PVNGS UPDATED FSAR June 2001 10-i Revision 11 CHAPTER 10 STEAM AND POWER CONVERSION SYSTEM CONTENTS Page 10.1

SUMMARY

DESCRIPTION 10.1-1 10.1.1 DESIGN BASES 10.1-1 10.1.2 SYSTEM DESCRIPTION 10.1-1 10.1.3 SAFETY-RELATED FEATURES 10.1-2 10.1.3.1 Loss of External Electrical Load and/or Turbine Trip 10.1-2 10.1.3.2 Overpressure Protection 10.1-7 10.1.3.3 Loss of Normal Electric Power 10.1-7 10.1.4 TESTS AND INSPECTIONS 10.1-8 10.1.5 INSTRUMENTATION APPLICATIONS 10.1-8 10.2 TURBINE-GENERATOR 10.2-1 10.2.1 DESIGN BASES 10.2-1 10.2.1.1 Safety Design Bases 10.2-1 10.2.1.2 Power Generation Design Bases 10.2-1 10.2.1.3 Codes and Standards 10.2-2 10.

2.2 DESCRIPTION

10.2-2 10.2.2.1 Turbine-Generator Description 10.2-2 10.2.2.2 Turbine-Generator Cycle Description 10.2-3 10.2.2.3 Automatic Controls 10.2-5 10.2.2.4 Turbine Protective Trips 10.2-13 10.2.2.5 Other Protective Systems 10.2-16

PVNGS UPDATED FSAR June 2007 10-ii Revision 14 CONTENTS (cont)

Page 10.2.2.6 Plant Loading and Load Following 10.2-17 10.2.2.7 Inspection and Testing Requirements 10.2-17 10.2.3 TURBINE DISK INTEGRITY 10.2-18 10.2.3.1 Materials Selection 10.2-18 10.2.3.2 Fracture Toughness 10.2-19 10.2.3.3 High-Temperature Properties 10.2-20 10.2.3.4 Turbine Disk Design 10.2-20 10.2.3.5 Preservice Inspection 10.2-22 10.2.3.6 Inservice Inspection 10.2-23 10.2.4 EVALUATION 10.2-24 10.2.4.1 Power Generation 10.2-24 10.2.4.2 CESSAR Interface Evaluation 10.2-25 10.2.5 INSTRUMENTATION APPLICATIONS 10.2-25 10.

2.6 REFERENCES

10.2-29 10.3 MAIN STEAM SUPPLY SYSTEM 10.3-1 10.3.1 DESIGN BASES 10.3-1 10.3.1.1 Safety Design Bases 10.3-1 10.3.1.2 Power Generation Design Basis 10.3-3 10.3.1.3 Environmental Design Bases 10.3-3 10.3.1.4 Codes and Standards 10.3-3 10.3.1.5 CESSAR Interface Requirements 10.3-4 10.

3.2 DESCRIPTION

10.3-4

PVNGS UPDATED FSAR June 2005 10-iii Revision 13 CONTENTS (cont)

Page 10.3.2.1 General Description 10.3-4 10.3.2.2 Component Description 10.3-4 10.3.2.3 Radiological Considerations 10.3-15 10.3.3 EVALUATION 10.3-15 10.3.3.1 Safety Evaluation 10.3-15 10.3.3.2 CESSAR Interface Evaluation 10.3-20 10.3.4 INSPECTION AND TESTING REQUIREMENTS 10.3-20 10.3.5 WATER CHEMISTRY (PWR) 10.3-20 10.3.5.1 Chemistry Control Basis 10.3-20 10.3.5.2 Corrosion Control Effectiveness 10.3-24 10.3.5.3 Chemistry Control Effects on Iodine Partitioning 10.3-26 10.3.6 STEAM AND FEEDWATER SYSTEM MATERIALS 10.3-26 10.3.6.1 Fracture Toughness 10.3-26 10.3.6.2 Material Selection and Fabrication 10.3-27 10.

3.7 REFERENCES

10.3-29 10.4 OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM 10.4-1 10.4.1 MAIN CONDENSER 10.4-1 10.4.1.1 Design Bases 10.4-1 10.4.1.2

System Description

10.4-2 10.4.1.3 Safety Evaluation 10.4-8 10.4.1.4 Tests and Inspections 10.4-8

PVNGS UPDATED FSAR June 2005 10-iv Revision 13 CONTENTS (cont)

Page 10.4.1.5 Instrument Application 10.4-8 10.4.2 MAIN CONDENSER EVACUATION SYSTEM 10.4-9 10.4.2.1 Design Bases 10.4-9 10.4.2.2

System Description

10.4-10 10.4.2.3 Safety Evaluation 10.4-12 10.4.2.4 Tests and Inspections 10.4-12 10.4.2.5 Instrumentation Applications 10.4-13 10.4.3 TURBINE GLAND SEALING SYSTEM 10.4-13 10.4.3.1 Design Bases 10.4-13 10.4.3.2

System Description

10.4-14 10.4.3.3 Safety Evaluation 10.4-15 10.4.3.4 Tests and Inspection 10.4-15 10.4.3.5 Instrumentation Applications 10.4-16 10.4.4 TURBINE BYPASS SYSTEM 10.4-16 10.4.4.1 Design Bases 10.4-16 10.4.4.2

System Description

10.4-18 10.4.4.3 Tests and Inspections 10.4-20 10.4.4.4 Instrumentation Applications 10.4-20 10.4.4.5 CESSAR Interface Requirements 10.4-21 10.4.4.6 CESSAR Interface Evaluation 10.4-21 10.4.5 CIRCULATING WATER SYSTEM 10.4-21 10.4.5.1 Design Bases 10.4-21

PVNGS UPDATED FSAR June 2007 10-v Revision 14 CONTENTS (cont)

Page 10.4.5.2

System Description

10.4-22 10.4.5.3 Tests and Inspections 10.4-27 10.4.5.4 Instrumentation Application 10.4-27 10.4.6 CONDENSATE CLEANUP SYSTEM 10.4-27 10.4.6.1 Design Bases 10.4-29 10.4.6.2 System Description and Operation 10.4-30 10.4.6.3 Safety Evaluation 10.4-38 10.4.6.4 Tests and Inspections 10.4-39 10.4.6.5 Instrumentation Requirements 10.4-39 10.4.7 CONDENSATE AND FEEDWATER SYSTEM 10.4-40 10.4.7.1 Design Bases 10.4-40 10.4.7.2

System Description

10.4-42 10.4.7.3 Safety Evaluation 10.4-49 10.4.7.4 Tests and Inspections 10.4-50 10.4.7.5 Instrumentation Applications 10.4-51 10.4.8 STEAM GENERATOR BLOWDOWN SYSTEM 10.4-52 10.4.8.1 CESSAR Interface Requirements 10.4-52 10.4.8.2 CESSAR Interface Evaluations 10.4-52 10.4.9 AUXILIARY FEEDWATER SYSTEM 10.4-53 10.4.9.1 Design Bases 10.4-53 10.4.9.2

System Description

10.4-59 10.4.9.3 Safety Evaluation 10.4-64

PVNGS UPDATED FSAR June 2007 10-vi Revision 14 CONTENTS (cont)

Page 10.4.9.4 Inspection and Testing Requirements 10.4-76 10.4.9.5 Instrumentation Requirements 10.4-77 APPENDIX 10A RESPONSES TO NRC REQUESTS FOR INFORMATION APPENDIX 10B DELETED

PVNGS UPDATED FSAR June 2007 10-vii Revision 14 TABLES Page 10.1-1 Steam and Power Conversion System Design and Performance Specifications 10.1-3 10.2-1 Turbine-Generator Design Data 10.2-3 10.2-2 Turbine-Generator Performance Data 10.2-4 10.2-3 Turbine Overspeed Sensors and Trip Setpoints 10.2-11 10.3-1 Main Steam Supply System Design Data 10.3-6 10.3-2 Main Steam Isolation Valve Expected Leakage 10.3-8 10.3-3 Flow Paths Originating at Main Steam Lines 10.3-11 10.3-4 Main Steam System Failure Mode and Effects Analysis 10.3-16 10.4-1 Main Condenser Design Data 10.4-4 10.4-2 Condenser Air Removal and Treatment System Design Data 10.4-11 10.4-3 Turbine Gland Sealing System 10.4-15 10.4-4 Circulating Water System Design Data for One Turbine Unit 10.4-24 10.4-5 Main Feedwater/Condensate System Require-ments for Major Components Design Data 10.4-45 10.4-6 Auxiliary Feedwater System Design Data 10.4-62

PVNGS UPDATED FSAR June 2007 10-viii Revision 14 TABLES (cont)

Page 10.4-7 Seismic Category I Valves in Major Flow Paths for the Auxiliary Feedwater System 10.4-67 10.4-8 Single Failure Mode Analysis--Auxiliary Feedwater System 10.4-72

PVNGS UPDATED FSAR June 2003 10-ix Revision 12 FIGURES 10.1-1 Process Flow Diagram Steam and Power Conversion System 10.1-2 Heat Balance at Guaranteed Power 10.1-3 Heat Balance at Stretch (VWO) Power 10.2-1 Overspeed Trip Simplified Logic Diagram 10.2-2 Turbine Protective Trips Block Diagram 10.2-3 Sequential Tripping Logic 10.4-1 Turbine Bypass System

This page intentionally blank

PVNGS UPDATED FSAR June 2001 10.1-1 Revision 11

10. STEAM AND POWER CONVERSION SYSTEM 10.1

SUMMARY

DESCRIPTION The steam and power conversion systems for each unit at PVNGS are identical. Therefore, the summary description provided in this section is on a per-unit basis.

10.1.1 DESIGN BASES The steam and power conversion system is designed to remove heat energy from the reactor coolant in two steam generators and to convert it to electric power via the turbine-generator. The main condenser transfers heat that is not utilized in the cycle to the circulating water system and deaerates the condensate. The closed regenerative turbine cycle heats the condensate and returns it as feedwater to the steam generators.

A full-flow condensate demineralizer system is available to maintain feedwater quality. A blowdown system operates to maintain steam generator water chemistry. The condenser air removal system provides a filter and charcoal adsorber and is monitored for radioactive contamination. The Seismic Category I redundant auxiliary feedwater pumps, one motor-driven and one steam turbine-driven, provide feedwater during loss of offsite power and during design basis accident conditions. A non-Seismic Category I, motor-driven auxiliary feedwater pump provides feedwater for startup, hot standby, and normal shutdown.

10.1.2 SYSTEM DESCRIPTION Components of the steam and power conversion system are of types that have been extensively used in fossil fuel plants and in other nuclear power plants. Instruments, controls, and protective

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2005 10.1-2 Revision 13 devices are provided to ensure reliable and safe operation, as described in paragraph 10.2.2.3.

A system flow diagram is shown in figure 10.1-1. A summary of design basis information and performance specifications is given in table 10.1-1. Also, the cycle heat balances, at turbine rated (guaranteed) power and at stretch power (valves wide open-VWO), are shown on figures 10.1-2 and 10.1-3, respectively, and are summarized in table 10.2-2. Safety-related components include the main steam isolation valves, the atmospheric steam dump valves, the feedwater isolation valves, the Seismic Category I portion of the auxiliary feedwater system, and the main steam safety valves. The steam and power conversion system provides steam for the feedwater pump turbines, the turbine gland sealing system, condensate and feedwater heating, and main turbine reheat steam as required.

The condenser air removal system is described in subsection 10.4.2.

The condensate cleanup system is described in subsection 10.4.6.

The auxiliary feedwater system is described in subsection 10.4.9.

10.1.3 SAFETY-RELATED FEATURES 10.1.3.1 Loss of External Electrical Load and/or Turbine Trip Upon loss of load the turbine control system provides for fast closing of turbine valves. Depending on the magnitude of the load reduction, a turbine bypass system will dump excess steam into the condenser and, if required, to atmosphere. If the load reduction is large, i.e., greater than approximately 55% of full load, an automatic reactor power cutback will be initiated provided the turbine power level is greater than 75%. The turbine control and bypass equipment is not safety grade.

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2007 10.1-3 Revision 14 Table 10.1-1 STEAM AND POWER CONVERSION SYSTEM DESIGN AND PERFORMANCE SPECIFICATIONS (Sheet 1 of 4)

Design and Performance Characteristics Original Design Value (1)

Power Uprate/Rotor Replacement Value (2)

Main steam system minimum required design pressure/temperature, psia/F 1270/575 1270/575 Main steam system operating pressure/

temperature, at 100% power, psia/F (at guar. load 3817/3990 MWt) 1070/552.9 1012/546.1 Main steam system operating pressure/

temperature, at 100% power, psia/F (VWO) 1000/544.6 1007/545.4 Main steam flow, guar./VWO, 10 6 lb/h 17.2/18.1 17.96/18.36 Main turbine throttle flow, guar./VWO, 10 6 lb/h 15.9/17.05 16.87/17.28 Main condenser pressure, in.Hg abs 3.5 3.5 Feedwater temperature, guar./VWO, F 442.5/449.5 448.5/450.9 Main turbine-generator output, guar./VWO, MWe 1304/1375 1411/1443 Guaranteed generator rating, MVA 1559.1 1559.1 No./normal capacity/runout capacity at 65% of each feedwater pump, lb/hr x 10 6 at VWO 2/9.2/11.3 2/9.2/11.3 No./design capacity/runout capacity of each condensate pump, lb/hr x 10 6

3/4.4/6.2 3/4.4/6.2 Turbine gland seal system, normal flow air/steam, lb/h 2855/9025 2855/9025 Steam generator blowdown system, flowrate, normal/abnormal/high rate 0.2%/1%/8% of maximum steam rate 0.2%/1%/8% of maximum steam rate

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2001 10.1-4 Revision 11 Table 10.1-1 STEAM AND POWER CONVERSION SYSTEM DESIGN AND PERFORMANCE SPECIFICATIONS (Sheet 2 of 4)

System Component Performance Characteristics Main steam system (section 10.3)

Main steam piping From each steam generator up to and including the main steam isolation valves:

ASME III, Code Class 2. (design pressure 1255 psig, design temperature 600F, Seismic Category I)

Balance of the main steam piping:

ANSI B31.1 Main steam isolation valves (one per steam line)

Maximum closing time 4.6 seconds after receipt of signal. ASME III, Code Class 2 valves. (design pressure 1270 psia, design temperature 575F, Seismic Category I)

Main steam safety valves (five per steam line)

Required flow capacity equal to 19 x 10 6

lb/hr (105% of the maximum calculated steam generator stretch power flow 18.0 x 10 6

lb/hr) at setpoint pressure: ASME III, Code Class 2 valves. (design pressure 1375 psig, design temperature 575F, Seismic Category I) (See CESSAR Table 5.4.13-2).

Atmospheric dump valves (one per steam line)

Required flow capacity equal to 950,000 lb/hr (min): ASME III, Code Class 2 valves. (design pressure 1333 psia, design temperature 575F, Seismic Category I)

Turbine bypass system (subsection 10.4.4)

Bypass valves down-stream of main steam isolation valves (six piped to condenser, two piped to atmosphere)

Flow capacity equal to at least 55% of design steam flow: Piping ANSI B31.1 (design pressure 1255 psig, design temperature 600F, non-Seismic Category I)

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2001 10.1-5 Revision 11 Table 10.1-1 STEAM AND POWER CONVERSION SYSTEM DESIGN AND PERFORMANCE SPECIFICATIONS (Sheet 3 of 4)

System Component Performance Characteristics Condenser See subsection 10.4.1 Condenser air removal system See subsection 10.4.2 Circulating water system See subsection 10.4.5 Turbine gland seal system See subsection 10.4.3 Condensate and main feedwater system (subsection 10.4.7)

Piping in main steam support structure (MSSS) to upstream economizer feedwater isolation valves - ASME III, Code Class 2.

Design pressure 1875 psig, 450F downcomer feedwater piping to upstream isolation valve - ANSI B31.1, design pressure - 1600 psig, design temperature - 450F. From downstream feedwater isolation valves to steam generators - ASME III, Code Class 2.

Design pressure 1255 psig, 600F, Seismic Category I.

Balance of system piping: ANSI B31.1 Auxiliary feedwater system (subsection 10.4.9)

See subsection 10.4.9.

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2007 10.1-6 Revision 14 Table 10.1-1 STEAM AND POWER CONVERSION SYSTEM DESIGN AND PERFORMANCE SPECIFICATIONS (Sheet 4 of 4)

System Component Performance Characteristics All piping from the condensate storage tank to the Seismic Category I auxiliary feedwater pumps and containment isolation valves is ASME III, Code Class 3; piping from and including the isolation valves to the steam generators is ASME III, Code Class 2, design pressure 1255 psig, design temperature 600F, Seismic Category I All piping associated with the non-Seismic Category I motor-driven auxiliary feedwater pump, excluding upstream of the condensate tank isolation valve and downstream of the containment isolation valves, is ANSI B31.1 Code for pressure piping.

Secondary chemistry control system (subsection 10.4.6)

Full flow condensate demineralization.

Continuous hydrazine additions for oxygen scavenging and continuous ammonia additions for pH control. Continuous monitoring of significant chemical parameters. Steam generator blowdown at a rate up to 8% of the maximum steaming rate NOTE 1:

The parameters listed in Table 10.1-1 for Original Design are nominal parameters obtained from GE Heat Balance 449HB673 (13-M400-0301-00029) and Specification 13-MM-0004/010 for the original rated performance at 3800 MWt and VWO conditions of the plant secondary system, respectively. The Heat Balance and specification are applicable for original operation, stretch power to 3876 MWe and Thot Reduction. For the actual design parameters and predicted performance at various power levels see calculation 13-MC-MT-0200.

NOTE 2:

The parameters listed in Table 10.1-1 for Power Uprate are nominal parameters obtained from GE Thermal Kit 91LR0297 (13-M400-0303-01570) to determine the effect of Replacement Steam Generators, Power Uprate to 3990 MWt and Low Pressure Turbine Rotor Replacement on the plant secondary system. For the actual design parameters and predicted performance at various power levels see calculation 13-MC-MT-0200.

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2005 10.1-7 Revision 13 In the event the condenser is not available to receive steam, ASME Code safety and atmospheric dump valves are provided on the main steam piping.

The atmospheric dump valves are remotely operated from the control room and can be modulated to control the steam flow.

The turbine control system is capable of controlling the speed of the turbine generator upon full load rejection so as not to activate the overspeed trip of the emergency governor system.

10.1.3.2 Overpressure Protection Safety valves are provided on the main steam lines in accordance with the ASME Boiler and Pressure Vessel Code,Section III. The pressure relief capacity of all safety valves is such that the flow capacity is equal to 19 x 10 6 lb/hr (105% of maximum calculated steam generator stretch power mass flow, 18.0 x 10 6 lb/hr) at setpoint pressure.

10.1.3.3 Loss of Normal Electric Power The auxiliary feedwater system is designed to provide feedwater to the steam generators for the removal of decay heat when the feedwater pumps are not available following a loss of normal electric power. In the event of reactor trip with loss of offsite power, two Seismic Category I auxiliary feedwater pumps, one motor-driven and one steam turbine-driven, are available to provide feedwater to the steam generators. The motor-driven pump and its associated isolation valves receive power from a separate standby diesel generator bus. In addition, the steam turbine-driven auxiliary feedwater pump with dc powered controls is available.

Refer to subsection 10.4.9.

PVNGS UPDATED FSAR

SUMMARY

DESCRIPTION June 2001 10.1-8 Revision 11 10.1.4 TESTS AND INSPECTIONS Pumps and controls are given preoperational tests. Functional operational checks are made on essential valves, control systems, and protective equipment.

10.1.5 INSTRUMENTATION APPLICATIONS Operating instrumentation is provided to permit the operators to monitor equipment and plant performance. Equipment, instruments, and controls are inspected regularly and are monitored during operation to ensure proper functioning of systems.

Checking and recalibration of instruments and controls continue during operating periods as well as during standby and shutdown periods.

PVNGS UPDATED FSAR June 2001 10.2-1 Revision 11 10.2 TURBINE-GENERATOR The function of the turbine-generator is to convert thermal energy into electric power.

10.2.1 DESIGN BASES 10.2.1.1 Safety Design Bases The turbine-generator serves no safety function and has no safety design bases.

10.2.1.2 Power Generation Design Bases The following is a list of the principal design bases:

A.

The turbine-generator load change characteristics are compatible with the restrictions imposed by or on the nuclear steam supply system (NSSS). The NSSS is capable of accepting a step load change of 10% and ramp load change of 5% per minute over the load range of 15 to 100%. These load change rates can be accomplished without the operation of the turbine bypass system (TBS) described in subsection 10.4.4. With operation of the TBS, the reactor can accept step load rejections of up to 55% of the rated power of 3817 MWt without causing a reactor trip by bypassing steam to the condenser and, if required, to atmosphere. With the reactor power cutback system and TBS, the reactor can accept a step load rejection of 100% without causing a reactor trip. However, the steam bypass control system (SBCS) and reactor power cutback system (RPCS) are not capable of handling step load rejections for turbine power level between 57% and 75% due to limitations on condenser pressure.

B.

The turbine-generator is designed to trip automatically under abnormal conditions as designated in paragraph 10.2.2.4.

PVNGS UPDATED FSAR June 2003 10.2-2 Revision 12 C.

The turbine-generator is intended to operate base loaded.

10.2.1.3 Codes and Standards System components are designed in accordance with the requirements of ANSI B31.1.0 Code for pressure piping, TEMA and HEI standards for heat exchangers, NEMA standards, IEEE standards, Hydraulic Institute standards, and regulations of the National Board of Fire Underwriters.

10.

2.2 DESCRIPTION

The General Electric turbine-generator (engineering drawings 01, 02, 03-M-MTP-001, -002 and -003) is designated TC6F-43 and consists of turbines, a generator, moisture separator-reheaters, exciter, controls, and auxiliary subsystems. The major design parameters of the turbine-generator are presented in tables 10.2-1 and 10.2-2. Details of system components are presented in this section. The location of the turbine-generator is shown in engineering drawings 13-P-OOB-002 through

-011.

10.2.2.1 Turbine-Generator Description The turbine is an 1800 revolutions per minute, tandem-compound, six-flow, reheat unit with 43-inch, last-stage buckets (blades). The turbine includes one double-flow, high-pressure turbine; three double-flow, low-pressure turbines; and four moisture separator-reheaters with two stages of reheating. The direct-driven generator is conductor-cooled and rated at 1559.1 MVA at 24 kV, three phase, 60 Hz. Other related system components include a complete turbine-generator bearing lubrication oil system, an electrohydraulic control (EHC)

PVNGS UPDATED FSAR TURBINE GENERATOR June 2001 10.2-3 Revision 11 system with supervisory instrumentation, a turbine gland sealing system (refer to subsection 10.4.3), overspeed protective devices, turning gear, a generator hydrogen and seal oil system, a stator cooling system, an exciter cooler, a rectifier section, and a voltage adjuster.

Table 10.2-1 TURBINE-GENERATOR DESIGN DATA Supplier General Electric Unit designation TC6F-43" LSB Last-stage bucket length, in.

43 Design condenser backpressure (average for three shells), in. Hg abs 3.50 Stages of reheating 2

Stages of feedwater heating 7

Rotational speed, r/min 1,800 Guaranteed generator rating, MVA 1,559.1 Generator voltage, kV 24 Power factor 0.9 Short circuit ratio 0.5 10.2.2.2 Turbine-Generator Cycle Description Steam from the main steam system enters the high-pressure turbine through four stop and governing control valves.

Crossties are provided both upstream and downstream of the stop valves to provide pressure equalization with one or more stop valves closed. A portion of the main steam is used for second-stage reheat of the steam supply to the low-pressure turbines.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-4 Revision 14 There are two steam extraction points in the high-pressure turbine. Steam from the first (higher pressure) extraction point is used for seventh-point feedwater heating and first-stage reheat of the two-stage reheater. Steam from the second extraction point is used for sixth-point feedwater heating.

(Refer to subsection 10.4.7 for discussion of the condensate and feedwater system.) After expansion in the high-pressure turbine, the steam flows through the moisture separator-reheaters to remove entrained moisture and to superheat the steam, thus improving cycle efficiency. A portion of the cold reheat steam is used for fifth-point feedwater heating.

(Feedwater heaters are numbered sequentially in order of increasing extraction pressure.)

Table 10.2-2 TURBINE-GENERATOR PERFORMANCE DATA Parameter Guaranteed Load (a)(b)

Original/Pur

& Rotor Replacement Valves Wide Open (a)(b)

Original/Pur &

Rotor Replacement NSSS thermal output, MWt 3,911/4,013 4,030/4,030 Steam generator outlet pressure, psia 1,020/1,030 1,010/1,025 Throttle pressure, psia 1,002/1,012 993/1,007 Throttle temperature, °F 544.8/546.1 543.7/545.4 Main steam flow, 10 6 lb/h 17.5/17.96 18.1/18.36 Gross electrical output, MWe 1,333/1,411 1,375/1,443

a. For turbine-generator design purposes only.
b. The parameters listed for Original Design are nominal parameters obtained from GE Heat Balance for the original rated performance and Valves Wide Open conditions of the plant secondary system. This data is applicable for original operation at 3800 MWt, stretch power to 3876 MWe and Thot reduction. The parameters

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-5 Revision 13 listed for Power Uprate (PUR) are nominal secondary system parameters based upon implementation of Replacement Steam Generators, Power Uprate to 3990 MWt and Low Pressure Turbine Rotor Replacement.

Hot reheat steam leaving the moisture separator-reheaters is used to power the feedwater pump turbine. Hot reheat steam also is distributed equally to the three low-pressure turbines through combined reheat stop and intercept valves. In each low-pressure turbine, there are four steam extraction points for the remaining four stages of feedwater heating (one heater train per low-pressure turbine). After expansion in the low-pressure turbines, the steam is discharged to the main condensers.

In addition to the external moisture separators, the last three low-pressure turbine stages are designed to remove any condensed moisture and drain it to the next lowest extraction.

The moisture from the external moisture separators is drained to moisture separator drain tanks and from there to the high-pressure heater drain tank and subsequently is pumped into the feedwater system. Similarly, the condensate in the reheaters is drained to the heater drain tank and is pumped into the feedwater system.

10.2.2.3 Automatic Controls Automatic controls provide control of turbine speed and acceleration through the entire speed range, with several discrete speed and acceleration rate settings. The automatic control system includes control of load and loading rate from no load to full load, with continuous load adjustments and discrete loading rates. Should it become necessary to remove the generating unit from the primary automatic controls, the

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-6 Revision 13 standby manual control of speed and load takes over, thus allowing continued operation of the turbine generator.

10.2.2.3.1 Electrohydraulic Control Systems The turbine-generator is equipped with an EHC system that combines the principles of solid-state electronics and high-pressure hydraulics to control steam flow through the turbine. The control system has three major subsystems: speed control unit, load control unit, and valve flow control units.

10.2.2.3.1.1 Speed Control Unit. The speed control unit produces the speed error signal for input to the load control unit. This error signal is determined by comparing the desired speed with the actual speed of the turbine at steady-state conditions, or the desired acceleration with the actual acceleration during startup. Because of the importance in safeguarding against overspeed, the speed control unit has two redundant channels. If the primary channel fails, the backup channel takes over automatically. If both channels should fail, the turbine-generator will trip.

The above two speed channels generate three error signals during the period between turbine roll and synchronization.

Two of these error signals are from a deviation between the actual speed as measured by the primary and backup speed sensors and a reference speed. The third error signal is a deviation between the actual acceleration as measured by the primary and backup speed sensors and a reference acceleration.

These signals combine with signals from the load control unit to generate a flow reference signal to the control valves and intercept valves.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-7 Revision 13 10.2.2.3.1.2 Load Control Unit. The load control unit develops flow reference signals that are used to proportion the steam flow to the control valves and intercept valves. Signal outputs are based on a proper combination of the speed error signals and load reference signals. The generator does not strictly follow load, but is controlled through a ramped, predetermined straight-line function. Power/load imbalance is discussed in paragraph 10.2.2.3.1.4.

10.2.2.3.1.3 Valve Flow Control Units. The valve flow control unit regulates the steam flows as directed by the load control unit. Compensation circuits are introduced to ensure linear steam flow response with respect to steam flow reference signals. The bypass valve in the No. 2 main stop valve, control valves, and the intercept valves each have a control loop which consists of electronic circuitry, an electrohydraulic servo valve, a hydraulic actuator, and a linear position transducer. By use of valve position feedback control, the valve control units position the bypass valve in the No. 2 main stop valve, the control valves, and the intercept valves according to the flow demand signal from the load control unit, the standby control unit, or directly from the control panel (valve test).

Only the No. 2 main stop valve has an internal bypass valve.

The control loop operates the internal bypass valve and is used only for prewarming the turbine.

The flow of the main steam entering the high-pressure turbine is controlled by four stop valves and four governing control valves. Each stop valve is controlled by an electrohydraulic actuator so that the stop valve is either fully open or fully closed. The function of the stop valves is to shut off the

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-8 Revision 13 flow of steam to the turbine, when required. The stop valves are closed within 0.2 second or less when steam pressure is present, and are closed in 0.3 second or less when no steam pressure is present, by actuation of the emergency trip system devices. These devices are independent of the electronic flow control unit (see paragraph 10.2.2.3.1.5).

The turbine control valves are positioned by electrohydraulic servo-actuators in response to signals from their respective flow control unit. The flow control unit signal positions the control valves for long range speed control through the normal turbine operating range and for load control after the turbine-generator unit is synchronized.

The combined reheat valves located in the hot reheat lines are stop and intercept valves in one casing and control steam flow to the low-pressure turbines. During normal operation of the turbine, the stop and intercept valves are wide open. The intercept valve flow control unit positions the valve during startup and normal operations and closes the valve rapidly on loss of turbine load. The reheat stop valves close completely on turbine overspeed and trip.

10.2.2.3.1.4 Power/Load Unbalance. Associated with the load control unit is a rate sensitive power/load unbalance circuit whose purpose is to initiate control valve fast closing action under load rejection conditions that might lead to rapid rotor acceleration and consequent overspeed.

Valve action will occur when the power exceeds the load by at least 40% and generator current is lost in a time span of 35 ms or less with an additional 150 ms time delay. Cold reheat pressure is used as a measure of power, and generator current is

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-9 Revision 13 used as a measure of load to provide discrimination between loss of load incidents and occurrences of electric system faults.

The power/load unbalance circuitry includes an approximate 150 ms time delay between the detection of a power/load unbalance condition and actuation of turbine control. This time delay will allow the turbine control to ride out transient electrical grid disturbances. The 150 ms delay is based on a three-phase bolted fault a PVNGS 525 kv switchyard as a worst case scenario.

Following the detection of a power/load unbalance condition and the 150 ms time delay, all control valves are closed in 0.2 second or less when steam pressure is present, and are closed in 0.3 second or less when no steam pressure is present, by a fast acting solenoid for each control valve. Simultaneously, the load reference signal is grounded and the load reference motor begins to run back toward the no-load flow point. Should the condition disappear quickly, the power/load unbalance circuit will reset automatically, and the load reference signal will be reestablished near its value prior to the loss of load. Should the condition persist and the load does not return within approximately 45 seconds, the load reference runback will be completed. The power/load unbalance circuit will clear automatically when the cold reheat pressure drops below 40%.

However, after a power/load unbalance circuit actuation, a positive turbine trip occurs with no subsequent re-opening of the control valves and intercept valves.

10.2.2.3.1.5 Overspeed Protection. Two means of overspeed trip protection are provided; a mechanical overspeed trip (OST) and a backup overspeed trip (BOST). The OST is a conventional eccentric ring that actuates a trip latch to operate a pilot valve that operates the mechanical trip valve. The mechanical

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-10 Revision 13 trip valve releases the hydraulic fluid pressure in the steam valve actuator, allowing the springs to close the steam valves.

The OST trip is set at 110% of rated turbine speed. (Refer to protection system block diagram, figure 10.2-2.)

The BOST is an electric trip normally set to operate at a slightly higher speed than the OST. Three independent BOSTs are provided by magnetic pickups from toothed wheels on the turbine shaft. The signals are amplified through electronic circuitry and are compared to trip speed reference voltage signals.

Exceeding the trip speed will cause each BOST voltage to energize its master trip relay. The master trip relays, through a two-out-of-three logic, deenergize both pilot solenoids of the master (electric) trip solenoid valve. This releases the hydraulic fluid pressure in the steam valve actuators, causing the turbine main valves to close. The overspeed trip logic is shown in figure 10.2-1.

The BOST electric trip also results in a "cross trip" by actuating, also through two-out-of-three relay logic, the mechanical trip, the mechanical trip solenoid, and the trip latch system described above. The BOST trip is set at 111% of rated turbine speed.

When in the standby mode, the automatic speed control and load control subsystems are out of service. If it is necessary to operate the turbine in the standby mode, added overspeed protection is provided by automatically lowering the setpoint of the backup overspeed governor to 105% of rated turbine speed.

The mechanical governor then becomes the backup governor since its trip setpoint remains at 110% of rated speed. (See table 10.2-3 for turbine overspeed sensors and trip signals.)

Each of the two means of overspeed tripping may be independently tested online at any desired load. During these tests,

Table 10.2-3 TURBINE OVERSPEED SENSORS AND TRIP SETPOINTS (Sheet 1 of 2)

Setpoints in Percent of Turbine Rated Speed Sensors Type Function HP Stop Valve HP Throttle Valve LP Stop Valve LP Intercept Valve MTNST-160 Magnetic pickup Normal speed control and overspeed protection None 100 None 102 MTNST-161 Magnetic pickup Normal speed control and overspeed protection None 100 None 102 MTNZS-145 Mechanical eccentric ring Emergency overspeed protection 110 110 110 110 MTNST-162 Magnetic pickup Backup emerg. over-speed protection (2/3 logic) 111 111 111 111 MTNST-163 Magnetic pick up Backup emerg. over-speed protection (2/3 logic) 111 111 111 111 MTNST-164 Magnetic pickup Backup emerg. over-speed protection (2/3 logic) 111 111 111 111 MTNST-165 Magnetic pick up Backup emerg. over-speed protection (2/3 logic) 111 111 111 111 MTNST-169 Magnetic pickup Backup emerg. over-speed protection (2/3 logic) 111 111 111 111 PVNGS UPDATED FSAR TURBINE GENERATOR June 2001 10.2-11 Revision 11

Table 10.2-3 TURBINE OVERSPEED SENSORS AND TRIP SETPOINTS (Sheet 2 of 2)

Setpoints in Percent of Turbine Rated Speed Sensors Type Function HP Stop Valve HP Throttle Valve LP Stop Valve LP Intercept Valve MTNPT-9 Cold RH press trans-mitter Power/load unbalance turbine power None 100 None 102 1 PUE-A004(a)

KW trans-ducer Power/load unbalance anticipatory O/S protection None (b)

None (b)

a. Turbine supplier identification number.
b. Control valves and intercept valves all close in 0.2 second or less following a 150 ms delay when power/load unbalance detects loss of generator load. This could occur before turbine speed starts to increase. This is not a trip.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2001 10.2-12 Revision 11

PVNGS UPDATED FSAR TURBINE GENERATOR June 2003 10.2-13 Revision 12 overspeed protection will be provided by the device not being tested.

Finally, because the turbine-generator overspeed protection system is not a safety system (other than for equipment protection), a single failure analysis per IEEE-279 is not required.

10.2.2.4 Turbine Protective Trips Turbine protective trips are independent of the electronic control system and, when initiated, cause tripping of all turbine stop and control valves. The protective trips are:

Overspeed trip (mechanical): 110% of normal Backup overspeed trip (electrical): 111% of normal Low vacuum trip Excessive thrust bearing wear trip Electric solenoid trip actuated by:

Reactor trip Generator trip Manual trip from control room Excessive vibration trip Manual trip handle located at the turbine front standard High exhaust hood temperature trip Moisture separator drain system high level trip Prolonged loss of stator coolant trip Low hydraulic fluid pressure trip Loss of both speed signals or backup overspeed trip Low bearing oil pressure trip Loss of main shaft oil pump discharge pressure trip

PVNGS UPDATED FSAR TURBINE GENERATOR June 2003 10.2-14 Revision 12 The EHC system employs five electric and one mechanical speed inputs. Signals are redundantly processed in both electronic and hydraulic logic channels. Valve opening actuation is provided by a 1600 psig hydraulic system that is totally independent of the bearing lubrication system. Valve closing actuation is provided by springs and steam forces upon the reduction or relief of fluid pressure. The system is designed so that loss of fluid pressure for any reason leads to valve closing and consequent shutdown.

To help prevent turbine overspeed, a sequential tripping system isolates all steam to the high-pressure turbine and low-pressure turbines, and must detect no load on the generator before the main generator breaker is opened. (See figure 10.2-3.) This system provides for an orderly shutdown from a single tripping signal and prevents a rapid rise in speed that would occur if the generator breaker were opened before the turbine valves closed. All turbine protective trips are done by sequential tripping logic including the manual trip from the control room or by the trip handle at the turbine front standard. In a sequential trip, the interval between the closure of the turbine valves and the opening of the generator breaker is at least 3 seconds. Refer to calculation 13-EC-MA-232. In some electrical faults which would do serious damage to the generator, sequential tripping is not permissible. In these cases the generator and turbine are tripped simultaneously.

It is possible for the operator, in an emergency, to open the main generator breaker from the control room switch instead of using the turbine trip button. This action at or near full load, coupled with transient steam conditions from the steam generator, could cause serious turbine damage and excessive

PVNGS UPDATED FSAR TURBINE GENERATOR June 2003 10.2-15 Revision 12 overspeed. To help prevent the above, the operator is required to hold a breaker bypass switch in "trip" as a permissive before operating the main breaker switch to trip the generator.

Limit switches on the main stop valves, control valves, reheat stop valves, and intercept valves are used in the sequential tripping logic. A reverse power relay is used to detect reverse current flow for the no load condition on the generator. A time delay, which is adjustable in the reverse power relay, is credited for a portion of the 3 second interval between a turbine trip and the loss of power to the RCPs assumed in certain accident analyses. Refer to section 8.3.4 and table 15.0-0. In a sequential trip, the unit auxiliary transformer continues to supply power to the non-Class 1E distribution system during the relay timeout period. Refer to section 8.3.5 and calculation 13-EC-MA-232.

All steam valves are arranged in series pairs such as a main stop valve and associated control valve or a reheat stop and associated intercept valve. There are four pairs of valves for the high-pressure turbine and two pair of valves for each low-pressure turbine making a total of ten pairs of steam admission valves. Each stop valve, control valve, and intercept valve (20 total) is actuated by either of two overspeed trip systems. Four control valves on the high-pressure turbine and one intercept valve on each low-pressure turbine is modulated by the speed governing system. Closure of either valve in a pair stops the steam flow from that source and therefore a single valve failure would not disable the turbine overspeed trip from functioning. The backup overspeed trip and the trip caused by loss of the primary and backup speed signals are initiated by the 24 volt dc trip logic shown on figure 10.2-2.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2001 10.2-16 Revision 11 The 24 volt trip system is used for turbine vital trips which includes the backup overspeed trip. A 125 volt dc trip system is also used for trips from related equipment and several turbine protective trips. As further protection, there is a "cross trip" logic employed which allows all trips originating in the 24 volt dc logic to initiate a trip by the 125 volt dc system. Conversely all trips originating in the 125 volt dc logic will initiate a trip in the 24 volt dc system. The output trip signals from these two voltage levels energize separate and individual solenoid valves which, in turn, dump the pressure off the high-pressure fluid connected to all the turbine steam admission valves.

10.2.2.5 Other Protective Systems In addition to the previously mentioned devices, other protective features of the turbine and steam system are:

A.

Safety valves on the moisture separator-reheater to protect the high-pressure turbine cylinder from over-pressure in the event of a turbine trip B.

With the exception of the last two low-pressure heaters, each steam extraction line is equipped with a nonreturn valve to protect the turbine from overspeed due to reverse flow in case of a turbine trip. Each nonreturn valve will be exercised once per week using a hand air test valve which is located at the nonreturn valve. Movement of the nonreturn valve shaft and counter weight extension will be noted during testing.

C.

Exhaust casing rupture diaphragms to protect the low-pressure turbine cylinders from overpressure in case of loss of condenser vacuum.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2005 10.2-17 Revision 13 10.2.2.6 Plant Loading and Load Following The turbine-generator is intended to be base loaded, but is designed to match or exceed the transient load following capabilities of the NSSS. The reactor regulating system (RRS) automatically adjusts reactor power to follow turbine load transients. The RRS senses turbine first-stage pressure as a linear indication of load and generates signals that regulate control element assembly (CEA) drive direction and speed. As a combined unit consisting of turbine-generator and reactor, the system accepts step load changes of +10% and ramp load changes of

+5%/min over the range of 15 to 100% full power. It also accepts, with the aid of the turbine bypass system, a load rejection of approximately 55% of full load power without reactor trip. For load rejections greater than approximately 55% of full load, reactor power is cut back as described in subsection 10.4.4, and steam is dumped to the condenser as needed. In the event of complete loss of load, the system automatically runs back to house load. If the condenser is not available, concurrent with a load rejection, the reactor is tripped.

The turbine control system is designed to provide protection to the turbine by tripping the turbine for certain predetermined conditions as discussed in paragraph 10.2.2.3. The turbine is tripped upon reactor trip. The reactor protective system provides two separate signals of reactor trip to the turbine control system.

10.2.2.7 Inspection and Testing Requirements Major system components are readily accessible for inspection and are available for testing during normal plant operation.

Controls and protective devices associated with each turbine-generator component will be tested on a regularly scheduled

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-18 Revision 14 basis. Various turbine trips will be tested in sequence prior to unit startup.

The schedules for testing and inspection of the various system components are developed as part of the plant operating procedures presented in section 13.5.

10.2.3 TURBINE DISK INTEGRITY 10.2.3.1 Materials Selection The originally installed General Electric turbine wheels and rotors are made from vacuum melted or vacuum degassed Ni-Cr-Mo-V alloy steel by processes that minimize flaw occurrence and provide adequate fracture toughness. Tramp elements are controlled to the lowest practical concentrations consistent with good scrap selection and melting practices, and consistent with obtaining adequate initial and long life fracture toughness for the environment in which the parts operate. The turbine wheel and rotor materials have the lowest fracture appearance transition temperatures (FATT) and highest Charpy V-notch energies obtainable, on a consistent basis, from water quenched Ni-Cr-Mo-V material at the sizes and strength levels used. Since actual levels of FATT and Charpy V-notch energy vary depending upon the size of the part and the location within the part, etc., these variations will be taken into account in accepting specific forgings for use in turbines for nuclear application. Charpy tests essentially in accordance with Specification ASTM A370 are included.

The replacement General Electric Low Pressure Rotors are manufactured as a monoblock forging and do not have shrunk on wheels to preclude brittle failure at the wheel bore region.

The monoblock forging material chemistry is optimally balanced to achieve high hardenability, good fracture toughness at the

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-19 Revision 14 required tensile strength, low tramp elements to minimize temper embrittlement and low sulfur to minimize harmful segregation. This material is similar to ASTM 470 Class 6 but with more restrictive quality requirements.

The rotor forging is semi-machined to provide suitable surface for a periphery ultrasonic inspection. After final heat treatment a series of NDT testing is performed to ensure rotor structural integrity. Specimen testing of the rotors is performed to assure the rotors meet the suppliers material specifications. Charpy tests essentially in accordance with Specifications ASTM A370 and ASTM A470 are included. A copy of all these test records and inspections for each rotor are submitted by GE and included in SDR log 13-M400-0303-1036.

1 10.2.3.2 Fracture Toughness Suitable material toughness is obtained through the use of materials described in paragraph 10.2.3.1 to produce a balance of adequate material strength and toughness to ensure safety while simultaneously providing high reliability, availability, and efficiency during operation. For the original General Electric turbines, bore stress calculations include components due to centrifugal loads, interference fit, and thermal gradients where applicable. The ratio of material fracture toughness, KIC (as derived from material tests on each wheel or rotor) to the maximum tangential stress for wheels and rotors at speeds from normal to 115% of rated speed (a) will be at least 2 inches. Adequate material fracture toughness needed to maintain this ratio is assured by destructive tests on material taken from the wheel or rotor using correlation methods which are more conservative than that presented in reference 1.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-20 Revision 14 Turbine operating procedures are employed to preclude brittle fracture at startup by ensuring that the metal temperature of wheels and rotors (a) is adequately above the FATT, and (b) as defined above is sufficient to maintain the fracture toughness to tangential stress ratio at or above 2 inches. For original General Electric turbines details of these startup procedures are contained in reference 2.

10.2.3.3 High-Temperature Properties The operating temperatures of the high-pressure rotor in turbines operating with light-water reactors are below the creep rupture range. Creep rupture is, therefore, not considered to be a significant factor in assuring rotor integrity over the lifetime of the turbine. Basic data is obtained from laboratory creep rupture tests.

10.2.3.4 Turbine Disk Design The original General Electric turbine assembly is designed to withstand normal conditions and anticipated transients including those resulting in turbine trip without loss of structural integrity. The design of the turbine assembly meets the following criteria:

A.

The maximum tangential stress in wheels and rotors resulting from centrifugal forces, interference fit, and thermal gradients does not exceed 0.75 of the yield strength of the materials at 115% of rated speed.

a.

The highest anticipated speed resulting from a loss of load is 110%.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-21 Revision 14 B.

Turbine shaft bearings are designed to retain their structural integrity under normal operating loads and anticipated transients, including those leading to turbine trips.

C.

The multitude of natural critical frequencies of the turbine shaft assemblies existing between zero speed and 20% overspeed are controlled in the design and operation so as to cause no distress to the unit during operation.

GE, in the course of designing the new turbine for Palo Verde

  1. 1, 2 and 3, has evaluated tensile stresses in rotating components. All of the rotating components have sufficient margin to tensile strength at design component temperatures to support operating speeds well in excess of 120% of normal. For example, the overspeed capability of the un-bucketed HP and LP rotors is over 200%. The most limiting components, per design, for the bucketed rotors are the LP L-0 buckets which have a minimum overspeed capability of 170%. The design of some of the most critical parts of the monoblock rotor assembly meet the following criteria:

A.

The new monoblock rotors utilize tangential entry pinetree dovetails to attach the first five stages of buckets and radial entry finger dovetails to attach the last two stages. The wheel tangential entry dovetails are shot peened to introduce a compressive stress layer for protection against Stress Corrosion Cracking (SCC). In addition, the critical areas that are susceptible to SCC are designed such that the peak stresses do not exceed 55 percent of the material yield strength.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-22 Revision 14 B.

Turbine shaft bearings are designed to retain their structural integrity under normal operating loads and anticipated transients, including those leading to turbine trips.

C.

The multitude of natural critical frequencies of the turbine shaft assemblies existing between zero speed and 20% overspeed are controlled in the design and operation so as to cause no distress to the unit during operation.

10.2.3.5 Preservice Inspection The preservice inspection program is as follows:

A.

The original wheel and rotor forgings and the new monoblock forgings are rough machined with minimum stock allowance prior to heat treatment.

B.

Each original rotor and wheel forging and new monoblock forging is subjected to a 100% volumetric (ultrasonic) examination. Each finish-machined original rotor and wheel and new monoblock forging is subjected to a surface magnetic particle and visual examination. Results of the above examination will be evaluated by use of General Electric acceptance criteria. These criteria are most restrictive than those specified for Class 1 components in the ASME Boiler and Pressure Vessel Code, Sections III and V, and include the requirement that subsurface sonic indications are either removed or evaluated to assure that they do not grow to a size which compromises the integrity of the unit during the service life of the unit.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-23 Revision 14 C.

Finish-machined surfaces are subjected to a magnetic particle examination. No magnetic particle flaw indications are permissible in bores, holes, keyways, and other highly stressed regions.

D.

Each fully bucketed turbine rotor assembly is spin tested at or above the maximum speed anticipated following a load rejection from full load.

10.2.3.6 Inservice Inspection The inservice inspection program for the turbine assembly and valves includes the following:

A.

Disassembly of the turbine is conducted during selected plant shutdowns. Inspection of parts that are normally inaccessible when the turbine is assembled for operation, such as couplings, coupling bolts, turbine shafts, low-pressure turbine buckets, low-pressure wheels, and high-pressure rotors, is conducted. This inspection consists of visual, surface, and volumetric examinations.

B.

Dismantle at least one main steam stop valve, one main steam control valve, one reheat stop valve, and one reheat intercept valve during selected refueling or maintenance shutdowns, and conduct a visual and surface examination of valve seats, wheels, and stems. If unacceptable flaws or excessive corrosion are found in a valve, other valves of its type are inspected. Valve bushings are inspected and cleaned, and bore diameters are checked for proper clearance.

C.

Main steam stop, reheat stop, and intercept valves will be exercised at least once a week by closing each valve

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-24 Revision 14 and observing by the valve position indicator that it moves smoothly to a fully closed position. The control valves will be exercised monthly. At least once a month, this examination will be made by direct observation of the valve motion.

D.

Extraction steam valves will be exercised once per week using a hand air test valve which is located at the nonreturn valve. Movement of the nonreturn valve shaft and counterweight extension will be noted during testing.

10.2.4 EVALUATION 10.2.4.1 Power Generation Components of the turbine-generator are conventional and are types that have been extensively used in other nuclear power plants. Instruments, controls, and protective devices are provided to ensure reliable and safe operation. Redundant, fast actuating controls are installed to prevent any damage resulting from overspeed and/or full load rejection. The control system ensures turbine trip upon reactor trip.

Automatic low-pressure exhaust hood water sprays prevent excessive hood temperatures. Exhaust casing rupture diaphragms prevent low-pressure cylinder overpressure in the event of loss of condenser vacuum.

Since the steam generated in the steam generators is not normally radioactive, no radiation shielding is provided for the turbine-generator and associated components. Thus, radiological considerations do not affect access to system components during normal conditions. In the event of a primary-to-secondary system leak due to a steam generator tube leak, it is possible for the main steam to become radioactively

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-25 Revision 14 contaminated. Discussions of the radiological aspects of primary-to-secondary leakage are presented in chapters 11 and

12.

10.2.4.2 CESSAR Interface Evaluation Refer to subsections 5.1.5 and 7.2.4.

10.2.5 INSTRUMENTATION APPLICATIONS The turbine-generator is provided with a full complement of turbine supervisory instruments mounted in the control room, complete with sensors and/or transmitters mounted on the associated equipment, which indicate and record the following:

Speed Stop valve position Control valve position Intercept valve position Temperatures as required for controlled starting, including:

Steam chest Nozzle bowl First-stage steam and drain High-pressure casing drain High-pressure exhaust First-stage reheater outlet Second-stage reheater outlet

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-26 Revision 14 Casing expansion Casing and shaft differential expansion Vibration at each bearing Shaft eccentricity Bearing oil drain, shaft bearing sleeve, and thrust bearing plate temperatures Shaft axial position Control room alarms are provided to warn the operators of the following abnormal conditions:

High vibration High eccentricity High differential expansion High bearing temperature High exhaust hood temperature alarm Turbine trip (for each independent redundant channel)

Low vacuum Thrust bearing wear Low bearing oil pressure Low steam seal pressure High gland seal condenser pressure (or low vacuum)

Overspeed trip (for each independent redundant channel)

High-low level in moisture separator drain tank

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-27 Revision 14 Local and control room indication of the following miscellaneous parameters are provided:

Main steam chest pressure Steam seal header pressure Gland seal condenser vacuum Bearing oil header pressure Hydraulic header pressure Crossover pressure Moisture separator drain tank level (local only)

First-stage pressure High-pressure turbine exhaust pressure Extraction steam pressure, each extraction point (via computer)

Exhaust hood spray water flow Exhaust hood temperature, each exhaust Instrumentation and controls are provided in the control room for the generator equipment as follows:

A.

Generator supervisory instruments with sensors and/or transmitters mounted on the associated equipment, indicating or recording the following:

1.

Multiple generator stator winding temperatures.

The detectors are built into the generator, fully protected from the cooling medium, and suitably distributed around the circumference in positions having the highest temperature.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-28 Revision 14

2.

Multiple stator winding cooling coil outlet temperature detectors

3.

Stator coolant inlet and discharge temperatures

4.

Hydrogen cooler inlet gas temperature (two detectors at each point)

5.

Field temperature

6.

Hydrogen gas pressure

7.

Hydrogen gas purity

8.

Generator winding over temperature.

B.

Alarms are provided for high stator, hydrogen, stator coil coolant, and field temperature. An alarm is provided from a core monitoring system to indicate a local core overheating condition.

PVNGS UPDATED FSAR TURBINE GENERATOR June 2007 10.2-29 Revision 14 10.

2.6 REFERENCES

1.

Begley, J. A., and Logsdon, W. A., Westinghouse Scientific Paper 71-1E7-MSLRF-P1.

2.

Spender, R. C., and Timo, D. F., Starting and Loading of Turbines, General Electric Company, presented at the 36th Annual Meeting of the American Power Conference, Chicago, Illinois, April 29-May 1, 1974.

3.

Turbine Generator Final Report 105% core Thermal Uprate Study, SDR log 13-M400-0303-01036.

This page intentionally blank

PVNGS UPDATED FSAR June 2007 10.3-1 Revision 14 10.3 MAIN STEAM SUPPLY SYSTEM The function of the main steam supply system is to deliver steam from the steam generators to the high-pressure turbine over a range of flows and pressures covering the entire operating range from system warmup to valves-wide-open (VWO) conditions. The system also provides steam to the moisture separator/reheaters, the feedwater pump turbines, the auxiliary steam system, and the steam seal system for the main and the feedwater pump turbines.

Under certain conditions the Auxiliary Steam condensate cross connection header may be connected to the Secondary Chemistry Condensate Cleanup System in order to transfer water from the steam generators to the Chemical Waste Neutralization Tanks.

This capability is discussed further in Section 10.4.6.

10.3.1 DESIGN BASES 10.3.1.1 Safety Design Bases Pertinent safety design bases are as follows:

A.

Safety Design Basis One The system provides a means of dissipating heat generated in the nuclear steam supply system (NSSS) during normal power operation, plant startup, hot shutdown, hot standby, and cooldown, even if the main condenser is unavailable. Atmospheric dump valves are provided to allow cooldown of the steam generator when the condenser is not available.

B.

Safety Design Basis Two The system is provided with automatically operated isolation valves on the main steam lines. These valves are located outside of and as close as possible to the containment in accordance with the requirements of Criterion 57 of 10CFR50.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-2 Revision 11 C.

Safety Design Basis Three The system, from the secondary side of the steam generators and up to and including the main steam isolation valves (MSIVs) and the main steam isolation valve bypass valves, is designed to withstand the effects of a safe shutdown earthquake (SSE). The safety-related portions of the system are capable of withstanding the effects of natural phenomena.

D.

Safety Design Basis Four Main steam system components important to safety are designed to accommodate the effects of and to be compatible with the environmental conditions associated with normal operation, testing, and postulated accidents, including loss-of-coolant accidents (LOCAs), in accordance with 10CFR50, Appendix A, General Design Criterion 4.

E.

Safety Design Basis Five The main steam piping and supports are designed so that a single failure in the main steam system will have no contributory effects on:

Initiation of a LOCA Integrity of other steam lines The capability of the engineered safety features system to effect a safe reactor shutdown Transmission of excessive loading to the containment pressure boundary

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-3 Revision 11 F.

Safety Design Basis Six The portion of the main steam system that is constructed in accordance with ASME Section III, Class 2, requirements is provided with access to welds and removable insulation as required for inservice inspection in accordance with ASME Section XI, Rules for Inservice Inspection of Nuclear Reactor Coolant Systems.

G.

Safety Design Basis Seven Flow restrictors are installed in the steam generator steam nozzles to limit flow in the event of a main steam line break.

H.

Safety Design Basis Eight Provide steam to the auxiliary feedwater pump turbine.

10.3.1.2 Power Generation Design Basis The main steam supply system delivers the steam from the steam generators to the high-pressure turbine for a range of flows and pressure varying from system warmup to maximum operating conditions. It also provides steam to the moisture separator reheater, the feedwater pump turbines, the auxiliary steam system, and the turbine gland steam seal system.

10.3.1.3 Environmental Design Bases Refer to section 3.11 and CESSAR Section 3.11 for a discussion of environmental design bases.

10.3.1.4 Codes and Standards The main steam supply is designed in accordance with the codes and standards identified in table 3.2-1.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2003 10.3-4 Revision 12 10.3.1.5 CESSAR Interface Requirements Refer to subsection 5.1.4.

10.

3.2 DESCRIPTION

10.3.2.1 General Description The main steam supply system, shown in engineering drawings 01, 02, 03-M-SGP-002 and -001, includes the following major components:

Main steam piping from the steam generator nozzles to the main turbine stop valves One main steam isolation valve per main steam line Main steam safety valves, 5 per main steam line Atmospheric dump valves, 1 per main steam line Table 10.3-1 lists the design data covering the major components of the main steam supply system.

10.3.2.2 Component Description 10.3.2.2.1 Main Steam Piping The main steam lines deliver the required steam flow from the secondary side of the two steam generators to the high-pressure turbine; while brunch lines deliver steam to the moisture separator/reheater, feedwater pump turbines, steam seal system, and the auxiliary steam system. Each of the main steam lines from the steam generators is anchored at the containment wall and has sufficient flexibility to accommodate thermal expansion. Design of the attachment of the main steam piping to the steam generators includes design considerations that incorporate the allowable nozzle loading moments and stresses for both steam generators operating, or with one of them out of service. The design of all piping and supports

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-5 Revision 11 considers all static and dynamic loadings, stresses, and moments arising from normal operation, pressure transients, or pipe rupture. The design of Seismic Category I piping and supports considers the loads discussed in subsection 3.9.3.

Each main steam line contains five spring-loaded safety valves, one atmospheric dump valve, and one isolation valve. All of these valves are located outside the containment and are installed as close as possible to the containment wall.

Containment penetrations are discussed in subsection 6.2.4.

Turbine bypass valves are provided between the main steam isolation valves and turbine generator stop valves as discussed under the turbine bypass system (refer to subsection 10.4.4).

Connections are provided for nitrogen pressurization of the steam generators. Also, sample connections are provided downstream of the steam generator nozzles for determination of steam quality. Branch piping provides steam to moisture separator reheaters, main and feedwater pump turbine gland steam sealing systems, the feedwater pump turbines, the auxiliary feedwater pump turbine, and the bypass steam to the condenser and to atmosphere.

The main steam lines are designed to permit preoperational cleaning to remove foreign material and rust. The design is such as to prevent entry of foreign material into either the steam generators or turbine-generator. The main steam piping drops several feet immediately downstream of the steam generators prior to being routed to the turbine stop valves.

The lines are sloped in the direction of the turbine, and drains are provided at all low points to provide for flushing and drainage.

Pertinent design parameters for the main steam piping out to the main steam isolation valve are presented in table 10.3-2.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-6 Revision 13 Table 10.3-1 MAIN STEAM SUPPLY SYSTEM DESIGN DATA (Sheet 1 of 2)

Component Parameter Main steam piping Steam flow at Rated power (Reactor Power of 3800 MWt),

10 6 lb/hr at rated Power (Reactor Power of 3990 MWt), 10 6 lb/hr 17.2 17.96 at VWO power, (Reactor Power of 3800 MWt), 10 6 lb/hr at VWO power, (Reactor Power of 3990 MWt), 10 6 lb/hr 18.1 18.45 Number of main steam lines 4

Pipe size, OD in.

28 Design pressure, psig 1255 Design temperature, °F 600 Pipe material ASME SA-155 grade KCF 70, class I carbon steel Pressure drop from steam generator to stop valve at VWO, psi at Rated Power (Reactor Power of 3880 MWt), psi at Rated Power (Reactor Power of 3990 MWt), psi 39 33 19.8 at Turbine Guarantee, psi 33 Main steam isolation valves Number per main steam line 1

Total number required 4

Atmospheric dump valves Number per main steam line 1

Total number required 4

Design relieving capacity per valve 100% open, lb/h (at 1000 psia) 1.47 x 10 6

Controllable capacity per valve, lb/h (at 1170 psia) 63,000 Main steam safety valves Number per main steam line 5

Total number required 20

PVNGS UPDATED UFSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-7 Revision 11 Table 10.3-1 MAIN STEAM SUPPLY SYSTEM DESIGN DATA (Sheet 2 of 2)

Component Parameter Main steam safety valves (Cont.)

Set pressure, psig No. 1 No. 2 No. 3 No. 4 No. 5 1250 1290 1315 1315 1315 Orifice size, in 2

No. 1 No. 2 No. 3 No. 4 No. 5 16.0 16.0 16.0 16.0 16.0 Inlet/Outlet size, in./in.

No. 1 No. 2 No. 3 No. 4 No. 5 6 x 10 6 x 10 6 x 10 6 x 10 6 x 10 Minimum rated relieving capacity, per valve, at 3% accumulation, 10 5 lb/h:

VALVE NUMBER S/G No. 1

a.

SGE PSV 572

b.

SGE PSV 579

c.

SGE PSV 573

d.

SGE PSV 578

e.

SGE PSV 574

f.

SGE PSV 575

g.

SGE PSV 576

h.

SGE PSV 577

i.

SGE PSV 691

j.

SGE PSV 692 S/G No. 2 SGE PSV 554 SGE PSV 561 SGE PSV 555 SGE PSV 560 SGE PSV 556 SGE PSV 557 SGE PSV 558 SGE PSV 559 SGE PSV 694 SGE PSV 695 Parameter 9.415 9.415 9.713 9.713 9.899 9.899 9.899 9.899 9.899 9.899 Total (20 valves), 10 6 lb/h 19.53 Total maximum actual relieving capacity (20 valves), 10 6 lb/h 22.258

[Editing Note: The truncated parameter value bounds the CTS Value]

PVNGS UPDATED UFSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-8 Revision 11 The main steam piping out to the first isolation valve is inspected and tested in accordance with ASME Code, Sections III and XI. ANSI B31.1 piping is inspected and tested in accordance with Paragraphs 136 and 137 of ANSI B31.1.

10.3Property "ANSI code" (as page type) with input value "ANSI B31.1.</br></br>10.3" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..2.2.2 Main Steam Isolation Valves Each of the main steam lines is equipped with one quick acting main steam isolation valve (MSIV). Each valve has an actuation time of 4.6 seconds or less and operates automatically in the event of rupture in the main steam piping or associated components either upstream or downstream of the MSIV. They prevent blowdown of more than one steam generator (assuming a single active failure of an MSIV to close coincident with rupture) based on the MSIVs ability to close against maximum design differential pressure in either direction. The valves are designed to close upon loss of electric power. Once isolation is initiated, in response to a main steam isolation signal (MSIS), the valves continue to close and cannot be opened until the initiating MSIS is reset or overridden manually by the operator in the control room.

Table 10.3-2 MAIN STEAM ISOLATION VALVE EXPECTED LEAKAGE Differential Pressure (psi)

Pressurized (Upstream/Downstream)

Seat Leakage 1400 Downstream (after steam line break) 0.1% VWO steam flow 1400 Upstream (after steam line break) 0.001% VWO steam flow

PVNGS UPDATED UFSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-9 Revision 13 Each valve has two physically separate and electrically independent solenoid actuators in order to provide redundant means of valve operation. Refer to table 10.3-2 for valve leakage.

The main steam isolation valves are installed in the straight piping runs outside the containment. Table 10.3-3 tabulates all flow paths that branch off the main steam lines between the MSIVs and the turbine stop valves and provides information, including valve positions, to determine performance in the event of steam line break upstream of the MSIV. For those valves which remain open, the total steam flow through these valves is approximately 251,200 lbm/hr. The auxiliary feedwater pump (AFW) delivers at least 316,000 lbm/hr (650 gpm @ 180F.), to the intact steam generator at 1270 psia. Therefore, in the event of a postulated MSLB on one steam generator, and one MSIV failure to close on the intact steam generator, an auxiliary feedwater pump can provide sufficient make-up to the intact steam generator.

The maximum stress level does not exceed the criteria specified in subsection 3.9.3. As noted in UFSAR Sections 15.1.5 and 15.1.6, however, the single failure of a HPSI pump to start on demand is more limiting for postulated MSLBs, than the single failure of an MSIV to close.

A mechanistic main steam line pipe rupture is not postulated to occur between the containment penetrations and the MSIVs nor between the MSIVs and the double concrete wall (designed as a pipe whip restraint) downstream from the MSIVs. However, the main steam support structure and safety-related equipment within are designed to withstand the temperature and pressure effects of a single area pipe break.

The bending moment resulting from a main steam line rupture downstream of the pipe whip restraint is absorbed by the pipe

PVNGS UPDATED UFSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-10 Revision 11 whip restraint and the MSIV nozzle has no bending moment transmitted to it.

The steady-state discharge thrust load from such a break does not cause nozzle bending or torsion. Axial thrust is resisted and balanced at the penetration.

Table 10.3-3 FLOW PATHS ORIGINATING AT MAIN STEAM LINES (Sheet 1 of 2)

System Identification Max.

Steam Flow (LB/HR)

Type of Shut-off Valves Size of Valve Quality of Valve Design Code of Valve Closure Time of Valve (Seconds)

Actuation Mechanism Motive or Power Source Closure Signal (Sensor)

Quality of Power Source Quality of Air Supply Positive Status of Valve After MSIV Isolation Comment SG-V093 (or AS-V004) 82,600 Gate (Gate) 6" Non-Q ANSI B31.1 15 Manual N/A N/A N/A N/A Open

}

Aux. steam supply to control valves PV-5A/B,PV-6 (13-M-ASP-001)

(13-M-SGP-001)

SG-V094 (or AS-V012) 82,600 Gate (Gate) 6" Non-Q ANSI B31.1 15 Manual N/A N/A N/A N/A Open SG-V095 (or AS-V013) 50,000 Globe (Gate) 3" Non-Q ANSI B31.1 10 Manual N/A N/A N/A N/A Open MT-UV-1004 (or UV-1005) 4.25 X 106 Globe 28" Non-Q ANSI B31.1 0.2 Hydraulic Trip of turbine speed control system (actu-ated on MSIS parameters)

MSIS Actuation Signal (Low S/G Pressure)

Non-IE N/A Closed

}

Main steam supply to main turbine (13-M-MTP-001)

MT-UV-1006 (or UV-1007) 4.25 X 106 Globe 28" Non-Q ANSI B31.1 0.2 Hydraulic Trip of turbine speed control system (actu-ated on MSIS parameters)

MSIS Actuation Signal (Low S/G Pressure)

Non-IE N/A Closed MT-UV-1002 (or UV-1001) 4.25 X 106 Globe 28" Non-Q ANSI B31.1 0.2 Hydraulic Trip of turbine speed control system (actu-ated on MSIS parameters)

MSIS Actuation Signal (Low S/G Pressure)

Non-IE N/A Closed MT-UV-1000 (or UV-1003) 4.25 X 106 Globe 28" Non-Q ANSI B31.1 0.2 Hydraulic Trip of turbine speed control system (actu-ated on MSIS parameters)

MSIS Actuation Signal (Low S/G Pressure)

Non-IE N/A Closed SG-UV-031 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor Non-IE N/A Non-IE N/A Closed

}

Bleed off line between MSIVs and turbine stop valves closes on turbine trip (normally closed MOVs)

(13-M-SGP-001)

SG-UV-032 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor 480V N/A Non-IE N/A Closed SG-UV-033 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor 3 Phase N/A Non-IE N/A Closed SG-UV-034 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor 60 Cycle N/A Non-IE N/A Closed SG-UV-035 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor Non-IE N/A Non-IE N/A Closed SG-UV-036 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor 480V N/A Non-IE N/A Closed SG-UV-037 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor 3 Phase N/A Non-IE N/A Closed SG-UV-038 50,000 Globe 2"

Non-Q ANSI B31.1 10 Motor 60 Cycle N/A Non-IE N/A Closed June 2001 10.3-11 Revision 11 PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM

Table 10.3-3 FLOW PATHS ORIGINATING AT MAIN STEAM LINES (Sheet 2 of 2)

System Identification Max. Steam Flow (LB/HR)

Type of Shut-off Valves Size of Valve Quality of Valve Design Code of Valve Closure Time of Valve (Seconds)

Actuation Mechanism Motive or Power Source Closure Signal (Sensor)

Quality of Power Source Quality of Air Supply Positive Status of Valve After MSIV Isolation Comment SG-PV-1007 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Instrument Air Non-IE ANSI B31.1 Closed Main steam blow-down at atmos vent restrictor (13-M-SGP-001)

SG-PV-1008 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Non-IE ANSI B31.1 Closed SG-PV-1002 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Non-IE ANSI B31.1 Closed Main steam blow down to condenser (13-M-SGP-001)

SG-PV-1001 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Solenoid permissive to open (Non-ie 120V dc)

SGBD permissive signal logic (Non-IE 120V ac MFW pump trip logic (MSIS)

(a)

Load sensing logic on main turbine, (i.e.,

pressure switch PSL 512)

Control room hand switch Non-IE ANSI B31.1 Closed SG-PV-1003 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Non-IE ANSI B31.1 Closed SG-PV-1004 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Non-IE ANSI B31.1 Closed SG-PV-1005 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Non-IE ANSI B31.1 Closed SG-PV-1006 1,240,000 Globe 12" Non-Q ANSI B31.1 15 Pneumatic Non-IE ANSI B31.1 Closed FT-HV-65 120,000 Globe 5"

Non-Q ANSI B31.1 0.3 Hydraulic MFW Pump Turgine Speed Control System Non-IE N/A Closed Main steam supply to MFW pump turbine (or HV-67) 120,000 Globe 5"

Non-Q ANSI B31.1 0.3 Hydraulic Non-IE N/A Closed FT-HV-66 120,000 Globe 5"

Non-Q ANSI B31.1 0.3 Hydraulic Non-IE N/A Closed (or HV-68) 120,000 Globe 5"

Non-Q ANSI B31.1 0.3 Hydraulic Non-IE N/A Closed MT-UV-328B 262,500 Globe 10" Non-Q ANSI B31.1 75 Motor Electrical (Non-IE, 480V 3 phase 60 cycle Non-IE N/A Closed Main steam supply to moisture separator reheater MT-UV-328A 262,500 Globe 10" Non-Q ANSI B31.1 75 Motor Non-IE N/A Closed MT-UV-328D 262,500 Globe 10" Non-Q ANSI B31.1 75 Motor Non-IE N/A Closed MT-UV-328C 262,500 Globe 10" Non-Q ANSI B31.1 75 Motor Non-IE N/A Closed GS-HV-005 36,000 Gate 4"

Non-Q ANSI B31.1 10 Motor Electrical (Non-IE, 480V 3 phase 60 cycle Non-IE N/A Open (closed by plant operator)

Main steam supply to gland seal June 2009 10.3-12 Revision 15 PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-13 Revision 11 The bending and axial loads resulting from a postulated main steam line break inside the containment are absorbed by the containment penetration which is designed to withstand pipe collapsing moments and axial thrust.

The operability of the MSIVs is thus unaffected by the above postulated main steam line breaks.

The MSIVs are designed, manufactured, inspected, tested, and certified in accordance with the requirements of the ASME Code,Section III.

The supplier of the MSIVs has designed the valve body to the specified design pressure and temperature and designed the disc, piston, cylinder, connecting shaft, and all other valve and operational components subject to the closing and opening loads within the specified operational time limits to the design differential pressure (in either direction). Disc load and disc assembly inertia load are safely transferred to the valve body.

Total load combinations and stress limits (including pressure load and disc assembly inertia load acting on the valve seat) meet the requirements of table 3.9-3.

The maximum disc stress due to differential pressure and the inertia load due to the moving disc assembly do not exceed 75%

of the yield strength in bending and 50% of the yield strength in shear of the disc material at the operating temperature.

The MSIVs are qualified for operability in conformance to paragraph 3.9.3.2.1.2.

10.3.2.2.3 Main Steam Safety Valves Each main steam line is provided with five ASME Code, spring loaded safety valves located upstream of the main steam

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2011 10.3-14 Revision 16 isolation valves but outside the containment. The total relieving capacity of these valves is divided equally between the main steam lines and is sufficient to pass the steam flow equivalent to 105% of the plant's maximum steam flow. Design data for the main steam safety valves are included in table 10.3-1. The safety valve pressure accumulation does not exceed 3% and the maximum pressure while relieving is below the maximum allowable of 10% above the steam generator design pressure, in accordance with Article NC-7000 of ASME Section III, Nuclear Power Plant Components Code. The design pressure-temperature rating of the main steam piping is 1270 psia and 600F, which are more conservative than the design conditions for the steam generator secondary side.

10.3.2.2.4 Atmospheric Dump Valves Atmospheric dump valves, one per main steam line, are provided to allow cooldown of the steam generators when the main steam isolation valves are closed, or when the main condenser is not available as a heat sink. Each atmospheric dump valve is sized to hold the plant at hot standby while dissipating core decay heat or to allow a flow of sufficient steam to maintain a con-trolled reactor cooldown rate. No automatic control capability is required or provided. Refer to section 7.4 for discussion of the control of the atmospheric dump valves. A nitrogen accumulator is provided for each valve. The accumulator is designed to Seismic Category I standards and is sized for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> at hot standby plus 9.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> of operation to reach cold shutdown (1) under natural circulation conditions in the event of failure of the normal control air system, with a minimum nitrogen accumulator pressure of 615 psig indicated. Refer to subsection 9.3.6 for a discussion of the nitrogen supply for the atmospheric dump valve accumulators.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-15 Revision 11 10.3.2.3 Radiological Considerations Because the steam from the steam generator is not normally radioactive, no radiation shielding is required for the main steam system and associated components. Thus, radiological considerations will not affect access to system components during normal conditions. In the event of a primary-to-secondary system leak caused by a steam generator tube leak, it is possible for the steam to become radioactively contaminated.

Discussions of the radiological aspects of primary-to-secondary leakage are presented in chapters 11 and 12.

10.3.3 EVALUATION Table 10.3-4 covers the failure mode and effects analysis of the main steam supply system.

10.3.3.1 Safety Evaluation Safety evaluations are numbered to correspond to the safety design bases and are as follows:

A.

Safety Evaluation One Under the following conditions, with the steam generators in service, the power-operated atmospheric dump valves are used to dissipate reactor coolant system energy and core decay heat into the atmosphere:

1.

When the turbine generator or main condenser is not in service

2.

When the plant is being started up or shut down

3.

During core physics testing

4.

Following a turbine-generator trip on loss of main condenser vacuum

Table 10.3-4 MAIN STEAM SYSTEM FAILURE MODE AND EFFECTS ANALYSIS (Sheet 1 of 3)

No.

Name Failure Mode Cause Symptoms and Local Effects Including Dependent Failures Method of Detection Inherent Compensating Provision 1 Main steam isolation valve a) Fails open Solenoid failure None, redundant solenoid will close valve Valve Position Indicator, S. G. Pres-sure and Level Indicators, and steam line flow recorders Each MSIV has redundant trip circuits, sole-noid valves, accumulators, and position indicators.

b) Fails closed Actuator failure Decrease in steam flow to the turbine generators, about 25%

Valve Position Indicator and steam line flow recorders None 2 MSIV bypass valve a) Fails closed Mechanical binding Pneumatic operator failure Main steam isolation valves can't be opened if there is a pressure drop across them Valve position indication in control room Either of two valves can be used to equal-ize pressure in all four steam lines.

b) Fails open Mechanical binding None, if MSIV is open.

If MSIV is shut, then bleedoff of steam generator Valve position indication in control room Affects only one steam generator.

June 2001 10.3-16 Revision 11 PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM

Table 10.3-4 MAIN STEAM SYSTEM FAILURE MODE AND EFFECTS ANALYSIS (Sheet 2 of 3)

No.

Name Failure Mode Cause Symptoms and Local Effects Including Dependent Failures Method of Detection Inherent Compensating Provision 3

Valve, atm dump a) Fails closed Failure of seals or air supply No effect unless coupled with some other failure Valve position indication in control room Backup nitrogen supply. Also, other steam generator atmos-pheric dump valves provide full capability for steam release b) Fails open Mechanical binding About 16% of one steam generator's steam output would be dumped to atmo-sphere. A stuck open ADV will result in both a reactor trip and a MSIS.

Noise level increase, and a decrease in steam genera-tor pressure indicated in control room Blowdown of only one steam generator 4

Main feedwater isolation valve a) Fails open Mechanical binding No effect Periodic tests Two valves in series in each line are avail-able for iso-lation.

Auxiliary feed flow is avail-able via alternate path b) Fails closed Operator failure Loss of 90% of flow to one section of the steam generator. Decrease in steam generator efficiency Low flow indicated on flow indicator Feed to steam generator still available to other sections June 2011 10.3-17 Revision 16 PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM

Table 10.3-4 MAIN STEAM SYSTEM FAILURE MODE AND EFFECTS ANALYSIS (Sheet 3 of 3)

No.

Name Failure Mode Cause Symptoms and Local Effects Including Dependent Failure Methods of Detection Inherent Compensating provision 5 Main feedwater check valve a) Fails closed Mechanical binding No flow to one portion of the economizer in one steam generator. Decrease in efficiency of the steam generator Flow indicator in control room Steam generator feed still available to other sections Feedwater control system will automatically compensate b) Fails open Mechanical binding No effect unless coupled with some other failure Periodic test Closing of containment isolation valve 6 Auxiliary feedwater check valve a) Fails closed Mechanical binding Temporary low feedwater flow to one steam generator Low flow indication in control room Alternate flow paths available.

Feedwater control system compen-sates automatically b) Fails open Mechanical binding No effect unless coupled with some other failure Periodic test None required June 2001 10.3-18 Revision 11 PVGNS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-19 Revision 11

5.

Loss of electric power to plant auxiliaries Controlled cooldown can be accomplished by use of the dump valves.

B.

Safety Evaluation Two Isolation valves are included in the system design.

These valves are described in paragraph 10.3.2.2.2 and their performance under the accident conditions is discussed in chapter 15.

C.

Safety Evaluation Three The main steam system is designed in accordance with seismic criteria set forth in chapter 3. The design of the main steam system with respect to natural phenomena is also discussed in chapter 3.

D.

Safety Evaluation Four All safety-related components in the main steam system are designed to perform their intended function in the normal and accident temperature, pressure, humidity, chemical, and radiation environment in which they will operate. Environmental design bases and qualifications are discussed in section 3.11.

E.

Safety Evaluation Five The main steam lines are routed from the containment to the turbine building with separations provided so that the failure of steam lines or components associated with one steam generator cannot damage the main steam lines, the isolation valves, and atmospheric dump valves associated with the other steam generator, or damage any component required to effect a safe reactor shutdown. Refer to

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2001 10.3-20 Revision 11 sections 3.5 and 3.6 for the discussion of missile and pipe rupture effects.

F.

Safety Evaluation Six Removable insulation and access to welds, in accordance with ASME Section XI requirements, are provided in the main steam supply system.

G.

Safety Evaluation Seven Each steam generator steam outlet nozzle is equipped with a flow limiting device to limit steam flow in the event of a downstream pipe break. Refer to CESSAR Section 5.4.4 for a description of the flow limiting device.

H.

Safety Evaluation Eight A branch connection upstream of the MSIVs from each steam generator provides steam to operate the auxiliary feedwater pump turbine. Refer to subsection 10.4.9.

10.3.3.2 CESSAR Interface Evaluation Refer to subsection 5.1.5.

10.3.4 INSPECTION AND TESTING REQUIREMENTS Refer to section 14.2 for preoperational testing requirements.

Refer to section 3.9 and to the Technical Specifications for inservice testing and inspection requirements.

10.3.5 WATER CHEMISTRY (PWR) 10.3.5.1 Chemistry Control Basis Steam generator secondary side water chemistry control is accomplished by:

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-21 Revision 13 A.

Close control of the feedwater to limit the amount of impurities which can be introduced into the steam generator; B.

Blowdown of the steam generator to reduce the concentrating effects of the steam generator; C.

Chemical addition to establish and maintain an environment which minimizes system corrosion; D.

Preoperational cleaning of the feedwater system; E.

Minimizing feedwater oxygen content prior to entry into the steam generator.

Chemistry limits for secondary steam generator water and feedwater are established in accordance with EPRI PWR Secondary Water Chemistry Guidelines as endorsed by NEI 97-06, Steam Generator Program Guidelines. The EPRI guidelines and their bases represent the industry best practice, as developed from evaluation of the most recent experimental data and plant operating experience. Exceptions are fully evaluated and documented prior to implementation.

Secondary water chemistry is based on all volatile treatment to maintain system pH, ensure a reducing environment, and to scavenge dissolved oxygen present in the feedwater. Boric acid may be added to minimize SCC of the steam generator tubes.

A neutralizing amine such as ammonia, ethanolamine (ETA) and/or dimethylamine (DMA) is added to establish and maintain alkaline conditions in the feed train.

A reducing agent/oxygen scavenger, such as hydrazine is added to establish a reducing environment and to scavenge dissolved oxygen present in the feedwater. The reducing agent/oxygen scavenger also tends to promote the formation of a protective oxide layer

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2009 10.3-22 Revision 15 on metal surfaces by keeping these layers in a reduced chemical state (lower electrochemical potential).

Both the pH agent and the reducing agent/oxygen scavenger can be injected continuously downstream of the condensate polishing demineralizers. These chemicals are added for chemistry control, and can also be added to the upper steam generator feed line when necessary.

Molar Ratio chemistry is monitored and may be controlled to provide additional assurance that aggressive species are not concentrated above their respective molar concentration ratio (anion to cation ratio). Ammonium chloride injection may be utilized as a method to control Molar Ratio within a prescribed band.

Implementation of Boric Acid Treatment per NSSS Vendor recommendations and EPRI BAT Application guidelines is site specific and is controlled by the station chemistry control program. Boron is maintained at very low concentrations in wet layup to minimize excessive use of pH control agent.

pH is dependent on the pH agent used, the implementation of Boric Acid Treatment (BAT), which may be used to mitigate IGA/SCC of steam generator tubes (alloy 690 tubes, and the use of condensate polishing demineralizes. Alternate amine pH agents can be utilized to provide better pH control at the normal operating temperature of PWR steam generators. Implementation of BAT will require adjustment in the pH and boron specifications.

The normal chemistry conditions can be maintained by any plant operating with little or no condenser leakage. The steam generator limits permit operations with minor system fault conditions until the affected component can be isolated and/or repaired.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-23 Revision 13 Secondary water chemistry monitoring is described in section 9.3.2.

Procedures will require prompt corrective action for out of specification secondary water chemistry conditions.

If condenser leakage is indicated, leak isolation procedures are instituted.

The abnormal limits permit operation with minor system fault conditions until the affected component can be isolated and/or repaired. If the abnormal limits are exceeded, plant shutdown procedures are considered.

Sampling of the steam generator water is done on a continuous basis; parameters monitored include pH, conductivity and radiation.

Out of specification chemical conditions are alarmed in the auxiliary building chemistry laboratory, with a common system trouble alarm in the control room.

In addition, recording and management of secondary water chemistry data will be covered by administrative procedures. These procedures will include the following requirements:

A.

The composition, quantities, and addition rates of additives shall be recorded initially and thereafter whenever a change is made; B.

The electrical conductivity and the pH of the bulk steam generator water and feedwater shall be measured continuously (with provision for alternate sampling methods in case of equipment failure);

C.

The electrical conductivity and sodium ion concentration of the condensate is measured continuously. An administrative procedure will specify responsibilities

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-24 Revision 13 for interpretation of secondary water chemistry data, initiation of corrective action, maintaining secondary water chemistry conditions within specifications, and taking such action as is needed to correct out of specification or off control point conditions. The Shift Manager is responsible for initiating corrective action for out of specification chemical parameters.

The Shift Manager is advised in these corrective actions by the senior chemistry technician. Chemistry data sheets and reports are reviewed on a routine basis by unit chemistry management. Procedures will provide guidance for correcting out of specification and off control point conditions and will require prompt action to correct out of specification conditions.

Procedures for secondary water chemistry control and monitoring were available onsite for NRC review 60 days prior to filling the secondary side of a steam generator.

10.3.5.2 Corrosion Control Effectiveness Alkaline conditions in the feedtrain and the steam generator reduce general corrosion at elevated temperatures and tend to decrease the release of soluble corrosion products from metal surfaces. These conditions promote the formation of a protective metal oxide film and thus reduce the corrosion products released into the steam generator.

The reducing agent/oxygen scavenger also promotes the formation of a metal oxide film by the reduction of ferric oxide to magnetite.

Ferric oxide may be loosened from the metal surfaces and be transported by the feedwater. Magnetite, however, provides an adherent protective layer on carbon steel surfaces. The reducing

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-25 Revision 13 agent/oxygen scavenger also promotes the formation of protective metal oxide layers on copper surfaces.

The removal of oxygen from the secondary waters is also essential in reducing steam generator corrosion mechanisms. Low levels of oxygen dissolved in water causes general corrosion that can result in pitting of ferrous metals, particularly carbon steel. Oxygen is removed from the steam cycle condensate in the main condenser deaerating section. Additional oxygen protection is obtained by chemical injection of a reducing agent/oxygen scavenger into the condensate stream. Maintaining a residual level of the reducing agent/oxygen scavenger in the feedwater ensures that any dissolved oxygen not removed by the main condenser is scavenged before it can enter the steam generator.

The presence of free hydroxide (OH

_) can cause rapid corrosion (caustic stress corrosion) if it is allowed to concentrate in a local area. Free hydroxide is avoided by maintaining proper pH control, and by minimizing impurity ingress in the steam generator.

Zero solids treatment is a control technique whereby both soluble and insoluble solids are excluded from the steam generator. This is accomplished by maintaining strict surveillance over the possible sources of feed train contamination (e.g.,: Main Condenser cooling water leakage, air in leakage and subsequent corrosion product generation in the Low Pressure Drain System, etc.). Solids (with the exception of boric acid, if used) are also excluded, as discussed above, by injecting only volatile chemicals to establish conditions which reduce corrosion and, therefore, reduce the transport of corrosion products into the steam generator. Reduction of solids in the steam generator can also be accomplished through the use of full flow condensate demineralization.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-26 Revision 13 In addition to minimizing the sources of contaminants entering the steam generator, continuous blowdown of one and/or both steam generators is employed to minimize their concentration. These systems are discussed in Section 10.4.6. With the low solid levels which result from employing the above procedures, the accumulation of scale and deposits on steam generator heat transfer surfaces and internals is limited. Scale and deposit formations can alter the thermal hydraulic performance in local regions to such an extent that they create a mechanism which allows impurities to concentrate to high levels, and thus could possibly cause corrosion. Therefore, by limiting the ingress of solids into the steam generator, the effect of this type of corrosion is reduced.

Because they are volatile, the chemical additives will not concentrate in the steam generator, and do not represent chemical impurities which can themselves cause corrosion.

10.3.5.3 Chemistry Control Effects on Iodine Partitioning The partition factor assumed for the condenser vacuum pump outlet is discussed in subsection 11.1.8.

10.3.6 STEAM AND FEEDWATER SYSTEM MATERIALS 10.3.6.1 Fracture Toughness The materials are in compliance with the ASME Boiler and Pressure Vessel Code, Sections II and III, 1974 Edition through the Winter, 1975 Addenda. The fracture toughness properties meet the requirements of the Code,Section III, Paragraphs NB-2300, NC-2300, and ND-2300.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2007 10.3-27 Revision 14 10.3.6.2 Material Selection and Fabrication All pipe, flanges, fittings, valves, and other piping material conform to the latest referenced ASME, ASTM, ANSI, or MSS-SP code, including addenda and supplements.

The following code requirements apply:

Stainless Steel Carbon Steel sPipe ANSI B36.19 ANSI B36.10 Fittings ANSI B16.9, B16.11 or B16.28 ANSI B16.9, B16.11 or B16.28 Flanges ANSI B16.5 ANSI B16.5 The following ASME material specifications apply specifically:

ASME SA-155 GR KCF 70 Class 1 (impact tested)

ASME SA-106 GR C (impact tested)

ASME SA-106 GR B ASME SA-234 GR WP-22 ASME SA-234 GR WPB ASME SA-234 GR WPBW (manufactured from ASME SA-516 GR 70 plate)

ASME SA-234 GR WPC (impact tested)

ASME SA-105 ASME SA-182 ASME SA-193 GR B7 ASME SA-194 GR 2H ASME SA-333 GR 6 (impact tested)

ASME SA-335 GR P22 ASME SA-420 GR WPL6 (impact tested)

ASME SA-420 WPL6-W (manufactured from ASME SA-516 GR 70 plate)

(impact tested)

ASME SA-350 LF 2 (impact tested)

ASME SA-403

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-28 Revision 13 ASME SA-312 ASME SA-376 For austenitic stainless steel components, consistency with the recommendations of Regulatory Guide 1.44, Control of the Use of Sensitized Stainless Steel; Regulatory Guide 1.36, Nonmetallic Thermal Insulation for Austenitic Stainless Steel; and Regulatory Guide 1.31, Control of Ferrite Content in Metal, is discussed in section 1.8.

For cleaning and handling of Class 1, 2, and 3 components, the recommendations of Regulatory Guide 1.37, Quality Assurance Requirements for Cleaning of Fluid Systems and Associated Components of Water-Cooled Nuclear Power Plants, and ANSI-N45.2.1-73, Cleaning of Fluid Systems and Associated Components During Construction Phase of Nuclear Plants, are followed as discussed in section 1.8.

With regard to preheat temperatures used for welding of Class 1, 2, and 3 low-alloy steel, the recommendations of Regulatory Guide 1.50, Control of Preheat Temperatures for Welding of Low-Alloy Steel, were followed.

All piping of the main steam system with pipe sizes larger than 2-1/2 inches is grit blasted.

Materials for use in Class 1, 2, and 3 components have been specified to conform to Appendix I of Section III of the Code and to Parts A, B, and C of Section II of the Code. Regulatory Guide 1.85, Code Case Acceptability ASME Section III Materials, has been used in conjunction with the above specifications.

For a discussion of conformance to Regulatory Guide 1.71, Welder Qualification for Areas of Limited Accessibility, refer to section 1.8.

PVNGS UPDATED FSAR MAIN STEAM SUPPLY SYSTEM June 2005 10.3-29 Revision 13 10.

3.7 REFERENCES

1.

Scherer, A. E., Director, Nuclear Licensing, Combustion Engineering, letter to Eisenhut, D. G., Director, Division of Licensing, USNRC, August 12, 1983 (LD-83-074).

This page intentionally blank

PVNGS UPDATED FSAR June 2001 10.4-1 Revision 11 10.4 OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM 10.4.1 MAIN CONDENSER The main condenser is designed to condense and deaerate exhaust steam from the turbine generator and the feedwater pump turbines.

10.4.1.1 Design Bases 10.4.1.1.1 Safety Design Bases The main condenser has no safety function.

10.4.1.1.2 Power Generation Design Bases Power generation design bases are as follows:

A.

Power Generation Design Basis One The main condenser provides a heat sink for the exhaust steam from the turbine-generator and the feedwater pump turbines, as well as for turbine bypass steam and other cycle flows.

B.

Power Generation Design Basis Two The main condenser provides hotwell storage for surge capability and retention of condensate in the event of a condenser tube leak.

C.

Power Generation Design Basis Three The main condenser provides required deaeration of the condensate.

D.

Power Generation Design Basis Four The main condenser is designed to minimize air inleakage into the steam thermal cycle.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-2 Revision 11 E.

Power Generation Design Basis Five The chemistry of the condensate and feedwater is maintained by the secondary chemical system under all normal operating and allowable upset or abnormal conditions.

10.4.1.1.3 Codes and Standards The main condenser is designed in accordance with the applicable codes and standards identified in table 3.2-1.

10.4.1.2 System Description The main condenser is a multi-pressure, three-shell, single-pass, deaerating type of surface condenser with divided waterboxes. The condenser is floor supported and is located beneath the low-pressure turbines. Expansion joints are provided between each turbine exhaust opening and steam inlet connection of the condenser shells. Main condenser design data are given in table 10.4-1. During normal operation, exhaust steam from the low-pressure turbines is directed downward into the condenser shells through exhaust openings in the bottom of turbine casings and is condensed. The condenser also receives vents and drains from feedwater heaters, miscellaneous equipment, valves, and piping. During transient conditions, the main condenser serves as a heat sink for feedwater heater and drain tank high-level dumps and for the turbine bypass steam.

The main condenser is designed to accept up to 41% of the rated steam flow through the turbine bypass system described in subsection 10.4.4. The bypassed steam flow is distributed between the three condenser shells. These conditions are accommodated without increasing the condenser backpressure to

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-3 Revision 11 the turbine trip setpoint or exceeding the allowable turbine exhaust temperature. Provision is made to reduce the bypass steam pressure before exhausting into the condenser distribution manifold. Special considerations were given to the design of the condenser to avoid steam impinging on the tubes. The condenser has titanium tubes conforming to ASTM B388 which eliminate corrosion/erosion problems.

The condenser is cooled by the circulating water system that removes the heat rejected to the condenser. The use of divided water boxes, lined with repairable protective coating to minimize corrosion/erosion, on each shell permits isolation of one-half of the total circulating water flow through each shell. This permits access to the isolated water box on each shell for repair and/or inspection while one-half of the circulating water flows through the other water box. The circulating water system is described in subsection 10.4.5. The condenser hotwells provide 100,000 gallons of water storage, equivalent to that required for 4 minutes of operation at valves wide open load. The hotwells of each of the condenser shells are interconnected. In addition to struts and braces, the first, second, third, and fourth point low-pressure feedwater heaters are installed in the steam dome of each condenser shell.

In the event that a condenser hotwell ruptures, the flooding will not jeopardize the safe shutdown of the plant. At no time would the water enter the auxiliary building, control building, or diesel generator building. The only access to any of these buildings from the turbine building is sufficiently above the turbine building basemat elevation. Since there is no safety-related equipment in the turbine building, none could be affected.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2005 10.4-4 Revision 13 Table 10.4-1 MAIN CONDENSER DESIGN DATA (Sheet 1 of 2)

Design Factor Value Exhaust steam to condenser at VWO load, 9,303,000/

(Reactor Power of 3800 MWt/3990 MWt), lb/h 9,361,830 Total condensate outflow, (Reactor Power of 3800 MWt/3990 MWt), lb/h 12,864,000/

12,752,876 Total condenser duty, Btu/h 9.04 x 10 9

Maximum expected condenser operating 5.0 pressure, in.Hg abs Condenser high operating pressure alarm, 5.5 in.Hg abs Condenser loss of vacuum setpoint for 5.5 bypass valves to close, in.Hg abs Turbine trip vacuum setpoint, in.Hg abs 7.5 Circulating water design flow to 560,000 condenser gal/min Physical Characteristics Value No. of condenser tubes 76,278 Condenser tube material Titanium Total heat transfer surface, ft 2

1,122,860 Overall dimensions High pressure (HP) 90'-4" L; 30'-11" W; 67'-2" H Intermediate pressure (IP) 87'-10" L; 30"-11" W; 67'-2" H Low pressure (LP) 87'-10" H; 30'-11" W; 67'-2" H No. of passes One Total hotwell capacity 100,000 gal

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2005 10.4-5 Revision 13 Table 10.4-1 MAIN CONDENSER DESIGN DATA (Sheet 2 of 2)

Physical Characteristics Value Special design features 3 pressure deaerating type condenser Minimum heat transfer, Btu/h°F sq ft High-pressure stage 533 Intermediate pressure stage 546 Low-pressure stage 560 Steam flow from main turbine Guaranteed power, (Reactor Power of 3800 MWt/3990 MWt)lb/h 9,002,000 9,191,086 Vwo power, (Reactor Power of 3800 MWt/3990 MWt)lb/h 9,303,000 9,361,830 Circulating water temp., °F (Typical)

Normal 87.3 Maximum 94.0 Exhaust steam temperature, °F Normal Without bypass flow 127 With bypass flow 133.8 Maximum Without bypass flow 131 With bypass flow 133.8 Condensate oxygen content cc/liter (at normal circulating water temp.)

Above 24% load 0.005 Below 24% load (circulating water

>0.005 flow is divided)

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-6 Revision 11 Air and noncondensable gases contained in the turbine exhaust steam are collected in the condenser and passed through the air removal section. Here, the noncondensable gases are removed by the condenser air removal system described in subsection 10.4.2. The maximum total condenser air inleakage is 60 standard cubic feet per minute, as calculated in accordance with Heat Exchange Institute Standard. Buildup of noncondensable gases is precluded since the air removal system is in continuous operation. The condenser reduces oxygen concentration in the condensate to 5 ppm or less by deaeration while the final oxygen content is reduced to 0.01 ppm or less by hydrazine injection at the discharge side of the condensate polishing system. The hydrazine injection system is discussed in subsection 10.4.6.

The internal steam dump fittings for the turbine bypass steam consist of double pressure reduction critical flow orifices.

The steam exits in a horizontal direction away from both the turbine and the condenser tubes. In addition, the condenser tubes are protected from high temperature drains by austenitic stainless steel baffles that direct the flow away from the condenser tubes.

Loss of main condenser vacuum, as evidenced by the condenser pressure reaching or exceeding the setpoint of 7.5 in.Hg abs, trips the turbine. However, a standby vacuum pump having 100%

capacity for one condenser shell is provided to prevent loss of vacuum. The pump is on automatic control to assist or take over the service of the operating pump. If the turbine is tripped because of high backpressure, the steam bypass valves close to prevent additional steam from entering the condenser.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-7 Revision 11 Two of the eight bypass valves are directed to atmosphere and open only on high condenser pressure.

Rupture diaphragms on the main turbine exhaust hood are provided to protect the condenser and turbine exhaust hoods against overpressure. Exhaust hood overheating protection is provided by an exhaust hood spray system that uses condensate from the condensate pumps.

In the event of primary-to-secondary tube leakage, radioactive contaminants are present in the steam generator. Radioactive concentrations in the hotwell are given in section 11.1.

During normal operation, there is no gaseous hydrogen going to the main condenser. In the event of a steam generator tube leak, minute quantities of gaseous hydrogen are carried over to the main condenser. As noted in subsection 10.4.2, the condenser air removal system removes the hydrogen.

The reactor coolant system (RCS) is independent of the condenser circulating water system and the condensate and feedwater systems; therefore, the influence of condenser control functions on RCS operation is negligible. Minute changes in reactor power level occur as a result of changes in main turbine cycle efficiency caused by variations in condenser vacuum. However, these reactor power level variations are slight and are limited by the reactor regulating system. Each occurrence that leads to a loss of function of the condenser is accompanied by a loss of condenser vacuum, which is analyzed in section 15.2.

The operating chemistry limits for condensate and feedwater are discussed in section 10.3.5. Excessive leakage of coolant from the circulating water system into the condensate causes the

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-8 Revision 11 condensate demineralizer to be placed in service. This system is also used to maintain water chemistry during startup, shutdown, and other conditions requiring the polishing of the condensate to maintain the required chemistry. The secondary chemistry control system, which controls and monitors the condensate chemistry, is discussed in subsection 10.4.6.

10.4.1.3 Safety Evaluation The main condenser serves no safety function and has no safety design bases.

10.4.1.4 Tests and Inspections Acceptance testing of the main condenser will be performed in accordance with section 14.2.

The condenser shells, hotwells, and waterboxes are provided with access openings to permit inspection and/or repairs.

During unit outages, the condenser shells can be completely filled with water and tested by the fluorescent tracer method for leaks in accordance with ASME Power Test Code 19.21, before returning the condenser to operation.

10.4.1.5 Instrument Application Hotwell level and pressure indications are provided locally and associated alarms are provided in the control room for each condenser shell. The condenser hotwell in each shell contains conductivity cells to provide a means of detecting and locating condenser tube leaks. Rejection of hotwell condensate to the condensate tank is blocked automatically upon an indication of high hotwell cation conductivity. This feature prevents

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-9 Revision 11 transfer of impurities into the condensate tank in the event of a condenser tube leakage. The condensate level in the main condenser hotwell is maintained within proper limits by automatically transferring condensate to or from the condensate tank. Condensate temperature is measured in the suction lines of the condensate pumps. Turbine exhaust hood temperature is monitored and automatically controlled by use of the water sprays. A high condenser backpressure alarm also is provided.

Turbine trip is activated on loss of main condenser vacuum when condenser pressure reaches or exceeds the setpoint. Monitoring of circulating water temperature, pressure, and differential pressure from waterbox to waterbox is provided.

10.4.2 MAIN CONDENSER EVACUATION SYSTEM The main condenser evacuation system for PVNGS is the condenser air removal system (CARS) which establishes and maintains vacuum in the shell side of the condenser and provides for continuous removal of air and noncondensable gases from the condenser during normal power operation and plant startup.

10.4.2.1 Design Bases 10.4.2.1.1 Safety Design Bases The CARS has no safety function.

10.4.2.1.2 Power Generation Design Bases Applicable power generation design bases are as follows:

A.

Power Generation Design Basis One The CARS is designed to remove air and noncondensable gases from the condenser and turbine gland sealing

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2003 10.4-10 Revision 12 system and exhaust them to the atmosphere via the plant vent or through the effluent filtration system to atmosphere via the plant vent when radioactivity is detected.

B.

Power Generation Design Basis Two The CARS establishes and maintains vacuum in the condenser during startup and normal operation.

10.4.2.1.3 Codes and Standards The CARS is designed in accordance with the codes and standards identified in table 3.2-1.

10.4.2.2 System Description The CARS, shown schematically in engineering drawings 01, 02, 03-M-ARP-001, consists of four two-stage mechanical vacuum pumps, a moisture separator, post-filter, charcoal bed adsorber, blower, and associated valves and piping. The design parameters of the system are shown in table 10.4-2.

Operation of the vacuum pumps is initiated from the main control room. These pumps establish a vacuum of approximately 5 inches Hg abs, prior to buildup of steam generator pressure during plant startup.

During normal plant operation, three mechanical vacuum pumps evacuate air and noncondensables from the condenser.

Noncondensable gases, air, and water vapor are drawn from the three condenser shells to the vacuum pumps. The air and noncondensables from the vacuum pumps are directed to the filtration system whenever radioactivity is detected and prior to discharge to the plant vent stack.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2005 10.4-11 Revision 13 Table 10.4-2 CONDENSER AIR REMOVAL AND TREATMENT SYSTEM DESIGN DATA Design Factor Value Vacuum pumps Design air removal capacity, std ft 3/min 180 Number 4

Capacity, each pump, std ft 3/min 60 High efficiency particulate air filters Number 1

Design Noncondensable gas flow, std ft 3/min (a) 1,664 Charcoal bed adsorber Number 1

Vessel material Carbon Steel Bed depth, in.

2 Design temperature, °F 165 Design Noncondensable gas flow, std ft 3/min (a) 1,664

a.

Includes noncondensable gas flow from turbine gland steam seal exhausters.

b.

All values shown in the table that have units of std ft 3/min are based on standard temperature and pressure conditions of 60°F and 14.7 psia, respectively.

If the steam generators develop a primary to secondary leak, the CARS effluents will contain radioactive nuclides. A radiological evaluation of the discharge from the CARS and the basis for this evaluation are discussed in section 11.3. The average and maximum steam generator tube leaks are given in section 11.1. The CARS effluents, after passing through the moisture separators, are

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2005 10.4-12 Revision 13 treated in the effluent treatment system. The post-filter removes particulate radioactivity.

The charcoal adsorber removes iodine. Effluents from the treatment system are monitored for radioactivity by plant vent monitors before being released to the atmosphere via the plant vent stack. The effluent treatment system also treats effluent from the turbine gland sealing system (TGSS).

As long as the CARS is functional, its operation does not affect the RCS. Should the CARS fail completely, a gradual reduction in condenser vacuum would result from the buildup of noncondensable gases. The reduction in vacuum would cause a lowering of turbine cycle efficiency that requires an increase in reactor power to maintain the demanded electric power generation level. The reactor power is limited by the reactor regulating system as described in section 7.7. If the CARS remains inoperable, condenser vacuum decreases to the turbine trip setpoint and a turbine trip is initiated. Loss of condenser vacuum is discussed in section 15.2.

10.4.2.3 Safety Evaluation The CARS has no safety function.

10.4.2.4 Tests and Inspections Tests and inspections of the equipment and piping are performed in accordance with applicable codes and standards prior to operation. CARS standby equipment is cycled periodically to ensure availability. Periodic inservice tests and inspections of the CARS are performed in conjunction with the scheduled maintenance outages.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2005 10.4-13 Revision 13 10.4.2.5 Instrumentation Applications Radioactivity of the effluent from the CARS is indicated and monitored in the main control room. In addition, high activity levels are alarmed.

10.4.3 TURBINE GLAND SEALING SYSTEM The TGSS prevents air leakage into and steam leakage out of the main turbine and feedwater pump turbines.

10.4.3.1 Design Bases 10.4.3.1.1 Safety Design Bases The TGSS has no safety function.

10.4.3.1.2 Power Generation Design Bases Power generation design bases applicable to this system are as follows:

A.

Power Generation Design Basis One The TGSS prevents air leakage into, and steam leakage out of, the turbine through the turbine shaft glands and through various steam valve stems.

B.

Power Generation Design Basis Two The TGSS returns the air-steam mixture to the turbine gland steam packing exhauster (GSC), condenses the steam, returns the drains to the main condenser, and exhausts the noncondensable gases to the atmosphere, via the effluent filtration system whenever radio-activity is detected.

10.4.3.1.3 Codes and Standards The TGSS is designed in accordance with the applicable codes and standards identified in table 3.2-1.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2003 10.4-14 Revision 12 10.4.3.2 System Description The TGSS, shown schematically in engineering drawings 01, 02, 03-M-GSP-001, consists of steam seal supply and exhaust headers, gland steam regulators (GSRs), gland steam packing exhauster, steam packing exhauster drain tank, and the associated piping and valves. For the system to function satisfactorily from startup to full load, a fixed positive pressure in the steam seal supply header and a fixed vacuum in the outer ends of all the turbine glands (refer to table 10.4-3) must be maintained at all loads.

On cold startup of the steam generators or during emergencies when the normal steam supply is not available, sealing steam is provided by the auxiliary boiler. The steam discharge ends of all glands are routed to the GSC that is maintained at a slight vacuum by the redundant motor-driven blowers. The GSC is a shell and tube heat exchanger. Water supplied from the turbine cooling water system is used to condense the steam from the mixture of air and steam drawn from the shaft packings. Drains from the GSC are returned to the main condenser, and the noncondensables are discharged to the atmosphere via the effluent filtration system of the MCES.

PVNGS operates with Auxiliary Steam as the preferred source to provide added protection to the main condenser in case of a main steam isolation signal. As the turbine is brought up to load, steam leakage from the high-pressure packings enters the steam-seal header becoming a steam source to the gland steam header. At higher loads, when more steam is leaking from the HP packings than is required by vacuum packings, the excess steam is discharged to the main condenser.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-15 Revision 11 Table 10.4-3 TURBINE GLAND SEALING SYSTEM Design Data Value Pressure in steam-seal header, psig 3 to 5 Vacuum in gland steam packing exhauster, in.WG 10 to 20 Number of gland steam packing exhausters 1

Number of blowers mounted on gland steam 2

packing exhausters In case of a malfunction of the GSR, a motor-operated bypass valve is opened and manually controlled to maintain steam-seal header pressure. Vacuum in the GSC can be maintained with one or both blowers in operation. Loss of both blowers may cause sufficient steam to blow through the seals into the turbine area and thus necessitate shutdown of the turbine. The radiological evaluation for the turbine gland sealing system is included in section 11.3. Relief valves on the steam-seal header prevent excessive steam seal pressure. The valves are vented to atmosphere. The potential effects of high-energy pipe breaks are covered in section 3.6.

10.4.3.3 Safety Evaluation The TGSS has no safety function.

10.4.3.4 Tests and Inspection Tests and inspection on the TGSS equipment are performed in accordance with applicable codes and standards.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-16 Revision 11 10.4.3.5 Instrumentation Applications Local and control room displays consist of indicating and alarm devices of steam seal header pressure, temperature, and flow.

10.4.4 TURBINE BYPASS SYSTEM The turbine bypass system removes heat from the NSSS and transfers it to the condenser or atmosphere following load rejections and during plant cooldown, plant startup, and hot standby.

For a discussion of environmental conditions for equipment qualification, refer to section 3.11.

10.4.4.1 Design Bases 10.4.4.1.1 Safety Design Bases The turbine bypass system has no safety function.

10.4.4.1.2 Power Generation Design Bases Power generation design bases applicable to the turbine bypass system are as follows:

A.

Power Generation Design Basis One Operate in conjunction with the reactor power cutback system (refer to CESSAR Section 7.7.l.l.6) to prevent reactor trip or opening of the pressurizer or main steam safety valves following load rejections provided the condenser is available.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-17 Revision 11 B.

Power Generation Design Basis Two Remove heat from the NSSS and reject it to the condenser or atmosphere during plant cooldown, plant startup, and hot standby conditions.

C.

Power Generation Design Basis Three Control NSSS thermal conditions to prevent the opening of safety valves following a unit trip.

D.

Power Generation Design Basis Four Control NSSS thermal conditions when it is desirable to have reactor power greater than turbine power, e.g., during turbine synchronization.

E.

Power Generation Design Basis Five Provide pressure-limiting control during the loss of one out of two feedwater pumps.

F.

Power Generation Design Basis Six Provide a CEA automatic motion inhibit (AMI) signal when turbine power and reactor power fall below selected thresholds; provide AMI signal below 15%

reactor power to block automatic control of the reactor below this power level.

G.

Power Generation Design Basis Seven Provide a means for manual control of RCS temperature during NSSS heatup or cooldown.

H.

Power Generation Design Basis Eight Provide for operation of the turbine bypass valves in a manner that minimizes valve wear and maintains controllability.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2003 10.4-18 Revision 12 I.

Power Generation Design Basis Nine Provide for the operation of the turbine bypass valves in a manner to maximize thermal efficiency of the condenser.

J.

Power Generation Design Basis Ten Include redundancy in the design so that neither a single component failure nor a single operator error result in excess steam releases.

K.

Power Generation Design Basis Eleven Provide a condenser interlock which will block turbine bypass flow when unit condenser pressure exceeds a preset limit.

10.4.4.1.3 Codes and Standards All components of the turbine bypass system are designed and constructed in accordance with the applicable codes and standards identified in section 3.2.

10.4.4.2 System Description The turbine bypass system is shown schematically in figure 10.4-1.

The turbine bypass system consists of eight air-operated globe valves and associated instruments and controls. These valves branch from each main steam line downstream of the main steam isolation valve.

Six of these valves direct steam to the condenser and the remaining two vent directly to the atmosphere.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-19 Revision 11 The valves are designed to quick open within approximately 1 second and quick close within approximately 5 seconds or modulate full open or closed within approximately 15 seconds.

The valves are equipped with remote-operated handwheels to permit manual operation at the valve location.

The two valves which exhaust to the atmosphere are the last to open and the first to close during load rejections, thus minimizing the quantity of steam discharged to the environment.

The valves and piping for the system are located in the turbine building.

The valves in the turbine bypass system are designed to fail closed to prevent uncontrolled bypass of steam. Should the bypass valves fail to open on command, the main steam safety valves provide main steam line overpressure protection, and the power-operated atmospheric dump valves provide a means for controlled cooldown of the reactor. The main steam safety valves and power-operated atmospheric dump valves are described in paragraph 10.3.2.2.

In the event of a turbine trip, the amounts of radioactivity released and the resultant offsite doses are those stated in section 15.2. The main steam safety valves and power-operated atmospheric dump valves are used to control the load transient, if the bypass valves are disabled. Because the ASME Code safety valves provide the ultimate overpressure protection for the steam generators, the turbine bypass system is defined as a control system and is designed without consideration for the special requirements applicable to protection systems. Failure of this system will have no detrimental effects on the RCS.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-20 Revision 11 The turbine bypass system removes heat from the NSSS following load rejections and during startup, plant cooldowns, and hot standby. The system removes heat by modulating bypass steam flow. The modulation of the bypass steam is performed by the turbine bypass valves, which receive signals from the steam bypass control system. Refer to section 7.7 for a discussion of the steam bypass control system.

The turbine bypass system provides a design steam dump capacity of at least 55% of the rated main steam flow. This amount of bypass steam capacity in conjunction with the reactor power cutback feature of the steam bypass control system will dissipate enough energy from the NSSS to permit load rejection of any magnitude without lifting the main steam or pressurizer safety valves or tripping the reactor provided the condenser remains available. The effects of postulated system piping failure on safety-related equipment are given in section 3.6.

10.4.4.3 Tests and Inspections A.

Prior to initial operation, the complete turbine bypass system receives a field hydrostatic test and inspection in accordance with ANSI B31.1.

B.

The turbine bypass system is tested under the requirements of the preventative maintenance program on a minimum frequency of every 18 months.

10.4.4.4 Instrumentation Applications The control system for the turbine bypass system is discussed in CESSAR Section 7.7.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-21 Revision 11 10.4.4.5 CESSAR Interface Requirements Refer to subsection 5.1.4.

10.4.4.6 CESSAR Interface Evaluation Refer to subsection 5.1.5.

10.4.5 CIRCULATING WATER SYSTEM The circulating water system (CWS) removes heat from the main condensers and rejects it to the atmosphere using the plant cooling towers.

10.4.5.1 Design Bases 10.4.5.1.1 Safety Design Bases The CWS has no safety function.

10.4.5.1.2 Power Generation Design Bases The power generation design bases are as follows:

A.

Power Generation Design Basis One The circulating water receives the heat rejected by the turbine cycle.

B.

Power Generation Design Basis Two The plant cooling towers in the CWS dissipate waste heat from the turbine thermal cycle and from the plant cooling water system. The plant cooling water system is discussed in subsection 9.2.10.

10.4.5.1.3 Codes and Standards The CWS is designed in accordance with codes and standards specified in table 3.2-1.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2003 10.4-22 Revision 12 10.4.5.2 System Description The CWS consists of the main condenser, cooling towers, circulating water pumps, a chemical injection system, and a makeup and blowdown system. The CWS is shown schematically in engineering drawings 01, 02, 03-M-CWP-001. Table 10.4-4 lists design data of the major components in the system.

The circulating water pumps are motor-driven, vertical, wetpit type, each rated at 25% capacity. The total design flow rate is 560,000 gallons per minute. These pumps take suction from the intake structure of the CWS and pump the circulating water through the main condensers. The CWS cooling water is returned from the main condensers through a common line to the cooling towers. The system is designed with cross-connected discharge piping from the circulating water pumps. The pump discharge lines are equipped with butterfly valves that permit any circulating water pump to be isolated individually.

Each circulating water path is provided with a butterfly valve at the low-pressure shell inlet and at the high-pressure shell outlet. In case of a condenser tube leak in any water box, the system will remain operable at reduced capacity.

The main condenser is discussed in subsection 10.4.1.

The cooling towers are designed for an ambient wet bulb temperature that will not be exceeded more than 5% of the time during the year. The design cooling range, design approach to ambient wet bulb temperature, and the unit data of the towers are shown in table 10.4-4.

In the event of flooding due to a failure in the portion of the circulating water system in the yard area (such as cooling towers, intake structure, buried pipe), the yard is graded in a

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-23 Revision 11 direction to provide drainage of the water away from the power block and spray ponds. Therefore, the safe shutdown capability will not be compromised by flooding of the yard area.

A postulated failure in the circulating water system in the turbine building would flood the turbine building floor. The water would flow out of the building doors and side panels.

The condenser area sumps and the oily waste sump would be filled to overflowing, but they are not safety-related. The condensate demineralizer sump, which is a sealed sump, would not be affected.

Assuming that 684,000 gallons per minute are available at the riser butterfly valve and considering the closing characteristics of the valve, it has been determined that 520,200 gallons would escape through the rupture with a valve closing time of 60 seconds. This amount of water would tend to flood the turbine building floor; however, as previously stated, the water would flow out of and away from the building.

There are no passageways, pipe chases, cableways, or any other flow paths joining the turbine building floor. There are no essential electrical systems in the turbine building floor.

These conclusions are based on the following conditions:

A.

Low-pressure alarms in the circulating pumps discharge line will alert the operators.

B.

Each pump is capable of delivering 171,000 gallons per minute at maximum runout conditions.

C.

The circulating water line crosstie is initially open.

D.

Valve closing time is 60 seconds.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2001 10.4-24 Revision 11 Table 10.4-4 CIRCULATING WATER SYSTEM DESIGN DATA FOR ONE TURBINE UNIT Design Factor Values Circulating water pumps Number 4

Type Vertical, wet-pit Capacity each, gal/min 140,000 Head, ft (TDH) 103 Cooling tower Number 3 Round, mechanical draft Design ambient temperatures Wet bulb temperature, °F 75 Dry bulb temperature, °F 116 Design range, °F 31.5 Design approach, °F 12.3 Unit tower data, VWO Makeup flow, gal/min 19,651 Blowdown flow, gal/min 1,284 Evaporation, gal/min 18,341 Drift, gal/min 26 Cooling tower circulating 587,000 water flow, gal/min Total turbine plant heat 9.1 x 10 9

load, Btu/h Chlorination facilities Chlorine injection rate 3,490 average (yearly average), lb/d

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-25 Revision 14 It is estimated that the operator action time to shut the valves and stop the circulating water pumps would be 20 seconds based on multiple indications of low circulating water pump discharge pressure and high condenser pressure. At 80 seconds, 748,200 gallons of water would have escaped. If the operator should fail to act, then the water would continue to flow out of the turbine building through doors and sidings at grade level 100 feet.

In the event of a failure of the circulating water system in the turbine building, at no time would the water enter the auxiliary building, control building, main steam support structure, or diesel generator building. Finish grade of 0.5% is established to permit flood water from a break in the circulating water system to spread and flow away from safety-related structures (reference Bechtel drawings 01-C-ZVC-400 through 01-C-ZVC-407).

This flow pattern occurs whether the break is in the yard area or within the turbine building. The at-grade door sills in the auxiliary building and main steam support structure (MSSS) are sufficiently above expected water levels resulting from any postulated flooding source. An opening in the MSSS at the 81-foot elevation (a stairwell from the roof of the condensate tunnel) will have a waterproof door installed.

A makeup system is provided to replace water losses due to evaporation, blowdown, and drift from the unit cooling towers.

Makeup water for the CWS is pumped from the water storage reservoirs to the CWS pump intake structure as required. Plant water requirements are covered in paragraph 2.4.11.5.

Salinity buildup in the CWS is controlled by blowing down to the evaporation ponds. Blowdown is taken from the circulating

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2003 10.4-26 Revision 12 water system condenser discharge. Periodic samples are analyzed for dissolved solids, pH, temperature, and radio-activity.

The CWS is designed to prevent any injection of radioactive material into the circulating water. Circulating water passing through the main condenser is at a higher pressure than the steam on the condensing side. Therefore, any leakage, such as from the main condenser tubes, will be from the circulating water into the shell side of the main condenser.

Chemical injection systems add chlorine as sodium hypochlorite, sulfuric acid, and dispersant. The hypochlorite is used to control biological growth and the sulfuric acid adjusts pH in order to minimize corrosion and scaling from calcium carbonate.

A flow diagram of the chemical injection system is shown in engineering drawings 01, 02, 03-M-CWP-001.

Sodium hypochlorite is received into storage from a chemical production system for chlorination. Upon initiation of a timed cycle, hypochlorite is fed to each unit CWS for biological control. The hypochlorite system serves all units, and includes, at each unit, adjustable program control with a residual chlorine analyzer.

In addition to chlorination, a non-oxidizing biocide is used for control of aerobic slime forming bacteria and anaerobic corrosive bacteria, which are relatively unaffected by chlorine alone. The biocide is one which will hydrolyze to less toxic components with time.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-27 Revision 14 10.4.5.3 Tests and Inspections All active components of the system are accessible for inspection during station operation. Performance, hydrostatic, and leakage tests are conducted on the CWS butterfly valves in accordance with applicable codes and standards.

10.4.5.4 Instrumentation Application Temperature and pressure in the CWS lines are measured at the main condensers. In addition, level alarms are provided at the CWS pump intake structure and high discharge pressure is alarmed in the control room.

10.4.6 CONDENSATE CLEANUP SYSTEM Condensate cleanup is performed by the secondary chemistry control system (SCCS) which is an integrated system comprised of the condensate demineralization and blowdown processing subsystem and the chemical monitoring and addition subsystem.

These two subsystems, operating concurrently, provide the capability to maintain the proper operating chemistry of the condensate feedwater and steam generator secondary side water.

The SCCS is shown schematically in engineering drawings 01, 02, 03-M-SCP-002, -003, -001 and -004.

An interconnection exists between Secondary Chemistry (SC) and Auxiliary Steam (AS) condensate piping which permits the condensate cross connection header (APASNL107) to transfer warm (212 °F or less) condensate drained from the steam generators of a unit in operational mode 5 (when the primary system pressure is less than or equal to the secondary system pressure), mode 6, or defueled, to either or both of the other units Chemical Waste Neutralization Tanks for disposal or

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-28 Revision 14 processing. The following conditions and restrictions apply to the use of this interconnection.

1.

The unit discharging secondary coolant is in either Mode 5 and the primary system pressure is less than or equal to the secondary system pressure, or Mode 6, or in a defueled operating condition.

2.

The specific activity of the secondary coolant in both the discharging and the receiving units is less than or equal to PVNGS Technical Specification LCO 3.7.16.

3.

Radiological surveys and controls of ASNL107 will be performed as directed by the Radiation Protection Program.

4.

Prior to transferring water, radiological conditions in the secondary system will be evaluated to ensure the transfer will not have a significant impact on operations in the receiving unit.

5.

ASNL107 should be flushed after the draining of the steam generators to minimize the potential build-up of non-soluble particulates in the line. The flush may be waived if an evaluation of the radiological conditions determines it is not required.

6.

Administrative controls (such as procedures) shall be in place to isolated the flow in the event of a large leak or pipe rupture.

7.

Since flow rate from this modification may approach TDS sump pump capacity, monitor the sump as needed to ensure that is does not overflow.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-29 Revision 14

8.

During Operational Modes 1 through 4, valves 13PSCNV955 and 13PSCNV956 are to be verified closed and locked if not in use.

9.

After use of pipe 13PSCNL479 and closure of 13PSCNV955 and 13PSCNV956, 13PSCNL479 must be drained.

10.4.6.1 Design Bases The condensate cleanup system has no safety function.

10.4.6.1.1 Condensate Demineralization and Blowdown Processing Design Bases The following design bases apply to the condensate demineralization and blowdown processing subsystem:

A.

Maintain the purity and chemistry of the condensate, feedwater, and steam generator secondary side water.

When feeding the steam generators, the chemistry of the main feed train shall be in accordance with subsection 10.3.5.

B.

Be capable of continuously purifying the full condensate flow. Full flow condensate demineralization systems shall be capable of continuous operation with 1 ppm total dissolved solids in the influent.

C.

Continuously purify and recycle the steam generator blowdown. Blowdown flow for each steam generator may be used to maintain the steam generator chemistry within the limits outlined in subsection 10.3.5.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-30 Revision 14 D.

In order to minimize the consequences of a blowdown line rupture, each steam generator shall be equipped with an independent blowdown line.

10.4.6.1.2 Chemical Monitoring and Addition Design Bases The following design bases apply to the chemical monitoring and addition subsystem:

A.

Continuously monitor significant secondary side chemical parameters and alarm any fault conditions.

B.

Continuously add volatile chemicals to the secondary side water to maintain pH and oxygen levels within the specified limits.

C.

Inject boric acid into the secondary system as needed to mitigate denting and intergrannular attack/stress corrosion cracking (IGA/SCC) in the SGs.

D.

Add chemicals to the feed train and steam generators prior to wet layup to minimize corrosion during long outages.

10.4.6.2 System Description and Operation 10.4.6.2.1 Condensate Demineralization A full flow condensate demineralization subsystem capable of continuous service maintains feedwater purity during startup and periods of condenser leakage. In the condensate demineralizers, dissolved solids are removed by ion exchange, and suspended solids are removed by filtration.

The Condensate demineralization subsystem is comprised of six mixed bed ion exchangers in the hydrogen-hydroxide form. The

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-31 Revision 14 demineralizers are normally in standby unless condenser leakage dictates that they be in service. If full flow service is needed, five of the demineralizers are required to be in service to support full power (approximately 26,000 gallons per minute), leaving one vessel in standby where it is available when one of the other beds becomes exhausted. This extra vessel allows the system to remain in continuous operation without reducing the process capability. The effluent from each condensate demineralizer is continuously monitored for conductivity and specific ions. This will assure that the quality of the effluent is within the specified limits for feedwater (subsection 10.3.5).

The condensate demineralizer subsystem is designed to have sufficient capacity to continuously process condensate contaminated by small condenser leaks, and will permit an orderly shutdown if a larger leak occurs. The size of the leak that is able to be tolerated will depend partly on the pH at which the secondary system is being maintained. It takes approximately 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to perform a regeneration of both the cation and anion resin. The secondary pH may be lowered slightly to allow sufficient time to perform full regenerations if the condenser leakrate exceeds the capacity of the resin to maintain acceptable effluent chemistry.

The operation of the CDS during plant startup is described in paragraph 10.4.6.2.5.

In order to ensure that a condensate demineralizer is always on standby, and to minimize the possibility of introducing regenerant chemicals into the feed train, the exhausted resin from the condensate demineralizers is externally regenerated.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2009 10.4-32 Revision 15 Resin regeneration is performed in one of the two modes:

  • Full regeneration, including backwash, anion resin chemical regeneration, and cation resin chemical regeneration
  • Partial regeneration, including backwash and cation resin chemical regeneration.

Wastes produced by resin regeneration are minimized by reusing those which are acceptably low in TDS. Low TDS rinse water is recycled to the condenser hotwell. Low TDS regenerant waste is recycled to the circulating water system for use in condenser cooling. Condensate polisher Pre-Service Rinse water can be diverted directly to the Retention Tank for ultimate onsite disposal. High TDS regenerant waste is unacceptable for reuse and is processed through the chemical waste system. From here the waste is sent either to the retention tank for ultimate onsite disposal or, if radioactivity exceeds the release limits stated in the Offsite Dose Calculation Manual (ODCM), to the liquid radwaste system for further processing and eventual recycle.

10.4.6.2.2 Steam Generator Blowdown Processing Steam generator blowdown controls the concentration of impurities in the steam generator secondary side water. Each steam generator will be equipped with its own blowdown processing line with the capability of blowing down either the primary inlet or primary outlet regions of the steam generator. In addition to a hot leg blowdown line, the steam generators are also equipped with a blowdown line that allows blowdown from the downcomer region, and an additional downcomber blowdown line.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2009 10.4-33 Revision 15 The blowdown will be directed into a flash tank operating at 225 psig where the flashed steam is returned to the cycle via the heater drain tanks. The liquid portion then flows to a heat exchanger where it is cooled by condensate to 140F (Blowdown Demineralizer in use) or 165F (Blowdown Demineralizer bypassed).

It is then directed through a blowdown filter where the major portion of the suspended solids are removed. It can also be directed to the retention tank for ultimate onsite disposal.

After filtration, the blowdown fluid is processed by the blowdown demineralizer or directed straight to the condenser hotwell (Blowdown Demineralizer bypassed).

In the event of malfunction of the blowdown processing equipment, the flow can be directed to the condenser, thus maintaining the steam generator chemistry. During this mode of operation, the condensate polishing demineralizers would be placed in service.

10.4.6.2.3 Chemical Monitoring The chemical monitoring subsystem is designed to provide continuous indication of significant chemical parameters in the secondary system and to alert the operator of faulty chemistry or equipment malfunction. Continuous online samples are taken from each section of the main condenser, the condensate demineralizer system inlet and outlet, the main feed lines, and the steam generator blowdown lines or downcomer sample, feedwater lines, and circulating water lines.

Samples taken from each section of the main condenser are analyzed for sodium ion concentration and intensified conductivity. Besides providing indications of condenser tube

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-34 Revision 14 leakage, these monitors can be used in locating the section of the condenser that is leaking.

Upon indication of a condenser tube leak by the sampling system, the condensate polishing demineralizer may be placed into service and the polishing demineralizer bypass valve closed. The condensate polishers will handle a maximum circulating water inleakage of 1 gallon per minute on a continuous basis. If this leakage is exceeded, the affected condenser hotwell half may be isolated by motor-operated valves in the condensate pump suction and discharge lines. The remaining condenser hotwell storage and the makeup rate will provide enough condensate for reduction to 50% power by utilizing a 10% step and then a 5% per minute ramp down to a 50% power level. The respective circulating water path is isolated and the condenser half is drained. The leaking tubes can be plugged and the contaminated hotwell can be pumped out by one condensate pump to the condenser circulating water outlet.

Leakage from the condensate demineralizers will allow contaminants to enter the steam generators (SGs). To detect for this possibility, the condensate demineralizers' influent and effluent will be monitored. Sodium, specific conductivity, cation conductivity, sulfates, and chlorides will be measured on the demineralizer effluent.

Hydrazine monitors are used to measure the hydrazine content in the main feed lines.

The main feed lines will be analyzed for pH, and samples taken from the steam generator blowdown lines are monitored for pH, conductivity, and radiation. Continuous pH measurements will ensure that the specified alkaline conditions exist in the

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2009 10.4-35 Revision 15 system. This will ensure an alkaline environment which minimizes corrosion. Conductivity measurements on the steam generator blowdown will verify that dissolved solids are not concentrating in the steam generators. A steam generator sample is measured for radioactivity in order to detect primary to secondary leakage.

10.4.6.2.4 Chemical Addition The function of the chemical addition subsystem is to establish and maintain the proper chemistry within the condensate, feedwater, and steam generator secondary side water. During normal operation, volatile chemicals are added to the feed train downstream of the condensate demineralizers. These additives serve to control the pH, establish a reducing environment, and to scavenge any dissolved oxygen. In addition, the chemical addition subsystem is also used to provide the proper chemical environment during wet layup.

Since these additives are volatile, they will not concentrate in the steam generators. This characteristic is desirable for several reasons. First, the concentration of solids in the steam generators will be minimized. This will lessen the dangers associated with solids attack of Inconel 690. In addition, the volatile nature of these additives will allow for some corrosion protection throughout the steam system. This is especially important in protecting the large metal surface areas of the feedwater heater shells.

A pH controlling additive, usually ammonia, is used to raise the feedwater pH to within normal limits. This pH range is effective in slowing the corrosion rate of carbon steel.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-36 Revision 14 Continuous ammonia additions are required during operations because the volatile ammonia will be scrubbed from the condensing steam in the air removal section of the main condenser or be removed by the condensate demineralizers if it redissolves in the condensate.

An inventory of a reducing agent/oxygen scavenger, usually hydrazine, is maintained in the feed train as a means of scavenging dissolved oxygen and to ensure a reducing environment is maintained in the steam generators. Hydrazine also contributes to the formation of an adherent metal oxide film on system surfaces that reduces corrosion product release. Ammonia is a by-product of Hydrazine once it volatilizes.

Boric acid, a non-volatile chemical, may be injected into the secondary system for mitigating denting and Intergranular Attack/Stress Corrosion Cracking (IGA/SCC) in the steam generator. Boric acid reduces pH in the steam generator crevices by reacting with sodium hydroxide (NaOH) to form a borate complex. Also, boric acid dilutes the hydroxide (OH

-)

concentration, thereby lowering the chemical activity and reducing the probability that OH

- is present at the actively corroding grain boundary of the steam generator crevices. The small affect that boric acid has on lowering the secondary plant pH can be offset by increasing the pH controlling chemical additive.

Chemical additions necessary for wet layup will be accomplished through the use of the auxiliary feedwater system. The chemical additions will be made at the suction of the non-Seismic Category I auxiliary feed pump. This will ensure that

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-37 Revision 14 each steam generator receives adequate protection during long outages.

Chemical additions are typically made by metering pumps, two high-pressure and four low-pressure. The high-pressure pumps inject into the steam generator main feedwater, one pump taking hydrazine from the two hydrazine tanks and the other taking ammonia from the two ammonia tanks. The low-pressure pumps inject hydrazine and ammonia to the demineralized condensate, blowdown condensate, or auxiliary feedwater. The low-pressure pumps are duplicated.

10.4.6.2.5 System Operation During Plant Startup While the secondary plant is in a cold shutdown condition, it is possible for air to enter the system. Use of nitrogen blankets and a reducing agent/oxygen scavenger, such as hydrazine will minimize, but not eliminate, the corrosion of metal surfaces. This corrosion results in loose oxide layers being formed on the surfaces of the feed train. Before returning to power, it is necessary to reduce the concentration of the reducing agent/oxygen scavenger in the secondary system, remove the corrosion products generated during layup, and reduce the dissolved oxygen concentration to within the normal operating specifications.

Reduction in the reducing agent/oxygen scavenger concentration is accomplished by draining the steam generators and refilling them with auxiliary feedwater containing the correct hydrazine concentration. In addition, the draining of the steam generators serves to remove any suspended solids which might be present in the generators.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-38 Revision 14 Once the steam generators have been refilled with water, the primary plant temperature will be raised and the steam generators warmed up.

Next, feed train recirculation is started by initiating flow through the presteam generator cleanup line.

The concentration of suspended solids is reduced by draining a portion of the circulating flow prior to entering the hotwell or by circulating through the condensate demineralizers. Make-up at a rate of approximately 500 gallons per minute is supplied from the condensate storage tank.

Oxygen will be removed from the recirculating feedwater by using the vacuum that has been established in the main condenser. Since the feedwater has been heated to 175F, a condenser vacuum to 6 inches of Hg (abs) is sufficient to remove dissolved oxygen from the feedwater.

Once main feed has been initiated, the reactor power can be increased.

10.4.6.3 Safety Evaluation The secondary chemistry control system serves no safety-related functions. Therefore, no safety evaluation is performed.

Each of the steam generator blowdown lines is equipped with two remotely operated containment isolation valves that automatically close on a main steam isolation signal (MSIS),

auxiliary feedwater actuation signal (AFAS), or safety injection actuation signal (SIAS).

The sample lines from the steam generator blowdown lines are each equipped with two remotely operated containment isolation valves which automatically close on an AFAS, MSIS, or SIAS.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-39 Revision 14 10.4.6.4 Tests and Inspections Preoperational testing will include a test of the system instrumentation. Automatic control features will be tested to ensure proper operation. Piping, valves, and components will be checked for proper installation. Pumps will be tested for head and capacity. Valves will be operated and checked for function. The system will be operated automatically to ensure that the system will function as designed. Heat exchangers will be checked for proper performance and flow rates adjusted where necessary to establish proper conditions.

During normal plant operations, testing, inspection, and calibration will be conducted on a regular schedule to ensure proper system operation. Data taken during operating periods will be used to evaluate the performance of the secondary chemistry control system.

10.4.6.5 Instrumentation Requirements Flow and conductivity of the demineralized condensate are continuously recorded.

Local instrumentation is provided for the demineralizer regeneration system including temperature control of the dilute caustic and level control of acid and rinse tanks.

Conductivity of the demineralized condensate is recorded continuously. Local conductivity indication is provided for the resin regenerant solutions and rinses.

Local instrumentation is provided for the chemical addition and monitoring subsystem. The sampling instruments are protected from a high temperature sample by a bypass valve operated by a temperature controller.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-40 Revision 14 10.4.7 CONDENSATE AND FEEDWATER SYSTEM The condensate and feedwater system provides heated feedwater to the steam generators. The system has the capability of maintaining the proper feedwater inventory in the steam generator during startup and normal operation.

10.4.7.1 Design Bases 10.4.7.1.1 Safety Design Bases Pertinent safety design bases are as follows:

A.

Safety Design Basis One The feedwater lines are designed so that failure in this piping will have minimal effects on the reactor coolant pressure boundary (RCPB).

B.

Safety Design Basis Two The feedwater lines are designed so that the failure of any feedwater supply piping will not prevent safe shutdown of the reactor.

C.

Safety Design Basis Three The containment feedwater isolation valves and piping from the valves to the steam generator nozzles are designed to withstand the effects of a safe shutdown earthquake (SSE).

D.

Safety Design Basis Four Components and piping shall be designed, protected from, or located to protect against the effects of high and moderate energy pipe rupture, whip, and jet impingement.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-41 Revision 16 E.

Safety Design Basis Five This system will be designed such that adverse environ-mental conditions such as tornados, floods, and earthquakes will not impair its safety function.

F.

Safety Design Basis Six The loss of offsite power to the system will not pre-vent the safe shutdown of the reactor.

10.4.7.1.2 Power Generation Design Bases Power generation design bases applicable to this system are as follows:

A.

Power Generation Design Basis One The condensate and feedwater system is designed to provide feedwater to the steam generator at the required temperature and pressure during all phases of operation.

B.

Power Generation Design Basis Two Extraction lines and feedwater heaters are designed to minimize the possibility of water slug induction to the main turbine and to limit main turbine overspeed due to entrained energy in the extraction system.

10.4.7.1.3 Codes and Standards Components of the condensate and feedwater systems are designed and constructed in accordance with the applicable codes and standards identified in table 3.2-1.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-42 Revision 16 10.4.7.2 System Description The condensate and feedwater system is shown schematically on engineering drawings 01, 02, 03-M-CDP-001, -002, -003, -004 and 01, 02, 03-M-FWP-001. The condensate and feedwater system supplies the steam generators with heated feedwater in a closed steam cycle using regenerative feedwater heating. The main turbine cycle heat balance at guaranteed load is given in section 10.1. Extraction steam is covered in subsection 10.2.2.

The main condenser hotwells receive condensate makeup from the condensate tank. Refer to subsection 9.2.6 for a discussion of the condensate storage system.

The main portion of the feedwater flow is deaerated condensate pumped from the main condenser hotwells by the condensate pumps.

This stream passes in sequence through the condensate cleanup system; the three trains of low-pressure heaters, each train consisting of No. 1, No. 2, No. 3, and No. 4 low-pressure heaters; the steam generator feedwater pumps; the two trains of high-pressure heaters, each train consisting of No. 5, No. 6, and No. 7 high-pressure heaters; control and isolation valves; and on into the two steam generators of the NSSS. The balance of the feedwater flow is provided by the drains from the moisture separator reheaters and No. 7, No. 6, and No. 5 heaters that are collected into a drain tank and pumped into the feedwater pump suction stream by the heater drain pumps.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2009 10.4-43 Revision 15 To allow feedwater and condensate system startup recirculation, a cleanup system called "long path recirculation" is provided.

This system allows condensate from the hotwell to be pumped by a condensate pump through all major feedwater/condensate piping and components up to the economizer crosstie line. From this point the recirculation flow is returned to the hotwell. The system is sized to allow a flow velocity of up to 2 ft/sec in the largest portion of the main flow path, thereby ensuring shearing and entrainment of pipe scale and other system impurities. A drain connection is provided upstream of the return nozzle to the hotwell.

In addition to the long path recirculation system, a connection to the shell side of a low-pressure feedwater heater from the auxiliary boiler is provided. This connection is capable of admitting sufficient steam to raise the feedwater temperature to 175F.

Transients within the condensate and feedwater system that affect the final feedwater temperature or flow have a direct effect on the RCS. Occurrences that produce an increase in feedwater flow or a decrease in feedwater temperature result in excessive heat removal from the RCS, which is compensated for by control system action as described in section 7.7. These occurrences are considered in section 15.1 in conjunction with the failure of compensatory control actions, and are shown to be safely terminated by the reactor protective system. Events that produce the opposite effect; i.e., decreased feedwater flow or increased feedwater temperature, result in reduced heat transfer in the steam generators. Normally, automatic control system action is available to adjust feedwater flow and reactor power to prevent excess energy accumulation in the RCS, and the

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-44 Revision 16 increasing reactor coolant temperature provides a negative reactivity feedback that tends to reduce reactor power. In the absence of control action, the high outlet temperature and high-pressure trips of the reactor protective system are available to assure reactor safety. Loss of all feedwater, the most severe transient of this type, is examined in section 15.2.

Nitrogen accumulators are provided on the feedwater control and isolation valves in the feedwater line to the steam generator downcomer nozzle. These accumulators allow the operator to remotely operate these valves without normal instrument air.

In conjunction with the non-Seismic Category I auxiliary feedwater pump described in subsection 10.4.9, this provides a third flow path for auxiliary feedwater to the steam generators. This use of the non-essential AFS train is provided to improve the overall availability of the AFS system and is not required for Chapters 6 and 15 accident mitigation.

10.4.7.2.1 Component Description Refer to table 10.4-5 for design data.

10.4.7.2.1.1 Condensate Pumps. The condensate pumps are motor-driven, of the vertical mixed-flow type, and operate in parallel. Valving is provided to allow removal of individual pumps and maintain system operability.

10.4.7.2.1.2 Condensate Cleanup System. Refer to subsection 10.4.6 for a discussion of the condensate cleanup system.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-45 Revision 14 Table 10.4-5 MAIN FEEDWATER/CONDENSATE SYSTEM REQUIREMENTS FOR MAJOR COMPONENTS DESIGN DATA Equipment Number Capacity Condensate pumps 3

50%

No. 1 to No. 4 4/train 33%/train feedwater heaters 3 trains Steam generator feedwater 2

65%

pumps No. 5, No. 6, and No. 7 HP 3/train 50%/train (a) feedwater heaters 2 trains Heater drain tank 1/train 50%/train 2 trains Heater drain pumps 1/train 50%/train 2 trains

a.

Approximately 40%/train and 20% bypass in feedwater temperature reduction mode of full power operation.

10.4.7.2.1.3 Low-Pressure Feedwater Heaters. The low-pressure heaters are of the closed type and are installed in the main condenser necks. Low-pressure feedwater heaters have integral drain coolers. The No. 4 drains to No. 3 heater, No.

3 drains to No. 2, and No. 2 drains to No. 1 and from there to the main condenser. The condensate, after passing from the main condenser through the low-pressure heaters (three trains),

is routed to a header and fed to the steam generator feedwater pumps.

Low-pressure feedwater heaters have main condenser drain lines to allow direct discharge to the main condenser.

10.4.7.2.1.4 Feedwater Pumps. The feedwater pumps operate in parallel and discharge to the high-pressure feedwater heaters.

The pumps take suction from the No. 4 low-pressure feedwater heaters of the three parallel low-pressure heater trains and

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-46 Revision 14 discharge through the two parallel trains of high-pressure feedwater heaters. Each pump is turbine-driven with independent variable speed control units. Steam for the turbines is supplied from the main steam header at low loads, and from the hot reheat line during normal operation.

Isolation valves are provided to allow each steam generator feedwater pump to be individually removed from service, while continuing operations at reduced capacity with the parallel pump.

10.4.7.2.1.5 High-Pressure Feedwater Heaters. The feedwater system contains two parallel trains of high-pressure feedwater heaters. High-pressure feedwater heaters Nos. 6 and 7 are provided with integral drain coolers. High-pressure heater No.

7 drains to high-pressure heater No. 6. High-pressure heaters Nos. 6 and 5 drain to the high-pressure heater train drain tank.

Isolation valves and bypasses are provided to allow each train of high-pressure heaters to be removed from service. System operability is maintained with the remaining train. The bypass line may also be used in conjunction with flow through both heater trains when operating the plant in the feedwater temperature reduction mode of full power operation.

Provisions are made in heater drain lines to allow direct discharge to the main condenser.

10.4.7.2.1.6 Heater Drain Tank. A single heater drain tank for each high-pressure heater train receives the drains from the shells of high-pressure feedwater heater Nos. 5 and 6 and moisture separator reheater drain tank and provides reservoir

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-47 Revision 14 capacity for drain pumping into the feed pump suction header.

Each high-pressure heater train drain tank is installed beneath the No. 5 feedwater heater so that high-pressure heaters drain freely. The drain level is maintained within the train drain tank by a level controller in conjunction with the heater drain pump discharge flow control valve.

The high-pressure heater train drain tank is provided with an alternate drain line to the main condenser for automatic dumping upon high level. The alternate drain line also is used during startup and shutdown when it is desirable to bypass the drain pumping for feedwater quality purposes.

10.4.7.2.1.7 Heater Drain Pumps. The high-pressure heater drain pumps operate in parallel, each taking suction from its high-pressure heater train drain tank and discharging to the suction header of the feedwater pumps. Each high-pressure heater drain tank pump is a motor-driven, multistage, centrifugal pump located below the heater drain tank and is designed for the available suction conditions.

10.4.7.2.1.8 Pump Recirculation Systems. Minimum flow control systems are provided to allow all pumps in the main condensate and feedwater trains to operate at a sufficient rate to prevent damage.

10.4.7.2.1.9 Containment Feedwater Line Isolation Valves.

The containment feedwater isolation valves discussed in subsection 6.2.4 are designed to isolate the feedwater system from the steam generator in the event of a steam line break, feedwater line break, or loss-of-coolant accident (LOCA). This isolation precludes any possibility of radioactivity release

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-48 Revision 16 from the containment due to a condensate or feedwater pipe break.

The isolation valves in the feedwater line to the steam generator downcomer nozzle are provided with nitrogen accumulator to allow manual remote control with a loss of offsite power to supply auxiliary feedwater to the steam generators from the non-Seismic Category I auxiliary feedwater pump described in subsection 10.4.9. Note that the backup nitrogen accumulator for the feedwater control and isolation valves was not credited during a normal loss of offsite power event.

10.4.7.2.2 System Operation 10.4.7.2.2.1 Prestartup Feedwater Cleanup Procedure. The condensate pumps circulate condensate from the condenser hot-wells, through the condensate cleanup system, through all feedwater heater trains through the recirculation valve, and back to the hotwell. This procedure is repeated until the condensate cleanup system has yielded feedwater quality equivalent to that specified in section 10.3.5.

10.4.7.2.2.2 Power Generation Operation. Feedwater is sup-plied to the steam generator from the steam generator feedwater pumps. Feedwater flow is controlled through the main feedwater control valves that establish steam generator feedwater balancing in conjunction with the variable speed feedwater pump turbine drives. The feedwater system may be operated either with the high pressure feedwater bypass valve open or closed in conjunction with both feedwater heater trains being in service.

When the plant is operated at the licensed reactor power with the bypass valve closed, additional plant thermal efficiencies are achieved. When the plant is operated at the licensed

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-49 Revision 16 reactor power with the bypass valve open in the feedwater temperature reduction mode, both plant thermal efficiencies and steam generator thermal stresses are reduced. Extended operation in either configuration is within the system and plant design and licensing basis.

10.4.7.3 Safety Evaluation Safety evaluations, numbered to correspond to the safety design bases, are as follows:

A.

Safety Evaluation One The main feedwater lines are restrained or are separated to the extent necessary to prevent damage to the RCPB in the event of a feedwater pipe rupture.

Refer to section 3.6 for additional discussion on this subject.

B.

Safety Evaluation Two Main feedwater lines are designed and routed so that a failure will not prevent a safe shutdown of the reactor. Refer to section 3.6 for information on this subject.

C.

Safety Evaluation Three The containment feedwater isolation valves and piping between them and the steam generators are designed to meet Seismic Category I criteria in accordance with requirements given in sections 3.7 and 3.9.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-50 Revision 16 D.

Safety Evaluation Four Components and piping are designed to protect against the effects of high and moderate energy pipe rupture as discussed in section 3.6.

E.

Safety Evaluation Five Adverse environmental conditions do not impair the safety function of this system. Wind and tornado loadings are discussed in section 3.3. Flood design is covered in section 3.4. Seismic design is discussed in section 3.7.

F.

Safety Evaluation Six The loss of offsite power does not prevent the safe shutdown of the reactor as discussed in sections 7.4 and 8.3.

10.4.7.4 Tests and Inspections ASME Code,Section III, Class 2, piping is inspected and tested in accordance with ASME Code, Sections III and XI and the ASME OM Code. ANSI B31.1.0 piping is inspected and tested in accordance with Paragraphs 136 and 137. ASME Code,Section III, Class 2, valves are periodically inservice-tested for exercising and leakage in accordance with ASME OM Code.

Isolation valves, vent and drain valves, and test connections required in the system to effect these tests are included in engineering drawings 01, 02, 03-M-CDP-001, -002, -003, -004 and 01, 02, 03-M-FWP-001.

Each feedwater heater, heater drain tank, pump, and valve is shop-tested by hydrostatic pressure tests performed in accordance with applicable codes. Tube joints of feedwater

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-51 Revision 16 heaters are shop leak-tested. Prior to initial operation, the completed condensate and feedwater system receives a field hydrostatic test and inspection in accordance with the applicable code. Periodic tests and inspections of the system are performed in conjunction with scheduled maintenance outages. In addition, PVNGS agrees to perform a steam generated feedwater water hammer test in accordance with NUREG/CR-1606. PVNGS will perform the test according to a standard operating procedure (SOP). PVNGS will run the plant at approximately 15% of full power by using feedwater through the downcomer nozzle. The feedwater will then be switched from the downcomer nozzle to the economizer nozzle and the following transient will be observed and recorded. Inservice inspections are not required unless there is an indication of malfunction somewhere in the system.

10.4.7.5 Instrumentation Applications Feedwater flow control instrumentation measures the feedwater flowrate from the condensate and feedwater system. This flow measurement, transmitted to the feedwater control system, regulates the feedwater flow to the steam generators to meet system demands. Refer to section 7.7 for a description of the feedwater control system.

Instrumentation and controls are provided for regulating mini-mum pump flowrates for the condensate pumps, high-pressure heater drain pumps, and steam generator feedwater pumps.

Sampling means are provided for monitoring the quality of the final feedwater, as described in subsection 10.4.6.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-52 Revision 16 In the feedwater heating portion of the system, temperature measurements are provided for each stage of heating. These measurements include the temperature into and out of each feedwater heater for the water side and out of each heater for the steam side of the system except that steam temperature is determined by its saturation pressure in feedwater heater Nos.

1, 2, 3, and 4. Steam pressure measurements are provided at each feedwater heater. Liquid pressure measurements are provided at appropriate locations throughout the system.

Instrumentation and controls are provided to maintain the proper condensate level in the feedwater heater or heater drain tank. High level alarm and automatic dump action on high level also are provided.

Appropriate instrumentation displays and alarms are provided in the control room.

10.4.8 STEAM GENERATOR BLOWDOWN SYSTEM The steam generator blowdown system is an integral part of the secondary chemistry control system of the condensate cleanup system, and is discussed in subsection 10.4.6.

10.4.8.1 CESSAR Interface Requirements Refer to subsection 5.1.4.

10.4.8.2 CESSAR Interface Evaluations Refer to subsection 5.1.5.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-53 Revision 14 10.4.9 AUXILIARY FEEDWATER SYSTEM The auxiliary feedwater system (AFS) is designed to provide steam generator feedwater during startup, hot standby, normal shutdown, and emergency conditions.

The AFS reliability analysis (formally appendix 10B) has been archived as historical information only in PVNGS engineering calculation 13-NC-AF-200, "Auxiliary Feedwater System (AFS)

Reliability Analysis." Refer to appendix 5A, Question 5A.17, for additional discussion.

10.4.9.1 Design Bases 10.4.9.1.1 Safety Design Bases The following safety design bases are applicable to the essential portions of the AFS only:

A.

Safety Design Basis One The AFS shall provide feedwater for the removal of decay heat from the RCS following reactor shutdown from any power level until such time as cooling by the shutdown cooling system may be initiated.

B.

Safety Design Basis Two One motor-driven AFS pump and one steam turbine-driven AFS pump and associated valves and piping shall be designed to Seismic Category I requirements. In addition, the isolation valves and piping connections to this Seismic Category I piping shall be designed to Seismic Category I requirements.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-54 Revision 14 C.

Safety Design Basis Three The turbine-driven Seismic Category I AFS pump shall be available in the event of a loss of all ac power.

D.

Safety Design Basis Four The Seismic Category I motor-driven AFS pump and its associated power-operated valves shall be connected to one onsite (diesel generator) power bus as discussed in subsection 8.3.1. In addition, the turbine-driven AFS pump's turbine control system and its associated power-driven valves are connected to the dc power system as discussed in subsection 8.3.2.

E.

Safety Design Basis Five Redundancy shall be provided throughout the AFS and supporting systems to ensure the supply of feedwater to either or both steam generators in the event of an accident plus one active failure.

F.

Safety Design Basis Six The AFS shall be designed to maintain water level in the steam generators under the following operating modes and accident conditions:

1.

Reactor coolant system cooldown at a maximum rate of 75F per hour from hot standby to a temperature of 350F with a loss of offsite power and normal onsite power.

2.

Hot standby for 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> with a loss of offsite power and normal onsite power.

3.

Reactor coolant system cooldown using the intact steam generator following a main steam line break

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-55 Revision 14 or main feedwater line break inside the containment with a loss of offsite power and normal onsite power.

G.

Safety Design Basis Seven Each of the two Seismic Category I AFS pumps shall be designed to provide 100% of the required flow (see Table 10.4-6) for decay heat removal. The head generated by each pump is sufficient to deliver feedwater into the steam generators at 1270 psia or equivalent at the entrance of the steam generators.

H.

Safety Design Basis Eight In the unlikely event that the control room must be evacuated, the AFS shall be capable of being operated for shutdown from a remote shutdown station.

I.

Safety Design Basis Nine The Seismic Category I, motor-driven AFS pump shall be located in a separate room designed to Seismic Category I requirements in the main steam support structure. The Seismic Category I, steam turbine-driven AFS pump shall also be located in a separate room designed to Seismic Category I requirements in the main steam support structure.

J.

Safety Design Basis Ten The components, including piping for each AFS pump safety train, shall be separated from each other and are either enclosed by a Seismic Category I structure or installed underground.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-56 Revision 14 K.

Safety Design Basis Eleven The combination of motor-driven and steam turbine-driven pumps shall provide diversity of power sources to assure delivery of feedwater under an emergency condition.

L.

Safety Design Basis Twelve All components and piping shall be designed, protected from, or located to protect against the effects of high and moderate energy pipe rupture, pipe whip, and jet impingement.

M.

Safety Design Basis Thirteen This system shall be designed such that adverse environmental conditions such as tornados, floods, and earthquakes will not impair its safety function.

10.4.9.1.2 Power Generation Design Basis The non-Seismic Category I, motor-driven AFS pump is used as the feedwater pump during startup, hot standby, and normal shutdown conditions.

10.4.9.1.3 CESSAR Interface Requirements Refer to subsection 5.1.4.

10.4.9.1.4 CESSAR Interface Evaluation Refer to subsection 5.1.5.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-57 Revision 14 10.4.9.1.5 Codes and Standards The AFS is designed to codes and standards identified in table 3.2-1.

10.4.9.1.6 Reliability/Availability Bases The bases contained within this section represent the major design features of the non-essential AFS train which were added to improve the original AFS design from a reliability/availability perspective or are major assumptions which have been credited in performing risk related analyses for PVNGS. These bases reflect the most relevant features of the non-essential AFS train design from a reliability/availability perspective and are not intended to be all encompassing. The PVNGS Individual Plant Examination (IPE) provides a complete description of the reliability/availability assessments that were completed for the AFS. The following bases are only applicable to the non-essential AFS trains:

A. Reliability/Availability Bases One The non-essential AFS train is not required to perform a safety function for the mitigation of the design basis accidents presented in Chapters 6 and 15. The emergency operating procedures provide instructions for using the non-essential AFS train, if available, in addition to the essential AFS trains as a defense-in-depth measure that assists in mitigating plant events. The non-essential AFS train is not required to mitigate accidents, but provides additional reliability/availability to the AFS. Risk related analyses shall consider operator actions (including human errors) in assessing the reliability or availability of the AFS.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-58 Revision 14 B. Reliability/Availability Bases Two The following bases have been credited in the risk assessments performed on the non-essential portion of the AFS as part of the IPE:

1.

The non-Seismic Category I AFS pump minimum flow recirculation path back to the condensate storage tank does not need to be isolated to meet the IPE performance as described in Table 10.4-6, note c. In addition, the IPE does not require the flow path to remain open in situations where the minimum flow requirements for the pump are met with the minimum flow path isolated.

2.

Periodic full-flow testing of the non-Seismic Category I AFS pump is not required.

3.

The downcomer feedwater isolation valves are designed to fail open on a loss of power.

4.

The backup nitrogen accumulator for the downcomer feedwater control and isolation valves was not credited during a normal loss of offsite power event.

5.

The AFS flow to the steam generators is controlled in accordance with the standard post trip actions as defined in the emergency operating procedures (see Table 10.4-6, note c, for IPE credited performance for the AFS pumps).

C. Reliability/Availability Bases Three The AFS overall reliability is enhanced by including the non-essential AFS pump in each unit's Technical Specifications.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-59 Revision 14 D. Reliability/Availability Bases Four The non-Seismic Category I motor driven AFS pump and associated power-operated valves shall have the capability to be powered by the Train A diesel generator when connected by manual action to the load group 1 bus as described in Section 8.3.1. The non-Seismic Category I motor driven AFS pump may be controlled from the main control room.

E. Reliability/Availability Bases Five The non-Seismic Category I motor driven AFS pump is located within the Turbine Building. This structure and the non-essential AFS train components contained within this structure are not designed to withstand adverse environmental conditions resulting from earthquakes, tornadoes, floods or hazards for which the essential AFS trains are required to be designed to withstand.

F. Reliability/Availability Bases Six The design and performance requirements for the non-Seismic Category I motor driven AFS pump are provided in Table 10.4-6.

10.4.9.2 System Description 10.4.9.2.1 General Description The AFS consists of one Seismic Category I, motor-driven AFS pump; one Seismic Category I, steam turbine-driven AFS pump; and one non-Seismic Category I, motor-driven AFS pump, associated piping, controls, and instrumentation. Engineering drawings 01, 02, 03-M-AFP-001 show the piping and instrumentation diagram of the system.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-60 Revision 14 The primary source of auxiliary feedwater is the condensate storage tank. The condensate storage tank provides a reserve capacity (see Table 9.2-21) for the AFS during emergency shutdown conditions. This provides an orderly RCS cooldown to shutdown cooling initiation conditions as addressed in safety design basis six of paragraph 10.4.9.1.1 and provides sufficient feedwater to maintain the plant as hot standby for 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

Both motor-driven auxiliary feedwater pumps and their motor-operated valves can receive power from both onsite and offsite power sources. In the event of a loss of offsite power, power is supplied to these motor-driven pumps by their standby diesel generators. The Seismic Category I, motor-driven pump and its motor-operated valves are connected to the train B power source by automatic initiation or by operator action. The non-Seismic Category I pump and its valves can be connected to the train A power source by operator action only. The two Seismic Category I auxiliary feedwater pumps are separated by a physical barrier.

Piping and components for the Seismic Category I pumps are located, separated, or protected to preclude damage from any missile effects.

The turbine-driven AFS pump is supplied with steam from the main steam lines of either steam generator upstream of the main steam isolation valves. The turbine controls and associated valves are powered from the dc bus.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-61 Revision 14 10.4.9.2.2 Component Description Principal components are listed in table 10.4-6.

10.4.9.2.3 System Operation For emergency operation, normal flow is from the condensate tank to either the Seismic Category I, motor-driven AFS pump or to the steam turbine-driven, Seismic Category I AFS pump which are located in the main steam support structure. An alternate supply of water is provided by cross-connections to the reactor makeup tank.

A minimum flow recirculation system is provided on each pump discharge with recirculation to the condensate tank and supports pump testing. Each pump can supply either steam generator with feedwater.

One auxiliary feedwater path to the steam generators is provided for the non-Seismic Category I, motor-driven auxiliary feedwater pump through the feedwater header, with manual operation of feedwater valves possible during emergency operation. This feature of the non-essential AFS train is provided to improve the overall availability of the AFS system and is not required for Chapters 6 and 15 accident mitigation.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-62 Revision 14 Table 10.4-6 AUXILIARY FEEDWATER SYSTEM DESIGN DATA Design Factor Value Notes Auxiliary feedwater pumps Quantity Motor-driven, non-Seismic Category I 1

Motor-driven, Seismic Category I 1

Steam turbine-driven, Seismic Category I 1

Flow, Seismic Category I, gal/min, net 750 a, b Miniflow, Seismic Category I, gal/min, maximum 260 b

Flow, non-Seismic Category I, gal/min, net 710 a, c Miniflow, non-Seismic Category I, gal/min, maximum 300 c

Head, ft - Seismic Category I at 750 gal/min plus 260 gal/min miniflow 3,280 b

Head, ft - non-Seismic Category I at 710 gal/min plus 300 gal/min miniflow 2,960 c

a. Net flow delivered to steam generators.
b. The values shown are for the design performance specifications of the auxiliary feedwater pumps. The safety analysis credits delivery of 650 gpm at a steam generator pressure of 1270 psia or equivalent at the steam generator entrance for design basis accidents.
c. The values shown in this Table are based on the design performance specifications for the non-Seismic Category I AFS pump. The power generation design bases for this pump assumes a minimum performance of 650 gpm delivered to the steam generator(s) at a design no load pressure of 1170 psia. The IPE credits a AFS flow of approximately 500 gpm to the steam generator(s) when steam generator conditions are maintained in accordance with the standard post trip actions as defined in the emergency operating procedures.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-63 Revision 14 The two Seismic Category I auxiliary feedwater pumps only provide flow to the downcomer feedwater nozzles on each steam generator. Either Seismic Category I auxiliary feedwater pump can supply the necessary feedwater for reactor decay heat removal and reactor cooldown to 350F.

At a reactor coolant temperature of 350F, the shutdown cooling system is placed in operation.

A minimum flow path is provided for each pump. Approximately 26% of the Seismic Category I pump capacity and 30% of the non-Seismic Category I pump capacity is recirculated back to the condensate tank whenever a pump is operating. The minimum flow line is provided to prevent pump overheating in the event the pump discharge line is isolated.

The Seismic Category I pump motor driver is powered from a separate engineered safety features (ESF) bus which is powered by the load group 2 diesel generator. The Seismic Category I, steam turbine-driven pump's associated valving is powered from the dc bus as discussed in subsection 8.3.2. The turbine for this pump is supplied with steam from either of the steam generators. The turbine controls are powered from the dc bus.

Auxiliary feedwater control for the essential trains is normally from the control room, but instrumentation is provided for operation from the remote shutdown panel in the unlikely event that the control room must be evacuated.

Signals from the auxiliary feedwater actuation signal (AFAS) start the Seismic Category I, motor-driven auxiliary feedwater pump and the Seismic Category I, steam turbine-driven auxiliary feedwater pump, shut all steam generators' blowdown and blowdown sample isolation valves, and open the associated isolation

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-64 Revision 14 valves to the downcomer nozzles of the intact steam generator(s). The non-Seismic Category I, motor-driven pump is started manually and its associated valves are opened manually from the control room.

Assuming a pipe break in either steam generator lower feedwater supply line in the containment, a single electrical failure will not prevent the system from accomplishing its function.

Either Seismic Category I pump can supply the flow required for safe shutdown. Table 10.4-7 lists the Seismic Category I valves in the AFS.

10.4.9.3 Safety Evaluation Safety evaluations, numbered to correspond to the safety design bases, are as follows:

A.

Safety Evaluation One The AFS, in conjunction with the condensate tank described in subsection 9.2.6, provides a means of pumping feedwater to maintain the plant at hot standby for 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, with a subsequent cooldown at a maximum rate of 75F per hour to a reactor coolant temperature of 350F.

B.

Safety Evaluation Two The two Seismic Category I AFS pumps and their associated valves and piping are designed to Seismic Category I requirements. The isolation valves and piping connections to the Seismic Category I piping are also designed to Seismic Category I requirements.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-65 Revision 14 C.

Safety Evaluation Three During normal operation, the two Seismic Category I AFS pumps are each available in the event of loss of off-site power and normal onsite power.

D.

Safety Evaluation Four The Seismic Category I, motor-driven AFS pump and its associated line valves are connected to the load group 2 onsite power bus as discussed in subsection 8.3.1. The turbine-driven AFS pump control system and the associated line valves are connected to the dc power system as discussed in subsection 8.3.2.

E.

Safety Evaluation Five Redundancy is provided throughout the AFS and associated systems to ensure the supply of feedwater to either or both steam generators in the event of an accident plus one active failure. Table 10.4-8 presents a single failure analysis for the AFS.

F.

Safety Evaluation Six The AFS is designed to maintain an adequate water level in the steam generators under the following operating modes and accident conditions:

1.

Reactor cooldown at a maximum administratively controlled rate of 75F per hour from hot standby to 350F with a loss of offsite power and normal onsite power.

2.

Hot standby for 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> with a loss of offsite power and normal onsite power.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-66 Revision 14

3.

Reactor coolant system cooldown using the intact steam generator following a main steam line break or main feedwater line break inside the containment with a loss of offsite power and normal onsite power.

Table 10.4-7 SEISMIC CATEGORY I VALVES IN MAJOR FLOW PATHS FOR THE AUXILIARY FEEDWATER SYSTEM (a) (Sheet 1 of 5)

Valves Actu-Valve Valve Valve

Size, ator Classifi-No.

Service Description Type Inches Type cation (b)

V002 Main steam to AFW PP A turbine isolation Gate 6

None N

valve V005 AFW PP A suction check valve from reactor Check 8

None A

makeup water tank V006 AFW PP A suction isolation valve from Gate 8

None N

condensate storage tank V007 AFW PP A suction check valve from Check 8

None A

condensate storage tank V009 AFW PP B suction check valve from reactor Check 8

None A

makeup water tank V015 AFW PP A discharge check valve after Check 6

None A

recirculation V016 AFW PP A discharge isolation valve after Gate 6

None N

recirculation V017 AFW PP A miniflow recirculation Gate 3

None N

V021 AFW PP B suction isolation valve from Gate 8

None N

condensate storage tank June 2007 10.4-67 Revision 14 PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM

Table 10.4-7 SEISMIC CATEGORY I VALVES IN MAJOR FLOW PATHS FOR THE AUXILIARY FEEDWATER SYSTEM (a) (Sheet 2 of 5)

Valves Actu-Valve Valve Valve Size, ator Classifi-No.

Service Description Type Inches Type cation (b)

V022 AFW PP B suction check valve from Check 8

None A

condensate storage tank V024 AFW PP B discharge check valve after Check 6

None A

recirculation line V025 AFW PP B discharge isolation valve Gate 6

None N

(manual)

V026 AFW PP B miniflow recirculation valve Gate 3

None N

V028 AFW PP B suction isolation valve from Gate 8

None N

reactor makeup water tank HV30 AFW regulating valve PP B to SG 1 Globe 6

Motor A

HV31 AFW regulating valve PP B to SG 2 Globe 6

Motor A

HV32 AFW regulating valve PP A to SG 1 Globe 6

Motor A

HV33 AFW regulating valve PP A to SG 2 Globe 6

Motor A

UV34 AFW isolation valve PP B to SG 1 Gate 6

Motor A

UV35 AFW isolation valve PP B to SG 2 Gate 6

Motor A

UV36 AFW isolation valve PP A to SG 1 Gate 6

Motor A

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-68 Revision 14

Table 10.4-7 SEISMIC CATEGORY I VALVES IN MAJOR FLOW PATHS FOR THE AUXILIARY FEEDWATER SYSTEM (a) (Sheet 3 of 5)

Valves Actu-Valve Valve Valve Size, ator Classifi-No.

Service Description Type Inches Type cation (b)

UV37 AFW isolation valve PP A to SG 2 Gate 6

Motor A

HV54 AFW turbine steam trip and throttle Globe 4

Motor A

valve VO55 AFW turbine auxiliary steam isolation Gate 4

None N

valve VO58 AFW PP A reactor makeup water tank Gate 8

None N

isolation valve VO77 (c)

AFW PP A recirculation isolation valve Gate 6

None N

to condensate tank VO78 (c)

AFW PP B recirculation isolation valve Gate 6

None N

to condensate tank VO79 AFW check valve to SG 1 FW header Check 6

None A

(in-containment)

VO80 AFW check valve to SG 2 FW header Check 6

None A

(in-containment)

VO96 Auxiliary steam check valve to AFW Check 4

None N

turbine June 2007 10.4-69 Revision 14 PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM

Table 10.4-7 SEISMIC CATEGORY I VALVES IN MAJOR FLOW PATHS FOR THE AUXILIARY FEEDWATER SYSTEM (a) (Sheet 4 of 5)

Valves Valve Valve Valve

Size, Actuator Classifi-No.

Service Description Type Inches Type cation (b)

V137 AFW PP A discharge check valve before Check 6

None A

recirculation V138 AFW PP B discharge check valve before Check 6

None A

recirculation UV134 (d) SG 1 steam supply to AFW PP turbine Gate 6

Motor A

UV138 (d)

SG 1 steam supply to AFW PP turbine Gate 6

Motor A

UV134A (d) SG 1 steam bypass to AFW PP turbine Globe 1.5 Motor A

UV138A (d) SG 2 steam bypass to AFW PP turbine Globe 1.5 Motor A

V234 (d)

SG 1 steam bypass line isolation valve for Globe 2

(f)

None N

UV134A V238 (d)

SG 2 steam bypass line isolation valve for Globe 2

(f)

None N

UV138A V885 (d)

SG 1 steam bypass isolation valve to AFW PP Globe 2

None N

turbine V886 (d)

SG 2 steam bypass isolation valve to AFW PP Globe 2

None N

turbine V887 (d)

SG 1 steam bypass check valve to AFW PP Check 2

None A

turbine V888 (d)

SG 2 steam bypass check valve to AFW PP Check 2

None A

turbine PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2009 10.4-70 Revision 15

Table 10.4-7 SEISMIC CATEGORY I VALVES IN MAJOR FLOW PATHS FOR THE AUXILIARY FEEDWATER SYSTEM (a) (Sheet 5 of 5)

Valves Valve Valve Valve

Size, Actuator Classifi-No.

Service Description Type Inches Type cation (b)

V889 (d)

Steam bypass to AFW PP turbine isolation valve Globe 2

None N

V043 (d)

SG 1 steam check valve to AFW PP turbine Check 6

None A

V044 (d)

SG 2 steam check valve to AFW PP turbine Check 6

None A

V994 (e)

SG 2 FW recirculation isolation valve Gate 4

None N

V995 (e)

SG 2 FW recirculation isolation valve Gate 4

None N

V996 (e)

SG 1 FW recirculation isolation valve Gate 4

None N

V997 (e)

SG 1 FW recirculation isolation valve Gate 4

None N

a. Seismic Category I valves listed below are omitted from the list:

Instrument isolation valves Vent valves Drain valves AFW PP turbine cooling subsystem valves AFW PP bearing cooling and gland seal injection subsystem valves

b. A = active; N = nonactive; Note that A and N are related to the components movement during performance of its safety function and not to the application of single failure criteria.
c. Valves in AFW system shown in condensate transfer and storage system (CT)
d. Valves in AFW system shown in main steam system (SG)
e. Valves isolate downcomer feedwater (an AFW flow path) from recirculation lines.
f. Valve size in Unit 2 is 11/2 inches PVNGS UPDATED FSAR OTHER FEATURES OF STEAM June 2011 10.4-71 Revision 16

Table 10.4-8 SINGLE FAILURE MODE ANALYSIS--AUXILIARY FEEDWATER SYSTEM (Sheet 1 of 2)

Inherent Compensating Component Failure Mode/Cause Effects on System Method of Detection Provision Remarks Isolation valve to Fails closed/

Loss of secondary Valve stem Redundant lines from reactor makeup mechanical failure source of water position condensate tank water tank or inadvertent for the auxiliary misposition feedwater pumps Fails open/

None Valve stem Valve is normally mechanical failure position closed.

or inadvertent misposition Check valves from Fails closed/corrosion None None Redundant lines Only used in case reactor makeup available to condensate tank water tank condensate tank not available.

Fails open/

None None contamination Isolation valves to Fails closed/

None Handle position Redundant line Valve is normally condensate tank mechanical binding available from locked open.

condensate tank Fails open/locking None Handle position None Valve is locked mechanism jams open.

Check valves from Fails closed/corrosion None None Redundant line condensate tank available from condensate tank Fails open/

None None contamination Auxiliary feedwater Fails to pump/

No effect on system Low pressure Redundant 100%

pump (Seismic mechanical performance indication capacity Seismic Category I) electrical failure from pump Category I auxiliary feedwater pump available. A 100%

capacity non-Seismic Category I pump is also available PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-72 Revision 14

Table 10.4-8 SINGLE FAILURE MODE ANALYSIS--AUXILIARY FEEDWATER SYSTEM (Sheet 2 of 2)

Inherent Compensating Component Failure Mode/Cause Effects on System Method of Detection Provision Remarks Pump discharge Fails closed/

Loss of one aux-High-pressure indi-Redundant 100% capacity check valves corrosion iliary feed-cation from pump auxiliary feedwater water pump pump available.

Fails open/

No effect other None contamination than causing trouble if maintenance of valve is required while system is operating.

Discharge valves, Fails open/

None Handle position Valve is normally auxiliary feed-mechanical or locked open water pumps electrical failure Fails closed/

Effective loss of Handle position Redundant 100% capacity Valve is normally mechanical one auxiliary auxiliary feedwater locked open binding feedwater pump pump Isolation valves to Fails open/

Loss of double Valve position Redundant valves feedwater header mechanical or isolation indicator in electrical between the control room failure main feedwater supply and auxiliary feedwater supply to one steam generator Fails closed/

Slight decrease Valve position None required mechanical or in flexibility indicator in electrical of feedwater control room failure system Check valves to Fails open/

No serious effect Periodic test None required feedwater contamination header Fails closed/

Slight decrease Periodic test None requried corrosion in flexibility of feedwater system Overpressure Relief Valves for Outboard AF Containment Isolation Valves Fails open/

mechanical failure Fails closed/

mechanical failure or corrosion Slight decrease in amount of water delivered to Steam Generator(s)

Effective loss of one auxiliary feedwater pump Periodic test Periodic test Both auxiliary feedwater pumps remain available such that their total combined Technical Specification required flow is met.

Redundant 100% capacity auxiliary feedwater pump FW recirculation isolation valve (a)

Fails open/inadvertent position None Handle position Redundant valve Valves are locked closed and administratively controlled

a.

Valves isolate downcomer feedwater (an AFW flow path) from recirculation lines.

June 2009 10.4-73 Revision 15 PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-74 Revision 14 Only the Seismic Category I pumps are started on an AFAS.

The Seismic Category I AFS pumps are not routinely used for normal plant operations. The non-Seismic Category I AFS pump is utilized for startup, hot standby and normal shutdown of the plant.

G.

Safety Evaluation Seven Each of the essential AFS pumps is capable of delivering 650 net gallons per minute at 1270 psia or equivalent at the entrance of the steam generator.

H.

Safety Evaluation Eight The AFS can be operated from either the control room or from a remote shutdown station.

I.

Safety Evaluation Nine Each Seismic Category I AFS pump is installed in a separate room designed to Seismic Category I requirements. These rooms are in the main steam support structure.

J.

Safety Evaluation Ten The components and piping for each Seismic Category I AFS pump train are separated from each other in that no credible hazard within either train pump room can affect both trains. Where complete physical separation is not met as a result of design constraints, separation criteria are satisfied because sufficient protection is provided to assure an inherently reliable and safe design configuration which ensures essential AFS train redundancy. In general, the components and piping of both Seismic

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-75 Revision 14 Category I AFS trains are either enclosed by a Seismic Category I structure or are installed underground. Those components and piping of both Seismic Category I AFS trains which are not contained within a Seismic Category I structure or installed underground (e.g., portions of the AFS recirculation lines and AFS Turbine Exhaust Stack), have been analyzed to show that the probability of being struck by a tornado missile postulated in section 3.5, is sufficiently low (<10

-7 per year) to not be a credible event for the design basis of the AFS and do not require tornado missile protection.

K.

Safety Evaluation Eleven The combination of the one Seismic Category I, motor-driven pump and the one Seismic Category I, steam turbine-driven pump utilizes a diversity of power sources to assure delivery of feedwater under emergency conditions.

L.

Safety Evaluation Twelve All components and piping are designed to protect against the effects of high and moderate energy pipe ruptures as discussed in section 3.6.

M.

Safety Evaluation Thirteen Adverse environmental conditions will not impair the safety function of this system. Wind and tornado loadings are discussed in section 3.3. Flood design is covered in section 3.4. Seismic design is discussed in section 3.7.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2011 10.4-76 Revision 16 10.4.9.4 Inspection and Testing Requirements The system is capable of being tested while the plant is in normal operation. Each of the essential and non-essential AFS pumps is provided with a minimum flow recirculation line back to the condensate storage tank. This line ensures that the minimum flow requirements for each pump are met and allows for periodic testing required by the applicable codes that are identified in Section 3.9.6. This design allows the AFS to be operationally tested up to the steam generator auxiliary feedwater isolation valves. Full flow testing of the essential AFS pumps is performed in accordance with the Technical Specifications.

These tests ensure the operability of the essential AFS by taking a supply from the condensate storage tank and injecting auxiliary feedwater into the steam generators. Successful performance of these full flow tests ensure that the essential AFS meets the minimum performance requirements credited in the safety analyses (Table 10.4-6, note b) for Chapter 6 and 15 events. Full flow testing of the non-essential AFS pump is not required to be performed since this pump is not credited in the safety analyses for Chapter 6 and 15 events.

Power Operated Containment isolation valves can be tested by either remote or local operation during normal plant operation.

The system is inspected as required by the applicable codes as identified in table 3.2-1.

Temperature monitoring of both the Seismic Category I and Non-Seismic Category I Auxiliary Feedwater pump is conducted in accordance with the recommendations of Generic Letter 88-03, Steam Binding of Auxiliary Feedwater Pumps.

PVNGS UPDATED FSAR OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM June 2007 10.4-77 Revision 14 10.4.9.5 Instrumentation Requirements Instrumentation and controls are provided as described in paragraph 10.4.9.3. Control room instrumentation includes auxiliary feedwater flow and pump discharge pressure, steam generator level, control hand switches, and position indication for all power-operated valves, and auxiliary feedwater pump, turbine speed control, and indication.

Control logic for the AFS is addressed in section 7.3.

This page intentionally blank

PVNGS UPDATED FSAR APPENDIX 10A RESPONSES TO NRC REQUESTS FOR INFORMATION

PVNGS UPDATED FSAR

PVNGS UPDATED FSAR June 2001 10A-i Revision 11 CONTENTS Page Question 10A.1 (NRC Question 430.37) (10.1) 10A-1 Question 10A.2 (NRC Question 430.38) (10.2) 10A-1 Question 10A.3 (NRC Question 430.39) (10.2) 10A-2 Question 10A.4 (NRC Question 430.40) (10.2) 10A-3 Question 10A.5 (NRC Question 430.41) (10.2) 10A-3 Question 10A.6 (NRC Question 430.42) (10.2) 10A-4 Question 10A.7 (NRC Question 430.43) (10.2) 10A-4 Question 10A.8 (NRC Question 430.44) (10.2) 10A-5 Question 1OA.9 (NRC Question 430.45) (10.3) 10A-5 Question 10A.10 (NRC Question 430.46) (10.4.1) 10A-7 Question 10A.11 (NRC Question 430.47) (10.4.1) 10A-8 Question 10A.12 (NRC Question 430.48) (10.4.1) 10A-8 Question 1OA.13 (NRC Question 430.49) (10.4.1) 10A-8 Question 10A.14 (NRC Question 430.50) (10.4.1) 10A-9 Question 10A.15 (NRC Question 430.51) (10.4.1) 10A-9 Question 10A.16 (NRC Question 430.52) (10.4.1) 10A-9 Question 10A.17 (NRC Question 430.53) (10.4.4) 10A-10 Question 10A.18 (NRC Question 430.54) (10.4.4) 10A-10 Question 10A.19 (NRC Question 430.55) (10.4.4) 10A-10 Question 10A.20 (NRC Question 430.56) (10.4.4) 10A-11 Question 10A.21 (NRC Question 282.2) (10.3.5) 10A-11 Question 10A.22 (NRC Question 410.25) (10.3) 10A-14 Question 10A.23 (NRC Question 410.26) (10.4.5) 10A-14 Question 10A.24 (NRC Question 410.27) (10.4.7) 10A-14

PVNGS UPDATED FSAR

PVNGS UPDATED FSAR June 2001 10A-1 Revision 11 QUESTION 10A.1 (NRC Question 430.37)

(10.1)

Provide a general discussion of the criteria and bases of the various steam and condensate instrumentation systems in sec-tion 10.1 of the FSAR. The FSAR should differentiate between normal operation instrumentation and required safety instrumentation.

RESPONSE: The response is given in subsection 10.1.3 and amended paragraph 10.4.9.5.

QUESTION 10A.2 (NRC Question 430.38)

(10.2)

Expand your discussion of the turbine speed control and over-speed protection system. Provide additional explanation of the turbine and generator electrical load following capability for the turbine speed control system with the aid of system schematics (including turbine control and extraction steam valves to the heaters). Tabulate the individual speed control protection devices (normal emergency and backup), the design speed (or range of speed) at which each device begins operation to perform its protective function (in terms of percent of normal turbine operating speed). In order to evaluate the adequacy of the control and overspeed protection system provide schematics and include identifying numbers to valves and mechanisms (mechanical and electrical) on the schematics. Describe in detail, with references to the identifying numbers, and sequence of events in the turbine trip including response times, and show that the turbine stabilizes. Provide the results of a failure mode and effects analysis for the overspeed protection systems. Show that a single steam valve failure cannot disable the turbine overspeed trip from functioning. (SRP 10.2, Part III, Items 1, 2, 3, and 4).

PVNGS UPDATED FSAR June 2001 10A-2 Revision 11 RESPONSE: Expanded discussion of turbine speed control and overspeed protection system is given in amended subsec-tion 10.2.2 and table 10.2-3.

QUESTION 10A.3 (NRC Question 430.39)

(10.2)

The FSAR discusses the main steam stop and control, and reheat stop and intercept valves. Show that a single failure of any of the above valves cannot disable the turbine overspeed trip functions. (SRP 10.2, Part III, Item 3).

RESPONSE: The turbine overspeed protection system is an equipment protection system and is not required for plant safety.

Nevertheless, as described below and in section 10.2, the turbine overspeed protection system provides a highly reliable system to trip the turbine in the event of a tur-bine overspeed condition.

The function of the turbine overspeed trip sensors is to provide signals to the turbine trip system which, in turn, actuates the solenoid valves in the emergency trip systems.

The emergency trip actuates the disk dump valve for each stop, control, reheat stop, and intercept valve to depres-surize hydraulic fluid in trip system. This allows spring to close the valves to terminate the flow of steam to the turbine.

Each of the main steam and reheat lines supplying steam to the high-pressure and low-pressure cylinders of the turbine has two valves (stop and control) in series. Failure of one valve to close will not prevent tripping the turbine since the second valve in the same line will close, thus terminating the flow of steam to the turbine.

PVNGS UPDATED FSAR June 2001 10A-3 Revision 11 (Figure 10.1-1, sheet 1, indicates the approximate location of the turbine main steam stop, control, reheat stop, and intercept valves.)

QUESTION 10A.4 (NRC Question 430.40)

(10.2)

Expand your discussion of the inservice inspection program for throttle-stop, control, reheat stop, and interceptor steam valves to include inspection times and the capability for test-ing essential components during turbine generator system operation. (SRP 10.2, Part III, Items 5 and 6).

RESPONSE: The response is given in amended paragraph 10.2.3.6.

QUESTION 10A.5 (NRC Question 430.41)

(10.2)

Discuss the effects of a high and moderate energy piping fail-ure or failure of the connection from the low pressure turbine to condenser on nearby safety-related equipment or systems.

Discuss what protection will be provided the turbine overspeed control system equipment, electrical wiring, and hydraulic lines from the effects of a high or moderate energy pipe failure so that the turbine overspeed protection system will not be damaged to preclude its safety function. (SRP 10.2 Part III, Item 8).

RESPONSE: High and moderate energy piping failure within the turbine building, or failure of the connection between the low-pressure turbine to the condenser will not adversely affect plant safety since there is no safety-related equip-ment located within the turbine building. Further response is given in paragraph 3.6.1.2. The turbine overspeed protection system is for equipment protection only.

PVNGS UPDATED FSAR June 2001 10A-4 Revision 11 Nevertheless, the turbine overspeed protection system pro-vides a highly reliable system to trip the turbine in event of a turbine overspeed condition. Aside from providing two redundant channels of speed control, two additional means of overspeed protection are provided as discussed in paragraph 10.2.2.3.1.5. Because of the redundancy in the mode of operation and the physical separation of components, a high or moderate energy pipe failure will not preclude protective function of the turbine overspeed control system.

QUESTION 10A.6 (NRC Question 430.42)

(10.2)

In paragraph 10.2.3.6 you discuss inservice inspection and exercising of the main steam turbine stop and control and reheater stop and intercept valves. You do not discuss the inservice inspection, testing and exercising of the extraction steam valves. Provide a detail description of: 1) the extrac-tion steam valves, and 2) your inservice inspection and testing program for these valves. Also provide the time interval between periodic valve exercising to assure the extraction steam valves will close on turbine trip.

RESPONSE: The extraction steam valves are described in amended paragraph 10.2.2.5.

QUESTION 10A.7 (NRC Question 430.43)

(10.2)

Describe with the aid of drawings, the bulk hydrogen storage facility including its location and distribution system.

Include the protective measures considered in the design to prevent fires and explosions during operations such as filling and purging the generator, as well as during normal operations.

PVNGS UPDATED FSAR June 2001 10A-5 Revision 11 RESPONSE: The following drawings (sent under separate cover) show the location of the bulk hydrogen storage facilities and the hydrogen distribution system:

13-P-ZYA-958, Rev. 0 13-M-GAP-001, Rev. 4 01-C-ZVC-305, Rev. 7 13-M-GAP-002, Rev. 2 01-C-CVC-306, Rev. 7 13-M-GHP-001, Rev. 4 13-P-GAF-201, Rev. 4 13-M-CHP-002, Rev. 6 13-P-GAF-401, Rev. 2 13-P-CHF-218, Rev. 5 13-P-ZYA-015, Rev. 6 Further response is given in paragraph 9.3.6.2.2.

QUESTION 10A.8 (NRC Question 430.44)

(10.2)

Paragraph 10.2.1.3 references the CESSAR turbine generator interface requirements of subsections 5.1.4 and 7.2.3 The CESSAR FSAR sections 5.1.4 and 7.2.3 do not contain any turbine generator interface requirements. Clarify this inconsistency, provide the CESSAR interface requirements and an evaluation of how you are meeting those requirements.

RESPONSE: The response is given in amended paragraph 10.2.1.3.

QUESTION 10A.9 (NRC Question 430.45)

(10.3)

As explained in issue No. 1 of NUREG-0138, credit is taken for all valves downstream of the main steam isolation valve (MSIV) to limit blowdown of a second steam generator in the event of a steam line break upstream of the MSIV. In order to confirm satisfactory performance following such a steam line break pro-vide a tabulation and descriptive text (as appropriate) in the

PVNGS UPDATED FSAR June 2001 10A-6 Revision 11 FSAR of all flow paths that branch off the main steam lines between the MSIVs and the turbine stop valves. For each flow path originating at the main steam lines, provide the following information:

a) System identification b) Maximum steam flow in pounds per hour c) Type of shutoff valve(s) d) Size of valve(s) e) Quality of the valve(s) f) Design code of the valve(s) g) Closure time of the valve(s) h) Actuation mechanism of the valve(s) (i.e., solenoid-operated, motor-operated, air-operated diaphragm valve, etc.)

i) Motive or power source for the valve actuating mechanism In the event of the postulated accident, termination of steam flow from all systems identified above, except those that can be used for mitigation of the accident, is required to bring the reactor to a safe cold shutdown. For these systems describe what design features have been incorporated to assure closure of the steam shutoff valve(s). Describe what operator actions (if any) are required.

If the systems that can be used for mitigation of the accident are not available or decision is made to use other means to shut down the reactor describe how these systems are secured to assure positive steam shutoff. Describe what operator actions (if any) are required.

PVNGS UPDATED FSAR June 2003 10A-7 Revision 12 If any of the requested information is presently included in the FSAR text, provide only the references where the information may be found.

RESPONSE: NUREG-0138 page 1-9 states that the probability of occurrence of the above scenario is quite low. Page 1-10 states that the scenario is not analyzed by the staff and need not be considered as a design basis accident. This scenario should, therefore, not be a design basis accident for Palo Verde Units 1, 2, and 3.

Refer to the following P&IDs:

  • 13-M-SGP-001
  • 13-M-SGP-002
  • 13-M-FTP-001
  • 13-M-CDP-001
  • 13-M-MTP-001
  • 13-M-MTP-002
  • 13-M-ASP-001
  • 13-M-GSP-001 Further response is given in paragraph 10.3.2.2.2.

QUESTION 10A.10 (NRC Question 430.46)

(10.4.1)

Provide a tabulation in your FSAR showing the physical characteristics and performance requirements of the main condensers.

In your tabulation include such items as: 1) the number of condenser tubes, material and total heat transfer surface, 2) overall dimensions of the condenser, 3) number of passes, 4) hot

PVNGS UPDATED FSAR June 2001 10A-8 Revision 11 well capacity, 5) special design features, 6) minimum heat transfer, 7) normal and maximum steam flows, 8) normal and maximum cooling water temperature, 9) normal and maximum exhaust steam temperature with no turbine bypass flow and with maximum turbine bypass flow, 10) limiting oxygen content in the condensate in cc per liter, and 11) other pertinent data.

(SRP 10.4.1, Part III, Item 1).

RESPONSE: The response is given in amended paragraph 10.4.2.2 (table 10.4-1).

QUESTION 10A.11 (NRC Question 430.47)

(10.4.1)

Discuss the measures taken; 1) to prevent loss of vacuum, and

2) to prevent corrosion/erosion of condenser tubes and compo-nents. (SRP 10.4.1, Part III, Item 1).

RESPONSE

The response is given in paragraph 10.4.1.2.

QUESTION 10A.12 (NRC Question 430.48)

(10.4.l)

Indicate and describe the means of detecting and controlling radioactive leakage into and out of the condenser and the means for processing excessive amounts. (SRP 10.4.1, Part III, Item 2).

RESPONSE: The response is given in paragraphs 10.4.5.2, 11.3.3.4, and 11.5.2.1.3.2, and subsection 10.4.6.

QUESTION 10A.13 (NRC Question 430.49)

(10.4.1)

Discuss the measures taken for detecting, controlling and cor-recting condenser cooling water leakage into the condensate stream. (SRP 10.4.1, Part III, Item 2)

RESPONSE: The response is given in amended paragraph 10.4.6.2.3.

PVNGS UPDATED FSAR June 2001 10A-9 Revision 11 QUESTION 10A.14 (NRC Question 430.50)

(10.4.1)

In paragraph 10.4.1.4 you have discussed tests and initial field inspection but not the frequency and extent of inservice inspec-tion of the main condenser. Provide this information in the FSAR (SRP 10.4.1, Part II).

RESPONSE: The response is given in amended paragraph 10.4.1.4.

QUESTION 10A.15 (NRC Question 430.51)

(10.4.1)

Indicate what design provisions have been made to preclude failures of condenser tubes or components from turbine bypass blowdown or other high temperature drains into the condenser shell (SRP 10.4.1, Part III, Item 3).

RESPONSE: The condenser and its tubes are protected from turbine bypass blowdown steam flow by a manifold having two stages of pressure reduction orifices that direct the steam flow away from the condenser tubes.

Further response is given in paragraph 10.4.1.2.

QUESTION 10A.16 (NRC Question 430.52 (10.4.1)

Discuss the effect of loss of main condenser vacuum on the operation of the main steam isolation valves (SRP 10.4.1, Part III, item 3).

RESPONSE: As discussed in subsection 10.4.1, the main condenser has no safety function. However, the main steam isolation valves will shut indirectly because of loss of main condenser vacuum as explained in paragraph 15.2.2.1.

PVNGS UPDATED FSAR June 2003 10A-10 Revision 12 QUESTION 10A.17 (NRC Question 430.53)

(10.4.4)

Provide additional description (with the aid of drawings) of the turbine bypass valves and associated instrumentation and controls. In your discussion include the number, size, principle of operation, construction, setpoints, and capacity of each valve and the malfunctions and/or modes of failure considered in the design of the turbine bypass system.

(SRP 10.4.4, Part III, Item 1.)

RESPONSE: The response is given in subsection 10.4.4 and section 7.7, figure 10.4-1, CESSAR Sections 10.4.4 and 7.7.1.1.5, and CESSAR Figure 7.7-6.

QUESTION 10A.18 (NRC Question 430.54)

(10.4.4)

Provide the results of an analysis indicating that failure of the turbine bypass system high energy line will not have an adverse effect or preclude operation of the turbine speed control system or any safety-related components or systems located close to the turbine bypass system. (SRP 10.4.4, Part III, Item 4).

RESPONSE: See response to Question 10A.5 (NRC Ques-tion 430.41.)

QUESTION 10A.19 (NRC Question 430.55)

(10.4.4)

In paragraph 10.4.4.4 you have discussed tests and initial field inspection but not the frequency and extent of inservice testing and inspection of the turbine bypass system. Provide this information in the FSAR. (SRP 10.4.4, Part II).

RESPONSE: The response is given in amended paragraph 10.4.4.3, listing B.

PVNGS UPDATED FSAR June 2001 10A-11 Revision 11 QUESTION 10A.20 (NRC Question 430.56)

(10.4.4)

Subsection 10.4.4 of your FSAR refers to Section 10.4.4 of CESSAR for additional discussion of the turbine bypass system. Your turbine bypass system differs from the one discussed in CESSAR, in that two of your bypass valves dump to atmosphere while in CESSAR they do not. Provide a discussion to show that your system meets the 11 design bases stated in Section 10.4.4.1 of CESSAR.

RESPONSE: The response is given in amended subsection 10.4.4.

QUESTION 10A.21 (NRC Question 282.2)

(10.3.5)

Provide the steam generator secondary water chemistry control and monitoring program, addressing the following:

1.

Sampling schedule for the critical parameters and of control points for these parameters for each mode of operation: normal operation, hot startup, cold startup, hot shutdown, cold wet layup; 2.

Procedures used to measure the values of the critical parameters; 3.

Process sampling points; 4.

Procedure for the recording and management of data; 5.

Procedures defining corrective actions (a) for off-control point chemistry conditions; and 6.

The procedure identifying (a) the authority responsible for the interpretation of the data and (b) the sequence and timing of administrative events required to initiate corrective action.

PVNGS UPDATED FSAR June 2001 10A-12 Revision 11 Verify that the steam generator secondary water chemistry control program incorporates technical recommendations of the NSSS. Any significant deviations from NSSS recommendations should be noted and justified technically.

In addition to the secondary water chemistry monitoring and control program, we require monitoring of the steam condensate at the effluent of the condensate pump. The monitoring of the condensate is for the purpose of detecting condenser leakage.

RESPONSE: (Item numbers correspond to those of the question.)

1.

The response is given in paragraph 10.3.5.1.

a.

Branch Technical Position MTEB 5-3 describes the acceptable means for monitoring secondary side water chemistry in PWR steam generators, including corrective actions for off-control point chemistry conditions. However, the staff is amenable to alternatives, particularly to Branch Technical Position B.3.b(9) of MTEB 5-3 (96-hour time limit to repair or plug confirmed condenser tube leaks).

PVNGS UPDATED FSAR June 2001 10A-13 Revision 11 2.

Procedures for measuring the values of critical parameters will reflect C-E technical recommendations or exceptions will be technically justified in subsection 10.3.5.

The following industry procedures reflect the most recent C-E technical recommendations for measuring the respective parameters.

Parameter Procedure pH ASTM, Part 31, Procedure D1293, Method B Conductivity ASTM, Part 31, Procedure D1125, Method B Suspended Solids Standard Methods, Procedure 208D or ASTM, Part 31, Procedure D1888 Silica ASTM, Part 31, D859, Method B 3.

Process sampling points are listed in paragraph 10.4.6.2.3.

4.

The response is given in paragraph 10.3.5.1.

5.

The response is given in paragraph 10.3.5.1.

6.

The response is given in paragraph 10.3.5.1.

The steam generator secondary water chemistry control program is described in paragraph 10.3.5.1, which reflects C-E's technical recommendations. Technical recommendations are met by the existing design. There are no significant deviations from NSSS steam generator chemistry recommendations.

PVNGS UPDATED FSAR June 2001 10A-14 Revision 11 Paragraph 10.4.6.2.3 describes the method of continuously monitoring for indication of condenser leaks, which is to continuously monitor each section of the condenser hotwell, instead of monitoring condenser pump discharge.

QUESTION 10A.22 (NRC Question 410.25)

(10.3)

In order to prevent blowdown of more than one steam generator, verify that the main steam isolation valves are designed to stop full main steam flow at the maximum design differential pressure in both directions in the event of a main steam line break in one steam line upstream of an MSIV and corresponding single failure (to close) in an MSIV to the other steam generator.

RESPONSE: The response is given in subsection 10.3.2.2.2.

QUESTION 10A.23 (NRC Question 410.26)

(10.4.5)

The evaluation of potential flooding of essential plant areas as a result of a circulating water system failure indicates that the water level would eventually reach plant grade at which point the water leaves the turbine building. Verify that this water can not enter safety-related structures through openings at grade or describe the protection provided for safety-related equipment from such an occurrence.

RESPONSE: The response is given in paragraph 10.4.5.2.

QUESTION 10A.24 (NRC Question 410.27)

(10.4.7)

It is our position that you commit to perform a steam generator/feedwater water hammer test in accordance with the guidance for preheat type steam generators as identified in NUREG/CR-1606, "An Evaluation of Condensation-Induced Water Hammer in Preheat Steam Generators." The following procedure should be followed:

PVNGS UPDATED FSAR June 2001 10A-15 Revision 11 "Run the plant at approximately 15% of full power by using feedwater through the downcomer nozzle at the lowest feedwater temperature that the plant Standard Operating Procedure (SOP) allows. Switch the feedwater at that temperature from the downcomer nozzle to the economizer nozzle by following the SOP.

Observe and record the transient that follows."

RESPONSE: The response is given in paragraph 10.4.7.4.

Intentionally Left Blank

PVNGS UPDATED FSAR June 2001 Revision 11 APPENDIX 10B (DELETED)

Intentionally Left Blank