S/G Eddy Current 12 Month Special Report Page 1 of 20 i

i ATTACMENT A SPECIAL REPORT SR-os-001-00 j

STEAM GENERATOR EDDY CURRENT EXAMINATION (6TH REFUELING) j INTRODUCTION 4

j Inservice eddy current examination of Waterford 3 Steam Generator (S/G) tubing was l

l completed by Conam Nuclear, Inc., a B&W Nuclear Service Company, on March 28, 1994.

l This report is submitted in accordance with Technical Specification 4.4.4.5, which i

4 requires the complete results of this inspection be submitted in a special report pursuant to Technical Specification 6.9.2, within 12 months following the inspection.

l The eddy current testing included 100% full length bobbin coil examinations of each steam generator. Additionally, Waterford 3 performed Motorized Rotating Pancake Coil (MRPC) examinations on the hot legs of both steam generators. This examination was focused in the sludge pile region which is subject to OD initiated stress corrosion cracking and intergranular attack. The number of tubes included in this augmented scope totaled 6,102 tubes for S/G #1 and 6,110 tubes for S/G #2. The tubesheet MRPC l

examination scanned two inches above and below the tubesheet interface. As a result of the top of the tubesheet MRPC examination Waterford 3 identified No Detectable Degradation.

i In response to industry concerns for upper bundle hot leg sludge deposition and potential freespan axial indications, Waterford 3 performed MRPC on 303 tubes in S/G i

  1. 1 and 305 tubes in S/G #2. The upper bundle MRPC examination criteria was the longest freespan of tubing adjacent to the partial eggcrate scallop bars. ~ This

'l included MRPC scans from the eighth, ninth and tenth partial eggerates through the anti-vibration bar (Batwing BW1) to the first vertical support intersection. The MRPC examination results identified No Detectable Degradation.

S/G tube examinations were conducted in accordance with USNRC Regulatory Guide 1.83 and ASME Section XI using Conam Nuclear, Inc. procedtre 42-EC-227, "Multifrequency Eddy Current Procedure Steam Generator Tubing MIZ-18/. or MIZ-30 Digital Eddy Current System Waterford 3."

As a result of eddy current te!, ting, S/G #1 had two defective tubes which were plugged in accordance with B&W Nuclear Service Company's " Field Procedure for Rolled Plugging," Drawing, 1154835. The steam generator tube plugs were manufactured from thermally treated Inconel-690. Additionally, all tube plug locations were positively identified and video taped verifying correct tube locations.

9503230060 950321 PDR ADOCK 050003B2 Q

PDR

S/G Eddy Current 12 Month Special Report Page 2 of 20

)

As a result of verifying S/G #1 tube plug locations, it was noted that a Westinghouse Inconel-690 mechanical plug was leaking from the OD of the plug at hot leg location Row 121 Line 45. The tube plug location Row 121 Line 45 was previously plugged with a Inconel-600 Westinghouse mechanical plug during RF #2 for a 41% through wall cold leg indication. Subsequently, Spring 1991 (Refuel 4) the Inconel-600 hot leg plugs were j

replaced with Inconel-690 (3 in each S/G) due to their susceptibility to Primary i

Water Stress Corrosion Cracking. Upon investigation as to the failure of the

]

Westinghouse Inconel-690 mechanical plug, it was determined that the machining of the previous Inconel-600 mechanical plug resulted in the plug tops remaining in the l

tubesheet of S/G #1.

In order to install the Inconel-690 mechanical plug at location Row 121 Line 45, l

Westinghouse had to push the plug remnants up into the tubesheet. During this j

process of pushing the plug remnants, the tube ID was probably scored resulting in an inadequate seal between the tube ID and plug lands. The review of Westinghouse QC l

Process Data Sheets for the other S/G #1 hot leg tube plugs did not involve pushing l

the plug remnants prior to accepting the Inconel-690 plugs. As for S/G #2, the plug remnants were removed prior to the installation of the Inconel-690 mechanical plugs.

Another factor which may have led to the plug failure was that tube location Row 121 Line 45 is out on the peripheral of the bundle approximately thirteen inches from the curvature of the bowl. The confines of the tight curvature and the outer bundle tube location made it difficult to push the plug remnants into the tubesheet. Vaterford 3 contracted B&W Nuclear Technologies to machine S/G #1 hot leg tube plug location Row 121 Line 45 and install a tapered welded plug manufactured from Inconel-690. The above stated information was documented in Condition Report CR-94-308.

RESULTS OF EXAMINATION STEAM GENERATOR #1 The eddy current testing of 9,018 tubes in S/G #1 resulted in the following analysis of indications:

101 Tubes Less Than 20% Thru Wall 39 Tubes Greater Than or Equal to 20% But less Than 40% Thru Wall 2 Tubes Equal to 40% Thru Wall (Plugged) 1 Low Row Tube Obstructed Between 7H and 70 Row 2 Line 10 (Plugged)

S/G Eddy Current 12 Month Special Report Page 3 of 20 i

The following tube listing identifies the indications as a result of examining 9,018 l

tubes (100%) in S/G #1:

l i

RAM LINE

%THRU WALL LOCATION COMMENTS i

I I

l 41 5

<20%

6H 67 11 27%

BW3 INDICATION @ -0.54" 55 13

<20%

BW6 f

74 14

<20%

BW1

<20%

BW4 61 15 24%

BW6 INDICATION @ -0.65"

<20%

BW6 64 16

<20%

BW5 62 18

<20%

BW4 84 18

<20%

BW3 42 20

<20%

BW5 81 21

<20%

8C 72 24

<20%

BW5 28 26 20%

BW1 INDICATION @ 40.00" 67 27

<20%

BW5 71 27

<20%

BW4 77 27

<20%

BW6 66 28

<20%

3C 101 33 29%

4H INDICATION @ +28.49" 68 34 26%

4C INDICATION @ +0.18"

S/G Eddy Curr:nt 12 Month Special Report Page 4 of 20 l

89H LINE

%THRU WALL LOCATION COMMENTS 80 38

<20%

BW6 82 38

<20%

BW5 23%

BW6 INDICATION 9 -0.74" 113 39

<20%

BW7 42 40

<20%

BW5 50 40

<20%

BW5 54 40 28%

5H INDICATION 9 +5.53" 39 41

<20%

BW5 45 41

<20%

BW5 87 41 23%

BW9 INDICATION 9 +2.52" 32 42

<20%

4C 30%

4C INDICATION 0 +14.59" 59 45 24%

IC INDICATION @ +9.97" 44 46

<20%

BW5

<20%

BW5 45 49

<20%

BW5 59 49

<20%

BW5 46 52

<20%

BW5 50 52

<20%

8H 43 53

<20%

BW5 49 53 38%

BW5 INDICATION @ +0.69" 33%

BW5 INDICATION @ +0.74"

S/G Eddy Current 12 Month Special Report Page 5 of 20 RQW L1HE

%THRU WALL LOCATION COMMENTS 105 53

<20%

BW3 82 54

<20%

BW5

<20%

BW5 131' 55 26%

9H INDICATION @ -0.29" 27%

9H INDICATION 0-0.23" i

50 56

<20%

BW5

<20%

BWS 126 56

<20%

BW2 85 59

<20%

BW4 129 59

<20%

BW3 30 60

<20%

BW5 138 69

<20%

8H 49 61

<20%

8H 135 61 40%

BW5 PLUGGED WITH B&W I-690 HT #CE79-2 26 62

<20%

BW9 20%

7C INDICATION 0 +12.65" 84 62

<20%

BW3 46 64

<20%

BW5 43 65

<20%

BW5 44 66

<20%

BW5 50 66

<20%

BW5 27 67 23%

3H INDICATION @ +27.58"

S/G Eddy Current 12 Month Special Report Page 6 of 20 l

?

RQM LINE

%THRU WALL LOCATION COMENTS l

51 67

<20%

BW4 l

135 67

<20%

BW3 l

79 69 26%

5H INDICATION 9 +24.98" 145 73 25%

BW1 INDICATION 9 +0.75" l-146

-76 32%

BW1 INDICATION 9 +1.60" l

29%

BW1 INDICATION 9 +1.62" 51 77

<20%

BW4 e

113 77

<20%

BW1 l

133 77

<20%

BW3

<20%

BW4 68 78 22%

BW6 INDICATION 9 +0.78" 146 78

<20%

BW4 51 79

<20%

BW9

<20%

BW9 78 80

<20%

BW5 146 80 35%

BW1 INDICATION 9 -1.89" l

33%

BW1 INDICATION 9 -1.68" 147 81

<20%

BW1 l

40%

BW1 INDICATION 9 +1.83 PLUGGED WITH B&W I-690 HT# CE79-2

<20%

BW9 82 82

<20%

BW5 141 85

<20%

BW3 1

i S/G Eddy Current 12 Month Special Report l

Page 7 of 20 RQM LINE

%THRU' WALL LOCATION COMMENTS 60 86 20%

BW9 INDICATION 0 +1.55" 62 86

<20%

BW9 i

80 86

<20%

BW9 64 88

<20%

BW9 146 88 24%

BW1 INDICATION 0 +1.67"

<20%

BW9 147 89 20%

BW1 INDICATION @ -1.51" l

120 90

<20%

10H 146 90 38%

BW1 INDICATION 0 +1.76" 34%

BW1 INDICATION 0 +1.77" 147 91

<20%

BW9 54 92

<20%

8H 107 93

<20%

BW6 145 93

<20%

BW9 147 93 21%

BW8 INDICATION 0 -0.78"

<20%

BW9 l

145 95 21%

BW9 INDICATION 0 -1.57" 82 96

<20%

BW5 83 97

<20%

BW5

<20%

BW6 70 98

<20%

BW4 78 98

<20%

BW6

S/G Eddy Current 12 Month Special Report Page 8 of 20 89)(

Lite

%THRU WALL LOCATION COMMENIS 49 99

<20%

BW1 145 99

<20%

BW9 78 100 22%

BW6 INDICATION 9t+0.69" 146 100

<20%

BW1 145 101

<20%

BW1

<20%

BW9 48 102 25%

BW5 INDICATION @ -0.75" j

66 102

<20%

BW4 72 102

<20%

BW4 74 102

<20%

BW4 144 102

<20%

BW9 55 103 23%

BW1 INDICATION @ +1.03"

<20%

BW5 123 103

<20%

BW2 145 103 20%

BW1 INDICATION @ +1.61"

<20%

BW2

<20%

BW7 22%

BW8 INDICATION 0 +0.74"

<20%

BW9 24%

BW9 INDICATION @ +1.55" 82 104 22%

8C INDICATION @ +27.69" 8B 106

<20%

BW3 144 106

<20%

BW1 1

143 107

<20%

BW1 4

S/G Eddy Current 12 Month Special Report Page 9 of 20 l

l BE LIE

%THRU WALL LOCATION COMENTS I

24 108

<20%

BW5 I'91 CATION 9 -0.70"-

d 42 108 25%

BW5 I

22 112

<20%

BW5 l

29 113

<20%

BW5 l

141 113 20%

BW9 INDICATION 9 -1.33" 19 115 25%

IH INDICATION @ +5.71" l

49 115

<20%

BW5 48 118

<20%

TSH 135 119 26%

BW2 INDICATION 0 -0.57"

<20%

BW2 20%

BW3 INDICATION @ +0.71" 27%

BW4 INDICATION @ -0.79" 23%

BW4 INDICATION 9 +0.88" 72 120

<20%

BW4 45 121

<20%

TSH 133 121

<20%

BW2 22%

BW2 INDICATION 0 +0.78"

<20%

BW3 74 124

<20%

BW5 72 126

<20%

BW4 64 128

<20%

BW4 i

}

S/G Eddy Current 12 Month Special Report Page 10 of 20 RQM LINE

%THRU WALL LOCATION COMMENTS 76 128

<20%

BW4

<20%

BW5

<20%

BW5

<20%

BW6

<20%

BW6 105 131

<20%

BW3 103 133

<20%

BW3 114 136

<20%

IC 63 137

<20%

BW5 70 138

<20%

BW4

<20%

BW4 25%-

BW5 INDICATION @ -0.77" 21%

BW6 INDICATION @ -0.80" 23%

BW6 INDICATION @ +0.71" 82 138 22%

BW6 INDICATION @ +0.93" 18 140 35%

6H INDICATION @ +27.23" 76 140

<20%

BW6 82 140

<20%

BW4

<20%

BW6 85 141

<20%

BW3 78 142

<20%

BW5

<20%

BW6 44 144

<20%

BW5 48

.44

<20%

BW5 74 144

<20%

BW5

<20%

BW6

i 4

S/G Eddy Current 1.2 Month Special Report Page 11 of 20 BQM UE

%THRU WALL LOCATION COMMENTS 78 144

<20%

BW4

<20%

BW4

<20%

BW5

<20%

BW6 84 144

<20%

9H 81 147

<20%

BW6 83 149

<20%

BW7 i

28 150

<20%

3C 58 152 21%

BW5 INDICATION 9 -0.46"

<20%

BW5 86 152

<20%

JW3 44 156

<20%

BW5 i

STEAM GENERATOR #2 I

The eddy current testing of 9,005 tubes in S/G #2 resulter' in the following analysis of indications:

84 Tubes Less ihan 20% Thru Wall e

59 Tubes Greater Than or Equal to 20% But less Than 40% Thru e

Wall No Tubes Equal to or Greater Than 40% Thru Wall e

2 Tubes Stabilized and Plugged Due to Possible Loose Part on e

Hot leg Secondary Side Row 138 Line 114 & Row 137 Line 115 The following tube listing identifies the indications as a result of examining 9,005 tubes (100%) in S/G #2:

1 1

S/G Eddy Curr:nt 1.2 Month Special Report j

Page 12 of 20 BQW LIE

%THRU WALL LOCATION COMMENTS 19 3

<20%

BW5 41 15 28%

TSC INDICATION 0 +9.09" 44

-16 29%

BW5 INDICATION 0 -0.46"

<20%

BW5 48 18 25%

BW5 INDICATION 9 -0.79" 48 20 33%

BW5 INDICATION 9 +0.73" j

36%

BW5 INDICATION 0 +0.73" l

90 20

<20%

9H 5

21

<20%

TSC 76 24

<20%

BW4

<20%

BW5 91 25 32%

6C INDICATION @ +19.43" 30 26

<20%

BW1 I

l 80 28

<20%

BW6 103 29

<20%

7C 94 30 23%

9C INDICATION @ -0.06" 46 32

<20%

BW5 i

81 33

<20%

BW9 36 34 31%

3H INDICATION @ +9.04" 83 35

<20%

BW5

<20%

BW7 1

43 37

<20%

BW5

<20%

BW5

i' l

S/G Eddy Current l

12 Month Special Report l

Page 13 of 20 l

ROM LIE

%THRU WALL LOCATION COMMENTS 77 37

<20%

BW4

<20%

BW5 1

20%

BW5 INDICATION @ +0.64" l

44 40

<20%

BW5 l

94 40

<20%

BW6 i

80 44 26%

BW4 INDICATION @ -0.85" l

l 39 45 24%

IC INDICATION @ +24.31" 44 48

<20%

BW5 j

l l

74 48 24%

BW4 INDICATION @ +0.88" 23%

BW5 INDICATION @ +0.88" 80 48

<20%

BW5 l

77 49

<20%

BN5 81 49 22%

BW5 INDICATION @ +0.86"

<20%

BW6 1

66 50 26%

BW9 INDICATION @ +1.54" 49 51 33%

BW5 INDICATION @ +0.57" 37%

BW5 INDICATION @ +0.79" 134 52

<20%

BW1 107 55 24%

BW5 INDICATION @ +0.00"

<20%

BW5

<20%

BW6 82 56 29%

BW5 INDICATION @ -0.73" 94 56

<20%

BW4 l

49 57

<20%

6H

t S/G Eddy Current 12 Month Special Report Page 14 of 20

)

j i

1 l

89M _

LIE

%THRU WALL LOCATION COMMENTS l

)

73 57 22%

BW6 INDICATION @ +0.85" 77 57

<20%

BW5 81 57

<20%

BW4 48 58 21%

BW5 INDICATION 9 -0.78" 45 59 20%

3C INDICATION 0 -0.55" 70 60

<20%

BW9 L

98 60

<20%

BW6 i

77 61

<20%

BW4

<20%

BW4 1

133 61

<20%

BW3 21%

BW5 INDICATION 9 +0.68" 137 61

<20%

9C 46 64 27%

BW5 INDICATION 0 +0.78"

<20%

BW9 89 65 32%

BW5 INDICATION 9 -0.88" 32%

BW5 INDICATION 0 -0.73"

]

120 66

<20%

10H 46 68

<20%

BW5

<20%

BW5 i

43 69

<20%

BW5 28%

BW5 INDICATION 0 +0.75" 77 71

<20%

BW4

<20%

BW5

<20%

BW5 l

l

4 S/G Eddy Current 12 Month Special Report Page 15 of 20 R9)(

LIE

%THRU WALL LOCATION COMMENTS 92 72

<20%

BW5 120 72

<20%

10H 50 74

<20%

8H 141 75

<20%

BW1 121 77

<20%

BW5 145 77

<20%

BW8

)

102 78

<20%

BW3 l

i 146 78

<20%

BW9 i

146 80

<20%

BW9 i

146 82 31%

BW1 INDICATION @ +1.25" i

30%

BW1 INDICATION @ +1.95" l

145 83 24%

BW1 INDICATION @ +1.64" 54 84 29%

BW1 INDICATION @ -1.66" i

146 84 20%

BW9 INDICATION @ -1.68" 97 85

<20%

BW4 145 85

<20%

BW8

<20%

BW8 i

33%

BW9 INDICATION @ -1.75" 36%

BW9 INDICATION @ +1.78" 147 85

<20%

BW6

<20%

BW7 56 86

<20%

BW9 i

144 86 27%

BW1 INDICATION @ +1.47" i

4 J

S/G Eddy Current-12 Month Special Report Page 16 of 20 i

R0W LJE

%THAU WALL LOCATION COMMENTS 81 87

<20%

BW6 145 87

<20%

BW9-147 87 27%

BW2 INDICATION @ -0.68" j

<20%

BW7

)

<20%

BW7

<20%

BW8 26%

BW8 INDICATION 9 +0.03" 136 88 25%

SH INDICATIC's @ +0.66" I

146 88

<20%

BW1 32%

BW1 INDICATION 9 +1.79"

<20%

BW9 l

145 89

<20%

BW8

<20%

BW8 144 90

<20%

BW9 146 90

<20%

BW9 147 91 23%

BW8 INDICATION @ -0.75" 29%

BW8 INDICATION 0 -0.06" i

<20%

BW8 l

145 93 23%

BW9 INDICATION 0 +1.56" l

145 95 23%

BW8 INDICATION @ -0.70" l

<20%

BW9 66 96

<20%

BW1 106 96 37%

7C INDICATION 0 +28.52" 30%

7C INDICATION 0 +28.40" i

146 96

<20%

BW9 i

l l

l l

l l

S/G Eddy Current 12 Month Special. Report Page 17 of 20 BDW LLE

%THRU WALL LOCATION COMMENTS

)

l 81 97 25%-

BW5 INDICATION 0 +0.76"

<20%

BW6 103 97

<20%

BW4

<20%

BW7 1

50 100

<20%

8H l

144 100

<20%

BW9 49 101

<20%

8H 145 101

<20%

BW3 69 103 35%

BW4 INDICATION 0 -0.77" 33%

BW4 INDICATION 0 -0.71" 26%

BW6 INDICATION 0 -0.53" l

l l

143 103

<20%

BW9 l

145 103

<20%

BW9 i

l 112 104

<20%

BW9 114 106

<20%

BW4 144 106 24%

BW1 INDICATION 0 +1.50" 113 109

<20%

BW3 137 111

<20%

BW8 56 112 20%

4H INDICATION 0 +1.64" 31%

4H INDICATION 0 +1.73" 135 113

<20%

BW8 30 114 22%

3C INDICATION 0 +25.99" 138 114

<20%

TSH l

S/G Eddy Current l

l.

12 Month Special Report Page 18 of 20 t

RQM L1HE

'4THRU WALL LOCATION COMMENTS 77 117

<20%

BW6 85 117 26%

1H INDICATION 9 +28.37" 133 117

<20%

BW3

<20%

BW3 74 118 21%

BW4 INDICATION 9 -1.18"

<20%

BW5 l

84 120

<20%

TSC 83 121

<20%

BW4 r

33%

BW5 INDICATION 9 -0.29" 39%

BW5 INDICATION 0 -0.23" 23%

BW6 INDICATION @ -1.10" 30 122

<20%

TSH

)

I 50 122 20%

8H INDICATION @ -1.22" 41 127

<20%

BW5 131 127

<20%

BW1 82 128 22%

BW5 INDICATION 9 +0.89"

<20%

BW6 49 131 28%

BW5 INDICATION 0 -0.80" 28%

BW5 INDICATION @ -0.07" 125 133

<20%

BW4 100 134

<20%

BW1 124 134

<20%

7C 21%

6C INDICATION 0 -0.09" 41 139

<20%

BW5 l

S/G Eddy Current 12 Month Special Report Page 19 of 20 l

RRM L1HE

%THRU WALL LOCATION f0MMENTS 16 140

<20%

BW1 37 141

<20%

BW5 l

l 109 141 20%

BW5 INDICATION 0 +0.75" 45 143 36%

BW5 INDICATION 9 +0.61" 38%

BW5 INDICATION 9 +0.69" 105 143 23%

BW3 INDICATION 0 +0.63" 45 145 29%

BW5 INDICATION 9 -0.66" 52 146

<20%

4C i

47 147

<20%

BW5 21%

BW5 INDICATION 0 +0.75" l

91 147 22%

9C INDICATION @ -0.94" 41 149 23%

BW5 INDICATION 0 +0.98" 43 149

<20%

BW5 49 149 24%

BW5 INDICATION 0 +0.82" 101 149

<20%

BW3

<20%

9C 4

l

<20%

9C l

57 151

<20%

7C i

l

\\

37 155 22%

BW5 INDICATION @ -0.92" 49 155 37%

BW5 INDICATION @ +0.68" 34%

BW5 INDICATION @ +0.76" 37 157

<20%

BW5 8

158

<20%

IC

S/G Eddy Current 12 Month Special Report Page 20 of 20 R91 LIE

%THRU WALL LOCATION COMMENTS i

38 158

<20%

BW5 70 160

<20%

8C 55 163

<20%

TSH 41 167

<20%-

BW5 45 167

<20%

BW5 26 170

<20%

BW1 1

175' 21%

1H INDICATION 0 +0.03" 11 175

<20%

BW1 PLANT CONTACT J.E. Howard Manager Procurement / Programs (504) 739-6327