ML16209A226
| ML16209A226 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 07/18/2016 |
| From: | Connolly J South Texas |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| GSI-191, NOC-AE-16003368, TAC MF2400, TAC MF2401 | |
| Download: ML16209A226 (35) | |
Text
.\\
South Tt'A:ls Project Electric Ge11eratl11g Sl1llon P.O. Bar 28!1 Watlsll'ortk Texas. 77'/SJ U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 July 18, 2016 NOC-AE-16003368 10 CFR 50.12 10 CFR 50.90 Third Set of Responses to April 11, 2016 Requests for Additional Information Regarding STP Risk-Informed GSl-191 Licensing Application (TAC NOs MF2400 and MF2401)
References:
- 1. Letter, G. T. Powell, STPNOC, to NRC Document Control Desk, "Supplement 2 to STP Pilot Submittal and Requests for Exemptions and License Amendment for a Risk-Informed Approach to Address Generic Safety Issue (GSl)-191 and Respond to Generic Letter (GL) 2004-02", August 20, 2015, NOC-AE-15003241, ML15246A126
- 2. Letter, Lisa Regner, NRC, to Dennis Koehl, STPNOC, "South Texas Project, Units 1 and 2-Request for Additional Information Related to Request for Exemptions and License Amendment for Use of a Risk-Informed Approach to Resolve the Issue of Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized-Water Reactors", April 11, 2016, ML16082A507 Reference 2 transmitted RAls on STPNOC's application in Reference 1 and divided the RAls into 3 sets to be responded to in 30-day intervals. This submittal responds to the third set of RAls.
STPNOC is responding to the SNPB RAls in a separate submittal.
There are no commitments in this submittal.
~#
STI 34306885 \\S
NOC-AE-16003368 Page 2 of 3 If there are any questions, please contact Mr. Wayne Harrison at 361-972-8774.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on:
() 7f rr/IJ awh Attachments:
- 1. Response to Follow-up RAls 33 and 34
- 2. Response to SSIB-3-4 through 7
- 3. Response to STSB-3-1
- 4. Response to SCVB-3-1
- 5. Definitions and Acronyms
cc:
(paper copy)
Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Lisa M. Regner Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (08H04) 11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN116 Wadsworth, TX 77 483 (electronic copy)
NOC-AE-16003368 Page 3 of 3 Morgan. Lewis & Bockius LLP Steven P. Frantz, Esquire U.S. Nuclear Regulatory Commission Lisa M. Regner NRG South Texas LP Chris O'Hara Jim van Suski!
Skip Zahn CPS Energy Kevin Pollo Cris Eugster L. D. Blaylock Crain Caton & James. P.C.
Peter Nemeth City of Austin Elaina Ball John Wester Texas Dept of State Health Services Helen Watkins Robert Free Response to Follow-up RAls 33, 34 NOC-AE-16003368
Head Loss and Vortexing NOC-AE-16003368 Page 1 of 6 Follow-up RAI 33 - In the December 23, 2009, RAI, the NRC staff asked the licensee to provide the margin to flashing across the strainer and debris bed, and the assumptions for the calculation.
The licensee provided a calculation for the margin to flashing for large break loss-of-coolant accidents (LOCAs) at the start of recirculation as (in pounds per square inch [psi]):
Containment pressure + submergence - total strainer head loss - vapor pressure
= 43.1 + 0.3 - 1.5 - 39
= 2.3 psi The licensee stated that post-LOCA containment over-pressure credit is needed to eliminate the potential for flashing.
The licensee stated that the minimum strainer submergence was conservatively determined to be 0.5 inch for small break LOCA (SBLOCA), sump temperature and containment pressure would be lower for a SBLOCA than a large break LOCA (LBLOCA),
strainer flow rate would also be lower, and debris transported to strainers would be much less such that there would be open strainer areas. Therefore, flashing is not expected to be an issue for SBLOCAs. The NRC guidance1 is that sump temperature should be calculated conservatively high and containment pressure conservatively low to ensure no flashing will occur. It is acceptable to perform a time-based calculation taking viscosity, chemical timing, and strainer submergence into account. Most design basis calculations maximize containment pressure, which is non-conservative from a flashing perspective.
Please explain in detail how sump temperature and containment pressure were calculated.
STP Response:
For each large break LOCA analyzed, two cases are performed. One case is to maximize the Containment pressure and the other is to maximize the Containment temperature.
These methods follow the input guidelines for containment pressure and temperature analysis provided in Table 3.6.1 of DOM-NAF-3, "GOTHIC Methodology for Analyzing the Response to Postulated Pipe Ruptures Inside Containment," November 6, 2006 (ML063190467). STPNOC selected the maximum sump temperature using the split heat transfer option as described in Section 3.3.2 of DOM-NAF-3.
STPNOC has not specifically analyzed the sump temperature using the cited NRC guidance.
1 "Revised Content Guide for Generic Letter 2004-02 Supplemental Responses, November 2007
(ADAMS Accession No. ML073110278), and Regulatory Guide 1.82, "Water Sources for Long-Term Recirculation Cooling Following a Loss-of-Coolant Accident."
Head Loss and Vortexing Follow-up RAI 34 NOC-AE-16003368 Page 2 of 6 In the December 23, 2009, RAI, the NRC staff asked the licensee to provide an evaluation of the potential for deaeration of the fluid as it passes through the debris bed and strainer and whether any entrained gasses could reach the pump suction. The licensee stated that the net void fraction is 0 percent, and therefore, void fraction is not an issue for any of the pressure and temperature combinations associated with the post-LOCA fluid. The licensee explained that any void fraction that could occur at the strainer debris bed is minimal and that if any should occur, it is reversed before the strainer discharge water leaves the sump due to significant static head of water above the emergency core cooling system (ECCS) I containment spray system (CSS) pump suction inlets within the sump. The licensee concluded that the net void fraction is therefore zero and not problematic for any STP pressures and temperatures from the strainer to the ECCS/CSS pump suction inlets within the sump. With respect to the RAI response:
a)
Do the head loss values listed include clean strainer head loss?
b)
How was the SBLOCA value determined?
c)
Was containment spray head loss (CSHL) calculated separately?
d)
Is the SBLOCA value less than the CSHL value alone due to the lower flow rate?
e)
Since head loss is greater at lower temperatures and solubility is greater at lower temperatures, were any evaluations done at lower.and higher temperatures to ensure the provided calculation is bounding?
f)
As with the flashing evaluation, it is acceptable to use a time-based calculation that includes submergence, temperature, chemical timing, etc. If the values used in the deaeration evaluation are not considered to be design basis values, please provide information regarding how they were calculated. Please provide the design basis values for head loss, SBLOCA, CSHL, and the associated conditions.
g)
The NRC staff understands that gas voids will decrease in volume as pressure increases. However, reabsorption of gasses into the fluid may not occur instantly.
Please explain what is meant by the reversal of the void fraction due to the static head of the water.
STP Response
- a. The values for total head loss found from July 2008 testing (6.504 ft-water and 0.8717 ft-water [1] ) listed in the response to 2009 RAl-34 include a clean strainer loss of 0.8717 ft-water, consistent with the approach velocity at the LBLOCA flow of 7,020 gpm and corrected to a temperature of 171°F. The clean strainer head loss contribution to these values is found by applying a temperature correction to the design clean strainer head loss* value (CSHL) of 1.952 ft-water [2], splitting out the plenum contribution to this CSHL value, and adding the plenum contribution to the CSHL value found during the July 2008 strainer testing [1].
NOC-AE-16003368 Page 3 of 6
- b. The SBLOCA total head loss value (0.8717 ft-water) provided in the 2009 RAl-34 response was reported as equivalent to the clean strainer head loss for the LBLOCA scenario. The total head loss was calculated as the sum of the plenum head loss from the design calculation [2] and the July 2008 tested clean strainer head loss [1 ]; where the clean strainer head loss from the July 2008 test only accounted for losses across the clean screen. The LBLOCA scenario is more bounding for void fraction analysis due to the larger flow rate and the debris-induced head loss.
- c. The head loss values (6.504 ft-water and 0.8717 ft-water [1] ) provided, reflect total strainer head loss calculated from the July 2008 test. These total strainer head loss values include the clean strainer head loss (CSHL), and result from flow contributions from a containment spray (CS) pump, a low head safety injection (LHSI) pump, and a high head safety injection (HHSI) pump operating on one train.
- d. The SBLOCA total head loss value discussed in the 2009 RAl-34 response is equivalent to the clean strainer head loss of an LBLOCA. The SBLOCA value does not consider debris-induced head loss or the effect of lower velocity on clean strainer head loss (CSHL). The clean strainer head loss value from July 2008 testing is found by applying a temperature correction to the design clean strainer head loss value (CSHL) of 1.952 ft-water [2], splitting out the plenum contribution from this design CSHL value, and adding the plenum contribution to the CSHL value found during the July 2008 strainer testing [1]
- e. The calculation from the 2009 RAl-34 response is repeated at important time points from the most recent revision of the design basis accident analysis calculation of temperature and pressure [3]. The design basis TH analysis resulting in the highest temperature represents a double ended guillotine (DEGB) Hot-Leg break with minimum containment heat removal systems (CHRS), which are described in the bulleted list below.
3 of 6 containment cooler fans operational 2 of 3 containment spray trains operational 2 of 3 LHSI pumps operational during injection 2 of 3 LHSI pumps operation during recirculation 2 of 3 HHSI pumps operation during recirculation, which are secured at 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> post-LOCA in the thermal-hydraulic analysis This modelling is very conservative and does not represent the expected plant state following a LOCA. There is conservatism from the design basis DEGB hot leg break inputs for this degasification analysis. The peak sump temperature occurs around 5-minutes after the start of recirculation. Realistic debris loading at the strainer assuming a homogenously mixed pool would have the total amount of debris arrive much later than 5-minutes.
Realistic debris timing is explored in Case 1 and Case 2 below where only clean strainer head loss is considered at the time of and before the peak temperature conditions.
Calculated values for both the bounding maximum (273.6 °F) and minimum temperature (121 °F) from the design basis DEGB hot leg break calculation are included in the bounding degasification analysis. Resulting degasification of the bounding temperature cases is measured by calculated void fraction (ex), which is the ratio of air release to total water flow rate. The void fraction is dependent on strainer flow rate, pressure loss across the strainer, sump temperature, containment pressure, sump humidity, containment humidity, water level, and height to the middle of the strainer respectively as shown in the
NOC-AE-16003368 Page 4 of 6 functional statement below; where the height to the middle of the strainer is 1.1875 ft and the sump and containment humidity's have been set to unity for all evaluated cases.
a( Qstrainen PLOSS* Tsump* Pcontainment* %Hsump, %Hcontainment* WL, hMidStrainer)
Important parameters for the bounding hot leg break degasification calculation are given in RAl-34 Table 1 and Table 2 below. Note that although accident pressure would be the more accurate pressure to calculate air release/void fraction with, standard methodologies follow the rules in the bulleted list below for degasification calculations.
For temperatures below the 212 F boiling temperature of water, atmospheric pressure (14.7 psi) is used For temperatures above the 212 boiling temperature of water, saturation pressure is used if an acceptable void fraction ( <2%) can be calculated Where saturation pressure does not result in an acceptable calculated void fraction, the smallest pressure above saturation pressure to result in an acceptable calculated void fraction is used. Acceptable is defined as a calculated void fraction less than 2% with non-boiling conditions in the pool. These pressures are denoted with "*" in Table 2.
The rules in the bulleted list above define how the Analyzed Pressure (Column 3 of Table
- 2) is chosen for the degasification cases calculated.
RAl-34 Table 1: Degasification Calculation Inputs from OBA Min Cooling HLB DEGB Scenario Qstrainer Ploss Tsump Accident WL Case Strainer Pressure Temper Analysis.
Saturation Water Accident Time Flow Loss [ft-ature at Containment
.Pressure Level Sump Pressure (psia)
(gpm) water]
[oF)
(psia)
[ft]
1465 sec; 1**
start of 7020 0.497 269.8 43.3 41.7 3.208 recirculation 1756 sec; 2**
Peak sump 7020 0.488 273.6 44.9 44.4 3.208 temperature 3
2001 sec 7020 3.757 266.9 45.6 39.8 3.208 4
2.5 hrs post-7020 4.946 213.6 29.0 15.2 3.208 LOCA 5
24 hrs post-7020 7.994 144.0 18.3 3.2 3.208 LOCA 6
24 hrs post-3550 1.071 144.0 18.3 3.2 2.417 LOCA 7
30 days post-7020 9.780 121.0 16.9 1.7 3.208 LOCA
- ~
- .I
NOC-AE-16003368 Page 5 of 6 Utilizing the standard input in RAl-34 Table 1 as well as the "Analyzed Pressure" column from Table 2, the void fraction is calculated for each condition utilizing the CASA Grande degasification module. Considering failure at the pump occurring from either the pool boiling, or gas voiding exceeding 2% at a SI or CS pump, according to RG 1.82 Rev. 4
[4], it was not possible to pass the higher temperature scenarios analyzed (213.6 °F, 273.6°F, 266.9°F, and 269.8°F) without crediting additional pressure over saturation pressure. The pressure needed to prevent boiling for these high temperature scenarios and result in a void fraction below 2% was found with iterative CASA Grande degasification routine runs for these scenarios. Note that the difference between the analyzed pressure and the saturation pressure and the difference between the analyzed pressure and the accident pressure are displayed in columns 4 and 5 of Table 2, respectively. Column 4, the difference between "Analyzed Pressure" and "Saturation Pressure" quantifies how much additional pressure (over saturation) is needed to result in a passing calculated void fraction where passing is defined as a calculated void fraction less than 2% with non-boiling conditions in the pool. The difference between "Analyzed Pressure" and TH calculated "Accident Analysis Containment Pressure" in Column 5 of Table 2 quantifies margin in pressure associated with what is needed to result in a passing void fraction value and the amount pressure available from accident analysis TH calculations. Results from all runs considering the DEGB hot leg with minimum cooling inputs is given in RAl-34 Table 2.
RAI 34 T bl 2 D a e T
t" R
It C "d.
OBA M" C
I" HLB DEGB S egasI Ica Ion esu s onsI ermg In 00 Ing cenano Pcontainment Difference Difference Case#
Temperature at Analyzed from Sat.
from Accident Void Sump [°F]
Pressure Pressure Analysis Fraction (psia)
(psi)
Pressure (psi) 1 **
269.8
- 41.9 0.2 1.4 0.000 2**
273.6
- 44.5 0.1 0.4 0.000 3
4 5
6 7
266.9
- 41.3 1.5 4.3 0.020 213.6
- 17.5 2.3 11.5 0.019" 144.0 14.7 11.5 3.6 0.004 144.0 14.7 11.5 3.6 0.000 121.0 14.7 13.0 2.2 0.006
- Smallest pressure above saturation pressure credited to achieve passing degasification scenarios
- No debris bed head loss is used for these cases - only clean strainer head loss is considered. These cases occur less than 5 minutes after the start of recirculation so there will be less than a third of a full sump pool volume turnover. Chemical debris is not expected at this early time post-LOCA. Thus there will not be sufficient debris accumulated on the strainer to have an impact on head loss at the time of this case.
RAl-34 Table 2 includes the results of the degasification analysis considering worst case Rovero material loading and the OBA hot leg break scenario temperatures and pressures.
Results for Cases 5, 6 and 7 show that no additional pressure credit was needed to prevent boiling and a void fraction above 2%. Results for high temperature Cases 1, 2, 3, and 4 need additional pressure credit to achieve passable results considering the void fraction limit and boiling conditions in the pool. For Cases 1, 2, 3, and 4 this credit is
NOC-AE-16003368 Page 6 of 6 performed in accordance with RG 1.82 [4], where additional pressure is not credited above what is needed to prevent a failing NPSH value from boiling and forced cavitation due to voiding, and because additional pressure credited results in a cumulative pressure less than the OBA analysis pressure.
- f.
Design basis values for strainer submergence, temperature and strainer flow rates were used to evaluate deaeration in part e. of this RAI response. The evaluation from part e. of this RAl-response for Cases 3, 4, 5, 6, and 7 also utilized total head loss, including the effects of chemicals and clean strainer head loss, from the July 2008 STP strainer head loss test which is the basis for failure in the STP Rovero methodology.
- g. Reabsorption of air is not credited in the analysis performed for part e. of this RAI.
References
[1]
TDl-6005-06 Rev. 3, "Total Head Loss Calculation," March, 2009.
[2]
TDl-6005-05 Rev. 1, "Clean Head Loss - South Texas Project Units 1&2," October, 2006.
[3]
NC-07032 Rev. 19, "Containment LOCA Pressure I Temperature Analysis" January 2015.
[4]
Regulatory Guide 1.82 Rev. 4, "Water Sources for Long-Term Recirculation Cooling Following a Loss-of-Coolant Accident," March, 2012.
Response to SSIB-3-4 through 7 NOC-AE-16003368
5518-3-4 NOC-AE-16003368 Page 1of15 The NRC staff needs additional information to verify how each debris type and size is bounded by the July 2008 test or otherwise accounted for in Rovero.
a)
Please provide an explicit comparison of Rovero transported debris amounts to the 2008 test amounts for each type and size of debris that could be produced in a LOCA event.
Note that some qualified coating types listed as present in containment in Item 3.h, 1 of the Rovero submittal do not appear to be explicitly considered in the Rovero approach (e.g., qualified alkyds and baked enamel).
b)
Please illustrate clearly how each type and size of debris that is predicted to transport to the strainer by Rovero is accounted for in the 2008 test. That is, show which test surrogate was assigned to each Rovero debris type.
c)
The Rovero submittal states that the amount of Microtherm and unqualified epoxy included in the 2008 head loss test was deficient, but excess amounts of Marinite and inorganic zinc (IOZ) address the deficiency. Please explain in detail the basis for the assumption that the Marinite and IOZ account for the debris that was not included in the test. Provide the deficient amount of Microtherm and unqualified epoxy, and the amount and type of each test surrogate that is used to account for the deficient test amounts. The NRC staff has observed that Microtherm (and Min K) has had a significantly larger impact on head loss than Marinite during strainer tests, and Marinite has been observed to have a larger effect on head loss than coatings.
d)
Please show that each debris type predicted by Rovero to transport to the strainer is bounded by the surrogate induded in the 2008 test, using appropriately conservative bounding transport assumptions for each debris size (e.g.,;smalls are maximally transported when considering the Rovero surrogate for smalls but are maximally eroded when considering the Rovero surrogate for fibers).
5TP Response:
As a preface to this RAI response, it should be noted that slight changes were made to the baseline analysis presented in the August 2015 submittal [1]. Minor changes to geometry inputs defining concrete and steel structures were made to support responses to NRC Staff RAls about coatings destruction in this (2016) RAI set. Due to refinements in concrete structures for coatings, which also define robust barriers for debris destruction, small differences were observed in oisman which have been evaluated to have a negligible impact on calculated ~CDF, which is essentially identical to the ~CDF calculated for the August 2015 submittal [1]. In addition to utilizing updated geometry input, all analyses performed in this response are based on the HAL~SE?P baseline which includes other revisions to the August 2015 baseline detailed in the 2016 response to 2009 RAl-19. The HALLSE?P case mode1s all small fiber pieces that reach the pool as settling, in accordance with test observation [2], and erosion of 7% of all settled small fibers into fiber fines.
NOC-AE-16003368 Page 2of15 The August 2015 submittal [1] STP Rovero methodology analyzed two plant states, i.e.
number of trains operable, when considering calculated risk. The plant states analyzed were 2-and 1-trains operable, where the 2-trains operable plant state bounds the failure probability of the 3-trains operable plant state that was not explicitly analyzed. The 2-trains operable plant state was evaluated directly by the July 2008 test [2]; where debris introduced to the test was scaled to the amount that would be apparent on a single module
- if two trains were operating and symmetrically accumulating the same amount of debris.
Because of this, the amount of debris introduced to the July 2008 test can be taken directly as the 2-train operable case failure threshold; where breaks with generated debris that exceed this limit are outside of the test condition and fail. For break scenarios analyzed for the 1-train operable plant state the July 2008 tested Rovero debris limit is divided by two; i.e. it would take half the amount of debris distributed on a single strainer to build a similar composition bed to what would build on two strainers in operation with the same amounts of debris.
Past and updated current analyses have calculated tolerable risk associated with the fine fiber limit defined by the July 2008 introduced fine fiber amounts for both the one and two train operable plant states as well within Risk Region 3 of Reg. Guide 1.17 4 [3]. The comparison of calculated fine fiber generation and' transport to the July 2008 tested amounts of fine fiber, and associated risk calculations are known as Rovero. analysis; where Rovero analysis only refers to risk calculations dependent on fine fiber generation and associated break size. The most recent baseline for the Rovero fine fiber analysis is documented in RAl-19 with case name SR-HALLSE?P and is not transcribed here. The discussion in this RAI will focus on the more recent analysis of generated and transported particulate amounts caused by postulated LOCAs compared to the particulate introduced to the July 2008 test. The difference between calculated, generated and transported particulates and the amounts tested in July 2008 will be referred to as particulate margin throughout.
Particulate margin was assessed only at break locations and sizes considered successful by the fine fiber Rovero analysis. In short this is performed by checking max particulate generation/transport at the critical break locations and sizes (Oismall) as described in -3 of August 2015 submittal [1] as well as OEGB generation at non-critical locations for both the 2-and 1-train plant states. These break specific particulate amounts are compared to the combined particulate, July 2008 test threshold to assess break specific particulate margin; i.e. if particulates are bounded for the passing fine fiber Rovero scenarios.
All 2-train case postulated Rovero LOCA scenarios are bounded by the July 2008 test when considering particulate debris and have positive particulate margin. With respect to the 1-train operability plant state, there are a number of evaluated Rovero LOCA scenarios that have generated and transported particulate amounts that exceed the July 2008 tested debris thresholds, which is one half of the particulate limit for the 2-train operability cases. Full analysis of the amount of particulate margin is performed in the consolidated debris generation report [4].
NOC-AE-16003368 Page 3of15 Negative margin for 1-train cases are caused by amounts of ynqualified coatings debris in excess of the effective 1-train particulate test threshold from the July 2008 strainer test (one-half of the scaled, tested amounts, representative of all transported debris for a 2-train scenario instead transporting to a single strainer). The negative particulate margin for 1-train analysis, which is small for most scenarios, is not expected to further increase the f1GDF value calculated by utilizing the fiber fines Rovero analysis based on a combination of factors:
- 1. A 1-train response to a LOGA is an unlikely response and is analyzed as a beyond design-basis accident scenario.
- 2. For most breaks (especially breaks outside of the reactor cavity) the amount of excess unqualified coatings debris transported to the single operational EGGS strainer is small (less than 1.3 ft3) relative to the total tested debris load. Note that all unqualified coatings outside of the reactor cavity fail immediately as 10
µm particulate and transport at a fraction of 100% for all breaks, regardless of size or location. Although this treatment is consistent with guidance, it is known to be very conservative.
- 3. The 1-train model is formulated such ~hat its probability of occurrence includes many scenarios that may in actuality transport less unqualified coatings debris to a single strainer (e.g. the case of one LHSI pump operating on one strainer and one HHSI pump operating on a second strainer is analyzed as a single train scenario, as the strainer with LHSI pump operating would have a larger flow rate and accumulate a larger amount of debris) [1].
- 4. All 1-train breaks that do not already contribute to the value of f1GDF (i.e.
breaks not already relegated to failure; < Disma
- 11) from the fiber fines Rovero analysis generate and transport less Microtherm debris than the effective.1-*
train Microtherm debris tested amount (one-half of the total, scaled Microther;m amount from the July 2008 strainer test). In this analysis Microtherm is treated as having a one to one head loss effect compared to unqualified coating types.
It is well known that Microtherm is a microporous debris type that often has much larger effects on head loss than other conventional debris.
- 5. The July 2008 strainer test included Marinite board, which would have a larger contribution to strainer head loss than unqualified coatings debris. In this analysis, Marinite is treated as having a one to one head loss effect compared to unqualified coating types. It is well known that Marinite is a microporous debris type that often has much larger effects on head loss than other non-microporous conventional debris types.
- 6. The treatment of chemical debris in the July 2008 test was conservative relative to likely accident scenarios.
- 7. No credit is taken for the amount of tested epoxy chips that were utilized as a test surrogate for 106 lbm of unqualified (i.e. outside ZOI) epoxy coatings. In actuality, some unqualified coatings debris generated in a hypothetical LOGA may be accounted for by this tested debris. There was a clear head loss response to the addition of this debris in the July 2008 test [2].
NOC-AE-16003368 Page 4of15
- 8. No credit is taken for the additional amount of fibrous debris margin available for non-critical welds from the Rovero fiber fines analysis. For many of the non-critical break locations that result in negative particulate margin for the one train case, there is between 20 and 60 lbm of fiber margin available.
- 9. For many of the break locations, the amount of unqualified coatings on large bore piping underneath piping insulation is a key contributor to the amount of excess particulate debris. In the analysis, a conservative amount (one-third, or 0.78 ft3) of this debris is assigned to every break. This assignment of one-third of the total is based on a ZOI that destroys all insulation of large bore piping within a single, full steam generator compartment. Smaller breaks would produce sig~ificantly smaller ZOls, which in turn would destroy significantly smaller amounts of insulation on large bore piping, enabling less unqualified IOZ coatings debris to transport.
- 10. The modeled scenario is reflective of the unqualified coatings present in Unit 1, which is significantly larger than that of Unit 2 (the total unqualified and degraded qualified coatings volume of Unit 1 is 23.95 ft3, while Unit 2 has 15.96 ft3 of unqualified coatings). Evaluation for Unit 2 with reduced unqualified coatings is not performed but would likely result in elimination of negative margin for one train scenarios.
- 11. The amount of latent particulate debris modeled is consistent with regulatory guidance, whereas actual latent particulate amounts may be lower than the generic guidance, as suggested from *plant walkdowns conducted in accordance with NEI 02-01 [1,5].
For these reasons, 1-train strainer particulate margin cases that result in negative margin are not considered in this response and are addressed further in the consolidated debris generation report [4].
a) The statement in Item 3.h, 1 of qualified coatings (QC) in reference 1 of the cover letter, that both alkyd and baked enamel coatings were qualified, is not correct as these coating materials are not qualified. The QC calculations in the 2016 consolidated debris generation report [4], ALION-CAL-STP-9277-01, accurately defines the QC systems present at STP. The entire array of debris types present at STP are provided below in Table 1.
NOC-AE-16003368 Page 5of15 Table 1: Rovero Transported Debris Types and Classifications
, ~r~u~:i,iti~~(;~~~$&;'.f ;A+l Fiber (LDFG fines)
Yes Microtherm Yes IOZ Yes Yes Epoxy Yes Yes Alkyd Yes Baked Enamel Yes Latent Part.
Yes Latent Fiber Yes In order to compare the non-fibrous transported debris amounts to the 2008 test amounts, the Rovero transported amounts must first be clearly defined. The Rovero analysis divides the debris generation scenarios into a passing or a failing category based solely on the transported fine fiber threshold. The failing list of break locations is defined as the critical weld list which includes the smallest break size to fail, oisma 11,
when considering the fiber fine limit and the continuum break mpdel. No greater break size (>Oismall) with associated greater amount of any debris type could impact the overall plant risk from these locations as they have been by definition relegated to failure.
The remaining collection of break locations and sizes, i.e. those which do not reach the Rovero limit of fine fiber transport, are credited for success as the July 2008 tested debris amounts bound the fine fiber amount transported. In addition to bounding the fine fiber debris amount, this response will show that the July 2008 test debris amounts bound all other debris type amounts for this collection of breaks for the 2-train analysis.
Two types of analysis were performed to adequately demonstrate that all transported debris amounts for all debris types are bounded by the July 2008 tested debris amounts. In the August 2015 submittal [1], only fibrous fines and IOZ particulate were investigated on a weld by weld basis. The first type ran a Rovero search to examine each weld location for fine fiber debris transport while postulating breaks over the entire continuum of break size. Each location where a transported debris load of fine fiber reached or exceeded the 2008 tested quantity was added to the critical weld list and marked with the smallest break size to produce a failing debris load, oisma 11
- The second type of analysis preserved the risk quantification from the previous type by analyzing all break sizes at each location which had a passing fibrous debris load (as compared to the July 2008 test). This ensures that particulates are bounded by the July 2008 test for all Rovero breaks/sizes that are considered successful, i.e. will not lead to core damage. This analysis included finding the largest amount of all debris types destroyed and transported for the smallest break size to fail (oismall) at all of the critical weld locations and the OEGB amount of all debris types transported at all of the non-critical welds.
NOC-AE-16003368 Page 6of15 The transported particulate amounts, except Microtherm, were combined for volumetric comparison against the tested loading under the assumption that all analyzed particulate were destroyed as 10 micron particulate. Microtherm was evaluated separately as it is a problematic debris type. Another problematic debris type, Marinite, was included in the July 2008 test loading and is considered an extra particulate term providing margin for the combined 10 µm particulate debris amount.
To be clear, no credit is taken for the Marinite which was added to the test with respect to Microtherm debris quantities; Marinite is only used in this analysis to offset negative margin from non-problematic, conventional particulate debris types. Microtherm is bounded for every successful Rovero scenario so its excess at each location is also considered as an extra particulate margin term for 10 µm particulate.
The results of these analyses are presented in Table 2 which shows that each debris amount generated and transported for passing break sizes/locations is bounded by the July 2008 test. The negative margin for the combined coatings debris group is addressed with the margin in the problematic debris types, Microtherm and Marinite (note that the maximum Rovero transported volumes provided in Table 2 are from different breaks and should not be used to characterize a particular scenario). It is important to reiterate that this data is restricted to 2-train operability states only and that 1-train operability states are not considered in this response.
Table 2: Maximum Rovero Transported Amounts vs. July 2008 Tested Amounts Microtherm 0.959 2.200 1.241 Marinite O*
3.972 3.972 Coatings and Latent Particulate 16.591 11.362
-5.229
- Marinite has been removed from STP containment The ten minimum margin weld locations for particulates are also provided in Table 3.
The consolidated debris generation report [4] contains a complete weld specific margin analysis.
NOC-AE-16003368 Page 7of15 Table 3: Ten lowest 10 µm particulate margin weld locations for 2-train operability
~. jJ,,0:tW.*.*., *
.,.'\\
~. *:*; 'f *,. '\\t.
. \\1' 'Jjj>*r: *.* Y*;
- . ;s.:q :s I:*;s.~ :;.*
- !{* ****1
~*.... :f:.;
)[;'>2~!rai~ ~a~~ MinJm~n*fM~fg~n.'r~ld ~o:~\\icws**~**.. +
.*. '>s\\/'l Margin (ft3)
Weld Location Hot/Cold Break Total Generated Leg Size (in)
Particulate (ft3 )
1 0.65 27.5-RC-1103-NSS-7 Cold 27.5 16.887 2
0.68 27.5-RC-1203-NSS-4 Cold 27.5 16.858 3
0.71 27.5-RC-1103-NSS-6 Cold 27.5 16.826 4
0.74 27.5-RC-1103-NSS-RPV1 -N2ASE Cold 27.5 16.795 5
0.75 27.5-RC-1203-NSS-5 Cold 27.5 16.789 6
0.75 27.5-RC-1303-NSS-5 Cold 27.5 16.783 7
0.76 27.5-RC-1303-NSS-6 Cold 27.5 16.775 8
0.77 27.5-RC-1303-NSS-RPV1 -N2CSE Cold 27.5 16.759 9
0.'19 27.5-RC-1203-NSS-RPV1 -N2BSE Cold 27.5 16.746 10 0.87 29-RC-1301-NSS-1 Hot 15.95
- 15. 710 b) Each individual type and size of transported debris as well as the surrogate used in the July 2008 test is presented in Table 4.
Table 4: Rovero transported debris types, sizes and applicable surrogates j*p~b.ris fype s~q~kris Size SHJ\\to.~~t;;
j Fiber (LDFG)
Fines Nukon/Knauf ET Microtherm 10 µm Problematic Powderized Microtherm IOZ 10 µm Powderized Tin Epoxy 10 µm Powderized Acrylic Alkyd 10 µm Powderized Acrylic Baked Enamel 10 µm Powderized Acrylic Latent Particulate 10 µm PCI Plant Dirt Mix Latent Fiber Fines Nukon/Knauf ET It was visually observed that none of the fibrous smalls transported in the July 2008 test and are therefore not analyzed to transport in the 2016 evaluation. Also added to the July 2008 test were acrylic chips (designed as a surrogate for unqualified epoxy coatings), but their contribution is not analyzed in the current 2016 evaluation (unqualified coatings debris is instead modeled as 10 µm particulate debris for the margin calculation). Degraded, qualified epoxy coatings debris (wholly located within the reactor cavity) is also treated as 10 µm particulate debris for the margin calculation, but with unique transport fractions, as described in the consolidated debris generation report [4].
NOC-AE-16003368 Page 8of15 The only tested debris type considered for margin (as 10 µm particulate debris) but not listed in Table 4 is Marinite board; the July 2008 test utilized powdered Marinite board as the representative test surrogate [2]. Since the test, all Marinite board has been removed from containment.
The remaining debris quantities which were added to the test were entirely comprised of fiber fines and fine particulates. The predicted types of debris which are transported in the Rovero fine fiber and particulate margin analysis are all accounted for by the debris type surrogates utilized in the July 2008 test.
c) The previous analysis provided in the August 2015 submittal was based on 2008 debris generation analysis. To address Staff inquiries regarding the entire inventory of transported debris types in part "a" of this response, all debris destruction analysis was updated with break specific CASA Grande debris generation. In the updated analysis there are no Rovero successful break locations\\sizes that produce amounts of destroyed Microtherm greater than what was tested in July 2008. The complete list of break locations is presented in the consolidated debris generation report [4].
To illustrate the weld-by-weld Microtherm analysis, Table 5 presents the 10 weld locations with the greatest Microtherm debris amounts transported for passing fiber fine Rovero scenarios. All debris amounts are bounded by the July 2008 tested volume of 2.2 ft3 and no credit is taken for excess IOZ or Marinite to bound the Microtherm quantities. These quantities are in fact also capable of passing the 1-train operability limit of 1.1 ft3.
2 3
4 5
6 7
8 9
10 Table 5: 2~ Train Data, 10 Highest Microtherm Producing Welds Margin Weld Location 1.241 29-RC-1201-NSS-4 1.261 29-RC-1101-NSS-4 1.291 29-RC-1201-NSS-5.1 1.295 29-RC-1201-RSG-1 B-IN-SE 1.333 29-RC-1101-NSS-5.1 1.340 29-RC-1101-NSS-RSG-1A-IN-SE 1.386 29-RC-1301-NSS-4 1.386 12-RC-1125-881-7 1.395 12-RC-1221-881-7 1.420 12-RC-1221-881-8 Hot/Cold Leg Hot Hot Hot Hot Hot Hot Hot Cold Cold Cold Break Size (in) 14.4 14.17 15.35 15.33 15.08 15.07 14.41 10.126 10.126 10.126 Total Generated Microtherm (ft3l 0.959 0.939 0.909 0.905 0.867 0.860 0.814 0.814 0.805 0.780 In part "a" of this response, Table 3 lists the 10 welds with the lowest amount of particulate debris margin. The transported debris types/amounts for the break with the lowest 2-train particulate margin (a DEGB at weld 27.5-RC-1103-NSS-7) are provided
NOC-AE-16003368 Page 9of15 along with the July 2008 tested debris amounts corresponding to these Rovero debris types in Table 6 for a more detailed evaluation of the specific debris types.
Fiber Fines 51.843 79.910 Latent Fiber 11.875 Total Fiber 63.718 79.910 Microtherm 0.302 2.200 Qualified IOZ 0.042 3.006 Unqualified IOZ 2.428 Qualified Epoxy 0.000 7.519 Degraded Qualified Epoxy 6.536 Unqualified Epoxy 2.876 Alkyd 0.870 Baked Enamel 2.875 Latent Particulate 0.958 0.837 Marinite Board 3.972 Total Particulate 16.887 17.534
- No credit is taken for tested acrylic chips used as surrogates for unqualified epoxy
- Alkyd and baked enamel debris are tested with the same surrogate as qualified epoxy
- Marinite board has been removed from STP containment d) Part "a" of this response has shown that each debris type predicted to transport to the strainer is bounded by the surrogate included in the 2008 test when considering 2-train operability limits. Appropriately conservative bounding transport assumptions were shown to have been used in the response to SSIB RAl-3. To summarize that response, all debris types were assumed to transport at 100% except for fibrous insulation types and what quantity is transported to inactive cavities.
The 2016 response to 2009 RAl-19 also addresses the transport and erosion of small pieces of fibrous debris to a greater extent than was presented in the 2015 [1] submittal. Lastly, the consolidated debris generation report [4] discusses the specific transport methodologies utilized in more detail than is considered in the preface of this response.
References NOC-AE-16003368 Page 10of15
[1] ML15246A126, "Attachment 1-1 STP Piloted Risk-Informed Approach to Closure for GSl-191 through 1-4 Defense in Depth and Safety Margin," 8/20/2015.
[2] 66-9088089, "South Texas Project Test Report for ECCS Strainer Testing," July, 2008.
[3] Regulatory Guide 1.17 4, "An Approach for Using Probabilistic Risk Assessment in Risk Informed Decisions On Plant-Specific Changes to The Licensing Basis," May, 2011
[4] ALION-CAL-STP-9277-01 Rev. 0, "STP Consolidated Debris Analysis and GSl-191 Risk Assessment," July 2016.
[5] NEI 02-01 Rev.1, "Condition Assessment Guidelines: Debris Sources Inside PWR Containments," September 2002.
5518-3-5 NOC-AE-16003368 Page 11 of 15 Please justify the selection of fiber fines to define the sole failure criterion in Rovero. The 2008 test included fines and larger size fiber debris. Explain why only fine fiber amount should be used as the failure criteria. Please address the 2008 test conditions and findings when performing this evaluation.
5TP Response:
Fiber fines were chosen as the sole failure metric for Rovero because all other fibrous debris sizes from the test do not transport. Although other/larger pieces of fibrous debris are generated besides fiber fines for postulated LOCA scenarios (including intact blankets, small pieces and large pieces), fiber fines are the only fibrous debris size that transports considering bounding transport evaluation [1] and empirical evidence. Specifically, intact large pieces of fibrous debris have been shown to not transport to the STP containment pool floor because of the confining geometry of the STP steam generator compartments, which represent the bounding location/compartment for debris transport [1]. The transport pathways for any debris leaving the steam generator compartment must travel through at least one grating which prohibits intact large fibrous piece debris transport to the pool.
Although there is a portion of intact small pieces that transport to the pool based on transport analysis, these small fiber pieces that make it to the pool floor do not transport to the strainer because of empirical evidence from the July 2008 test [2]. Based on visual observation during the July 2008 test all small debris settled to the flume floor without transporting to the strainer under flow conditions that are representative of postulated worst case LOCA conditions at STP; where flow conditions in the flume*were analyzed with CFO analysis prior to the test [3]. Discussion of the adequacy of the flow metrics used in the July 2008 test are discussed in detail on Page 31 of Attachment 1-5 of the,August 2015 submittal [4].
In summary, all fibrous debris sizes other than fine fiber that affect GSl-191 analysis at STP have been analyzed to be reasonably bounding with destruction and transport analysis when compared to debris amounts introduced to the July 2008 test [2].
References
[1]
ALION-CAL-STP-8511-08 Rev. 3, "Risk-Informed GSl-191 Debris Transport Calculation," June, 2014.
[2]
66-9088089 Rev. 0, "South Texas Project Test Report for ECCS Strainer Testing July 2008," November 2008.
[3]
Alden Research Laboratory LETTER 08-28-2008 Rev. 0,, "Definition of Approach Velocity Averaging Planes South Texas Project Test Flume," November, 2008.
[4]
66-9074541 Rev. 0, "South Texas Project Test Report for ECCS Strainer Performance Testing," February 2008.
5518-3-6 NOC-AE-16003368 Page 12of15 In defining test amounts of epoxy coatings that need to be accounted for in the evaluation, it was assumed that coatings in the reactor cavity would not transport to the strainer. However, welds located inside the reactor cavity may allow unqualified coatings to fail and transport even if not within a zone of influence (ZOI).
a)
Please provide more detail on the technical basis for test amounts, considering breaks inside the reactor cavity.
b)
The Updated Final Safety Analysis Report (UFSAR) markup states that 100 percent of unqualified coatings fail as particulate. Table 16 in Attachment 1 2 states that 2008 pounds of unqualified epoxy were considered to fail as chips during the 2008 test. Please explain how this is accounted for in the evaluation.
c)
Please provide a breakdown of the sizing of the unqualified epoxy outside the reactor cavity, including an explanation of why only 48 percent transports to the strainer.
d)
Please evaluate whether amounts of epoxy particles in the July 2008 tests are truly bounding for cases of breaks inside the reactor cavity.
e)
If the coating amounts from the 2008 test are not bounding, please provide an evaluation of the effects of excess coatings on the evaluation or provide a listing of the surrogates that were included in the test in excess that can be assigned to account for epoxy that may not have been adequately represented in the test.
5TP Response:
a) The technical basis for test amounts is not relevant to this analysis because the test amounts only serve as a threshold of comparison for particulate margin analysis at locations/break sizes shown to pass in Rovero fiber analysis; see 2016 SSIB RAl-4 for more complete descriptions of how particulate margin was calculated. The particulate inventory resulting in acceptable head loss values must be considered bounding as it is proven by experiment. Refined analysis performed following the July 2008 test [1], which fed into the Rovero complimentary particulate margin analysis, produced maximum transported debris quantities.
These maximum quantities are bounded by the test values if they are lower in volume than the tested amounts. No further technical basis is needed for the bounding values from the test other than the preservation of debris margin.
Treatment of unqualified and degraded qualified coatings debris within the reactor cavity is discussed in the consolidated debris generation and analysis calculation, ALION-CAL-STP-9277-01 Rev. 0, for use in the particulate margin analysis [2]. For analysis of particulate margin, these coatings are assumed to fail for breaks within the reactor cavity and contribute to the total transported 10 µm particulate debris source; note that for transport considerations only the degraded qualified reactor cavity coatings are treated as chips.
NOC-AE-16003368 Page 13of15 b) The updated analysis treats all unqualified coatings debris as failing wholly and exclusively as 10 µm particulate. The epoxy coatings located within the reactor cavity are classified as degraded qualified coatings (these are the only coatings with this classification at STP). The degraded, qualified coatings fail based on a size distribution taken from OBA testing of Comanche Peak Unit 1 [3]. This methodology is described in §2.5.2 of the consolidated debris generation and analysis report [2] and results in 48.07% transport of the degraded, qualified debris source to the strainer(s) for breaks in the reactor cavity. The transported debris is evaluated in the calculation of particulate margin as 10 µm particulate [2]. It is also noted that the tested epoxy amounts may not be representative of possible epoxy debris generation. Particulate margin was assessed by considering this debris type and other particulate debris types from the July 2008 test holistically, as detailed in the response to SSIB RAl-4 and the consolidated debris generation calculation [2].
c) All unqualified epoxy outside the reactor cavity fails immediately as 10 µm particulate debris and transports 100% to the strainers in the updated analysis.
d) As stated in part a) of this response, the amounts tested in July 2008 are bounding by the fact that head loss margin was preserved during the test. All debris quantities transported for particulate margin analysis which are lower in volume than the July 2008 tested values are bounded by the test while those that are greater in volume must be evaluated separately. Evaluation of particulate margin for the risk calculated using the Rovero fiber fines methodology is performed in ALION-CAL-STP-9277-01 [2]. This evaluation shows that all breaks (including those within the reactor cavity) that are acceptable breaks in the Rovero fiber fines analysis remain bounded by the July 2008 test for 2-trains of ECCS in operation.
For scenarios with only a single train of ECCS operational, particulate debris loads, especially those for reactor cavity breaks, may exceed tested particulate amounts (depending on the figure of merit utilized, etc.). This is addressed in the preface to SSIB RAl-4.
e) It is agreed that tested quantities of individual debris types may be deficient for some break scenarios. All tested quantities and surrogates are fully defined in the response to SSIB RAl-4, specifically sections "a" and "c" of the response, which discuss a holistic analysis of particulate debris. Additional information is also provided in ALION-CAL-STP-9277-01, which discusses the evaluation in greater detail [2]. In summary of the methodology for particulate margin, breaks that bound all acceptable break sizes from the Rovero fiber fines analysis at every hypothesized break location in containment are analyzed for particulate debris generation and transport. This evaluation considers break specific Microtherm debris generation versus the tested Microtherm debris separately from other debris types, as well as break dependent and independent particulate debris holistically
NOC-AE-16003368 Page 14of15 from all sources (i.e. Microtherm, qualified coatings, unqualified coatings, and latent particulate) versus tested particulate debris. This calculation [2] supports the thesis that the July 2008 test bounds the Microtherm transported by breaks not relegated to failure in the Rovero fiber fines analysis with some amount of excess margin. Additionally, the calculation supports the bounding nature of the July 2008 test for 2-train particulate loads; however, the ALION-CAL-STP-9277-01 calculation alone does not support 1-train particulate loads. Particulate loads for the 1-train scenarios are discussed in the preface of SSIB RAl-4.
References
[1] 66-9088089, "South Texas Project Test Report for ECCS Strainer Testing," July, 2008.
[2] ALION-CAL-STP-9277-01 Rev. 0, "STP Consolidated Debris Analysis and GSl-191 Risk Assessment," July 2016.
[3] ALION-CAL-TXU-4464-02 Rev. 0, "TXU Paint Chip Characterization," October 2007.
SSIB-3-7 NOC-AE-16003368 Page 15of15 LOCA Containment Pressure. Sump Temperature. and Sump Level Response Analysis The response to item 3.g.1 provides the sump temperature for the most recent LOCA containment pressure/temperature analysis performed by the licensee using the computer code GOTH IC. The UFSAR Section 6.2.1.1.3.1, "Containment Pressure and Temperature Analysis," states the LOCA containment pressure and temperature response analysis was performed using the CONTEMPT4/MOD5 computer code. The response to item 3.g.8 describes the methodology used to determine the post-LOCA sump level. In the current analysis in the UFSAR, the outputs of containment analysis for maximum sump temperature response should also include a sump level response.
a) Please explain if the containment pressure, sump temperature, and sump level reported in the August 20, 2015 supplement are consistent with the licensing basis results.
b) There is an STP license amendment request for an extension to the containment integrated leak rate testing from 10 years to 15 years currently under NRC review.
Since this identifies a change from using CONTEMPT to GOTHIC for the licensing basis containment analysis, please explain what licensing basis methodology will be used going forward.
c) Please explain if the change in methodology from CONTEMPT to GOTHIC for the licensing basis LOCA containment analysis will maintain the methodology that results in maximizing the sump temperature and minimizing the sump level for the sump level and temperature response for determining available NPSH.
STP Response a) The description in the August 20, 2015 supplement included a sump temperature and containment pressure that were calculated as part of the LOCA containment pressure and temperature response analysis.
This was performed using the CONTEMPT computer code. The most recent LOCA containment pressure/temperature analysis was performed using the computer code GOTHIC. This resulted in a higher maximum sump temperature which was evaluated not to significantly impact the NPSH evaluation.
b) Going forward, the GOTHIC analysis will be used. This is the current licensing basis analysis and is discussed in Sections 6.2.1.1 and 6.2.1.3 of UFSAR Revision 18.
c) The Gothic containment analysis gives the sump temperature consistent with a containment peak pressure and containment temperature analysis. The analysis that will result in maximizing the sump temperature has not been performed. The change from the use of CONTEMPT to GOTHIC resulted in a higher maximum sump temperature. There was no change to the sump level determination since the increase in sump temperature (and corresponding decrease in sump fluid density) did not have an adverse impact.
Response to STSB-3-1 NOC-AE-16003368
STSB-3-1 NOC-AE-16003368 Page 1 of 2 Paragraph 10 CFR 50.36(c)(2)(i) states, in part, that:
Limiting conditions for operation are the lowest functional capability or performance levels of equipment required for safe operation of the facility. When a limiting condition for operation of a nuclear reactor is not met, the licensee shall shut down the reactor or follow any remedial action permitted by the technical specifications until the condition can be met.
In its second supplement to the LAR for a risk-informed approach to resolving GSl-191, STPNOC proposed the following new condition 'c.' for TS LCO 3/4.5.2, ECCS SUBSYSTEMS - TAVG GREATER THAN OR EQUAL TO 350°F:
- c.
With less than the required flow paths OPERABLE solely due to potential effects of LOCA generated and transported debris that exceeds analyzed amounts, perform the following:
- 1.
Immediately initiate action to implement compensatory actions, AND
- 2.
Within 90 days restore the affected flowpath(s) to OPERABLE
- status, OR Be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
The NRC staff is concerned the 90-day proposed completion time would allow an inappropriate amount of time for certain scenarios. For instance, 90 days appears to be excessive for a scenario where gross blockage of the strainer is evident and it is clear that the ECCS would be incapable of performing its specified safety function (e.g., if tarps were inadvertently left covering the sump screens following an outage).
In other cases (e.g., where an administrative fiber limited is inadvertently exceeded), the 90 days may be appropriate because of conservatisms in the licensing basis analysis.
Most TS completion times are of limited duration, making the consideration of the spectrum of scenarios that could render a structure, system, or component (SSC) inoperable unnecessary.
For long duration completion times, however, such as the 90 days discussed above, the licensee needs to show that the completion time minimizes the level of risk to the public. The NRC staff requests the licensee to provide an explanation of the technical basis for the 90 days, including how any currently established programs, such as the configuration risk management program, would factor into its response to an unlikely, but severe scenario discussed above.
STP Response:
NOC-AE-16003368 Page 2 of 2 A 90-day completion time is reasonable for emergent conditions that involve debris that could be generated and transported under LOCA conditions. The likelihood of an initiating event in the 90-day completion time is very small (1/4 of the LOCA annual frequency).
There are margins in the debris generation and transport analyses and in the downstream and in-core effects analyses. Ninety days is a reasonable time to identify and implement mitigating or compensatory action, such as removing the debris, securing or containing the debris so that it is not transportable, performing additional analysis, or obtaining regulatory relief (e.g., Enforcement Discretion and/or Emergency or Exigent TS change).
The compensatory actions required by proposed Required Action c.1 provide additional assurance that the potential debris effects of the emergent condition would be mitigated.
In addition to the actions directly addressing the debris just mentioned, plant system configuration can be managed by application of the CRMP to maximize availability of mitigating systems (e.g., ECCS, AFW, SDGs) and defense in depth (e.g., containment isolation, CCW, ECW) by limiting activities that remove them from service.
NRC approval of TSTF-448 under the Consolidated Line Item Improvement Process (ML063460558), which revised the TS required action and completion times for Control Room Envelope Ventilation and Filtration System (CREVFS), is precedence for a 90-day completion time with compensatory actions supporting the extended completion time.
STPNOC did not intend the action to apply to conditions such as tarps covering the strainers. Degradation or nonconformances of this kind do not meet the proposed TS condition of "potential effects of LOCA generated and transported debris". The 90-day action would not apply and the appropriate TS action for the affected train(s) should be entered. The excerpt below from the Bases for the proposed TS changes addresses conditions such as this. The markups reinforce the intent.
Applicability This required action applies only for the potential effects of debris on emergency sump strainer operability or on in-core debris effects. It does not apply for effects other than those caused by debris for which the testing and analysis apply.
Debris effects are conditions caused by transportable debris that could impact the net positive suction head or otherwise degrade pump performance, or cause strainer structural failure by excess accumulation on one of more of the emergency sump strainers. Obstructions or covers on the strainers such as tarps,Gaf35 or other conditions that are a physical degraded or nonconforming condition of the strainer (e.g., gaps, deformations) are to be addressed by the system train-specific, non-debris TS actions a and b.
Response to SCVB-3-1 NOC-AE-16003368
SCVB-3-1 NOC-AE-16003368 Page 1of2 The STP UFSAR Section 6.2.1.3, "Mass and Energy Release Analyses for Postulated Loss of Coolant Accidents," states the use of Westinghouse Electric Company, LLC (Westinghouse)
WCAP-10325-P-A methodology for LOCA mass and energy release analysis. Westinghouse has issued Nuclear Safety Advisory Letters (NSALs)-06-6, 5, and 2, and lnfoGram IG-14-1 reporting errors in this methodology. Also a new methodology (GOTHIC) is used for LOCA containment analysis for which the mass and energy input needs to be corrected based' on the above NSALs and the lnfoGram. Please submit the following revised licensing basis containment analysis for NRC review which should include the following: (a) changes, and justification of changes in inputs and assumptions from the current analysis, and (b) results.
a)
LOCA containment mass and energy release analysis.
b)
Pressure and temperature response analysis for containment integrity c)
Peak temperature analysis for equipment environmental qualification (EEQ) d)
Sump temperature and level response for NPSH analysis.
e)
Minimum containment pressure response for ECCS analysis.
STP Response:
For parts a, b, and c of this RAI, see the March 17, 2016, response to a similar RAI on the STPNOC LAR for extension of the Containment Leakage Rate Testing Program (ML16089A406) d)
Sump temperature and level response for NPSH analysis.
RESPONSE: For each break analyzed, two cases are performed. One case is to maximize the Containment pressure and the other is to maximize the Containment temperature. These methods follow the input guidelines for containment pressure and temperature analysis provided in Table 3.6.1 of DOM-NAF-3, "GOTHIC Methodology for Analyzing the Response to Postulated Pipe Ruptures Inside Containment," November 6, 2006 (ML063190467). STPNOC selected the maximum sump temperature using the split heat transfer option as described in Section 3.3.2 of DOM-NAF-3. As noted in the response to SSIB RAl-33, STPNOC has not specifically analyzed the sump temperature using the cited NRC guidance.
The change from the use of CONTEMPT to GOTHIC resulted in a higher maximum sump temperature. There was no change to the sump level determination since the increase in sump temperature (and corresponding decrease in sump fluid density) did not have an adverse impact.
e)
Minimum containment pressure response for EGGS analysis.
NOC-AE-16003368 Page 2 of 2 RESPONSE: The post LOGA minimum containment pressure response for EGCS analysis is performed by Westinghouse. The results are provided in UFSAR Section 6.2.1.5. NSALs 06-6, 11-5, and 4-2 and IG 14-1 pertain to peak pressure and temperature containment analysis. Westinghouse has confirmed that the NSALs and IG do not impact the results presented in UFSAR Section 6.2.1.5.
Definitions and Acronyms NOC-AE-16003368
NOC-AE-16003368 Page 1 of 2 Definitions and Acronyms ANS American Nuclear Society ECCS Emergency Core Cooling ARL Alden Research Laboratory System (also ECC)
ASME American Society of ECWS Essential Cooling Water Mechanical Engineers System (also ECW)
BA Boric Acid EOF Emergency Operations BAP Boric Acid Precipitation Facility BC Branch Connection EOP Emergency Operating BEP Best Efficiency Point Procedure( s)
B-F Bimetallic Welds EPRI Electric Power Research B-J Single Metal Welds Institute BWR Boiling Water Reactor EQ Equipment Qualification CAD Computer Aided Design ESF Engineered Safety Feature CASA Containment Accident FA Fuel Assembly(s)
Stochastic Analysis, also a FHB Fuel Handling Building short name for the CASA GDC General Design Criterion(ia)
Grande computer program GL Generic Letter that uses the analysis GSI Generic Safety Issue methodology HHSI High Head Safety Injection CCDF Complementary Cumulative (ECCS Subsystem)
Distribution Function or HLB Hot Leg Break Conditional Core Damage HTVL High Temperature Vertical Frequency Loop ccw Component Cooling Water HLSO Hot Leg Switchover CDF Core Damage Frequency HVAC Heating, Ventilation & Air CET Core Exit Thermocouple(s)
Conditioning CHLE Corrosion/Head Loss ID Inside Diameter Experiments IGSCC lntergranular Stress CHRS Containment Heat Removal Corrosion Cracking System ISi In-Service Inspection CLB Cold Leg Break or Current IOZ Inorganic Zinc Licensing Basis LAR License Amendment CRMP Configuration Risk Request Management Program LBB Leak Before Break cs Containment Spray LBLOCA Large Break Loss of Coolant CSHL Clean Strainer Head Loss Accident (also LLOCA) css Containment Spray System LCO Limiting Condition for (same as CS)
Operation eves Chemical Volume Control LDFG Low Density Fiberglass System LERF Large Early Release OBA Design Basis Accident Frequency DBD Design Basis Document LHS Latin Hypercube Sampling D&C Design and Construction LHSI Low Head Safety Injection Defects (ECCS Subsystem)
DEGB Double Ended Guillotine LOCA Loss of Coolant Accident Break LOOP/LOSP Loss of Off Site Power DID Defense in Depth MAAP Modular Accident Analysis OM Degradation Mechanism Program
NOC-AE-16003368 Page 2 of 2 Definitions and Acronyms MAB/MEAS Mechanical Auxiliary RMS Records Management Building or Mechanical System Electrical Auxiliary Building RMTS Risk Managed Technical MBLOCA Medium Break Loss of Specifications Coolant Accident (also RVWL(S)
Reactor Vessel Water Level MLOCA)
(System)
NIST National Institute of RWST Refueling Water Storage Standards and Technology Tank NLHS Non-uniform Latin SBLOCA Small Break Loss of Coolant Hypercube Sampling Accident (also SLOCA)
NPSH Net Positive Suction Head, SC Stress Corrosion (NPSHA - available, SI/SIS Safety Injection, Safety NPSHR-required)
Injection System (same as NRC Nuclear Regulatory ECCS)
Commission SIR Safety Injection and NSSS Nuclear Steam Supply Recirculation System SR Surveillance Requirement QBE Operating Basis Earthquake SRM Staff Requirements.
OD Outer Diameter Memorandum OQAP Operations Quality SSE Safe Shutdown Earthquake Assurance Plan STP South Texas Project PCI Performance Contracting, STPEGS South Texas Project Electric Inc.
Generating Station PCT Peak Clad Temperature STPNOC STP Nuclear Operating PDF Probability Density Function Company PRA Probabilistic Risk TAMU Texas A&M University Assessment TF Thermal Fatigue PWR Pressurized Water Reactor TGSCC Transgranular Stress PW ROG Pressurized Water Reactor Corrosion Cracking Owner's Group TS Technical Specification( s)
PWSCC Primary Water Stress TSB Technical Specification Corrosion Cracking Bases QA Quality Assurance TSC Technical Support Center or QDPS Qualified Display Processing Technical Specification System Change RAI Request for Additional TSP Trisodium Phosphate Information UFSAR Updated Final Safety RCB Reactor Containment Analysis Report Building UNM University of New Mexico RCFC Reactor Containment Fan USI Unresolved Safety Issue Cooler UT University of Texas (Austin)
RCS Reactor Coolant System V&V Verification and Validation RG Regulatory Guide VF Vibration Fatigue RHR Residual Heat Removal WCAP Westinghouse Commercial RI-ISi Risk-Informed In-Service Atomic Power Inspection ZOI Zone of Influence RMI Reflective Metal Insulation