Forwards Revised TS Section 6.9.1.7, COLR, Clarifying References 4 & 6 by Adding Best Estimate LOCA to COLR & Documenting re-analysis Performed as Result of Revs to Large Break LOCA Methodology,As Discussed W/Nrc on 971117
ML17354A730
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 12/04/1997
From: Hovey R
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17354A731 List:
References
L-97-295, NUDOCS 9712110051
Download: ML17354A730 (6)


Text

CATEGORY 1 REGULA . Y~'INFORMATION DISTRIBUTIO YSTEM (RIDS)

A Cj aION NBR:9712110051 DOC.DATE: 97/12/04 NOTARIZED: YES DOCKET F. '~:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 05000250 F 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C 05000251 AJTH.NAME AUTHOR AFFILIATION HOVEY,R.J. Florida Power 5 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards revised TS section 6.9.1.7, "COLR," clarifying references 4 S 6 by adding best estimate LOCA to COLR &

documenting re-analysis performed as result of revs to large break LOCA methodology.

DISTRIBUTION CODE: AOOID TITLE: OR COPIES RECEIVED:LTR Submittal: General Distribution l ENCL g SIZE: +!

E NOTES:

RECIPIENT COPIES RECIPIENT COPIES 0 ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-3 LA 1 1 PD2-3 PD 1 1 CROTEAU,R 1 1 INTERNAL: LE CE 1 1 1 NRR/DE/ECGB/A 1 1 NRR DE/EMCB 1 1 NRR/DRCH/HICB 1 1 NRR/DSSA/SCSB 1 0 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 NUDOCS-ABSTRACT 1 1 OGC/HDS3 1 0 EXTERNAL: NOAC 1 1 NRC PDR 1 1 D E

N NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 14 ENCL 12

'l J

l

DEC 04 ~997 L-97-295 10 CFR $ 50.36 P&ll 10 CFR $ 50.90 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 Proposed License Amendments On February 24, 1997, Florida Power and Light Company (FPL) submitted I 97-037, "Large Break Loss of Coolant Accident Re-analysis," L-97-037 requested that Appendix A of Facility Operating Licenses DPR-31 and DPR-41 be amended to modify Turkey Point Units 3 and 4 Technical Specifications Section 6.9.1.7, Core Operating Limits Report (COLR). This requested change will add Best Estimate Large Break Loss of Coolant Accident Analysis (BELOCA) to the COLR. By letter L-97-108, FPL requested ari t onal reference b added to the Turkey Point Units 3 and 4 Technical Speclf cations Sect on 6917

'dd Core Operating Limits Report, in order to document the re-analyses performed as a result of revisions to the large break LOCA methodology.

As discussed with the NRC Staff on November 17, 1997, FPL requests the attached revisions to References 4 and 6 listed in page 6-22 of the Turkey Point Units 3 and 4 Technical Specifications Section 6.9.1.7, Core Operating Limits Report. The proposed changes provide clarification to the information previously submitted to the NRC by FPL letter I 97-037. No changes have been made to the analyses or references described in L-97-037. Therefore, the conclusion of the No Significant Hazards Evaluation remains valid.

Should there be any questions on this request, please contact us.

R.. Hovey Vice President Turkey Point Plant OIH Attachment cc: L. A. Reyes, Regional Administrator, Region II, USNRC T. P. Johnson, Senior Resident Inspector, USNRC, Turkey Point Plant W. A. Passetti, Florida Department of Health and Rehabilitative Services 97i2ii005i 97i204W PDR ADOCK 05000250 P PDR llllllllllllllllllllllllllllllllllllllll an FPL Group company

E I; ,~ t f

)l I

1-295 qktsy Point Units 3 and 4 Docket Nos. 50-250 and 50-251 Proposed License Amendments STATE OF FLORIDA )

) ss.

COUNTY OF DADE )

R. J. Hovey being first duly sworn, deposes and says:

That he is Vice President, Turkey Point Plant, for the Nuclear Division of Florida Power & Light Company, the Licensee herein; That he has executed the foregoing document; that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.

R. J. Hovey STATE OF FLORIDA A'i~-

COUNTY OF ~de Sworn to and subscribed before me this ~ day of 6t~~, 19 ~~

by R. J. Hovey, who is personally known to me,

( A--

Name of Notary Public - State of Florida CHE RYL A. STEVENSON jaf taae MYCOMMtSStONICC5640P v'; sg; EXPIAES: June19,2II