a l!

/ 4;

(

b TEN YEAR' INSERVICE' INSPECTION-PROGRAM =

s Rev;?4

'A.<

.Sub$ect'.

Request for Relief' No. ISI-001: Pg.71 ofj 1 o

~B.

Component Classification Class 1 and 2 Code Examination: Category B-A, B-B, B-D, B-F, B-3,; C-A;; C-B, C-C,' C -F.

t.

C..

Examination Requirement-For each code " item' requiring a surface 1or volumetric examination l the:

examination tables'in;the Waterford 3 Ten Year Inservice Inspection Program-identify a figure which illustrates:the examination;requirementifor a specific code item. ~ These figures (wereiderived from those shown:in:

IWB-2500-1 through 20 and IWC-2500-1 through 13)ofisection:XILand have been:

enhanced to show exact weld configuration'asTitIexists-at' Waterford '3.

i j

i D.

Relief Requested J t Waterford 3 is requesting that relief be given in, reference to obtiaining

)

100% coverage when examining'certain items'scheduledLin Tables IWB-2500-1 t

(Cat. B-A, B-B, B-D, B-F, B-J) and IWC-2500-1 (Cat. C-A,;C-B,'C C, C-F).-

E.

Basis for Relief

.' l Class 1 and 2 piping-and components-are designed with welded joints such as flange-to-shell', pipe-to-elbow and pipe-to-component which physically; obstruct all or part of the required examination Everyc effort has been made when selecting welds to minimize'the number ofLwelds: requiring relief.

~

Alternate analyses, search units, vee. paths and other techniques will'be used to provide additional coverage where practical.' Waterford 3 has generated a detailed summary of the ASME-Code Class'1 and:2 piping and component welds which will receive a limited or partial examination. The a

sumary identifies the specific weld and the specific cause for the partial i

examination. This information is provided with as much detail as possible through a thorough review of the preservice' examination data and the' i

~

Partial Examination Summary which was included in the Preservice Inspection Report. The listing of welds recalving a partial exam is attached' (Attachment 1) to this relief request.

Waterford 3 has determined that the partial examinations to be performed, the examinations performed during f abrication, and the periodic hydrostatic test to be performed will demonstrate an acceptable level of integrity.

1 F.

Schedule for Implementation First 10 year Interval k

9009130025 900906 PDR ADOCK 05000302 G

PNU L

'm'

/

~ TEN: YEAR INSERVICE ~ INSPECTION PROGRAM-Rev.~ 4 Request for Rel'ief'No. ISI-001

' Attachment 1 Page 11of 14*

i

, Wold / Item Exam

= Code F D* s ignat '.on PT MT UT fategory-Item-

- Description Lof Limitation 01-006 X

B-A Bl.11 -

Core stop. lugs at-10", 40*, 85*,

160*,"205*, 2500, 280*, 325*

01-012

'X B-A Bl.11 Material' surveillance brackets at

~

830, 97*, 104*, 263*, 277*', 284*

01-027 K

B-D' B3.100

. Core barrel mating protrusions and nozzle? taper causes approx.-17%: loss of coverage'of the: accessible-exam' volume.with-core barrel ~in place.

Approx 27% loss'of coverage from-l total required volume due to core barrel in place, mating protrusions:

and nozzle taper.01-030 X-B-D.

B3.100 Core barrel mating protrusions and nozzle taper causes approx. 22% loss of~ coverage offthe accessible exam i

volume with core barrel-in place.

Approx. 32%Lloss'of. coverage from-total ~. required volume due to core-barrel in; place, mating protrusions and nozzle taper.02-001 X

B-A Bl.40; 6" wide lifting lugs' flush with weld toe located at 15*,-145*, 75*,

105*, 135*, 165*,1195*, 225, 255*,

285*, 315* and'345 02-001 X

B-A Bl.40 6" wide lifting. lugs flush witt weld toe located at-15*,.45*, 75,

105*,1135, 165*, 195*, 2250,- 255*,

285*, 3150 and 345, along withi shroud positioned 8" from weld toe 360* and flange located 5" from e

opposite: weld toe'360 'causes 20%~

loss of coverage-for 0* scan, 40% loss

cf coverage-for-300 scan, 40%

i loss of coverage for 45*~ scan, and 70% loss of coverage for 60* scan.02-002 X

B-A Bl.22 6" wide-lifting lugs located at_15' and 345*, aloLg with shroud which' covers approx.,50% of weld length, a

and weld 02-001 causes 70% loss of coverage for 0 -scan, 75% loss of-coverage for 45* scan, and 77% loss of coverage for 60* scan.02-003 X

B-A Bl.22 6" wide lif ting lugs located at 75*

and 105*, along with shrend which covers approx. 50% of-welt length, and weld:02-001 causes 70% loss ~of coverage for 0 scan, 75% loss ofl coverage for 45* scan, and 77% loss of coverage for 600 scan.

?

y gf j

TEN YEAR INSERVICE'INSPECTIONIPROGRAM-n' -

1RevF 4.

I s

~

t IRequest.for Rell'ef Ho'..ISI-001 Attachment'l Page 2.of.14' Weld / Item-RExam.

Code

. Designation PT 100

'UT

' Category ' Item Description of Limitation-02-004-X B-A Bl.22 6" wide lifting-lugs located at 165*:

{

and 195*. along with-shroud _which2 covers erprox. 50% of weld' length,"and.

, eld 02-003:causes 30%! total loss of-w coverage for 0, 30* and 45* scans 005 X

B-A-Bl.~ 22 6" wide lifting lugs. located at.255*-

and 285*,-along with shroud which

. covers: approx..50% of. weld lengthhand.

I weld 02-001 causea'30C totaliloss'of coverage forlD*,-30*'and 45* scans' 3

02-010 X

B-A.

Bl. 21-Shroud covering 100% of weld! length-causes complete' inaccessibility.03-002 X

B-B EB2.31 Steam Generator base support' configuration' limits'all-scans'asi 4

follows:0a(30%), 45o(70%), 60*(75%).

03-005-X:

LB-B B2.32 Nozzle configuration causes-10% loss-oficoverage for 45* ccan and(15%

loss of coverage for 600 s can '.'

l 03-007 X

B-B B2.32 Steam Generator-primary manway nozzle configuration and 1"-instrumentation line causes loss of. coverage ofil5%

for 45' scan and 20% for 60*-scan,03-008 X

B-B B2.31

.3/4"' instrument; nozzles at 21*,.

33*,'327' and 339* located'7)" from centerline of weld.03-032 X

B-B B2.31 Partial due~to: curvature of. stay.

cylinder causina loss of contact.04-002 X

B-B B2. 31 -

-Base support configuration (causes.-

j 30% loss of coverage for 0*' scan, 70% loss of coverage.for 45 scan and.75% loss'of-coverage'for 600-scan.04-008 X

B-B B',31 Tour (4) 3/4" ~ instrument nozzles approx. 7)" below centerline of weld located at 21*,'33, 327'_and g

339* along with two (2).24" primary..

manways located-at 0*'and 112, the 42" inlet nozzle' located at:180*,

and weld 04-009 which is' located 9" above centerline of. weld 04-008 360*.

These conditionsJ1Lmit exam to approx. 1% loss'of coverage for.0 scan, 20% loss of coverage for 45*

scan and 30% loss of coverage for 600 scan.

l

v I

e TEN YFAR INSERVICE INSPECTION PROGRAM Rev. 4 Request 'or Relief No. ISI-001 Page 3 of 14 Weld / Item ixum Code j

D signation pT MT UT CEtegory Item Deteription of Limitation 04-009 X

B-B B2.40 Weld configuration along with weld 04-008 which is located 9" below-centerline of weld 04-009 360* and

, eld 04-024 which is located 15" w

above centerline of weld 04-009 360* cause-2% loss of coverage for O' scan, 30% loss of coverage for 45' scan and 40% loss of' coverage for 60* scan.

)04-011 X

B-D.

B3.130 Nozzle configuration causes npprox.

30% loss of' coverage for 0* scan, 70% loss of coverage for 45' scan and 75% loss of coverage for 60* -

Scan.04-012 X

B-D B3.130 Nozzle configuration causes approx.-

=

30% loss of coverage for 0* scan, 70% loss of coverage ft 45* scan and.75% loss of ' coverage for 60*

scan.

1 04-024 X

C-A C1.30-Weld configuration and weld 04-025 which is located approx. 9".above.

centerline of weld 04-024 causes 2% loss of coverage for 0* scan,-

B% loss of coverage for.45' scan and 10% loss of coverage for 60*

-acan.

"~

04-025 X

C-A C1.1 Two (2) 6" handholes approx. 4"

-)

above' weld centerline located at 0* and 90*, and weld.04-024 which is located' approx. 9" below weld 1

centerline causes 2% loss of-coverage for 45' scan and 5% loss af coverace for 60* scan.04-026 X

C-A C1.10 Insulation support ring located 1

360* approx. 5" below centerline of weld 04-026, and weld config-uration causes approx. 2% loss of covetage for_Oo scan,'30% loss of-I coverage for 45' scan _and 55% loss of coverage for 60* scan.04-027 X

C-A C1.10 Two (2) 5" x 5" insulation pads.

on top side of weld obstructing j

scan j

04-028 X

C-A C1.20 Insulation support ring located approx. 11" below weld causos 4% loss of coverage for 45' scan and.10% loss of coverage for 60* scan 04-029 X

C-A C1.20 Instrument nozzles located 6" from 1

centerline of' weld at-40*, 80*

120*, 1600, 200*, 2400, 2806, 320*, 360*

]

l l:

i TEN YEAR INSERVICE TNSPECTION PROGRAM Rev. 4 Request for Relief No. ISI-001 Page 4 of 14 I

Weld / Item Exam Code D?signation PT MT UT Categ.ry Item Description of Limitation 04-030 X

C-B, C2.21 Instrument aozzles located 6" from centerline of weld at 45', 90' 135*, 180*, 225*, 270', 115*, 360' l

04-031 X

C-B C2.21

. Magnetic Particle probe limited to only one direction.for approximately 15" of the total 125" of weld length due to insulation support ring.,04-031 X

C-B.

C2.21 Due to nozzle configuration and t

insuletion support ring, 45' scans limited approx. 26% and 60'. scans limited approx. 24%.

't 04-032 X

B-B B2.31 Partial due to curvature of stay cylinder causing loss of contact.04-033 B-B B2.31 0' scan had I ss of contact on i

base metal above weld, 13)"-14" and 50"-15" Irom datum.

Obstructed by I.D. bevel.04-034 X

B-B B2.31 0' scan had loss of contact above-weld 1{"-2" and 50"-15" from datum. Obstructed by I.D. bevel.04-035 X

C-A C1.10 Approximately 5% loss of contact l

for O' scan due to 1.D. cap to tube sheet configuration.

1 05-002 X

B-B B2.11 Pressurizar skirt and weld config-uration causes B% loss of coverage

{

l for O' scan, 5% loss of coverage for 45' scan and 11%-loss of coverage for 60* scan.05-003 X

B-B B2.12 Weld 05-002 and weld configuration

[

along with insulation support ring t

(for downward 60* scan only) causes l

approx. 4% loss of coverage for O' l

scan, 3% loss of-coverage for 45*

scan and 7% loss of coverage for 60' scan.05-011 X

B-D B3.130 Nozzle configuration causes 60%

loss of coverage for O' scan and 75% loss of coverage for 45' anf 60' scans.05-012 X

B-D B3.110 Nozzle configuration causes 60%

loss of coverage O' scan and 75% loss of coverago for 45' and 60o senns.

?06-006 X

B-F B5.130 Approx. 10% loss of toverage for 45' scans due to nozzle configuration-

m 6

~'s TEN YEAR INSERVICE 2NSPECT10N PROGRAM Rev. 4 Request for Relief No. ISI-001 Page 5 of 14 Weld / Item Exam Code Designation PT MT UT Category Item Description of Limitation 07-001 X

B-J B9.11 Partial for all 45' scans due to 0.D. mismatch.

Scanning on the j

downstream side c'. weld-is

.res r c et i t d by a 1" nozzle.

The total loss of caverate is approx. 18%.07-002 X

B-F B5.130

. Partial for 45' axial scans due to 0.D. mismatch.

Circumferential scans are limited by about 15% for the coverage area.07-017 X

B-J B9.11 Partial for all 45' scans due to 0.D. geometry causing loss of contact. Loss of approx.

70% in the upstream direction, 50% in the downstream direction, and 10% in the circumferential directions.08-008 X

o-J B9.31 Approx. 22% loss of coverage on 45' axial scans due to nozzle radius on both sides of weld.08-014 X

B-F B5.130 Approx. 35% loss of coverage on all 45' scans due to 0.D. weld-configuration.of this weld and adiacent weld 08-015.08-015 X

B-J B9.11 Approx. 35% loss of coverage on f

all 45' scans due to 0.D. weld configuration of this weld and adiacent weld 08-014.09-001 X

B-J B9.11 Partial on all 45' scans due to 0 D. surface. geometry. The root area cannot be examiaea.

i 09-016 X

B-F B5.130 Approx._35% loss.of coverage for 45' scan due to weld configuration and weld 09-017.09-017 X

B-J B9.11 Approx. 35% loss of coverage for 45' scan due to weld configuration and weld 09-016.10-001 X

B-J B9.11 Approx. 35% loss of coverage for 43' scan due to weld configuration and weld 10-002.10-002 X

B-F B5.130 Approx. 35% loss of coverage for 45* scan due to weld configuration and weld 10-001.10-007 X

B-J B9.31 Approx. 30% loss of coverage for 45' scan due to 0.D.

radius of nozzle.

i 1

s TEN YEAR' INSERVICE INSPECTION PROGRAM' Rev. 4 R: quest for Relief No. ISI-001

Page 6 of 14 Celd/ Item Exam Code Designation PT MT UT Category Item Description of Limitation 10-012 X

B-J B9.11-All 45' scans are limited due to.

0.D.' mismatch. Losseof coverage is approx. 10% in tne upstrasm.

4 direction scan, 5% in the down-

'i stream direction scan, end:10%

for the circumferential direction scans.10-013 X

B-J B9.13 The upstream and circumferential

' direction 45' scans are restricted

by radius.of nozzle, O D. mismatch, and.a support lug.

The. upstream.

directica is totally obstructed by the support lug for a' length of 39" for a loss of 34%. The circumferential scans have a loss of 10%.11-001 X

B-J B9.11 All 45' scans are partial due to O.D. mismatch. The downstream side-or weld also has a 1" line attached to pump nozzle. Good f

root area coverage is obtained with the axial scans. The.cir-cumforential scans are limited by about 15% for the' coverage area.11-002 X

B-F B5.130 All 45* scans are partial due to 0.D. mismatch.

Good root area coverage is obtained with the axial scans. -The circumferential scans were limited by about 15%'

l' for the coverage area.

.11-017 X

B-J B9.11 Approx. 97% loss of' coverage-for 45' scan due to nozzle configura-tion and contour of weld 11-016 which restrict axial direction scane.12-001 X

B-J B9.11 The upstream axial and all circum-ferential 45' scant are limited I

approx. 30% due to support lug and nozzle configuration.12-002 X

B-J B9.11 The downstream (axial) scan (45*)

is limited by approx. 5% due to 0.D. weld configuration.

i

.t l

1

o

'i TEN YEAR INSERVICE IhSPECTION PROGRAM i

Rev. 4 R quest for Relief No. ISI-001

' Page 7 of 14 Weld / Item-Exam Code I

Designation

.PT MT ~ UT Category Item Description of Limitation 12-008 X

B-J B9.31 All 45' scans are partial due to nozzle l

j radius. Root area can be scanned in the upstream direction but rentact is~1ost before beam can i

pass completely through weld, i

Ccntact for circumferential scans j

can only be maintained on the downstream side of weld. Partial coverage of the heat affected zone and root area is obtained by directing the beam at a H

tangunt to the weld.- The down-stream direction 45' scan cannot j

be performed because the beam is directed eway from the weld and heat affected zone.12-009 X

B-F B5.130 Partial on all 45' scans due to sicpe of nozzle, O.D. mismatch and shrinkage on upstream side of weld.

Good root area coverageL is obtained.12-012 X

B-F-B5.130 All 45' scans are restricted by O.D. misr atch. Good root area l

coverage is obtained with the downstream direction scan. Mar-ginal. root area coverage is obtained with the upstream direction scan. The circum-

)

i ferential scans are limited by about 30% for the coverage area.

I 12-013 X

B-J B9.11 All 45' scans are restricted by

(

O.D. mismatch.- Good root area coverage is obtained with the l

upstream direction scan while only marginal root area coverage is obtained with the downstream t

direction scan. The circum-ferential scans are limited by about 20% for the coverage area.13-001 X

B-J B9.11 Approx. 97% loss of coverage for i

45' scan due to configuration of j

l nozzle and contour of weld 13-002 which restrict axial direction scans.13-035 X

B-F B5.130 All 45' scans are partial due to 0.D. mismatch. The circum-ferential scans are-limited by approx. 15%.

TEN YEAR INSERVICE INSPECTION PROGRAM {

Rev. 4 R: quest for Relief No. ISI-001 page 8 of 14

-i Weld / Item Exam Code I

Designation PT

~MT UT Category Item Description of Limitation 13-017 X

B-J B9.11 All 45* scans are partial due to 0.D. mismatch. Also,.the downstream scan was restricted by

.a 2" line. The circumferential scans are limited by about 15%.14-001 X

B-J B9.11-All 45*'L scans are_ limited by O.D. mismatch at the pump-to-safe end weld, and the safe end-to-pipe weld.. The circumferential scans are limited by about 20%

for the coverage area.14-002 X

B-F B5.130 All 45* L scans are limited by O.D. mismatch at the pipe-to-safe j

end weld, and the safe end-to-pump weld. The circumferential-I scans'are limited by about 30%

for the coverage area.17-030 X

B-J B9.11 Approx. 15% loss of coverage for 45* scan due to valve and weld I

contour. No scan can be performed in downstream direction due to valve.17-032 X

B-J B9.11 Tee-and weld crown restricts 45*

i circumferential scans on downstream side of weld frnm 21" to 39" from--

datum. This condition causes 5%

loss of coverage.18-022 X

B-J B9.11-No 45* scan can be performed in the

~

upstream direction due to valve body.

Valve also limits 45' circumferential-j scans.

Total loss of coverage is I

approx. 45%.18-027 X

B-J B9.11 No 45* scan can be performed in the upstream direction due to reducer taper.

Reducer also limits 45' circumferential scans.

i 18-029 X

B-J B9.11 Approx. 15% loss of-coverage on 45*

circumferential and downstream axial scans due to elbow intradose.18-059 X

C-F C5.21 partial 45* scans due to weld crown. Loss of approx. 5% coverage 360*.

)19-026 X

B-J B9.11

-Valve on downstream side of weld causes a partial for 45' circumferential l j

scans. No 45* scan can ba performed in the upstream direction.

f e

-w--

TEN YEAR INGERVICE-INSPECTION PROGRAM Rev.u4 Request for Relief No. ISI-001

' Page 9 of 14 Weld / Item Exam Code.

Designation PT MT UT Category Item Descriotion of Limitation'19-027 X

B-J B9.11 Valve on upstream side of weld causes a partial for 45' circumferential l

scans. No 45' scan can be performed in the downstream direction.19-055 X

C-F C5.21 Approximately 10% loss of con-tact for 45' circumferential' scans-due to l 0.D. weld geometry 360'.20-029 X

B-J B9.11 Approx. 5% loss of coverage for 45* scan in downstream direction due to 2" branch connection located approx. 4".from weld'eenterline.20-030 X

B-J B9.11 Approx. 16% loss of coverage for 45' circumferential scans due to 0.D. weld geometry.20-056 X

B-J B9.11 Valve on upstream side of weld and weld contour causes 45% loss of l

coverage 360* for 45' scans in the circumferential direction.

No 45* scan in the downstream direction cat - a performed.

.21-066 X

B-J B9.11 Approx. 20% lo's's of coverage for 45' scan due to valve configuration and weld crown. No scan can be performed in the upstream direction due to valve.

i 21-068 X

B-J B9.11 Approx. 20% loss of coverage for 45' scan due to valve configuration and weld crown.

No scan can be performed in the downstream direc-tion due to valve.22-053 X

B-J B9.11 Valve on downstream side of weld.

andweldcontourcausesapprox.10%lossofl coverage 360' for 45' circum-ferential scans.

No 450 scan can be performed in the upstream direction.

i 25-024 X

B-J B9.11 Weld crown causes approx. 10%

loss of contact 360 for 45' circumferential scans.25-026 X

B-J B9.11 Approx. 25% loss of contact for l

45' scan in the upstream direc -

l tien due to intrados of elbow on downstream side of weld for approx. 900 l

25-027 X

B-J B9.11 Approx. 25% loss of contact for 45* scan in the downstream direction due to intrados of elbow on upstream side of weld for approx.

10*.

~*

TEN YEAR INSERVICE INSPECTION FROGRAM Rev. 4-Request for Relief No. ISI-001

' Page 10 of 14 Weld / Item Exam Code Designation PT MT UT Category Item Description of 'gimitation 25-028 X

B-J B9.11 Approx. 10% loss of centact for 45' scan in the upstreas snd-cir-cumferential-directions due to weld

. crown and nozzle configuration 360'.25-029 X

B-F B5.40 Approx. 10% loss of contact fcr all 45' scans due to weld crown and nozzle configuration 360*.

~~~

26-006 X

.B-F B5.40.

Approx. 25% loss of coverage for 45* scan in the upstream direction l

due to nozzle configuration 360*.26-009 X

B-J B9.11 Approx. 10% loss of contact at toe of weld 360' for 45* scans.

l 45* axial scans also i

limited due to flange bevel on downstream side and weld 26-008 11" away on upstream side.26-010 X

B-F B5.40 Approx. 10% loss of coverage for.

45' scan due to nozzle configuration.41-001 X

C-F C5.21 Approx. 15% loss of coverage for 45' scans due to nozzle configuration.41-020 X

C"F C5.21 Approx. 20% loss of coverage for 45' scan'due to weld crown and' penetration.41-022 X

C-F C5.21 Approx. 35% loss of coverage due to nozzle and 0.D. weld configuration.42-001 X

C-F C5.21 Approx. 10% loss of coverage for all 45' scans due to weld transition 360'42-005 X

C-F C5.21 Approx. 25% loss of coverage for 45' scan in the upstream direction due to slope of reducer 360*.42-011 X

C-F C5.21 Approx. 10% loss of covrisge for 45' circumferential' scans due to weld crown 360*.

I L

42-024 X

C-F C5.21 Approx. 10% loss of coverage for all 45' scans due to weld transition 360*.43-001 X

C-F C5.21 Partial due to 2" pipe approx.

9" from toe of weld on down-t stream side of weld 180* from datum. This condition limits the 45' upstream and circumferential' scans.43-004 X

C-F C5.21 Partial for 45* scan in the upstream and circumferential directions due to schedule change j

in pipe. This is causing an approx.

15* sloped taper on the downstream j

side of weld.

~.

TEN YEAR INSERVICE INSPECTION FROGRAM Rev. 4 R: quest for Relief No. ISI-001 Page 11 of 14 Weld / Item Exam Code D*signation PT MT UT-Category Item Description of Limitation 43-049LA X

C-F C5.22 Approx. 16% loss of coverage for all-45' scans due to whip restraints i

blocking 1 ft. of weld length.43-079 X

C-F C5.21

. Approx. 40% loss of contact for 45*

scan in the downstream and-circumferential directions due to bevel on the upstream side of weld.43-082 X

C-F C5.21 Approx. 40% loss of coverage 360'

'or 45' circumferential scans-due l

valve on downstream side of weld.

No 45' scan can be performed in the-upstream direction.43-089 X

N/A N/A Approx. 40% less of coverage 360 for 45* circumferential scans l

due to valve on downstream side of weld.

No 45* scan can be performed in the downstream direction.

44-026LA X

C-F C5.22 Approx. 1% loss of coverage for 45*

scan at intersection of welds44-025 and 44-040.

44-041LA X

C-F C5.22 Approx. 1% loss of coverage for 45*

t scan at intersection of welds44-040 and 44-054.

44-086LA X

C-F C5.22 Approx. 1% loss of coverage for 45*

scan at intersection of welds44-085 and 44-087.

(44-089 X

C-F C5.21 Approx. 7% loss of coverage for 45 l

scan in downstream direction due to branch connection located 6" from weld centerline.

45 ;02 X

C-F C5.21 Approx. 10' loss of coverage for i

l 45* circumferential scans due to l

weld crown 360*.45-019 X

C-F C5.21 Approx. 8% loss of coverage for l

45* scan in downstream direction due to 3" branch connection on bottom of pipe.46-021 X

C-F C5.21 Nozzle configuration caused approx.

i

  • /5% loss of coverage 360' for 30*-

RL scans in the downstream and circumferential directions.

No 30' RL scan in the upstream direction l

can be performed.47-034 X

N/A N/A No 45' scan in the upstream direction l

and partial 45' circumf o ntial scans for a total loss of approx.

40% coverage due to valve.

e v

i TEN YEAR INSERVICE INSPECTION PROGRAM j

Rev. 4 Roquest for Relief No. ISI-001 Page 12-of 14 We'.d/ Item Exam Code Derignation PT MT UT Category Item Description of Limitation

]

51 003 X

C-F C5.21 Approx. 6% loss of coverage for 45 rean in downstream direction due to j

1" branch connection located 3" from weld.53-004 X

C-F co.42

. Partial for-45' circumferential scans due to tee cuil,'curation

-l on downstream side of wel4. No 45' scan can be performed it the upstream direction due to tr,a.51-009 X

C-F.

C5.21 Partial for 45' circumferential scans due to tee configuration on upstream side of weld. No 45' scan can be performed in the downstream direction due to tee.

51-018-900 X

C-F C5.21 Approx. 27% loss of coverage-for 45' scan due to weld crown which restricts all scans and valve body which restricts circumferential scans.

No scan can be performed in the upstream direction due to.

valve body.

51-WS-4 X

0-C C3.20 Partial exam due to bleedout caused by carbon steel shim cositioned flush with support 7

lug at two places approx. 7" in length.53-004 X

C-F C5.21 Partial for 45* circumferential scans due-to tee configuration on downstream side of weld.. No 45' ccan can be performed in-the upstream direction due to tee.

l 52-009 X

C-F C5.21 Partial for 45* circumferential scans l

i due to ter. :onfiguration on upstream side of weld.

No 45' scan can be performed in the downstream direction due to tee.

52-019-900 X

C-F C5.21 Approx. 27% loss of coverage for 45' scan due to weld crown which restricts all scans'and valve body which restricts circumferen-tial scans.

No upstream direction scan can be performed due to valve body.54-074 X

C-A C1.10 Partial for all 45' scans l

due to flange radius and weld contour.

~~

54-075 X

C-A C1.30 Partial for all 45' scans l

due to flange radius and weld contour.

-t

TEN YEAR INSERVICE INSPECTION PROGRAM Rev. 4 Request fot Relief No. ISI-001 Page 13 of 14 Weld / Item Exam-Code Designation PT MT UT Category Item Description of Limitation 55-040 3

C-F C5.21 1" drain line located 1" from weld and loss of contact at toe of weld-i causes approx. 15% loss of-coverage' for all 45' acans.

5'5-042 X

C-F C5.21 Approx. 12% loss of coverage for 45' scan in downstream direction due to 1" drain line located 1" from weld.55-051 X

C-F=

C5.21 No 45* scan can be performed in j

the upstream direction and approx.

10% loss of coverage for circum-'

ferential scans due to valve.55-068 X

C-F C5.21 Valve on upst:eam side of weld,-

reducer configuration 360', and I

loss of contact at toe of weld 360' causes partial for 45' scans in

'l' the upstream and circumferential i

directions. No 45* scan can be performed in the. downstream direction i

due to valve.55-070 X

C-F C5.21 Partial-for 45' scan in downstream l

direction due to 1" drain line at bottom of pipe on upstream side of:

l weld.'

45' scan in downstream direction is also limited by 0.D. weld taper'.55-075 X

(-F C5.21 Partial for. 45' scan in the uhstream l

~

direction due to 0.D. taper on downstream side of weld.55-078 X

C-F C5.21 Valve on downstream side of weld l

causes partial for,45' circumferential l

I scans. No 45' scan can be performed i

in the upstream direction due to valve.56-040 C-F C5.21 Approx. 85% loss of coverage for 45* scan due to-reducer which restricts the downstream and cir-

.cumferential direction scans, valve body which restricts upstream and circumferential direction scans and weld crown which restricts all= scans.56-042 X

C-F C5.21 Approx. 5% loss of coverage for 45' scan due to weld crown which restricts circumferential ;;.

and 1" branch connection at bottua of pipe which restricts downstream direction scan.

_56-047 X

C-F C5.21 Approx. 20% loss of coverage for l

45* scan dus to penetration and weld crown. 'No upstream direction scan can be performed due to pene-tration.

TEN YEAR INSERVICE INSPECTION PROGP.AM R;v. 4

{

R: quest for Relief No. ISI-001 Page 14 of 14

.)

Weld / Item-Exam Code Designation PT MT UT Category Item Description of Limitation

{

56-050 X

C-F C5.21 Valve on downstream side of weld causes partial for 45* circumferential l

directions.

No'45' scan can be performed

)

in the upstream direction,due to valve.

]

56-070 X

C-F C5.21 1" drain line located 1" from weld

{

causes approx. 15% loss of coverage j

for 45' scan in the upstqum_ direction.56-072

-X C-F C5.21 1" drain line located 1.5" from weld i

causes approx. 11% loss of coverage for 45* scan in the downstream direction.56-080 X

C-F C5.21 Valve on downstream side of weld and weld crown causes partial for-45' scans in the downstream and j

circumferential directions.

No 45' scan can be performed in the upstream direction due to valve.

J 61-0b1 X

C-F C5.11 Approx. 30% loss of contact for 45' circumferential scans due to tee configuration on upstream side of weld. No 45* scan can be performed in the downstream direction due to tee.61-071 X

C-F C5.11 Approx. 40% loss of coverage for 45' scans due to ell-to-flange weld configuration 360'.61-073 X

C-F C5.11 Approx. 1% loss of coverage for 45' circumferential scans due to weld crown.

61-0B0 X

C-F C5.11 Approx. 1% loss of coverage for 45* circumferential scans due to weld crcwn.62-047 X

C-F C5.11-No 45' scan can be performed in the-(

downstream direction due to tsi,62-075 X

C-F C5.11 Tee on upstream side of M 3 causes partial for 45' circumb watial scans.

l No 45' scan can be pcu orned in downstream direction due to tee.62-07B X

C-F C5.11 Valve on downstrew, side of weld and f2 weld crown cause ; approx. 30% loss l

of coverage for 45' circumferential X

scans. No 45' scan can be performed in the upstream direction due to valve.62-089 X

C-F C5.11 Flange on downstream side of weld causes partial for 45' circumferential l

scans. No 45' scan can be performed in the upstream direction due to flance.

l M

.l

,p' 4

  1. ~

.L

TEN YEAR INSERVICE INSPECTION PROGRAM Rev. 4 P

A.

Subject Request for Relief No. -ISI-003 Pg.1 of 1 B.

Component Classification Class 1.

Code. Examination Category B-L-2 and B-M-2 (Items B12.20 and B12.50) l~

i C.

Examination Requirement i

A VT-3 internal' examination shall be performed on.one pump or valve within each I

design group each Inspection Interval.

t D.

Relief Requested Relief is requested to defer the required internal examination until maintenance / disassembly is required.

j

,r E.

Basis for Relief The Code requirement to disassemble'one pump or valve from each design group ' l' for the purpose of visual examinations has:a small potential for identification of service induced flaws or degradation.

Industry performance of.these components has proven their excellent ability to' resist service degradation or-l flawing. The inappropriate balance of potential flaw detection and the large l

l impact on expenditures of manpower without substantially increasing component reliability is considered impractical. Also, the substantial-expenditures of l

man-rem without increasing component integrity is undesirable due to ALARA i

concerns. As an alternative, these examinations will be performed when disassembly is required for maintenance purposes, but not more than once per i

Inspection Interval. Waterford 3 has determined that delay of these examinations until maintenance is performed will not affect the function or integrity of these components.

F.

Schedule for Implementation l

First 10 year Interval-l 4

9 I

3 e

s e

t g.

TEN YEAR INSERVICE INSPECTION PROGRAM Rev. 4 4

4

.)

~

t:

4 g4'

'si v

t'f 3

Roquest for Relief No. ISI-004

.m DELETED

~

?

4 b

h t.Y s '

,I' s

a I

g

.?

[

4 -

4 1:

a hIfs a

_.yc

-..{,

q'fg

  • ? 5

,k L

6

$v.*

A 5

. TEN YEAR IHSERVICE INSPECTION PROGRAM-Rev; 4<

c s

i Request for Relief No. ISI-005 DELETED

TEN l' EAR INSERVICE INSPECTION PROGRAM-Rev. 4

A.

Subject Request for Relief No. ISI-006.pg. 1 of 1 B.

Component Classificajion Class 3 Component Supports C.

-Examination Requirement Table IWF-2500-1, Category F-C, Items F3.10 through F3.40'- Mechanical connections to pressure boundaries and building structures, weld connections to building structures, weld and mechanical connections at intermediate joints and support assembly and alignment shall be 100% visual (VT-3) examined.

D.

Relief Requested Total relief from the visual examination describcd above is requested for the supports listed in Attachment 1.

partial relief from the visual examination is requested for the supports listed in Attachment 2 where the supports connect to the pressure boundary (i.e., the portion of the support which is beneath insulation).

E.

Alternate Exams Using the Waterford 3 support selection process in the Chilled Water (AC) system, approximately 60% (81) of the component suppot.

would be selected for examination under normal circumstances. However, Waterford 3 has opted to examine 100% (134) of the component supports in the AC system,from the insulation surface to the building structure. The supports;Nhich are completely blocked by insulation or would normally require insulation removal for examination are listed in Attachment 1 or 2 as appropriate, i

F.

Basis for Relief 1

Component support access is completely or partially blocked by permanent j

non-removable insulation.

Supported lines operate at temperatures substantially below ambient and are, therefore, subject to severe condensation.

The type of insulation used has a permanently sealed vapor barrier to exclude moisture, and removal of the insulation in the support area results in vapor contamination of the surrounding insulation.

possible alternate removable type vapor barrier insulation is not acceptable due to fluoride / chloride content.

The requirement for a vapor barrier necessitates non-removable insulation.

During the construction phase, examinations were conducted to verify acceptability of the entire component support installation in accordante with the toplicable construction codes. Examination records are on file by support numbet.

1 l

G.

Schedule for Implementatier.

First 10 year Interval

l TEN' YEAR INSERVICE INSPECTION PROGRAM.

Rev. 4 l

Request for Relief No. ISI-006 Pg. 1 of 1 Componen't(s) - Supports listed below

.j 1.

l l

System (s) k, led Water (AC) l Relief - Inaccessibility - Restraint access coupletely blocked.by permanent' thermal I

insulation.

Support No.

Line No.

Code Class ACR-408 3AC6-41A,42A 3-l ACR-410, 3AC6-41A,42A 3

-ALV-419 3AC6-41A,42A 3

ACR-513 3 AC8-7 A,14 A.

3 ACR-515 3AC8-7A,14A 3:

I ACR-522 3AC6-53A 3

ACR-523 3AC6-52A' 3

ACR-551 3AC6-40A-3-

q ACR-561 3AC6-2BB, 29B 3-ACR-563 3AC6-2BB, 29B 3

ACR-570 3AC6-43B

,3 ACR-1034 3AC10-15A 3-ACR-1036 3AC6-42A

=3 i

ACR-1058 3AC6-40A

-3 ACR-1087 3AC6-40B

3 ACR-1131 3AC6-43B 3

I I

i

[

l

-I i

+

4 TEN YEAR INSERVICE INSPECTION PROGRAM Rev. 4 Request for Relief No. ISI-006

-- Attachment 2 Pg. 1 of 2~

Component (s) - Supports listed below System (s) - Chilled Water (AC)

Relief - Partial Inaccessibility - Restraint access partially blocked by permanent thermal. insulation.

Support No.

Line No.

Code Class ACR-406 3ACG-41A,42A 3

ACR-407 3AC6-41A,42A 3

ACR-409 3AC6-41A,42A 3

ACR-417 3AC6-41A,42A 3

-ACR-421 3AC6-41A,42A 3

ACR-422 3AC6-42A 3

ACR-423 3AC6-41B,42B 3

ACR-424 3AC6-41B,42B 3

ACR-425 3AC6-41B, 42B' 3

ACR-426

.3AC6-41B, 42B 3

ACR-427 3hc6-41B,.42B 3

ACR-428 3AC6-42B 3

ACR-429 3ACG-42B 3

ACR-430 3AC6-42A 3

ACR-431 3AC6-41B 3

ACR-433 3AC6-41B,42B 3

ACR-435

'3AC6-41A,42A 3

ACR-441 3AC6-22B 3

ACR-442 3AC6-1A, 7B, 14B 3

ACR-443-3AC6-22A 3

ACR-444 3AC10-6A, 6B, 15A, 15B 3

3AC6-2A, 2A/B, 14B, 19A, i

19A/B, 27B, 92B ACR-445 3AC6-1B

'3 ACV-446 3AC6-1B 3

ACR-448 3AC6-22A/B 3

ACR-449 3AC6-22A/B 3

ACR-450 3AC6-21A/B 3

ACV-451 3AC6-22A/B 3

ACR-452 3AC6-19A/B, 22A/B 3

ACR-453 3AC6-1A/B 3

ACR-454 3AC8-14A 3

ACR-455 3AC8-7A 3

ACR-457 3AC6-2A/B, 19A/B 3

ACR-458 3AC6-22A 3

ACR-459 3AC6-1A, 1A/B, 2B, 19A, 3

1 19B, 19A/B ACR-462 3AC6-2A, 2B, 19A, 19B ACR-468 3AC6-1B,:0B 3

ACR-470 3ACG-21A 3

ACR-471 3AC6-20B 3

ACV-472 3AC6-22A 3

ACV-473 3AC6-22B 3

ACR-474 3AC6-22B 3

ACR-476 3AC6-7B, 14B 3

w-

4 y

. TEN YEAR' INSERVICE INSPECTION PROGRAM' Rev. 4 Request Ice Relief,No. 131-006 Attachment'2 Pg. 2 of 2 Support No.

Line No.

Code Class ACd-478 3AC6-22B 3

ACR-479 3AC6-22B 3

ACR-4BO.

3AC6-22A 3

ACR-497 3AC6-7B, 14B 3

ACR-499-3AC6-7B, 14B' 3

ACR-512 3ACB-7A, 14A 3-ACP-514 3ACB-7 A, 14 A 3

ACR-516 3ACB-28A, 29A 3

ACR-517 3AC8-2BA, 29A 3

ACR-520 3AC6-52A 3

ACR-521-3AC6-53A-ACR-524 3AC6-52A, 53A 3

ACR-525 3AC6-52A,153A 3'

ACR-526 3AC6-52A, 53A 3

I ACR-535 3AC6-7B, 14B 3

ACR-536 3AC6-7B, 14B 3

ACR-540 3AC6-28B, 29B 3

ACR-543 3AC6-28B, 29B 3

ACR-544 3AC6-2BB, 29B 3

ACR-550 3AC6-40A, 53A 3

ACR-552 3AC6-52A, 53A 3

ACR-559 3AC6-43A, 209A 3~

ACR-560 3AC6-2BB, 29B 3

ACR-562 3AC6-2BB, 29B 3

ACR-564 13AC6-2BB, 29B 3

ACR-565 3AC6-28B, 29B

~3 ACR-566

3AC6-2BB,'29B 3

ACR-568 3AC6-40B 3

ACR-569 3AC6-40B, 43B, 49B=

3 ACR-574 3AC6-209B.

3 ACR-575 3AC6-209B, 210B 3

ACR-576 3AC6-210B 3

ACR-58B 3AC6-209A, 210A-3 ACR-589 3AC6-209A, 210A 3

ACR-595 3AC6-209B 3

ACR-596 3AC6-209B 3

ACR-597 3AC6-209B 3'

ACR-604 3AC6-210B 3

ACR 605 3AC6-210B 3.

ACR-607 3AC6-209A, 210A 3

h ACR-612 3AC6-43A, 209A 3

ACR-1019 3AC6-42B 3

ACR-1027 3AC6-41B 3

L ACR-1037 3AC6-42A 3

l ACR-1059 3AC10-6A 3

ACR-1060 3AC6-42B 3

ACR-1064 3AC10-6B 3

ACR-1088 3AC6-53A 3

ACR-1093 3AC6-29B 3

ACR-1094 3AC6-2BB 3

ACR-1100 3AC6-22A/B 3

1 l

l

m TEN YEAR INSERVICE INSPECTION PROGRAM Rev. 4 A.

Subtect Request for Relief No. ISI-007 p. i of 1 g

B.

Component classification Class 2 and 3 Component Supports,

C.

Examination Requirement Table IWF-2500-1, Category F-C, Items F3.10 through F3.40 - Mechanical connections to pressure boundaries and building structures, weld connections to building structures, wel.d and mechanical connections at intermediate joints and support assembly and alignment shall be 100%

visually (VT-3) examined.

D.

Relief Requested Total relief from the visual examination described above is requested for the supports listed in Attachment 1.

E.

Alternate Examinstions An additional support, similar in type, design and function will be 100%

visually examined for each support listed in' Attachment-1, with the exception of the supports identified with an asterisk. The asterisk identifies the supports which are located on systems in which 100% of the supports of similar type, design and functicn have been. selected for examination.

F.

Basis for Relief component supports are in penetrations which~are closed off by permanently installed fire seals.

Fire seal material'is p.. ped into the penetration I

in semi-11guld state and solidifies into a non-removable mass.. Fire seal integrity is a Limiting condition for operation as identified in Waterford 3 Technical Specification paragraph 3.7.11.

This constitutes undue hardship in conducting exams.

During the construction phase, examinations were conducted to verify acceptability of the component support installations in accordance with.

l the applicable construction code (s).

Examination records are on file by support number.

l G.

Schedule for Implementation i

First 10 year Interval j

i

e

'4 ~

10 YEAR INSERVICE INSPECTION PROGRAM Rev '4 Request for Relief No.-ISI-007 Pg. 1 of I Component (s) - Supports listed below System (s) - Chilled Water (AC). Component Cooling (CC), Containment Spray (CS),

Safety Injection (SI).

Relief - Inaccessibility - Restraint in penetration with permanent fire' seal.

Support No.

Line No.

Code Class.

ACR-412*

3AC6-42A 3

ACR-413*

3AC6-41A 3'

ACR-586*

3AC6-41A 3

ACR-587*

3AC6-42A 3-ACR-600*

3AC6-41B 3

ACR-601*

3AC6-42B 3

CCRR-37*

3CC6-144A/B 3

CCRR-420 3CC16-202B 3

CCRR-445 3CC20-201B CCRR-465*

3CC6-71A 3

CCRR-471*

3CC6-71A

'3 CCRR-712 3CC20-3B 3

['

CCRR-715 3CC20-2B 3

CCRR-764 3CC20-2B 3

CCRR-948 3CC20-2B 3-CCRR-1091 3CC6-106B 3

CCRR-1122 3CC10-290B 3

CSRR-361 2CS10-7B 2

CSRR-372 2CS10-9B 2

SIRR-391 2SI8-113RLIA 2.

i All supports within this system which are similar in type, design and function have been selected for examination. Therefore, another similar support cannot be examined as an alternative to this support.

I i

i

ik' o j '.,.

TEN YEAR INSERVICE INSPECTION PROGRAM R3v. 4 1

i l

l

' i i

t i

4 l

-\\

.j 1

J Request for Relief No. ISI-008

?

DELETED

?

f f

'6 et t

T 1

1 h

P f

,ic.',*,-.

TEN-YEAR INSERVICE INSPECTION PROGRAM

' Rey, 4 6

t 5

~ i 1.aquest for. Relief No. ISI-009 DELETED i

-t

, 1 l

l 1.

- i 5

g

e s

TEN YEAR INSERVICE INSPECTION PROGRAM Rev.'4 j

i A.

Subject Request for Relief No. ISI-010 pg. l'of'1 i

B.

Component Classif2 cation Class 3 Component Supports l-C.

Examination Requirement

-Table IWF-2500-1, Category F-C, Items F3.10.through F3.40 - Mechanical-connections to pressure boundaries and building structures, weld connections to building structures, weld and mechanical connections at intermediate joints, l

and support assembly'and alignment shall be 100% visually (VT-3) examined.

D.

Relief Requested partial relief from' the visual examination described above is. requested for. the supports listed in. Attachment I where the supports connect to the building structure.

I E.

Alternate Exams The accessible portions of'the affected supports are examinedi to the frequency I

and extent specified in INF-2500-1 and IWF-2510..All supports within this-system which are sin.ilar in type, design and function have been selected for l

examination.

Therefore, other similar supports cannot be examined as alternatives to these supports.

(

1 l

F.

Basis for Relief l

l Component support access is partially blocked by fire / heat' resistant insulation applied to protect supporting structural steel. The insulation is applied by spraying Flamastic or pyrocrete over a wire mesh support..The insulation solidifies into a non-removable mass approximately 3"-5" thick.. Fire barrier integrity is a Limiting Condition for Operation as identified'in.Waterford 3 Technical Specification paragraph 3.7.11.

This constitutes undue hardship in conducting exams.

During the construction phase, examinations were conducted to vecf fy-acceptability l

of the entire component support inst allation in accordance with~ the applicable construction codes.

Examination records are on file by support numbe..

k l

G.

Schedule for Implementation First 10 year Interval.

. g* *.

TEN YEAR INSEINICE INSPECTION PROGRAM Rev. : 4 Request for Relief No. ISI-010 Pg. 1 of 1 Component (s) - Supports listed below System (c) - Component Cooling (CC).

Relief - Partial Inaccessibility - Restraint access partially. blocked by permanent fire / heat insulation.

Support No.

7,ine No.

Code Class CCRR-467 3CC6-71A 3

I CCRR-468 3CC6-71A 3

CCRR-469 3CC6-71A 3

CCRR-470 3CC6-71A 3

i CCRR-529-3CC6-71B '

3 CCRR-530 3CC6-71B-3 CCRR-531 3CCC-71B 3

CCRR-1068 3CC6-71A 3

b t

. ;' ?.

o

' TEN YEAR INSERVICE INSPECTION PROGRAM Rev.~'4 5

A.

Sub$ect Request-for Relief No. ISI-011 Pg. 1 of 1 B.

Component Classification d

Class 2

'?

Code Examination Category C-B.(Item C2.22) l t

C.

Examination Requirement A volumetric examination-shall be performed on;the insiac re' t re ' on.of'all nozzles at terminal ends offpiping runs.. In the case of nn.

1 p. T < g er a of similar design; size ~and service, the required e nminatic a. < ce u

d to f r

one vessel or distributed among the vessels.. The examini-W-s4 o

performed.to the extent and frequency as specified in IWC.

. c1

~t C-B)..

D.

Relief Requested Relief from the volumetric examination described above is requested for the Main Steam and Feedwater nozzles.

E.

Alternate Examinations A complete VT-1 examination and a surface examination of at least 10% of the required area will be performed on the inside radius section of the Main Steam-and Feedwater nozzles in lieu of the volumetric examination reqvired by IWC-2500-1 (C-B).

F.

{ysis for Relief The leometric configuration of the Steam Generator Main Steam abd Feedwater nozz'es does not lend itself to a meaningful volumetric examination in the area of tLe inner radius. Only a small percentage of the area. required'by code-to be v)1umetrically examined would actually be examined even when employing several different beam angles. Therefore, Waterford 3 proposes to perform the alternate examinations described above on the nozzles 104-063 & 04-064) when

]

the secondary side of the Steam Generator is opened for other inspection / maintenance activities. The nozzles which would normally have received a volumetric examination will be subjected to the alternate examinations not more than once per Interval. The alternate examinations which l

are proposed represents the most reasonable and meaningful examination when considering the extrene lLmitations on the volumetric examination required by Code.

G.

Schedule for Implementation First Ten year Interval.

~.,

a f g' *,

~

TEN YEAR INSERVICE INSFECTION PROGRAM Rev.L4 A.

Subject Request for Relief No. ISI-012 Pg. I of 2 j

i B.

Component Classification Class 2 Code Examinatirn Category C-d (Items C7.30 and C7.70)

'+

C.

Examination Requirement A VT-2 examination conducted-during a System Functional or Inservics test

[IWA-5211(b) and (c)) is required on systems or portions of systers which are required to operate or support the safety system function.-

D.

Relief Requested Total relief from the visual examination described above is requested'for the i

lines listed in Attachment 1 and their associated valves.

E.

Basis for Relief has been categorized into three (3) groups of piping. Each group is in an area of the plant that has been determined to be inaccessible during operation. Although a System Functional or Inservice test will not be-performed on the linea (or portions of lines) listed in Attachment 1, these.

lines will be hydrostatically tested to the extent / frequency required by Section XI.

i GROUP 1 This group represents piping which has been determined to be inaccessible due l

to being located in crawl spaces (22' x 15' x 4'9") under each of the three'(3)

Charging pump rooms. High contamination and radiation levels of 100-500 mr/hr 1.

(1000 mr/hr on contact) during operation of the Charging pumps are the reasons that this piping is completely encased in the concrete enclosure.

GROUP 2 This group represents piping which has been determined to be inaccessible due.

to being located in a radioactive pipe chase. This piping runs from the Charging pumps to the h? generative HX and is encased in lead brick shielding.

To access the piping, the shielding must be removed.

Radiation levels-vary between 120-150 mr/hr with the shielding removed.

c gn *,

a TEN YEAR INSERVICE INSPECTION PROGRAM Rev. 4-Request for Relief No. ISI-012

-r Pg. 2'of 2

.E.

Basis for Relief (con't)

GROUP 3 This group represents piping which is located;in an inaccessible radioactive pipu chase. Piping from several systems is contained within the pipe chase.

This piping includes thelline which runs from the Charging pumps to.ths, Regenerative HX.(sameLllne in.Grcup 2), therefore, radiation levels lduring.

operation of the Charging pump are high.(120 150 mr/hr). This area'is completely enclosed behind's concrete block wall.

F.

Schedule for Implementation First 10 year Inturval-i c

t

[M.

j

.a;

!'fi[f f }

yr TEN YEAR INSERVICE INSPECTION PROGRAM LRev. 4-l Request' for 'Re' lief No. - ISI-012

Attachment '1 : Pg. 'I of 2 ~

L.

3 t

' Component (s) ' Lines listed below i

ESystom(s) - Component Cooling (CC), Cl.arging (CH),?Feedwater (FW)

Relief ;-' Located in ' areas which are inaccessible during operation.

  1. 1) Piping Loceted Under Charging Pump Room Floor-Line No.

Size-

. Flow Diagramc Footage-2CH1-30' 1"

G-168 sh.2

1' o

2CH1-33 1"-

G-168 sh.'1 11 ' -

G-168 sh52-.

83

2CH4+40A/B E4i 2CH4-41A~

(4" :

LG-168 sh.2' 14

f 2CH4-41A/B-4"'

G-168-sh.2-

' 4 '..

2CH4-41B 4"

tG-168 sh.2-4't 2CH2-44A/B 2":

-G-168 sh 2; 17' F

y 2CH2-51A-2" G-168 sh.2

.4

2CH2-51A/B 2"

G-168 sh.2

-4

2CH2-51B 2"

G-168 sh.2

' 4 ';

j 2CU2-52A/B

'2" G-168.sh.2 "17' i

2CH2-53A/B' 2"

G-168 sh.3&2

? 71 ' '

s 2CH1-1/2-137A/B 1-1/2" G-168 sh.2 1 *=

2CH3/4-152

?/4" '

G-168 sh.-2

1'

.i I

a

  1. 2) Piping Located in Radioactive Pipe Chase

~

Line No.

Size Flow Diagrarr Footage 2CH1-33 1"

G-16C sh.1 l'

2CH2-53A/D 2"

G-168 sh.1&2 124' 2CH2-1/2-54A/B 2-1/2" G-1GS sh.1 6'

2CH1/2-233 1/2" G-168 sh.1' n

Y e

{

  1. 3) Piping Located in Inaccessible Radioactive Pipe Chase Line No.

Size Flow Diagram Footage' 3CC20-2A 2 0

G-160 sh.2 45' 3CC20-2B 20" G-160 sh.2 32' l

3CC20-3A 20" G-160 sb.2 32' 3CC20-3B 20" G-160 sh.2 40' 3CC20-4A 20"'

G-160 sh.1&2 28' 3CC20-4B 20" G-160 sh.1&2 34' 3CC10-8A 10 *'

G-100 sh.1 16' 3CC10-8B 10" G-160 sh.1-4 '.

3CC10-10A 10" G-l',0 sh.1&3 30' 3CC10-10B 10" G-160 sh.1&3 11'

.3CC18-11A/B 18" G-160 sh.1&2 34' 3CCG-71A o"

G-160 sh.1 62' 3CC6 71B 6"

G-160 s.

1 34'

. i l

_m

-~

y' o - h 4

-o.

ef TEN YEAR INSEAVICE' INSPECTION PROGRAM y

- Rav. 4[

V 9

Request for Relief No.lISI-012 g 'Pq. 2;of;2-

  1. 3) ~(con't).

Line N6.

Size-Flow Diagram-Footage-3CC10-83A 10" G-160.sh.1&3 19' 3CC10-83B l10" G-1,60 sh.1&3

\\

3' 3CC10-89A 10" G-160 sh.1 3'

4 3CC10-89B 10"

.G-160 sh.1

'3

3CC6-106A' "

6"

~ G-160:sh.2&3=

32' 3CC6-106B~.

. 20"

-G-1601sh.1&2

40'

'6"

-G-160 sh.203

=42'~

3CC20-107A.

. 3CC20-107B' 20" G-160 sh.1%2' B3' 3CC8-119A/B 8"-

G-160:sh.1 13' 3CC8-139P/3 8"

G-160'sh.1 56' 3CC4-145A

-4" G-160'shi3E3 19'-

3CC4-145B 4".

G-160 sh.1&3.

21' 3CC16-156A/B-

18"

'G-16b sh.1&2 27'

- 3CC16-202A 16" '

G-160 sh.2 53' 3CC16-202B 16" G-160 sh.2 27

'3CC16 ~.33A 16" G-160 sh.2' 30' H

3CC16-203P

~16" G-160^sh.2' 25'-

3CC10-289A 10" G-160 sh.2 38' i

3CC10-290B 10" G-160 sh.2 40' j

2CH2-53A/B 2"

G-168-sh.1&2 BO '. -

l 3EG2-4A 2"

~ G-164.sh'.1

-58'-

I 3EG2-5B 2"

G-164 ah.1 60':

3FW6-19A

-6" G-153 sh.4' 64'-

3FW6-22B 6"

'G-153 sh.4

92'

~i 3FW4-46 4"

G-153 sh.4 22' 3FW4-47 4"

G-153 sh.4.

12' 3MSB-91A/B 8"

G-151.

B?.

,i j

3

[

)

l 1

i i

//

%Fs p er#W.7

~