ML20058F130
Text
i
,d'hiEECy\\
NUCLEAR REGULATORY COMMISSION V
.. E RCGION I!!
'k
[
799 Ro0SEVELT ROAD I
p oLEN ELLYN,ILLINo15 60137 co..+
AUG 4 1981 MDiORANDUM FOR:
J. F. Streeter, Acting Director, Enforcement and Investi-gation Staff R. F. Warnick, Reactor Projects Section 2B A. B. Davis, Deputy Direct :
J.E. Foster,Investigatorh FROM:
SUBJECT:
CONTENT OF ZDNER INVESTIGATION REPORT From an editorial standpoint, the Zimer Investigation report is progres-sing well, and a good draft effort should be available by Friday, August 7, 1981.
However, now that most portions of the report have been edited, and I am getting a feel for the co=pleted report, I have some concerns (from cn investigative standpoint) regarding the content of the report. Listed by apparent importance, these concerns are as follow:
1.
There is no statement by Kaiser QA Manager Gittings.
2.
There is no statement by Schwiers, Marshal, or Swain (there are no statements by Kaiser or CG&E management).
3.
There is no information on the study done by Gladstone Labs. This study was (at least partially) the reason that Kaiser personnel felt that their inspectors were over-inspecting and writing unjustified NRs.
4.
We need to include a statement on whether we will re-contact Hof-stadter, Martin, Griffin, Reynolds, and others and what the basis of the contact will be if they are re-contacted.
5.
Almost all personnel in the report are fully named, whereas most investigation reports include a more extensive use of individual identifiers.
6.
We never obtained the notes from Mark flertsgaard of his contacts with site workmen.
7.
More information is required on the original noncompliance issued by Isa Yin for improperly voiding nonconformance reports (NRs).
8207300305 820609 PDR FOIA DEVINE82-206 PDR M
I ;_. ;, y ^
4 l
Multiple Addressees I 8.
There is_no indication that was interviewed in person, and thei statement appears inconsistent with some of the allegation ascribed to him.
W James E. Foster Investigator h
6 I
_