Category:Letter
MONTHYEAR05000395/LER-2024-002, Loss of Control Room Emergency Filtration System2024-10-15015 October 2024 Loss of Control Room Emergency Filtration System ML24290A1052024-10-0707 October 2024 Core Operating Limits Report VCSNS Unit 1 Cycle 29, Revision 0 ML24274A1942024-09-26026 September 2024 (Vcsns), Unit 1 Subsequent License Renewal Application (SLRA) First 10 CFR 54.21(b) Annual Amendment IR 05000395/20244042024-09-26026 September 2024 Cyber Security Inspection Report 05000395-2024404 - Public ML24267A0542024-09-23023 September 2024 Clarification Regarding Area of Potential Effect for the Subsequent Operating License Renewal for Virgil C. Summer Nuclear Station Fairfield County, South Carolina (SHPO Project Number: 22-EJ0147) (Docket Number: 50-395) ML24267A0642024-09-23023 September 2024 Clarification Regarding Area of Potential Effect for the Subsequent Operating License Renewal for Virgil C. Summer Nuclear Station Fairfield County, South Carolina (SHPO Project Number: 22-EJ0147) (Docket Number: 50-395) ML24267A0592024-09-23023 September 2024 Clarification Regarding Area of Potential Effect for the Subsequent Operating License Renewal for Virgil C. Summer Nuclear Station Fairfield County, South Carolina (SHPO Project Number: 22-EJ0147) (Docket Number: 50-395) ML24267A0552024-09-23023 September 2024 Clarification Regarding Area of Potential Effect for the Subsequent Operating License Renewal for Virgil C. Summer Nuclear Station Fairfield County, South Carolina (SHPO Project Number: 22-EJ0147) (Docket Number: 50-395) IR 05000395/20244022024-09-10010 September 2024 Security Baseline Inspection Report 05000395/2024402 IR 05000395/20240052024-08-22022 August 2024 Updated Inspection Plan for Virgil C. Summer Nuclear Station - Report 05000395/2024005 ML24190A4012024-08-19019 August 2024 Request for Withholding Information from Public Disclosure Regarding the Subsequent License Renewal Application - Dominion Energy Letter Dated May 30, 2024 IR 05000395/20240022024-08-12012 August 2024 Integrated Inspection Report 05000395/2024002 ML24180A0062024-08-0505 August 2024 Issuance of Amendment No. 227 to Modify Technical Specification 3.8.3.1 to Increase Completion Time for 120-Volt A.C. Vital Busses ML24218A3002024-08-0101 August 2024 Environmental Review Response to NRC Requests for Additional Information and Response to NRC Requests for Confirmation of Information Set 1 ML24158A3882024-07-31031 July 2024 Issuance of Amendment No. 226 to Change Emergency Plan Staff Augmentation Times and Relocate Emergency Operations Facility ML24162A3292024-07-0505 July 2024 Letter to E Carr - V.C. Summer Unit 1 - Summary of the May 2024 Audit Regarding the Environmental Review of the Subsequent License Renewal Application IR 05000395/20240112024-06-26026 June 2024 – Comprehensive Engineering Team Inspection Report 05000395/2024011 ML24178A2422024-06-25025 June 2024 2023 Annual Report of Emergency Core Cooling System (ECCS) Model, Changes Pursuant to the Requirements of 10 CFR 50.46 ML24178A1192024-06-25025 June 2024 Update to License Amendment Request- Inverter Allowed Outage Time (AOT) Extension ML24177A1382024-06-25025 June 2024 Aging Management Audit Report- VC Summer, Unit 1 - Subsequent License Renewal Application ML24177A2792024-06-20020 June 2024 Preparation and Scheduling of Operator Licensing Examinations ML24171A0152024-06-17017 June 2024 Update to Subsequent License Renewal Application (SLRA) Response to NRC Request for Additional Information Set 2 Safety Review ML24157A3352024-06-0606 June 2024 – Notification of an NRC Cybersecurity Baseline Inspection (NRC Inspection Report 05000395-2024404 and Request for Information ML24155A2042024-05-31031 May 2024 Proposed Alternative Request RR-24-123, Containment Unbonded Post-Tensioning System Inservice Inspection Requirements ML24155A1462024-05-30030 May 2024 Update to Subsequent License Renewal Application (SLRA) -Response to NRC Request for Additional Information Set 1 Response to NRC Request for Confirmation of Information Set 1 and Supplement 3 ML24143A1792024-05-22022 May 2024 Special Report 2024-001-01 for Virgil C. Summer Nuclear Station (Vcsns), Unit 1, Waste Gas System Inoperability ML24141A2822024-05-20020 May 2024 (Vcsns), Unit 1 - License Amendment Request - Emergency Response Organization (ERO) Augmentation Time Change, Emergency Operations Facility Relocation and Other Emergency Plan Changes IR 05000395/20240012024-05-10010 May 2024 Integrated Inspection Report 05000395/2024001 ML24129A2002024-05-0606 May 2024 Update to Subsequent License Renewal Application, Supplement 2 IR 05000395/20240402024-05-0101 May 2024 95001 Supplemental Inspection Report 05000395/2024040 and Follow-Up Assessment Letter ML24120A2072024-04-29029 April 2024 Submittal of Annual Radiological Environmental Operating Report ML24121A1002024-04-29029 April 2024 Response to Request for Additional Information Regarding Alternative Request RR-5-V2 ML24116A2052024-04-23023 April 2024 Annual Radioactive Effluent Release Report ML24109A1792024-04-19019 April 2024 Aging Management Audit Plan Regarding the Subsequent License Renewal Application Review ML24108A0392024-04-18018 April 2024 Letter to E Carr-V.C. Summer Unit 1- Regulatory Audit Regarding the Environmental Review of the Subsequent License Renewal Application ML24108A1432024-04-17017 April 2024 (Vcsns), Unit 1, Automatic Actuation of B Emergency Diesel Generator ML24108A0672024-04-17017 April 2024 Submittal of Summary for Condition of the Service Water Intake Structure Provided in Accordance with License Condition 2.C.5.d ML24100A7312024-04-0909 April 2024 Personnel Exposure and Monitoring Annual Report ML24095A2072024-04-0101 April 2024 Update to Subsequent License Renewal Application (SLRA) Supplement 1 ML24088A2062024-03-26026 March 2024 Annual Operating Report ML24087A2182024-03-26026 March 2024 (Vcsns), Unit 1 - License Amendment Request - Emergency Response Organization (ERO) Augmentation Time Change, Emergency Operations Facility Relocation and Other Emergency Plan Changes - Response to Request. ML24087A2262024-03-26026 March 2024 License Amendment Request - Inverter Allowed Outage Time Extension Response to Request for Additional Information ML24067A0232024-03-0707 March 2024 (Vcsns), Unit 1 - Readiness for 95001 Supplemental Inspection; EA-23-093 IR 05000395/20230062024-02-28028 February 2024 Annual Assessment Letter for Virgil C. Summer Nuclear Station - Report 05000395/2023006 IR 05000395/20244032024-02-27027 February 2024 Security Baseline Inspection Report 05000395/2024403 ML24057A1132024-02-22022 February 2024 Special Report 2024-001 Waste Gas System Inoperability ML24051A0112024-02-20020 February 2024 Fws to NRC, List of Threatened and Endangered Species That May Occur in Proposed Project Location or May Be Affected by Proposed Project for V.C. Summer SLR ML24057A0612024-02-19019 February 2024 and Virgil C. Summer Power Nuclear Stations - Nuclear Property Insurance Coverage ML24032A3062024-02-15015 February 2024 Exemption from Select Requirements of 10 CFR Part 73 - Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting ML24040A1802024-02-12012 February 2024 Notification of NRC Supplemental Inspection (95001) and Request for Information 2024-09-26
[Table view] Category:License-Application for Facility Operating License (Amend/Renewal) DKT 50
MONTHYEARML24274A1942024-09-26026 September 2024 (Vcsns), Unit 1 Subsequent License Renewal Application (SLRA) First 10 CFR 54.21(b) Annual Amendment ML24129A2002024-05-0606 May 2024 Update to Subsequent License Renewal Application, Supplement 2 ML24095A2072024-04-0101 April 2024 Update to Subsequent License Renewal Application (SLRA) Supplement 1 ML23233A1762023-08-17017 August 2023 Application for Withholding Proprietary Information from Public Disclosure Pursuant to 10 CFR 2.390 ML23233A1742023-08-17017 August 2023 Appendix E, Applicants Environmental Report Subsequent Operating License Renewal License Stage ML23233A1752023-08-17017 August 2023 Application for Subsequent Renewed Operating License ML23233A1722023-08-17017 August 2023 Application for Subsequent License Renewal August 2023 ML23159A2332023-06-0808 June 2023 License Amendment Request - Emergency Response Organization Augmentation Time Change, Emergency Operations Facility Relocation and Other Emergency Plan Changes ML22242A1642022-08-31031 August 2022 Vcsummer, Unit 1 FOL - Amd 222 Corrected Pages ML22146A0272022-05-25025 May 2022 Application to Revise Technical Specifications to Adopt TSTF-554, Revise Reactor Coolant. ML22115A1042022-04-22022 April 2022 License Amendment Request- Technical Specifications Nozzle Blockage Testing Requirement Change for Reactors Building Spray System ML22115A0602022-04-22022 April 2022 Application for Technical Specification Change TSTF-491, Removal of Main Steam and Main Feedwater Valve Isolation Times from Technical Specifications Using Consolidated Line Item Improvement Process ML21147A3772021-05-27027 May 2021 (Vcsns), Unit 1 - Proposed Amendment to Relocate Unit Staff Qualification from Technical Specifications to Quality Assurance Program Description (QAPD) ML21102A1272021-04-0909 April 2021 (Vcsns), Unit 1 - Application for Technical Specification Change Regarding Risk Informed Justification for the Relocation of Specific Surveillance Frquency Requirements to Licensee-Controlled Program ML21063A0012021-04-0909 April 2021 Issuance of Amendment No. 218 to Modify Techncial Specifcation 3.6.4, Contaiment Isolation Valves ML20121A1852020-04-30030 April 2020 License Amendment Request LAR-20-142 - Request for Technical Specification Change Technical Specification 3.6.4, Containment Isolation Valves ML19323E9522019-11-19019 November 2019 (Vcsns), Unit 1 License Amendment Request to Revise the Company Name - Supplement ML19053A5442019-02-22022 February 2019 (Vcsns), Unit 1 - Supplemental Letter to License Amendment Request - LAR-16-00644 License Amendment Request - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.2 RC-18-0136, (Vcsns), Unit 1 - Request to Remove the Expired One-Time Extension to Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation and to Remove the Index from Technical Specifications (LAR-18-04683)2018-12-12012 December 2018 (Vcsns), Unit 1 - Request to Remove the Expired One-Time Extension to Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation and to Remove the Index from Technical Specifications (LAR-18-04683) RC-18-0067, (Vcsns), Unit 1 - License Amendment Request - LAR-16-00644 - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.22018-10-0808 October 2018 (Vcsns), Unit 1 - License Amendment Request - LAR-16-00644 - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.2 RC-18-0112, (Vcsns), Unit 1 - Request for License Amendment to Virgil C. Summer Nuclear Station Technical Specification 3.8.2, D.C. Sources - Operating, Surveillance Requirements 4.8.2.1.B.2 and 4.8.2.1.C.32018-09-27027 September 2018 (Vcsns), Unit 1 - Request for License Amendment to Virgil C. Summer Nuclear Station Technical Specification 3.8.2, D.C. Sources - Operating, Surveillance Requirements 4.8.2.1.B.2 and 4.8.2.1.C.3 RC-18-0113, (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-08-31031 August 2018 (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0091, License Amendment Request - LAR-16-01490 National Fire Protection Association Standard 805 Program Revisions2018-08-29029 August 2018 License Amendment Request - LAR-16-01490 National Fire Protection Association Standard 805 Program Revisions RC-18-0111, License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-08-24024 August 2018 License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0079, Vigil C. Summer Nuclear Station (Vcsns), Unit 1 - Request to Revise Technical Specifications to Correct an Administrative Error2018-06-29029 June 2018 Vigil C. Summer Nuclear Station (Vcsns), Unit 1 - Request to Revise Technical Specifications to Correct an Administrative Error RC-18-0060, (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error2018-05-30030 May 2018 (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error ML18092B5102018-03-29029 March 2018 (VCSNS) - Administrative License Amendment Request to Correct the Typographical Error in TS Table 6.2-1 Minimum Shift Crew RC-17-0107, (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change2017-10-0606 October 2017 (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change RC-16-0092, License Amendment Request LAR-12-02439, Technical Specification 3.5.4, Limiting Condition for Operation Refueling Water Storage Tank2016-08-29029 August 2016 License Amendment Request LAR-12-02439, Technical Specification 3.5.4, Limiting Condition for Operation Refueling Water Storage Tank RC-16-0059, License Amendment Request LAR 12-02439, Technical Specification Change Request for TS 3.5.4 Refueling Water Storage Tank (RWST)2016-04-28028 April 2016 License Amendment Request LAR 12-02439, Technical Specification Change Request for TS 3.5.4 Refueling Water Storage Tank (RWST) RC-16-0039, Exigent License Amendment Request - LAR (16-00848), Technical Specification Change Request for Emergency Feedwater System Limiting Condition for Operation 3.7.1.2 Action B - Response to Request for Additional..2016-03-0303 March 2016 Exigent License Amendment Request - LAR (16-00848), Technical Specification Change Request for Emergency Feedwater System Limiting Condition for Operation 3.7.1.2 Action B - Response to Request for Additional.. RC-15-0171, License Amendment Request - LAR-15-01424, Implementation of WCAP-15376-P-A, Revision 1 - Risk-Informed Assessment of the RTS and ESFAS Surveillance Test Intervals and Reactor Trip Breaker Test and Completion Times.2015-12-16016 December 2015 License Amendment Request - LAR-15-01424, Implementation of WCAP-15376-P-A, Revision 1 - Risk-Informed Assessment of the RTS and ESFAS Surveillance Test Intervals and Reactor Trip Breaker Test and Completion Times. RC-15-0113, License Amendment Request LAR-08-001, 62Request to Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF)-523, Generic Letter 2008-01, Managing Gas Accumulation2015-09-29029 September 2015 License Amendment Request LAR-08-001, 62Request to Revise Technical Specifications to Adopt Technical Specifications Task Force (TSTF)-523, Generic Letter 2008-01, Managing Gas Accumulation RC-15-0109, License Amendment Request - LAR 14-02981, Proposed Revision to Technical Specification 6.0, Administrative Controls.2015-07-22022 July 2015 License Amendment Request - LAR 14-02981, Proposed Revision to Technical Specification 6.0, Administrative Controls. ML14261A2762014-09-18018 September 2014 Draft September 23, 2014, Category 1 Public Meeting with V. C. Summer - Draft License Amendment Related to Approval of the Technical Support Center RC-14-0112, License Amendment Request - LAR-12-04269 License Basis Changes in Steam Generator Tube Rupture Analysis2014-08-27027 August 2014 License Amendment Request - LAR-12-04269 License Basis Changes in Steam Generator Tube Rupture Analysis RC-14-0032, Virgil C. Summer Unit 1, License Amendment Request LAR-14-02392, Request for NRC Approval of Proposed Changes to Emergency Action Levels. Attachment I: Analysis of Proposed Emergency Action Levels Enclosed2014-04-0707 April 2014 Virgil C. Summer Unit 1, License Amendment Request LAR-14-02392, Request for NRC Approval of Proposed Changes to Emergency Action Levels. Attachment I: Analysis of Proposed Emergency Action Levels Enclosed ML14122A1562014-04-0707 April 2014 License Amendment Request LAR-14-02392, Request for NRC Approval of Proposed Changes to Emergency Action Levels. Attachment I: Analysis of Proposed Emergency Action Levels Enclosed RC-13-0188, License Amendment Request - LAR-13-01414, License Amendment Request to Change the Completion Date of Implementation Milestone 8 Response to Request for Additional Information2013-12-20020 December 2013 License Amendment Request - LAR-13-01414, License Amendment Request to Change the Completion Date of Implementation Milestone 8 Response to Request for Additional Information ML13095A1092013-04-0303 April 2013 License Amendment Request - LAR (13-00705) Technical Specification Change to Extend Integrated Leak Rate Test Frequency to 15 Years RC-13-0037, Virgil C. Summer Nuclear Station, Unit 1, License Amendment Request - LAR (13-00705) Technical Specification Change to Extend Integrated Leak Rate Test Frequency to 15 Years2013-04-0303 April 2013 Virgil C. Summer Nuclear Station, Unit 1, License Amendment Request - LAR (13-00705) Technical Specification Change to Extend Integrated Leak Rate Test Frequency to 15 Years RC-13-0034, License Amendment Request - LAR (11-02281) Technical Specification Change to Add an Exception to Specification 3.0.4 in Technical Specification 3/4.7.6 Control Room Emergency Filtration System (CREFS)2013-04-0303 April 2013 License Amendment Request - LAR (11-02281) Technical Specification Change to Add an Exception to Specification 3.0.4 in Technical Specification 3/4.7.6 Control Room Emergency Filtration System (CREFS) RC-13-0047, License Amendment Request - LAR 12-03567, Application to Revise Tech Specs to Adopt TSTF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection, Using Consolidated Line Item Improvement..2013-04-0202 April 2013 License Amendment Request - LAR 12-03567, Application to Revise Tech Specs to Adopt TSTF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection, Using Consolidated Line Item Improvement.. RC-13-0048, License Amendment Request - LAR 12-06014 Changes to Snubber Surveillance Requirements2013-04-0202 April 2013 License Amendment Request - LAR 12-06014 Changes to Snubber Surveillance Requirements RC-13-0037, Permanent ILRT Interval Extension Risk Impact Assessment2013-03-0101 March 2013 Permanent ILRT Interval Extension Risk Impact Assessment ML12030A0352012-02-22022 February 2012 Issuance of Amendment Regarding Reporting Requirements ML12047A1462012-02-0101 February 2012 NPDES Permits No. SC0030856 Renewal Application RC-11-0157, License Amendment Request LAR 11-04821, Request for Prior NRC Approval to Exempt Five-High-Head Safety Injection Containment Isolation Valves from Local Leak Rate Testing Requirements2011-10-12012 October 2011 License Amendment Request LAR 11-04821, Request for Prior NRC Approval to Exempt Five-High-Head Safety Injection Containment Isolation Valves from Local Leak Rate Testing Requirements RC-11-0063, License Amendment Request - LAR 11-01774, Application to Eliminate License Condition 2.G.1 Requiring Reporting of Violations of Section 2.C of the Operating License Using the Consolidated Line Item Improvement Process (CLIIP)2011-08-23023 August 2011 License Amendment Request - LAR 11-01774, Application to Eliminate License Condition 2.G.1 Requiring Reporting of Violations of Section 2.C of the Operating License Using the Consolidated Line Item Improvement Process (CLIIP) RC-11-0104, License Amendment Request - LAR (10-03107) Proposed Change in Administrative Controls Section to Allow the Use of Westinghouse WCAP-12472-P-A, Addendum 1-A2011-08-11011 August 2011 License Amendment Request - LAR (10-03107) Proposed Change in Administrative Controls Section to Allow the Use of Westinghouse WCAP-12472-P-A, Addendum 1-A 2024-09-26
[Table view] Category:Technical Specifications
MONTHYEARML24180A0062024-08-0505 August 2024 Issuance of Amendment No. 227 to Modify Technical Specification 3.8.3.1 to Increase Completion Time for 120-Volt A.C. Vital Busses ML23317A2242023-11-0909 November 2023 (Vcsns), Unit 1 - License Amendment Request - Inverter Allowed Outage Time (AOT) Extension ML23072A0892023-05-0101 May 2023 (Amendments 346 & 286), North Anna 1 & 2 (Amnds 294 & 277), Surry 1 & 2 (Amnds 311 & 311), and Summer 1 (Amd 225) - Issuance of Amendments to Revise TSs to Adopt TSTF-554 Revise Reactor Coolant Leakage Requirements ML23012A0152023-02-21021 February 2023 Issuance of Amendment No. 224 to Change Nozzle Blockage Testing Requirement for Reactor Building Spray System ML22269A4342022-09-26026 September 2022 VC Summer Correction Letter to Amendment 166 - Enclosure - ML22269A4372022-09-26026 September 2022 Correction to Issuance of Amendment Related to Surveillance Requirement 4.0.5, Associated Basis, and Bases 3/4.4.2, 3/4.4.6, and 3/4.4.10 ML22115A1042022-04-22022 April 2022 License Amendment Request- Technical Specifications Nozzle Blockage Testing Requirement Change for Reactors Building Spray System ML21319A2622021-12-28028 December 2021 Issuance of Amendment No. 220 to Relocate Unit Staff Qualifications from Technical Specification to Quality Assurance Program Description ML21280A3282021-10-0707 October 2021 Application to Revise Technical Specifications to Adopt TSTF-569, Revision of Response Time Testing Definitions ML20156A3032020-06-0404 June 2020 License Amendment Request Update of Analytical Method to the Core Operating Limits Report with the Full Spectrum Loss of Coolant Accident Approach ML18253A1152018-10-0505 October 2018 Issuance of Amendment No. 212 Technical Specification Change Request for the Revision of the Surveillance Frequency of the Turbine Trip Functional Unit ML18092B5102018-03-29029 March 2018 (VCSNS) - Administrative License Amendment Request to Correct the Typographical Error in TS Table 6.2-1 Minimum Shift Crew RC-17-0175, Correction to Amendment No. 170 Request to Revise Technical Specifications to Correct Administrative Error2018-01-31031 January 2018 Correction to Amendment No. 170 Request to Revise Technical Specifications to Correct Administrative Error ML17206A4122017-10-0404 October 2017 Issuance of Amendment TSTF-411, Revision 1, Surveillance Test Interval Extensions for Components of the Reactor Protection System (WCAP-15376-P-A). ML16104A2952016-05-0606 May 2016 Issuance of Amendment to Adopt TSTF-523, Revision 2 ML16063A0902016-03-0909 March 2016 Issuance of Exigent Amendment Regarding Technical Specification 3.7.1.2 ML15208A0292015-10-15015 October 2015 Issuance of Amendment ML15170A0872015-08-18018 August 2015 Issuance of Amendment to Revise the Radiation Emergency Plan ML15063A3552015-04-13013 April 2015 Issuance of Amendment to Revise Emergency Action Levels to a Scheme Based on NEI 99-01, Revision 6 ML14287A2892015-02-11011 February 2015 Issuance of Amendment Regarding Transition to a Risk-Informed, Performance-Based Fire Protection Program in Accordance with 10 CFR 50.48(c) ML14122A3092014-05-29029 May 2014 Issuance of Amendment 198 Regarding the Cyber Security Plan Implementation Schedule Milestone 8 ML14030A3742014-03-11011 March 2014 Issuance of Amendment for Technical Specification Change Related to Control Room Emergency Filtration System ML13354B6432014-02-0606 February 2014 Issuance of Amendment for the Technical Specification Change Related to Snubber Surveillance Requirements ML13326A2042014-02-0505 February 2014 Issuance of Amendment Extending Integrated Leak Rate Test Interval RC-13-0034, License Amendment Request - LAR (11-02281) Technical Specification Change to Add an Exception to Specification 3.0.4 in Technical Specification 3/4.7.6 Control Room Emergency Filtration System (CREFS)2013-04-0303 April 2013 License Amendment Request - LAR (11-02281) Technical Specification Change to Add an Exception to Specification 3.0.4 in Technical Specification 3/4.7.6 Control Room Emergency Filtration System (CREFS) RC-13-0047, License Amendment Request - LAR 12-03567, Application to Revise Tech Specs to Adopt TSTF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection, Using Consolidated Line Item Improvement..2013-04-0202 April 2013 License Amendment Request - LAR 12-03567, Application to Revise Tech Specs to Adopt TSTF-510, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection, Using Consolidated Line Item Improvement.. ML12146A0172012-05-30030 May 2012 Issuance of Amendment on Beacon Core Monitoring and Operations Support System RC-11-0063, License Amendment Request - LAR 11-01774, Application to Eliminate License Condition 2.G.1 Requiring Reporting of Violations of Section 2.C of the Operating License Using the Consolidated Line Item Improvement Process (CLIIP)2011-08-23023 August 2011 License Amendment Request - LAR 11-01774, Application to Eliminate License Condition 2.G.1 Requiring Reporting of Violations of Section 2.C of the Operating License Using the Consolidated Line Item Improvement Process (CLIIP) RC-11-0104, License Amendment Request - LAR (10-03107) Proposed Change in Administrative Controls Section to Allow the Use of Westinghouse WCAP-12472-P-A, Addendum 1-A2011-08-11011 August 2011 License Amendment Request - LAR (10-03107) Proposed Change in Administrative Controls Section to Allow the Use of Westinghouse WCAP-12472-P-A, Addendum 1-A RC-11-0062, V. C. Summer, License Amendment Request - LAR 04-02961, License Amendment Request for Slave Relay Surveillance Testing2011-04-18018 April 2011 V. C. Summer, License Amendment Request - LAR 04-02961, License Amendment Request for Slave Relay Surveillance Testing RC-11-0006, License Amendment Request - LAR-10-03108, Proposed Change to Relocate Administrative Control Requirements Related to Quality Assurance and Submittal of Quality Assurance Program Description (QAPD)2011-03-18018 March 2011 License Amendment Request - LAR-10-03108, Proposed Change to Relocate Administrative Control Requirements Related to Quality Assurance and Submittal of Quality Assurance Program Description (QAPD) RC-10-0092, License Amendment Request (LAR 10-02033), Changes to Emergency Diesel Generator Surveillance Test Requirements2010-11-11011 November 2010 License Amendment Request (LAR 10-02033), Changes to Emergency Diesel Generator Surveillance Test Requirements ML1001103772010-03-22022 March 2010 Issuance of Amendment Regarding: Use of Optimized Zirlo Fuel Rod Cladding RC-08-0007, License Amendment Request - LAR 03-01931-20, Application to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process2008-01-17017 January 2008 License Amendment Request - LAR 03-01931-20, Application to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process ML0713705092007-05-15015 May 2007 Technical Specifications, Issuance of Amendment Regarding Steam Generator Tube Integrity RC-06-0199, License Amendment Request - LAR 05-3262, Changes to Emergency Diesel Generator Specification2006-11-21021 November 2006 License Amendment Request - LAR 05-3262, Changes to Emergency Diesel Generator Specification ML0630700682006-11-0202 November 2006 Technical Specifications Pages Re Alternate AC Power Supply ML0630000262006-10-24024 October 2006 Technical Specifications, Implementing Approved Changes in Probabilistic Risk Analysis of the RPS and ESFAS Test Times and Completion Times. ML0627002792006-09-0707 September 2006 V.C. Summer, Tech Spec Pages for Amendment 176 Regarding Best Estimate Loss-of-Coolant Accident Analyses Methodology RC-06-0084, License Amendment Request - LAR 05-3594, Steam Generator Tube Integrity2006-05-24024 May 2006 License Amendment Request - LAR 05-3594, Steam Generator Tube Integrity ML0614204982006-05-0404 May 2006 Technical Specifications, Administrative Controls ML0535300472005-12-13013 December 2005 Enclosure, Amd MC7375, Reactor Coolant System Pressure-Temperature Limits ML0522402792005-08-10010 August 2005 Operating License, License Amendment Request- LAR 04-0440, Emergency Feedwater System Pump Testing Criteria RC-05-0090, License Amendment Request Re Reactor Coolant System - Heatup/Cooldown Curves2005-06-22022 June 2005 License Amendment Request Re Reactor Coolant System - Heatup/Cooldown Curves ML0513902262005-05-0909 May 2005 Enclosure, Amd MC3308, Extending the Inspection Interval for Reactor Coolant Pump Flywheels RC-05-0041, License Amendment Request (LAR 03-1931-24) Adoption of TS Task Force (TSTF) Traveler-287, Revision 5, Ventilation System Envelope Allowed Outage Time2005-03-0909 March 2005 License Amendment Request (LAR 03-1931-24) Adoption of TS Task Force (TSTF) Traveler-287, Revision 5, Ventilation System Envelope Allowed Outage Time ML0410404932004-04-0505 April 2004 Technical Specifications, Revision to Allowed Outage Time for Engineered Safety Features Actuation System Instrumentation ML0334503692003-12-15015 December 2003 Tech Spec Pages for Amendment 165 One-Time Extension of Steam Generator Inspection Interval ML0330400312003-10-29029 October 2003 Technical Specification Pages for Virgil C. Summer Nuclear Station, Unit 1, Amendment No. 165 ML0327513912003-09-26026 September 2003 Technical Specification for Virgil C. Summer Nuclear Station, Unit 1 - Issuance of Amendment 164, Revising the Action Statement and Surveillance Requirement for the Emergency Diesel Generators 2024-08-05
[Table view] |
Text
George A. Lippard Vice President, Nuclear Operations 803.345.4810 A SCANA COMPANY March 29, 2018 RC-18-0034 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555
Dear Sir / Madam:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)
DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ADMINISTRATIVE LICENSE AMENDMENT REQUEST TO CORRECT THE TYPOGRAPHICAL ERROR IN TS TABLE 6.2-1 "MINIMUM SHIFT CREW"
References:
- 1. Letter from D. A. Nauman, "Virgil C. Summer Nuclear Station, Docket No.
50/395, Operating License No. NPF-12, Technical Specifications, Deletion of Organization Charts and Revision of Training Requirements" dated July 6, 1987 (ADAMS Accession No. 8707140094 (Legacy Library))
- 2. Letter from J. J. Hayes, NRC, to O. S. Bradham, "Regarding Removal of Organization Charts and Various Administrative Changes (TAC Nos. 65778 and 67340) and Deletion of Fire Protection Technical Specifications (TAC NO.
65060)," dated July 24, 1989
- 3. Letter from Gatlin, "Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Docket No. 50-395 Operating License No. NPF-12 License Amendment Request - LAR 14-02981 Proposed Revision to Technical Specification 6.0 "Administrative Controls", dated July 22, 2015 (ML15205A291)
- 4. Letter from R. J. Pascarelli, NRC, to T. D. Gatlin VCSNS, Letter to NRC, "Issuance of Amendment (CAC NO. MF6503),dated October 15, 2015 (ML15208A029)
- 5. Proposed Guidance for Correction of Technical Specification Typographical Errors, SECY 96-238, dated November 19, 1996 (ADAMS Accession No.
9611250030 (Legacy Library))
This letter requests Nuclear Regulatory Commission (NRC) approval of a correction of typographical errors in the VCSNS Technical Specifications (TS), which were inadvertently introduced during License Amendment 79 (Reference 1) and License Amendment 202 (Reference 3).
These typographical errors were not addressed in the notice to the public, nor reviewed by the NRC, and therefore, fall within the scope of the guidance provided by SECY-96-238 (Reference 5, ADAMS Accession No. 9611250030 (Legacy Library)) for corrections.
V. C. Summer Nuclear Station
Document Control Desk RC-18-0034 CR-16-03840 Page 2 of 2 Attachment I describes the typographical errors and corrections. Attachment II provides the Amendment 202 page as issued, with the requested corrections noted. Attachment III contains the corrected Amendment 202 page.
This document contains no new commitments.
If you have any questions about this submittal, please contact Michael S. Moore at (803) 345-4752.
Very truly yours, GeSrge A. Lippard WHK/GAL/RP Attachments:
Attachment I: Description of Technical Specification Typographical Errors Attachment II: Marked Up Technical Specification Page Attachment III: Clean Technical Specification Page cc: S. A. Williams Michael Mahoney NSRC RTS (CR-16-03840)
File (813.20)
PRSF (RC-18-0034)
Document Control Desk Attachment I RC-18-0034 CR-16-03840 Page 1 of 3 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)
DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ATTACHMENT I Description of Technical Specification Typographical Errors
Document Control Desk Attachment I RC-18-0034 CR-16-03840 Page 2 of 3 A. Requested Action Consistent with the information contained in SECY-96-238, Proposed Guidance for Correction of Technical Specification Typographical Errors, South Carolina Electric and Gas (SCE&G), the licensee for Virgil C. Summer Nuclear Station (VCSNS), is requesting the correction of two inadvertent typographical errors that were introduced into the VCSNS Technical Specifications (TS).
B. Typographical Error One typographical error was introduced into the VCSNS TS during implementation of License Amendment 79 (Reference 1), and two were introduced during implementation of License Amendment 202 (Reference 4). The specification of the errors and proposed corrections are described below:
Twice in Table 6.2-1, the acronym for Control Room Supervisor is incorrectly shown as being CRF. The correct acronym is CRS. Therefore, CRF should be replaced with CRS.
This error was not introduced in the original License Amendment Request (LAR)
Mark-up pages (Reference 1) that were submitted to the U. S. Nuclear Regulatory Commission (NRC) and was, therefore, not noticed to the public, nor approved by the NRC during review and approval of Amendment 79. This error was introduced on the clean pages issued after NRC review.
In Table 6.2-1, the acronyms for Reactor Operator and Auxiliary Operator are incorrectly shown as being RD and AD, respectively. The correct acronyms are RO and AO. Therefore, RD and AD should be respectively replaced by RO and AO.
These errors were not introduced in the original License Amendment Request (LAR)
Mark-up pages (Reference 3) that were submitted to the U. S. Nuclear Regulatory Commission (NRC) and were therefore, not noticed to the public, nor approved by the NRC during review and approval of Amendment 202. This error was introduced on the clean pages issued after NRC review.
C. Corrections to the Affected TS Page SECY 96-238, (Reference 5) provides guidance to correct inadvertent typographical errors in the TS pages. Specifically:
"...the case in which the staff or licensee can demonstrate that the error was introduced inadvertently in a particular license amendment and that the erroneous change was not addressed in the notice to the public nor reviewed by the staff. Under these limited circumstances, the change that introduced the typographical error was
Document Control Desk Attachment I RC-18-0034 CR-16-03840 Page 3 of 3 not a proper amendment to the license because it was neither addressed in the notice nor reviewed, and correction of the typographical error is not a "change" to the TS. Accordingly, the typographical error may be corrected by a letter to the licensee from the NRC staff, instead of an amendment to the license. ..."
The typographical errors described above were not noticed to the public, nor were they reviewed by the NRC as part of the application amendment process. Therefore, these errors may be corrected without a license amendment.
Accordingly, upon approval from the NRC, a corrected TS Page 6-2 will be issued to all holders of controlled TS.
Document Control Desk Attachment II RC-18-0034 CR-16-03840 Page 1 of 2 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)
DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ATTACHMENT II Marked Up Technical Specification Page
TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION SUMMER UNIT 1 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODES 1. 2, 3, &4 MODES 5 & 6 SM 1 1 CRS > GRE 1 None RO 2 1 AO 2 1 STA 1 None SM - Shift Manager with a Senior Reactor Operators License on Unit 1 CRS > GRE - Control Room Supervisor with a Senior Reactor Operators License on Unit 1 RO l> RG - Individual with a Reactor Operators License on Unit 1 AO > A - Auxiliary Operator STA - Shift Technical Advisor Except for the Shift Manager, the Shift Crew Composition may be one less than the minimum requirements of Table 6.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the Shift Crew Composition to within the minimum requirements of Table 6.2-1. This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.
During any absence of the Control Room Supervisor from the Control Room while the unit is in MODE 1, 2, 3 or 4, an individual (other than the Shift Technical Advisor) with a valid SRO license shall be designated to assume the Control Room command function. During any absence of the Shift Manager from the Control Room while the unit is in MODE 5 or 6, an individual with a valid RO or SRO license shall be designated to assume the Control Room command function.
SUMMER-UNIT 1 6-2 Amendment No. 18, 58, 79, 202
Document Control Desk Attachment III RC-18-0034 CR-16-03840 Page 1 of 2 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)
DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ATTACHMENT III Clean Technical Specification Page
TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION SUMMER UNIT 1 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODES 1,2. 3. &4 MODES 5 & 6 SM 1 1 CRS 1 None RO 2 1 AO 2 1 STA 1 None SM - Shift Manager with a Senior Reactor Operators License on Unit 1 CRS - Control Room Supervisor with a Senior Reactor Operators License on Unit 1 RO - Individual with a Reactor Operators License on Unit 1 AO - Auxiliary Operator STA - Shift Technical Advisor Except for the Shift Manager, the Shift Crew Composition may be one less than the minimum requirements of Table 6.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the Shift Crew Composition to within the minimum requirements of Table 6.2-1. This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.
During any absence of the Control Room Supervisor from the Control Room while the unit is in MODE 1, 2, 3 or 4, an individual (other than the Shift Technical Advisor) with a valid SRO license shall be designated to assume the Control Room command function. During any absence of the Shift Manager from the Control Room while the unit is in MODE 5 or 6, an individual with a valid RO or SRO license shall be designated to assume the Control Room command function.
SUMMER-UNIT 1 6-2 Amendment No. 18, 58, 79, 202