Category:Letter
MONTHYEARIR 05000302/20240012024-09-23023 September 2024 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3, NRC Inspection Report No. 05000302/2024001 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24226B2392024-08-27027 August 2024 Application for License Amendment Request to Add License Condition to Include License Termination Plan Requirements – Acknowledgement of Withdrawal ML24179A0702024-07-26026 July 2024 SHPO S106 Completion Crystal River Unit 3 ML24205A2202024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3_Miccosukee Tribe of Florida ML24205A2192024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3: Muscogee Nation ML24205A2182024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3: Seminole Nation of Oklahoma ML24179A0912024-07-24024 July 2024 Tribal S106 Completion Crystal River Unit 3: Seminole Tribe of Florida ML24190A1912024-07-0808 July 2024 Fws Concurrence for Crystal River Unit 3 ML24172A2552024-06-20020 June 2024 Fws to NRC Species List: Florida Ecological Services Field Office 06/20/2024 ML24170A9242024-06-18018 June 2024 024-0023697 Crystal River License Termination Plan Unit 3 ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24114A2262024-04-24024 April 2024 Amended Special Package Authorization for the Cr3 Middle Package (Crystal River 3 Middle Package - Docket No. 71-9393) IR 05000302/20230022024-04-17017 April 2024 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2023002 ML24054A0812024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Osceola, Marcellus ML24054A0612024-04-0202 April 2024 Request to Initiate Section 106 Consultation Regarding the License Termination Plan for Crystal River Unit 3 in Citrus County, Florida ML24079A2492024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Johnson, Lewis Johnson ML24079A2482024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Hill, David Hill ML24079A2472024-04-0202 April 2024 Tribal S106 Initiation Crystal River Unit 3-Cypress, Talbert ML24054A0582024-04-0202 April 2024 Achp S106 Initiation Crystal River Unit 3 - Letter 1 ML24089A0362024-03-29029 March 2024 Response to Audit Plan in Support of Accelerated Decommissioning Partners and Request to Add License Condition to Include License Termination Plan Requirements. W/Enclosures 1 to 5 ML24073A1922024-03-11011 March 2024 Fws to NRC, List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML24054A6452024-02-29029 February 2024 Letter - Reply to Request for RAI Extension Related to the Crystal River License Termination Plan ML24030A7482024-02-12012 February 2024 Audit Report Cover Letter and Report - Crystal River Unit 3 Nuclear Generating Plant LTP ML23342A0942024-01-0909 January 2024 – Independent Spent Fuel Storage Installation Security Inspection Plan ML23354A0632023-12-22022 December 2023 Cover Letter - Crystal River License Termination Plan Request for Additional Information ML23345A1882023-12-0606 December 2023 Fws to NRC Crystal River Species List of Threatened and Endangered Species That May Occur in Your Proposed Project Location or May Be Affected by Your Proposed Project ML23313A1322023-11-15015 November 2023 Request for Additional Information for the Environmental Assessment of the License Termination Plan for Crystal River Unit 3 Nuclear Generating Plant ML23310A0712023-11-0707 November 2023 Audit Plan Cover Letter - Crystal River Unit 3 Nuclear Generating Plant LTP ML23187A1112023-07-25025 July 2023 Acceptance of Requested Licensing Action License Request to Add License Condition to Include License Termination Plan Requirements ML23107A2722023-06-13013 June 2023 Letter Transmitting NRC Survey Results for East Settling Pond ML23160A2962023-06-0909 June 2023 Response to Crystal River, Unit 3 – Supplemental Information Needed for Acceptance on the Application for a License Amendment Regarding Approval of the License Termination Plan ML23107A2732023-06-0707 June 2023 Orise Independent Survey Report Dcn 5366-SR-01-0 ML23103A1902023-04-19019 April 2023 Request for Supplemental Information Cover Letter IR 05000302/20220032023-03-22022 March 2023 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River, Unit 3 - NRC Inspection Report No. 05000302/2022003 ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML22265A0192022-09-26026 September 2022 Nuclear Generating Plant - U.S. Nuclear Regulatory Commissions Analysis of ADP CR3, LLCs Decommissioning Funding Status Report (License No. DPR-72, Docket Nos. 50-302 and 72-1035) IR 05000302/20220022022-08-0909 August 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report 05000302/2022002 IR 05000302/20220012022-05-0303 May 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report 05000302/2022001 ML22116A1752022-04-27027 April 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3- Independent Spent Fuel Storage Installation Security Inspection Report 07201035/2022401 ML22105A3992022-04-18018 April 2022 Nuclear Generating Plant - Change in NRC Project Manager ML22011A1362022-01-31031 January 2022 Independent Spent Fuel Storage Installation Security Inspection Plan ML22024A2142022-01-24024 January 2022 Nuclear Generating Plant - NMFS NRC Letter - Crystal River Energy Complex Biological Opinion Status (License No. DPR-72, Docket Nos. 50-302 and 72-1035) IR 05000302/20210042022-01-24024 January 2022 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report No. 05000302/2021004 ML21351A0052021-12-20020 December 2021 NRC Analysis of ADP CR3, LLC Decommissioning Funding Status Report for the Crystal River Unit 3 Nuclear Generating Plant (License No. DPR-72, Docket Nos. 50-302 and 72-1035) ML21322A2702021-11-24024 November 2021 Nuclear Generating Plant - Issuance of Amendment No. 260 Approving the Independent Spent Fuel Storage Installation Only Security Plan, Rev 3 IR 05000302/20210032021-11-0909 November 2021 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report Nos. 05000302/2021003 and 07201035/2021001 ML21288A4292021-10-18018 October 2021 Letter - Crystal River Unit 3 Nuclear Generating Plant - Correction to Safety Evaluation Related to the Issuance of Amendment No. 259 Approving the Independent Spent Fuel Storage Installation Only Emergency Plan ML21238A0952021-10-13013 October 2021 Issuance of Amendment No. 259 Approving the ISFSI-Only Emergency Plan, Revision Draft a IR 05000302/20210012021-08-12012 August 2021 Accelerated Decommissioning Partners (ADP) CR3, LLC, Crystal River Unit 3 - NRC Inspection Report Nos. 05000302/2021001 and 05000302/2021002 2024-09-23
[Table view] Category:License-Application for Facility Operating License (Amend/Renewal) DKT 50
MONTHYEAR3F0623-02, Maintenance Support Building2023-06-0909 June 2023 Maintenance Support Building ML23160A2982023-06-0909 June 2023 Site Characterization Surveys ML23160A2972023-06-0909 June 2023 CR3 Site Characterization Survey Report (CHAR-01) Impacted Open Land Survey Areas ML23160A2962023-06-0909 June 2023 Response to Crystal River, Unit 3 – Supplemental Information Needed for Acceptance on the Application for a License Amendment Regarding Approval of the License Termination Plan 3F1222-01, Nuclear Power Station - License Amendment Request 262 Addition of License Condition 2.C.21, License Termination Plan2022-12-12012 December 2022 Nuclear Power Station - License Amendment Request 262 Addition of License Condition 2.C.21, License Termination Plan 3F0122-01, License Amendment Request to Remove from the Facility Operating License, Appendix B, Environmental Protection Plan (Non-Radiological) Technical Specifications2022-01-26026 January 2022 License Amendment Request to Remove from the Facility Operating License, Appendix B, Environmental Protection Plan (Non-Radiological) Technical Specifications 3F0321-02, License Amendment Request, Rev. 0, ISFSI Security Plan, Rev. a2021-03-17017 March 2021 License Amendment Request, Rev. 0, ISFSI Security Plan, Rev. a 3F1120-02, And Crystal River Nuclear Plant - Application for Order Approving Indirect Transfers of Control of Licenses in Connection with Internal Corporate Reorganization2020-11-19019 November 2020 And Crystal River Nuclear Plant - Application for Order Approving Indirect Transfers of Control of Licenses in Connection with Internal Corporate Reorganization 3F0619-01, Application for Order Consenting to Direct Transfer of Control of Licenses and Approving Conforming License Amendment2019-06-14014 June 2019 Application for Order Consenting to Direct Transfer of Control of Licenses and Approving Conforming License Amendment ML19130A1952019-05-0808 May 2019 Letter - FEMA Review of Proposed Changes to DBNPS Emergency Plan for Permanently Defueled Condition 3F0119-02, License Amendment Request 326, Revision 0, ISFSI Only Emergency Plan, Revision 12019-01-16016 January 2019 License Amendment Request #326, Revision 0, ISFSI Only Emergency Plan, Revision 1 3F0717-01, Submittal of Crystal River Unit 3 - License Amendment Request 321, Revision 1, ISFSI Only Physical Security Plan2017-07-0505 July 2017 Submittal of Crystal River Unit 3 - License Amendment Request #321, Revision 1, ISFSI Only Physical Security Plan 3F1216-01, License Amendment Request 324, Revision 0, Cyber Security Plan License Condition Removal2016-12-0909 December 2016 License Amendment Request #324, Revision 0, Cyber Security Plan License Condition Removal 3F0816-01, License Amendment Request 323, Revision 0, Permanently Defueled Technical Specifications for the Independent Spent Fuel Storage Installation to Reflect Permanent Removal of Spent Fuel from the Spent Fuel Pools2016-08-31031 August 2016 License Amendment Request #323, Revision 0, Permanently Defueled Technical Specifications for the Independent Spent Fuel Storage Installation to Reflect Permanent Removal of Spent Fuel from the Spent Fuel Pools 3F0316-01, License Amendment Request No. 320, Revision 0, Cyber Security Plan Implementation Schedule Milestone 82016-03-31031 March 2016 License Amendment Request No. 320, Revision 0, Cyber Security Plan Implementation Schedule Milestone 8 3F0915-01, Supplement to Application for Order Approving Transfer of License and for Conforming License Amendment Pursuant to 10 CFR 50.80 and 10 CFR 50.902015-09-22022 September 2015 Supplement to Application for Order Approving Transfer of License and for Conforming License Amendment Pursuant to 10 CFR 50.80 and 10 CFR 50.90 3F0815-01, License Amendment Request No. 318, Revision 0, Permanently Defueled Emergency Plan, Revision 2, and Permanently Defueled Emergency Action Level Bases Manual, Revision 1, for the Independent Spent Fuel Storage Installation2015-08-27027 August 2015 License Amendment Request No. 318, Revision 0, Permanently Defueled Emergency Plan, Revision 2, and Permanently Defueled Emergency Action Level Bases Manual, Revision 1, for the Independent Spent Fuel Storage Installation 3F0715-03, Application for Order Approving Transfer of License and for Conforming License Amendment Pursuant to 10 CFR 50.80 and 10 CFR 50.902015-07-28028 July 2015 Application for Order Approving Transfer of License and for Conforming License Amendment Pursuant to 10 CFR 50.80 and 10 CFR 50.90 3F1114-01, Application for Order Approving Transfer of License and for Conforming License Amendment Pursuant to 10 CFR 50.80 and 10 CFR 50.902014-11-0707 November 2014 Application for Order Approving Transfer of License and for Conforming License Amendment Pursuant to 10 CFR 50.80 and 10 CFR 50.90 RA-13-1001, License Amendment Request - Cyber Security Plan Implementation Schedule Milestone 82013-12-19019 December 2013 License Amendment Request - Cyber Security Plan Implementation Schedule Milestone 8 3F0913-04, License Amendment Request 315, Revision 0, Permanently Defueled Emergency Plan and Emergency Action Level Scheme, and Request for Exemption to Certain Radiological Emergency Response Plan Requirements Defined by 10 CFR 502013-09-26026 September 2013 License Amendment Request #315, Revision 0, Permanently Defueled Emergency Plan and Emergency Action Level Scheme, and Request for Exemption to Certain Radiological Emergency Response Plan Requirements Defined by 10 CFR 50 3F0913-02, License Amendment Request 313, Revision 1, Revision to Improved Technical Specifications Administrative Controls for Permanently Defueled Conditions and Response to Requests for Additional Information2013-09-0404 September 2013 License Amendment Request #313, Revision 1, Revision to Improved Technical Specifications Administrative Controls for Permanently Defueled Conditions and Response to Requests for Additional Information 3F0413-01, License Amendment Request 313, Revision 0, Revision to Improved Technical Specifications Administrative Controls for Permanently Defueled Conditions2013-04-25025 April 2013 License Amendment Request #313, Revision 0, Revision to Improved Technical Specifications Administrative Controls for Permanently Defueled Conditions 3F0313-03, Renewal of the Crystal River Units 1, 2 and 3 Industrial Wastewater Permit FL00001592013-03-0606 March 2013 Renewal of the Crystal River Units 1, 2 and 3 Industrial Wastewater Permit FL0000159 RA-12-031, Carolina Power & Light Company and Florida Power Corporation'S License Amendment Request - Cyber Security Plan Implementation Schedule Milestones2012-09-12012 September 2012 Carolina Power & Light Company and Florida Power Corporation'S License Amendment Request - Cyber Security Plan Implementation Schedule Milestones 3F0112-10, License Amendment Request 311, Revision 1, Emergency Feedwater Pump Fuel Oil Volume2012-01-19019 January 2012 License Amendment Request #311, Revision 1, Emergency Feedwater Pump Fuel Oil Volume 3F0611-02, Attachments 1, 2 & 3, 4 & 6 Crystal River Unit 3, License Amendment Request 309, Revision 0 Attachment 1, Description of Proposed Change, Background, Justification for the Request, Determination of No Significant Hazards Considerations2011-06-15015 June 2011 Attachments 1, 2 & 3, 4 & 6 Crystal River Unit 3, License Amendment Request #309, Revision 0 Attachment 1, Description of Proposed Change, Background, Justification for the Request, Determination of No Significant Hazards Considerations RA-11-010, Progress Energy Carolinas, Inc., & Progress Energy Florida, Inc., Submittal of Application for Approval of Indirect Transfers of Control of License Pursuant to 10 CFR 50.80 and 10 CFR ,72.502011-03-30030 March 2011 Progress Energy Carolinas, Inc., & Progress Energy Florida, Inc., Submittal of Application for Approval of Indirect Transfers of Control of License Pursuant to 10 CFR 50.80 and 10 CFR ,72.50 3F0311-04, License Amendment Request 313, Revision 0 Revise Shutdown Margin Definition for Stuck Rod Exception2011-03-24024 March 2011 License Amendment Request #313, Revision 0 Revise Shutdown Margin Definition for Stuck Rod Exception 3F0211-01, License Amendment Request 311, Revision 0, Emergency Feedwater Pump Fuel Oil Volume2011-02-25025 February 2011 License Amendment Request #311, Revision 0, Emergency Feedwater Pump Fuel Oil Volume 3F1210-05, License Amendment Request 310, Revision 0, Departure from a Method of Evaluation for Auxiliary Building Overhead Crane and Revisions to Associated Commitments2010-12-20020 December 2010 License Amendment Request #310, Revision 0, Departure from a Method of Evaluation for Auxiliary Building Overhead Crane and Revisions to Associated Commitments RA-10-011, Request for Approval of the Carolina Power & Light Company and Florida Power Corporation Cyber Security Plan2010-07-0808 July 2010 Request for Approval of the Carolina Power & Light Company and Florida Power Corporation Cyber Security Plan 3F0209-05, License Amendment Request 307, Revision 0, Methodology for Rod Ejection Accident Analysis Under Extended Power Uprate Conditions2009-02-26026 February 2009 License Amendment Request #307, Revision 0, Methodology for Rod Ejection Accident Analysis Under Extended Power Uprate Conditions 3F0209-06, License Amendment Request 310, Revision 0: Application to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-490, Rev. 0, Deletion of E Bar Definition and Revision to RCS Specific Activity Technical Specification2009-02-26026 February 2009 License Amendment Request #310, Revision 0: Application to Adopt Technical Specifications Task Force (TSTF) Traveler TSTF-490, Rev. 0, Deletion of E Bar Definition and Revision to RCS Specific Activity Technical Specification 3F1208-06, License Amendment Request 300, Revision 0 Addition of TSTF 479, Revision 0 and TSTF 497, Revision 0 to the Inservice Testing (IST) Program2008-12-17017 December 2008 License Amendment Request #300, Revision 0 Addition of TSTF 479, Revision 0 and TSTF 497, Revision 0 to the Inservice Testing (IST) Program ML0900502532008-12-16016 December 2008 Systems Drawings Supporting License Renewal ML0900800552008-12-16016 December 2008 License Renewal Application. Cover Page to Section 3.2 ML0900800562008-12-16016 December 2008 License Renewal Application. Section 3.3 ML0900807292008-12-16016 December 2008 License Renewal Application. Section 3.5 to End ML0900807312008-11-30030 November 2008 License Renewal Application, Consisting of Applicant'S Environmental Report 3F1108-01, License Amendment Request 304, Revision 0, Emergency Diesel Generator Voltage and Frequency Limits Revision2008-11-0606 November 2008 License Amendment Request #304, Revision 0, Emergency Diesel Generator Voltage and Frequency Limits Revision ML0828301372008-10-0606 October 2008 License Amendment Request to Eliminate Work Hour Controls to Support Compliance with Revised 10 CFR 26 3F0808-01, License Amendment Request 301, Revision 0, Application to Modify Improved Technical Specifications for Replacement Steam Generators2008-08-28028 August 2008 License Amendment Request #301, Revision 0, Application to Modify Improved Technical Specifications for Replacement Steam Generators 3F0708-09, License Amendment Request 299, Revision 1, Supplement 1, Application to Revise Technical Specifications Control Room Envelope Habitability in Accordance with TSTF 448, Revision 3, Using the Consolidated Line Item..2008-07-29029 July 2008 License Amendment Request #299, Revision 1, Supplement 1, Application to Revise Technical Specifications Control Room Envelope Habitability in Accordance with TSTF 448, Revision 3, Using the Consolidated Line Item.. 3F0608-08, License Amendment Request 299, Revision 1: Application to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using Consolidated Line Item Improvement Process..2008-06-19019 June 2008 License Amendment Request #299, Revision 1: Application to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using Consolidated Line Item Improvement Process.. 3F0108-14, License Amendment Request 298, Revision 0: Application to Modify Improved Technical Specifications for Replacement Steam Generators2008-01-22022 January 2008 License Amendment Request #298, Revision 0: Application to Modify Improved Technical Specifications for Replacement Steam Generators 3F0108-03, License Amendment Request 302, Revision 0, Surveillance Requirement (SR) 3.7.5.2: Emergency Feedwater System2008-01-17017 January 2008 License Amendment Request #302, Revision 0, Surveillance Requirement (SR) 3.7.5.2: Emergency Feedwater System 3F1007-01, License Amendment Request No. 275, Revision 0, Application for Technical Specification Change TSTF-374, Revision to ITS 5.6.2.14 and Associated Bases for Diesel Fuel Oil Using the Consolidated Line Item Improvement Process2007-10-25025 October 2007 License Amendment Request No. 275, Revision 0, Application for Technical Specification Change TSTF-374, Revision to ITS 5.6.2.14 and Associated Bases for Diesel Fuel Oil Using the Consolidated Line Item Improvement Process 3F0807-05, License Amendment Request (LAR) 296, Revision 1, Supplement 1: Measurement Uncertainty Recapture, Submittal of the Cameron Bounding Uncertainty Analysis Report2007-08-30030 August 2007 License Amendment Request (LAR) #296, Revision 1, Supplement 1: Measurement Uncertainty Recapture, Submittal of the Cameron Bounding Uncertainty Analysis Report 3F0807-03, License Amendment Request 294, Revision 0, Elimination of Spent Fuel Pool Missile Shields, Supplement 12007-08-23023 August 2007 License Amendment Request #294, Revision 0, Elimination of Spent Fuel Pool Missile Shields, Supplement #1 2023-06-09
[Table view] |
Text
Progress Energy Crystal River Nuclear Plant Docket No. 50-302 Operating License No. DPR-72 Ref: 10 CFR 54 December 16, 2008 3F1208-02 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
Subject:
Crystal River Unit 3 - Systems Drawings Supporting License Renewal
Reference:
Crystal River Unit 3 to NRC Letter dated December 16, 2008, "Crystal River Unit 3 - Application for Renewal of Operating License"
Dear Sir:
By letter dated December 16, 2008, Florida Power Corporation (FPC), doing business as Progress Energy Florida, Inc., submitted an application to the Nuclear Regulatory Commission (NRC) for the renewal of the operating license for the Crystal River Unit 3 Nuclear Generating Plant (CR-3). In support of that application, drawings were prepared for the majority of mechanical systems to supplement license renewal scoping calculations and provide a visual representation of portions of mechanical systems within the scope of license renewal. The drawings were developed using existing system flow diagrams, where available, and they have been highlighted to show the system boundaries associated with fulfilling one or more system intended functions as discussed in 10 CFR 54.4(b). These drawings are not part of the official application for license renewal; however, FPC is making them available to the NRC staff as additional information to support a more efficient review.
The enclosures to this letter are: (1) an index of drawings supporting CR-3 license renewal and (2) a single compact disc (CD) that contains the drawing files as indicated on the following table.
In addition, three paper copy sets of the referenced drawings are being provided to NRR (i.e., to Mr. Rob Kuntz, the License Renewal Project Manager for CR-3), and one paper copy set is being provided to the NRC Region II Regional Administrator.
List of Electronic Files File Name Approximate File Size Access 001 LR Scoping Drawing Index.pdf 183 KB1 Publically Available Various - 130 System Drawings in pdf format Average File: 1,117 KB Publically Available No new regulatory commitments are made in this submittal.
Progress Energy Florida, Inc.
Crystal River Nuclear Plant 15760 W. Powerline Street 140O3 Crystal River, FL 34428
U. S. Nuclear Regulatory Commission Page 2 of 2 3F1208-02 I
Please refer any questions regarding this submittal to Mr. Mike Heath, Supervisor - License Renewal, at (910) 457-3487, e-mail at mike.heath@pgnmail.com.
Sincerely, Dale E. Young Vice President Crystal River Nuclear Plant DEY/dwh
Enclosures:
- 1. License Renewal Scoping Drawing Index
- 2. CR-3 License Renewal Scoping Drawings CD-ROM xc:
NRC Senior Resident Inspector NRC License Renewal Project Manager Regional Administrator, Region II NRC CR-3 Project Manager
PROGRESS ENERGY FLORIDA, INC.
CRYSTAL RIVER UNIT 3 DOCKET NUMBER 50 - 302 / LICENSE NUMBER DPR - 72 ENCLOSURE I LICENSE RENEWAL SCOPING DRAWING INDEX
U. S. Nuclear Regulatory Commission Enclosure 1 3F1208-02 Page 1 of 4 LICENSE RENEWAL SCOPING DRAWING INDEX Drawing Legend and Scoping Notes Scoping Drawing Symbols [ 302-001-LR, Sheet 1 Scoping Drawing Instrumentation Symbols [302-002-LR, Sheet 1 Reactor Vessel, Internals, and Reactor Coolant System Reactor Coolant System 302-651-LR, Sheet 1 302-651-LR, Sheet 2 Control Rod Drive Control System None Incore Monitoring System None Engineered Safety Features Reactor Building Spray System 302-711-LR, Sheet 1 302-712-LR, Sheet 1 Core Flood System 302-702-LR, Sheet 1 Decay Heat Removal System 302-641-LR, Sheet 1 302-641-LR, Sheet 2 Engineered Safeguards Actuation System None Reactor Building Isolation System None Auxiliary Systems Air Handling Ventilation and Cooling System 302-751-LR, Sheet 1 302-753-LR, Sheet 1 302-753-LR, Sheet 2 302-754-LR, Sheet 1 302-754-LR, Sheet 2 302-769-LR, Sheet 1 302-778-LR, Sheet 1 Reactor Building Recirculation System 302-751-LR, Sheet 1 Reactor Building Miscellaneous Ventilation System 302-751-LR, Sheet 1 Reactor Building Purge System 302-751-LR, Sheet 1 Auxiliary Building Supply System 302-751-LR, Sheet 1 Fuel Handling Area Supply System 302-751-LR, Sheet 1 Decay Heat Closed Cycle Pump Cooling System 302-751-LR, Sheet 1 Spent Fuel Coolant Pump Cooling System 302-751-LR, Sheet 1 Spent Fuel Pit Supply System 302-751-LR, Sheet 1 Auxiliary Building Exhaust System 302-752-LR, Sheet 1 302-766-LR, Sheet 1 Control Complex Ventilation System 302-753-LR, Sheet 1 302-753-LR, Sheet 2 302-753-LR, Sheet 3 302-753-LR, Sheet 4 302-766-LR, Sheet 1 Emergency Diesel Generator Air Handling System 302-754-LR, Sheet 1 Miscellaneous Area HVAC System 302-752-LR, Sheet 1 302-754-LR, Sheet 1 302-754-LR, Sheet 2 Turbine Building Ventilation System 302-754-LR, Sheet 1 302-754-LR, Sheet 2 Penetration Cooling System 302-755-LR, Sheet 1 Emergency Feedwater Initiation and Control Room HVAC 302-765-LR, Sheet 1 System
U. S. Nuclear Regulatory Commission Enclosure 1 3F1208-02 Page 2 of 4 Auxiliary Systems (continued)
Appendix R Control Complex Dedicated Cooling Supply 302-769-LR, Sheet 1 System Emergency Feedwater Pump Building Ventilation System 302-754-LR, Sheet 2 Chemical Addition System 302-671-LR, Sheet 1 Liquid Sampling System 302-672-LR, Sheet 1 302-672-LR, Sheet 2 PostAccident Liquid Sampling System 302-700-1-R, Sheet 1 302-700-LR, Sheet 2 Control Complex Chilled Water System 302-756-LR, Sheet 1 Appendix R Chilled Water System 302-765-LR, Sheet 1 302-769-LR, Sheet 1 Industrial Cooling System 302-762-LR, Sheet 1 302-762-LR, Sheet 3 Circulating Water System 302-201-LR, Sheet 1 EFP-3 Diesel Air Starting System 302-778-LR, Sheet 1 Decay Heat Closed Cycle Cooling System 302-631-LR, Sheet 1 302-631-LR, Sheet 2 Fuel Oil System 302-776-LR, Sheet 1 302-281-LR, Sheet 1 Jacket Coolant System 302-283-LR, Sheet 1 302-283-LR, Sheet 2 302-284-LR, Sheet 1 302-284-LR, Sheet 2 302-777-LR, Sheet 1 Diesel Generator Lube Oil System 302-285-LR, Sheet 1 302-285-LR, Sheet 2 302-775-LR, Sheet 1 Domestic Water System 302-211-LR, Sheet 1 Demineralized Water System 302-182-LR, Sheet 1 302-182-LR, Sheet 2 302-162-LR, Sheet 1 Emergency Diesel Generator System 302-281-LR, Sheet 1 302-282-LR, Sheet 1 302-283-LR, Sheet 1 302-283-LR, Sheet 2 302-284-LR, Sheet 1 302-284-LR, Sheet 2 Floor Drains System 302-683-LR, Sheet 1 302-683-LR, Sheet 2 Fuel Handling System None Fire Protection System 302-231-LR, Sheet 1 302-231-LR, Sheet 2 302-231-LR, Sheet 3 302-231-LR, Sheet 4 302-231-LR, Sheet 7 302-232-LR, Sheet 1 Hydrogen Supply System 302-673-LR, Sheet 3 Instrument Air System 302-271-LR, Sheet 1 302-271-LR, Sheet 2 302-271-LR, Sheet 4
_302-271-LR, Sheet 5
U. S. Nuclear Regulatory Commission Enclosure 1 3F1208-02 Page 3 of 4 Auxiliary Systems (continued)
Reactor Coolant Pump Lube Oil Collection System 302-292-LR, Sheet 1 Leak Rate Test System 302-722-LR, Sheet 1 302-723-LR, Sheet 1 Miscellaneous Drains System 302-114-LR, Sheet 2 Make Up & Purification System 302-661-LR, Sheet 1 302-661-LR, Sheet 2 302-661-LR, Sheet 3 302-661-LR, Sheet 4 Miscellaneous Mechanical & Structures System 302-752-LR, Sheet 1 Nitrogen Supply System 302-673-LR, Sheet 1 302-673-LR, Sheet 2 Penetration Cooling Auxiliary System 302-755-LR, Sheet 1 Reactor Building Airlock System 302-772-LR, Sheet 1 Roof Drains System None Radiation Monitoring System 302-695-LR, Sheet 1 302-693-LR, Sheet 1 Nuclear Service and Decay Heat Sea Water System 302-611-LR, Sheet 1 302-611-LR, Sheet 2 Station Air System 302-271-LR, Sheet 1 302-271-LR, Sheet 2 302-271-LR, Sheet 7 302-271-LR, Sheet 9 302-772-LR, Sheet 1 Secondary Services Closed Cycle Cooling Water System 302-221-LR, Sheet 1 302-221-LR, Sheet 2 302-221-LR, Sheet 3 Station Drains System 302-113-LR, Sheet 2 302-115-LR, Sheet 1 302-163-LR, Sheet 1 302-683-LR, Sheet 2 302-281-LR, Sheet 1 302-611 -LR, Sheet 2 Spent Fuel Cooling System 302-621-LR, Sheet 1 302-621-LR, Sheet 2 Nuclear Services Closed Cycle Cooling System 302-601-LR, Sheet 1 302-601-LR, Sheet 2 302-601-LR, Sheet 3 302-601-LR, Sheet 4 Waste Disposal System 302-681-LR, Sheet 1 302-681-LR, Sheet 2 302-681-LR, Sheet 3 302-681-LR, Sheet 4 302-681-LR, Sheet 5 Radioactive Gas Waste Disposal System 302-691-LR, Sheet 1 302-691-LR, Sheet 2 Radioactive Liquid Waste Disposal System 302-681-LR, Sheet 1 302-681-LR, Sheet 2 302-681-LR, Sheet 3 302-681-LR, Sheet 4 302-681-LR, Sheet 5 302-682-LR, Sheet 1 Reactor Coolant and Miscellaneous Waste Evaporator None System
U. S. Nuclear Regulatory Commission Enclosure 1 3F1208-02 Page 4 of 4 Auxiliary Systems (continued)
Waste Gas Sampling System 302-692-LR, Sheet 1 Waste Sampling System 302-693-LR, Sheet 1 Post Accident Containment Atmospheric Sampling 302-693-LR, Sheet 1 302-694-LR, Sheet 1 302-695-LR, Sheet 1 Steam and Power Conversion Systems Condenser Air Removal System 302-131-LR, Sheet 1 Auxiliary Steam System 302-051-LR, Sheet 1 302-114-LR, Sheet 2 302-114-LR, Sheet 3 Condensate Chemical Treatment System None Condensate System 302-101-LR, Sheet 1 302-101-LR, Sheet 2 OTSG Chemical Cleaning System 302-011-LR, Sheet 2 302-192-LR, Sheet 1 CD & FW Chemical Cleaning System 302-195-LR, Sheet 1 Condensate Demineralizer System 302-161-LR, Sheet 1 302-161-LR, Sheet 2 302-163-LR, Sheet 2 Emergency Feedwater System 302-082-LR, Sheet 1 302-082-LR, Sheet 2 Electro-Hydraulic Control System 302-773-LR, Sheet 1 Main Feedwater System 302-081-LR, Sheet 1 302-081-LR, Sheet 2 302-081-LR, Sheet 4 Gland Steam System 302-141-LR, Sheet 1 302-141-LR, Sheet 2 302-141-LR, Sheet 3 Gland Seal Water System 302-142-LR, Sheet 1 302-142-LR, Sheet 2 Heater Drains System None Heater Vents System None Main Feedwater Turbine Lube Oil System 302-770-LR, Sheet 1 302-770-LR, Sheet 2 Main Steam System 302-011-LR, Sheet 1 302-011-LR, Sheet 2 302-011-LR, Sheet 3 302-111 -LR, Sheet 3 302-114-LR, Sheet 1 302-114-LR, Sheet 2 302-114-LR, Sheet 3 302-051-LR, Sheet 1 Relief Valve Vent System 302-011-LR, Sheet 1 Secondary Plant System 302-081-LR, Sheet 1 Cycle Startup System 302-031-LR, Sheet 1 Turbine Generator 302-773-LR, Sheet 1
__302-773-LR, Sheet 2
PROGRESS ENERGY FLORIDA, INC.
CRYSTAL RIVER UNIT 3 DOCKET NUMBER 50 - 302 / LICENSE NUMBER DPR - 72 ENCLOSURE 2 CR-3 LICENSE RENEWAL SCOPING DRAWINGS CD-ROM