Notice of Violation from Insp on 930615-0726.Violation Noted:Maint Workers Identified Need for & Installed Electrical Jumper W/O Performing Work Request Scope Change
ML20056H226
Person / Time
Site: Seabrook 
Issue date: 08/31/1993
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20056H224 List:
References
50-443-93-13, NUDOCS 9309090022
Download: ML20056H226 (3)


Text

. - - - _ - - _ - _ _. _ _ _ _

NOTICE OF VIOLATION North Atlantic Energy Service Corporation Docket No. 50-443 Seabrook Station, Unit 1 License No. NPF-86 During an NRC inspection conducted from June 15 to July 26,1993, a violation of NRC requirements was identified. In accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C, the violation is listed below:

Seabrook Station Technical Specification Section 6.7.1 requires that procedures shall be implemented covering activities recommended in Appendix A of Regulatory Guide 1.33, Revision 2, February 1978. Appendix A in Regulatory Guide 1.33, 1

Step 1.d specifies that an administrative procedure for procedural adherence be i

established and implemented. The Seabrook Station Management Manual Section 5.2 specifies that all personnel performing work shall comply with written instructions.

The following are two examples where procedures were not implemented as required or delineated in the respective procedure sections listed below:

a.

Maintenance Procedure MA 3.1, Step 4.1.2 specifies that when the scope of the work request changes after the work has been released, the person making the change shall receive concurrence from the system engineer, the quality control inspector, and the unit shift supervisor. The changes shall be documented on the work request.

Contrary to the above, when performing maintenance on containment isolation valve SB-V9 on June 17, 1993, maintenance workers identified the need for and installed an electrical jumper without performing a work request scope change. Consequently, on June 18,1993, the valve inadvertently closed during restoration from the work.

b.

Maintenance Procedure LS0564.19, Step 8.14.2.4 specifies to increase the torque on the pipe plug until the limit switch lever on main steam isolation l

valve (MSIV) 88 is tight.

Contrary to the above, on October 22,1992, maintenance workers signed that Step 8.14.2 had been completed when the pipe plug had not been tightened.

(

Consequently, on May 20,1993, MSIV-88 failed its routine operability surveillance test.

l i

This is a Severity Level IV violation (Supplement I).

9309090022 930031 PDR ADDCK 05000443 O

pyg

Notice of Violation 2

Pursuant to the provisions of 10 CFR 2.201, North Atlantic Service Corporation is hereby required to submit a written statement or explanation to the U.S. Nuclear Regulatory Commission, A'ITN: Document Control Desk, Washington, D.C. 20555 with a copy to the Regional Administrator, Region I, and a copy to the NRC Resident Inspector at the facility that is the subject of this Notice, within 30 days of the date of the letter transmitting this Notice of Violation. This reply should be clearly marked as a " Reply to a Notice of Violation," and should include for each violation: (1) the reason for the violation, or, if contested, the basis for disputing the violation, (2) the corrective steps that have been taken i

and the results achieved, (3) the corrective steps that will be taken to avoid further violations, and (4) the date when full compliance will be achieved. If an adequate reply is not received within the time specified in this Notice, an order or a Demand for Information may be issued to show cause why the license should not be modified, suspended, or revoked, or why such other action as may be proper should not be taken. Where good cause is shown, consideration will be given to extending the response time.

l k

i i

i i

I

'b l

1 1

SEABROOK SERVICE LIST Thomas Dignan, Esquire Diane Curran. Esquire John A. Ritscher, Esquire 11armon and Weiss t

Ropes and Grav 2001 S Street, N.W.

One Internatio6al Place Suite 430

]

Boston, Massachusetts 02110-2624 Washington, D.C.

20009 Mr. J. F. Opeka Regional Administrator, Region 1 i

Northeast Utilities U.S. Nuclear Regulatory Commission P. O. Box 270 475 Allendale Road lianford, Connecticut 061414270 King of Prussia, Pennsylvania 19406 t

Mr. A. David Rodham, Director John P. Arnold, Attorney General Massachusetts Emerrency Management Agency G. Dana Bisbee, Associate Attomey 400 Worchester Roa3, Box 1496 General Massachusetts 01701 0134 Attomey General's Office Framingham, James B. Muckerheide 25 Capitol Street ATTN: Mr.

State Nuclear Engineer Concord, New liampshire 03301 j

Robert Backus, E Mr. R. M. Kacich Backus, Meyer anYuire Solomon Nonheast Utilities Service Company 116 lowell"$treet P. O. Box 270 Manchester New 11ampshire 03106 Hanford, Connecticut 06141-0270 Mr. T. L.11arpster Office of the Attomey General North Atlantic Enercy Service Corporation One Ashburton Place 2

Post Office Box 300 20th Floor Seabrook, New Hampshire 03874 Boston, Massachusetts 02108 Seacoast Anti-Pollution League Town of Exeter 5 Market Strcet 10 Front Street Ponsmouth, New llampshire 03801 Exeter, New llampshire 03823 j

Mr. David W. Graham Stephen G. Burns Director Fuel Supply Planning Manscer Office of Commission Appellate i

Massachusetts Mumcipal Wholesale U.S.judication

~

Ad Electric Company Washington, D.d~.ulatory Commission Nuclear Re 20555 P. O. Box 426 Ludlow, Massachusetts 01056 i

Gerald Garfield, Esquire Board of Selectmen Da, Berry and floward Town of Amesbury Ci Place Town 11all i

11 ford, Connecticut 06103-3499 Amesbury, Massachusetts 01913 j

Resident inspector Mr. Peter Brann l

U.S. Nuclear Regulatory Commission Assistant Attorney General l

Seabrook Nuclear Power Station State llouse, Statmn #6 i

Post Office Box 1149 Augusta, Maine 04333 Seabrook, New 11ampshire 03874 Jane Spector Adjudicatory File (2)

Federai Energy Regulatory Commission Atomic Safety and Licensing Board Panel l

S25 North Capital Street,"N.E.

Docket Roorn 8105 U.S. Nuclear Regulatory Commission Washington, D.C.

20426 Washington, D.C.

20555 Mr. George L Iserson, Director Mr. Jack Dolan New llampshire Office of Emergency Federal Emcrgency Management Agency l

Manatement J.W.gion 1McCormack Post Office and Re State Office Park South 107 Pleasant Street Courthouse Building, Room 442 Concord, New llampshire 03301 Boston, Massachusetts 02109 j

Atomic Safety and Licensing Board Panel t

U.S. Nuclear Rerulatory Commission Washmpton, D.C.

20555 i

i 6

h i

n

-.. - - - - - -. - - -. -