ML20063G538

From kanterella
Jump to navigation Jump to search
Forwards List of Active safety-related Equipment at Qualification Level Summarizing Seismic & Hydrodynamic Loading Qualification Status of Specific Components.Info Submitted Per SER Issue 8
ML20063G538
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 07/26/1982
From: James Smith
LONG ISLAND LIGHTING CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
SNRC-740, NUDOCS 8207290135
Download: ML20063G538 (45)


Text

_ _ _ _ _ _ __

a LONG ISLAND LIGHTING COM PANY a FLC'O s2447atsar/wwt SHOREHAM NUCLEAR POWER STATION P.O. POX 618, NORTH COUNTRY ROAD e WADING RIVER, N.Y.11792 July 26, 1982 SNRC-740 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Safety Evaluation Report Issue No. 8 Dynamic Qualification Shoreham Nuclear Power Station - Unit 1 Docket No. 50-322

Dear Mr. Denton:

Enclosed please find six (6) copies of Long Island Lighting Company's " List of Active Safety-Related Equipment at Qualifica-

, tion Level" which summarizes the seismic and hydrodynamic loading l

qualification status of specific components. This information is ,

being forwarded to facilitate the NRC staff's review of the Seismic Qualification Program in preparation for the follow-up audit. This submittal supercedes in entirety that previously submitted in SNRC-713 letter, J. L. Smith (LILCO) to H. R. Denton l (NRC), dated June 11, 1982. l The items whose qualification status is listed as "G" or "H" have been determined to be fully qualified and represent approximately 89% of the equipment required to be qualified. For the purpose of determining the percentage, all of the specific components (instruments having their own plant mark numbers) on the GE pan-els were added to the remaining BOP and NSSS items. The number of components on the GE panels totalled 1158.

Four copies of this submittal are being forwarded directly to Dr. Morris Reich at Brookhaven National Laboratory in accordance with R. L. Tedesco's letter to LILCO, dated January 28, 1981.

Your timely selection of audit items from the enclosed list is appreciated.

OO I G207290135 920726 PDR ADOCK 05000322 E pga

c. .

SNRC-740 4-July 26, 1982 Page Two Should you have any questions, please contact this office.

Very truly yours, Jh. .

a V J. L. Smith Manager, Special Projects Shoreham Nuclear Power Station JLS/ law Enclosure cc: All Parties J. Higgins Dr. Morris Reich, Brookhaven National Laboratory I

/

SHOREHAN UNIT 1 RB LIST STONE & HEBSTER ENCIHEERING CORPORATION RUN DATE 07/22/02 o JC3 HUllBER 11600 3-50RT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPitENT .RUN TIIIE 14.19.26 c LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (137 ITENSI PAGE 1 HARM EQUIPHENT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL 3 NU;BER DESCRIPTION NO. RESP VEfBOR ELEV INSP REPT HETH FREQ HTtG SHTDH STATUS ,

IG41*P-023 FUEL STORAGE POOL COOL 062G PD GOULD PUtr SC151 YES HE-325 SA 33 F2 N H

, IP42EP-005 RB CLOSED LOOP COOLING 062G PD GOLLD PUtr SC151 YES HE-354 SA 48 F3 HS H 3

(

IT46sFN-079 RB EXH BOOSTER FAN 102 PD BUFFALO FORGE SC133 YES 745-4244C SA 51 F2 CS,HS H g

IT46xFLT-01 RBSVS FILTER TRAINS 105 PD FARR CO SC112 YES D-56291 SA/ SAT 11 'F2 CS HS H -3 IP42eTH-026 RBCLCH HEAD TAtH 114 PD BUFFALO TAtM SC151 YES tM(B125-IA SA F2 HS D 1R24xtlCC-111H HTR CNTRL CNTR 115 ED SQUARE D CO SC150 YES 108-1.01-L2 HBT 4 F CS.HS H 1

q 1R24xitCC-111X HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01-L2 IST 4 F CS.HS H IR2%xitCC-111Y HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CD SC78 YES 108-1.01-LZ IBT 4 F CS HS H g) l IR24xtlCC-111Z HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CO SC78 YES 108-1.01-L2 HBT 4 F CS.HS H g3 1R24xitCC-112H HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CD SC150 YES 108-1.01-L2 tBT 4 F CS,HS H ,

IR24xHCC-112X HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CO SC78 YES 108-1.01-L2 IBT 4 F CS.HS H

,) 1R24xitCC-112Y H") TOR CONT CNTRe BUS 1 115 ED SQUARE D CD SC112 YES 108-1.01-L2 HBT 4 F CS,HS H  ;

1R24xitCC1111 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CO SC40 YES 108-1.01-L2 IET 4 F CS.HS H l ' ' 1R24xitCC1112 fl0 TOR CONT CNTR BUS 1 115 ED SQUARE D CD SC113 YES 108-1.01-L2 HBT 4 F CS.HS H

)

1R24xtICC1113 HOTOR CONT CNTRs BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01-L2 tBT 4 F CS,HS H

3 1R24xitCC1114 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D C0 SC151 YES 108-1.01-L2 IBT 4 , F CS.HS H f 1R24xHCC1117 tt0 TOR CONT CNTR, BUS 1 115 ED SQUARE D CD SC40 YES 108-1.01-L2 IBT 4 F CS HS H 1R24xitCC1118 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SC113 YES 108-1.01-L2 IST 4 F CS HS H

)

1R24xttCC1119 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SC40 YES 108-1.01-L2 PET 4 F CS.HS H 1R24xttCC1121 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CD SC40 YES 108-1.01-L2 IBT 4 F CS,HS H

. ,)

_ 1R24attCC1122 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D C0 SC79 YES 108-1.01-L2 tBT 4 F CS.HS H CS = COLD SHUT DOHN P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 3 -JULY 1982 D : DUCT 110VNTED PC =PRIHARY CONT. BIAXIAL TESTING A = REEVALUATION C0tFLETE DA =DYHAllIC ANALYSIS PL = PEDESTAL SC SECONDARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: nut!BER IN F = FLOOR tt00HTED QP = QUALIFIED BY / = LOCATED CH CONT. C =S/H RECOHifENDATION TO LILCO ' TYPE HTtG' COLUIN IS HS =!!Of STANOBY PIPING ANALYSIS I HALL D = QUAL DOC RECEIVED QUANTITY OF ITEHS.

IST=ttVLTI-FREQUENCY SA STATIC ANALYSIS N =HEITHER CS OR HS E =HARDHARE HODIFICATION REQ'D 7 BIAXIAL TESTING SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED flST=lfULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER CottPLETE SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION

'~

O______

SHOREHAH UNIT 1 RB LIST STONE & HEBSTE:t ENGINEE~ING CORPORATION Rt24 DATE 07/22/82 o" JOB NUl!ER 11600 3-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPHENT RUN TIME 14.19.26 LILCD DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (137 ITEMS) PAGE 2 ftARN EQUIPMENT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL q tufBER DESCRIPTION NO. RESP VEle0R ELEV INSP REPT HETH FREQ HTNG SHTDN STATUS 1R24EHCC1123 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CD SC113 YES 108-1.01-L2 HBT 4 F CS.HS H 3

1R24xHCC1124 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D C0 SC151 YES 108-1.01-L2 FET 4 F CS.HS H , 3

'IR24xHCC1127 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CO SC40 YES 108-1.01-L2 FET 4 F CS,HS H 1R24xtlCC1128 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SC113 YES 108-1.01-L2 HBT 4 F CS HS H 1R24aHCC1129 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SC40 YES 108-1.01-L2 teT 4 F CS,HS H IC24xt1CC1131 HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CD SC63 YES 108-1.01-L2 teT 4 F CS,HS H IR24xPit-B1 480 VAC CNT BHR 115 ED SQUARE D C0 SC112 YES 8998-10.09-L23 teT 20 F CS.HS H l IR24xPit-GI 480 VAC CNT BHR 115 ED SQUARE D CO SC112 YES 8998-10.09-L23 teT 20 F CS.HS H <q 1R24xPFL-R1 480 VAC CNT BHR 115 ED SQUARE D CD SC112 YES 8998-10.09-L23 HBT 20 F CS.HS H l s 1R24xPtL-R2 480 VAC CNT BHR 115 ED SQUARE D C0 SC112 YES 8995-30.09-L23 teT 20 F C3,HS H

)

1R24xPNL-Y1 480 VAC CNT BHR 115 ED SQUARE D C0 SC112 YES 8998-10.09-L23 teT 20 F CS HS H l

m. IR24xPPL-01 480 VAC CNT BHR 115 ED SQUARE D CO SC78 YES 8998-10.09-L23 teT 20 F CS,HS H 1R24xPFL-02 480 VAC CNT BHR 115 ED SQUARE D C0 SC78 YES 8998-10.09-L23 HBT 20 F CS.HS H 1R24xPNL-03 480 VAC CNT BHR 115 ED SQUARE D CD SC78 YES 8998-10.09-L23 HBT 20 F CS.HS H l

~)l 1R24rPtL-04 480 VAC CNTRL PHR FEED 115 ED SQUARE D CD SC112 YES 8998-10.09-L23 teT 20 F CS.HS H 1R35EPHL-B2 EHER 120 V PtL 82-SC 124 ED SYSTEH CONT SC112 YES 45322-1 HBT 15 F CS HS H ,

1R35xPit-R2 EHER 120 V Ptt R2-SC 124 ED SYSTEM CONT SC112 YES 45322-1 HBT 15 F CS.HS H 'l

- IT23sZ-001 REACTOR CONT ELEC PENE 134 ED GEN ELEC CD SC/PC YES F73414 SAT 24 F10 CS.HS F .

IR42s'fCC-0A1 125 VDC HOTOR CONT CEN 168 ED GEN ELEC SC40 YES 79GPC005 SAT 100 F CS.HS H 1R*,2tHCC-0A2 125 VDC HOTOR CONT CEN 168 GEN ELEC SC112 YES 79GPC005 ED SAT 100 F CS HS H

..)

_1R42aHCC-081 125 VDC HOTOR CONT CEN 168 ED GEN ELEC SC40 YES 79GPC005 SAT 100 F CS HS H CS = COLD SHUT DOHN P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 3 -JULY 1982 ~)

D : DUCT HOUNTED PC = PRIMARY CONT. BIAXIAL TESTING A = REEVALUATION C0tFLETE DA =DYNAHIC ANALYSIS PL = PEDESTAL SC = SECONDARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: IMIBER IN

- F = FLOOR HOUNTED QP = QUALIFIED BY / = LOCATED CH CONT. C =S/H REcotRIENDATION TO LILCO ' TYPE HTNG' COLUlti IS

') HS = HOT STANDBY PIPING ANALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEHS. )

1:ST=llVLTI-FREQUENCY SA = STATIC ANALYSIS N =NEITHER CS OR HS E =HARDHARE HDDIFICATION REQ'D 7 BIAXIAL TESTING SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED

, HST=HULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER COFPLETE SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION 00 - _ . _ _ _ _ _ _ ._ _

/

SHOREllAlf UttIT 1 RB LIST STONE & HE2. STER ENGINEERING CORPORATION JOB flUllDER 11600 RUN DATE 07/22/C2 3-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPitENT LILCO DOCHET 50-322 RUN TIlfE 14.19.26 ACTIVE BOP QUALIFICATION LEVEL (137 ITEllS) #m PAGE 3 4

ftARH EQUIPHENT SPEC DIV. BLOG AVAIL QUAL QUAL TYPE SAFE QUAL 3 tPJfEER DESCRIPTION NO. RESP VENDOR ELEV INSP REPT HETH FREQ HTNG SHTDN STATUS

-s IR42*lfCC-082 125 VDC HOTOR CoffT CEN 168 ED GEN ELEC SC112 YES 79GPC005 SAT 100 F CS.HS H s IB21 MRV 093 VAC RELIEF VALVES 175 PD AND. GRt8e PC YES TR-77-18 SAT 18 F12 N B 1G41mE-019 FUEL STG POOL HT EXCHA 190 PD STRUTHERS CO SC151 YES 70-06-30787 SA 25 F2 CS.HS H IP42aE-011 RBCLCN HT EXCHANGER 190 PD STRtfTHERS CO SC8 YES 70-06-30786 SA 12 F2 CS.HS H 3

l IPs2xE-117 BOOSTER HT EXCH 190 PD STRUTHERS SC8 YES 79-06-33475 SA 5+ F2 HS H i 1E21EP-049 LOOP LEVEL PUFPS 235 PD GOULD PUtr SC008 YES HE-320 SA 60+ F2 CS H i

j IE41tP-050 LOOP LEVEL PUtr 235 PD GOULD PUtr SC008 YES HE-320 SA 60+ F CS H

, 1E51KP-051 LOOP LEVEL PUtr 235 PD GOULD PUtr SC008 YES HE-320 SA 60+ F CS H g6 1R35mT-B2 XFHR-EttER 120 V PNL B2 248 ED HAGNETICS SC112 YES HYLE 43424-1 HBT 9 F CS.HS H -

1 s 1R35aT-R2 XFHR-EHER 120V PFL R2 248 ED HAGNETICS SC112 YES HYLE 43424-1 HBT 9 F CS,HS H t 3

IT46xFN-003 RB EXH FANS-RBNVS 270 PD BUFFALil FORGE SC124 YES 74S-11136 SA 15 F3 CS H IT46xCLC-05 RBSVS C00 Lits COILS 274 PO BUFFALO FORGE SC113 YES 80H-27781 5 SA F2 CS.HS H IT46sUC-002 UNIT COOLERS-RBSVS 276 PD BUFFALO FORGE SC8 YES 80N-27781 5 SA F2 CS.HS H 1T46sUC-003 UNIT COOLERS-RBSVS 276 PD BUFFALO FORGE SC008 YES 80N-27781 SA 5 CS,HS H s F2 ,

IT46mUC-004 UtlIT COOLERS-RBSVS 276 PD BUFFAi.O FORGE SC175 YES 80H-27781 5 SA F2 CS.HS H IT46xUC-005 UNIT COOLERS-RBSVS 276 PD BUFFALO FORGE SC175 YES 80N-27781 5 SA F2 CS.HS H

)

IT46KUC-020 UNIT COOLERS-HCC IN RB 276 PD BUFFALO FORGE SC112 YES 80H-27781 5 SA F2 CS.HS H IT46xOC-021 UNIT COOLERS 276 PD BUFFALO FORGE SC150 YES 80N-27781 SA 5 F2 CS HS H IT46tUC-022 UNIT COOLERS - RBSVS 276 PD BUFFALO FORGE SC161 YES 80ti-27781 5 SA F2 CS.HS H IT46mUC-023 UNIT COOLER HCC RB 276 PD BUFFALO FORGE SC040 YES 80H-27903-6 SA 5 F N H

-)

_1T48xPNL-48 HYD RECOHB P0HER CABIN 289 PD ATONICS INT SC112 YES 58083 FET 14 F2 N H CS = COLD SHUT DOHN P = PIPE HOUNTED SBT=5 INGLE FREQUENCY QUALIFICATION HILESTONES D : DUCT If0UHTED REVISIDH 3 -JULY 1982 PC =PRIHARY CONT. BIAXIAL TESTING A = REEVALUATION C0tFLETE DA =DYilAllIC ANALYSIS PL = PEDESTAL SC = SECONDARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: NUl!BER IN F = FLOOR HOUNTED QP = QUALIFIED BY / = LOCATED ON CONT. C =S/H REC 0lRIENDATION TO LILCD

' TYPE HTNG' COLUtM IS HS = HOT staff 0BY PIPING ANALYSIS HALL D = QUAL DOC RECEIVED '

QUANTITY OF ITEltS.

PET =lfULTI-FREQUENCY SA = STATIC ANALYSIS N =NEITHER CS OR HS E =HARDHARE HODIFICATION REQ'O I BIAXIAL TESTING SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED s HST=l1ULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER COHPLETE SIllGLE AXIAL TESTIts H = COPIES OF DOC TO DISTRIBUTION '

ta

SHOREHAM UNIT 1 RB LIST STONE & HEBSTE3 ENGINEERING CORPORATION RUN DATE 07/22/82

, JOB hut llliER 11600 3-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPHENT RUN TIttE 14.19.26 LILCD DOCHET 50-322 ALTIVE BOP QUALIFICATION LEVEL (137 ITENS) PAGE 4 '

HARH EQUIPHENT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL

, HUlBER DESCRIPTION HD. RESP VENDOR ELEV INSP REPT HETH FREQ ifTNG SilTDN STATUS IT48=RC-002 HYD REC 0tB UNIT 289 PD ATOHICS INT SC112 YES 54591-2 IBT 14 F2 N H

- IT46mA00040 RB REFUEL LVL EXHAUST 319 CD P0HERS REGLA. SC154 YES 44540-1 SA/ SAT 40 F2 CS H ,

'IT46*A00041 RB POT CONTAH AREA EXH 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 CS,HS H

, IT46*FT 004 RBSVS EXH AIR FLOM 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 N H IT46*HE 002 FLT-1 HOISTURE 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 N H IT46mH00031 RBSVS ItLET TO HIX PLH 319 . CD P0HERS REGUL SC135 YES 43812-1 SA/ SAT 24 F2 CS,HS H

-3 IT46*H00034 RBSVS FILTER TRAIN DCH 319 CD P0HERS REGUL SC182 YES 44540-1 SA/ SAT 40 F2 CS H

,S IT46*H00036 FN-3 DISCHARGE AIR 319 CD P0HERS REGUL SC126 YES 43812-1 SA/ SAT 24 F3 CS,HS H 1-I IT46mH00047 Fti-79 DISCHARGE AIR 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 N H IT46ml100048 FLT-1 ItLET AIR 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 N H

)

) 1T46*PDS045 FN-3 DIFF PRESSURE 319 CD P0HERS REGLA. SC112 YES 43812-1 SA/ SAT 24 F2 CS.HS H IT46mPDSO46 FN-3 DIFF PRESSURE 319 CD P0HERS REGUL SC112 YES 43812-1 SA/ SAT 24 F3 C3eHS H q 1011tPtLO61 CON DH HON 332 PD iflC SC112 YES 45493-1 HBT 12 F N H

, IT48xPit-68 GAS ANALYZER-DRYMELL 344 PD DELPHI ItB SC112 YES 1035-1 IBT 18 F2 N H 1T481PNL-69

)

GAS ANALYZER-SUPPR CHH 344 PD DELPHI ItB SC112 YES 1035-1 HBT 18 F2 N H IP42*PS 021 PUIP IP42=P005C DISCH 348 ED ASCO SC153 YES 178 SAT 60+ F3 HS G IP42aPS 022 PUHP 1P42mP005B DISCH 348 ED ASCO SC153 YES 178 SAT 60+ F3 HS G j IP42*PS 046 PUtr IP42mP005A DISCH 348 ED ASCO SC151 YES 178 SAT 60+ F3 HS G q

l IP50rPS 105 SERV AIR HDR PRESS 348 ED ASCO SC102 178 SAT 60+ F2 CS,HS G IP50xPS 113 SERV AIR HDR NORH SUP 348 ED ASCO SC102 178 SAT 60+ F2 CS,HS G

_ 1B21tPT 153 RV092 HONITOR 406 CD ROSEHOUNT SC040 YES 127516 fBT 60+ F11 CS HS G h CS = COLD SHUT DOHN P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 3 -JULY 1982 #)

D = DUCT HOUNTED PC :PRIHARY CONT. BIAXIAL TESTING A = REEVALUATION C0tFLETE DA :DYNAHIC ANALYSIS PL : PEDESTAL SC = SECONDARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: NUMBER IN F = FLOOR If0UNTED QP = QUALIFIED BY / = LOCATED ON CONT. C =S/H REC 0ttfENDATION TO LILCO ' TYPE HTNG' COLUHH IS HS = HOT STANDBY GT=HULTI-FREQUENCY PIPING ANALYSIS SA = STATIC ANALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF I1 Ells. I),.

H =HEITHER CS OR HS E =HARDHARE HODIFICATION REQ'O I BIAXIAL TESTING SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED

,. IIST=HULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER C0tPLETE f ) SINGLE AXIAL TESTING H = COPIES OF DOC TD DISTRIBUTION )

i,

f SHOREHAH UNIT 1 RB LIST STONE & HEBSTER EFEINEERING CORPORATION JOB NUtHER 11600 RUN DATE 07/22/62 3-SORT REI.CTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPHENT LILCO DOCHET 50-322 RUN TIHE 14.19.26 ACTIVE BOP QUALIFICATION LEVEL (137 ITEHS) PAGE 5 ftARN EQUIPHENT SPEC DIV. BLOG AVAIL QUAL QUAL TYPE SAFE QUAL

-~ HUHBER DESCRIPTION NO. RESP VENDOR ELEV INSP REPT 7

HETH FREQ HTNG SHTON STATUS p 1821=TE 147 HST PA STEAM LH DET 406 CD ROSEHOUNT SC078 YES 2767 SAT 60+ F2 CS.HS G

IC61mLT 026 $UPP POOL 906 CD ROSEHOUNT SC008 YES 127516 HDT 60+ F CS.HS G IC61mPT 012 DRYHELL PRESS 406 CD ROSEHOUNT SC098 YES 127516 60+

HBT F CS.HS G l - IC61wPT 106 SAFETY REL VALVE 406 CD ROSEHOUNT SC101 YES 127516 HBT 60+ F CS.HS G IC61mTE 021 DRYHELL TEFF 436 CD ROSEHOUNT SC150 YES 2767 SAT 60+ F CS HS F

,3 1C61mTE 022 SUPP POOL TEtP 406 CD ROSEHOUNT SC028 YES 2767 SAT 60+ F2 CS HS F IE41=PT 142 TO LUBE OIL COOLER 406 CD ROSEHOUNT SC8 YES 127516 60+

HBT F CS.HS G

~

IE51ePT 142 TO LUBE OIL COOLER 406 CD ROSEHOUNT SC8 YES 127516 PET 60+ F CS,HS G IG11mFT 647 SUPP POOL Pt#F BACM 406 CD ROSEHOUNT SC006 YES 127516 HBT 60+ F3 CS,HS G IP41mFT 146 PBCLCH HX SERV HATER 406 CD ROSEHOUNT SC024 YES 127516 HBT 60+ F2 CS HS G -.

IP41*FT 151 RAD HON SAIPLE 406 CD ROSEHOUNT SC006 YES 127516 HBT 60+ F2 CS,HS G IP50*PT 111 ADS ACCUHULATOR 406 CD ROSEHOUNT SC101 YES 127514 60+

HBT F2 CS.HS G s

IP50mPT 116 SERV AIR HDR PRESS 406 CD ROSEHOUNT SC101 YES 127516 HBT 60+ F2 CS,HS G r IT46aPDT003 FLT-1A DIFF PRESSURE 406 CD ROSEHOUNT SC112 YES 127516 HBT 60+ F2 CS,HS G ,

! 1T46mPDT043 REACTOR BLDG DIFF 406 CD ROSEHOL#fT SC220 YES 127516 MBT 60+ F2 CS HS G i

1TC6mTE 001 RBSVS RECIRC AIR TEFF 406 CD ROSEHOUNT SC144 YES 2747 SAT 60+ F2 CS.HS G ,

IT46mTE 022 AIR RETURN TO UC-2 406 CD ROSEHOUNT SC10 YES 2747 60+

SAT F2 CS.HS G IT46mTE 023 AIR RETURN TO UC-3 406 CD ROSEHOUNT SC42 YES 2767 SAT 60+ F2 CS.HS G IT46mTE 024 AIR RETURN TO UC-4 406 CD ROSEHOUNT SC220 YES 2767 SAT 60+ F2 CS.HS G s IT46mTE 025 AIR RETURN TO UC-5 406 CD ROSEHOUNT SC220 YES 2767 60+

SAT F2 CS.HS G . .

_ 1T46mTE 028 HCC RH UNIT COOLER 406 CD ROSEHOUNT SC128 YES 2767 SAT 60+ F2 CS,HS G CS = COLD SHUT DOHN P : PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 3 -JULY 1982 D : DUCT tt0UNTED PC :PRIHARY CONT. BIAXIAL TESTING A = REEVALUATION CDHPLETE DA :DYNAHIC ANALYSIS PL : PEDESTAL SC zSECONDARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: NUtIDER IN F : FLOOR lt0UNTED GP = QUALIFIED BY / = LOCATED ON CONT. C =S/M REcoltfENDATION TO LILCO ' TYPE HTNG' COLUltf IS tis : HOT STANDBY PIPING ANALYSIS HALL D = QUAL DOC RECEIVED I QUANTITY OF ITEttS.

~ 12T:ltULTI-FREQUENCY SA = STATIC ANALYSIS H =NEITHER CS OR HS E =HARDHARE HODIFICATION REQ'D BIAXIAL TESTING SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED HST:ltULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER C0tFLETE SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTIDH '

15

SHOREHMt UNIT 1 RB LIST STONE & HEBSTE3 ENGINEERING CORPORATION RUN D*.TE 07/22/82

, JOB flUIEER 11600 3-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPHENT RUN TIttE 14.19.26 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (137 ITEHS) PAGE 6 HARH EQUIPHENT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL flutfBER DESCRIPTION NO. RESP VENDOR ELEV INSP REPT HETH FREQ ffTifG SHTON STATUS -s IT46mTE 059 wUC-21 UNIT CLR 406 CD ROSEHOUNT SC155 YES 2767 SAT 60+ F2 CS.HS G IT46mTE 060 wUC-22 UNIT CLR 406 CD ROSEHOUNT SC160 YES 2767 SAT 60+ F2 CS.HS G ITC8mFT 005N HEPA FILTER ItLET 406 CD ROSEHOUNT SC113 YES 127516 60+

SAT F2 CS.HS G 1Z93eLT 001 SUPPRESSIDH POOL LEVEL 406 CD ROSEHOUNT SC8 YES 127516 SAT 60+ F2 CS HS G ,

1Z93=PT 003 DRYHELL PRESSURE 406 CD ROSEHOUNT SC98 YES 100025 HBT 60+ F2 CS.HS G 1Z93*PT 004 SUPP POOL PRESS 406 CD ROSEHOWIT SC40 YES 108025 HBT 60+ F2 CS.HS G IZ93 ATE 110 RV092ACL DISCHARGE-IFT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F4 H F IZ93mTE 111 RV092BDE DISCHARGE-1FT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F4 H F IZ93eTE 112 RV092FG DISCHARGE-IFT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F4 H F

IZ93nTE 113 RV092FHJ DISCHARGE-IFT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F4 H F qj IZ93sTE 132 RV092ACL DISCHARGE-2FT 906 CD ROSEHOUNT PL28 2767 SAT 60+ F2 N F

!c IZ93nTE 133 RV092BDE DISCHARGE-2FT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F2 H F  ;

1Z93mTE 134 RV092HG DISCHARGE-2FT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F2 N F

,- IZ93nTE 135 RV092FHJ DISCHARGE-2FT 406 CD ROSEHOUNT PL28 2767 SAT 60+ F2 N F q

IP42rLS 012 RBCLCH TM-026 407 CD HAGNETROL SC160 YES 43235-1 IBT 17 F2 HS G IP42tLS 013 RBCLCH TH-026 407 CD HAGNETROL SC160 YES 43235-1 HBT 17 F2 HS G 3, IT481LS 061 COND LEVEL 407 CD HAGNETROL SC73 YES 43235-1 HBT 17 F2 HS G s

IF16tRAH-22 HI DENSITY SPNT FUEL R 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F29 N G q IF16xRAH-23 PERH CR STOR RACHS 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F H G 1F16tRAH-24 TEffP CR STOR RACHS 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F2 N G ,-)

_1R24aTRS111X LCPI ATS 438 ED ASCO SC112 YES 14606 HBT 13 F CS.HS H CS = COLD SHUT DollH P = PIPE ff0VNTED SBT= SINGLE FRFQUENCY QUALIFICATION HILESTONES REVISION 3 -JULY 1982 I D = DUCT HOUNTED PC =PRIHARY C0 tit. BIAXIAL TESTING A = REEVALUATION C0lFLETE 03 :DYNAIIIC ANALYSIS PL = PEDESTAL SC = SECONDARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: NU!!BER IN

-. F = FLOOR ff0UtiTED QP = QUALIFIED BY / = LOCATED ON CONT. C =S/H REC 0lRIENDATION TO LILCO ' TYPE IITifG' COLUMN IS -

HS = HOT STANOBY PIPING ANALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEllS.

13T=lfULTI-FREQUENCY SA

  • STATIC ANALYSIS H =NEITHER CS OR HS E =HARDHARE HODIFICATION REQ'D I BIAXIAL TESTING SAT = SINGLE FREQUEllCY F = QUAL DOC APVD & FILED llST=lfULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER COfIPLETE SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION I

'8 . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

i SHOREHAtt UNIT 1 RB LIST STONE & HEBSTER ENGINEEWIts CORPORATION RUN DATE 07/22/82 3' JOB nut"lER 11600 3-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPHENT RUN TIHE 14.19.26

, LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (137 ITEftS) PAGE 7 i

HARM EQUIPHENT SPEC DIV. BLOG AVAIL QUAL TYPE,

' QUAL SAFE QUAL nut 1BER DESCRIPTION NO. RESP VErm0R ELEV ITISP REPT HETH FREQ HTts SHTDN STATUS ,

1R24mTRS112Y LCPI ATS 438 ED ASCO SC112 YES 14606 HBT 13 F' CS.HS H 1R24=tIG-111 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES HE698 SA 27 F N H 3 1R24=ttG-112 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES HE698 SA 27 F N H 1R24*lfG-113 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES HE698 SA 27 F2 N H 3 1R24mPtL-111 LPCI SIP Ptt 439 ED LOUIS ALLIS SC150 84-66829 HBT 27 F N B l- 1R24mPill-112 LPCI SIP PFL 439 ED LOUIS ALLIS SC150 84-66829 HBT 27 F M B y IR24mPIL-113 LPCI SIP PtL 439 ED LOUIS ALLIS SC150 84-66829 HBT 27 F2 N B jg IB21mQEH001 HS SRV QNCHRS 447 PD SARGENT PC008 YES R-S-10078000 DA 9 F11 CS.HS G ,.)

IG11=LE 642 RB FLOOR LEVEL 473 CD DELAVAL SC008 DA F B IG11=LE 645 RB FLOOD LEVEL 473 CD DELAVAL SC008 YES SAT F4 8 y

ID21mRE 085 RAD HONITOR 475 CD HAHAM PC074 F2 B 3 ,
.

'Q ,- .

)

i (3

~

, )-

l.'

CS = COLD SHUT DOHN P = PIPE HOUNTED D : DUCT If00HTED PC :PRIHA8tY CONT.

SBT= SINGLE FREQUENCY BIAXIAL TESTING QUALIFICATION HILESTONES REVISION 3 -JULY 1982 -)

A = REEVALUATION ColFLETE DA :DYNAllIC AtIALYSIS PL : PEDESTAL SC =SEC0 TEARY CONT. B = REQUEST FOR QUAL OR BID ISSUED NOTE: NUttBER IN F = FLOOR HOUNTED QP = QUALIFIED BY / = LOCATED ON CONT. C =S/H REC 0ttfENDATIDH TO LILCO ' TYPE HTIE' COLUHH IS

~

HS = HOT STANDBY IL1T=HULTI-FREQUENCY PIPING ANALYSIS SA = STATIC ANALYSIS HALL M =HEITHER CS OR HS D =0UAL DOC RECEIVED E =HARDHARE HODIFICATION REQ'D QUANTITY OF ITEHS. O:

BIAXIAL TESTING SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED g HST=l!ULTI-FREQUENCY SINGLE AXIAL TESTING G =SQRT PAPER CotPLETE SINGLE AXIAL TESTING H = COPIES OF DOC TO DISTRIBUTION O' 3

~

t t4

SHOREHAff UtlIT 1 C3 LIST STotlE & IIEBSTER EtIGIllEERIllG CORPORATIOtt I

JOB tlUt2ER 11600 3-SORT RUtl DATE 07/22/82 CONTROL BUILDING CATEGORY I EQUIPitEtlT RUti TIHE 14.19.23 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL 1210 ITEllS) PAGE 1 itARN EQUIPifENT SPEC DIV.

i BLDG AVAIL QUAL QUAL TYPE SAFE QUAL tlUttBER DESCRIP TI0tt if0. RESP VFtOOR ELEV ItiSP REPT ltETH FREQ llillG SitTDil STATUS 1R22*SilG-101 4.16HV EltER BUS 101 39 ED GEt; CLEC CD 025 YES 300-91059 DA/ SAT 8 F CS ells H 1R22*SilG-102 4.16HV EttER BUS 102 39 ED GEH ELEC CD 025 YES 300-91059 DA/ SAT 8 F CS its H

+

  • 1R22*SHG-103 4.16HV Et1ER BUS 103 39 ED GEtt ELEC CD 025 YES 300-91059 DA/ SAT 8 F CS.HS H IX41sDitPF FIRE DAIFERS 54 PD AIR BALAtlCE 044 YES AB1-SH-009 SAT 9+ F30 CS.IIS 11 IX61mDIFF FIRE DAttPERS 54 PD AIR DALAtlCE 063 YES AB1-SH-009 SAT 9+ F8 CS.IIS 11 11tS0mP-137 RBSVS & CRAC CH PUltPS 62G PD GOULD PU!IPS 063 YES HE-326 SA 81 F2 CS.HS H lil50eP-138 RBSVS & CRAC CH PUttPS 62G PD GOULD PUlFS 063 YES IIE-326 SA 81 F2 CS.HS H llI50eP-139 RBSVS & CRAC C0 TID PUIP 62H PD HORTHINGT0tl 063 YES DHA-000047 SA 31 F2 CS.HS H ll150xP-140 RBSVS & CRAC C0tB PUIP 62H PD HORTHINGTON 063 YES DHA-000047 SA 31 F2 CS,HS H ltillalt0V031 2ic STAGE REHEAT STil 88V PD VELAtt 051 YES SR-6262 SA/ SAT 33+ P2 HS H 1H11stt0V036 11ISC STil FROH HOR ISO 88V PD VELAtl 051 YES SR-6262 SA/ SAT 33+ P HS H lil11st t0V041 AUXILIARY STEAtt SUPPLY 08V PD VELArt 051 YES SR-6181 SA/ SAT 33+ P CS 11 1R43sG-101 EllER DIESEL GEllERATOR 89 ED DE LAVAL 025 YES 11001 DA 4 FIS CS.HS H 1R43mG-102 EMER DIESEL GEtlERATOR 89 ED DE LAVAL 025 YES 11001 SAT 4 F18 CS HS II 1R43sG-103 EllER DIESEL GEllERATOR 89 ED DE LAVAL 025 YES 11001 SAT 4 F18 CS.HS li 1R23sSHG-111 480V EllER SHGR BUS 111 95 ED ITE 025 33-48359 YES IBT 5 F CS.HS H 1R23mSHG-112 480V EttER SIIGR BUS 112 95 ED ITE 025 YES 33-48359 11DT 5 F CS .Ils H 1R23sSl!G-113 480V EttER SHGR BUS 113 95 ED ITE 025 YES 33-48359 itBT 5 F CS .itS H 1R23mT-101 4160-480V TRAtlSF BUS 1 95 ED ITE 025 YES 33-48359 ilBT 6 F CS.IIS H 1R23aT-102 4160-400V TRANSF BUS 1 95 ED ITE 025 YES 33-48359  !!BT 6 F CS ells 11

_1R23nT-103 4160-400V TRAt4S BUS 11 95 ED ITE 025 YES 33-48359 11BT 6 F CS elfS H CS = COLD SHUT DOHtt P = PIPE It0UtlTED SBT=SIllGLE FREQUEllCY CUALIFICATION llILESTotlES REVISI0tl 3 -JULY 1982 DA :DYHAllIC AtlALYSIS

  • TEST ARTICLE BIAXIAL TESTIrlG A =REEVALUATI0tl C0ftPLETE F = FLOOR ll0UllTED B = REQUEST FOR QUAL OR BID ISSUED HOTE HUtt0ER Ill 113 = HOT STAtIDBY QP = QUALIFIED BY H =HEITHER CS OR HS C =S/H REC 0ll!!Et!DATIOil TO LILCO ' TYPE ftTilG' COLUttN IS ltBT=ltVLTI-FREQUEtlCY PIPItlG AtlALYSIS D = QUAL DOC RECEIVED BIAXIAL TESTING QUAtlTITY OF ITEllS.

SA = STATIC AtlALYSIS E =HARDHARE It001FICATI0tl REQ'D TitST=ttULTI-FREQUENCY SAT =SIrlGLE FREQUEtlCY F = QUAL DOC APVD 1 FILED SIllGLE AXIAL TESTING SItIGLE AXIAL TESTItlG G =SQRT PAPER COllPLETE H = COPIES OF DOC TO DISTRIBUTI0tt

SHOREHAH UtlIT 1 C") LIST ST0tlE & HEBSTER EtiCINEERIIG CORPORATION RUti DATE 07/22/82 JOB #1UtfBER 11600 3-50RT C0tITROL BUILDItG CATEGORY I EQUIFitEtiT RUti TIttE 14.19.23 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (210 ITEttS) PAGE 2

!! ARM EQUIPitENT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL ITJttDER DESCRIPTI0tl NO. RESP VEtEOR ELEV INSP REPT ltETH FREQ ftTIG SHTDil STATUS 1R42mSHG-Al 125 VDC SilG BATTERY BU 95 ED ITE 025 YES 33-51266 ftBT 5 F CS,HS H 1R42mSHG-B1 125 VDC SHG BATTERY BU 95 ED ITE 025 YES 33-51266 ttBT 5 F CS IIS H IP42mSlIG-C1 125 VDC SHG BATTERY BU 95 ED ITE 025 YES 33-51266  !!BT 5 F CS.HS H

}

IX61=FH-025 CONTROL R00tl BOOSTER F 102 PD BUFFALO FORGE 063 YES 745-4234A SA 27 FZ CS HS H IX61mFLT-02 CRAC FILTER TRAltlS 105 PD FARR CD 063 YES D-56302 SA/ SAT 17 F2 CS.HS H lil50ertiL-03 CHILLER CONTROL PAtlEL 106 PD TRAtlE CO 063 YES HUC-102 SA 13 F2 CS,HS H lil50=Pf1L-04 CHILLER CONTROL PAtlEL 106 PD TRANE 063 YES tlUC-102 SA 13 F2 CS.HS H ll!50allC-003 RBSVS & CRAC HTR CHILL 106 PD TRANE CD 063 YES HUC-102 SA 31 F2 CS,HS H lits 0 stlC-004 RBSVS & CRAC HTR CHOLL 106 PD TRAtlE CO 063 YES NUC-102 SA 31 F2 CS.HS H l IX61=A0V036 CHTRL RH ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 17+ P2 CS H IX61sA0V038 CNTRL RH ISOL 111 PD FISHER 073 YES CD75-35 SA/ SAT 21 P2 CS H I

IX61mA0V039 CHTRL Rif ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 21 P2 CS H IX61stf0V031 CHTRL Rif ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 22+ P2 CS H IX61stf0V032 CNTRL Rif ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 22+ P2 CS H l Ilt50mTM-088 RBSVS & CRAC-SURGE TAN 114 PD BUFFALO TAllK 063 YES t#1(BI-122-IA SA 45 F2 CS.HS H 1R43sTM-135 FUEL OIL DAY 114 PD BUFFALO TANN 044 YES teH B I-134-I A SA 27 F3 CS H 1R24xttCC1115 ff0 TOR C0 tit CNTR, BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 HBT 4 F CS.HS H 1R24sttCC1116 fl0TCR CONT CNTR, BUS 1 115 ED SQUARE D CD 025 YES 108-1.01 L2 IET 4 F CS.HS H 1R24stfCC1125 It0 TOR CONT CitTR, BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 HDT 4 F CS.HS H 1R24xitCC1126 IIOTOR CONT CliTR, BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 ItBT 4 F CS.HS H

_ 1R24ritCC1133 ft0 TOR CONT CNTR, BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 ItDT 4 F CS.HS H CS = COLD SHUT DOHN P = PIPE HOUNTED SBT=SIrlGLE FREQUErlCY QUALIFICATION HILEST0ffES REVISION 3 -JULY 1982 DA :DYHAtlIC ANALYSIS

  • TEST ARTICLE BIAXIAL TESTING A =REEVALUATIcti CottPLETE F = FLOOR ff0VHTED B = REQUEST FOR QUAL OR BID ISSUED ff0TE3 flUtt0ER IN HS = HOT STAtlDBY QP = QUALIFIED BY H =HEITHER CS OR HS C =S/H REC 0ttitENDATION TO LILCO '1YPE IITitG' COLutti IS f TDT =lfULTI-FREQUEt4CY PIPIT 4G ANALYSIS D = QUAL DOC RECEIVED QUANTITY OF ITEllS.

BIAXIAL TESTIrlG SA = STATIC ANALYSIS E =HARDHARE HODIFICATION REQ'D -

CitST=lfULTI-FREQUENCY SAT = SINGLE FREQUEllCY F = QUAL DOC APVD & FILED SIllGLE AXIAL TESTIllG SINGLE AXIAL TESTIllG G =SQRT PAPER CollPLETE H = COPIES OF DOC TO DISTRIBUTION

SHOREHAtt UNIT 1 CB LIST ST0tlE & HEBSTER EtlCItIEERItfG CORPORATIOrt JOB IIUtmER 11600 3-SORT RUtf DATE 07/22/02 C0tlTROL BUILDItfG CATEGORY I EQUIPitENT RUtl tit 1E 14.19.23 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (210 ITEffS) PAGE 3 ftAPH EQUIPifEtiT SPEC DIV. BLOG AVAIL QUAL QUAL TYPE SAFE QUAL NUtfDER DESCRIPTION tio. RESP VENDOR ELEV It4SP REPT  !!ETH FREQ IITilG SHTDil STATUS 1R24stICC1134 ff0 TOR C0 tit CHTR, BUS 1 115 ED SQUARE D CO 025 108-1.01 L2 YES IBT 4 F CS ells H 1R42=BA-Al 125 VOLT BATTERY 116 ED GOULD IllC 025 YES 42795 IIDT 40+ F CS.HS 11 1R42mDA-B1 125 VOLT BATTERY 116 ED GOULD Ilic 025 YES 42795 IET 40+ F CS.HS H 1R42.DA-C1 125 VOLT BATTERY 116 ED GOULD IllC 025 YES 42795 Imi 40+ F CSittS H 1R42*BC-Al 125 VOLT BATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT 8 F CS.HS 11 IR42mBC-D1 125 VOLT BATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT 8 F CS.HS H IPC2nBC-C1 125 VOLT DATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT 8 F CSillS H lil11stfCB-01 f tAIta C0t1 TROL BOARD 120 CD RELIAt4CE 063 YES 43331-1 SA/ttST 16 F C3.HS 11 1R35=PtL-B1 EttER 120V PtL B1-REL R 124 ED SYSTEll CONT 044 YES 15074 SAT 21 F CS.HS H 1R35ePiL-B3 ElfER 120/240V PAtlEL 124 ED SYSTEH C0 tit 020 YES 15074 SAT 21 F CS.HS H 1R35=PtL-R1 ElfER 120V Ptil R1-REL R 124 ED SYSTEH COffT 044 YES 15074 SAT 21 F CS HS H 1R35=PHL-R3 EllER 120/240V PAtlEL 124 ED SYSTEH CONT 020 YES 15074 SAT 21 F CS.HS H 1R35xPtL-01 E!!ER 120V PflL 01-REL R 124 ED SYSTEli C0 tit 044 YES 15074 SAT 21 F CS.HS H 1R35tPtL-02 EltER 120/240V PAHEL 124 ED SYSTEH CoffT 020 YES 15074 SAT 21 F CS,HS H 1R42nrtL-Al 125 VDC DIST PAtlEL BUS 124 ED SYSTEH CONT 025 YES 15074 SAT 21 F CS.HS 11

/

1R42xPfL-AZ 125 VDC DIST PAtIEL BUS 124 ED SYSTEH CONT 044 YES 15074 SAT 21 F CS,HS H 1R42artL-B1 125 VDC DIST PAf1EL BUS 124 ED SYSTEH CONT 025 YES 15074 SAT 21 F CS.HS H 1 42sPflL-D2 125 VDC DIST PAtlEL BUS 124 ED SYSTEll C0 tit 044 YES 15074w SAT 21 F CS.HS H 1R42nPtL-C1 125 VDC DIST PAtiEL BUS 124 ED SYSTEll C0 TIT 025 YES 15074 SAT 21 F CS.HS H 1R42cPFL-C4 125 VDC DST PtL-BLH-BS 124 ED SYSTEH C0 tit 025 YES 15074 SAT 21 F CS.HS H

_1H11 spit-AC1 112102 AtlAltPST ACC SAtt 125 CD RELIANCE 063 RCAP-001-0 SA 13 F CS B CS = COLD SilUT DOHN P = PIPE ffoUtiTED SDT=SIllGLE FREQUEtICY QUALIFICATI0tl HILEST0tlES DA =DYilAtlIC AtlALYSIS REVISI0tt 3 -JULY 1982 w TEST ARTICLE DIAXIAL TESTIllG A =REEW1UATION C011PLETE F = FLOOR ItOUNTED HS = HOT STAtIDBY B = REQUEST FOR QUAL OR BID ISSUED ff0TE: fluf fDER Iti QP = QUALIFIED BY H =HEITHER CS OR HS C =S/H REC 0tlHEtIDATION TO LILCO ' TYPE IITitG' COLUtIN IS IfBT=tIULTI-FREQUENCY PIPINS AffALYSIS D = QUAL DOC RECEIVED BIAXIAL TESTItG QUANTITY OF ITEttS.

SA = STATIC AtlALYSIS E =HARDilARE IIODIFICATION REQ'D Tit 3T:lfULTI-FREQUEilCY SAT = SINGLE FREQUEtiCY F = QUAL DOC APVD & FILED SIriCLE AXIAL TESTING SINGLE AXIAL TESTING G =SQRT PAPER C0f tPLETE H = COPIES OF DOC TO DISTRIDUTION 4 -

Elf 0REllAff UttIT 1 CB LIST STollE & HEBSTER EtiGINEERIllG CORPORATIOtt JOB llUMDER 11600 3-30RT RUlf DATE 07/22/82 C0flTROL BUILDIt1G CATEGORY I EQUIrllENT RUti tit 1E 14.19.23 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0ti LEVEL (210 ITEttS) PAGE 4 llARM EQUIPitElli SPEC DIV. BLDG AVAIL QUAL QUAL TYPE tlUt!BER SAFE QUAL DESCRIPTION H3. RESP vet 00R ELEV IllSP REPT ltETH FREQ llTilG SHTDH STATUS 1H11=PtL-AC2 H2102 AtlALAPST ACC SAff 125 CD RELIAtlCE 063 RCAP-001-0 SA 13 F ,

CS B 1H11=PIL-DR1 BUFFER RELAY CAS 125 CD RELIANCE 044 YES 99AX400536 SA/llST 37 F CS ells B IH11 writ-itXP ltISC CONTROL PANEL 125 CD RELIAtlCE 063 YES 99AX400590 SA/llST 17 F CS HS B 1H11wrtL-PCll PRI COHT ff0tIITOR PAtlEL 125 CD RELIAffCE 063 YES 99AX400666 SA/itST 14 F ti B lilllwrit-VC1 TB & ItISC VElli 125 CD RELIAtEE 063 YES 99AX400536 SA/ItST 17 F CS B IH11'*PtL-VC2 RB VEtiT 125 CD RELIAtlCE 063 YES 99AX400536 SA/IIST 17 F CS B 1H21mPtL-AX1 AUX RELAY 125 CD RELIAttCE 044 99AX400590 YES SA/itST 32 F CS ells B lil21 =PtL- AX2 AUX RELAY 125 CD RELIAtlCE 044 YES 99AX400590 SA/ftST 32 F CS HS B 1H21 PtfL-AX3 AUX RELAY PANEL AX3 125 CD RELIANCE 063 YES AAI-131 SA/HST 22 F CS,HS B 1H21* Pit-AX5 AUX RELAY PANEL AX5 125 CD RELIAtlCE 063 YES AAI-131 SA/ItST 22 F CS ells B lil21oPit-AX6 AUX RELAY PAtlEL AX6 125 CD RELIANCE 063 YES AAI-131 SA/ftST 22 F CS.HS B 1H21mPIL-VX1 VEFIT AUX RELAY 125 CD RELIAtlCE 044 YES 99AXO536-VX1 SA/IIST 34 F CS ells B 1H21 =PIL-VX2 VElli AUX RELAY 125 CD RELIAtlCE 044 YES 99AX0536-VX1 SA/llST CS,HS 34 F 8 IH21*PtL-VX3 VEtiT AUX RELAY 125 CD RELIANCE 044 YES 99AX0536-VX1 SA/ttST 23 F CS ells B 1H21mPFL-060 ELEC ANAL IllSTR RM 125 CD RELIANCE 044 YES 99AX400679 SA/llST 33 F CS HS H 1R23mPit-001 480V LOAD RESET PAtlEll 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F CS,HS B 1R23mrtL-002 400V LOAD RESET PANEL 2 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F CS HS B IR23mPIL-003 400V LOAD RESET PANEL 3 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F CS,HS B IT48 vPIL- ACH PC ATit CNTRL 125 CD RELIAtlCE 063 YES 99AX400600 SA/ SAT 19 F tl B 1Z95aEllCSX1 SXS EtlCLOSURE 125 CD RELIAtlCE 044 99AX400827 SA 61 F B

_1Z95xEffCSX2 SXS EllCLOSURE 125 CD RELIAtlCE 044 99AX400827 SA 61 F B CS = COLD SliUT DOHN P = PIPE HOUNTED SBT=SIllGLE FREQUEllCY QUALIFICATI0tl itILEST0tlES REVISIOtt 3 -JULY 1982 DA =0YllA111C AtlALYSIS

  • TEST ARTICLE BIAXIAL TESTIt4G A = REEVALUATION C0!IPLETE F =FLOCR ff0UllTED B = REQUEST FOR QUAL OR BID ISSUED if0TE: NUlfDER IN lts = HOT STAffDBY QP = QUALIFIED BY H =NEITHER CS OR HS C =S/H REC 0ttittIDATION TO LILCO ' TYPE ItTNG' COLUltH IS I!DT=lfULTI-FREQUEtlCY PIPING AllALYSIS D =OUAL DOC RECEIVED QUAtlTITY OF ITEtts.

EIAXIAL TESTIttG SA = STATIC AtlALYSIS E =HARDilARE H0DIFICATI0tl REQ'D TitST=ttVLTI-FREQUEHCY SAT = SINGLE FREQUENCY F = QUAL DOC APVD & FILED S1HGLE AXIAL TESTIllG SItlGLE AXIAL TESTING G =SQRT PAPER C0llPLETE H = COPIES CF DOC TO DISTRIBUTI0fl

SHOREllAtt IIIIT 1 C3 LIST ST0tlE & HECSTER EllGIrlEERIrlG CORPORATI0tt JC3 tlUttDER 11600 RUH DATE 07/22/82 3-SORT C0tiTROL BUILDItIG CATEGORY I EQUIPtfEtiT LILCO DOCHET 50-322 ACTIVE RUti TIttE 14.19.23 BOP QUALIFICATI0ff LEVEL (210 ITEllS) PAGE 5 ftARH EQUIFt!EllT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL tlUtIBER DESCRIPTI0tl fl0. RESP VENDOR ELEV INSP REPT ltETH FREQ llTilG SitTDil STATUS IZ95eEllCSX3 SXS EtlCLOSURE 125 CD RELIAtlCE 044 99AX400827 SA 61 F B IZ95mEllCSX4 SXS EtlCLOSURE 125 CD RELIAllCE 044 99AX400827 SA 61 F B 1297aPflLERI IIULTIPLEX CAD 125 CD RELIAtEE 044 99AX401437 SA 14 F B IZ97mPilLER2 ftVLTIPLEX CAB 125 CD RELIAtlCE 044 4

99AX401437 SA 14 F B l 1Z97prtLER3 ffULTIPLEX CAB 125 CD RELIAtlCEV 044 99AX401437 SA 14 F B IP41 MRV 064 CifTRL Rt! & RBSVS HC-3 191 CD L0tlERGAN 076 YES 502644 SA 60 P2 HS G IP41=RV 065 CNTRL RH & RBSVS HC-4B 191 CD LONERGAN 076 YES 502644 SA 60 P2 HS G lits 0 =t t0V031 CH RETURN 197 PD PRATT 071 YES D-0034-7 SA 394 P2 CS.HS H lt!5Catt0V032 CH SUPPLY 197 PD PRATT 075 YES D-0034-7 SA 394 P2 CS.HS H lil50stt0V033 CH RETURif CROSSOVER 197 PD PRATT 071 YES D-0034-7 SA 394 P2 CS.HS H lit 30mit0V034 CH SUPPLY CROSSOVER 197 PD PRATT 075 YES D-0034-7 SA 394 P2 CS.HS H IP41mfl0V036A VT' CHILL HTR SPLY ISOL 197 PD PRATT 012 YES D-0034-3 SA 33+ P CS.HS H IP41wtt0V036B VT CHILL HTR SPLY ISOL 197 PD PRATT 012 YES D-0034-3 SA 33+ P CS.HS H IP41stt0V036C VT CHILL HTR SPLY ISOL 197 PD PRATT 050 YES D-0034-4 SA 297 P CS.HS H lil43mPIL-C01 CO2 DETEC PtL RELAY R1 238 PD RELIAtlCE 044 YES 44204-1 fBT 17 F2 H H It!43tPril-C02 CO2 SUPVR PtL BATTERY 238 PD RELIANCE 025 YES 44204-1 ItBT 17 F H H lll43tPHL-C03 CO2 SUPVR PtL BATTRY R 238 PD RELIAtlCE 025 YES 44204-1 IST 17 F H H lt!43 trill-C04 C02 SUPVR PIL BATTRY R 238 PD RELIAtlCE 025 YES 44204-1 IST 17 F H H lt!43rrill-C05 CO2 SUPVR Pit DSL Ril 1 238 PD RELIAtlCE 015 YES 44204-1 IBT 17 F N H lt!43tPflL-C06 CO2 SUPVR Pill DSL Rh 1 238 PD RELIAriCE 015 YES 44204-1 IBT 17 F H H

_ Itt43xPifL-C07 CO2 SUPVR Pill DSL RH I 238 PD RELIAtICE 015 YES 44204-1 IST 17 F H H CS = COLD SHUT 00l#1 P = PIPE IfoUtlTED SBT=SIllGLE FREQUEtlCY QUALIFICATI0tl itILEST0 TIES REVISIDH 3 -JULY 1982 DA :DYHAttIC AtlALYSIS w TEST ARTICLE BIAXIAL TESTIrlG A =REEVALUATI0tl C0tIPLETE F =FLOCR lt0UtiTED B = REQUEST FOR QUAL OR BID ISSUED fl0TE8 NUtfBER IN HS =If0T STAtIDBY QP = QUALIFIED BY H =NEITHER CS OR flS C =S/H REC 0tillEffDATIDH TD LILCO ' TYPE flitIG' COLUt1H IS I:l3T=tfULTI-FREQUEtlCY PIPIllG AllALYSIS D = QUAL DOC RECEIVED QUANTITY OF ITEllS.

BIAXIAL TESTIllG SA = STATIC At!ALYSIS E =HARDHARE HODIFICATI0tl REQ'D

' It!ST=11ULTI-FREQUEHCY SAT =SINCLE FREQUEHCY F = QUAL DOC APVD & FILED SIllGLE AXIAL TESTIllG SINGLE AXIAL TESTIrlG G =SQRT PAPER C0ftPLETE H = COPIES OF DOC TO DISTRIBUTIDH l

SHO'iEllAtt (XIIT 1 CB LIST ST0tlE & HEBSTER EtlGINEERIllC CORPORATI0tl JOB flut1BER 11600 RUti DATE 07/22/82 3-SCRT C0tlTROL EUILDING CATEGORY I EQUIPitEtiT LILCO DOCHET 50-322 ACTIVE RUti tit!E 14.19.23 BOP QUALIFICATI0tl LEVEL 1210 ITEllS) PAGE 6 ftAPH EQUIPffEtlT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL tlUltPYR DESCRIPTI0tl fl0. RESP VEtIDOR ELEV ItlSP REPT t!ETH FREQ IITilG SHTDN STATUS It!13ePFL-C08 CO2 SUPVR PtL EffER SHG 238 PD RELIANCE 025 YES 44204-1 IBT 17 F tl If Ill43ertil-C09 CO2 SUPVR Pil ElfER SHG 238 PD RELIAtlCE 025 YES 44204-1 IfDT 17 F fl H lil13 mPFL-C10 CO2 SUPVR PIL EtIER SHG 238 PD RELIAtlCE 025 YES 44204-1 IST 17 F N H lil' 43 = Pill-C11 C02 SUPVR Pit C0ffPUTER 238 PD RELIANCE 044 YES 44204-1 IST 17 F N H IX41=ACU-14 cot!P, RELAY 1Ett SilGR RH 240 PD BAHilSON CO 044 YES A-47-75-01 SA 39 F2 CS HS H IX61aACU-07 CONTROL RColl A/C UtlITS 240 PD BAHNSON CD 063 YES A-47-75-01 SA 39 F2 CS.HS H 1R35vT-B1 XFitR-EffER 120V Pill B1 248 ED HAGilETICS 025 43424-1 YES IST 9 F CS,HS F 1R35aT-R1 XFitR-EttER 120V PtL R1 248 ED HAGilETICS 025 YES 43424-1 HBT 9 F CS.HS F 1R35mT-01 XFitR-EffER 120V PtL 01 248 ED HAGilETICS 025 YES 43424-1 HDT 9 F CS.HS F 1R35mT-203 XFR-IITR SPACE HTR-BUS 248 ED HAGilETICS 025 YES 43424-1 IfBT 9 F CS.HS F IX41mFil-029 RELAY 1EffER SHGR RET FH 270 PD BUFFALO FORGE 053 YES 74S-11139 SA 26 F2 CS.HS 11 IX41mFil-039 CR CHILL EQUIP Rif EXH 270 PD BUFFALO FORGE 067 YES 745-11140A SA 57 F2 CS.HS H IX41mFN-072 BATTERY Rig VENTILATION 270 PD BUFFALO FORGE 035 YES 74S-11140C SA 105 F3 CS.HS H

] IX60mrtf-028 DIESEL GEN Rll SUPPLY F 270 PD BUFFALO FORGE 040 YES 74S-11138 SA 20 F3 CS.HS H IT4SxPril-A2 liYD REC 0tIBINER CONT CA 289 PD ATotlICS INT 063 YES 54591-4 HDT 6 F2 N H lil50rPCV019 RDSV 1150 DIFF PRESS 310 CD FISIIER C0tlTROL 053 YES 2-24451 SA/ SAT 25 P2 CS H IP41mTCV055 CitTRL Rif & RBSVS HC-3 310 CD FISHER C0tlT. 063 YES CD76-20 SA 40 P6 CS.HS H IP41mTCV060 CtITRL Ril & RBSVS HC-4 310 CD FISHER C0 TIT. 063 YES CD76-20 SA 40 P6 CS,HS H IX41=TCV021 ACU-14 COOLING COIL 310 CD FISilER CONT. 053 YES 2-24451 SA 25 P2 CS H IX61sTCV021 ACU-7A C00LItfG UNIT 310 CD FISHER CONT. 071 YES 2-24451 SA 25 P2 CS H

_Itt50xA0V068 CHILLED HTR ISO BY 318 CD COPES VULCAff 071 YES 10.3.115 SA 124 P2 CS ells H CS = COLD StiUT DollN P = PIPE HOUllTED SBT=SIllGLE FREQUEilCY QUALIFICATION HILESTONES DA =DYllAffIC AtlALYSIS REVISION 3 -JULY 1982

  • TEST ARTICLE BIAXIAL TESTIrlG A =REEVALUATI0tl C0llPLETE F =FLOCR HOUtlTED HS =tt0T STAtIDBY B = REQUEST FOR QUAL OR BID ISSUED If0TE: flUlfSER IN QP = QUALIFIED BY N =tIEITHER CS OR HS C =S/H REC 0f ft1EllDATI0tl TO LILCO ' TYPE HillG' COLUlsti IS lt0T=f fULTI-FREQUEllCY PIPIllG AtlALYSIS D = QUAL DOC RECEIVED QUAtlTITY OF ITEtts.

BIAXIAL TESTIllG SA = STATIC AtlALYSIS E =HARDHARE ff0DIFICATION REQ'O IllST=ttULTI-FREQUENCY SAT = SINGLE FREQUEtiCY F = QUAL DOC APVD & FILED SIrlGLE AXIAL TESTING SINGLE AXIAL TESTING G =SQRT PAPER C0t1PLETE H = COPIES OF DOC TO DISTRIBUTI0tl

P'm]U l

SHOPEllAll UtlIT 1 CB LIST STottE & HEBSTER EttGIttEERIllG CORPORATI0tl l JOB ttutBER 11600 RUtt DATE 07/22/82 3-SORT C0t(TROL BUILDIllG CATEGCRY I EQUIPlfEt(T RUll tit!E 14.19.23 f LILCO DCCHET 50-322 ACTIVE BOP QUALIFICATI0tf LEVEL (210 ITEl!S) PAGE 7 l

IIARM EQUIPl!EtiT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL NUtOER DESCRIPTION FO. RESP vet 00R ELEV INSP REPT  !!ETH FREQ HTHG SHTDil STATUS lits 0sA0V069 CHILLED HTR ISO BY 318 CD COPES VULCAtl 075 YES 10.3.115 SA 124 P2 CS.HS H lit 50sLCV025 EH SYSTElf A ItAMEUP 318 CD COPES VULCAN 072 YES 10.3.115 SA 124 P2 CS eitS H lit 43sHSOO3 FIRE DET SH STA 319 ED POLLERS REG 044 YES 43812-1 IST 24 F3 CS.HS H lil'43 tHS006 FIRE DET SH STA 319 ED P0HERS REG 025 YES 43812-1 IIBT 24 F3 CS.HS H IX41mFS 013 ACU-14 AIR FLOH 319 ED P0HERS REG 031 YES 43812-1 IST 24 F2 CS.HS H IX41EFS 017 FN-29 AIR FLOH 319 ED pollers REG 044 YES 43812-1 IST 24 F2 CS ells H IX41tifE 021 ACU-14 C00LIllG CNTRL 319 ED P0HERS REG 044 YES 43912-1 HBT 24 F2 1

CS.HS H IX41t!!IT021 ACU-14 C00LItfG CHTRL 319 ED P0llERS REG 049 YES 43612-1 IBT 24 F2 CS.HS H IX11aff0D031 FN-039 OUTDOOR AIR 319 ED pollers REG 063 YES 43812-1 IBT 24 F2 CS,HS 11

' IX41stt00032 FH-039 EXHAUST AIR 319 ED P0llERS REG 064 YES 44540-1 IBT 27 F2 CS ells H IX41stt00035 ACU-14A DISCHARGE AIR 319 ED pollers REG 044 YES 43812-1 24 HDT F2 CS.HS H IX41st00036 Ott FAN FN-29A& B 319 ED P0HERS REG 044 YES 43812-1 IBT 24 F2 CS.HS H IX41EIOD039 Fil-72 OUTDOOR AIR 319 ED P0HERS REG 037 YES 44057-1 IIST 21 F3 CS.HS H IX41stt00040 FN-72 EXIfAUST AIR 319 ED pollers REG 041 YES 44057-1 IBT 21 F3 CS.HS H IX41stf00041 FN-72 RETURif AIR 319 ED pollers REG 035 YES 44057-1 IBT 21 F3 CS.HS H IX41stt00059 RELAY & CitPTR Rtt TEtP 319 HD P0llERS REG 044 44057-1 YES lET 21 F2 CS HS H IX41tPflLVC16 VErlT C0tITROL PAttEL 319 ED POHERS REG 025 YES 1001-6 SA/ SAT 24 F N H IX41tritLVC17 VElli cot { TROL PAtlEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F N H IX41artiLVC18 VEtiT C0t1 TROL PAllEL 319 ED P0ltERS REG 025 YES 1001-6 SA/ SAT 24 F H H IX41rPtiLVC19 vet 4T C0tiTROL PAllEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F CS.HS H

_ 1X41ErtlLVC20 VENT C0tiTROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F CS.HS H CS = COLD SituT DOHN P = PIPE HOUt{TED SBT=SIllGLE FREQUENCY QUALIFICATI0tl HILEST0tlES REVISIDH 3 -JULY 1982 DA =DYttAHIC ArtALYSIS

  • TEST ARTICLE BIAXIAL TESTING A = REEVALUATION C0tlPLETE F = FLOOR tt0UtITED B = REQUEST FOR QUAL OR BID ISSUED fl0TE: FAJtlCER IN HS =lt0T STATOBY QP = QUALIFIED BY H =HEITHER CS OR HS C =S/H REC 0fRIEtOATIDH TO LILCO ' TYPE HTHG' COLUttN IS IfBT=tTJLTI-FREQUEtlCY PIPIrlG AtlALYSIS D = QUAL DOC RECEIVED QUANTITY OF ITEttS.

DIAXIAL TESTIFIG SA = STATIC ANALYSIS E =HARDHARE ImDIFICATI0tl REQ'D 7ttST=tfULTI-FREQUEllCY SAT = SINGLE FREQUENCY F =0UAL DOC APVD & FILED SItiGLE AXIAL TESTIttG SINGLE AXIAL TESTING G =SQRT PAPER cot 1PLETE H =CUPIES OF DOC TO DISTRICUTICH

w__________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

SHORElfAll UNIT 1 CB LIST ST0 tie & HEBSTER ElGIllEERING CORPORATION JC3 IlUltBER 11600 RUll DATE 07/22/82 3-SORT CONTROL BUILDING CATEGORY I EQUIPl1EtIT LILCO DOCHET 50-322 ACTIVE RUti TIllE 14.19.23 BOP QUALIFICATI0ft LEVEL (210 ITEttS) PAGE 8 ftAPM EQUIPftEtiT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL iTJitBER DESCRIPTI0tl fl0. RESP VEilDOR ELEV INSP REPT ttETH FREQ IITtIG SHTDit STATUS 1X41mPNLVC21 VENT C0tiTROL PANEL 319 ED P0HERS REG 044 YES 1001-6 SA/ SAT 24 F CS.HS H IX41*TE 018 FN-72 DAt!PER CONTROL 319 ED P0HERS REG 030 43812-1 YES IDT 24 F3 CS.HS H IX41mTIS031 Fil-39 C0tiTROL 319 ED P0HERS REG 068 YES 43812-1 tIDT 24 F2 CS.HS H IX41sTT-001 Rtt TEllP IllD 319 ED P0HERS REG 025 43812-1 YES IBT 24 F2 H H IX41=TT-002 Rtl TEIP ItD 319 ED P0llERS REG O25 YES 43812-1 ffBT 24 F2 t! H IX41mTT-003 Rif TEt1P IIID 319 ED P0HERS REG 025 YES 43812-1 fBT 24 F2 H H IX41sTT-004 Ril TEIP IND 319 ED P0HERS REG 044 YES 43812-1 11DT 24 F2 N I!

1X41*TT-005 RII TEIP IIID 319 ED P0HERS REG 044 43812-1 YES IBT 24 F2 H H IX41=TT-006 CHILLER EQUIP Ril TEIP 319 ED P0HERS REG 068 43812-1 YES IBT 24 F2 H 11 1

IX41mTT-007 BAT Ril TEfP 319 ED P0HERS REG 039 43812-1 YES IBT 24 F2 fl H IX41*TT-009 C0ffPUTER Rif TEttP 319 ED P0HERS REG 044 YES 43812-1 IBT 24 F2 t! H IX60stt00031 FN-28 OUTDOOR AIR 319 ED P0HERS REG 038 YES 44057-1 IBT 21 F3 CS H '

IX60xtt00032 FH-39 Il0T DAIIPER 319 ED pollers REG 030 YES 44057-1 IBT 21 F3 CS H

/ IX60xit00033 Fil-28 RETURN AIR 319 ED P0HERS REG 038 YES 44057-1 fBT 21 F3 CS H '-

IX40xPtfLVC13 VENT C0f(TROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F CS,HS H IX60sPflLVC14 VENT CONTROL PAtlEL 319 ED P0HERS REG 025 YES 1001-6 CS,HS SA/ SAT 24 F H 1X60xPitLVC15 VEllT CONTROL PANEL 319 ED pollers REG 025 YES 1001-6 SA/ SAT 24 F CS.HS H IX61mA00037 CilTRL Rif ISOL 319 ED P0HERS REG 063 YES 44540-1 IfBT 27 F3 CS ells H IX61sFS 011 Fil-25 CNTRL 319 ED pollers REG 063 YES 43812-1 24 IST F2 CS itS H IX61mFS 012 ACU-7 AIR FLOH 319 ED P0llERS REG 063 YES 43812-1 IBT 24 F3 CS.HS H IX61mHS 038 IX61*A0V038 CortTROL 319 ED pollers REG 066 43812-1 YES IBT 24 F2 CS.HS H CS = COLD SHUT DOHN P = PIPE ff0UHTED SBT= SINGLE FREQUENCY QUALIFICATION HILEST0llES lDA:DYHA!!ICAtiALYSIS

  • TEST ARTICLE REVISION 3 -JULY 1982 BIAXIAL TESTING A = REEVALUATION C0llPLETE F = FLOOR 110UtiTED B = REQUEST FOR QUAL OR BID ISSUED fl0TE: NUtt0ER IN HS = HOT STAtiDBY QP = QUALIFIED BY H =HEITHER CS OR HS C =S/H REC 0tRIEtIDATION TO LILCO ' TYPE IITHG' COLUIRI IS IfDT:lfULTI-FREQUEtlCY PIPIHG ANALYSIS D = QUAL DOC RECEIVED QUAtiTITY OF ITEftS.

BIAXIAL TEST 1tlG SA = STATIC AtlALYSIS E =HARDilARE HODIFICATION REQ'O IlfST=ttULTI-FREQUEtICY SAT = SINGLE FREQUEllCY F = QUAL DOC APVD & FILED SillGLE AXIAL TESTING SINGLE AXIAL TESTING G =SQRT PAPER C0t1PLETE H = COPIES OF DOC TO DISTRIBUTIOli

,o _ _ _ _ _

vu SHOPEHAll UtIIT 1 C3 LIST STONE & HEBSTER EtIGIllEERIllG CORPORATICti JCB hut!BE2 11600 RUll DATE 07/22/82 3-SDRT C0tiTROL BUILDItIG CATEGORY I EQUIrllENT LILCO DOCHET 50-322 RUN TIltE 14.19.23 ACTIVE BOP QUALIFICATI0tl LEVEL 1210 ITEllS) PAGE 9 ftARN EQUIPl!EtIT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFE QUAL tlUttDER DESCRIPTION tl0. RESP vet 1 DOR ELEV IllSP REPT llETH FREQ llTilG SH10tl STATUS IX61stfE-021 ACU-7 CitTRL 319 ED P0HERS REG 063 YES 43012-1  !!DT 24 F2 CS,HS H 1X61st100033 FN-25 DISCH A1,1 319 ED P0HERS REG 063 YES 44540-1 IBT 27 F2 N H IX61stt00034 ACU-7 DISCHARGE AIR 319 ED P0llERS REG 063 YES 43812-1 IST 24 F2 CS HS H 1DllePFL-021 RDSBVS lf0tlITORIrlG PANE 332 PD tRfC 063 YES 45493-1 IBT 13 F H H 1D11mPit-022 RBSBVS HONITORIflG PANE 332 PD F5tC 063 YES 45493-1 IBT 13 F ti 11 ID11mPf L-025 CONT R00ftit0NITOR PtL 332 PD t#tC 044 YES 45493-1  !!DT 14 F2 H H ID11=PflL-026 CONT R00tlif0t4ITOR PFL 332 PD FEfC 044 YES 45493-1  !!3T 14 F2 H 11 ID11ertL-027 C0tlT Ril VENT IIOilIT PIL 332 PD t#tC 063 YES 45493-1 IET 13 F H H ID11=PtL-066 POST ACCOUNT lloit 332 PD F5tC 063 YES 45493-1 IBT 14 F H H IDllwPfL-067 POST ACCONT 'tollITORS 332 PD telC 063 YES 45493-1 IST 14 F H H ID11= Pit-068 POST ACCDitT llotlITORS 332 PD t#tC 063 YES 45493-1 IfST 14 F H H 1011tPtL-069 POST ACCDilT tt0tlITORS 332 PD talc 063 YES 45493-1 fBT 14 F H H ID11tPIL-080 RAD flotl PtL 332 PD t#tC 063 YES 45493-1 lET 6 F2 H H IT40xRH-25 HYDRO REC 0tB C0tTT CABI 344 ED DELPHI IND 063 YES 1035-5 SA/ SAT 29 F2 H G IT43rRH-26 HYDRO REC 0tB CONT CABI 344 ED DELPflI IND 063 YES 1935-5 SA/ SAT 29 F2 H G IP41tPS 008 SUCTI0tl Ill50mP-139B 348 CD ASCO 063 YES 178 SAT 50+ F2 CS.HS H IP41 CPS 009 SUCTION lits 0pP-140B 348 CD ASCO 063 YES 178 SAT 50+ F2 CS,HS H IB21mTE-037 IRI STil LINE TURB AREA 406 CD ROSEHONT 042 YES 2767 SAT 35+ F4 CS.HS G lil50xFT-043 HC-3 EVAP 406 CD ROSEff0NT 063 YES 127516 SBT 50 F2 CS,HS G lil50xFT-053 HC-4 EVAP 406 CD ROSEHONT 063 YES 127516 SBT 50 F2 CS.Ils G i

_Itt50rPDT019 RBSVS 1150 DIF PR 406 CD ROSEttotiT 063 YES 127516 SBT 50 F2 CS ells G CS = COLD SHUT DOHtt P = PIPE ffoUtlTED SBT=SItlGLE FREQUErlCY QUALIFICATIOli IIILEST0 TIES REVISI0tl 3 -JULY 1982 DA :DYilAttIC AtlALYSIS

  • TEST ARTICLE BIAXIAL TESTING A =REEVALUATI0tl C0tIPLETE F =FLOCR fl0UtITED B = REQUEST FOR QUAL OR BID ISSUED NOTE: flulBER Ill HS = HOT STAtIDBY QP = QUALIFIED BY H =HEITHER CS OR HS C =S/H REC 0lStEfCATION TO LILCO ' TYPE HTNG' COLUtti IS HDT=tfULTI-FREQUEllCY PIPIllG AtlALYSIS D =CUAL DOC RECEIVED DIAXIAL TESTIrlG QUArtTITY OF ITEllS.

~ SA = STATIC ANALYSIS E =HAR0 HARE HODIFICATION REQ'D llST=lIULTI-FREQUEtlCY SAT = SINGLE FREQUEllCY F = QUAL DOC APVD & FILED SIllGLE AXIAL TESTING SINGLE AXIAL TESTING G =SQRT PAPER CollPLETE H = COPIES OF DOC TO DISTRIBUTION

Sit 07ElffJ1 UtlIT 1 C3 LIST ST0!!E & llEDSTER EttGIllEERIt!S CORPORATIOil rut! DATE 07/22/82 JOD HUttBER 11600 3-SORT CotiTROL DUILDIrlG CATEGORY I EQUIPilEt4T RUti TIllE 14.19.23 LILCO DOCHET 50-322 ACTIVE BCP QUALIFICATI0tl LEVEL (210 ITEtts) PAGE 10 '

itARM EQUIPl!ErlT SPEC DIV. CLDG AVAIL QUAL QUAL TYPE SAFE QUAL F1UttDER DESCRIPTI0tl it3. RESP VEtiDOR ELEV IllSP REPT llETH FREQ HTilG SHTDil STATUS Ill50mTE 009 RCSVS CHILLED HTR SYS 406 CD ROSEtt0UtiT 078 YES 2767 SAT 35+ F2 CS.HS G IP41sFT 05'4 HC-3 C0tc HTR IN 406 CD ROSElt0 tit 063 YES 127516 IST 60+ F2 CS ells G IP41sFT 059 HC-4 COtID HTR Irf 406 CD ROSEi!O!(T 063 YES 127516 IST 60+ F2 CS.flS G IP41mTE 055 CitTRL Ril & RDSVS HC-3 406 CD ROSE!!OUtli 068 YES 2767 SAT 35+ F2 CSells G IP41wTE 060 CNTRL Rt1 & RBSVS HC-4 406 CD ROSEtt0UtlT 060 YES 2767 SAT 35+ F2 CS.HS G IX'ilwTE 021 ACU-14 COOLIttG CotiT 406 CD ROSEtt0UNT 044 YES 2767 SAT 35+ 'F2 C5.HS G

  • IX61*TE 0:1 ACU COCLIttG C0tli 406 CD ROSEtt0UTIT 067 YES 2767 SAT 35+ F2 CS.HS G lits 0rLS 002 ISOL DYP V A0V60A.69A 407 CD  !!AGNETROL 063 YES 43235-1 IBT 17 F2 14 S G lits 0xlS 025 CH SYSTEtt A ItAMEUP 407 CD t!AGilETROL 063 YES 43235-1 IST 17 F2 HS G 1R43aLS 004 FUEL OIL AUX DAY TH 407 CD itAGtIE TROL 022 YES 43235-1 SAT 17 F3 il H 1R43nLS 007 FUEL OIL AUX DAY TH 407 CD HAGilETROL 022 YES 43235-1 SAT 17 F3 N H 11150rA0V062 RBSVS & CRAC 423 CD FISHER 071 YES CD76-62 SAT 23 P2 CS.HS H lif50xA0V063 RBSVS & CRAC 423 CD FISHER 071 YES CD76-82 SAT 23 P2 CS.HS H IP41sA0V016 DIESEL ltX E-13A CUTLET 423 CD FISilER 025 YES CD76-82 SA 23 P3 CS H IG11sLTS-6'82 TH56 LEVEL 473 CD DELAVAL 063 F B l

1G11rLTS-645 RB FLOOD LEVEL 473 CD DELAVAL C63 F2 B ID11tPitL-117 RAD lt0N SYS It0 475 PD HA!!Att 063 F2 B 1D11tPitL-126 STA VENT tto!IITOR 475 PD HAltAtt 063 YES 16435 IST 4 F H H 1011tritL-134 RD SVS ItotIITOR 475 PD HAllAN 113 YES 16435 IOT 4 F H H ID11tritL-135 llICROCot1P FOR PflL126 475 PD HA!!AN 063 YES 16435-A IDT 19 F fl H

_ID11EPitL-137 111CROC0!!P FOR PIA.13'4 475 PD HA!!Att 063 YES 16435-A ItST 19 F H H CS = COLD SItUT DOltri P = PIPE It0UtiTED SST=SIrlGLE FREQUEllCY CUALIFICATIO!I IIILEST0!!ES REVISIori 3 -JULY 1902 DA :DYriAllIC AtIALYSIS w TEST ARTICLE BIAXIAL TESTIIIG A =REEVALUATIO!I C0!!PLETE F = FLOOR tt0UtiTED B = REQUEST FOR QUAL OR BID ISSUED F40TE: fiU!OER IN HS = HOT STAttDDY QP = QUALIFIED BY li =HEITHER CS OR HS C =S/H REC 0!!!!Et0ATI0tl TO LILCO ' TYPE 11TilG' COLUt1H IS ItDT=ttULTI-FREQUEtlCY ~ PIPIT 1G AtIALYSIS D = QUAL DOC RECEIVED QUAT 4TITY OF ITEttS.

~

DIAXIAL TESTIttG SA = STATIC AttALYSIS E =HARDHARE tt0DIFICATIOff REQ'D llST=ttULTI-FREQUEllCY SAT =SItiGLE FREQUEllCY F = QUAL DOC APVD & FILED SItiGLE AXIAL TESTIttG SIllSLE AXIAL TESTIllG G =SQRT PAPER cot!PLETE H = COPIES OF DOC TO DISTRICUTION

w_ . . _ . - . _ _ . _ . ____ _ ___ _

SHOREHAll UNIT 1 RBPfl LIST STONE & HEBSTER ENGINEERING CORPORATION JOB ltUIEER 11600 3-SORT RUN DATE 07/22/82 CEACTOR BUILDING CATEGORY I PIPE HOLfiTED EQUIPHENT RUN TIttE 14.20.22 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (326 ITEHS) PAGE 1 I

5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ItARN PIPE QUAL SPEC LOC.

m NUttDER SIZE REPT 10. HOR VER SUPPLIER llODEL 70. YOME OPER IT46mA0V035A 72 R-1062-41 111 SC BETTIS 2.7 .6 T-316 SR2-H3 H H 1746sA0V0358 72 R-1062-41 111 SC 5.2 BETTIS

! i .6 T-316 SR2-It3 H H IT46eA0V037A 72 CD75-35 111 SC 1.0 .7 BETTIS T-316 SR2-It3 H H IT46mA0V037B 72 CD75-35 111 SC BETTIS i

,, .8 .4 T-316 SR2-H3 H H ITadmA0V038A 18 CD76-82 172 PC 2.2 1.2 BETTIS 722C-SR-II3 H H IT46aA0V0388 18 CD76-82 172 SC 1.2 1.1 BETTIS f ' 722C-SR-il3 H H 1T46wA0V03BC 18 CD76-82 172 SC 1.8 1.3 BETTIS 722C-SR-H3 H H I

IT46mA0V0300 18 CD76-82 172 SC 1.3 1.2 BETTIS O 722C-SR-If3 H H 1T46sA0V039A 18 CD76-82 172 PC 2.2 1.2 BETTIS 722C-SR-H3 H H IT46vA0V039B 18 CD76-82 172 SC 1.2 1.1 BETTIS (3 722C-SR-It3 H H l 1T46mA0V039C 18 CD76-82 172 SC 2.3 BETTIS

.8 722C-SR-H3 H H IT46sA0V039D 18 CD76-82 172 SC 1.8 BETTIS

.8 722C-SR-t!3 H

(^ '

H 1821=RV 093 24 TR-77-18 175 SC _., B _

IE51 MRV 145 .75 502644 191 SC .6 .2 . H l '

1E51=RV 146 .75 502644 191 SC .6 .2 H _

IE51 MRV 147 1.25 502644 191 SC .6 .2 H

( _

IE51 MRV 149 1.25 502644 191 SC .6 .2 H _

IP41mfl0V033A 20 0-0034-8 197 SC LIMITORQUE 1

.8 .8 H2BC/Ste0010 H H IP41mHOV033B 20 D-0034-8 197 SC .7 .5 LIMITORQUE H2BC/SitB0010 H H

~

QUA8.IFICATION HILESTONES NOTES REVISION 3 -JULY 1982 1 '

A : REEVALUATION C0fPLETE 1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE 5. PRESEtiT QUALIFICATION VALID B : REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG- 5 ) FOR OPERATOR LOADS < OR = 3 G'S C :S/M REC 0ftlEt0ATION TO LILCO 2. * = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AND VERTICAltFAULTED) i D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 6. IF OHLY ONE LOAD IS GIVEN FOR

_ E=HARDHARE ISODIFICATION REQ'D FLOOR-HOUNTED (EllTG-5) THE OPERATOR, IT IS THE HAXIffUH '

F = QUAL DOC APVD & FILED 4. 2/1 = 2 IN. CLASS 1

( G :SQRT PAPER COHPLETE H = COPIES OF COC TO DISTRIBUTION

SHOREllAll UNIT 1 RBPH LIST ST0tlE & HEBSTER ENGIttEERING CORPORATI0ti I~ RUN DATE 07/22/82 JOB tlUtBE011600 3-SORT DEACTOR BUILDIttG CATEGORY I PIPE tt0UNTED EQUIPitEllT LILCO DOCHET 50-322 RUti TIltE 14.20.22 ACTIVE BOP QUALIFICATION LEVEL (326 ITEttS) PAGE 2 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ItARN PIPE QUAL SPEC LOC.

ilUt BER SIZE REPT PC. HOR VER

, SUPPLIER 100EL to. YONE OPER IP41mit0V033C 20 D-0034-5 197 SC 1.0 LIttITORQUE

.5 H2BC/SitB0005 H H IP41mif0V033D 20 D-0034-5 197 SC LIllITORQUE f

.7 .8 H2BC/StID0005 H H 1P41=tt0V034A 20 D-0034-8 197 SC .1 .1 LIttITORQUE H2BC/ stb 010 H H IP41stt0V034B 20 D-0034-8 197 SC .6 .5 LIllITORQUE H2BC/SitB010 H H IP41stt0V037A 16 D-0034-2 197 SC .7 LIttITORQUE

.5 H2BC/ stb 005 H H IP41mtf0V037B 16 D-0034-2 197 SC .8 .8 LIllITORQUE H2BC/S!!D005

(' H H IP41 sit 0V042A 6 D-0034-9 197 SC 1.2 2.1 LIMITORQUE H0BC/SitB002 H H IP41stt0V0428 6 0-0034-9 197 SC 1.0 1.8 LIMITORQUE

(% H0BC/ stb 002 H H IG41st!OV032A 6 1891-1 203 SC 1.3 .9 LIMITOROUE Ste-00-10 H H IG41att0V032B 6 1891-1 203 SC .7 .6 LIllITORQUE St B-00-10 H H

( ,

IP41mit0V039A 1/3 1891-1 203 SC 1.5 1.3 LIllITORQUE stb-000-2 H H

, IP41 sit 0V039B 1/3 1891-1 203 SC 1.5 1.3 LIIIITORQUE stb-000-2 H H IP41stt0V043 1/3 1891-1 203 SC 1.5 1.3 LIMITORQUE SIB-000-2 H H IP41mitOV102A 1/3 1891-1 203 SC 1.5 1.3 LIttITORQUE SIB-000-2 H H IP41ml10V102B 1/3 1891-1 203 SC 1.5 1.3 LIMITORQUE stb-000-2 H H IP50 sit 0V103A 1.5/2 SR-6189 214 SC 1.5 1.3 LIHITORQUE stb-000-5 H H

{.

IP50*lt0V103B 1.5/2 SR-6189 214 SC 1.5 1.3 LIMITORQUE stb-000-5 H H IP50mit0V104 1 214 SC 1.5 1.3 LIMITORQUE SHB-000-2 B F IP50mitOV105A 1.5/2 214 PC 6.9 3.0 LIMITORQUE 592-000-5 B F

~

QUALIFICATION HILEST0tlES tl0TES REVISI0t1 3 -JULY 1982 b

A = REEVALUATION C0tFLETE 1. CL 2 AFB 3 VALVES < OR = 2 IN. ARE 5. PRESEtIT QUALIFICATI0tl VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-It0UNTED (EllTG- 5 3 FOR OPERATOR LOADS < OR = 3 G'S C =S/H REC 0ttitEtBATION TO LILCO 2. m = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AND VERTICAltFAULTED)

D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 Irl. ARE 6. IF Ote.Y ONE LOAD IS GIVEN FOR E=HARDilARE If0DIFICATION REQ'D FLOOR-It0UNTED (EHTG-5) THE OPERATOR. IT IS THE HAXIlfUH I F = QUAL DOC APVD & FILED 4. 2/1 = 2 IM. CLASS 1 i~~ G =SQRT PAPER ColFLETE H = COPIES OF DOC TO DISTRIDUTION I

x-SHOPEHAll UllIT 1 RDPH LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 07/22/82

~

l JOB flulGER 11600 3-30RT REACTOR BUILDING CATEGORY I PIPE HO'JNTED EQUIPilEHT LILCO 00CHET 50-322 RUN TIHE 14.20.22 ACTIVE BOP QUALIFICATION LEVEL (326 ITEllS) PAGE 3 i

5 7 8 I

i 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS IIARM PIPE QUAL SPEC LOC.

} ilUlfBER SIZE REPT NO. HOR VER SUPPLIER HODEL NO.

YOHE OPER I

IP50ml0V105B 1.5/2 214 PC 4.9 3.0 LIHITORQUE stb-000-5 8 F IP50mHOV106 1 214 SC 1.3 l

1.5 LIllITORQUE SIB-000-2 B F l IP50mit0V113A 1 214 SC 1.5 1.3 LIMITORQUE SHB-000-5 B F IP50mit0V113B 1 214 SC 1.5 1.3 LIIIITORQUE SIB-000-5 B F b IP50mif0V114A 1 l 214 SC 1.5 1.3 LIllITORQUE SIB-000-5 8 F 1P50mt!OV114B 1 214 SC 1.5 1.3 LIllITORQUE SIB-000-5 B F

(

IT23 110V031A .5 SR-6341 214 SC 1.5 1.3 LIMITORQUE SIB-000-2 H H 1T23ml0V031B .5 SR-6341 214 SC

.. 1.5 1.3 LIMITORQUE SIB-000-2 H H 1821mif0V061 2/1 253 SC 1.8 1.0 LIHITORQUE SIB-00-10 B F IB21=lt0V062 2/1 253 SC 1.4 1.T LIHITORQUE SIB-00-10 8 F IB21=lt0V063 2/1 253 SC 2.0 1.2 LIltITORQUE stb-00-10 B F f,

1B21=lf0V064 2/1 253 SC 1.8 1.2 LIMITORQUE SIB-00-10 B F l IB21=lOV068A 2/1 SR-6188 253 SC 1.4 .9 LIHITORQUE SIB-000-5 H H 1821mif0V0688 2/1 SR-6188 253 SC 1.4 3.8 LIlfITORQUE Sle-000-5 H H

(' l IB21=ll0V068C 2/1 SR-6188 253 SC 1.8 .9 LIMITORQUE SIB-000-5 H H IB21mit0V0680 2/1 SR-6188 253 SC 1.4 1.1 LIllITORQUE SHB-000-5 H H

{,

1821=10V083 2/1 SR-6188 253 PC 1.2 2.0 LIMITORQUE SIB-000-5 H H IB21s!OV004 2/1 SR-6188 253 PC 1.6 1.2 LIHITORQUE SIB-000-5 H i

H IB21mit0VO85 2/1 SR-6188 253 PC 1.8 1.5 LIHITORQUE SIB-000-5 H H QUALIFICATI0ft HILESTONES 10TES REVISION 3 -JULY 1982 O~

A = REEVALUATION ColFLETE 1. CL 2 Ale 3 VALVES < OR = 2 IN. ARE 5. PRESEllT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-il0UNTED (EllTG- 5 ) FOR OPERATOR LOADS < OR = 3 G'S C =S/H RECOIRfENDATION TO LILCO 2. * = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL Als VERTICALIFAULTED)

D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 6. IF Olt.Y ONE LOAD IS GIVEN FOR E=HARollARE IODIFICATION REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR IT IS THE HAXIllUH I F = QUAL DOC APVD & FILED 4. 2/1 = 2 IH. CLASS 1 (1 G =SQRT PAPER COMPLETE H = COPIES OF DOC TO DISTRIBUTION

SHOREHAll UtlIT 1 RBPH LIST ST0 TIE & NEBSTER EttGIllEERIrlG CORPORATION i JOB IM IER 11600 RUti OATE 07/22/82 3-SORT REACTOR BUILDIrlG CATEGORY I PIPE HOUt4TED EQUIrttENT LILCO 00CHET 50-322 RUti TIHE 14.20.22 ACTIVE BOP QUALIFICATI0tl LEVEL (326 ITEllS) PAGE 4 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ItARN PIPE QUAL SPEC LOC.

tutBER SIZE REPT tl0. HGR VER SUPPLIER tt00EL t10. YOHE OPER 1011 sit 0V032A 1 253 PC 6.9 3.0 LIHITORQUE SIB-000-2 B F ID11stt0V0328 1 253 SC 1.5 1.3 LIHITORQUE stb-000-2 D C 1011stt0V033A F

1 253 PC 6.9 3.0 LIttITORQUE stb-000-2 B F 1011stIOV033B 1 253 SC 1.5 1.3 LIHITORQUE St B-000-2 8 F (T

1E11 wit 0V055A 1 SR-6190 253 SC 1.3 1.5 LIllITORQUE stb-000-2 H H IE11*tt0V055B 1 SR-6190 253 SC 1.5 1.3 LIllITORQUE stb-000-2 H H (7 .

IE11stIOV056 A 1 SR-6190 253 SC 1.5 1.3 LIMITORQUE stb-000-2 H H IE11s!IOV056B 1 SR-6190 253 '

i SC 1.5 1.3 LIHITOROUE stb-000-2 H H 1E11stt0V057A 1 253 SC 1.5 1.3 LIMITORQUE Ste-000-2 B F IE11ut t0V057B 1 253 SC 1.5 1.3

-. LIIIITORQUE SIB-000-2 8 F 1E32mftOV021A 1.5/1 253 SC 2.5 1.3 LIHITORQUE SHC-04-5 B F 1E32*l!0V021B 1.5/1 253 SC 2.8 1.9 LIHITORQUE SitC-04-5 B F

(' IE32mit0V021C 1.5/1 253 SC 2.5 2.4 LIHITORQUE SitC-04-5 B F IE32*tt0V021D 1.5/1 253 SC 2.4 1.5 LIttITORQUE SitC-04-5

(' B F IE32 mil 0V022A 1.5/2 253 SC 2.3 1.5 LIMITORQUE SIIC-04-3 B F 1E32al10V022B 1.5/2 253 SC 2.0 1.7 LIHITORQUE SitC-04-3 8 F O' IE32=tt0V022C 1.5/2 253 SC 2.2 2.7 LIHITORQUE StIC-04-3 B F 1E32al10V022D 1.5/2 253 SC 2.4 LIHITORQUE StIC-04-3

,, .8 8 F 1E32aff0V023A 1.5/2 253 SC 1.5 1.3 LIMITORQUE SitC-04-3 B F

~

QUALIFICATION llILESTONES NOTES REVISION 3 -JULY 1982

(.

A =REEVALUATI0tl CotFLETE 1. CL 2 AtB 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATI0tl VALID B : REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG- 5 i FOR OPERATOR LOADS < OR = 3 G'S C =S/H REC 0!BtEllDATION TO LILCO 2. * = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AfD VERTICAL (FAULTEDI D QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 6. IF OtLY ONE LOAD IS GIVEN FOR ErHARDilARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-53 THE OPERATOR. IT IS THE HAXIIIUH I F = QUAL 00C APVD & FILED 4. 2/1 = 2 IN. CLASS 1

  • G =SQRT PAPER C0tFLETE H = COPIES OF DOC TO DISTRIBUTION 4

4 SHOREllAll UNIT 1 RIPH LIST STONE & HEBSTER EtlCINEERIrlG CORPORATI0tl O JOB tlulOER 11600 RUti DATE 07/22/82 3-SORT LILCO DOCHET 50-322 REACTOR BUILDIrlG CATEGORY I PIPE It0UtiTED EQUIPitENT RUti TIttE IQ.20.22 ACTIVE BOP QUALIFICATION LEVEL (326 ITEtts) PAGE 5 i '

5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ffARH PIPE QUAL SPEC LOC.

tRJtBER SIZE REPT to. HOR VER SUPPLIER tt00EL NO. YDHE OPER _

IE32=tt0V0238 1.5/2 253 SC 1.5 1.3 LIllITORQUE SitC-04-3 B F IE32att0V023C 1.5/2 253 SC 1.5 1.3 LIllITORQUE SHC-04-3 i,, B F 1E32mit0V023D 1.5/2 253 SC 1.5 1.3 LIMITORQUE SitC-04-3 B F 1E32n!OV024 2/2 SR-6188 253 SC 2.1 1.2 LIMITORQUE Ste-000-5 e

H H IE32 ell 0V025 2/2 SR-6188 253 SC 1.5 1.3 LIMITORQUE St B-000-5 H H IE32*tl0V026 2/2 SR-6188 253 SC 1.4 .9 LIHITORQUE SIB-000-5 H H 1E32 wit 0V027 2/2 SR-6188 253 SC 1.5 1.3 LIMITORQUE SIB-000-5 H H

IE41stt0V039 2/2 SR-6188 253 SC 1.5 1.3 LIMITORQUE Ste-00-5 w
, H H IE41stt0V047 1/1
SR-6190 253 PC 4.0 .5 LIMITORQUE Ste-000-2 H H i

1E41mit0V048 1/1 SR-6190 253 SC .9 2.0 LIHITORQUE stb-000-2m H H IE41mit0V049 2/2 SR-6188 253 SC 1.9 3.0 LIMITORQUE stb-000-2m H H IE51ml10V036 2/2 SR-6188 253 SC 1.5 1.3 LIMITORQUE SHB-C00-5

  • H H O 1E51mit0V038 2/2 SR-6188 253 SC 1.5 1.3 LIMITORQUE stb-000-5
  • H H IE51er10V046 2/2 SR-6188 253 SC 1.5 1.3 r s LIMITORQUE stb-000-2 m H H IE51mit0V047 1/1 SR-6190 253 PC 5.3 1.6 LIMITORQUE St B-000-2 H H IE51mit0V048 1/1 SR-6190 253 SC 8.7 2.0 LIMITORQUE stb-000-2 m D F O 1E51stt0V049 1.5/2 SR-6189 253 SC 1.5 1.3 LIMITORQUE stb-000-2 m H H IT40ntt0V004 1 253 SC 1.5 1.3 LIMITORQUE stb-000-2 B F IP41*lt0V129A 10 15438 281 SC 1.1 1.4 LIHITORQUE HIBC/ SIB 0002 F F

~

QUALIFICATI0tl llILEST0tlES NOTES REVISI0tt 3 -JULY 1982 h

A = REEVALUATION C0tPLETE 1. CL 2 AtB 3 vat VES < OR = 2 IH. ARE 5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (ElfTG- 5 I FOR OPERATOR LOADS < OR = 3 G'S C =S/H REC 0f0tEIDATION TO LILCO 2. m = DC HOTOR. ALL OTHERS ARE AC HORIZOHTAL AtO VERTICAltFAULTEDI D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IH. ARE 6. IF OtLY ONE LOAD IS GIVEN FOR E=HARDHARE It00IFICATION REQ'D FLOOR-H0utlTED (EHTG-5) THE OPERATOR. IT IS THE HAXIllUlf I- F = QUAL DOC APVD & FILED 4, 2/1 = 2 Ill. CLASS 1

(_

  • G =SQRT PAPER C0tFLETE H = COPIES OF DOC TO DISTRIBUTIDH

(

SHOREHAN tRIIT 1 RBPH LIST STONE & HEBSTE2 ENGINEERIt0 CORPORATION RUtf DATE 07/22/82 O JOB IU 2ER 11600 3-SDRT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIP!fEHT LILCO DOCHET 50-322 ACTIVE RUN TIHE 14.20.22 BOP QUALIFICATI0tl LEVEL (326 ITEtts) PAGE 6 O 5 1

7 8 2 3 4 OPER LOAD-G'S OPERATOR 6 ItARN PIPE QUAL STATUS QUAL SPEC LOC.

tutBER SIZE REPT NO. HOR VER SUPPLIER PODEL No. YOHE OPER IP41mHOV129B 10 15438 281 SC 1.9 1.8 LIMITORQUE H1BC/SHB0002 F F IE41mPCV142 2/2 2-24451 310 SC 1.5 1.3

(

BECH 14-101-ES H H 1E51mPCV142 2/2 2-24451 310 SC 1.5 1.3 BECH 14-101-DBQ H H IT46mTCV-022A 4 2-2'4451 310 SC 1.2 .6 BECH 14-101-ES H H

'{ IT46mTCV-022B 4 2-24451 310 SC 1.0 .5 BECM 14-101-ES H H IT46mTCV-023A 4 2-24451

( IT46mTCV-023B 4 2-24451 310 310 SC 1.1 .2 BECH 14-101-ES H H SC .8 .8 BECK 14-101-ES H H IT46mTCV-021A 4 2-24451 310 SC .6 p '

.9 BECM 14-101-ES H H 1T46mTCV-0248 4 2-24451 310 SC 1.1 .6 BECH 14-101-ES H H IT46mTCV-025A 4 2-24451 310 SC 1.2 .7 BECH 14-101-ES ,

H' H s

1T46*TCV-025B 4 2-24451 310 SC .4 .5 BECH 14-101-ES H H IT46mTCV-026A 4 2-24451 310 SC .1

.8 BECH 14-101-ES H H C~ '

1T46mTCV-026B 4 2-24451' 310 SC .7 .5 BECH 14-101-ES H H IT46*TCV-028A 2/3 2-24451 310 SC 1.5 1.3 BECH 14-101-ES H H IT46*TCV-028B 2/3 2-24451 310 SC r.5 1.3 BECM 14-101-ES H H IT46mTCV059A 2/3 2-24451A 310 SC 1.1 BECH '

.6 14-101-ES O IT46*TCV059B 2/3 2-21451A H H 310 SC 1.5 1.3 BECH 14-101-ES H H

~

IT46mTCV060A 2/3 2-24451A 310 SC .6 .7 BECH 14-101-E5 H H IT46mTCV0608 2/3 24451A 310 SC 1.5 1.3 DECM 14-101-ES H H

-QUALIFICATION HILESTONES NOTES REVISIDH 3 -JULY 1982 O -

A = REEVALUATION C0tFLETE 1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED IEHTG- 5 ) FOR OPERATOR LOADS < OR = 3 G'S C =S/H REC 0t3tEleATIDH TO LILCO 2. * = DC HOTOR. ALL OTHERS ARE AC D = QUAL DOC RECEIVED HORIZONTAL AFB VERTICAltFAULTEDI

3. CL 1 VALVES < OR = 1 IN. ARE 6. IF ONLY ONE LOAD IS GIVEN FOR E=HAROHARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR, IT IS THE HAXItui 7 F = QUAL DOC APVD & FILED 4. 2/1 = 2 IH. CLASS 1 h G =SQRT OAPER COlFLETE H = COPIES OF DOC TO DISTRIBUTION N-

/

b

uv SHORElfAH UFIIT 1 RBPH LIST ST0tlE & HEBSTED ENGINEERING CORPORATION i

~f' RUN DATE 07/22/82 JOB iMEED IMOG 3-SDRT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPl!ENT RUN TIHE 14.20.22 LItcri Occ,(ET 50-322 ACTIVE BOP QUALIFICATION LEVEL (326 ITEtts) PAGE 7 -

5 7 8 1 2 3 4 OPER LOAD-G'S

' OPERATOR 6 QUAL STATUS

-- ItARK PIPE QUAL SPEC LOC.

HUl!BER SIZE REPT HO. HOR VER SUPPLIFR HODEL HO. Yoke OPER 1831mA0V001 .75 10.3.115 318 PC 1.0 2.5 COPES D-100-60 H H 1831mA0V082 .75 10.3.115 318 SC .6 .6 COPES D-100-60 H H lE11=A0V061A .75 10.3.115 318 SC 1.5 1.3 COPES D-100-60 H H IE11sA0V061B .75 10.3.115 318 SC 1.5 1.3 COPES D-100-60 H H IE11*A0V062A .75 10.3.115 318 SC 1.5 1.3 COPES D-100-60 H H IElluA0V0620 ' .75 10.3.115 318- SC 1.5 1.3 COPES D-100-60 H H

? 1E11mPCV003A 10 10.3.115 318 SC 2.9 3.0 COPES D-100-160 H H IE11mPCV0038 10 10.3.115 318 SC .9 .6 COPES D-100-160 H H IE11mPCV007A 4 10.3.115 318 SC 1.2 .9 COPES D-100-100 H H IE11*PCV0073 4 10.3.115 318 SC .6 1.3 COPES D-100-100 H H 1541mA0V081 1 10.3.115 318 SC 1.5 1.3 ;0 PES D-100-60 H H IE41mA0V082 1 10.3.115 318 SC 1.5 1.3 COPES D-100-60 H H t'

1E41mA0V083 1 10.3.115 318 SC 1.5 1.3 COPES D-100-60 H H -

IE41*LCV-091 1 -}0.3.115 318 SC 1.5 1.3 COPES D-100-60 H H

(_

l IE41*LCV095 1 10 3.115 318 SC 1.5 1.3 COPES D-100-60 H H

~

IE51*A0V081 1 10.3.115 318 SC 1.5 1.3 COPES D-100-60 H H

+

IE51>A0V082 1 ' 10.3.115 310 SC 1.5 1.3 COPES D-100-60 H H 1E51=A0V083 1 10.3.115 318 SC 1;5 1.3 COPE 3 D-100-60 H H IE51*LCV091 1 10.3.115 318 SC 1.5 1.3 COPES D-100-60 N H

~

QUALIFICATION HILESTONES NOTES REVISION 3 -JULY 1982 l

A = REEVALUATION COlFLETE 1. CL 2 Arm 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATION VALID D = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EllTG- 5 ) FOR OPERATOR LOADS < OR = 3 S'S

( C =S/H REcotRIENDATI0tl TO LILCO 2. * = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AND VERTICAL (FAULTED)

D -QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 6. IF OtA.Y OtlE LOAD IS GIVEN FOR

~ E:HARDHARE ff00IFICATION REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR, IT IS THE flAXIHUll

- F =0UAL DOC APVD & FILED 4. 2/1 = 2 IN. CLASS 1

( G =SQRT PAPER C0tFLETE H = COPIES OF DOC TO DISTRIBUTION I

SHOREHAH UNIT 1 RBPH LIST

' ST0ffE & HEBSTE3 ENGIriEERING CORPOP.*.TI0tt RUN 0*.TE 07/22/82 JOB hut 2E2 11600 3-50RT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPHENT RUN TIHE 14.20.22 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (326 ITEttS) PAGE 8 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 ItARH PIPE QUAL STATUS QUAL SPEC LOC.

NUltBER SIZE REPT NO. HOR VER SUPPLIER ,

', If00EL NO. YOHE OPER -

g

~

IE51stCV095 1 10.3.115 318 SC

, o, 1.5 1.3 COPES D-100-60 H H ,

y IP42ePCV071 6 10.3.115 318 SC

_ 1.2 .5 COPES D-100-60 H H

+

1T24aA0V001A 4 10.3.151 318 SC 4.8 3.6 .

COPES D-100-100 D 0 s_

  • IT24mA0V0018 4 10.3.151 318 SC

( 2.9 3.7 COPES D-100-100 ' O' % D -

IT24=A0V004A 4 10.3.151 318 SC 1.9 1.2 COPES D-100-100 D, D - N IT24vA0V0048 4 10.3.151 318 SC 3.2 2.2 *

p. COPES D-100-100 D D IT46sA0V078A 6 10.3.145 318 PC 2.5 1.5 COPES D-100-100 H H IT46sA0V0788 6 10.3.145 318 SC 2.3 1.3 COPES D-100-100 H H

(' ' IT46mA0V079A

. r 6 10.3.151 318 SC 3.7 1.4 COPES D-100-100 H H

. 4 x IT46mA0V0798 4 10.3.151 318 SC 2.4 1.9 COPES " 'D-100-100' N H q

. - .. t IP42*TCV001H 12 CD76-82 423 SC 1.4 1.6 FISH'ER 654-60 % H. H i P IP42nTCV001X 10 CD76-82 423 SC.' 1.3 3.1 ' ~

FISHER 654-60 H H IP42mTCV001Y 12 CD74-82 423 SC 1.9 1.4 FISHER 656-60 H H e IP42=TCV001Z 10 CD76-82 423 SC 2.0 1.8 FISHER 654-60 - ~

H H f

IB21=SOV313A .75 IR5265683271 4GO - SC 1.5 1.3 H _

i IB21mSOV313B .75 HRS 265683271 600 SC 1.5 1.3 s H *

.75 IB21=SOV3144 IR5265683271 600 SC 1.5 1.3 H _

IB21*SCV3148 .75 IR5265683271 600 SC 1.5 1.3 H

(. . _

IE11mSOV164A .75 IRS 265683271 600 SC 1.5 1.3 H _

~

QUALIFICATION HILEST0tlES NOTES REVISION 3 -JULY 1982

(.

A = REEVALUATION C0lFLEIC 1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE 5. PRESENT GUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EllTG- 5 ) FOR OPERATOR LOADS < OR = 3 G'S C =S/H REC 0tRIEteATION TO LILCO 2. = = DC HOTOR. ALL OTHERS ARE AC HORIZOHTAL A!ID VERTICAL (FAULTED)

D = QUAL 00C RECEIVED 3. CL 1 VALVES < OR = 1 IH. ARE 6. IF Ot4.Y ONE LOAD 15 GIVEN FOR E=HARDHARE HODIFICATIDH REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR. IT IS THE HAXIHUH I F = QUAL DOC APVD & FILED 4. 2/1 = 2 IM. CLASS 1 G =SQRT PAPER CollPLETE

  • H = COPIES OF DOC TO DISTRIBUTION

. . - _ - . _ _ - - , _ , _ _ ~ _ . - - .

4 SHOREHAH UNIT 1 RBPfl LIST STONE & HEBSTE~I ENGIIIEERING CORPORATI0ti

(_ JOB NUIRER 11600 RUN 0%TE 07/22/02

3-50RT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPHENT LILCO DOCHET 50-322 ACTIVE RUN TIHE 14.20.22 BOP OUALIFICATION LEVEL (326 ITEHS) PAGE 9 l

5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 4 QUAL STATUS HARH PIPE QUAL SPEC LOC.

NUHBER SIZE REPT im. HOR VER SUPPLIER H00EL NO. YONE OPER 2

1E11mSOV1668 .75 PR5265683271 400 SC 1.5 1.3 H _

I IE11mSOV167A .75 195265683271 600 SC 1.5 1.3 H _

1E11mSOV1678 .75 IR5265683271 600 SC 1.5 1.3 H _

1E11mSOV168 .75 HR5265683271 600 SC 1.5 1.3 H _

IE11mSOV169 .75 HR5265683271 400 SC 1.5 1.3 H t _

IT48mSOV126A .75 195265683271 600 , SC 1.5 1.3 H _

IT48v50V1268 .75 PRS 265683271 600 SC 1.5 1.3 H _

'IT48w50V127A .75 IR5265683271 400 SC 1.5 1.3 H _

IT48mSOV1278 .75 IR5245683271 400 SC 1.5 1.3 H _

IT40=SOV128A .75 >R5265683271 400 SC 1.5 1.3 H _

IT48mSOV1288 .75 IR5265683271 600 SC 1.5 1.3 H _

IT48mSOV129A .75 195265683271 400 SC 1.5 1.3 H

(

IT48w50V1298 .75 PRS 265683271 600 SC 1.5 1.3 H _

IT4GwSOV130 .75 PR5265683271 400 SC 1.5 1.3

( H _

IT48uSOV131 .75 IR5265683271 400 SC 1.5 1.3

, H _

IT48aSDV136A .75 tR5265683271 600 SC 1.5 1.3 H _

I (

1T48sSOV1365 .75 1R5265683271 600 SC 1.5 1.3 H _

IT48vSOV137A .75 IR5265683271 400 SC 1.5 1.3 H

(' 1T48w50V1378 .75 HR5265683271 600 SC 1.5 1.3 H _

~~

QUALIFICATION HILESTONES NOTES REVISION 3 -JULY 1982 A REEVALUATICH CotPLETE 1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE' 5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG- 5 ) FOR OPERATOR LOAOS < OR = 3 6'S

('i C =S/H REC 0ftfENDATION TO LILCO D =0UAL DOC RECEIVED

2. m = DC HOTOR. ALL OTHERS ARE AC
3. CL 1 VALVES < OR = 1 IN. ARE HORIZONTAL Att VERTICAL (FAULTED)
6. IF OtLY ONE LOAD IS GIVEN FOR E=HARDHARE H00IFICATION REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR. IT IS THE HAXIHUN 7 F = QUAL DOC APVD & FILED 4. 2/1 = 2 IN. CLASS 1 i

G =SQRT PAPER C0tPLETE -

H = COPIES OF DOC TO DISTRIBUTION (1

e SHOREHAtt UNIT 1 RBPit LIST STONE & HEBSTER EttGIttEERItG CORPORATION

' JOB HUlIER 11600 3-SDRT Rt24 D?.TE 07/22/22 RE!.CTOR BUILDIP3 CATEGORY I PIPE HOUNTED EQUIPitEtiT RUN TIHE 14.20.22 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (326 ITEttS) PAGE 10 8 5 7 8 i 1 2 3 4 OPER LOAD-G'S OPERATOR 4 QUAL STATUS ItARH PIPE QUAL SPEC LOC.

HUIEER SIZE REPT NO. HOR VER SUPPLIER HODEL tio. YOHE OPER 1293sFCV011A .25 601 SC 1.5 1.3 B _

IZ93aFCV0118 .25 601 SC 1.5 1.3 8 _

1Z93aPCV010A .25 601 SC 1.5 1.3 8 1Z93*PCV0108 .25 601 SC 1.5 1.3 t ,s B _

1821stDV035A 20/1 20-1500GLO9 88AD SC 9.8 2.4 LIllITOROUE stb-1-4 0 H H IB21=110V035B 20/1 20-1500GLO9 C8AD SC 7.5 3.5 LIMITORQUE SPE-1-40 H H 1E11stf0V031A 20 E5836 1.2 88AD SC 7.6 1.1 LIMITORQUd stb-0-40 H H IE11s!OV031B 20 E5836-1.2 88AD SC 6.0 .5 LIMITORQUE stb-0-40 H b IE11all0V031C 20 E5836-1.2 H

l 88AD SC 5.3 .5 LIMITORQUE stb-0-40 N H IE11=10V031D 20 E5836-1.2 88AD SC 5.8 .5 LIMITORQUE stb-0-40 H H

(' IE11alCV032A 20 E5836-1.2 88AD SC 4.1 1.4 LIllITORQUE Ste-0-40 H H IE11mt0V032B 20 E5836-1.2 88AD SC 4.4 7.2 LIttITORQUE $1B-0-40 H h IE11=tt0V032C 20 E5834-1.2 H

88AD SC 4.1 5.8 LIMITORQUE stb-0-40 H H IE11m!OV0320 20 E5836-1.2 88AD SC 5.2 6.5 n LIHITORQUE 588-0-40 H H IE11mlOV034A 18 18-3004 88AD SC 1.0 1.0 LIMITORQUE Ste-3-150 H H IE11=tf0V034B 18 18-300A

( IE11at10V036A 24 E5836-19 88AD 88AD SC SC 1.5 1.9 3.2 2.9 LIHITORQUE LIMITORQUE stb-3-150 St B-4-200 H

H H

H IE11=HOV0368 24 E5836-19 88AD SC 6.9 2.2

(-. LIMITORQUE Sim-4-200 H H IE11mHOV037A 24/1 2422900GT07 88AD SC 3.7 5.6 LIllITORQUE 58-4-200 H H QUALIFICATION IIILEST0 ties NOTES REVISIDH 3 -JULY 1982 C ,

A = REEVALUATION C0t!PLETE 1. CL 2 AFB 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG- 5 ) FOR OPERATOR LOADS < OR = 3 6'S C $/H REC 0ftlENDATION TO LILCO 2. n a DC HDTOR, ALL OTHERS ARE AC HORIZOHTAL AtO VERTICAltFAULTED)  !

D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IH. ARE 6. IF Ott.Y ONE LOAO IS GIVEN FOR E=HARDllARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR. IT IS THE HAXIIIUH I F =0UAL DOC APVD & FILED 4. 2/1 a 2 IH. CLASS 1

(~ ; G =SQRT PAPER C0t1PLETE ~

H = COPIES OF DOC TO DISTRIBUTION

SHOREllAH UNIT 1 EBPtf LIST f tHE & HEISTER EllGINEE2ING CORPORATI0tt RUN DATE 07/22/82 JOB tA3EE2 11400 3-50RT REACTL1 BUILDIt3 CATEGORY I PIPE HOUNTED EQUIPitENT pun TIlfE 14.20.22 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL (324 ITEttS) Pain 11 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 4 QUAL STATUS HARM PIPE QUAL SPEC LOC. {

HUtBER SIZE REPT 180 . HOR VER SUPPLIER tt0 DEL NO. YCHE OPER 1E11aHOV0378 24/1 2422900GT07 88AD SC 4.3 5.1 LIMITORQUE $8-4-200 H H 1E11stOV038A 10 E5834-20 88AD SC 5.8 1.3 LIHITORQUE Ste-2-40 H H g- x IE11alOV0388 10 E5834-20 88AD SC 4.3 1.5 LIMITORQUE SIB-2-40 H H IE11stf0Y042A 14 E5834-4 88A0 SC 3.2 4.1 LIMITORQUE SHB-3-80 H p - H IE11stOV0428 14 E5834-4 88AD SC 4.0 3.9 LIMITORQUE Ste-3-80 H H IE11mHOV047 20/1 20900-GT04 88AD PC 4.9 3.3 LIMITORQUE 58-2-40 N H b" IE11mf0V048 20/1 20900-GT04 88AD SC 4.4 3.8 LIMITORQUE 58-2-40 m H H IE21mit0V031A 14 E5834-7 88AD SC 3.4 2.5 LIMITORQUE Ste-000-5 H H

(~

1E21stOV0318 14 E5834-7 88AD SC 3.5 .4 LIMITORQUE Ste-000 5 H H 1

i 1E21stf0V035A 10 10-300GL 88AD SC 1.3 2.7 LIMITORQUE Ste-1-40 H H

( IE21stOV035B 10 10-300GL 88AD SC 1.3 2.7 L1HITORQUE Ste-1-40 N H l

IE41mit0V035 14/1 14900-GT05 88AD SC 7.3 3.3 LIHITORQUE SIB-3-100 m H H l

l IB21eHOV031 3/1 SR-4040 88V PC 2.4 1.1 LIMITORQUE Ste-00-10 H H 1821stt0V032 3/1 SR-4040 88V SC 3.2 1.3 LIMITORQUE Ste-000-5

  • H H b 1821mit0V034 3 SR-4040 88V SC 1.2 1.4 l

LIHITORQUE Ste-00-7.5 H H 1E11=ll0V033A 14 SR-4244 88V SC 3.4 1.7 LIMITOROUE S15-1-40 N H IE11=HOV0338 14 SR-4244 88V SC 4.2 2.4 LIMITORQUE Ste-1-40 H H l 1E11el10V035A le SR-4244 88V SC 2.3 1.8 LIMITORQUE Ste-1-40 H H 1E11=lI0V0358 14 SR-4243 88V SC 3.0 4.0 LIHITORQUE stb-1-40 H H

~

QUALIFICATION HILESTONES NOTES REVISIOff 3 -JULY 1982 k

A =ftEEVALUATION C0tPLETE 1. CL 2 afb 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATION VALID 8 : REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG. 5 i FOR OPERATOR LOA 05 < OR = 3 G'S *

{' C zS/H REC 0f ttEPOATION TO LILCO 2. e a DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AND VERTICAltFAtLTED) 1 0 =0UAL DOC RECEIVED 3. CL 1 VALVLS < OR = 1 IN. ARE 4. IF OtLY ONE LOAD IS GIVEN FOR E=HARDHARE lODIFICATION REQ'D FLOOR-HOLNTED (ElfTG-5) THE OPERATOR, IT IS THE HAXIHUM I F =00AL DOC APVD & FILED 4. 2/1 = 2 IN. CLASS 1

" G =SQRT PAPER C0tPLETE 1 H = COPIES OF DOC TO DISTRIBUTION

t Sil0REHAtt UNIT 1 RBPH LIST STONE 1 HEBSTER Et:3INEERING CORPORATION RUN DATE 07/22/82 JC3 NUtZE3 11600 3-50RT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPttENT RUN TIttE 14.20.22 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATI0tt LEVEL (326 ITEtts) PAGE 12 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 I

QUAL STATUS ttARM PIPE QUAL SPEC LOC.

, HUHBER SIZE REPT PfD. HOR VER SUPPLIER HODEL NO. YOKE OPER IE11st0V039A 10 SR-6082 88V SC 10.8 1.2 LIHITORQUE Ste-G-25 8 F 1E11mit0V0398 10 SR-6082 88V SC 4.2 5.4 LIHITORQUE stb-0-25 H H i

1E11st10V040A 16 SR-6266 88V SC 9.3 7.3 LIHITORQUE stb-1-60 H H 1E11olmV0408 16 SR-6264 88V SC 9.0 4.0 LIMITORQUE SIB-1-60 N H

(

IE11mit0V041A 6 SR-6177 88V SC 5.8 2.3 LIHITORQUE stb-00-15 H H IE11stOV041B 6 SR-6177 88V SC 13.8 7.2 LIllITORQUE stb-00-15 B F l l b ^

IE11st0V043A 4 l l SR-6180 88V SC 1.2 .4 LIMITORQUE stb-00-15 H H l i

1E11stOV043B 4 SR-4180 88V SC 1.6 1.0 LIllITORQUE SIB-00-15 H H )

('

IE11et0V044A 4 SR-6180 88V SC 1.6 .6 LIMITORQUE 585-00-15 H H 1E11stOV044B 4 SR-6180 88V SC 2.4 1.8 LIMITORQUE stb-00-15 H H t

IE11stOV045A 4 SR-6180 88V SC 1.4 1.1 LIMITORQUE 585-000-5 H H IE11=tt0V045B 4 SR-4180 88V SC 2.8 2.2 LIttITORQUE 582-000-5 H H

(_

IE11=tf0V049 10 SR-6260 88V SC 1.9 3.0 LIMITORQUE Ste-2-80 G G 1E11mit0V050 20 SR-6270 88V 9.9 4.5

(' IE11mHOV051 4 SR-6180 88V SC SC 1.5 1.5 LIHITORQUE LIMITORQUE stb-2-60 SIB-00-7 1/2 m 8

H F

H IE11stIOV052 4 SR-6180 88V SC 2.0 1.3 LIlf1 TORQUE SIB-00-10 H H 1

1E11alI0V053 4 SR-6068 88V SC 2.4 2.4 LIMITORQUE Ste-00-10 m H H 1E11mtIOV054 4/1 SR-6068 88V F;; 3.1 2.9 LIMITORQUE stb-00-15 H H

e. 1E21stOV033A 10/1 SR-6259 88V SC 5.9 4.4 LIMITORQUE $12-2-80 G G

~

QUALIFICATION HILESTONES NOTES REVISIDH 3 -JULY 1982 A = REEVALUATION C0tFLETE 1. CL 2 APO 3 VALVES < OR = 2 IM. ARE 5. PRESErlT QUALIFICATION VALID 8 = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOENTED E EHTG- 5 ) FOR OPERATOR LOADS < OR = 3 G'S

(~; C S/H REcolttEtEATIDH TO LILCO 2. m = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AfD VERTICALIFAULTEDI D =CUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IM. ARE 6. IF Ott.Y ONE LOAD IS GIVEN FOR E=HAR0 HARE tODIFICATION REQ'D FLOOR-HOUNTED iEttTG-5) THE OPERATOR IT IS THE HAXIIIUH T F = QUAL DOC APVD & FILED 4. 2/1 = 2 IM. CLASS 1 I G =SQRT PAPER CotFLETE N = COPIES OF DOC TO DISTRIBUTION

SHOREHAll UtIIT 1 RBPH LIST STONE & HEBSTE3 EftGINEERItG CORPOR*.TI0tl RUN OATE 07/22/82 f JOB HUl'ER 11600 3-SORT LEACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPitENT RUN TIttE 1L 20.22 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATI0ff LEVEL (326 ITE:33 PAGE 13 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 4 QUAL STATUS IIARH PIPE QUAL SPEC LOC.

NUISER SIZE REP 7 PC. HOR VER SUPPLIER BODEL PC.

(, YOHE OPER IE21stDV033B 10/1 SR-6259 88V SC 5.9 4.4 LIMITORQUE S15-2-80 G G IE21=If0V034A 3 SR-6183 88V SC 1.6 .8 LIttITORQUE stb-000-5 H H

(..'

l 1E21mif0V0348 3 SR--8183 88V SC 1.2 .6 LIMITORQUE stb-000-5 H H l

1E41mit0V031 16 SR-6266 88V SC 10.4 2.4 LIMITORQUE S15-0-25 w F F t

1E41=HOV032 16 SR-6266 88V SC 4.5 1.3 LIMITORQUE stb-0-25 m H H 1 I

1E41stOV034 14 SR-6267 88V SC 7.7 2.4 LIHITORQUE SIB-2-60 m H H l

1E41=lIOV036 4 SR-6068 88V SC 3.1 1.3 LIttITORQUE stb-00-10 m H H IE41stmVO37 8 SR-6349 88V SC 2.7 .9 LIMITORQUE stb-1-25 m H H k

IE41eHOV038 10 SR-6262 88V SC 2.8 1.5 LIllITORQUE 588-1-40 m H H IE41stOV041 10/1 SR-6259 88V PC 4.8 2.0 LIMITORQUE S18-3-80 G G 1E41stt0V042 10/1 SR-6264 88V SC 2.4 .8 LIMITORQUE SIB-1-60 m H H IE41st0V043 10 SR-6262 88V SC .7 LIttITORQUE

(* IE41stmV044

.5 stb-1-60 m H H 18 SR-6270 88V SC 2.3 2.4 LIMITORQUE stb-0-15 e H H IE51st0V031 6 SR-6177 88V SC 7.4 3.9 LIMITORQUE stb-00-5 m H H

( 1E51stmV032 6 SR-6177 88V SC 4.4 2.1 LIMITORQUE 5t5-00-5 m H H 1E51stDV034 4 SR-6068 88V SC 1.4 3.3 LIMITORQUE Ste-00-10 m H H IE51alOV035 6/1 SR-6574 88V SC 6.4 5.2 LIHITORQUE SHB-00-25 m F F 1E51mlOV037 4 SR-6068 88V SC 2.2 .9 LIMITORQUE sib-00-30 m H H h IE51=lt0V041 3/1 SR-6060 88V PC 2.5 2.1 LIMITORQUE stb-00-10 H H

~

QUALIFICATION HILESTONES teTES REVISIDH 3 -JULY 1982 A = REEVALUATION COlFLETE l

1. CL 2 Are 3 VALVES < OR z 2 IN. ARE 5. PRESEtlT QUALIFICATION VALID l B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (ENTG- 5 I FOR OPERATOR LOADS < OR = 3 G'S

(~1 C =S/H REColofEtCATION TO LILCO 2. m = DC HOTOR. ALL OTHERS ARE AC HORIZCf4TAL AfID VERTICALIFAULTEDI D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IH. ARE- 4. IF OtLY Ot4E LOAD IS GIVEN FOR

~ E=HARDHARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-53 THE OPERATOR. IT IS THE HAXIltUH F = QUAL DOC APVD & FILED 4. 2/1 a 2 IN. CLASS 1 G =SQRT PAPER C0tFLETE l

H = COPIES OF DOC TO DISTRIBUTION f

oO

/

SHOREHAll UNIT 1 REPH LIST STONE 1 HEBSTE2 EtGINEERItG CORPORATION f JCB tlUIEE3 11600 CUN DATE 07/22/82 3-SORT REACTOR BUILDIt3 CATEGORY I PIPE tt0VNTED EQUIPItENT LILCO DOCl<ET 50-322 RUN TIllE 14.20.22 ACTIVE BOP QUALIFICATION LEVEL (326 ITEttS) PAGE 14 5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ItARM PIPE QUAL SPEC LOC.

PluttDER SIZE REPT fB. HOR VER SUPPLIER lt0 DEL fB. YOliE OPER 1E51mit0V042 3/1 SR-6060 88V SC 4.8 1.2 LIllITOPOUE stb-00-7 1/2 m H H 1E51mHOV043 3 SR-6060 88V SC 1.2 .4 LIMITORQUE stb-00-7 1/2 m H H IE51mit0V045 8 SR-6078 88V SC 4.4 3.6 LIHITORQUE SIB-000-5 m H H IG11mit0V246 4 SR-6180 88V SC 4.3 2.7 LIHITORQUE f

stb-000-5 H H 1G11mit0V247 4 SR-6180 88V SC 3.6 5.9 LIttITORQUE St B-000-5 H H 1G11m!OV248 3 SR-6183 88V SC 1.7 1.3 LIllITORQUE n stb-000-5 H H IG11stIOV249 3 SR-6183 88V SC 2.5 1.2 LIttITORQUE SIB-000-5 H H IG11m!OV639 3 SR-6477 88V SC .6 .5 LIMITORQUE stb-000-5

' H H

(

IG33a10V030A 4/1 SR-6068 88V PC 2.7 3.2 LIMITORQUE St B-00-15 H H 1G33=tt0V0308 4/1 SR-6068 88V PC 2.6 4.1 LIHITORQUE SIB-00-15 H H IG33mt0V031 6/1 SR-6181 88V PC 1.9 2.7 LIMITORQUE Ste-0-40 H H

, IG33*It0V032 4/1 SR-6068 88V PC 4.9 3.1 LIHITORQUE stb-00-10 H H C IG33mt0V033 6/1 SR-6181 88V PC 5.0 .3 LIIIITORQUE Ste-00-25 H H IG33atIOV034 6/1 SR-6181 88V SC 5.7 3.2 LIMITORQUE stb-00-15

  • H i,, H 1G33=fl0V035 4 SR-6353 88V SC 1.8 .8 LIMITORQUE Ste-0-15 H H IG33=tt0V036 4 SR-6353 88V SC .9 .5 LIllITORQUE Ste-0-15 H H C' '

IG33=lt0V037 4 SR-6353 88V SC .7 .8 LIMITORQUE SIB-0-15 H H 1G33stt0V038 4 SR-6068 88V SC .7 .7 LIMITORQUE stb-00-15 H H i

1G33att0V039 4 SR-6068 88V SC .6 .6 LIHITORQUE stb-00-15 H H i

~

QUALIFICATION llILESTONES NOTES REVISION 3 -JULY 1982 k.

A = REEVALUATION ColFLETE 1. CL 2 AFB 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG- 5 ) FOR OPERATOR LOA 05 < OR = 3 G'S I.

)

C =S/H REC 0f 0tENDATION TO LILCO 2. * = DC IETOR. All. OTHERS ARE AC HORIZONTAL AND VERTICAltFAULTEDI l D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 6. IF OtLY ONE LOAD IS GIVEH FOR

~ E=HARDilARE IIODIFICATION REQ'D FLOOR-HOUNTED (EHTG-5) THE OPERATOR. IT IS THE HAXIIIUH F = QUAL DOC APVD E FILED 4. 2/1 = 2 IN. CLASS 1 G =SQRT PAPER C0ftPLETE H = COPIES OF DOC TO DISTRIBUTION i

l l

SHOREHAH UNIT 1 KBPH LIST STONE & HEBSTE3 Et;IllEERIffG CORPORI. TION I, JOB tlUl".E2 11600 RUN OATE 07/22/82 3-SORT EEACTOR BUILWlHG CATEGORY I PIPE HOUNTED EQUIPHEffT LILCO DOCHET 50-322 ACTIVE RUN TIllE 14.20.22 BOP QUALIFICATION LEVEL (324 ITEllS) PAGE 15 s

5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ltARM PIPE QUAL SPEC LOC.

NUIEER SIZE REPT NO. HOR VER

, SUPPLIER HODEL HO. YONE OPER IG33mtCV040 4 SR-6353 88V SC 1.1 1.4 LIHITORQUE SIB-0-15 H H 1G33=lf0V041 6/1 SR-6574 88V SC 5.1 3.9 LIMITORQUE Ste-1-25 H H f

IG41mlOV033A 6 SR-6177 88V SC 1.5 1.5 LIMITORQUE Ste-000-5 H H IG41=lOV033B 4 SR-6177 88V SC

( 1.0 1.0 LIMITORQUE Ste-000-5 N H t IG41mlOV034A 10 SR-6082 88V SC 5.8 1.0 LIMITORQUE stb-0-7 1/2 H H IG41stOV034B 10 SR-6082 88V SC 3.4 .8 LIMITORQUE SIB-0-7 1/2 0 1P42m10V031A 8 SR-6184 H H 88V SC 1.7 .3 LIMITORQUE Ste-000-5 H H IP42stf07031B 8 SR-4184 88V SC 1.8 .5 LIMITORQUE

(,

Ste-000-5 H H IP42 mil 0V032A 8 SR-6186 88V SC .6 .5 LIMITORQUE SIB-000-5 H H IP42mif0V0328 8 SR-6184 88V SC .6 .6

(

LIMITORQUE Ste-000-5 H H IP42mIOV033A 6 SR-4199 88V SC 1.0

.6 LIMITORQUE SHB-000-5 G G IP42=l10V033B 4 SR-6199 88V SC .7 1.0 LIMITORQUE Sim-000-5 G G IP42mtCV034A 4 SR-6199 88V SC 1.3 1.1 LIMITORQUE stb-000-5 S G IP42 mil 0V034B 4 SR-6199 88V SC 1.2 1.1 LIMITORQUE SFB-000-5 G G

(

IP42mtf0V035 4 SR-6180 88V SC 4.4 3.8 LIMITORQUE S15-000-5 H H IP42mit0V036 4 SR-6180 88V SC 4.4 2.3

, LIMITORQUE stb-000-5 H H IP42ml10V041A 14 SR-6265 88V SC 2.6 2.4 LIMITORQUE stb-0-25 H H IP42mHOV0418 14 SR-6265 88V SC 2.1 2.0 LIMITORQUE S12-0-25 O 1P42mHOV042A 14 H H SR-6265 88V SC 1.4 2.7 LIMITORQUE SFB-0-25 H H

~

QUALIFICATI0tl HILEST0ffES NOTES REVISICH 3 -JULY 1982 A mREEVALUATION C0tPLETE 1. CL 2 AND 3 VALVES < OR = 2 IH. ARE 5. PRESEffT QUALIFICATI0tl VALID B REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG- 5 ) FOR OPERATOR LOADS < OR = 3 G'S

(~~ C :S/H REC 0lltfENDATION TO LILCO 2. m = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AtB VERTICALIFAULTEDI D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 4. IF OPE.Y ONE LOAD IS GIVEN FOR

, _ E=HARDHARE If00IFICATION REQ'O FLOOR-HOUNTED (EllTG-53 THE OPERATOR. IT IS THE HAXIHUlf

- F = QUAL DOC APVD & FILED 4. 2/1 = 2 IH. CLASS 1

(' '

G =SQRT PAPER ColPLETE H : COPIES OF DOC TO DISTRIBUTION

  • Q _ _ _ _ ____ _

SHOREHAH UNIT 1 RBPit LIST STONE & HEBSTER ENGIllEERItG CORPORATION JOB flUr1BER 11600 RUll OATE 07/22/82 3-50RT REACTOR BUILDItG COTEGORY I PIPE HOUNTED EQUIPHEHT LILCO 00CHET 50-322 RUN TIHE 14.20.22 ACTIVE BOP QUALIFICATI0H LEVEL (326 ITEllSi PAGE 16 O

5 7 8 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS ftARH PIPE QUAL SPEC LOC.

ItUtBER SIZE REPT NO. HOR VER SUPPLIER f'T IBO&L NO. YOKE OPER IP42 mil 0V002B 14 SR-6265 88V SC 1.6 2.2 LIlfITORQUE stb-0-25 H H IP42=ff0V043A 8 SR-4186 88V SC 1.1 .4 LIHITORQUE SIB-0C0-5 H H

(..

IP42mif0V043B 8 SR-6186 88V SC 3.0 .6 LIMITORQUE SIB-000-5 H H IP42 mil 0V044A 8 SR-6186 88V SC 1.0 .6 LIlfITORQUE stb-000-5 H H IP42ett0V044B 8 SR-6186 88V SC 2.9 1.4 LIllITORQUE SIB-000-5 H H IP42mit0V047 4 SR-6100 88V SC 3.7 4.2 LIHITORQUE p stb-000-5 H H 1P42mif0V048 4 SR-4180 OSV SC 4.0 3.1 LIMITORQUE stb-000-5 H H IP42mit0V147 4 SR-6180 88V PC 4.3 .9 LIttITORQUE stb-000-5

. H H IP42aff0V148 4 SR-6180 88V PC 4.2 1.0 LIlf1 TORQUE stb-000-5 H H IP42mlIOV231 4 SR-6180 88V SC 1.0 .8 LIHITORQUE stb-000-5 t H H IP42mif0V232 3 SR-4183 88V SC 3.5 7.1 LIHITORQUE stb-000-5 H H IP42mit0V233 3 SR-6183 88V SC 4.4 9.8 LIMITORQUE stb-000-5 H H b' IP42=lI0V234 3 SR-6183 88V SC 5.4 9.5 LIMITORQUE stb-000-5 H H IP42ml10V235 3 SR-6183 88V SC 5.9 7.9 LIHITORQUE SHB-000-5 I

H H IP42mit0V236 4 SR-6180 88V SC 4.4 3.6 LIHITORQUE stb-000-5 H H IP42*tt0V237 3 SR-4183 88V SC 4.0 2.5 LIHITORQUE stb-000-5 H H Q'l IP42attOV238 3 SR-6183 88V SC 4.5 1.6 LIHITORQUE SIB-000-5 H H IP42ml10V239 3 SR-6183 88V SC 7.6 2.2 lit 1ITORQUE Ste-000-5 H H IP42mit0V240 3 SR-6183 88V SC 3.8 1.7 LIMITORQUE SIB-000-5 H H

~

QUALIFICATION HILESTONES NOTES REVISIDH 3 -JULY 1982 h

A = REEVALUATION C0!FLETE 1. CL 2 AFB 3 VALVES < OR = 2 IN. ARE 5. PRESENT QUALIFICATI0H VALIO B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EllTG- 5 i FOR OPERATOR LOADS < OR = 3 G'S i

( C =S/H REC 0fRIENDATION TO LILCO O = QUAL DOC RECEIVED

2. m = OC HOTOR. ALL OTHERS ARE AC HORIZONTAL AIB VERTICAL (FAULTEDI
3. CL 1 VALVES < OR = 1 IH. ARE 6. IF ONLY OtIE LOAD IS GIVEit FOR

~ E=HAR0 HARE It001FICATION REQ'D FLOOR-HOUNTED EEffTG-53 THE OPERATOR. IT IS THE ttAXIHUti F = QUAL DOC APVD & FILED 4. 2/1 = 2 IH. CLASS 1

(

G =SQRT PAPER COlFLETE H = COPIES OF DOC TO DISTRIBUTIDH

SHOREHAH tRIIT 1 CBPH LIST STotlE & HEBSTER EfEIfiEERItG CORPORATION JOB tlUI'4E2 11600 RUN DATE 07/22/82 3-30RT REACTOR BUILDING CATEGORY I PIPE IIOUNTED EQUIPtfENT RUN TIllE 14.20.22 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL (326 ITENSI PAGE 17 l

l 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS i itARH PIPE QUAL SPEC LOC.

NUtBER SIZE REPT tm. HOR VER

<T SUPPLIER If00EL to. YONE OPER IT48etOV031A 6 SR-6177 88V PC 2.9 1.3 LIlfITORQUE Sts-00-5 H H IT48 mil 0V031B 6 SR-6177 88V PC 4.4 3.4 n LIMITORQUE stb-00-5 H H IT48stmV032A 6 SR-6177 88V PC 3.7 2.7 LIMITORQUE SIB-00-7 1/2 H H IT48 elf 0V032B 6 SR-4177 88V PC 5.4 4.1

<, LI:tITORQUE stb-00-7 1/2 H H IT40stOV033A 6 SR-6177 88V SC 4.2 1.5 LIMITORQUE Ste-00-5 H H IT48elmV033B 6 SR-4177 88V SC 4.0 1.8 LIMITORQUE stb-00-5 H H 1T48etOV034A 6 SR-6177 88V SC 3.7 1.8 LIMITORQUE stb-00-7 1/2 H H IT48mit0V0348 6 SR-6177 88V SC 3.2 1.5 LIMITORQUE

, stb-00-7 1/2 H H IT48mlOV035A 4 SR-6180 88V SC 4.2 2.8 LIMITORQUE stb-000-5 H H IT48mit0V035B 4 SR-6180 88V SC 2.1 4.2 LIttITORQUE SIB-000-5 H H b~

IT48mif0V037A 6 SR-6177 88V SC 3.9 3.5 LIHITORQUE SIB-00-7 1/2 H H 1T48stOV0378 6 SR-6177 88V SC 2.7 2.4 LIllITORQUE stb-00-7 1/2 7 H H 1T48mit0V0384 4 SR-6180 88V SC 4.1 2.0 LIMITORQUE stb-000-5 H H IT48efl0V0388 4 SR-6180 88V SC 4.2 1.7 LIffITORQUE stb-800-5 N H O IT48almV040A 6 SR-6177 88V SC 4.1 1.1 LIMITORQUE stb-00-7 1/2 H H IT48=110V040B 6 SR-6177 88V SC 3.2 1.8 LIMITOROJE f stb-00-7 1/2 H H IT48mif0V041 4 SR-6180 88V SC 1.4 .9 LIMITORQUE stb-000-5 H H IT48stl0V042 4 SR-6180 88V SC .9 2.0 LIH1 TORQUE SIB-G00-5 H H

(.. '

1T48mt0V043A 4 SR-6180 88V SC 2.9 2.5 LIMITORQUE stb-000-5 H H

~

QUALIFICATION HILESTONES NOTES REVISION 3 -JULY 1982

([

A = REEVALUATION ColFLETE 1. CL 2 AFB 3 VALVES < OR = 2 IH. ARE 5. PRESENT QUALIFICATI0tl VALIO B = REQUEST FOR QUAL OR 8IO ISSUED FLOOR-190UtITED (EllTG- 5 i FOR OPERATOR LOADS < OR = 3 G'S

('~ C =S/H REcol0fENDATION TO LILCO 2. a DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AfD VERTICAL (FAULTED)

D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IN. ARE 6. IF OtLY CHE LOAD IS GIVEN FOR

~ E=HAR0 HARE HODIFICATION REQ'D ILOOR-HOUNTED (EHTG-5) THE OPERATOR. IT IS THE HAXIHUH

- F = QUAL DOC APVD & FILED 4. 2/1 a 2 IN. CLASS 1 G =SQRT PAPER COIPLETE H = COPIES OF DOC 10 DISTRIBUTIOH 4

I

n . - . - . . . - _ _ . - - --. ._.

SHOREHAH UNIT 1 RBPH LIST STotlE & HESSTEC C;4INEERIt4G CORPORATION I JOB HLn 2 R 11600 RUtl (CATE 07/22/82 3-30RT CEACTOR BUILDING CATEGORY I PIPE If00NTED EQUIPitENT LILCO 00CHET 50-322 RUN TIHE 10.20.22 ACTIVE BOP QUALIFICATI0tl LEVEL (324 ITEHS) PAGE 18

/

5 T S 1 2 3 4 OPER LOAD-G'S OPERATOR 6 QUAL STATUS IIARH PIPE QUAL SPEC LOC.

tiU!BER SIZE REPT HO. HOR VER SUFPLIER HDDEL F10.

(

YONE OPER IT48mit0V0438 4 SR-6180 88V SC 4.8 3.0 LIMITORQUE Ste-000-5 H H IT48att0V044A 4 SR-6180 88V SC 4.0 1.9 LIttITORQUE SHB-000-5 H H IT48mif0V0448 4 SR-6180 88V SC 4.8 1.9 LIHITORQUE SIB-000-5 H H

(

O s

(.

i 1

( .

(

O

(

~

QUALIFICATI0H HILEST0t1ES NOTES REVISIDH 3 -JULY 1982 C

A =REEVALUATIDH C0tPLETE 1. CL 2 Ate 3 VALVES < OR = 2 IH. ARE ' 5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUlfTED (EllTG- 5 I FOR OPERATOR LOADS < OR = 3 G'S-(' C =S/H REcol0lEPOATION TO LILCO 2. * = DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AfD VERTICAltFAULTEDI D = QUAL DOC RECEIVED 3. CL 1 VALVES < OR = 1 IH. ARE 6. IF OtLY Ot4E LOAD IS GIVEN FOR '

E=HARDHARE HODIFICATION REQ'D FLOOR-HOUNTED iENTG-53 THE OPERATOR IT IS THE HAXIIIUM I F = QUAL DOC APVD & FILED 4. 2/1 = 2 IH CLASS 1 S =SQRT PAPER C0tFLETE H = COPIES OF DOC TO DISTRIBUTION

SHOREHAH UtlIT 1 H LIST ST0 TIE & HEISTE% EtlGINEERING CORPORATION JOB llulBER 11600 RUti DATE 07/22/02

, 3-50RT HISCELLAffEOUS CATEGORY I EQUIPitErlT RUti TIffE 14.19.05 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL i 17 ITEMS) PAGE 1 .

ItARN EQUIPitENT SPEC DIV. BLDG AVAIL QUAL QUAL TYPE SAFC QUAL NUMBER DES 2RIPTION F10. RESP VEtOOR ELEV INSP REPT llETH FREQ HTitG SitTDil STATUS IP41mP-003 SERVICE HATER PUtFS 057 PD BINGHAH-HILL SH021 YES 230629 SA 28 F4 CS.HS H IP41=S-001 SERVICE HATER STRAIT 4ER 081 PD RP ADAllS CD SH026 YES N07503 DA 17 F4 CS,HS H 1R43 NTH-132 FUEL UIL STORAGE 114 PD BUFFALO TAtlH YD020 YES t#ftBI-22 SA 14 F3 CS H p 1R24allCC1110 400 V HOTOR CONT CENTE 115 ED SQUARE D CO SH021 YES 108-1.01L2 ftBT 4 F CS.HS H 1R24*tfCC1120 480 V ff0 TOR C0 tit CENTE 115 ED SQUARE D CD SH021 YES 108-1.01L2 IfBT 4 F CS.llS H

,, IP41mPriL-FX1 FD AUX RELAY CABINET 125 CD RELIANCE SH023 YES 99AX400708 SA/ SAT 33+ F CS.HS H IP41ml10V031 SERV HATER DIS 197 PD PRATT SM020 YES D-0034-1 SA/ SAT 33+ P4 CSells H IP41=lt0V032 SERV HATER HOR IV 197 PD PRATT SH033 YES D-0034-6 SA/ SAT 33+ P2 CS.HS H IP41=tt0V035 T BELOH SUPLY IV 197 PD PRATT Sil025 YES D-0034-6 SA/ SAT 33+ P2 il H IX41mFil-068 SCRilHELL PUtFHSE SUP 270 PD BUFFALO FORGE SH034 YES 745-11140 SA 26+ F2 CS HS H IX41=1100042 FN-68 OUTDOOR AIR 319 CD pollers SH025 YES 44057-1 ftBT 21 F2 CS.Ils H IX41sttOD043 FN-68 EXHAUST AIR 319 CD P0HERS SH025 YES 44057-1 IBT 21 F2 CS.IIS H IX41mit00044 FN-68 RETURN AIR 319 CD P0HERS Sl1025 YES 44057-1 IBT 21 F2 CS.HS ~ H

g. IX41mTT008 SCRHL PUlFHSE TEllP 319 CD P0HERS SH025 YES 43812-1 IBT 24 F2 il H IC61*PT-011 SVC HTR HDR PRESS 406 CD ROSEHOUNT SH YES 127516 IBT '

60+ F CS.HS F 1R43mP-201 FUEL OIL XFER PU 420 PD CRANE CO YD020 YES IfE572 SA 13 F3 CS H t IR43mP-202 FUEL OIL XFER PU 420 PD CRANE CO YD020 YES HE572 SA 13 F3 CS H C

( CS = COLD SHUT 00llN P = PIPE HOUNTED SBT=SItlGLE FREQUEllCY QUALIFICATION HILEST0 ties REVISI0tt 2 -JUNE 1982 DA :DYtlAlf!C AtlALYSIS PC =PRIltARY CONT. BIAXIAL TESTItIG A = REEVALUATION CCitPLETE F = FLOOR llOUtlTED PL :PEDEST".L SC = SECONDARY CONT. B = REQUEST FOR QUAL OR DID ISSUED NOTE: tiUtIDER Itt HS = HOT STAl;DBY QP = QUALIFIED BY C =S/H REC 0tRIENDATI0tl TO LILCO ' TYPE IITtIG' COLUltri IS ItDT=ltULTI-FREQUENCY PIPING ANALYSIS * = LOCATED ON CONT. D = QUAL DOC RECEIVED QUAtlTITY OF ITEttS.

_ DIAXIAL TESTItlG SA = STATIC ANALYSIS HALL E =HARDHARE IIODIFICATION REQ'D tIST=lfULTI-FREQUEllCY SAT = SINGLE FREQUEttCY N =NEITHER CS OR HS F= QUAL DOC APVD & FILED SINGLE AXIAL TESTING SINGLE AXIAL TESTING G =SQRT PAPER C0ftPLETE H = COPIES OF DOC TO DISTRIBUTIO!I 8R

SHOREHAll UtlIT 1 GE LIST SToriE & HEBSTER EtiGINEERItG CORPORATI0tt JOB IIUIEE2 11600 luti DATE 07/22/82 1-50RT GEllERAL ELECTRIC CATEGORY I EQUIPilENT RUN TIHE 15.31.24 LILCO DOCHET 50-322 ACTIVE NSSS QUALIFICATION LEVELf139 ITEllS) PAGE 1 IIARH EQUIPHEtiT GE BLDG AVAIL QUAL llul1BER QUAL TYPE SAFETY QUAL DESCRIPTI0tl NO. VENDOR ELEV INSP REPT HETH FREQ HTNG FUNC STATUS IB21*A0V081 ISOLATION VALVE-HS B21F022 ROCHHELL SC082 YES tlEDE-24122-2 SA 8 P4 CS.HS G

, ID21mA0V082 ISOLATION VALVE-flS B21F028 ROCHHELL SC082 YES NEDE-24122-2 SA 8 P4 CS.HS G 1821mD-003 CatIDENSItiG CHA!BER 8210002 GE SC080 YES DRF-A00794-11 SA 60+ P HS.CS G g IBtinD-004 C0f0EtISIfG CHAIBERS B210004 GE SC080 YES DRF-A00794-11 SA 60+ P2 HS.CS G 1B21tD-005 C0f 0ENSItG CHA!BERS B210006 GE SC080 YES DRF-A00794-11 SA 60+ P16 HS.CS G 1821.tPS 020 PRESSURE SHITCH B21N015 BARKSDALE SC049 YES DV164CS359 SAT 33+ F4 H D 1821tRV 092 RELIEF VALVE B21F013 TARG ROCH PC099 YES VPF-5485-3-1 IST 60+ P11 CS G 1821mTE 003 TEIFERATURE ELEllEtiT B21N040 ROSEHOLRIT T083 DV159C4520 SAT 100 F H D 1821mTE 043X TEMPERATURE ELEHEHT B21N016 PYC0 T059 DV164C5359 SAT 60+ F4 H D

( IB21mTE 043Y TEIFERATURE ELEHENT B21H010 PYC0 T059 DV145C3004 SAT 60+ F4 H D 1821mTE 059 TElFERATURE ELEllENT B21H014 PYC0 T059 DV145C3224 SAT 60+ F4 H D IB31stl0V031 RECIRC SUCTION VALVE B31F023 AtCHOR SC017 YES 385HA661 s

SA 41 P2 H G 1831til0V032 RECIRC DISCHARGE VALVE B31F031 AtCHOR SC014 YES SA/DA P2 H B

, 1831tP- 001 RECIRC PUlF & il0 TOR B31C001 BJ/GE PC070 YES 206B33C001-HS-1 SA 60+ P2 H G 1831mTE 025 TEIFERATURE ELEllENT B31H023 CROUSE-HI SC DV159C4520 SAT 10 F2 H D 4 1C11mA0V081 HCU DIAPHRAGil VALVE C11F010 6501 SC078 YES SA P CS.HS B 1C11mA0V082 HCU DIAPHRAGil VALVE C11F011 teet SC040 YES SA P CS.HS B g IC11tHCU-01 CRD HYDRA CONT UNIT C11D001 GE SC078 YES 383HA853 HST 2 137 CS.HS G IC11rLS 095 LEVEL SHITCH C11H013 HAGHETROL SC YES DV159C4361 SAT 30+ F8 H D IC11mSOV044 HCU SOLENOID VALVE C11F009 ASCO SC063 P CS.HS B i

_1C41EEV 010 EXPLOSIVE VALVE C41F004 COHAX SC112 YES VPF3394-36-2 SBT 35+ PZ H G CD =COteTROL BLDG P = PIPE HOUNTED SBT=SItGLE FREQUENCY QUALIFICATI0ft HILESTONES REVISION 3 -JULY 1982 CS = COLD SHUT D0681 PC =PRIllARY CONT. BIAXIAL TESTING A = REEVALUATION CotFLETE DA =DYtlAllIC AFIALYSIS PL = PEDESTAL SC =SEC0tOARY CONT.

F = FLOOR ll0UllTED QP = QUALIFIED BY B = REQUEST FOR REQUAL OR BID ISSUED HOTEt flut2ER IN 1 / = LOCATED ON CONT. C =S/H REC 0ftlEtOATION TOLILCO ' TYPE HTNG' COLUHN IS HS = HOT STAtIDBY PIPItG AtiALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEHS.

_l!DT=ltULTI-FREQUEtCY RH =RADHASTE T =HAIN STH. TUtflEL E =HARDHARE HODIFICATION REQ'D

- BIAXIAL TESTIrlG SA = STATIC ANALYSIS H =NEITHER CS OR HS F = QUAL DOC APVD & FILED

ilST=lfULTI-FREQUEICY SAT =SItiGLE FREQUEtCY G =SQRT PAPER COFFLETE SINGLE AXIAL TESTING SIllGLE AXIAL TESTING H = COPIES OF DOC To DISTRIBUTION i

O o __ ____ i__

'i SHOREllAH UNIT 1 GE LIST STONE & HEBSTER ENGINEERING CORPORATION RLM DATE 07/22/82

(' JOB HUIRER 11600 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPHENT LILCO DOCKET 50-322 RUH TIHE 15.31.24 -

ACTIVE NSSS QUALIFICATION LEVEL (139 ITEHS) PAGE 2 IIARN EQUIPHENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL NUtBER DESCRIPTION HO. VEte0R ELEV INSP REPT HETH FREQ HTNG FUNC STATUS v IC41mP-024 STDBY LIQ PUlFAtlTR C41C001 UNION PtAt SC113 YES VPF-5517-2-2 SBT 60+ F2 N G

( IC41rPI 002 PRESSURE IlEICATOR C41R003 ROBT SHAH SC YES DV163C1184 SAT 33+ F H D (,

IC41tPT 002 PRESSURE TRANSIIITTER C41H004 ROSEHOUNT SC YES DV163C1563 SAT 3 F H D

( 1C41u1H-003 SLC STORAGE TAtM C41A001 LAHC0 SC113 YES RAS 42/C41-22 SA 59 F H G (

IC41eTH-150 SLC ACCUHULATORS C41A003 HYDRA CON SC097 YES SA P2 N G t, IC41mTS001A TEtr SHITCH C41N003 HEED INST IC51mTIP-004 TIP VALVE GUIDE T C51J004 GE SC073 YES DRF-A00992-H SAT 40+ F4 N D

( IC61sCE 014 Cote TRANSilITTER C61N008 BALLSBAUG SC043 DV163C1544 SAT 3 F M D d IC61*FT 001 DIFF PRESS XHTR C61N001 ROSEHOUNT SC006 YES DV163C1560 SAT 50 F M D

(, IC61tPtL-RSP REll0TE ntT DN Pte. C41P001 SC063 YES GE SAI-029QA80PA-B MT 14 F N G C IC61rPT 006 PRESS TRANS C61N006 BAILEY SC079 YES DV163C1186 SAT 33+ F H D

( IC71sPS 003 PRESSURE SHITCH C71N003 BARKSDALE SC DV164C5359 SAT 33+ F4 H D 1E11sE-034 RHR HEAT EXCHANGERS E11B001 PERFEX CP SC008 YES DRF E11-1 DA 14 F2 HS.CS S t, IE11mFT 004 DIFF PRESS 30fTR E11N013 ROSEHOUNT SC078 DV143C1560 SAT 50 F M D Q

IE11mFT 004 DIFF PRESS TRANS E11N007 ROSEliotAfT SC078 DV143C1560 SAT 50 F2 N D 1E11 ALT 002 LEVEL XIITR E11N008 BARTON SC024 DV145C3156 SAT 100 F2 H D 1E11aP-014 RHR PUFFS SHOTORS E11C002 BJ/GE SC008 YES DA F4 HS.CS B

(, IE11tPS 134 PRESSURE SHITCH E11H016 BARHSDALE SC008 YES SHIP LOOSE SAT 33+ F4 H D (

IE11tPS 135 PRESSURE SHITCH E11N020 BARHSDALE SC008 YES SHIP LOOSE SAT 33+ F4 N D s 1E11mTE 014 TEHP ELEHENT E11H009 PYC0 SC023 DV145C3224 SAT 40+ F2 H D t

_1E11mTE 015 TElr ELEHENT E11H030 PYC0 SC023 YES DV145C3224 SAT 60+ F2 H D CB =C0tiTROL BLDG P = PIPE fl0UNTED SBTsSINGLE FREQUENCY QUALIFICATION HILESTONES CS = COLD SHUT DOIN REVISICH 3 -JULY 1982 PC PRIHARY CONT. BIAXIAL TESTING A mREEVALUATION ColFLETE DA :DYt4AllIC ANALYSIS PL = PEDESTAL SC =SEC0tmARY CONT. B aREQUEST FOR REQUAL OR BID ISSUED F = FLOOR HOUNTED NOTE 8 NUISER IN QP = QUALIFIED BY / mLOCATED OH CONT. C zS/H REColttEteATION TOLILCO ' TYPE HTNG' COLUlst IS HS = HOT STAtiDBY PIPING ANALYSIS HALL D sQUAL DOC RECEIVED QUANTITY OF ITElts.

_tlDT:HULTI-FREQUENCY RH RADHASTE T =HAIN STH. TtA#iEL E =HARDHARE HODIFICATION REQ'D

- BIAXIAL TESTIt4G SA : STATIC ANALYSIS H =HEITHER CS OR HS F zQUAL DOC APVD & FILED tlST ltulTI-FREQUEt4CY SATsSINGLE FREQUENCY G zSQRT PAPER C0FFLETE SINGLE AXIAL TESTIttG SINGLE AXIAL TESTING H : COPIES OF DOC TO DISTRIBUTION o

- _ - _ _ - _ _ _ - - . . .- . = . . _ _ _ - . . - ._- _- ~ ._ - -

SHOREHAH UNIT 1 GE LIST STONE & HEBSTE3 EtEIt4EERING CORPORATICH JOB hut *iER 11400 RUN D?.TE 07/22/S2 1 1-SORT GENERAL ELECTRIC CATEGORY I EQUIPHENT LILCO 00CHET 50-322 RUN TIME 15.31.24 ACTIVE NSSS QUALIFICATION LEVEL (139 ITEMS) PAGE 3 HARM EQUIPHENT GE BLDG AVAIL QUAL i HUHBER QUAL TYPE SAFETY QUAL DESCRIPTION HO. VENDOR ELEV INSP REPT HETH HTIE FUNC FREQ STATU3 IE21mP-013 CS PUFFS & HOTORS E21C001 BJ/GE SC006 YES DA F2 CS S (f IE21*PISO98 PRESS ItGIC SHITCH E21H010 ROST SHAH SC YES DV143C1185 SAT 33+ F2 N D s 1E21ePS 012 PRESSURE SHITCH E21H008 BARHSDALE SC008 YES SHIP LOOSE SAT 33+ F2 N D y 1E21mPS013 PRESSURE SHITCH E21H009 BARHSOALE SC008 YES SHIP LOOSE SAT 33+ F2 N D .[j' 1E32=BLO-13 OUTBD HSIV LCS BLOHER E32C002 GE SC074 YES VPF3830-14-1 SBT 40+ F2 N G

,( IE32eBLO-14 ItBD HSIV LCS BLOHER E32C001 GE SC074 YES VPF3830-14-1 SBT 40+ F M G IE32aFE037 FLOH HETER E32N004 SAN P4 l(, IE32sHC-053 HSIV LCS HTR E328001 GE SC078 IST IE32xPDT035 DIFF PRESS TRANS E32N059 P4 N B Q

ROSEHOUNT SC YES DV143C1541 SAT 50 F N D (j 1E32tPT 033 GAGE PRESS TRANS E32H055 ROSEHDUNT SC YES DV143C1544 SAT 50 M F D j 1E32xPT 034 ABS PRESS TRANS E32N054 ROSEHOUNT SC YES DV143C1558 SAT 50 F M D j( 1E41tLSO91 LEVEL $ HITCH E41N014 HAGNETROL SC014 YES DV159C4341 SAT 4 F N D 'l IE41tL5092 LEVEL SMITCH E41N015 HAGNETROL SC027 DV159C4294 SAT F2 1 N D l( 1E41tLSO93A LEVEL SHITCH E41H002 NAGNETROL YARD YES DV159C4294 SAT 1 F M D 1Eq1tLSO938 LEVEL SHITCH E41N003 HAGNETROL YARD YES DV159C4294 SAT 1 F M D 1E41sP-014 HPCI PutFAB00 STER E41C001 PACIFIC P SC008 YES VPF-2740-180-1 DA 23 F N G v 1E41mTE053 TEtFERATURE ELEHENT E41H024 PYC0 SC044 YES DV145C3224 SAT 40+ F2 N D

!(, IE41mTE054 TERFERATL5tE ELEHENT E41H028 PVC0 SCO31 YES DV145C3224 SAT 40+ F2 N D t IE41mTE055 TEIFERATURE ELEHENT E41N029 PYC0 SC017 YES DV145C3224 SAT 40+ F2 N D

,g IE41mTE054 TEIFERATURE ELEMENT E41H030 PYC0 SC075 YES DV145C3224 SAT 40+ FZ H D y

_1E41mTI141 TEtF IFEICATOR E41R002 HEED SC008 YES DV145C3103 SAT 100 F M D i C3 = CONTROL BLDG P : PIPE HOUNTED SBTsSINGLE FREQUENCY QUALIFICATION HILESTONES CS zCOLD SHUT D0684 REVISION 3 -JLA.Y 1982 PC =PRIHARY CONT. BIAXIAL TESTING A zREdVALUATION CotFLETE j DA :DYllAHIC ANALYSIS PL PEDESTAL #

SC zSEC0tSARY CONT. B = REQUEST FOR REQUAL OR BID ISSUED HDTE 4AASER IN ii~ F = FLOOR HOUNTED QP = QUALIFIED BY / = LOCATED ON CONT. C =S/H REcot04EtGATION TOLILCO HS = HOT STANDBY

  • 1YPE NTNG' COLtRet IS
PIPING ANALYSIS HALL D mQUAL DOC RECEIVED QUANTITY OF ITEHS.

i HBT=ltULTI-FREQUENCY ' RH mRADHASTE T =HAIN STN. TIAR4EL E =HARDHARE HODIFICATION REQ'D l

I BIAXIAL TESTIts SA zSTATIC ANALYSIS N NEITHER CS OR HS F aquAL DOC APVD & FILED HST=ttULTI-FREQUFNCY SAT = SINGLE FREQUENCY G =SQRT PAPER COPFLETE l

SINGLE AXIAL TESTIts SINGLE AXIAL TESTIts H COPIES OF DOC TO DISTRIBUTION l

W .h -

SHOREHAH th4IT 1 CE LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 07/22/82

, JOB NUtEER 11400 1-SORT EENERAL ELECTRIC CATEGORY I EQUIPHENT RUN TIHE 15.31.24 LILCO DOCHET 50-322 ACTIVE NSSS QUALIFICATION LEVELt139 ITEHS) PAGE 4 HARN EQUIPHENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL i nut 1BER DESCRIPTION HO. VEtGOR ELEV INSP REPT f

HETH FREQ NTNG FLA4C STATUS 1E41mTU-002 HPCI TURBINE E41C002 TERRY SC008 YES >ST F M B 1 j 1E51aLS091 LEVEL SHITCH E51N010 HAGNETROL SC008 YES DV159C4341 SAT 4 F M D (

IE51mP-015 RCIC PUtr E51C001 BINGHAM SC004 YES SA F HS 8

, IE51mTE052 TEtFERATURE ELEHENT E51H011 PYC0 SC025 YES DV145C3224 SAT 40+ F2 N O y 1E51mTE053 TEtFERATURE ELEHENT E51N022 PYC0 SC031 ,YES DV145C3224 SAT 40+ F2 N D

(, IE51mTE054 TEIFERATURE ELEHENT E51N023 PYC0 SC075 YES DV145C3224 SAT 40+ F2 N D j IE51mTE055 TEIFERATtstE ELEMENT E51N025 PYCO SC044 YES DV145C3224 40+

SAT F4 N D

( 1E51mTE054 TEMPERATURE ELEHEtiT E51N024 PYC0 SC075 YES DV145C3224 40+

IE51mTI141 SAT F4 H D d

THERH0 HETER E51R005 ROST SHAM SC008 DV145C3103 SAT 100 F M D

(; 1E51mTU-005 RCIC TUR8INE E51C002 TERRY SC004 YES VPF3422-79(13-2 SA/HBT 15 6 IF11mTO-005 F HS Q

FUEL PREP NACHINE F11E001 GE SC174 DA F2 N 8

( > 1F11mTO-008 GEN PURPOSE GRAPPLE F11E011 GE SC174 YES DRF139F11E011L SA WA F3 N G 1F13xSL-001 DRYER 4SEP SLING F13E008 CAL PAC SC174 YES DRF F13-9 SA WA F M G

() 1F13mTO-014 HEAD STRONGBACH F13E009 LAHC0 SC174 YES DRF F13-11 SA N/A F M G 1F14mTO-029 C0 tit R0D GRAPPLE F14E002 GE SC174 YES DRF139F14E002M SA WA F M G

( IF15sCRN-009 REFUEL PLTF ASSY F15E003 STERN ROG SC174 YES DRFF00000022 DA WA F M G g IF16mCSH-01 DEF F STRG CONTAIN F14E009 GE SC151 YES 139F14E009N1 DA 1 F8 N G g IF16tRAH-025 POISON CURTAIN F14E015 Bir DA F14 H G 1F16mRAM-09 FUEL RACH(IN VESSL) F14E004 VOTAN SC174 DA F2 14 5 1F16tRAN-10 STRG RACH(CR&DEF Fl F14E004 GE SC137 YES DRF F14-0003 13 DA F3 N G IF16sRAN-11 NEH FUEL STRG RACHS' F1dE007 GE SC151 YES DRF F00-00002 DA WA I F17 N G

~

C3 =C0tlTROL BLDS P = PIPE HOLAITED $8T= SINGLE FREQUENCY QUALIFICATI0H HILESTCHES CS = COLD SHUT 006#4 REVISION 3 -JLA.Y 1982 PC =PRIHARY CONT. BIAXIAL TESTING A mREEVALUATICH CotFLETE

! DA :DYHAHIC ANALYSIS PL : PEDESTAL SC :SEC0tGARY CONT. B

  • REQUEST FOR REQUAL DR BIO ISSUED F = FLOOR HOUNTED NOTE 3 FRASER IN i' QP = QUALIFIED BY /
  • LOCATED ON CONT. C :S/M REcotStEISATION TOLILCO HS = HOT STAT 0BY ' TYPE HTNG' COLIA04 IS PIPING ANALYSIS NALL D = QUAL DOC RECEIVED QUANTITY OF ITENS.

tGT*HULTI-FREQUENCY RH mRADHASTE T HAIN STH. TLRetEL

~. E =HARDNARE NODIFICATION REQ'D

. BIAXIAL TESTING SA x5TATIC ANALYSIS H NEITHER CS OR HS F = QUAL DOC APVD & FILED HSTattulTI-FREQUEHCY SAT

  • SINGLE FREQUENCY G =SQRT PAPER CotFLETE SINGLE AXIAL TESTING SIllGLE AXIAL TESTING (~

H aCOPIES OF DOC TO DISTRIBUTION s

I

SHOREHAll utIT 1 GE LIST ST0llE & HEBSTER EttGIllEERING CORPORATION RUN DATE 07/22/82 JOB HUtBER 11600 1-50RT GEt(ERAL ELECTRIC CATEGORY I EQUIPitENT Rui TIttE 15.31.24 ,

LILCO DOCHET 50-322 ACTIVE ilSSS QUALIFICATION LEVELt139 ITEttS) PAGE 5 ftARH EQUIPl!EtiT GE BLOG AVAIL QUAL QUAL TYPE SAFETY QUAL HutBER DESCRIPTIOtt il0. VEf00R ELEV INSP REPT HETH FREQ HTtG FUNC STATUS 1G33mFT012 DIFF PRESS TRANS G33tIO41 ROSEttouiT SC DV14SC3240 SAT S0 F H D

( 1G33mTE020E TEtFERATURE ELEltEtiT G33N042 CAL ALLOY SC97 YES SHIP LOOSE SAT 10 F H D 1G33mTE071 TEIPERATURE ELEHEt(T G33tt016 NECI SC136 YES DV145C3224 SAT 60+ F6 H D t 1H11mPIL-601 REAC& CORE COOL BB H11P601 GE CB063 YES SAI-029QA80PA-B fBT 14 F HS.CS G s #

1H11mPtL-602 RHCU 1 RECIRC BH H11P602 GE CB063 YES SAI-029QA80PA-B IBT 14 F HS,CS G q, Ill11mPtL-603 REACTOR COtITROL B H11P603 GE CB063 YES SAI-029QA80PA-B IST 14 F HS.CS G t

1H11mPFL-608 PHR RANGE IIEUT CA H11P608 GE CB063 YES tBT F H B IH11mPtL-609 TRIP SYS A RPS VB H11P609 CB063 YES SAI-029QA80PA-B GE IBT 22 Cl F HS.CS G l

l IH11mPtL-611 TRIP SYS B RPS VB H11P611 GE CB063 YES SAI-029QA80PA-B fBT 22 F HS.CS G l

, 1H11mPtL-612 FH & RECIRC IllSTR H11P612 GE CB063 YES SAI-029QA80PA-B fBT 19 F H G vl Ill11mPtL-613 PROCESS INSTR CAB H11P613 GE CB063 YES SAI-029QA80PA-B IBT 14 F HS.CS G

., ; IH11mPIL-614 itSS TEtF LH DET VB H11P614 GE C8063 YES SAI-029QA80PA-B fBT 22 F H G ,

1H11mPtL-617 DIV 1 RHR RELAY VB H11P617 GE CB044 YES SAI-029QA80PA-B fBT 19 F HS,CS G

( 1H11mPtL-618 RHR RELAY VB H11P618 GE CB044 YES SAI-029QA80PA-B fBT 19 F HS.CS G IH11mPtL-620 HPCI RELAY VERT BJ H11P620 GE CB044 YES SAI-029QA80PA-B IBT 14 F H G l, 1H11mPtL-621 IC RELAY VERT BD H11P621 GE CB044 YES SAI-029QA80PA-B IBT 14 F HS.CS G ,

t l

Ill11mPtL-622 ItBD ISO V RELAY VB H11P622 GE CB044 YES SAI-029QA80PA-B IBT 21 F CS G ji 1H11mFIL-623 OUTBD ISO V REL VB H11P623 GE CB044 YES SAI-029QA80PA-B fBT 21 F CS G (

1H11mPtL-626 DIV 1 COR SP REL VB H11P626 GE CB044 YES SAI-029QA80PA-B HBT 14 F CS G IH11mPtL-627 DIV 2 COR SP REL VB H11P627 GE CB044 YES SAI-029QA80PA-B IET 14 F CS G ,

_Ill11mPIL-628 AUTO BLOHDial REL VB H11P628 GE CB044 YES SAI-029QA80PA-B IET 14 F CS G CB =C0tiTROL BLD3 P = PIPE tt0UNTED SBT= SINGLE FRECUENCY QUALIFICATION HILESTONES REVISIDH 3 -JULY 1982 CS = COLD SitUT Doliti PC :PRIttARY COtlT. BIAXIAL TESTItiG A zREEVALUATI0tl COIPLETE DA =DYllAllIC AtlALYSIS PL = PEDESTAL SC =SEC0f0ARY CONT. B sREQUEST FOR CEQUAL OR BID ISSUED tt0TE: NUtBER IN F zFLOOR tt0UNTED QP zQUALIFIED BY / = LOCATED ON C0 tit. C zS/H REC 0f tlENDATIGil TOI-ILCO ' TYPE HTIG' COLuft IS IIS = HOT STATIDBY PIPItG AftALYSIS HALL D zQUAL DOC RECEIVED QUANTITY OF ITEttS.

~

IBT=lfULTI-FREQUEllCY RH mRADHASTE T allAIN STil. TurtlEL E sHARDHARE H00IFICATI0tt REQ'D BIAXIAL TESTIttG SA = STATIC AtlALYSIS tt zilEITHER CS OR HS F = QUAL DOC APVD & FILED llST=lfULTI-FREQUEllCY SAT =SItIGLE FREQUENCY G zSQRT PAPER C0t1PLETE SINGLE AXIAL TESTItG g SINGLE AXIAL TESTItG H aCOPIES OF DOC TO DISTRIBUTION n - - - - - - - - - - - - - - - - - - - O

~

t a Sil0REHAll UNIT 1 GE LIST ST0tlE & HEBSTER EtiGIrlEE ItG CORPORATICH RUN D1TE 07/22/82

, JCB NUl!BER 11600 1-SORT GEt4ERAL ELECTRIC CATEGORY I EQUIPitENT RtAl TIHE 15.31.24 LILC3 00CHET 50-322 ACTIVE HSSS QUALIFICATI0tt LEVEL (139 ITEMS) PAGE 6 IIARM EQUIPl!EHT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL

.. tiutt0ER DE,5CRIPTION NO. VEtBOR ELEV INSP REPT tlETH FREQ HTts FUNC STATUS 1H11tPtL-631 AUTO DEPRESS H11P631 GE C8044 YES SAI-029QA80PA-B fBT 14 F CS G

, JH11tPIL-635 DIV 1 RAD IIONITOR H11P635 GE CB063 YES SAI-029QA80PA-B IET 21 F H G IH11tPit-636 DIV 2 RAD ll0NITOR H11P636 GE CB063 YES SAI-0290A80PA-B fBT 21 F H G

(. 1H11tPtL-654 HSIL LISPHCAGE H11P654 GE CB063 YES SAI-0290A80PA-B fBT 19 F H G (j 1H11tPtL-655 HISL LISHCAGE H11P655 GE C8063 YES SAI-029QA80PA-B tBT 21 F H G

( ,, 1H21tPtL-01 CORE SPRAY RM CH A H21P001 GE SC008 YES SAI-029QA80PA FET 11 F CS G ,

1H21tPfL-02 RHCU SYSTEH INST H21P002 GE SC151 YES SAI-029QA80PA IBT S F H G

(, , 1H21tPfL-04 RX VES L & P RACH H21P004 GE SC079 YES SAI-029QA80PA IBT 8 F HS.CS G IH21tPit-05 RX VES L & P RACH H21P005 GE SC079 YES SAI-029QA80PA fBT 8 F HS.CS G y 1H21tPit-06 RECIRC Pur A RAC H21P006 GE SC040 YES SAI-029QA80PA IST 11 H F G V IH21tPtL-09 JET PUtp A H21P009 GE SC079 YES SAI-029QA80PA HBT 11 F H G

( 1H21rPIL-10 JET PUIP IHST RH H21P010 GE SC079 YES SAI-029QA80PA HBT 11 F H G U 1H21tPtL-14 HPCI It4ST RACH H21P014 GE SC006 YES SAI-029QA80PA tBT 8 F H G

( 1H21tPtL-15 HAIH STH FLOH RH A H21P015 GE SC040 YES SAI-029QA80PA IST 8 F H G lil21tPit-16 CS/HPCI LH DET I H21P016 GE SC008 YES SAI-0290A80PA IST 11 F N G i 1H21tPtL-17 RCIC IllST RACH H21P017 GE SC008 YES SAI-029QA80PA IST S F HS G t 1H21tPIL-18 RHR INST RACH CH H21P018 GE SC008 YES SAI-029QA80PA IST 8 F HS.CS G 1H21tPtL-19 CORE SPRAY RM CH H21P019 GE SC008 YES SAI-029QA80PA IBT 11 F CS G t IH21tPtL-21 RHR INST RACH CH H21P021 GE SC008 YES SAI-029QA80PA IBT 8 F HS.CS G 1H21tPIL-22 RECIRC Pulp B RAC H21P022 GE SC040 YES SAI-029QA80PA IST S F H G v

_1H21tPtL-25 HAIN STH FLOH RH H21P025 GE SC040 YES SAI-029QA80PA IET 11 F H G

'~' CB =C0t4 TROL BLDG P = PIPE HOUNTED S8T= SINGLE FREQUEtiCY QUALIFICATI0H HILESTONES REVISION 3 -JULY 1982 CS = COLD SHUT 00lti PC =PRIttARY CONT. BIAXIAL TESTItG A = REEVALUATION COlPLETE DA :DYllAllIC AtlALYSIS PL = PEDESTAL SC =SEC0tBARY CONT. B = REQUEST FOR REQUAL OR BID ISSUED HOTE: NUtBER IN F = FLOOR HoutlTED QP = QUALIFIED BY / = LOCATED ON CONT. C =S/H REC 0ftlEfBATION TOLILCO HS = HOT STAtIDBY

' TYPE HTNG' COLuti IS PIPItG At4ALYSIS HALL D = QUAL DOC RECEIVED QUANTITY OF ITEttS.

HDT=ttULTI-FREQUENCY RH =RADHASTE T =HAIN STH. Tutt4EL E =HARDHARE HODIFICATICH REQ'D I BIAXIAL TESTItG SA = STATIC ANALYSIS H =HEITHER CS OR HS F = QUAL DOC APVD & FILED ttST=ltuLTI-FREQUEtiCY SAT =SIllGLE FREQUEtiCY G =SQRT PAPER C0tPLETE SINGLE AXIAL TESTItG SIttGLE AXIAL TESTItG H = COPIES OF DLC TO DISTRIBUTION O a m

)

SHOREHAH (MIT 1 GE LIST SToteE & HEISTER EtGIt4EE2Its CORPORATICH RLM DATE 07/22/82 e JOB NUlOER 11600 1-50RT GEHERAL ELECTRIC CATEGORY I EQU1PHENT RtM TIHE 15.31,2*4 LI'.C0 DOCHET 50-322 ACTIVE NSSS QUALIFICATION LEVEL (139 ITEllS) PAGE 7 IIAkN EQUIPitENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL i HUtBER DESCRIPTION HD. VEPOOR ELEV INSP REPT HETH FREQ HTfE FUNC STATUS IH21ePit-26 RV LV & PRES RN H21P026 GE SC079 YES SAI-0290A80PA IST 11 F HS.CS G g 1H21mPtL-30 SRit/IRH PREAFP RN H21P030 GE SC079 YES DRF A00-794-14 IST 4 F N G  ;

IH21tPtL-31 SRH/IRH PREAIP RN H21P031 GE SC079 YES DRF A00-794-16 tmT 4 F N G tj 1H21tPit-32 SRH/IRH PREAPP RN H21P032 GE SC079 YES DRF A00-794-16 IST 4 F M G (

1H21tPtL-33 SRH/IRH PREAfr RN H21P033 GE SC079 YES DRF A00-794-16 fBT 4 F N G

( 1H21tPit-34 HPCI LEAN DET RN H21P034 GE SC008 YES SAI-0294A80PA tBT 25 F M G t 1H21tPIL-35 CS/RCIC LN DET I H21P035 GE SC040 YES SAI-0290A80PA DET 11 F M G 1H21tPit-36

( HPCI LEAN DET RH H21P056 GE SC006 YES SAI-0290A80PA IST 11 F M G U l IH21tPIL-37 RCIC LEAN DET RN H21P037 GE SC008 YES SAI-0294A80PA IST 25 F M S '

( 1H21tPtL-38 RCIC LEAN DET RN H21P038 GE SC040 YES SAI-029QA80PA teT 11 F M G y.

1H21tPtL-41 FM STEAN FLOH IR H21PG41 GE SC040 YES SAI-0290A80PA fBT 11 F M G Q 1H21tPtL-73 HSIV LEANAGE RN H21P073 GE SC063 YES SAI-029QA80PA teT 11 M 1rt21sPtL-74 HSIV LEANAGE RN H21P074 F G Q

GE SC063 YES SAI-0290A80PA teT 8 F H G J

G1' 1

V' G!

l l

t l .. ) -

%.' O

-m l' CB = CONTROL BLDG P : PIPE HOLMTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 3 -JLA.Y 1982 l CS COLD SHUT DODN PC PRIHARY C0t4T. BIAXIAL TESTING A mREEVALUATION COIPLETE DA :DYt4AllIC ANALYSIS PL = PEDESTAL SC zSEcoteARY CONT. B zREQUEST FOR REQUAL OR BID ISSUED HOTES #AABER IN l

F = FLOOR HOUNTED QP squALIFIED BY / mLOCATED ON CONT. C zS/M RECotttEteATION TOLILCO ii

' ' TYPE HTNG' COLLAN IS g HS zHOT STANDBY PIPING AtlALYSIS HALL D zGUAL DOC RECEIVED QUANTITY OF ITEHS.

l t*3T=lfULTI-FREQUENCY RH sRAD64ASTE T zHAIN STH. TUTS 4EL E zHAR0 HARE NODIFICATION REQ'D

~~.

. RIAXIAL TESTItG SA STATIC ANALYSIS H zHEITHER CS OR HS F = QUAL DOC APVD & FILED HSTzHULTI-FREQUEtCY SATsSINGLE FREQUEICY G =SQRT PAPER COPPLETE ,

sit 4GLE AXIAL TESTING SINGLE AXIAL TESTING H sCOPIES OF DOC TO DISTRIBUTION i

I O ,n,, or . . . . . . . .

. . A _