LER 78-049/03L-0 on 781219:conduct of PT-39B Revealed 2 Snubbers W/Fluid Levels Less than Target Level.Caused by Leaking Tube Fittings
ML18113A760
Person / Time
Site: Surry Dominion icon.png
Issue date: 01/02/1979
From: Baucom T
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18113A757 List:
References
LER-78-049-03L, LER-78-49-3L, NUDOCS 7901090234
Download: ML18113A760 (2)


Text

m:ic FORr..i 366 U.S. NUCLEAR REGULATORY COMMISSION

{7-77)

-ICENSEE EVENT REPORT e CONTROL Ei LOCK: ~I-~~--'----'---'--......jl6 G) 1 (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION}

~

7 8 IV I A Is IP Is 11 JG)I o lo I - Io Io Io Io I o I - lo I o 101 41 11 11 11 1181 I I G) 9 LICENSEE COOE 14

  • 1S LICENSE NUMBER
  • 25 26 LICENSE TYPE JO 57 CAT 56 CON'T

[ITQ 7 B

~~~~~ L!:J© I o I s I o I o I o I 2 I s I o 101 *1 12 I 1 I 9 I 7 I s IG) Gi w Lo~~ ~.! G) 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 RE?OllT D'ATE oO EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

jWith the unit at cold shutdown, conduct of PT-39B reveale_d two snubbers with fluid levels less than target level. An engineering eva'iuation determined these snubbers

[ill] I.

~ Ito be inoperable. This event is reportable in accordance with T.S. 6.6.2.b.(2). Unit!

[III] 1 operation was normal from startup to shutdo,~). The health and safety of the public

[IT[) !were not affected.

[IT[]

7 8 9 80 SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

~8 [Z I ZI@ ~@ ~@ I SI u1 Pl 01 RI Tl@ t.E.J@ l£_]@

7 9 10 11 12 13 iS 19 20 SEQUENTIAL OCCUR REN.CE RE?ORT REVISION

@ L::R/RO CVENTYEAR REPORT NO. CODE TYPE NO.

REPORT NUMBER I7 j 8/ L=.l 10 j4 !9 I I/I 10 13 J l2:J L=J ~

21 22 23 24 26 27 28 29 30 31 32 ACTION, FUTURE EFFECT SHUTDOWN {22) ATTACHMENT NPRD-4 PRIME COMP . COM?ONENT

  • 1cKE1@f'zo1@

33 34 or~tl@

35 MrzT@

36 l O 100,os.

37

%I 40 SU,yll@

41 FORM :;us.

LJ SUPPLIER

~@

MANUFACTURER I I I 2 10 I 7 j@)

42 43 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

jThe cause of the low fluid levels was leaking tube fittings. One snubber was re-OJJJ !placed and one was repaired and restored. to operable condition. Tube fittings are a part of the visual acceptance criteria for surveillance of snubbers: All snubbers

!JJJJ .

' will be inspected prior to unit startup.

I ITEia 1 g 80 FACILITY METHOD OF A32 STATUS  % POWER OTHER STATUS DISCOVERY DISCOVERY DESCRIPTION 1.::.:;J

~ ~@ IO I O ! 0 l@I___NA_ _ ___ ~@)~1--'E_n'-'-'g~i_n_e_e_r_'s__o_b~s~e~r_v~a~t~i-*~o~n--'-------~

8 e 10 12 11 44 45 46 80 ACT1VITY CONTENT Q\

RELEASED OF RELEASE AMOUNT OF ACTIVITY '2_V . _LOCATION OF RELEASE @

l2:fila tu @ I z I@) I NA NA 1 s 10

?ERSONNEL EXPOSURES NUMBER Q TYPE 11 DESCRIPTION 39 f 44 45 80 EI2J 10 10 10 !~@,___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _____.

7 8 9 11 12 13 80 PERSONNEL INJURIES ,;":;\

NUMBER,. DESCRIPTION6 NA

~ I0 lu lu l@.____________________________ ---J 7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY '4:)\

TYPE DESCRIPTION ~

NA ITli] ~@

7 891 ~a--------------------- 0 090

- - --~-u------------------a~o 1ssu:~~~;;CRIPTION@ 79 1 ,I-, 3-, NRC USE ON Ly "'

~ ~o.________NA_ _ _ _ _ _ _ _ _ _ _ _ _ _~ 11 11 11 1 11 11 r ~

7 8 9 10 68 69 BO ;

T. L. Baucom (804) 357-3184 0 NAME OF P R E P A R E R - - - - - - - - - - - - - - - - - - ll.

PHONE:-------------

W\ttachment, page 1 of 1)

Surry Power Station, Unit Docket No: 50-280 Report No: 78-049/0JL-0 Event Date: 12/19/78 Title of Report: Inoperable Snubbers

1. Description of Event:

With the unit at cold shutdown, conduct of PT-39B revealed two snubbers, 1-RC-HSS-119 and 1-RC-HSS-135, with fluid levels less than target level. An engineering ~valuation on 12/19/78 determined these snubbers to be inoperable.

This event is reportable in accordance with Tech. Spec. 6.6.2.b.(2).

2. Probable Consequences of Event:

Since two snubbers represent a very small percentage of the total seismic restraint installation and since these restraints are provided for a low proba-bility event, and unit operation was normal from startup to shutdown, the health and safety of the public were not affected.

3 *. Cause of Event:

The cause of the low fluid levels was leaking tube fittings.

4. Immediate Corrective Action:

Snubber l-RC-HSS-119 was replaced with a Q.C. certified shop spare. The leaking fitting on snubber 1...:RC-HSS-135 was repaired and the reservoir level was restored to the proper level.

5. Subsequent Corrective Action:

Prior to *.unit startup, all snubbers will be verified operable by visual inspection criteria.

6. Action Taken to Prevent Recurrence:

Tube fittings are a part of the visual acceptance criteria for surveillance of snubbers. All snubbers will be inspected prior to unit startup.

7. Generic Implications:

The generic implications are those associated with hydraulic systems in general, i.e., leakage, seal life, environmental compatability, etc. These matters are state-of-the-art problems.