WPPSS NUCL'EAR PROJECT NO.
2 REPORTABLE DEFICIENCY AND CORRECTIVE ACTION FOR DESIGN OF SMALL DIAMETER.(2" and under)
PIPE WITH WAL'L THICKNESS LESS THAN SPECIFIED REQUIREMENTS WASHINGTON PUBLIC POWER SUPPLY SYSTEM DOCKET NO. 50-397 LICENSE NO.
CPPR-93 DESCRIPTION OF DEFICIENCY Carbon steel small diameter pipe has been installed with less than the minimum allowable wall thickness specified for the applicable pipe schedule.
This condition occurred when the Mechanical Installation Contractor (215) utilized grinders and other power tools to remove oxide-and mill scale, from the pipe in preparation for welding.
The wall thinning is localized at the ends of the pipe at socket. weld joint.
SAFETY SIGNIFICANCE Failure of the carbon steel small bore diameter pipe could result in the failure of safety related system components, adversely affecting the s a fe opera tion of the pl ant.
CORRECTIVE ACTION Contract 215 has issued instructions to their personnel to use wire brushes instead of grinders when preparing pipe for welding and their work procedures are being revised accordingly.
A technical evaluation'of the condition identified via Nonconformance Report No.
215-05196 is being performed by the A/E. It is anticipated that wall thickness measurements and design evaluation will be performed for the affected high pressure systems.
Any socket weld connections which do not satisfy the minimum design wall thickness requirements will be corrected.