.7-e UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOARD

.'In the Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289

)

(Restart)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

AFFIDAVIT OF EDR3.2-u.

WALLACE I

County of Morris

)

)

ss.

State of New Jersey

)

EDWARD G. WALLACE, being duly sworn according to law, deposes and states as follows:

1.

I am the Manager, PWR Licensing, for GPU Nuclear Corporation.

I am familiar with the schedule for installation of the hot leg high point vents at TMI-l and the purpose for which these vents will be used once installed.

The following information is true and accurate to the best of my knowledge and belief.

2.

It is anticipated that the major pieces of equipment and other materials needed for installation of the vents will be received on site by the end of 1982.

3.

The engineering effort for this modification was begun in December, 1980.

The detailed design engineering l

is expected to be completed in January, 1983, with the issuance of engineering drawings for the piping supports and cable conduit.

I F211240319 821122 l

PDR ADOCK 05000299 l

0 PDR

m,_.w_

-w-

-. av

~

ru,

- +-

o.

2 --

4.

Construction of all elements of the vent system will take approximately six months from the time engineering is completed, if one shift per day is utilized.

If two shifts per day are employed in constructing this system, construction time would be reduced to four months, i.e.,

the earliest-expected completion would be in May, 1983.

5.

The. construction effort associated with, installation of the hot leg vent system is composed of the following elements:

l A.

Mechanical Installation i.

Installation of approximately 100 feet of pipe and associated piping supports.

ii.

Mounting for four solenoid operated valves, four hydrostatic test valves and four block valves.

iii.

Mounting of two differential pressure transmitters, two orifice flow devices and two rupture discs, iv.

Installation of a platform on top of the secondary shield wall "D" ring under which electrical cables l

l will be run.

I B.

Electrical / Instrumentation Installation i.

Installation of 120 seismic cable supports with anchor bolts.

ii.

Installation of approximately 1000 feet of cable conduit containing seven cables from the control room to the reactor building penetrations, eight cables from the penetrations to the valves, and four power and four instru-msnt cables from the penetration to the differential pres-sure transmitters.

__u._- _ :

i J

i i

iii.

Termination of cabling ab valves, :.natr:-

mentation, switches, main control panel and other internal wiring.

C.

Inspectior..

This modification is : assified as nuclear safety related and must be ecmpletely inspected by Qcalit.y Control persor.nel throughout construction.

D.

T,e_sti_ng.

The he: leg vent system must be fully test.ed to demonstrate its operability and cor.formance to design requirements.

l 6.

Construction of the hot icq vent system, as ' described in paragraph 5 above, requires considerabic access to the containment and the control room and therefore cannot be in process concurrent with hot functional testing.

The hot. test program associated with steam generator repairs is scheduled to begin in March, 1983.

7.

Upon completion and acceptance of the hot leg vent system, the only instructions previded to the control room operators for use of the vent system will be for inadequate 1

l core cooling sit.uations, with non-condensible gases present l

ir. tne primary system.

.: /

l DNA U U G ^.. '.h.'/& w Edward G. Wallace Subscribed to and sworn before me this 22nd day of November, 1982.

t 4

.a. &

Sc'tsryjf;b1T y 4 WARf '.'E 4 9tir 1JISET W kst fi. ** ee N.tm

.My 007.nssion Expires:

i

. x-

-- w -

- _ - ~.

e UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AMD LICENSING APPEAL' BOARD

~In the Matter of

)

)

. METROPOLITAN EDISON COMPANY

)

Docket No.-50-289

)

(Restart)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

f CERTIFICATE OF SERVICE I hereby certify that copies of the foregoing " Licensee's Response to Appeal Board Memorandum and Order of November 5, 1982" and " Affidavit of Edward G. Wallace" were served this 22nd day of November, 1982, by hand delivery upon the parties identified by an asterisk and by deposit in the U.S. mail, first class, postage prepaid, to the other parties on the attached Service List.

=

Thomas A. Baxter, P.C.

-..a a

- -. ~..

6 O

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289

)

(Restart)

(Three Mile Island Nuclear

)

. Station, Unit No. 1)

)

SERVICE LIST Chai==n Nunzio J. Palladino

  • Dr. Reginald L. Gotdly U.S. Nuclear Regulatory Ocarmission Panic Safety and Licensing Appeal Washingtm, D.C.

20555 Board Panel U.S. Nuclear Regulatory Otzrmission n=4==ioner Victor :ilinsky Washington, D.C.

20555 r

U.S. Nuclear Regulatory &=4anim Washington, D.C.

20555 Ivan W. Smith, Esquire maiman Cm=4==ioner James K. Asselstine Atranic Safety and Licensing Board U.S. Nuclear Regulatory Ozrmission U.S. Nuclear Regulatory Comnission Waahington, D.C.

20555 Washington, D.C.

20555 n=4 maimer John F. Ahrarne Dr. Walter H. Jordan U.S. Nuclear Regulatory n=4*aion Atanic Safety and Licensing Board Washington, D.C.

20555 Panel 881 West Outer Drive Ccurmissioner 'Dxxnas M. Ibberts Oak Ridge, Tennessee 37830 U.S. Nuclear Regulatory & = 4caion Washingtcm, D.C.

20555 Dr. Linda W. Little Atcxric Safety and Licensing Board Docketing and Service Secticn Panel Office of the Secretary 5000 Hermitage Drive U.S. Nuclear Regulatory n=4=aion Raleigh, North Carolina 27612 Washington, D.C.

20555 l

James M. Cutchin, IV, Esquire Gary J. Edles, Esquire Office of the Executive Iegal Director ma 4==n U.S. Nuclear Regulatory n=inaim Atcznic Safety and Licensing Appeal Washington, D.C.

20555 t

Board U.S. Nuclear Regulatory n = laaion John A. Iavin, Esquire Washingtcm, D.C.

20555 Assistant Cotnsel Pennsylvania Public Utilty Ocmnission I

  • Dr. John H. Buck P.O. Box 3265 Atcmic Safety and Licensing Appeal Harvinhurg, Pennsylvania 17120 Board Panel I

U.S

  • Nuclear Regulatory o=i==im Ibbert Adler, Esquire l

Washingtcm, D.C.

20555 Assistant Attorney C = ral 505 Executive riouse P.O. Box 2357 Marriahurg, Pennsylvania 17120 l

x a -,:.....

- s a

Jordan D.'Odl@, M'4ve

~ 2320 Marth Second Street Harri =h7, Pennsylvania 17110

' ~ Ms. Iouise Bradford __

1MI AUIRP

.=' 1011 Green Street Marriah _7, Pennsylvania 17102

..^

Ellyn R. Weiss, M'im Narnrwg & Weiss 1725 Eye Street, N.W., Suite 506 Washington, D.C.

20006 Steven C. Sholly thion of Concerned Mar *4=ts 1346 Cu.-cticut Avenue, U.W., Suite 1101 Washington, D.C.

20036 f

Gail B. Phelps At e r 245 West Ph41

  • 1nhia Street York, Pennsylvania 17404 WI114== S. Jordan, III, M'4 re Marnrwt & Weiss 1725 Eye Street, N.W., Suite 506 Washington, D.C.

20006 Chauncey 1Gepford Judith H. Johnsrud Envia.u-eital Coalition on Nuclear Fower 433 orlan$o Avenue State College, Pennsylvania 16801 i

Marjorie M. Annodt R. D. 5 Coatesville, Pennsylvania 19320 1

l

, =,... - -