 2 c-f Page IX-29,34. TMI-1 Kinetic Expansion Repair Corrosion Tests, Conclusions, line 8 c-f Page IX-30, Summary, lines 3,7,10,11 c-f Page IX-30, Conclusion, lines 4,8,13 c-f Reference 35, line 1 c-f I .
')
l ..
.s
. EXHIBIT B (continued)
Document No. GPU-82-359 GPUN-82-355 23-1138065-00 83-770753-10 Reference No. 35 Document GPUN-82-359 Page 1, Attachments (3) c-f Page 1, para.1, line 2 c-f Document 83-770753-10 Description / Mark No., lines 1,3 c-f Document 23-1138065-00 Title, line 1 c-f Iddex, lines 5,6 c-f Page 1 A, description, lines 1,3 c-f Page 2, description, lines 1,2 c-f Page 14, material name c-f Page 15, para.1, line 1 c-f Page 16, lines 2,4 c-f Page 17, para.1, lines 1,2,3 c-f Page 17, discussion (2)(a) c-f Page 18, (b),(c),(d),(e),(f),(g) c-f Page 19, sample description, lines 1 & 2 c-f
- starred 1tne c-f Page 21, lines 8.11,12,13 c-f Page 22, elements determined c-f sample no. 3,4 & 5 Page 23, elements determined c-f sample no. 3,4, & 5 Page 24, materici name c-f Page 25, line 1, raw material certs, line 6,7 c-f Page 29, mark 1) & 2) c-f
~
- 5 EXHIBIT B (continued)
Document 23-11389065-00 (continued)
Page 30, mark 1) c-f Page 39, i f nes 10,13,14,15,16,17,19,21,23 c-f Page 50, description, line 1 c-f Page 51, powder type c-f l Page 52, entire page c-f l
Page 53, entire page c-f Page 54, line 1 c-f Page 65, line 2, raw material cert *,, lines 6 8 7 c-f Page 66, entire page c-f Page 70, para.1, line 1, subj. line 3 c-f Page 71, item 11, line 2 c-f i
' Page 72, waiver conuient 1 & 2 c-f iPage 73, 3., ifne 3 c-f Page 75, item 15, lines 2 & 3, Item 16, lines 3 & 4 c-f l
item 17, line 1, item 10 line 1 Page 76, item 15, item 16, line 3 c-f Page 77, description 8 spec. regs. c-f Page 78, para.1, lines 3,4,7, & 8 c-f Page 78, sections 2.1 through 2.4 c-f Page 79, table, paragragh 1, lines 2 & 3 c-f Page 80, section 15, line 1 c-f Page 80, section 16, line 2 c-f l Page 81, title no. 2 c-f
( Page 82, subject line 5, para.1, lines 2 8 4 c-f para. 2, lines 2,4,5 8 7, para. 3, line 2 Page 83, line 2 c-f Page 84, para.1, line 2, para. 2, line 2 c-f Page 85, lines 6,10,11 c-f l
l_ _ _ _._ _..- _ _._ . . . _ . _ _ . . .____ . _ . _ _ _ __ _ _ _ _ _ _ _ , _ _ __
m EXHIBIT B (continued)
Document No. 23-1138065-21 Reference No. 36 (Locations) (Affidavits)
Title, line 2 c-f Documentation lines 5 & 6, Note line 2 c-f l
Page 1, line 14 c-f Page 2, description lines 2 & 4, sub-supplier c-f lot nos., items 2 & 3 Page 5, material name c-f Page 6, lines 1,3 c-f Page 7, line 1 c-f c-f
, Page 8, para.1, line 1, para. 2, if ne 3, ,
para. 3, line 1 Page 9, lines 1,2 & 8 c-f Page 10, title c-f Page 10, core weights, lines 1-30 c-f V.O.D. , lines 1-30 c-f Page 11, line 7 c-f Page 12, subj line 3, etment (a) lines 2 & 3, c-f conunent (b) lines 18 4, coment (c) lines 1,2 3 4, comument (d) line 2 Page 13, (c) line 2 c-f l Page 14, sample description line 1 c-f Page 14, table line 3 c-f i
Page 15, subj, lines 2,5,10,13 c-f Page 16, line 4 c-f Page 17, general description, line 3 c-f l Page 18, general description, line 3 c-f Page 19, line 1, raw material certs lines 6,7 c-f Page 20, line 1, raw material certs lines 6,7 c-f Page 21, line 1, raw material certs lines 6,7 c-f
EXHIBIT B (continued) l l
Reference No. 37 Document No. 27-1137838-01 -- l Locations Criteria Drn Doc. Title c-f Page 1 Line 4 c-f Page 4 Section 1.0 Lines 1,2 c-f Page 4 Section 2.0 Lines 1 and 3 c-f Page 4 Section 3.2 Line 1 c-f Page 5 Section 4.1 Line 1 c-f Page 5 Section 4.2 Line 3 c-f Page 6 Section 5.0 Lines 1,4 c-f P, age 6 Section 6.1.1 Line 3 c-f ,
Page 6 Section 6.1.2 Line 2 c-f Page 6 Section 6.2 Line 3 c-f Page 6 Section 6.3 Line 3 c-f Page 7 Section 6.4 Title c-f Page 7 Section 7.0 Lines 1,6 c-f Page 7 Section 8.0 Lines 1,3 c-f l
l
.~.
EXHfBIT B (continued)
Reference Document No. 38 Tech Report on Immunol Locations Criteria T,itle Page Line 4 c-f --
Memo Murphy to Birks Lines 1,5,6,8,12,13,15,17,18,20,21 c-f First page of report, Title line 2 c-f Purpose Line 2-3 c-f Pt< pose Margin Note Lines 1 & 3 c-f Summary of Work Section 1 Lines 3,8,9,10,11 c' Summary of Work Section 1 Margin Note Lines 2 & 3 c-f Summary of Work Section 2 Lines 1,2,5,6,7 c-f Summary of Work Section 2 Margin Note Line 1 c-f Summary of Work Section 3 Lines 1,2 & 4 c-f Summary of Work Section 3 Margin Note Line 2 c-f Summary of Work Section 4 Line 2 c-f Summary of Work Section 5 Lines 18 6 c-f .
Summary of Work Section 6 Lines 1,5,8,10 c-f Summary of Work Section 6 Line 1 c-f Summary of Work Section 7 Line 1 c-f Susmary of Work Section 7 Margin Note Line 2 c-f Results Section 1 Lines 10 811 c-f Results Section 1 Margin Note Lines 2 & 4 c-f Results Section 2 Lines 1,2,3,5,6,7,8,10,11,13 c-f Results Section 2 Margin Note Line 4 c-f Results Section 3 Lines 1,2,3,7 8 8 c-f Results Section 3 Margin Note Line 4 c-f Results Section 4 Lines 1,7,9 c-f Results Section 5 Lines 2,4 8 6 c-f Results Section 5 Margin Note Line 1 c-f Results Section 6 Lines 2,4,9,12,14 c-f Results Section 6 Margin Note Line 1 c-f Results Section 7 Lines 2,4,7 c-f Conc. Section 1 Lines 1,5,6,7,8 c-f Conc. Section 1 Margin Note Line 1 c-f Conc. Section 2 Lines 1,2,5 c-f Conc. Section 2 Margin Note Line 2 c-f Conc. Section 3 Lines 3,5,6 8 8 c-f Conc. Section 3 Margin Note Line 5 c-f
i
.s EXHIBIT B (continued)
Reference No. 38 (continued)
~
locations. Criteria Conc. Section 4 Lines 2,3,4,7,8, c-f Conc. Section 4 Margin Note Lines 14 2 c-f Recommendations Lines 2 8 3 c-f Table of Contents Items 2.1.B, 2.2, 3.0 "A", c-f 3.0 "B", 3.0 "C", 3.0 "E", ,
3.0 "F", 3.0 "H" I 1.0 Intro. Lines 1,4,5,6,7,9,11,12,13,17.23,26,29 & 30 c-f 1.0 Intro (con't). Lines 2,3,4,5,10,14,16,18 c-f l Sect. 2.1 Lines 1 8 2 c-f Sect. 2.1 A. Test Procedure Lines 2,3,6,7 c-f l
Results Lines 1, 4 Sect. 2.1 B. Line 1 c-f Test Procedure Lines 1,2,4 & 6 Results Lines 3,4,5,6 Sect. 2.1 C. Test Procedure Lines 3 & 4 c-f Results Lines 3, 4 & 6 c-f Sect. 2.2 Effects of on weldability c-f Lines 1, 2 & 4 Sect. 2.2 Test Procedure Lines 1,6,11 & 12 c-f Sect. 2.2 Results Lines 1,4 c-f Sect. 2.3 First paragraph lines 1,2 & 4 c-f Sect. 2.3 Test Procedure Lines 4,5,7,8,9,10,13,15,16 c-f 17,18,20 Sect. 2.3 Results Lines 1,2 8 3 , c-f i Sect. 2.4 Line 5 c-f Sect. 2.5 Entire Section c-f Sect. 2.6 Para.1, Line 1 c-f Sect. 2.6 Test Procedure Lines 1,4 c-f Sect. 2.6 Results Line 2 c-f Sect. 2.7 Para. 1 Lines l'a 3 c-f Sect. 2.7 Test Procedure Line 6 c-f Sect. 2.7 Results Line 2 c-f
m EXHIBIT B (continued)
Reference No. 38 (continued) locations Criteria
~
Sect. 2.8 Para.1 Line 5 - c-f Sect. 2.8 Test Procedure Line 1 c-f Conclusions Lines 1,2 & 4 c-f Page 3-1 Subj. Line 2, Intro Lines 1,3,6,10,12 c-f Conc 1 Lines 1,3 & 4
. Page 3-2 (4) Lines 1 & 2, (5) Lines 1 & 2, c-f Procedure Line 4 Page 3-3 First line below Table 1: Surface Analysis, c-f Para. 1 Line 3 Figures 1,2,3,4, Figure Description c-f Page 3-6 Table II Lines 2 & 4 c-f Para. 2, Lines 2 & 3 Page 3-7 Subj. Line 1, Ref. Line 2, c-f Memo Lines 2,9,10,11,16,19 Page 3-8 Lines 2,7 c-f Page 3-10 Subj. Line 1, Summary Lines 2,3,10,11 c-f 1 Introduction Lines 1,5,7,9,11 c-f Page 3-11 Introduction Lines 1,2,4 & 5 c-f Investigation Line 2 Results Lines 4 & 6 c-f Page 3-12 Conc 1 Lines 1,2 8 6 c-f Page 3-13 Block No. Lines 2,6,10,14,18,22 c-f
- starred line Page 3-16 Para. 1, Lines 2 8 5 c-f Page 3-17 Conclusion Line 2 c-f Page 3-18 Picture Captions c-f Figure 1 Line 2 Page 3-19 Subj. Line 1, Ref. Line 1 c-f Memo Lines 1,5,6,14 Page 3-20 Chromatog. Anal. Entire Section c-f Infrared Anal. Entire Section Page 3-21 Subj. Line 1, Memo Lines 2 & 3 c-f
EXHIBIT B (continued)
Reference No. 38 (continued)
Locations Criteria Page 3-22 Description of Sample c-f Page 3-26 Subj Line 1. Memo Line 2 c-f Page 3-27 Title, Sample Description, Item 1 c-f
49 EXHIBIT 8 (continued)
Reference No. 39 Document No. ROD:83:5170:01:01 __
Locations Criteria Page 1 Subj. c-f Page 1 Para 1 Lines 3,7,9,10 c-f Page 2 Para 1 Lines 2,3,4,6 c-f Page 2 Para 3 Line 7 c-f Page 2 Para 4 Line 1 c-f Page 3 Lines 1,3,4 c-f Page 4 Lines 7,21 c-f Page 5 Lines 2,5 c-f Page 6 Test 2 Line 1, Test 3 Line 1 c-f Page 6 Test No. 4 Line 2 c-f Pa'ge 6 Test No. 5 Line 2 c-f Page 6 Test No. 5 Line 2 c-f Page 7 Sec. 5.2 Lines 1,6,7,11,12,13 c-f Page 8 Line 3 c-f Page 8 Section 5.3 Lines 1,6,11 c-f Page 9 Lines 3,12,16 c-f Page 10 Lines 2,4 c-f Page 10 Section 5.5 Lines 1,4,5 c-f Page 11 Lines 1,12 c-f Page 11 Section 5.6 Line 1 c-f Page 12 Line 1 c-f Page 12 Section 6.0 Line 8 c-f Page 13 Lines 2,7,8,9,11,13,15,17,21,25,26 c-f Page 14 Lines 1,6 c-f Figure 10 Line 3 c-f Figure 13 Line 7 c-f Figure 16 Line 6 c-f Figure 19 Line 6 c-f Figure 22 Line 7 c-f
.s EXHIBIT B (continued)
Reference 40 RDD:83:5156-01-01:01 Locations Affadavits _
Page 1, para.1, line 2 c-f Page 2, Procedures, lines 7,10 c-f Page 5, para. 1, line 4 c-f Page 5, para. 2, ifnes 6 and 11 c-f Page 6, Objective c-f Page 6 Variables, line 1 c-f Page 6, Conclusions, lines 1 and 3 c-f Page 7. Variables, line 1 c-f-Page 7. Conclusions, line 10 c-f Page 9, Variables, line 1 c-f Page 9, Conclusions, line 3 c-f Page 12, Comp. to Autoclave Treaded Oxid Cont. Sample, i lines 4 and 6 c-f Page 12, K Tracer Test, lines 3 and 4 c-f Table 2, Title line 2, [ ] Coated, Expanded, lines 1-3 c-f Table 3, [ ] Coated, c-f Table 4, No. of [ ] Coatings, [ ] lines 1-9 c-f Table 5, No. of [ ] Coatings, [ ] lines 1-10 c-f Table 6, No. of [ ] Coatings, [ ] lines 1-11 c-f Table 7, No. of [ ] Coatings, [ ] lines 1-10 c-f l
Table 8, No. of [ ] Coatings, [ ] lines 1-5 c-f l
l l
Y
I EXHIBIT B (continued)
Reference 41 64-1140812-00 Locations Affadavits .'
Page 6, Section 3.2.1.1, line 3 c-f Page 7, Section 3.2.2.3, line 1 c-f Page 8, Section 3.2.2.8, line 3 c-f Page 13, Sample Plot, y-axis label c-f Page 14. Table 1 Acceptance Criteria,1st Pass Satches, 2nd Pass Batch, 3rd Subsequent Batches, Item - Line 5 [ ] c-f Page 15, Section 1.2, line 1 c-f Page 16, Section 3.1, lines 5-8 c-f Page 17, Section 3.3, line 1 c-f Page 17, Section 3.4.1, line 1 c-f i Page 17, Section 3.4.3, line 1 c-f ,
o%.
EXHIBIT B (continued)
Reference 42 PAS-09 __
Locations Criteria Page 1 Para. 2 Line 1 c-f Page 1 Para.3 Lines 1,2,3,5 c-f Table 1 Line 9 c-f TMI-1A Title, Y-Axis Label c-f TMI-18 Title, Y-Axis Label "
c-f Reference 47 SP-1101-22-008 Locations Criteria i
Summary of Change 4.4.2.4 Line 2, 4.4.4.4 Line 2 c-f Section 4.4.4.4 Line 1 c-f Section 4.4.4.5 Line 1 c-f Table 2 Note Line 1 c-f Table 3 Line 26 c-f Reference 48 GPUN-83-005 Locations Criteria Page 2 Item 3,4,5,6 c-f Reference 49 GPUN 83-110 Locations Criteria Page 1 Para 2 Items 1,3,5 c-f
EXHIBIT B (cort.)
Reference 58 Westinghouse Document 0914C/0127C/010684:5 _
Locations Criteria Page 39 Table 5-2 Note 3 Line 1 c-f Page 52 Para 2 Line 10 c-f Reference 59 TDR 83-506 Locations Criteria Section 6.3 Paragraph 3 Line 1 c-f i -
\
EXHIBIT 8 (continued)
Reference No. 60 Battelle Columbus Lab. Report, January 31, 1983 Locations Criteria Page 5, Para. 2, Line 8 c-f Page 6. Lines 24-32,34,36,38,39,40,41,44 c-f Page 10, Para. 2 Line 5 c-f Page 11, Beaker Cleaning Series 2, Lines 1-4 c-f Page 11, Beaker Cleaning Series 3, Lines 1,3,5,7 c-f Page 11, (a), (b), (e), (f) c-f Page 13, Lines 17-19,21,23,24,27,28,31,32 c-f Page 15, Lines 3,4,13,14,15,16,22 c-f i Page 16 Para. 2, Lines 1,2,6,8,10,13 c-f Page 16, Para. 3 Line 3 c-f Pa'ge 17, Para. 3, Lines 3,4,5,6 c-f Page 18, Para. 3, Line 5 c-f Page 19, Para. 2, Line 5 c-f Page 20. Para. 2, Line 1 c-f l Figure 14, Line 2 c-f Figure 15, Line 2 c-f Figure 16, Lines 2 and 3 c-f Figure 17, Line 2 c-f Figure 18, Graph and Line 1 c-f Figure 19, Graph and Line 1 c-f l
Figure 20, Graph and Line 1 c-f Figure 21, Graph and Line 1 c-f Figure 22, Graph and Line 1 c-f
! Figure 23, Line 2 c-f Figure 24, Line 2 c-f Figure 27, Line 2 c-f Figure 28, LIne 2 c-f Figure 29, Line 2 c-f Figure 30, Line 2 c-f Figure 31, Line 2 c-f Figure 32, Line 2 c-f Figure 34, Line 2 c-f
- _ ---- . . - - - . - _ _ _ _ _ _ _ __ _ _ _