Letter Sequence Other |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement
Results
Other: ML110620203, ML11140A163, ML11172A096, ML11224A265, ML11230A003, ML11305A075, ML11318A121, ML11318A122, ML11318A123, ML11318A124, ML11318A125, ML11318A126, ML11318A127, ML11318A128, ML11318A129, ML11318A130, ML11318A131, ML11318A132, ML11318A133, ML11318A135, ML11318A136, ML11318A138, ML11318A139, ML11318A140, ML11318A141, ML11318A142, ML11318A143, ML11318A144, ML11318A145, ML11318A146, ML11318A147, ML11318A148, ML11318A149, ML11318A150, ML11318A151, ML11318A152, ML11318A153, ML11318A154, ML11318A155, ML11318A156, ML11318A157, ML11318A158, ML11318A159, ML11318A160, ML11318A161, ML11318A162, ML11318A163, ML11318A164, ML11318A165, ML11318A166... further results
|
MONTHYEARML1106202032011-03-17017 March 2011 License Renewal Application Online Reference Portal Project stage: Other ML1108309782011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application, Fire Protection and Component Integrity (TAC Nos. ME4536 ME4637 Project stage: RAI ML1108907642011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application-Electrical Branch Scoping Project stage: RAI ML1108205792011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application -Section 2.4 Structural Project stage: RAI ML1112501472011-05-0505 May 2011 Notice of Withdrawal of Megan Wright in the Matter of South Texas Project, Units 1 and 2 Project stage: Request ML11130A0262011-05-0505 May 2011 Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI ML11145A0902011-05-12012 May 2011 Response to Request for Additional Information for Licence Renewal Application Project stage: Response to RAI ML11137A0922011-05-24024 May 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application Future Consideration of Operating Experience Project stage: RAI ML11140A1632011-06-0606 June 2011 Plan for the Aging Management Program Regulatory Audit Regarding the South Texas Project, Units 1 and 2 License Renewal Application Review Project stage: Other ML11172A0962011-06-16016 June 2011 Amendment 2 to the License Renewal Application Project stage: Other NOC-AE-11002681, Amendment 2 to the License Renewal Application2011-06-16016 June 2011 Amendment 2 to the License Renewal Application Project stage: Other ML11181A0372011-06-23023 June 2011 Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI NOC-AE-11002683, Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937)2011-06-23023 June 2011 Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Response to RAI ML11154A0132011-07-0606 July 2011 Summary of Telephone Conference Call Held on May 23, 2011, Between the NRC and STPNOC, Concerning Requests for Additional Information Pertaining to the South Texas Project, LRA-Future Consideration of Operating Experience Project stage: RAI ML11166A2392011-07-12012 July 2011 Letter Request for Additional Information for South Texas Project Electric Generating Station, Units 1 and 2 License Renewal Application - Scoping and Screening Balance of Plant Project stage: RAI ML11201A0552011-07-28028 July 2011 Requests for Additional Information for the Review of the South Texas Project, License Renewal Application - Scoping and Screening Audit Project stage: RAI NOC-AE-11002702, Response to Request for Additional Information for the Review of the South Texas Project License Renewal Application2011-08-0909 August 2011 Response to Request for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: Response to RAI ML11234A0452011-08-0909 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application Project stage: Response to RAI ML11245A1012011-08-0909 August 2011 Response to Request for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: Response to RAI ML11214A0052011-08-15015 August 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Programs Audit, Structures/Electrical Project stage: RAI ML11214A0272011-08-15015 August 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Programs Audit, Reactor Systems Project stage: RAI ML11214A0882011-08-15015 August 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Programs Audit, Plant Systems Project stage: RAI ML11238A0712011-08-18018 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application Project stage: Response to RAI ML1123000162011-08-18018 August 2011 License Renewal - Errata in AMP RAI Package Project stage: RAI NOC-AE-11002716, Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937)2011-08-18018 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937) Project stage: Response to RAI ML11238A0722011-08-23023 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application Project stage: Response to RAI NOC-AE-11002714, Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937)2011-08-23023 August 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application (TAC ME4936 and ME4937) Project stage: Response to RAI ML11230A0032011-09-0606 September 2011 Scoping and Screening Audit Report Regarding the South Texas Project, Units 1 and 2 Project stage: Other ML11266A0192011-09-15015 September 2011 Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI ML11266A0202011-09-15015 September 2011 Response to Requests for Additional Information for License Renewal Application Project stage: Response to RAI NOC-AE-11002731, Response to Requests for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937)2011-09-15015 September 2011 Response to Requests for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Response to RAI NOC-AE-11002730, Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937)2011-09-15015 September 2011 Response to Request for Additional Information for License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Response to RAI ML1124402012011-09-21021 September 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Review, Set 2 Project stage: RAI ML11250A0432011-09-22022 September 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Review, Set 1 Project stage: RAI ML11224A2652011-09-22022 September 2011 Aging Management Programs Audit Report Regarding the South Texas Project, Units 1 and 2, Station License Renewal Application Project stage: Other ML11258A1612011-09-22022 September 2011 Request for Additional Information for the Review of the South Texas Project, Units 1 and 2 License Renewal Application - Aging Management Review, Set 3 Project stage: RAI ML11272A1652011-10-0404 October 2011 Summary of Telephone Conference Call Held on September 28, 2011, Between the NRC and STP Nuclear Operating Company, Concerning Request for Additional Information Pertaining to the South Texas Project, LRA Project stage: RAI ML11291A1522011-10-10010 October 2011 Response to Requests for Additional Information for the License Renewal Application Project stage: Response to RAI NOC-AE-11002732, Response to Requests for Additional Information for the License Renewal Application2011-10-10010 October 2011 Response to Requests for Additional Information for the License Renewal Application Project stage: Response to RAI ML11291A1202011-10-10010 October 2011 10CFR50.59 Summary Report Project stage: Request ML11273A0172011-10-11011 October 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Aging Management Review, Set 5 Project stage: RAI ML11273A0082011-10-11011 October 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Aging Management Review, Set 4 Project stage: RAI ML11277A0472011-10-18018 October 2011 Requests for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Aging Management Program, Set 6 Project stage: RAI NOC-AE-11002737, Supplement to License Renewal Application (TAC Nos. ME4936 and ME4937)2011-10-18018 October 2011 Supplement to License Renewal Application (TAC Nos. ME4936 and ME4937) Project stage: Supplement ML11298A0822011-10-18018 October 2011 Supplement to License Renewal Application Project stage: Supplement ML11305A0762011-10-25025 October 2011 Response to Requests for Additional Information for License Renewal Application Project stage: Response to RAI NOC-AE-11002756, Contact Information Change, License Renewal Application (TAC ME4936 and ME4937)2011-10-26026 October 2011 Contact Information Change, License Renewal Application (TAC ME4936 and ME4937) Project stage: Other ML11305A0752011-10-26026 October 2011 Contact Information Change, License Renewal Application Project stage: Other ML11318A1772011-11-0303 November 2011 Drawing No. LR-STP-WL-7R309F90001 1, Rev. 1, Piping and Instrumentation Diagram Liquid Waste Processing System Project stage: Other ML11318A1722011-11-0303 November 2011 Drawing No. LR-STP-WL-5R309F05022 2, Rev. 1, Piping and Instrumentation Diagram Liquid Waste Processing System Project stage: Other 2011-06-16
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 June 15, 2012 Mr. D.W. Rencurrel, Senior Vice President Technical Support and Oversight STP Nuclear Operating Company P.O. Box 289 Wadsworth, TX 77483
SUBJECT:
REPORT REGARDING THE FOLLOW-UP AUDIT OF THE SELECTIVE LEACHING OF ALUMINUM BRONZE AGING MANAGEMENT PROGRAM FOR THE SOUTH TEXAS PROJECT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME4936 AND ME4937)
Dear Mr. Rencurrel:
By letter dated October 25, 2010, STP Nuclear Operating Company (STPNOC or the applicant) submitted an application for renewal of operating licenses NPF-76 and NPF-80 for South Texas Project (STP), Units 1 and 2. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants." On February 29, 2012, the staff completed a follow-up audit of the Selective Leaching of Aluminum Bronze aging management program. The audit report is enclosed.
If you have any questions, please contact me by telephone at 301-415-3873 or bye-mail at John. Daily@nrc.gov.
Sincerely,
- W~~Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-498 and 50-499
Enclosure:
As stated cc w/encl: Listserv
U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULA TION DIVISION OF LICENSE RENEWAL o
Docket Nos:
License Nos:
Licensee:
Facility:
Location:
Date:
Reviewers:
Approved By:
050-00498, 050-00499 NPF-76, NPF-80 South Texas Nuclear Operating Company South Texas Project, Units 1 and 2 P.O. Box 289 Wadsworth,TX 77483 February 29,2012 J. Daily, Sr. Project Manager, Audit Team Leader, Division of License Renewal (DLR)
R. Auluck, Branch Chief, DLR D. Morey, Branch Chief, DLR W. Holston, Sr. Mechanical Engineer, DLR D. Alley, Sr. Materials Engineer. DE D. Rudland, Sr. Materials Engineer, DE J. Tsao, Sr. Materials Engineer, DE J. Wise, Materials Engineer, DLR Rajender Auluck, Chief Aging Management of Plant Systems Branch Division of License Renewal Dennis Morey, Chief Projects Branch 1 Division of License Renewal ENCLOSURE
- 2 Introduction. By letter dated October 25,2010, STP Nuclear Operating Company (STPNOC or the applicant), submitted to the U.S. Nuclear Regulatory Commission (NRC or the staff) its application for renewal of Operating License Nos. NPF-76 and NPF-80 for South Texas Project (STP), Units 1 and 2, respectively. The applicant requested renewal of the operating licenses for an additional 20 years beyond the 40-year current license terms, which expire on August 20, 2027, for Unit 1 and December 15,2028, for Unit 2.
Purpose. The staff from the Division of License Renewal conducted a one-day follow-up regulatory audit on February 29, 2012, to gain a better understanding of the applicant's plant-specific aging management program (AMP) 82.1.37, "Selective leaching of Aluminum Bronze," and the associated bases, supporting documentation, and applicable aging management reviews (AMRs). The audit took place at a Nuclear Energy Institute office in Rockville, Maryland provided by the applicant.
Since the applicant's program is a plant-specific AMP, it is evaluated on an individual basis for all 10 program elements, along with any associated issues. While portions of this 10-element review had already been performed by the staff, this follow-up audit examined additional issues and documentation in order for the staff to complete its review.
Audit Activities. During its audit, the staff interviewed the applicant's staff and reviewed several areas of documentation provided by the applicant. The following topics were covered in detailed discussions with the applicant:
Current programmatic aspects of managing selective leaching of aluminum bronze, operating experience, repair and replacement activities, inservice inspection results, and the current status of components fabricated from aluminum bronze alloys.
- Methodology, inputs, assumptions, and conclusions for the flaw calculations that demonstrate structural integrity of welded joints and large castings affected by selective leaching, emphasizing the following:
o modeling of flaw dimensions and orientation, crack growth, and crack stability o how material properties were obtained o acceptance criteria in the applicant's calculations compared to ASME Code,Section III and Section XI requirements
- Metallurgical factors which appear to cause the observed selective leaching to be associated with weld heat affected zones, micrographs of heat affected zones, and review of selective leaching related to cracked areas of components.
- Common aging mechanisms impacting aluminum bronze throttle valve cracking and cavitation damage as described in STPNOC lER 499/2005-004 Fracture mechanics analyses performed to verify structural integrity when leaks are identified
- Operating experience for aluminum bronze piping, defects, and component leaks Results and pictures from sectioned material specimens removed from the plant
- Aging management strategy for buried pipe welds where there could be multiple leak sites that have not yet been identified
- 3
- Current and proposed future inspection activities, particularly the adequacy of the number and timing of destructive examinations in relation to confirming degree of selective leaching prior to and during the period of extended operation The table below lists the documents that were reviewed by the staff and were found relevant to the audit. These documents were provided by the applicant or were identified in the staff's search of the applicant's operating experience database.
Relevant Documents Reviewed Document Title Revision I Date
- 1.
STP-AMP-B2.1.37 Selective Leaching of Aluminum Bronze 1
2 APTECH 8303381 Structural Integrity Analysis of Essential Cooling Water Lines (STP)
Revision 1. Final Draft. July 1983
- 3. AES-C-1630-2 Calculation of Critical Bending Stress for Flawed Pipe Welds in the ECW System 7/7/1992
- 4. ST-HL-AE-2748 i Calculation (no title) 11/1/1988
- 5. AES-C-5862-1 Significance of Circumferential Crack in 30* Aluminum Bronze Pipe in ECW 7/25/2005
- 6. AES-C-1964-1 Calculation of Critical Bending Stress for Dealloyed Aluminum Bronze Castings in ECW System 1/2111994
- 7. AES-C-1964-2 ECW Water Hammer Force Summary 12/1311993 1 8. AES-C-1964-3 Significance of Water hammer Loads Relative to Seismic Loads in the ECW System 3/10/1995
- 9. AES-C-1964-4 Evaluation of6-inch Flange Test 6/3/1994
- 10. AES-C-1964-5 Evaluation of the Significance of Dealloying and Subsurface Cracks on Flaw Evaluation Method 12/2311994 11.AES-C-1964-6 Evaluation of Dealloying That Initiates at the Face of a Flange in the ECW Piping 2/20/1995 12.AES-C-1964-7 Leak Rate Analysis for a Circumferential Crack in 10-inch and 30-inch Underground ECW Piping 4/13/1995 13.RC 9890 Stress Summary for Large Bore ECW Piping (2-1/2" and Above) 5/20/1991 The staff identified several aspects of the AMP for which requests for additional information (RAls) will be required before the staff can determine whether the program will manage aging adequately. Anticipated RAls are associated with, but not necessarily limited to, the following issues:
-4
- 1. Phase composition of actual specimens.
- 2. Whether the 30 ksi ultimate tensile strength (UTS) is valid for the currently in-service dealloyed components.
- 3. Comparison and contrasting of crack morphology as opposed to dealloying morphology.
- 4. How use of the UTS (stated in item 2, above) instead of flow stress in the limit load analysis results in a conservative output from the analysis.
- 5. Why some of the calculations do not appear to use a design factor.
- 6. Determining if dealloying was involved in the six instances associated with cavitation damage downstream of butterfly valves.
- 7. How an external visual examination validates assumptions on internal crack dimensions.
- 8. Why destructive testing results are not available for dealloying degradation that has occurred from at least the mid nineties through the current time-period.
- 9. Allowable localized leak rate in above ground piping does not appear to be addressed in the updated final safety analysis report
- 10. The lack of any proposed volumetric examination screening for potential cracks at susceptible locations.
- 11. Terminology discrepancies in relief requests.
- 12. Submission of essential cooling water system dealloying and weld crack data tables on the docket.
- 13. Whether an insufficient number of destructive examinations was proposed in the response to RAI 82.1.37-1.
ML12165A239
- concurrence via email PM:DLR/RPB1 LA:DLR/RPB2 BC:DLR/RAPB
=======n PM:DLR/RPB1 JDaily IKing*
RAuluck JDaily 6/14/12 6/13/12 6/14/12 6/15/12
Letter to D.W. Rencurrel from John W. Daily dated June 15, 2012
SUBJECT:
REPORT REGARDING THE FOLLOW-UP AUDIT OF THE SELECTIVE LEACHING OF ALUMINUM BRONZE AGING MANAGEMENT PROGRAM FOR THE SOUTH TEXAS PROJECT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME4936 AND ME4937)
DISTRIBurlON:
E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDraApla Resource RidsOgcMailCenter Resource JDaily TTran RAuluck DMorey ICouret, OPA BSingal, DORL WWalker, RIV JDixon, RIV BTharakan, RIV WMaier, RIV VDricks, RIV NOKeefe, RIV AVegel, RIV SG raves, RIV