CATEGORY j.

REGULAT INFORMATION DISTRIBUTION ISTEM (RIDS)

ACCESSION NBR:9701170095 DOC.DATE: 97/01/15 NOTARIZED:

NO DOCKET I FACIL:50-244 Robert Emmet Ginn'a Nuclear Plant, Unit 1; Rochester G.

05000244 AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.

Rochester Gas 6 Electric Corp.

RECIP.NAME'ECIPIENT AFFILIATION VISSING,G.S.

SUBJECT:

Provides response to RAI 6 resubmits level 1

PSA of Ginna Station.

DISTRIBUTION CODE:

A001D COPIES RECEIVED:LTR ENCL 3 SIZE:

TITLE: OR Submittal:

General Distribution NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

gg) 05000244 RECIPIENT ID CODE/NAME PD1-1 LA VISSING,G.

INTERN

FILE NRR/DE/EMCB NRR/DSSA/SPLB NUDOCS-ABSTRACT EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD1-1 PD NRR/DE/ECGB/A NRR/DRCH/HICB NRR/DSSA/SRXB OGC/HDS3 NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

0 1

1 E

G R

Y 1

D E

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN SD-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 13 ENCL 12 1

AND ROCHESTER GASANDElECTRIC CORPORATION

~ 89 EASTAVENUE, ROCHESTER, N.Y. Id6d9-000I AREA CODE 7/6 5d6-27Ã ROBERT C. MECREDY Vice President Nvefeor Operotions January 15, 1996 U.S. Nuclear Regulatory Commission Document Control Desk Attn:

Guy S. Vissing Project Directorate I-1 Washington, D.C. 20555

Subject:

Generic Letter 88-20, Level 1 Probabilistic Safety Assessment (PSA)

Rochester Gas &Electric Corporation R.E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Mr. Vissing,

By Reference 1, RG&E submitted a Level 2 PSA in response to Generic Letter (GL) 88-20, Individual Plant lamination for Severe Accident ViIlnerabilifies. Subsequent to that submittal, RG&E identified several inconsistencies and unwarranted conservatisms within the PSA models and determined that a re-assessment of the Level 2 PSA was appropriate (Ref. 2). In the midst ofperforming this new analysis, the NRC provided RG&E with a request for additional information (RAI) related to the March 15, 1994 submittal (Ref. 3). RG&E responded to this RAIwith several letters which ultimately extended RG&Es response until January 15, 1997 (Refs. 4, 5, and 6). Therefore, the purpose ofthis letter is to provide a response to the RAI and to resubmit a Level 1 PSA ofGinna Station. In addition, an update to all outstanding responses to the remaining GL 88-20 supplements is being provided.

With respect to the RAIdocumented in Reference 3, Attachment Ato this letter contains the response to all NRC questions and comments.

The response to these questions is primarily based on Revision 1 to the Ginna Station PSA as contained in Attachment B. This document replaces the Level 1 PSA provided in Reference 1 in its entirety. The Level 2 and flooding

~

portions of the PSA willbe updated and re-submitted to the NRC in accordance with the schedule listed below.

GL 88-20 is comprised ofmultiple supplements related to severe accident vulnerabilities. A description of each supplement and RG&E's understanding of its status is provided below:

- 970i-i70095 970ii5

".PDR"'" ADOCK 05000244 PDR

@I~I.

I k

(

Generic Letter88 This requested an individual plant examination (IPE) of each plant that was basically comprised of an evaluation of core damage frequency (Level 1

PSA), containment performance (Level 2 PSA), and a flooding evaluation.

RGEcE originally responded to this request in Reference 1; however, Attachment B to this letter supersedes the previous Level 1 PSA. A new Level 2 PSA willbe submitted to the NRC by May 1, 1997 (Ref. 6). The new flooding analysis willbe presented with the rest of the external events by September 30, 1997 (see Supplement 4 below).

b.

Supplement J - This announced the availability ofNURI:G-1335 which provided reporting guidelines with respect to the IPE as discussed in a. above.

This NUREG was used in the preparation of the PSA such that no further action is required.

C.

Supplement 2 - This requested consideration ofsevere accident management (SAM) strategies in the IPE process.

Subsequent to this document, the nuclear industry developed generic SAM guidance and committed to implement SAM capabilities by December 31, 1998. RG8cE responded to the supplement in Reference 7 and stated that we would meet this deadline; however, we also identified that RGB was "actively pursuing completion ofthese tasks in 1997." Due to the delays. in completing the Level 2 PSA which provides an input into the plant-specific SAM guidelines, RGB does not expect to complete these activities in 1997. However, the industry deadline ofDecember 31, 1998 willstill be met.

Supplement 3 - This announced the completion ofthe NRC's containment performance improvement program.

Relevant information willbe incorporated into the Level 2 PSA and SAM guidelines such that no further action is required on this specific supplement.

Supplement 4 - This requested an IPE for external events (IPEEE) and provided NUREG-1407 for reporting information. The followingprovides a status of each required external event evaluation:

Seismic events - This is being addressed as part ofthe closeout ofGL 87-02, VerificationofSet'smic Adequacy ofMechanical and Electrical Equipment in Operating Reactors, Unresolved Safety Issue (USI) A-46. Afinal report on these topics willbe submitted to the NRC by February 1, 1997 (Reference 8).

Internal fires - RGEcE willsubmit a fire analysis by September 30, 1997 (Ref. 9).

Per Reference 10, RGB'lans to use the guidance ofNUI&G-1407, Section 14.1 and the EPRI FIVE propagation and damage assessment models for screening purposes, and the FIVEwalkdown procedures to address Fire Risk Scoping Study (FRSS) issues.

High winds and tornadoes - In Reference 11, RG&E stated Ginna Station was designed to withstand a 1E-05/yr tornado with structures capable ofwithstanding a 1E-06/yr tornado.

This was considered to meet Section 5.2.4 ofNUREG-1407.

The NRC responded in Reference 12 that since RG&E was using "the screening approach described in NUREG-1407 for high winds...", this was acceptable.

Consequently, RG&E considers this external evaluation complete.

External floods - In Reference 11, RG&E stated that a Probable Maximum Flood with a recurrence interval of 5E-04/yr was used as the basis for the Systematic Evaluation Program (SEP) of Ginna Station.

Necessary plant modifications were implemented to meet this flooding event such that Section 5.3 ofNUREG-1407 was considered to have been met. The NRC responded in Reference 12 that since RG&E was using "the screening approach described in NUREG-1407 for high winds, floods...", this was acceptable.

Consequently, RG&E considers this external event evaluation complete.

Transportation and nearby facility accidents - In Reference 11, RG&E stated that the NRC safety evaluation for SEP Topic II-1.C concluded that the Standard Review Plan was met for these issues.

Therefore, RG&E considered that Section 5.2.3 ofNUREG-1407 was met. The NRC responded in Reference 12 that since RG&E was using "the screening approach described in NUREG-1407 for high winds, floods, and transportation and nearby facility accidents," this was acceptable.

Consequently, RG&E considers this external event evaluation complete.

Supplement 5 - This announced that seismic review requirements as outlined in NUREG-1407 could be downgraded'based on NRC re-assessment ofpotential seismic events.

RG&E responded in Reference 13 that RG&E had already downgraded our seismic reviews from those in NUI&G-1407. The seismic evaluation willbe provided by February 1, 1997 as described in e.1 above.

In addition to GL 88-20 and its supplements, the NRC requested that RG&E specifically evaluate two other issues in the PSA as follows:

During the Safety System Functional Inspection ofthe Residual Heat Removal system in 1989, the NRC identified a potential scenario where the discharge line for Service Water cooling to the diesel generators could crimp during a during a design basis seismic event (Ref. 14). RG&E responded to this beyond design basis concern by agreeing to evaluate the scenario in the PSA (Ref. 15). This evaluation is provided in Section 9.4.1 of Attachment B to this letter.

b.

In Reference 16, the NRC identified a potential concern related to hydrogen storage adjacent to the diesel generator buildings and requested that RG&E evaluate this issue as part of Supplement 4 to GL 88-20. This evaluation willbe provided by September 30, 1997 consistent with the discussion above.

Please contact George Wrobel, Manager ofNuclear Safety and Licensing at (716) 724-8070 if you have further questions.

Ver ly yours, Robert C. Mecredy

References:

Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC, Generic Letter 88-20, dated March 15, 1994.

2.

Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC,'Level 2 Probabilistic Risk Assessment, dated March 10, 1995.

Letter from A.R. Johnson, NRC, to R.C. Mecredy, RG&E, Ginna Probabilistic Risk Assessment Project Report ofMarch 15, 1994, to the NRCin Response to Generic Letter 88-20; Request forAdditional Information (TACNo. M74414), dated February 23, 1995.

4 Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC, Generic Letter 88-20, Response to Request forAdditional Information (TACNo. M74414), dated April 19, 1996.

5.

Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC, Generic Letter 88-20, Updated Response to Request forAdditional Information (TACNo. M74414), dated July 31, 1996.

6.

Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC, Generic Letter 88-20, Updated Response to Request forAdditionalInformation (TACNo. M74414), dated November 15, 1996.

7.

Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC, Severe Accident Management, dated March 24, 1995.

8.

Letter from R.C. Mecredy, RG&E, to G.S. Vissing, NRC, Generic Letter 87-02, Supplement 1 (TACNo. M69449) and Generic Letter 88-20, Supplement 4 (TACNo.

M83624), dated November 15, 1996.

Letter from R.C. Mecredy, RG&E, to G.S. Vissing, NRC, Generic Letter 87-02, Supplement 1 (TACNo. M69449) and Generic Letter 88-20, Supplement 4 (TACNo.

M83624), dated August 26, 1996.

10.

Letter from R.C. Mecredy, RG&E, to A.R. Johnson, NRC,'Individual Plant Examination ofI<<<eternal Events (IPI<I<I<), 180 Day Response to Generic Letter 88-20, Supplement 4, dated December 26, 1991.

Letter from R.C. Mecredy, RGB', to A.R. Johnson, NRC, IndividualPlant Examinations forE<xternal Events (IP~<<<), dated November 3, 1992.

12.

Letter from A.R. Johnson, NRC, to R.C. Mecredy, RGEcE, RE. Ginna - Review of Response to Generic Letter 88-20, Supplement 4 - IndividualPlant Examinations for External Events (TACNo. M83624), dated August 11, 1993.

13.

Letter from R C. Mecredy, RG8cE, to G.S. Vissing, NRC, Response to Generic Letter 88-20, Supplement 5, dated November 7, 1995.

14.

Letter from M.W. Hodges, NRC, to R.C. Mecredy, RG&E, NRC Safety System Functional Inspection Tea)n Report No. 50-244/89-81, dated May 9, 1990.

15.

Letter from R.C. Mecredy, RG&E, to T.T. Martin, NRC, Response to Inspection Report 50-244/89-81, Safety System Functional Inspection -RHR System, dated June 8, 1990.

16.

Letter from A.R. Johnson, NRC, to R.C. Mecredy, Risk Associated 5'ith Hydrogen Storage Facility at Ginna, June 24, 1993.

Attachments MDF7897 xc:

U.S. Nuclear Regulatory Commission Mr. Guy S. Vissing (Mail Stop 14C7)

PWR Project Directorate I-1 Washington, D.C. 20555 U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King ofPrussia, PA 19406 Ginna Senior Resident Inspector

~

~

Attachment A Response to February 23, 1996 RAI

'9701170095

Rcsponsc to February 23, 1996 RAI The following pages provide a response to the questions documented in the February 23, 1996 request for additional information (RAI) letter froni A.R. Johnson, NRC, to R.C. Mecredy, RGAE. This RAIwas provided with respect to the Ginna Station Level 2 PSA submitted by RGRE on March 15, 1994. However, the Level 1 PSA has been revised and is being resubmitted to the NRC as part ofthis letter (see Attachment B). In addition, the Level 2 PSA willbe revised and resubmitted by May 1, 1997. Therefore, the NRC questions and comments do not match up with the new page numbers and sections, and in some cases, may no longer be applicable.

As such, RGBs response to the RAI consists ofthe following:

The NRC question is repeated (in italics) followed by a RGRE response.

For the Level 1 PSA and human error questions (RAIEnclosure 1 and 2, respectively),

the RGkE response consists of a reference to a specific section within the revised Level 1 PSA which addresses the subject.

The revised Level 1 PSA was specifically written to include relevant discussion ofthose topics which the NRC raised'issue with in the February 23, 1996 RAI. The only exception to this is with respect to flooding (see Enclosure 1 Question 10 and Enclosure 2 Question 14) which willbe provided by September 30, 1997 when the external event PSA is submitted.

For the Level 2 PSA questions (RAIEnclosure 3), the RGEcE response is with respect to the March 15, 1994 submittal only. This response indicates whether RGB plans to make a change to the approach used in the new Level 2 PSA or continue to use the original technique.

The results ofusing any new approach willbe provided when the revised Level 2 PSA is submitted to the NRC (see response to Enclosure 3 Questions 5, 6, 7, 9, 10, and 17, and Enclosure 2 Question 15).

Rcsponsc to February 23, 1996 RAI ENCLOSURE 1

LEVELI QUESTIONS The followingquestion concerns the Bayesian updating scheme used in the individual plant exainination (IPI'):

In the modeling ofloss ofoffsitepower (LOOP) events, your Bayesian updating scheme leads to an order ofmagnitude reduction in the LOOPfrequency over the generic nuclear power plant LOOPfrequency.

The total LOOPfrequency calculatedis about 3.5I 3lyr. Considering the relativelyjequent weather phenomena (e.g., ice storms) in the Ginna area that could conceivably lead to a loss ofthe whole grid, this number seeins very low.

Itis also surprising that Bayesian updating could lead to such a large reduction in theinitiating event frequency.

The discussionin the submittalindicates that you are attempting to update a prior distribution with evidence ofzero failures in 9 years.

Please note that such evidence is not very strong since the prior mean of occurrence rat'e is 0.0271yr, or one failure in about 50years.

1~or cases ofweak evidence, the prior distribution should dominate the behavior ofthe posterior distribution. However, thisis not the case for the application results presentedin the submittal.

Itwould appear that you have replaced the Lognormal prior with an equivalent Gamma prior, which is conj ugated with a Poisson likelihood under the 13ayes algorithm.

The method usedfor translating Lognormal to Gamma is the method ofmatching the first two moments (mean and variance).

However, the Gamma distribution is not a good approximation fora Lognormal distribution when the resulting parameters ofthe Gamma distribution (namely a and p)fallin certain regions, specifically, ifthe parameter u becomes less t'han or equal to one. In such a case, 1he Ganmia distribution would not have any >naximuni, and ifused as a prior would heavily weight the low values ofthe occurrence ra1e, contrary to the Lognormal distribution.

This appears to be the case foryour application. It is also iinportant to note that the parameter u is uni tless and would not change if an annual occurrence rate or a 100-year occurrence rate is used (in contrast, the p parameter has dimensions oftime).

Use ofthe Ganima distribution is not reconmiended for cases in which the parameter ufalls below one. Inpractice, the Gainma distribution should only be used as an approximation to the Lognormal distribution when u is greater than two. Calculations show that ifa Lognormal distributioninstead ofa Ganmia distributionis used, yourprior mean of0.027lyr and errorfactor of23. 7 result in a posterior mean of0. 015lyr and an errorfactor of8.5, a much more modest reduction than that indicatedin the 0

Response to l cbruary 23, 1996 RAI submittal.

For these reasons, and the fact that the updating was done with the relatively weak evidence ofnofailure in riyears, the posterior distribution obtained appears to be in error.

Please recalculate your Bayesian update using a Lognormal prior distribution and compare the resiilts ivithyour submittal. Please provide the impact this adjustment in modeling has on the core damage pequency (CD&)and on the important seqiiences.

See Section 7.3.1.2.

The new loss ofoffsite power frequency is 6.32E-02/ryr.

(b)

Please explain your Bayesian updating treatment ofreliabilitydata for other coniponents where conditions similar to the ones foundin LOOP treatment existed (i.e., u<land sparse or zero plant-specific evidence). For example, the followingcomponent failure rates mayfallinto this category: 120-volt ac bus failures, auxiliaryfeedwater (AF0) and residual heat removal puinpfailure rates, and safety injection and service water (SN) demandfaiiure rates.

Please discuss how the Bayesian updating ofthese coinponents was done (e.g., how nianyfailures were experienced, details ofBayesian updating calculations, and the finalposterior numbers usedin the IPE).

Ifan adjustment infailure data is necessary, please provide an estimate ofthe impact on the CDF andimportant sequences.

Appendix C contains a detailed discussion of the plant-specific data collection effort. Table C-3 provides a listing of the failure data used in the PSA models for which plant-specific data was collected against.

The table provides plant-specific failure data ("Plant"), generic data ("Aggregated" ), and final value used in the PSA ("I'inal"). Essentially, ifno component failures were observed in a given population, generic data was used. Ifone or two component failures were observed, Bayesian updating was typically performed. Ifa significant number of failures were observed (i.e., more than two), only plant-specific data was used.

2.

Thefollowingquestion concerns the modeling ofLOOP events:

(a)

Itis not clear how the possibi lityofa post-trip LOOP was modeled.

The submittal states that i'e conservative assumption is made in i'hat a reactor trip would lead to a LOOP as a result ofa grid transient caused by a-loss ofthe Gimia generating capacity.

Does that incan that any initiator (e.g., a loss-of-coolant accident (LOCA), a transient) willalso lead to a LOOP and a demand for

/

Response to February 23, 1996 RAI diesel generators? In that case, a loss ofS8'would leadfirst to a LOOP, and then to a station blackout (SBO), because SN'is used to cool the diesels.

Therefore, a loss ofSP'initiator should have a relatively high conditional core damage probability, which is not supported by the results.

Please clarify the treatment of the post-initiator LOOP and provide data (and the bases) for the conditional probability ofa LOOPfollowinga reactor trip. Ifan adj ustment in modeling is necessary, please provide the impact on the CDF results and the important core damage sequences.

Section 3.4.2.3 discusses the post-trip LOOP event while Section 7.3.1.2 discusses the data used for these events.

In summary, a post-trip LOOP was considered for any initiator (similar to UFSAR Chapter 15 assumptions) since the loss of Ginna Station ~uld lead to sufficient grid instability so as to result in a subsequent LOOP.

There is no discussion ofLOOP and SBO sequences, and no separate event tree is provided, even though a statement is made that these events are treated separatelyPom other transients because oftheir special nature.

Please discuss exactly how you treated SBO and provide the SBO event tree, ifavailable.

A SBO event tree has been generated as shown in Section 5.2. AllSBO scenarios are transferred to the SBO event tree for evaluation.

The only exceptions are for medium and large LOCAs and ATWS events which are assumed to directly result in core damage.

Itis not clear how the turbine-driven auxiliaryfeedwater (TDAFS) pump is used under SBO conditions and how itis modeled.

The dependencies ofthis pmnp include SS'; heating, ventilation, and air conditioning (HVAC); and dc voltage.

Itis stated that a test run ofI hour and 45 nunutes was made to show that the pinup can survive a total loss ofac power (i.e., loss ofS8'cooling to the bearing oil coolers).

However, no test was run beyond that time.

Another test showed that the temperatures willreach l45'F in the TDA1<5'room after a 4-hour loss ofHVAC. There is no indication as to what happens beyond the 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, except for a statement that there would be no damage foral least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, but thatfor conservation a l0-hourpower recovery is modeled.

There is no indication ofthe depletion timefor the battery supporting TDAb"5'peration (other than the 1,200 amp-hr capacity gi ven), ofhow this conclusion was <<iodeled, or what battery supports TDAF8'operation(e.g., isit battery IB?).

The TDAF0'pumps are tested to show operation over a 2-hour period.

4

Response to February 23, 1996 RAI Please describe the sequence ofevents for SBO in a nianner siinilar to thatfor other initiators, which specifically addi'esses the operation and modeling (including the time assumed for operation) ofthe TDAP"5'pump.

The success criteria used for the SBO event tree (and TDAFWpump) is found in Section 4.2.2.4, ~r~lin, and Appendix B.

Certain details are not clear about the design and operation ofthe 125V-dc systeni.

Can the technical support center (TSC) battery support the operation of the safeguards equipment in an SBO ifbattery 1A or IBfailed, and how is this eventuality modeled? Can the IA or 1B battery support the operation ofthe other division and howis thisfimction modeled? 5'hy is the TSC battery the only one tested (apparently) and tested onlyfor 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />? Is thisperiod the assumed running time ofthe. TDA1$'pump in an SBO? 8%at are the depletion timesfor the 1A, IB, and TSC batteries?

The TSC battery has the capability to tie into DC safeguards trains as shown in Figure 6-8. However, due to the significant amount ofeffort required to utilize this capability, credit was not assumed in the PSA (or in the SBO mitigation plans per 10 CFR 50.63). With respect to cross-support among Battery A and B, there is the capability for certain loads on a DC train to be supplied by the opposite train during emergency conditions (e.g., diesel generator support).

This is an automatic feature incorporated into the PSA.

Itis stated that the TSC battery andlor the standby electric power TSC diesel(s) can be used as a limited backup should the main emergency diesel generators (I"'DGs)fail. 8%ich loads can these diesels support? Please explainifthese diesels are credi ted in the model, and ifso, explain how they were modeled (including operator actions, unavailability, andfailrire data).

Credit for the TSC diesel generator was not assumed in the PSA model.

Itseems that the hardware exists for cross-connecting the eniergency buses.

Is this action proceduralized Ifso, is credit taken foritin the IPL<", and how wasit modeled?

The capability for cross-connecting the 480 V safeguards buses exists within the emergency plans. However, this action was not deemed critical for the PSA, and as such, was not credited.

Please explain why the events ofJanuary21, 1985 (LER 85-002), aird July 16, 1988-(LLR 88-006), were not counted as plant-specific LOOP events in the

Rcsponsc to Pcbruory 23, 1/96 RAI Bayesian updating calculation ofLOOPfiequency.

The former event was an incipient LOOP, in which both EDGs were started and tied to their safeguards buses oflowgridfrequency caused by extremely cold weather.

The latter event was via loss ofnormal power, includingpower to allfour safeguards buses, such that both EDGs were started and loaded onto the safeguards buses.

See Sections 3.3.4 and 3.3.9 for discussion ofthese events.

The EDGfideloil (ransfer system is apparently modeled separately from the L<DGs. However, the Common Cause Tables (3.3.4-I and 3.3.4-2) do not seem to show these pumps, even though there has been at least one event involvinga common cause failure ofthese pumps.

The event ofE~'ebruary 20, 1987 (LER 87-001), involvedplugging ofthe strainersin both puInps as a result ofthe use ofthe inappropriate materials to clean the fuel oiltank Please explain how this event wasincorporatedin the modeling ofthe common-cause failure ofthe EDGfuel transfer system. Ifthe event was not accounted for, pleasejustify the omission.

CCFs of the diesel fuel oil pumps has been added to the model (see Table 7-3).

3.

This question concerns the treatment ofthe main feedwater (MF8) sys(em:

(a)

Please provide a description ofthe A8<8'system and howit was modeled (e.g.,

which components were taken into account?).

See Section 6.14.

(b)

A statement is made that the Ml0'pumps cannot be used below 4 percent power.

The power level willfallbelow this value very quickly after shutdown, yet M/~

5'peration seems to be creditedin many sequences, and there is no discussion of any timing concerns with respect to the MFK Please clarifyhow and when MFV'pera(ion was creditedin the analysis. Ifan adj ustment in the Inodeling of MF8'is necessary, please provide an estimate ofthe impact on the results and on the important sequences.

See Section 6.14 for discussions ofhow MFW was credited. Note that the MFW system ~cn be used below 4% power (and is typically used initiallypost-trip).

However, due to the difficulties in maintaining SG levels under these low power conditions, the motor-driven AFW pumps are normally used during startup and planned shutdown activities. These difficulties do not prevent use of the MFW system during accident conditions as instructed by the EOPs.

"4 Please provide the bases for using the cutset truncation limitofS.I" 8lyr, which is

Response to February 23, 1996 RAI relatively high compared to industry practice, and provide an estimate ofthe residual. If the residual is sigvificant (e.g., greater than 5 percent ofthe CDF), please pr ovide an estimate ofthe impact on the important sequences and on the results.

A new truncation limitof 1.0E-10 was used as discussed in Section 9.3.1.9.

One ofthe small-small LOCA success paths utilizes a rapid cooldown ofthe reactor coolant system (RCS) to lowpressure injection (LPI) conditions.

Thisprocessis supported by modular accident analysis program runs, according to the submittal. Are there procedures inplace to utilize this options Ifnot, provide the bases for crediting this action. Ifavailable, please provide an estimate ofthe impact on the results and important sequencesif this option was not credited.

P P

.,,~ll-II CAPP CI*Pf Ch I

ff operator action.

6.

This question concerns the treatment ofinitiating events:

(a)

The sinall-small LOCAinitiating event jequency in the Ginna IPI7 is significantly smaller than that used in NU1KGICR-4550.

The IPL~"S3 frequency is 7.3L-4 versus the NURK<GICR-4550frequency-of 1.3E-2. Itdoes not seem to include such events as spurious reactor coolant pump (RCP) seal LOCAS, which are a major contributor to the S3 frequency in NU1K~GICR-4550 and other studies.

Please provide the bases for excluding RCP seal LOCAsPom the S3 frequency and, ifavailable, provide an estimate ofthe impact on the results and the important sequences ifa more traditional small-small LOCAfrequency estimate ls used.

Spurious RCP seal LOCAs have been included within the small-small LOCA frequency as discussed in Section 7.3.1.6. The total frequency ofsmall LOCAs due to pipe breaks and spurious RCP seal LOCAs is now 6.6E-03 (note that Ginna Station only has two RCPs).

(b)

Please explain why the loss ofa 4kV-bus is not considered as an initiating event.

For example, loss ofbus 12A or 128 might cause an initiating event whilefailing safeguards equipment on that bus.

See Sections 3.3.4 and 3.3.9.

(c)

At least two events at Ginna have involved the possibility ofPeezing, leading to a loss ofSK This situation could be due tofrazilice buildup on the intake screens.

Rcsponsc to February 23, 1996 RAI In addition to the event discussed in the IPL~ (LER 83-006) caused by lowering of the voltage to the intake heaters, a Inore recent event occurred after the IPL<"

submittal.

This event involved a zebra mussel buildup on the heaters, again causing frazilice buildup.

In calculating the frequency ofthe loss ofSS'initiator in the IPL, was the possibility ofice buildup accounted for? Ifso, please sunrmarize howit was taken into consideration. Ifit was not, please provide an estimate ofthe impact on the CDF and on important sequences.

See Section 7.3.1.8 for a discussion ofthe frequency for loss of SW.

(d)

Extremely cold weather could conceivably cause a LOOP because ofa high load on the grid (a precursor event occurred in January 1985; see question 2 (gJ above), in conjunction with a loss ofSS'because ofice buildup as discussed in part (c). Loss ofSS'would, in turn, lead tofailure ofthe diesel generators, 1hus leading 1o an SBO. Please discuss howyou considered such an initiating event.

Ifthis event has not been adequately considered, please provide an estimate ofthe impact ofthis event on the CDF and on important sequences.

The frequency ofLOOP was based on industry data between 1980 and 1995 such that extremely cold weather is a consideration.

A coincident failure of SW is considered very unlikely due to the fact that frazil ice occurs followingrapid changes in wind direction (i.e., from the north). Therefore, the extreme temperatures would have to be followed by a rapid wind change, with a subsequent failure ofall RG8.'E preventative measures.

(e)

Please provide the frequency estimate usedforinitiation ofan anticipated transient without scram (AT0'S) in the IPE~ analysis.

See Section 7.3.1.11.

7.

This question concerns the data usedin the model:

(a)

In discussing components with relatively highfailure rates compared to generic data (e.g., containment spray pumps), a statement is made that the high rate of failure is due 1o a limitedtest exposure time, and not necessarily t'o a plant vulnerability. However, certain failure modes (e.g., sediment buildup) may appear in components that are idlefor long periods.

Please verify that the plant experience for these components with a relati vely high failure rate was retainedin developing the database.

Rcsponsc to February 23, 1996 RAI See Section 7.2.1.3.1 and Appendix C.

(b)

Please provide the finalreliabilitydata listings ofAppendix L. Ifnotincluded already in Appendix I, please also provide the generic data used, as wellas the plant-specific experience (e.g., number ofdemands, or number ofhours, and number offailures) for each failure mode and each coinponent.

See Tables 7-1 and Appendix C, Table C-3.

(c)

The coinmon-cause analysis seems to have oinitted some potentially important components, which might influence your search for vulnerabilities.

The following components were apparently not considered:

'I Circuit breakers Relays (engineered safety features actuation system)

Electrical switchgear Transmitters Ventilationfans Aircompressors Inverters In addi tion, conmion-cause failures within the AF0'and standby auxiliary feedwater (SAI<"5) systems, also involving the turbine driven pump (i.e., driver independent failures), coiildbe postulated Please provide the bases for oinitling these potential conrmon-cause failures and discuss howyou ensured that no vulnerabilities were mused as a result ofthese omissions.

See Section 7.2.2 and Table 7-3 for detailed discussions related to common cause failures.

(d)

Please show how the possibility offreezing, along with any plant specific data involvingfreezing, has been accounted forinfailure data and common-cause failure data for components that are viilnerable to thisphenomenon.

Apparently, this phenomenon includes the SAFE'systeni, the EDGs, and the SW system.

See Sections 3.3.5 and 6.11.

8.

It is not clear from the submittalifplant changes as a resiilt ofthe SBO were creditedin i

the analysis.

Please provide the followinginformation:

Rcsponsc to February 23, 1996 RAI (a)

Discuss whether plant changes (e.g., procedures for load shedding, ac power) made in response to the SBO were credited in the IPE and which plant-specific plant was credited.

The Ginna Station design with respect to meeting 10CFR50.63 was used in the-Ginna Station PSA.

(b); Ifavailable, provide the total impact ofthese plant changes to the total plant CDF and to the CDF contribution from SBO (i.e., the reduction in total plant CDF and SBO CDF).

Since the revised PSA began with the current Ginna Station design (i.e., post implementation of any SBO related plant changes) no

~ can be provided.

(c)

Ifavailable, provide the impact of each individual plant change on the total plant CDF and the SBO CDF (i.e., the reduction in total plant CDF and SBO CDF).

Since the revised PSA began with the current Ginna Station design (i.e.; post implementation of any SBO related plant changes) no

~ can be provided without significant modeling changes.

(d) 'iscuss any other changes to the plant that are separate from those made strictly in response to the SBO rule that nonetheless may reduce the SBO CDF. In addition:

(i)

Describe whether these changes are implemented or planned.

(ii)

Indicate whether credit was taken for these changes in the IPE.

(iii)

Ifavailable, discuss the impact ofthese changes on the SBO CDF.

Allplant changes made as a result of the Ginna Station PSA are discussed in Section 11.1.2.

This question concerns the treatment ofHVACfailures, either as an initiating event or subsequent to an initiator. A description ofthe HVACsystem is provided in Section 3.2.l.8, along with success criteria and a description ofoperation under normal and accident conditions.

- Itis stated in the submittal that loss ofcontrol building ventilation willnot lead to an initiator because operator inspections are perfornied on a regular basis.

There is no discussion about other HVACareas causing an initiating event.

Please provide a more complete description ofyour investigation into the impact of loss ofHVACto the rooms containing safety-related equipment.

Discuss the equipment e

1<esponsc to February 23, 1996 RAI sensitive to temperature change, where that equipment is located, methods of assessment (e.g., calculations or tests to determine the temperatures and timing), and credits for operator actions and timing.

Give this informationfor temporary equipment, as weII. Please provide the rationale for elimination ofloss ofHVACas an initiating event or as support to specific equipment.

Consider, the fact that equipment may be tripped on high temperature before the damage threshold is reached.

See Sections 3.3.5 and 11.1.1.

10.

The following question concerns the treatment offlooding:

(a)

Please discuss your consideration ofdrains (including back flooding to other areas and the probability offailure, i.e., due to blockage) and ofdoors allowing flooding ofother areas.

As theflre zones are used for delineation offlood zones, discuss whether allflre doors are waterproof at Ginna and whether failure of these doors to be in a closed position is accounted forin the model.

A response willbe provided by September 30, 1997 following re-analysis of the flooding PSA..

(b)

Please discuss whether inadvertent actuation oftheflre suppression equipment (i.e., notjust pipe failures in this system) is accounted forin the analysis and estimate its impact on the flooding scenario results ifit'is not.

A response willbe provided by September 30, 1997 following re-analysis of the flooding PSA.

(c)

Please discuss the operator actions needed forisolation and mitigation ofthe most important flood scenarios and provide the basis forflood-affected human error probabilities (HEPs) used. (It seems the same HEPs as in the internal events analysis were used for some actions, disregarding the additional stress that would be placed on the operator.) Discussion ofany alarms or any other means the operators would use to detect and stop the flood.

A response willbe provided by September 30, 1997 following re-analysis of the flooding PSA.

(d)

Discuss how maintenance errors were treated in the flooding analysis.

Include errors committed while in cold shutdown that were left undiagnosed until the flood event occurred while the unit was at power.

A response willbe provided by September 30, 1997 following re-analysis of

Rcsponsc lo February 23, 1996 RAI the flooding PSA.

11.

From the description ofthe system, "Primary Pressure Control System, "itis not clear how the pressurizer power-operated reliefvalves (PORVS) and the block valves are modeled.

Please provide the followinginformation:

(a)

Whatfraction oftime are the block valves closed?

See Appendix C, Table C-4 (events RCMVD00515and RCMVD00516).

(b)

How are closed block valves accounted forin the model (for example, in modeling ATWS, feed and bleed, and in modeling RCS integrity after transient)?

What is the estimated impact on CDF and important sequences ifblock valve operation is not considered?

The potential for the block valves being closed's specifically addressed within the models for any event in which automatic or manual operation of the PORVs is required.

Only for cases where manual opening of the PORVs is credited are the operators allowed to open a closed block valve (i.e., a closed block valve fails automatic actuation of the PORVs).

(c)

Discuss the operator actions required to open the block valves and the PORVs when needed.

Operator action to open the PORVs is addressed within various operator actions described in Appendix F, Table F-4 (e.g., RCHFD01BAF, RCHFDCDDPR).

12.

The status ofsome ofthe potential plant improvements to reduce the likelihood ofcore damage andlor improve containment performance discussed in the submittal is not clear.

Please clarif the submittal information by providing the following:

(a)

The specific improvements that have been implemented, are being planned, or are under evaluation.

See Section 11.1.2.

(b)

The status of each improvement, that is, whether the improvement has actually been implemented, is planned (with scheduled implementation date), or is being evaluated.

II

Rcsj)011sc io Fcbn)ary 23, 1996 RAI See Section 11.1.2.

(c)

The improvements that were credited (ifany) in the reported CDF.

See Section 11.1.2.

(d)

Ifavailable, the reduction to the CDF or the conditionaL containment failure

. probability that would be realized from each plant improvement ifthe improvement was to be credited in the reported CDF (or containment faiLure probability), or the increase in the CDF (or conditional containment failure probability) ifthe credited improvement was to be removed froni the reported CDF (or containment failure probability).

See Section 11.1.2.

(e)

The basis for each improvement, that is, whether it addressed a vulnerability, was otherwise identifiedfrom the IPE review, was developed as part ofother NRC rulemaking, such as the SBO rule, and so on.

See Sections 11.1.2 and 11.1.3.

13.

NUREG-1335, Section 2.1.6, Part 4, requests "a thorough discussion ofthe evaluation ofthe decay heat removal function. " Section 3.4.5 ofthe IPE, Decay Heat Removal (DHR) Evaluation, does not provide specifics and insights on vulnerabilities ofDHR systems.

Please discuss insights derived forDHR and its constituent systems and provide the contribution ofDHR and its constituent systems (includingfeed and bleed) to CDF and the relative impact ofloss ofsupport systenis on the frontline systems that perform that function.

See Section 9.2.

14.

In many probabilistic risk assessments, RCP seal LOCA is a significant contributor to the CDF either as an initiating event or as a system failure consequential to another initiator. Although the submittal discusses RCP seal LOCA, please provide the following additional information:

(a)

A discussion ofthe RCP seal LOCA niodel used.

Include the probability versus leakage rate versus time data and any specific test results.

See Section 4.2.2.3.2.

(b)

A discussion ofoperator actions that are proceduralized and their timing in the I,1 0

Response to February 23, 1996 RAt event ofa loss ofone or the other method (or both) ofseal cooling.

See Appendix F, Table F-4 (events CCHFDCCWAB, CCHFDSTART, CVHFDPMPST, and RCHFDOORCP).

15.

NUREG-l335 requests that the followinginformation be included for important accident sequences:

"a List ofmajor contributors to those accident sequences selected using the screening criteria. Major contributions such as those fromfront-line systems orfuiictions and support states, as well as contributions from unusually poor containment performance, are important forinclusion. "

The IPE submittal provides a table ofimportant sequences, as well as their description.

Please discuss ofimportant contributors (e.g., 'failure ofoperator to switch over to recirculation", or "common-cause failure ofthe residuaL heat removal (RHR) pumps")

to the failure offunctions in dominant sequences.

See Sections 9.1.1 and 9.3.2.

g f q cy p

(

-2 per steam generator would be expected),

even though the event on the B generator was included as part ofBayesian updating.

Please provide the bases for the SGTR initiating event frequency used.

l6.

This question concerns the modeling ofsteam generator tube rupture (SGTR) events:

(a)

The SGTR initiatin event re uen is somewhat smaller than ex ected 1.E See Sections 3.3.6 and 7.3.1.7.

(b)

The results indicate a relatively high contribution from SGTR events, thus implying that relatively high operator failure rates were used for this event.

Yetit seems that in light ofthe SGTR event that did occur at the plant, operator training and procedures would emphasize this kind ofevent.

Please discuss how the HEPs for this event were derived.

See Appendix F, Table F-4 (events MSHFDISOLR, RCHFDCDDPR, RCHFDCDOVR, RCHFDTR2, and RCHFDCOOLD).

(c)

Ifany adjustments in the initiating event frequency or post-initiator modeling are necessary in order to reflect the "as-built, as-operated plant, 'lease provide an estimate ofthe impact on the CDF and the dominant sequences.

Section 4.2.2.3.3~1/. discusses the success criteria for a SGTR, Section 5.7 describes the SGTR event tree, and Section 7.3. 1;7 discusses the SGTR Rcsponsc to February 23, 1996 RAI frequency determination.

No changes to these sections are required.

17.

The pressurizer safety valves might be challenged when certain transient initiators (J.OOP, loss ofinstrument air) occur because the PORVs depend on instrument air.

(a)

Please provide the conditional probabilities ofPORV challenges for various classes oftransients, particularly the ones leading to a loss ofinstrument air.

Please provide the bases for the numbers used.

See Section 4.2.2.3.1 for a description of the events which challenge the PORYs and Section 6.15 for a description of the PORVs as used'n the models.

(b)

Please provide the conditional probability used for the safety valves sticking open once challenged in scenarios under (a). above, along with the bases for the numbers used.

See Table 7-1, events RY Q, RY T, RZ Q, and RZ T.

Rcspollsc to February 23, 1996 RAI ENCLOSURE 2 HUMANRELIABILITYANALYSISQUESTIONS PRE-INITIATORHUMANERRORS The submittal is not completely clear on the organizations that participated in the human reliability analysis (HRA) portion ofthe analysis.

Please clarify the extent to which the HRA was performed by the licensee's stag versus contractors and which contractors were involved. Also, please describe any independent peer review performed for the HRA and indicate the extent to which HRA experts were involved in the, review.

See Sections 11.3 and 11.4.

The submittal does not clearly discuss the process that was used to identify and select pre-initiator human failure events (HFEs) involving miscalibration ofinstrumentation.

The process used to identify and select these types ofhuman events may include the review ofprocedures, and discussions with appropriate plant personneL on interpretation and implementation ofthe plant's calibration procedures.'lease describe the process used to identify human events involving miscalibration ofinstrumentation.

Please provide examples illustrating this process.

See Section 7.4.1 and Appendix F, Table F-3. It should be noted that miscalibration issues are typically addressed within the failure data for transmitters, indicators, etc-(see "fails low," "fails high," and "fails to respond" in Table 7-1).

The submittal does not clearly discuss the process used to identify and select pre-initiator HFEs involving the failure to properly restore to service after test or maintenance.

This process used to identify and select these types ofhuman events may include the review ofmaintenance and test procedures, and discussions with appropriate plant personnel on the interpretation and implementation ofthe plant's test and maintenance procedures.

Please describe the process that was used to identify human events involvingfailure to restore to service after test or maintenance, and examples illustrating this process.

See Section 7.4.1 and Appendix F, Table F-3.

The submittal is unclear on details ofthe quantitative screening approach used for HFEs involving restoration of equipment and instrument miscalibration. In Section 3.3.3, on page 3.3.3-1, the submittal notes that alL HFEs were initiallyquantified with screening values.

A review ofTable 3.3.3-4 indicates that all pre-initiators had a hwnan error probability (HEP) of0.003. However, a discussion ofthe basis for this value is not provided. 'lease provide the rationale for the choice ofthe screening value

Rest) onsc to February 23, 1996 RAI and discuss whether any additional analyses ofpre-initiators were conducted.

In addition, provide the rationale for how the selected screening value did not eliminate (or truncate) important human events.

Finally, ifTable 3.3.3-4 does not present all the pre-initiators modeled, please provide a List of events that were screened.

See Section 7.4.1 and Appendix F, Table F-3.

IfTable 3.3.3-4 presents all the pre-initiator events modeled, itis not clear why are there no events representing miscalibration oflevel transmitters.

Such events are usually modeled in probabilistic risk assessments ofnuclear power plants and in some cases are found to be important.

Please provide a discussion ofwhy these events were not modeled in the R.E. Ginna Individual Plant Examination (IPE).

See Section 7.4.1 and Appendix F, Table F-3.

As discussed earlier, miscalibration issues are typically addressed within the failure data for transmitters, indicators, etc (see "fails low," "fails high," and "fails to respond" in Table 7-1).

The submittal is unclear on how dependencies associated withpre-initiator human errors (restoration faults and instrument miscalibrations) were addressed and treated.

There are several ways dependencies can be treated.

In.the first example, the probability ofthe subsequent human events is influenced by the probability ofthe first event. For example, in the restoration ofseveral valves, a bolt must be "tightened. " Itisjudged that ifthe operator fails to "tighten" the bolt on the first valve, he willsubsequently fail on the remaining valves.

In this example, subsequent HEPS in the model (i.e., representing the second valve) willbe adjusted to reflect this dependence.

In the second exan>pie, poor lighting can result in increasing the likelihood ofunrelated human events; that is, the poor lighting condition can affect the abilities ofdifferent operators'o properly calibrate or to properly restore a component to service, although these events are governed by different procedures and perfor'med by different personnel.

This type ofdependency is typically incorporated in the HRA model by "grouping" the components so that they fail simultaneously.

In the third example, pressure sensors x and y may be calibrated using different procedures.

However, ifthe procedures are poorly written such that miscalibration is likely on both sensors x and y, then each individual HEP in the model representing calibration ofthe pressure sensors can be adjusted individually to reflect the quality ofthe procedures.

Please provide the followinginformation concerning the treatntent ofpre-initiator dependencies:

(a)

A concise discussion ofhow dependencies (and human action common cause factors, where appropriate) were addressed and treated in the pre-initiator HRA.

Dependencies were not specifically addressed within pre-initiator human errors.

As described in Appendix F, Table F-3, the available indication to 0

Rcsponsc to Fcbntary 23, 1996 RAI operators of the status of instrumentation and major equipment eliminates this concern to a large degree.

In addition, the common cause failures included within the model (see Table 7-3) specifically address the potential consequences of any common failure mechanisms.

(b)

Specific examples illustrating how dependencies were considered forpre-initiator events modeled in the 1PE.

See response to (a) above.

(c)

Efdependencies and human action common-cause issues were not addressed for both miscalibrations and restoration events, pleasejustify.

See response to (a) above.

Rcsponsc io February 23, 1996 RAI POST-INITIATOR HUMANERRORS I

The submittal distinguishes human failure post-initiator events from recovery actions but does not clearly describe the method used to identify and select post-initiator human failure events for analysis (only a reference to the "HRA Task Procedure" is provided).

The method utilized should confirm that the plant emergency procedures,

design, operations, and maintenance and surveillance procedures were examined and understood to identifypotential severe accident sequences.

Please describe the process that was used foridentifying and selecting the post-initiator human failure events included in the event and fault tree models.

Section 4 addresses the success criteria used in the PSA with respect to four core protection functions and the specific need for operator action for each of these functions (see Table 4-10).

Section 6 describes all human actions related to each system.

Finally, Table 7-15 and Appendix F, Table F-4 describe the post-initiator human errors in detail.

The submittal is unclear on the basis for the quantitative screening approach that was used forpost-initiator human failure events.

Table 3.1.1-12 (or Table 3.1.2-12) indicates that screening values of0.1, 1.0, 0.21, and IE-4 were used.

Please provide the following:

(a)

The basis for the screening value(s) used and the rationale that led to assigning a given human action a particular screening value.

Please use several examples (at least two examples for each ofthe four screening values used) to illustrate how it was determined that a particular action would, be assigned one ofthe four values.

See Section 7.4.2.

In the revised PSA, the only screening value used was 0.1.

(b)

In addition to the examples used above, please provide the rationale for the screening values assigned to the following events: (1) AFHFDSAFWX-operators failto start standby auxiliaryfeedwater (SAFW) Pump IC and ID; (2)

AFHFDO4297 - operators fail to close air-operated valve 4297 to isolate steam generator (SIG) A, and (3) RCHFDOLBAF-operators failto initiatefeed and bleed.

Events AFHFDSAFWX, MSHFDISOLR (versus AFHFD04297) and RCHFD01BAF (versus RCHFDOLBAF) all used a screening value of 0.1.

Their final values are discussed in Appendix F, Table F-4.

(c)

Provide a rationale for how the selected screening value(s) ensured that I

L

Response to February 23, 1996 RA[

important post-initiator human events were not eliminated andlor important sequences truncated.

See Section 7.4.2.

Please provide a detailed discussion ofthe basis for assuming that an action was time independent.

Apparently, an action with more than an hour available was assumed to be time independent.

For these actions, what did "time available" refer to? Were the time required to perform the action and the temporaL occurrence ofcues relevant to a correct diagnosis considered?

This assumption is no longer used (see Section 7.4.2).

Appendix F, Table F-4 provides a description of the times used for human actions.

The values from Techniques for Human Error Rate Prediction PERP) that were used to quantify the time-independent events appear to ignore potential diagnosis errors and the associated performance shaping factors (PSFS) that might influence such diagnoses.

In addition, Chapter 15 ofthe THERP methodology discusses the table from which the time-independent HEPS were apparently takeri and notes that the values.may not be appropriatewhen symptom-based procedures are used.

Pleasediscussindetail whyit was unnecessary to consider potential diagnosis errors and the associated PSFs that might influence such diagnoses in quantifying time-independent events.

Also, provide the basis for the use ofvalues from Table 15-3 ofthe THERP when symptom-based procedures are being used.

The THERP approach is no longer used; instead the ASEP method per NUREG/CR-4772 was used (see Section 7.4.2).

In discussing the time-independent quantijication technique in Section 3.3.3.1.6 on page 3.3.3-3 ofthe submittal, itis stated in the thirdparagraph that "typically, the basic values given above were reduced by a factor ofthree in order to account for dependencies between events. " Please explain what is meant by this statement and illustrate how the reduction is used to account for dependencies.

Please provide several examples that illustrate the process.

This approach is no longer used for dependicies (see Section 7.4.2.).

Instead, all cutsets with multiple post-initiator operator actions were identified and further evaluated to determine ifthe human failure probabilities should be adjusted (see Tables 7-14 and 7-,15).

The submittaL is unclear on how the "time-dependent" quantification technique was applied to those post-initiator hunran events surviving initiaLsequence quantification.

Rcsponsc to Fcbniory 23, 1996 RAI The submittal presents two "time-dependent" quantification tables (Tables 3.3.3-l and 3.3.3-2), which were used to generate HEPS for human events depending on whether a given action could be considered rule-based with hesitation or rule based without hesitation.

Please describe the meaning ofthe parameters listed at the top ofthese tables (m= 2 min., EF. EFJ and the digits 0 through 9 at the top ofthe columns ofthe tables.

So, provide the following:

(a)

Using three or more examples, please illustrate how the various parameters of the tables were considered in determining HEPS.

Please provide examples that illustrate whether the values in the column headings were relevant and discuss

'ow it was determined whether or not a particular action was "withor without hesitancy. "

This approach is'no longer used (see Section 7.4.2).

On page 3.3.3-7, itis noted that for the operator action to cool down to residual heat removal (RHR) after safety injection fails, "explicitguidance on procedure transitions is not provided" and that successful performance would require a "circumvention. " Yet, the HEP of 1.8E-3 would seem to be optimisticfor an action without clear procedural guidance.

Please provide a detailed description ofthe derivation ofthis HEP and aj ustijicationfor what appears to be an optimistic HEP.

This approach is no longer used (see Section 7.4.2).

Also, the above statement is incorrect in that there is procedural guidance for this action (see Appendix F, Table F-4, events RCHFDCDOSS and RCHFDCDTR2).

The submittal is unclear on what plant-specific PSFs were consider@i in determining HEPS for time-independent and time-dependent huma n actions.

This plant-specific information could include the size of the crew, the availability ofprocedures, and the training, stress, and human factors aspects of the control room, and so on.

On the basis ofthe discussion in Section 3.3.3.2, itwould appear that may ofthese types ofplant specific PSFs were not explicitly consdered. Ifany ofthese types offactors were considered, please provide a List and show (by example) how their influence was factored into determining the HEPS for the various events.

(Include examples of both time-independent and time-dependent events.) Ifnone ofthese factors were considered, pieaz provide a concise discussion ofthe, rationale andjustificationfor not considering such plant-specific information during the quantification ofpost-initiator human actions.

This type of information was incorporated using the ASHP methodology (see Section 7.4.2).

Response

to February 23, 1996 RAI 8.

HRA methods, in general, attempt to ronsider both the diagnosis portion or phase ofpost-initiator operator actions and the execution demands of the action.

Please discuss how these two different aspects ofhuman failure events were considered in determining post-initiator human failure probabilities with the time-dependent technique. Ifthe response execution phase ofthe action and the associated PSFs are not explicitly considered please provide ajustificationfor how the values obtained with the time-dependent technique accurately reflect human failure probability.

Both the diagnosis and execution r equirements of each human action were considered (see Section 7.4.2).

9.

On page 33.3-2, the submittal states that "estimates for the required timing of operator actions were determined with the assistance of the Accident Sequence Analysis Task Leader." Please provide a detailed discussion of the process for determining the time required to complete operator actions and indicate how it was ensured that the resulting estimates were not overly optimistic.

The timings used as discussed in huma n actions are described in Appendix F, Table F-4 10.

Itis not clearfrom the submittal how dependencies were addressed and treated in the post-initiatorHRA. The performance ofthe operator is both dependent on the accident under progression and the past performance of. the operator during the accident of concern.

Improper treatment of these dependencies can result in the elimination ofpotentially dominant accident sequences and, therefore, the identification ofsignificant events.

Please provide a concise discussion and examples illustrating how dependencies were addressed and treated in the post-initiator HRAfor all types of actions to ensure that important accident sequences were not eliminated.

The discussion should address the twofollowing points:

Human events are modeled in the fault trees as basic events such as failure to manually actuate.

The probability of the operator is performing this function is dependent on the accident inprogression-what symptoms are occurring, what other activities arebeing performed (successfidly and unsuccessfully),

and so on.

When the sequences are quantified, this basic event can appear not only in different sequences but in diferent combinations with different systems failures. In addition, the basic event can potentially be multiplied by other human events when the sequences that should be evaluated for dependent effects are quantifi ed.

Human events are modeled in the event trees as top events.

The probability ofthe operator's peforming this function is stilldependent on the accident progression.

The quantification ofthe human events needs to consider the different sequences

'22-

Rcsponsc to February 23, 1996 RAI and the other human events.

See Section 7.4.2.

11.

The submittaL states that the specific HFEs that required detailed analysis were all

, associated with in-control room actions.

Yet, at least one such action (CTHFDISOLA-operator action to isolate ruptured SG EMSOlA) apparently also required actions to be performed outside the control room.

In the discussion of this event on page 3.3.3-5, it seems that the potential failure ofactions outside the control room were ignored.

Please discuss how ex-control room actions were quantifiedfor this event or provide ajustification forwhyitMas unnecessary to do so. Provide the same discussion for any other HFEs that included ex-control rooni actions.

Both in-control room and ex-control room actions were modeled.

In addition, all activities required by operators in either scenario were considered in generating the final human error failure probability (see Section 7.4.2 and Appendix F, Table F-4).

The submittal is unclear on how recovery actions mre quantified. Although the discussion on page 3.3. 7-12 regarding the determination ofthe indices forperformance influencing factors is clear, the basis for the"multi-factored approach" is not provided.

That is, how was it ensured that the summation ofthe indices and the insertion ofthe overall index into the formula on page 3.3.7. 12 produced valid estimate ofhuman failure probability? There is no evidence provided that the method has been used outside ofthe Ginna IPE and no indication that it has been peer reviewed or "benchmarked" in any way.

Please provide a discussion addressing the validity of the quantification approach.

In addition, please provide the following:

(a)

At least four examples that illustrate all aspects of the application of the quantification technique corresponding to the recovery events nrodeled in the IPE.

InparticuIar, ilimtrate how HEPS are derived using the formula on page 3.3.7.12.

For two ofthe examples, address events (1) PRFISOALTCD -failure to cool down after steam generator tube rupture using steam dump or ruptured SIG and (2)

NRHLETDOWN-failure to locally isolate letdown valve AOV-371 using 204A.

This approach i s no longer being used.

As described in Section 7.4.2, recovery events were treated the same as post-initiator human errors.

In most cases, recovery events were added to the fault tree mod els in order to allow the events to be added only to the correct scenarios.

With res pect to the two events above, these are described in Appendix F, Table F-4, events RCHFDCDTR2 and CVHFD00371, respectively.

(b)

A brief description of each of the recovery events modeled (apparently seven of 1<csponsc to Fcbniory 23, 1996 RAI them) and the HEPS assigned to these human actions.

As described above, recovery actions were treated the same as post-initiator human errors.

See Appendix F, Table F-4.

13.

Guidance from NUREG-1335 requests the identification ofcore damage sequences that drop below the core damage frequency (CDF) screening criteria because the frequency was reduced by more than an order of magnitude by taking credit for operator actions.

In addition, information was also requested on the timing and complexity ofthe associated human actions.

Please identify the relevant sequences and provide a discussion of the related operator actions.

See Sections 9.1.2, 9.3.1.1, and 9.3.2.2.

14.

On page 3.3.8-1 7, the submittaL notes that the same techniques used to recover internally initiating sequences were used to recover flood-related sequences aef that previously refined HFEprobabilities were incorporated.

Was it necessary to modify any ofthe existing HFEs to reflectflooding conditions? Were any HFEs added to address potentiaL human isolation offlood sources? Ifthe answer to eitherquestion is yes, using examples please address how the operator actions were quantified. Ifthe existing HFE HEPS were not modified to reflect flooding conditions or flood-specifi human actions were not included, please discuss why it was unnecessary to do so.

A response willbe provided by September 30, 1997 following re-a nalysis of the flooding PSA.

15.

The submittal is unclear on what human reliabilityanalysis was perfumed during the Level 2 analysis.

Please provide the following regarding the HRAfor the Level 2-analysis:

(a)

On page 4-11 of the submittal (last paragraph), it is implied that the recovery measures considered in the Level 1 analysis are generally applied in the Level 2 analysis.

Please discuss how this was done and provide a list of the relevant recovery actions and their assocrited HEPS. Ifthe HEPS digered from those used in the Level 1 analysis, please describe how the HEPS were calculated.

A response willbe provided by May 1, 1997 following the new analysis of the Level 2 PSA.

(b)

Please list any additional operatorirecovery actions considered in the Level 2 analysis (e.g., "certain containment isolation recoveries "Pnd describe the technique used to quantify the event(s) through examples.

Response to February 23, 1996 RAI A response will be provided by May, 1, 1997 following the new analysis of the Level 2 PSA.

Rcsponsc lo February 23, 1996 RAI ENCLOSURE 3 LEVEL2 QUESTIONS Containment Wall Liner Isolation.

According to the Ginna Independent Plant Examination (IPE) submittal, there is a 1.25-inch thick liner insulation on the sidewalls to a point 15 feet above the spring line.

The liner insulation is a closed-cell polyvinyl chloride foanr insulation with low conductivity, low water absorption, and high strength and is covered with metal sheeting.

Please discuss how this insulation is modeled in the modular accident analysis program (MAAP) code model and the effect this insulation has on the ability ofthe containment structure to absorb heat.

The insulation was modelled in the MAAP code by developing a containment liner/wall "gap resistance" that offered equivalent resistance to heat flow. The nominal value for the thickness and thermal conductivity of the insulation were obtained from the UFSAR, and the gap resistance was calculated to be their ratio.

For conservatism, the thermal properties of the insulation were assumed not to degrade under severe accident conditions.

Since MAAP3.0B only allows one outer wall to exist in each containment control volume, the uninsulated portion of the outer wall of the containment was represented in the MAAP "upper compartment" and the insulated portion of the outer wall was represented in the

~

MAAP "annular compartment".

Since the upper and annular compartments experience very similar thermal-hydraulic conditions, this slight simplification does not impact the results.

The presence of the insulation largely decouples the insulated parts of the outer wall from the containment atmosphere over the time frames of interest in severe accident calculations.

This is partly responsible for the relatively short containment failure times calculated for sequences with quenched core debris and no containment heat removal, Reactor Cavity and Depth ofDebris in the Sump for a Flooded Cavity.

(a)

It is stated in the Ginna IPE subniittal that "the concrete thickness in the cavity away from the sump is 2.0 feet above the imbedded liner and 2.0 feet below the liner. Below the cavity sump the total thickness cfthe basemat concrete is 1.5 feet. "

However, Figure4. 1-1 indicates that the total basemat thickness in the cavity is 2 feet.

Please clarify this apparent discrpancy. Ifthe total thickness is 2 feet instead of4feet, please discuss how this would acct your analyis ofcontainment basemat meIt-through resulting from core-concrete interaction.

The thickness of the concrete basemat is as follows:

In the reactor cavity sump - 1.5 feet

Response to Febn>ary 23, 1996 RAI b.

In the reactor cavity (away from the sump) - 2 feet c.

The containment floor outside of the cavity - 2 feet above the liner and 2 feet below the liner.

Since the basemat was poured directly onto bedrock, basemat melt-through is a somewhat arbitrary definition of containment failure, and the rate at which fission products would be lost after the debris penetrates the basemat is not clear.

The basemat thickness affects the analysis only in the definition of the timing of late containment failures due to basemat melt-through.

Such sequences are represented by source term category (STC) case 12, for which containment failure was assumed to occur at the time when 1.5 feet of concrete attack had occurred, as would be appropriate for cases in which debris enters the sump.

In cases where debris does not enter the sump; the timing of containment failure would thus be slightly underpredicted in case STC 12 (i.e., is conservative); otherwise, the error in the submittal does not affect the results.

The Ginna cavity consists of a cylindrical portion with an attached rectangular volume, which contains the sump. A model developed by F. Moody was used in the Ginna IPE to estiniate debris spreading and the probability of the depth of the debris in the sump for a flooded cavity with no steam explosion.

Table 4.5-7 ofthe IPE shows that if50 percent ofthe total core debris is released upon vessel failure, the debris spread radius is 4. Imeters (m).

Since the distance from the centerline ofthe reactor vessel to the claest edge ofthe cavity sump is 7.8m, itis stated in the IPE that "spreading to cover the eitire cavityfor high debris masses (40-60%) may be possible, but not likely. Hence, a probability of 0.1 is assigned to the SUMP FULL branch and a probability of 0.2 is assigned to the PART FULL branch."

However, the 4. I-m debris spread radius is sigficantly greater than both the radius ofthe cylindricaLportion and the halfwidth ofthe rectangular portions ofthe cavity region, which is about 2m. The total area covered bya circle with a 4.1-m radius is about 53 m', which is also signijicantP greater than the totaL cavity area of29 it'i Please discuss how the effect of the restricted spread area in the reactor cavity is considered in the assignment ofthe probability values for debris depth in the sump and what the effect ofhigher probability values for debris in the sump would be on containment failure probabilities.

After investigating the assumptions used in the development of the Moody model, RGEcE agrees with the inference by the reviewer that it would have been more appropriate in an irregular geometry such as the Ginna Station reactor cavity to reformulate the model to calculate the spread area rather than spread r'adius. Ifthis is done, the model calculates that debris should spread to fillan area nearly twice that represented by the cavity floor.

This would imply that debris could be

Response to Fcbrunry 23, 1996 RAI expected to enter the cavity sump.

However, it should also be noted that the heat flux between the debris and the water is calculated in the Moody model by assuming that enhanced film boiling occurs at the surface of the debris.

The parameters used in the PSA analysis were drawn from Moody's paper and result in an assumed heat flux of about 800 kW/m'. Small scale experiments performed by Henry et al. to address the Mark I liner melt-through issue measured heat fluxes during the period of simulated debris discharge that were an order of magnitude larger than this value f1]. Ifsuch an augmentation in heat flux also occurred in the reactor case over the period of debris discharge, this would overwhelm the problem noted by the reviewer and prevent the debris from flowing to the sump.

Theofanous et al. [2] has criticized the experiments of Henry et al., since no analysis of debris flow regime was conducted.

Given the pressurized (150 psi) discharge of simulant core debris in the experiments, Theofanous et al.. noted that intense mixing created by melt splashing offthe floor and running up the side walls could explain the high measured heat fluxes.

However, for the Mark I transient (in which the water level is only -0.9 m deep, much less than the level. in the Ginna Station cavity if the RWST is discharged) Theofanous et al. agreed that rapid fragmentation and quenching-of the core debris would be expected as the debris traverses the water pool, and that a local pileup of debris immediately under the RPV failure location could occur.

The probability of the cavity sump being either partially or completely full of debris was estimated in the PSA for three separate ranges of debris mass discharged at vessel failure:

Fraction of debris discharged 1

Probability of Probability of

< 20 percent

> 20 and < 40percent

>'40and < 60percent 0.01 0.1 0.2 Impossible 0.05 0.1 Considering both the irregular cavity geometry and the likelihood of debris jet break-up and larger debris/water heat fluxes during the debris ejection phase, these probability values are still considered reasonable.

Recognizing that this was an uncertain issue, a sensitivity case was run as part of the PSA in which it was assumed that the probability of having a full sump was unity (except for the- < 20 percent discharged debris case in which the sump Rcsponsc to Fcbniary 23, 1996 RAI cannot filland the probability of a partly full sump was instead considered unity).

As discussed in Section 4.8.1.4 and Table 4. 8-4 of the March 15, 1994 submittal, the effect of this change was to increase the probability of source term category (STC) 12 (which represents late containment failure due to basemat melt-through) from 13 percent to 30 percent of the total CDF; the no containment failure STC was reduced by the same amount to about 16 percent of CDF. Note that even if heat transfer was assessed using the filmboiling assumption, the probability of a full cavity in the medium debris mass cases would be less than unity, and this sensitivity calculation therefore somewhat overstates the magnitude of the effect noted by the reviewer.

It is also worth noting that late basemat melt-through sequences such as STC 12 have low source terms and that the fission product releases in the Ginna Station PSA were dominated by containment bypass sequences which are unaffected by the spreading issue (see Question 9). Although the calculations for debris spread in the March 15, 1994 submittal were determined to be non~nservative, consideration of these other factors leads RGkE to believe that our results are acceptable.

Cut set (CSET) Structure and Power Recovery.

According to the IPE submittal, the CSET tree structure ofthe branch for recovery ofac power prior to vs Ifailure. (PRV) is identical to that shown in the tree structure leading to endpoints 1-46 in Figure 4.3-1. On the other

hand, the structure of the branch for the recovery ofpower prior to containment failure (PRC) is assumed to be identical to that Ieading to endpoints 1-8. Figure 4.3-1 shows that all core injection and recirculation systems (i.e., low-pressure injectioend recirculation and high-pressure injection and recirculation) areavailable for endpoints 1-8; while one or more of these systenis are not available for endpoints 9 to 36:

Please discuss why all these systenis are assumed to be available for the cases of power recovery prior to containment failure but some ofthe systems may not be available for the cases ofpower recovery prior to vesseL failure.

In Figure 4.3-1 of the March 15, 1994 submittal, branch 49 shows a blackout sequence where power is not recovered at all, branch 48 shows a blackout sequence where power is recovered prior to containment failure and branch 47 shows a blackout sequence where power is recovered prior to vessel failure.

Since branches 1-46 are non-blackout sequences, power recovery is not an issue in any of these branches and the questions of what injection systems are available are instead addressed.

Lxternal Cooling ofthe Reactor Pressure VesseL Itis stated in the submittal (page 4-4) that "whenever the contents ofthe RWST (refueling water storage tankJ are injected into the containment the cavity willbe completely filledand willremain filled. " Based on this statement, it seeins possible that the ex-vessel water ]nay provide suffVcient cooling to the core debris inside the vessel sothat vessel failure could be avoided or signijicantly delayed.

As a result, fission product production and release paths could be affected (e.g., in-vessel Rcsi) OI1SC 10 FC4fUllry23, 1996 RAI release from a dry debris bed versus ex-vessel release from a debris bed covered by water).

The release offission products to the environment may actually increase ifthe containment fails and externaL cooling was accounted forin the source term calculation.

Please discuss the potentiaL of ex-vessel cooling for Ginna and its effect on source term definition.

Because external cooling may maintain the reactor coolant system (RCS) at high temperature for a longer time, please also discuss the @ct of externaL vessel cooling on the probability of creep rupture of the RCS boundaries and the steam generator tubes and, consequently, the effect on containment performance and source terms for Ginna.

When the PSA was initiallyperformed, the subject of ex-vessel cooling of core debris in the lower head was being actively studied.

Another area of active research at that time was the expected mode of vessel. failure, primarily through the TMI Vessel Inspection Program (VIP). The PSA analysts judged it likely that vessel failure would occur at a penetration soon after core relocation, which was the assumed mode of vessel failure in the IDCOR program.

This made it unlikely that the debris could be retained in the lower

head, and for this reason, no credit was taken for debris retention in the RPV.

This assumption was considered a potential conservatism of the PSA.

More recently, a consensus appears to be developing that retention of debris in the lower.

head is fairly likely. For sequences with injection of the RWST, and containment heat removal available, this would serve to prevent vessel failure and thus the potential for containment failure.

RG8cE is unaware of any calculations of fission product release from debris being cooled in the lower head of the reactor vessel.

However, such releases would be expected to be very small in the long term, since debris temperatures would be relatively constant, the surface area would be small, and most importantly, there would be no sparging of the debris by gasses as is the case for the in-core and ex-vessel fission product release mechanisms.

Thus, cooling of the debris in the lower head is not expected to represent a new safety issue from the standpoint of fission product release from debris.

With respect to inducing the failure of RCS components, induced rupture of the hot legs is expected to occur long before debris relocation'o the lower head in high pressure accident sequences.

Hot leg rupture would depressurize the RCS and remove any threat to the steam generator tubes.

Recent calculations performed by both NRC contractors as well as the industry indicate that hot leg or surge line rupture is also likely in medium pressure sequences.

For sequences involving RCS pressures low enough not to result in an induced rupture of the hot leg or surge line prior to core relocation, subsequent thermally-induced rupture of the steam generator tubes is only credible and of concern if:

a.

The sequence is not a bypass event and the steam generators are initiallyintact (i.e.

sequence is not initiated by a steam generator tube rupture);

Rcsponsc to February 23, 1996 RAI b.

One or both steam generators are depressurized to pressures less than the RCS pressure (otherwise the steam generator tubes would be in compression rather than tension);

c.

The RCS pressure is significantly greater than the secondary side pressure so as to threaten the tubes but sufficiently small as not to have already caused an induced rupture of the hot leg or surge line; d.

'he affected steam generator(s) secondary side is dry so that the tubes are not cooled (otherwise thermally-induced rupture cannot occur); and e.

There is no supply of water to the debris (a continuous supply of water, i.e. from a RHR pump, would cover the debris and cool the RCS).

Past experience indicates that the most likely scenarios fitting these criteria are total loss of feedwater sequences involving LOCA(s) (e.g, large RCP seal LOCAs or open pressurizer safety or relief valves) which also result in one or more depressurized steam generators.

Given the presence of LOCA(s), one would not expect RCS pressure to be maintained significantly above the steam generator pressure after the water initiallyin the lower head or that supplied by the accumulators is boiled away and the RCS depressurizes.

For this reason, it is believed that induced rupture of the steam generator tubes caused by debris retention in the lower head is very unlikely.

Therefore, we conclude that failing to credit debris retention in the lower head of the RPV represents a conservatism of the PSA rather than a concern.

The Availabilityof Containment Fan Coolers and Containment Spr ays. In the IPE model, ifthe containment fan coolers are available, containment sprays in both the injection and recirculation modes are modeled as failed (page 4-13). Although both systems have the same effect on containment heat removal, their effect on source term definition may be diferent.

Sprays are usually credited with being more ejlicmt than fan coolers in removing fission products from the containment atmosphere.

Please state whether containment sprays are included in the MAAP model for source term calculation (for cases in which containment heat removal is available). Ifthey are, pleasej ustify the use ofcontainment sprays forsource term calculations in all sequences with ontainment heat removaL Ifthey are not, please estimate the potential source term mitigation effect achieved by the operation ofcontainment sprays.

None of the MAAPcalculations of representative source terms (MAAPcalculations STC l-STC 20) credited the sprays, consistent with the assumptions made in the sequence quantification.

For sequences in which the debris is water-covered in the containment and fan coolers were credited, the only substantial benefit from assuming that the sprays also

Response to February 23, 1996 RAI operate would be expected in non-containment bypass sequences involving early containment failure (especially those with large containment breech areas).

The high rate of removal of aerosols afforded by the sprays could be expected to reduce the source terms in these cases since the fission product release is determined by the relative magnitude of the rates of aerosol leakage and deposition.

Bypass sequences are unaffected by containment sprays (which usually do not operate anyway), and fan coolers would have sufficient time to be effective in sequences with late containment failure.

The source term categories involving early containment failure with containment heat removal are STCs 2, 3,.5, 13, and 14. Of these, STC 2 and 3 involve small containment leak areas and only STC 13 has a conditional probability greater than 0.1 percent.

STC 13 represents 3 percent of the CDF and is caused by a failure of containment isolation.

The calculated source terms for this sequence, shown in Table 4.7-2 of the March 15, 1994 submittal, are moderate, but are much less than those. resulting from containment bypass scenarios (STC 16, 18, and 20) which are also much more likely (over 40 percent of CDF). Thus, while neglect of the sprays represents a conservatism, primarily in that STC 13 may have too large a source term, inclusion of the sprays would have a negligible effect on the results as a whole.

If these results change significantly due to the re-quantification of the Level 1 sequences, operation of the sprays may need to be evaluated in the Level 2 update.

Steam Generator Tube Rupture (SGTR) Releases.

The IPE results show that the steam generator power-operated reliefvalve (PORV) cycles during and aftercore damage in 'about half of the SGTR events, and there is a stuck-open PORV in the remaining half of the SGTR events.

Please discuss how the probability ofsteam generator (SG) valve failure is determined in the analysis and how the effect of the harsh conditions (e.g., the flow of extremely high temperature gases with entrained debris) on the operation ofthe SG valves is considered in the analysis.

The steam generator PORV or atmospheric relief valve (ARV) failure probability is determined in the Level 1 data analysis portion of the PSA.

No adjustment to the ARV failure probability was made based on harsh conditions; however, this willbe considered in the update to the Level 2 PSA.

The Probability ofPower Recovery.

According to Table 4.3-2 of the IPE submittaL, the probability ofpower recovery prioIto vesseL failure is 0.622, and the probability ofpower recovery after vessel failure but prior to containment failure is 0.127. However, the plant damag e state (PDS) results show that among all station blackout sequences (included in PDS 2 through 8), S4 percent have power recovery after vessel failure but prior to containme ntfailure (PDS 7).

The recovery probability of O.S4 is much greater than the value obtained in the power re'covery analysis (0.127).

Please explain this apparent discrepancy.

Rcsponsc to I'cbrnnry 23, 1996 RAI The probability of power recovery for the Level 2 analysis was based on the Level 1 power recovery curve.

This has since been re-performed (see Appendix C). This curve willbe used when the Level 2 portion of the PSA is re-quantified.

Capacity of the Containment Vessel.

Section 4.4 of the IPE submittal discusses the evaluation ofcontainment ultimate strength

. According to the IPE submittal, the ultimate strength and failure modes ofthe Ginna containment were dete rmined why a finite element analysis performed by Ebasco Services.

However, the criteria used to determine the ultimate failure pressure are not discussed in the submittal.

In the IPE, the failure pressures obtained were assigned an uncertainty of 5 percent for containment failure evaluation.

The 5 percent uncertainty used in the Ginna IPE seenis to be less than that used in other IPEs.

The difference between the 5th percentile failure pressure and the median failure pressure for Ginna is much less than that found in other IPEs or in the NUREG-II 50 analyses.

Please discuss the criteria used to determine the containment failure pressures and the basis for the 5 pecent uncertainty associated with these pressures.

The Ebasco study separately considered gross failure of the containment and local failures caused by liner tears at containment penetrations.

The study used the ABAQUS and HEATING6computer codes, and was based on minimum steel and concrete properties as defined in the UFSAR and relevant material specifications.

Gross containment failure was associated with a rapid increase in plastic strain at 155 psia; specifically, this failure pressure corresponds to the achievement of 3 percent strain in the circumferential reinforcement at mid-containment height.

Liner tearing was evaluated by estimating the failure strain near penetrations.

Such locations are empirically associated with a three-dimensional state of stress, for which the value of the "triaxiality factor" can be bounded by 5.

The triaxiality factor allows the effective failure strain to be related to the known uniaxial elongation failure strain measured for the liner steel.

In this case, the uniaxial failure strain of 9.8 percent results in an effective failure strain of 0.6 percent.

Such a strain was observed in the finite element results at a pressure of 145 psia; the calculated strain increases rapidly above this

pressure, so any errors in the effective failure strain willresult in only a small change in failure pressure associated with liner tears.

Ebasco judged that the uncertainty in the results of the finite element analysis itself was 5 percent.

As discussed in Section 4.4.3 of the March 15, 1994 submittal, this value was taken to be the standard deviation of a normal distribution centered around the calculated failure pressure which was taken to.be the median.

As stated above, the Ebasco analysis was based on minimum material properties, and no uncertainty in material properties was considered in the analysis.

For this reason, the fragility curve developed in the PSA should be regarded as a representation of the uncertainty in the minimum failure pressure that is consistent with the various materials specifications.

Rcsponso to February 23, 1996 RAI Qualitatively, consideration of material property uncertainties would shift the fragility curve toward higher pressures and would broaden the distribution; the expected magnitude of the broadening is not known.

The Ginna Station composite fragility curve, Figure 4.4-3, spans a pressure difference of about 12 psid in going from the fifthpercentile to the median.

Comparison of the Ginna Station results to those shown for Zion in Figure 1-1 of Reference f3] indicates that this measure of uncertainty in the Ginna Station curve is actually larger than that estimated by one analyst (expert C), comparable to that estimated by a second (expert A), and much less than that estimated by a third (expert B).

Based on this comparison, it is believed that the Ginna Station fragility curve is conservative, but not to a substantial degree.

As noted in Section 4.8.1.3, sensitivity calculations indicate that the PSA results are insensitive to reasonable changes in the fragility curve.

Containment Isolation Failure.

-According to the IPE submittaL, loss of containment isolation sequences represents 3.0 percent ofthe total cue damage frequency (CDF), or 5.2 percent of the frequency for noncontainment-bypass CDF.

Section 3.2.1.3 provides a description of the containment isolation system and the operating experience of the containment isolation system at the Ginna plant.

Section 4.3.1.2.4 mentions that a fault tree was used for containment isolation quantification.

However, details of the analysis and the results are not provided in the submittal.

With respect to the analysis of containment isolation failure probability, NUREG-1335 (Section 2.2.2.5, page 2-11) states that "the analyses should address the five a@as identified in the Generic Letter, i.e., (1) the pathways that could significantly contribute to containment isolation failure, (2) the signals required to automatically isolate the penetrations, (3) the potential for generating the signals for all initiating events, (4) the examination of the testing and niaintenance procedures, and (5) the quantification of each containment isolation failure mode (including common-mode failure). " The 5 percent probability of containment isolation failure is significantly greater than that of most IPES.

Please discuss the significant containment isolation modes (e.g., the penetrations thatfail to isolate and the causes for isolation failure) obtainedjom the IPE analysis and for these major containment isolation modes discuss how the five areas listed above were addressed.

The five areas required to be evaluated by NUREG-1335 were, in fact, considered in the Level 2 PSA.

These areas were evaluated in detail in the Containment Isolation System Work Package and summarized in Section 3.2.1.3 of the March 15, 1994 submittal.

The 5 percent probability of containment isolation failure was due almost entirely to ISLOCA sequences.

These sequences have since been re-evaluated (see Section 8.2 of the new submittal) with significantly different results.

These new results willbe included in the forthcoming Level 2 re-analysis.

Additional details of the containment isolation analysis willalso be provided at that time.

Response to Pebniory 23, 1996 RAI 10.

Penetration Seal Failure.

Failure ofcontainment penetrations is dismissed in the Ginna IPE as a potential containment failure mode because the analysis in NUREG-1150 indicated that this failure mode was significantly less important than the overpressure failure ofthe containment cylinder wall (page 4-28 of the submittal).

Please provide a description ofthe seal materials used for the penetrations in Ginna, their properties, and the potentiaL harsh containment conditions to which they could be exposed.

On the basis ofthis plant-specific information, please explain how you concluded that the findings in the NIJREG-1 150 analysis cited in the submittal were applicable to the Ginna plant.

11.

Systematic Evaluation Program (SEP) Topic VIII-4, Electrical Penetrations of Reactor Containment provides detailed information about the penetration seal materials and their properties.

Reference [4] provides the NRC's safety evaluation of this topic.

UFSAR Section 3.11 and the MAAP runs made for the Level 2 analysis detail the containment conditions to which the containment penetrations are expected to be exposed.

The containment penetrations willbe evaluated using this information and the information in NUREG-1037, "Containment 'Performance Working Group Report".

The results of this evaluation willbe included in the forthcoming Level 2 re-analysis.

Containment Performance Improvement and Hydrogen Issues.

The generic letter containment performance improvement recom mendation forpressurized-water reactor dry containments is the evaluation ofcontainment and equipment vulnerabilities to localized hydrogen combustion and the need forimprovements (including accident management procedures).

Please discuss whether plant walkdown inspections have been performed to determine the probable locations of hydrogen releases into the containment.

Including the use of wakdown inspections, discuss the process used 5 assure that (1) local deflagrations would not translate to detonations given an unfavorable nearby geometryand (2) the containment boundary, including penetrations, would not be challenged by hydrogen burns.

Please identity potential reactor hydrogen release points and vent paths.

Estimates of compartmerit free volumes and vent path flowareas should also be provided.

Specifi cally address how this information is used in your assessment of hydrogen pocketing and detonation.

Your discussion (including important assumptions) shou ld cover the likelihood oflocal detonation and the potentiaL for missile generation as a result oflocal detonation.

A containment walkdown was performed on May 4, 1992 for the purpose of assessing containment features important for understanding the response of the Ginna Station containment during severe accidents.

One focus of the walkdown was to establish the most important inter-compartment gas flow paths.

The results of the walkdown indicate that:

a.

Substantial global natural convection currents would be expected in a severe 0

Rcs~) ollsc to Fcbnlary 23, 1996 RAI accident, driven primarily by heat loads from the RCS and where applicable, from debris in the containment, and by heat removal by the walls and active safeguards systems.

Gas flow is expected to occur upward in the lower compartment region surrounding the RCS components and through grating over the reactor coolant pumps and the annular regions around the steam generators and pressurizer.

The gas willflow into the upper dome where it willcool by contact with uninsulated heat sinks (and spray droplets where available), and flow down the annulus outside the shield wall. From the outer containment annulus, the gas willflow back to the lower compartment region through two stairwells, grating, and open areas around HVAC ducting located at the 253'levation.

b.

The limiting flow area on this circulation loop is quite large, about 450 square feet f5].

Driven solely by the nominal heat losses from the RCS, the. overall containment mixing time is calculated to be only -6 minutes [5]. In actuality, this calculation underpredicts containment mixing since the effect of containment heat removal systems has been neglected; sequences without containment heat removal operational willresult in too high a steam concentration to result in deflagrations, much less deflagration to detonation transition (DDT).

The principal hydrogen release points to the containment prior to RPV failure are RCS breaks in the regions surrounding the coolant loops or the pressurizer relief tank rupture disk for sequences with no cycling or open pressurizer safety or relief valves.

All of these locations are well-ventilated, have substantial flow areas available directly ov'erhead, and thus do not pose a threat of localized hydrogen build-up. Hydrogen released to these locations would be expected to be entrained into the overall containment circulation and mixed with the other gasses as they flow into the upper dome region.

d.

Diffusion flames occurring at any of these hydrogen release points inside the shield wall would not endanger containment penetrations.

Global hydrogen burns would be of short duration and would not be expected to threaten the penetrations.

Ifone assumes that hydrogen released to containment is well-mixed, the potential for DDT can be qualitatively assessed by calculating the maximum average hydrogen concentration that can be achieved.

Even ifall the zirconium in the core is oxidized (a more realistic upper bound is about 75 percent), the hydrogen concentration in the containment would be only 11 percent in the complete absence of steam.

In actuality, some steam would always be in containment during a severe accident.

Also, it is very unlikely that such a large amount of hydrogen could be released to containment so quickly as to avoid deflagrations at lower hydrogen concentrations.

Allof these considerations would limit the peak achievable hydrogen concentration.

In any event, 11 percent is too small to support DDT, even for geometries that promote flame acceleration.

Response to February 23, 1996 RAI Additional hydrogen and carbon monoxide could be released during core-concrete interactions (CCI) as steel in the core debris or basemat reinforcement is oxidized.

However, the release of combustible gas from steel oxidation in CCI would occur relatively slowly, would be accompanied by diluents such as carbon dioxide and steam, and would promote mixing in the containment.

Thus CCI would also be very unlikely to result in combustible gas concentrations sufficient to cause DDT.

High. combustible gas concentrations could potentially be created if containment heat removal was restored after a long period of CCI.

In the PSA, STC 9 represents a

sequence in which a late deflagration is initiated that causes containment failure. In fact, experiments suggest that burns willbe initiated as soon as sufficient steam is condensed that. the containment gas is no longer inerted [6].

These burns are observed to be so incomplete that no significant pressurization of the containment results (except when near-stoichiometric mixtures are created).

Again, detonations are unlikely.

Based on these considerations, the threat of hydrogen detonations is judged to be very small in the Ginna Station containment.

This is consistent with past studies on other PWR large, dry containments [7].

Equipment Survivability.

The availability of containment fan coolers and containment sprays is considered in the plant damage state (PDS) defi nition ofthe IPE.

The effect of harsh environmental conditions on the operation ofthis equipment are not discussed in the containment event tree (CETI quantification ofthe 'submittal Please provide a description ofhow the survivability ofthis equipment under severe accident conditions was evaluated.

Please includein the discussion the environmental conditions (e.g., temperature, pressure, radiation, and debris) derived and used in the evaluation.

The Level 2 PSA did not consider the effect of environmental conditions on the operability of these systems.

To our knowledge, previous analyses have not concluded that containment spray operation would be threatened by containment conditions, except perhaps those resulting in catastrophic containment failure. For example, in the NUREG 1150 study on Zion [8], only a 10 percent likelihood was assigned to failure of containment sprays following catastrophic containment rupture; sprays would be relatively ineffective in reducing source term after gross containment failure in any event.

The Zion NUREG 1150 study did not explicitly consider the deleterious effect of containment conditions on the fan coolers at all (see APET questions 24, 43, 45, 46, 53, 65, and 66)

[8]

To assess whether the Ginna Station fan coolers would continue to operate in a severe accident, the MAAP calculations used to characterize the various source-term categories were reviewed.

This set of calculations is useful for representing the spectrum of accident calculations that could be encountered in a-severe accident.

As noted previously,

Rcsponsc to Fcbnmry 23, 1996 RAI containment sprays were not credited in these calculations; for this

reason, gas temperatures would be somewhat higher than expected in sequences where the sprays were actually available.

STCs 2, 3, 4, and 12 involve operable fan coolers prior to vessel failure. The MAAP-calculated conditions in these sequences were compared to the design basis envelope for the fan coolers described in Chapter 6.1.2 of the UFSAR.

The pressure and radiation conditions specified for the DBA are generally more severe than the severe accident conditions that would be encountered for all sequences not involving a late recovery of containment heat removal.

STC 9 involves a late recovery of fan coolers which gives rise to a late failure of containment from a hydrogen burn; failure of the fan coolers to operate in this sequence would not therefore lead to higher risk, as calculated by the PSA.

Since the fan coolers. are located in the annular region outside the primary component shield walls and take suction there, the MAAP-calculated ga's temperatures in this region were used to assess the threat from high temperatures.

For all but STC 9, gas temperatures are less than the DBA envelope (286 F for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />) except for brief spikes observed during hydrogen burns.

Since the spikes are of short duration, it is judged that the fan coolers would survive these events.

In this regard, it should be noted that the Ginna Station fan cooler motors are actively cooled by service water and also that the TMI fan coolers continued to operate after the global hydrogen burn that occurred during the accident [9].

It is noted that a possibility exists that the fission product filters could become clogged due to high aerosol loadings during a severe accident.

This should not threaten the effectiveness of the fan coolers since only 2 of the units have filters and since the filters can be manually bypassed.

Therefore, we conclude that operation of the fan coolers and sprays is unlikely to be threatened by the environmental conditions in the containment and no changes are required.

EVNTREEvents.

In the Ginna IPE, a small CETis developed for accident progression analysis.

The top events ofthe CET are determined in the IPE by the use ofdecomposition event trees PETs).

The event progression analysis code EVNTRE, which was developed and used in the NUREG-1 150 analyses, is used for event tree quantification in the IPE.

To use the code, the top events developed in the Ginna event trees are numbered and incorporated into the EVNTRE model.

The highest number for the EVNTRE events that can be identifiedfrom the trees in the Ginna submittal is 47.

This seems to indicate that there are 47 events (or questions) in the EVNTRE modeL However, examination ofthe event trees in the Ginna IPE shows that the total number of events in the trees is less than

47. As a result, some EVNTRE questions (e.g., 14, 17, 18, etc..) cannot be identifiedfrom

Rcsponsc to February 23, 1996 RAI the Ginna event trees presented in the submittaL Please provide a list of all ENTRE questions used in the Ginna analysis and discuss the questions that are in the EVNTRE model but not in the Ginna event trees.

A complete listof the EVNTRE events in the CET is provided in Table 1 at the end of this section.

The first 12 events in the model correspond to the top events shown in Fig 4.3-2 of the March 15, 1994 submittal.

The remaining events are either described in the text of the submittal or are "dummy" events included for the convenience of the analyst that do not affect the results.

The dummy events are numbered 14, 17, 18, 27, 29, 31, 35, 37, 38, 40, 41, and 45. Allnon-dummy events were described in the submittal.

Modular Accident Analysis Program (MAAP) Calculation Results.

A number ofMAAP calculations were performed in the Ginna IPE to provide data for the accident progression analyses. A briefdescription of each ofthese accident progression cases is given in Table 4.6-1 ofthe submittaL MAAPcalculations were also performed to derive release fractions for the various source term categories.

Briefdescriptionof these source term cases are also provided in Table 4.6-1. It can be seen that the conditions of Case MLOCA03 (page 4-150) and Source Tenn Case STC12 (page 4-161) are similar. For both cases, the auxiliary feedwater (AFW)is available and the safety injection system is unavailable.

However, the core uncovery time and the vessel failure time shown in Table 4.6-1 are significantly different for these two cases (they are 4.27 and 5.96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br />, respectively, for Case MLOCA03, and 0.7 and 1.55 hours6.365741e-4 days <br />0.0153 hours <br />9.093915e-5 weeks <br />2.09275e-5 months <br />, respectively, for Case STCI2).

Please discuss the reasons for the time difference between these two cases, vhere and how each case was used in the IPE analysis, and the impact ofthe data from each case on IPE quantification.

As used in Table 4.6-1, "No SI" refers to the unavailability of high pressure injection.

Cases with no safety injection at all (i.e., high and low) are labelled "No injection" (see for example case SLOCA00). The apparent discrepancy between the two cases cited is caused by the availability of low pressure injection in MLOCA03 which delays core uncovering and vessel failure relative to case STC 12 which involves a complete failure of all active injection systems.

The results of MAAPcalculations were used in the Ginna Station PSA to assess sequence timing (see, for example, the discussion in Section 4.3.1.1.2),

to obtain insights useful for the quantification of the CET (e.g., events such as induced rupture of the RCS, direct containment heating, deinerting the containment atmosphere, etc.), and.to assign explicit source terms to source term categories.

This is discussed in Sections 4.5, 4.6, and 4.7 of the March 15, 1994 submittal.

The results from MAAPcalculation MLOCA03 were not used explicitly in the PSA and were performed simply to provide the analysts a qualitative understanding of the effect of break size and safety injection system availability on sequence timing.

The results of

Rcsponsc to February 23, 1996 RAI calculation STC 12 were directly used to assign source terms to the associated source term category.

Sequence Selection for Source Term Determination.

It is stated in the IPE submittal (Section 4.7.3) that "specific accident progression sequences were chosen to best approximate the representative source tenn results for each relevant Source Term Category (STC) end state.

Based on consideration ofthe dominant sequence for each end state and based on other factors which influence t@ source term results, representative sequence descriptions were developed to perform MAAPcalculations to quantify the source terms. "

However, in the submittal, the PDSs that contribute to the STCs are discussed onlyfor a few STCS, and for some ofthese cases the sequences selected forMAAPcalculations are not the dominant sequences in the PDSS.

For example, according to the submittal; PDS 15 and PDS 17 represent the majority of STC 2. The representative sequence chosen to represent this STC is a medium-break loss-of-coolant accident (LOCA) sequence.

However, according to Table4.3-5 ofthe submittal, the sequences that contribute to these PDSs are small LOCA or reactor coolant pump (RCP) seal LOCA sequences, and medium LOCA sequences are not involved in either of these two PDSS.

There is no discussion in the submittal why a medium LOCA instead ofa small LOCA sequence was chosen to represent this STC.

Please provide a complete list ofthe contributing PDSs for all the STCs and provide the rationale for the selection of each ofthe sequences chosen to-represent the STCS.

Contributing PDSs are not discussed for each of the STCs because of the many STCs that a PDS might contribute to and because of the low probabilities associated with a number of the STCs.

For example, PDS 2 comprises only 0.35% of the PDSs per Table 4.3-4.

Almost 69% of PDS 2 contributes to STC 15, but it is still not a significant contribution since the PDS is of such a low frequency (about 23% of PDS 2 contributes to STC 1 and the remaining 8% contributes to 6 other STCs).

The following is a listing of the top 11 PDSs per Table 4.3-4 and the STCs they primarily contribute to in approximate percentages:

PDS 12 contributes to STC 1 (72%) and STC 12 (28%)

PDS 22 contributes to STC 18 (100%)

PDS 24 contributes to STC 20 (100%)

PDS 20 contributes to STC 16 (100%)

PDS 15 contributes to STC 1 (59%) and STC 12 (41%)

PDS 17 contributes to STC 1 (97%)

PDS 11 contributes to STC 15 (95%)

PDS 1 contributes to STC 13 (100%)

PDS 9 contributes to STC 15 (65%), STC 1 (21%) and STC 12 (13%)

PDS 7 contributes to STC 9 (48%) and STC 14 (48%)

PDS 14 contributes to STC 12 (100%) - "

Response to Pcbnmry 23, 1996 RAI The source term characterization was considered less important than the characterization of the core damage sequence and the achievement of an overall understanding of containment performance.

Selection of sequences to represent STCs was primarily guided by a desire to:

Represent the key phenomenological effects that were used to characterize the STCs.

These effects, e.g. the occurrence of CCI, availability of water on the debris, availability of containment heat removal, size and timing of containment failure, etc. are shown in Figure 4.7-1 of the March 15, 1994 submittal.

Break size was not considered sufficiently important to be used in the classification of source term categories, although it does affect the degree to which fission products are retained in the RCS.

b.

Minimize analytical effort for sequences which do not contribute significantly to the risk As described in Section 4.7.3.1, STC 2 represents sequences with vessel failure, a leak-type early containment failure, containment heat removal, and no sustained CCI. As such, the source term is dominated by the release of fission products from the vessel in the period just leading up to and following vessel failure. A medium LOCA sequence was chosen to reduce in-vessel retention of fission products so as to provide a conservative, yet reasonable assessment for the various PDSs comprising this release category.

Note also in Table 4.7-1 that STC 2 represents less than 0.1 percent of the CDF.

By contrast, STCs 16, 18, and 20 represent nearly half the CDF and all involve bypass of the containment. Allthree of the latter sequences can a priori be expected to have the largest source terms, at least as modeled by MAAP. These source terms are probably over-predicted by the MAAPcalculation since the code neglects turbulent deposition in piping (STC 16) and on the secondary sides of the steam generators (STCs 18 and 20) and since retention of fission products in the auxiliary building was not modeled (STC 16). In any event, given the MAAP-calculated source terms, negligible errors are incurred in the results as a whole by failing to more precisely model sequence-specific aspects of the much lower-probability end states such as STC 2 that have relatively small fission product releases.

16.

Induced SGTR The Likelihood ofinduced hot leg or steam generator tube ruptures in high pressure scenarios is analyzed in the Ginna IPE using MAAP analysis data and an empiricaLformula, developed by Larson and Miller, relating the expected time to rupture with temperature and stress.

Since the conclusions from this analysis are consistent with the results from the NUREG-1150 data for Surry, the probability values used in the NUREG-1150 Surry anal ysis are used in the Ginna IPE. It should be noted that in some IPES the probability ofinduced SGTR due toforced circulation caused by the restart ofthe 0

Response

to Febn>ary 23, 1996 RAI RCPs is addressed because the insujlicient core cooling (ICC) guidelines callfor the RCPs to be restarted.

Please discuss whether there are procedures at Ginna that callfor the restart ofthe RCPs and, ifthere are, please discuss theirgect on the probability ofinduced SGTR.

Ginna Station Procedure FR-C.1, Response to Inadequate Core Cooling, potentially calls for restart of the RCPs after the core is uncovered.

During the time frame "when the PSA was being performed, concern was expressed that this might cause an increase in heat transfer from the core to the steam generator tubes, potentially causing their failure. This concern would only be relevant in the relatively small number of sequences in which the secondary side of the steam generators was dry, RCPs were available, and RCS pressure was elevated compared to the steam generator pressure.

In any event, this issue was not addressed in the Ginna Station PSA.

The current version of the procedure, revision 10 dated 11/29/95, calls for an RCP to be restarted in a given loop only ifthe narrow range level exceeds 5 percent in the associated steam generator (see step 23).

This ensures that the affected tubes will be cooled and eliminates concerns for thermally-induced tube rupture.

17.

Typographical Errors (a)

AC power recovery considers only the recovery ofoff-site power.

The recovery of DGs is not credited. Itseems that therei a typographical error in Table 4.3-2.,The probability ofpower non-recovery at 21 hours2.430556e-4 days <br />0.00583 hours <br />3.472222e-5 weeks <br />7.9905e-6 months <br /> should be 0.00$ 66 instead of0.0$66 shown in the table.

The typographical error willbe corrected during the new Level 2 analysis.

(b)

The title of Reference 4.9-I9 of the submittal is given as "Evaluation of Severe Accident Risks: Ginna UnitI ". Itshould be "Surry Unit 1" instead of "Ginna Unit g

It The typographical error willbe corrected during the new Level 2 analysis.

(c)

Event 9 ofthe CET top event "Ex-Vessel CCI" is described in the submittal (p4-74) as CAV WAT F. However, itis described as L RWSTin the CCIdecomposition event tree (Figure 4.$-6, Paragraph 4-l96).

The typographical error willbe corrected during the new Level 2 analysis.

Rcsponsc to February 23, 1996 RAI 1.

E. Fuller, ed., Containment Performance and Fission Product Release Determination for Individual Plant Examinations (IPES), Proceedings of a Workshop in Chicago, IL, July 1989, Electric Power Research Institute.

These results are also reported in R. E. Henry et al., "Experiments Relating to Drywell Shell-Core Debris Interactions", Proc.

16th Water Reactor Safety Information Meeting, Gaithersburg, October 24-27,

1988, NUREG/CR-0097.

2.

T.

G.

Theofanous and H. Yan, "The Probability of Liner Failure in a Mark-I Containment, Part II: Melt Release and Spreading Phenomena",

Nucl. Tech., 101, March 1993.

3.

R. J. Breeding et. al, Evaluation of Severe Accident Risks: Quantification of Major Input Parameters, NUREG/CR-4551, Vol. 2, Rev. 1, Part 3.

4.

Letter from D.M. Crutchfield, NRC to J.E. Maier, RG&E,

Subject:

SEP Topic VIII-4, Electrical Penetrations of Reactor Containment Safety Evaluation Report for R.E. Ginna Nuclear Power'lant", dated October 8, 1981.

5.

Memorandum from M. Kenton (D&M)to Daphne Mays (RG&E) dated July 16, 1996.

~

~

~

6.

T. Blanchat and D. Stamps, "Deliberate Ignition of Hydrogen-Air-Steam Mixtures Under Conditions of Rapidly Condensing Steam", SAND 94-3101C, January 1995.

7.

J.W. Yang, Z. Musicki, and S. Nimnual, Hydrogen Combustion, Control, and Value-Impact Analysis for PWR Dry Containments, NUREG/CR-5662, BNL-NUREG-52271, June 1991.

8.

C. Park et. al, Evaluation of Severe Accident Risks, Zion, Unit 1: Appendix A.,

NUREG/CR-4551 Vol. 7 Rev 1 Part 2A, March 1993.

9.

J. O. Henrie and A. K. Postma, Analysis of The Three Mile Island (TMI-2) Hydrogen Burn, RHO-RE-SA-8 P, Rockwell International, October 1982.

Rcsponsc to February 23, 1996 RAI Table 1

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Containment Bypass Sequence Containment Isolation Status Transient or LOCA Type Reactor Shutdown Station Blackout Power Recovery RCS Pressure at Core Damage Status of In-Vessel Injection Containment Fan Coolers Containment Spray Status Steam Generator Isolated Steam Generator Break Covered Mode of Induced RCS Failure Dummy RCS Pressure at Time of RPV Failure Debris Cooled In-Vessel Dummy Dummy In-Vessel Steam Explosion Fails Containment RWST Injected Early Containment Atmosphere Inert Mass Debris Expelled Early Fraction Debris Involved in DCH Fraction Debris Dispersed Outside Lower Compartment Fraction Debris Metal Reacted Hydrogen Burn Dummy Early Containment Failure Dummy RWST Injected Late Dummy Debris Depth Against Liner Containment Liner Meltthrough Steam Explosion Disperses Debris Dummy Depth of Debris in Sump Dummy Dummy Type of Ex-Vessel CCI Dummy

Response to February 23, 1996 RAI Table 1 Continued 41 42 43 44 45 46 47 Dummy Power Available Prior to RV Failure Power Recovery Late Containment Heat Removal Dummy Late H2 Burn Fails Containment Mode of Late Containment Failure