ML20069G789

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Section Modules Error in Adlpipe. Initially Reported on 830128.Error Exists in Adlpipe Pipe Stress Analysis Program Where Section Modules Used for Stresses in Reduced Branch Outlets.Study Underway
ML20069G789
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 01/28/1983
From: Lageraaen A
BURNS & ROE CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
REF-PT21-83-777-000 BRGO-83, BRGO-83-000, BRGO-83-1, PT21-83-777, PT21-83-777-000, NUDOCS 8303280156
Download: ML20069G789 (2)


Text

, . = _ -..

g

' MD MD\V/LRN

@ Burns and Roe,Inc.

,p g _7 f

185 Crossways Park Drive e Woodbury, New York 11797 s Telephone (516) $h kJ00 _Q)

TWX 510 2212195 m Cable BURNS ROE WDBY Main Office -

' 550 Kinderkamack Road raden. Newersey o7e49

Subject:

. Work Order 3900/4000 (201) 265-2000 Washington Public Power Supply System.

WNP-2 Potential Reportable Deficiency Section Modules Error in ADLPIPE I January 28, 1983 BRG0-83-001 US Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive Suite-1000 Arlington, Texas 76011 Attention: Mr. J. P. Collins, Regional Administrator Gentlemen:

Per requirement of Burns and Roe Project j Procedure WNP-2-ED-003 Reporting of Defects and Non-Compliance (Nuclear Projects) , the review committee

, determined that the subject deficiency is Potential Reportable and should therefore notify NRC accordingly.

This letter confirms this notification in our telecon today, January 28, 1983. An interium report resulting from the review committee's meeting is attached.

Very truly yours,

).0 t L v v ut e w K.V J . La raaen i Licensing S pervisor AJL/jmb Attachment cc: Mr. R. Johnson - WPPSS - 1 w/l

l i

A L4 '

B303280156 830128

"[t b PDR ADOCK 05000397 l

5 PDR

. s

^

'. DEFECT AND NONCOMPLIANCE EVALUATION REPORT WNP-2-ED-003 BURNS AND ROE, INC.

(Address) Woodbury, New York Project WNP-2 Evaluation Report # 83-01 Work Order 3900 Date 1/17/83 Specific Area of Concern Section Modulus Error in ADLPIPE Jutside Contractor Involved (if any) None

1. Description of Potential Defect or Noncompliance: There is an error in ADLPIPE, a pipe stress analysis program, where the section modu]/(s is used for stresses in reduced branch outlets. In calculating the bending stresses for the reduced size branch, the ADLPIPE uses the pipe run section s for the reduced branch. This error applies only when modu the y" YEAR" parameter(columns 31-40) is input as "1972" on the ADLPIPE

" Class" card for ASME III, Class 2 and 3 analysis.

2. Date and Method of Discovery: Memo from T. Butler (Burns and Roe) to '

O. Michejda (Burns and Roe) dated 12/2/82, which identified the error to Burns and Roe Stress Department.

3. Analysis of Safety Implication: The calculated stresses in the branch connection may not be conservative and, therefore, some tees or branches may be overstressed. Burns and Roe, therefore, initiated a program to i review all ASME,Section III, Class 2 pipe systems which have used the 1972 version of ADLPIPE for stress calculations.
4. Corrective Action: -

'5. Required Review and Individual Determination:

Signature / Not Engineering Date Reportable Reportable Study Reg'd Cog. Engineering Manager Project QA Group Supv. .> / #

og. Group Supvervisor phM

~icensing Supervisor ff 4tLht.ug%

v _j V

nitiating Employee lf.

Evaluation by Vice President of Engineering and Design: (if Reg'd)

a. YFurther Review Reg'd: Engineering Study to be completed by:

Enric, ipsp Determina on of reportablity to be made after evaluation:P NRC to be informed of a Potential Deviation - c_,

O Not currently considered a Potential Deviation 4g -

'- i aY 1

y-

=

~

p;uJ'h . 2 Evaluation Report # 83-01 jjL7493 NRC Notified by l. 6,Qe VOAew Date ,)a_u d,7-8'a__ Time l( k M

b. Defect or Noncompliance is\ :

Not Check as [] 10CFR21

[lReportable C] Reportable Appropriate [3 Potential 10CFR50,55(e)

c. Other Pacilities which may be affected.-
omme:.tc _

Signature Date Time

~. Action to be Taken Licensing Supervisor Signature Date Time O