(7 77) b LICENSEE EVENT REPORT CONTROL BLOCK: l i

l l l 1 l lh e

(PLE ASE PRINT OR TYPE ALL REOUiRFD INFORMATIONI lo Iil8 lM 7 9

! NLICENSEE l P lICODE lN l2 @l0 14 16 0 - l0 l0 l0 0lOl-l010l@l4l1l1 LICENSE NUMBER 26 /ti 1l1l@l Ll0ENbt TvFE JJ l

61 CAT W 1@

CON'T 0 141719 l@l016l0 l1 1 7l 91@

ULL1J 7 6 E IL @l01510 0101 310 16 GIO is EVEN1 60 61 DOCS ET NUMeg n 68 69 DATE 74 7b At PORT DATE tio EVENT OE$CRIPTION AND PROB ABLE CONSEQUENCES h 10lil During power operation, nuclear power rante channel 2N43 faC C4 low due tojoss of I

[o Iai high voltage. Protection channel inputs were placed in trip within minutes. Not j repetitive. No effect on public health and safety, j o 4 l O b l

[O c l 0 7 l l

0 b l o SYSTEM CAUSE CAUSE C oMP. VAtyt CODE CODE SueCODE COVPONENT CODE SUBCODE SUFCODE Loloj

8 lT IA h ([_)h lG lh lIlNlSlT 9 10 11 11 13 R U lh lP lh t tt 19 N Zl h SEQUENTI AL OCCUR Ri N C E REPOAT HE VM A ttp no EVENT YE AR REPORT NO CODE TvPE NO h afront l7l9l l-j 0Jll5l l/ l0 l3 L l-l l0 l 24 i6 27 28 M Je Ji J2

_ 21 22 /J SHUTOOWN A TT AC HV E NT NP AD 4 PAIVE COMP CO*'PO*.f N T ACTION SUTUAE EFFECT M ANLI ACTUHIH TAKEN ACTION ON PL ANT YETHOD HOUR 5 < SUB VIT T E D FORM bVB $UPPLI E H JJ C l@lJ4 Z l@ l Zj@

JS l2@

30 3 010l0l0 40 lNl@

41 lY @ lNl@

41 43 44 Wl1l2l0l@ 4' CAUSE DESCRIPTION AND CORRECTIVE ACTIONS i o Failure of a Power Designs, Inc., high voltage regulated DC source Model No. UPMD - l l

X; A. Power supply was replaced. l I

i ,

I I

i 3 l i 4 I

I i Y 9 St S 6POWEA OTHENSTATUS 5 v DISCOV E 44 DE sCH+P TION yE @ l1l0l0l@ NA l lAl@l Operator Observation I AC fi vi t y CO T E B. T HELE ASED Of AELE ASE AYOUNT OF ACflVITY L OC AIlON OF HE L E ASE NA NA 1

i c lZ @ l Zl@

H 9 10 11 41 40 i

PE R?,0*aNE L F x PO9UHE S NUP38 E H TYPE DE SLTM P TION '

i 7 l 0 l 0 l 0J@l Z l@l NA J PEnsONNE tNJUN r.;

P.UVR E 4 OESCRIPflON i x l0 l0 0l@l NA _]

/ h 9 11 it L OE.5 0F On D AM AGE f 0 F A',lt i f y TYPE DE$CFOP TION l l 1 h 9 30 PUH(lil f V Ng gq ,,

g ,;.sgEggj>esgr "' 79060503rr i f.K iii l4 i iw i i g :

l 53 tj 10 A. A. Hunstad p,m 612-388-4767 ym ,g pgg,y ,