CATEGORY 1 REGULA'JY TMFORMATTOM DTSTRTBUTICYSTEM (RTDS)

ACCESSION NBR:9806160117 FACIL:50.-250 Turkey Point DOC.DATE: 98/06/09 NOTARIZED: NO Plant, Unit 3, Florida Power and Light C 05000250 DOCKET I AUTH.NAME AUTHOR AFFILIATION HOVEY, R. J'. Florida Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards LER 98-002-00 re 980513 discovery of potential LOCA-initiated electrical fault places which could place ECCS outside design basis.

SIZE:

A DISTRIBUTION CODE: IE22T COPIES RECEIVED:LTR ENCL TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc. T NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-3 PD 1 1 JABBOUR,K 1 1 0 INTERNAL: 2 2 AEOD/SPD/RRAB 1 1 R E CENTE 1 ' 1 NRR/DE/ECGB 1 1 NRR 1 NRR/DE/EMEB 1 1 NRR/DRCH/HHFB 1 1 NRR/DRCH/HICB 1 1 NRR/DRCH/HOLB 1 1 NRR/DRCH/HQMB 1 1 NRR/DRPM/PECB 1 1 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 RES/DET/EIB 1 1 RGN2 FILE 01 1 1 r

EXTERNAL: L ST LOBBY WARD 1 1 LITCO BRYCE,J H 1 1 D NOAC POORE,W. 1 1 NOAC QUEENER,DS 1 1 NRC PDR 1 1 NUDOCS FULL TXT 1 1 0 NOTE TO ALL '"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED: LTTR 24 ENCL 24

'PL JUN 09 1998 I.-98-139 10 CFR 50.73 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250, 50-251 Reportable Event: 98-002 Date of Event: May 13, 1998 ni 1 -Tnii 1 The attached Licensee Event Report is being submitted pursuant to the requirements of 10 CFR 50.73 to provide notification of the subject event.

Sincerely, R. J. Hovey Vice President Turkey Point Plant CLM Attachment cc: Regional Administrator, USNRC Region II Senior Resident Inspector, USNRC, Turkey Point Plant m06<60~<7 em6ae '.

PDR ADOCK 05000250 S

an FPL Group company