MONTHYEARL-PI-08-047, License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+ Fuel2008-06-26026 June 2008 License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+ Fuel Project stage: Request ML0822101322008-07-22022 July 2008 Email - Prairie Island Acceptance Review Questions for LAR to Allow Use of West. 14X14 Vantage+ Fuel (TACs MD9142/MD9143) Project stage: Acceptance Review ML0820605722008-07-28028 July 2008 Request for Supplemental Information, Acceptance Review of License Amendment Request Project stage: Acceptance Review L-PI-08-071, Supplement to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel2008-08-26026 August 2008 Supplement to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel Project stage: Supplement ML0822614492008-08-28028 August 2008 Acceptance of Requested Licensing Action Technical Specification Changes to Allow Use of Westinghouse 0.422-inch OD 14X14 Vantage+ Fuel Project stage: Acceptance Review ML0828106452008-10-17017 October 2008 Request for Additional Information Related to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage+Fuel (Tac No. MD9142, MD9143) Project stage: RAI L-PI-08-096, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse. 0.422- Inch OD 14x14 Vantage + Fuel2008-11-14014 November 2008 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse. 0.422- Inch OD 14x14 Vantage + Fuel Project stage: Response to RAI ML0833002102008-12-15015 December 2008 Request for Additional Information Related to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage + Fuel (TAC Nos. MD9142/9143) Project stage: RAI ML0835200472008-12-30030 December 2008 Request Withholding Information from Public Disclosure for Prairie Island Nuclear Generating Plant, Units 1 and 2 (Tac Nos. MD9142 and MD9143) Project stage: Other ML0835800982009-01-12012 January 2009 Request for Additional Information Related to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage + Fuel (TAC Nos. MD9142/9143) Project stage: RAI L-PI-09-011, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel2009-01-30030 January 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel Project stage: Response to RAI L-PI-09-022, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel2009-02-0909 February 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel Project stage: Response to RAI ML0901403342009-02-11011 February 2009 RAI for TS Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+Fuel Project stage: RAI L-PI-09-025, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage+ Fuel2009-02-20020 February 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage+ Fuel Project stage: Response to RAI L-PI-09-034, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage + Fuel2009-03-12012 March 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage + Fuel Project stage: Response to RAI ML0907210882009-03-12012 March 2009 Enclosure 1, Non-Proprietary Responses to Requests for Additional Information License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 422V+ Fuel Project stage: Response to RAI ML0907102152009-03-25025 March 2009 Request for Withholding Information from Public Disclosure for Prairie Island Nuclear Generating Plant, Units 1 and 2 Project stage: Withholding Request Acceptance L-PI-09-066, 422V+Fuel Transition Project RAI Response-EMCB RAI-1(a)2009-04-27027 April 2009 422V+Fuel Transition Project RAI Response-EMCB RAI-1(a) Project stage: Other L-PI-09-065, Supplemental Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+Fuel2009-05-0404 May 2009 Supplemental Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+Fuel Project stage: Supplement ML0913103842009-05-0404 May 2009 Clarification of Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage+ Fuel Project stage: Response to RAI ML0914905612009-06-0808 June 2009 Request for Withholding Information from Public Disclosure for Prairie Island Nuclear Generating Plant, Units 1 and 2 Project stage: Withholding Request Acceptance ML0917402012009-06-25025 June 2009 Public Letter Draft Safety Evaluation for License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+ Fuel Project stage: Draft Approval ML0914608092009-07-0101 July 2009 Issuance of Amendments Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage + Fuel Project stage: Approval ML0922403322009-08-31031 August 2009 Correction to Safety Evaluation Supporting Amendment Nos. 192 and 181 Technical Specification Changes to Allow Use of Westinghouse 0.422-Inch OD 14 X 14 Vantage+ Fuel (TAC Nos. MD9142/MD9143) Project stage: Approval ML0925703672009-09-15015 September 2009 Correction to Technical Specifications (TAC Nos. MD9142 and MD9143) Project stage: Other 2009-02-11
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000282/20230042024-02-0101 February 2024 Integrated Inspection Report 05000282/2023004 and 05000306/2023004 ML23356A1232024-01-29029 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting) ML24024A0722024-01-24024 January 2024 Independent Spent Fuel Storage Installation, Onticello, Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML24017A0182024-01-19019 January 2024 Confirmation of Initial License Examination ML23356A0032024-01-17017 January 2024 Issuance of Amendments Revise Technical Specification 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR) L-PI-23-034, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System,2024-01-0202 January 2024 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.7.8, Cooling Water (Cl) System, L-PI-23-035, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report2023-12-20020 December 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications Section 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report IR 07200010/20234012023-12-20020 December 2023 Independent Spent Fuel Storage Installation Security Inspection Report 07200010/2023401 ML23349A0572023-12-15015 December 2023 and Independent Spent Fuel Storage Installation, Revision to Correspondence Service List for Northern States Power - Minnesota ML23215A1672023-12-15015 December 2023 Acceptance of Requested Licensing Action Amendment Request to Revise Surveillance Requirement 3.8.1.2 Note 3 IR 05000282/20234012023-12-13013 December 2023 Security Baseline Inspection Report 05000282/2023401 and 05000306/2023401 L-PI-23-033, Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 32023-12-0505 December 2023 Supplement to License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3 ML23304A1632023-11-15015 November 2023 Supplemental Information Needed for Acceptance of Requested Licensing Action Amendment Request to Revise SR 3.8.1.2 Note 3 ML23319A3182023-11-15015 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation IR 05000282/20230032023-11-0808 November 2023 Integrated Inspection Report 05000282/2023003 and 05000306/2023003 ML23311A3572023-11-0707 November 2023 Core Operating Limits Report (COLR) for Prairie Island Nuclear Generating Plant (PINGP) Unit 2. Cycle 33. Revision 0 ML23285A3062023-10-12012 October 2023 Implementation of the Fleet Standard Emergency Plan for the Monticello Nuclear Generating Plant and the Prairie Island Nuclear Generating Plant ML23270B9022023-09-29029 September 2023 Review of Reactor Vessel Material Surveillance Program Capsule N Technical Report L-PI-23-025, License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 32023-09-28028 September 2023 License Amendment Request to Revise Technical Specification 3.8.1, Surveillance Requirement 3.8.1.2, Note 3 ML23265A2532023-09-26026 September 2023 Review of Reactor Vessel Material Surveillance Program Capsule N Technical Report ML23262B0372023-09-19019 September 2023 Response to NRC Request for Additional Information Regarding the 2023 Monticello and Prairie Island Plant Decommissioning Funding Status Reports ML23256A1682023-09-13013 September 2023 Independent Spent Fuel Storage Installation and Monticello Nuclear Generating Plant - Voluntary Security Clearance Program 2023 Insider Threat Program Self-Inspection L-PI-23-023, Baffle Former Bolts Alternate Aging Management Strategy2023-09-11011 September 2023 Baffle Former Bolts Alternate Aging Management Strategy IR 05000282/20230052023-08-30030 August 2023 Updated Inspected Plan for Prairie Island Nuclear Generating Plant Report 05000282/2023005 and 05000306/2023005 IR 05000282/20230102023-08-17017 August 2023 NRC Inspection Report 05000282/2023010 and 05000306/2023010 ML23222A0122023-08-10010 August 2023 Independent Spent Fuel Storage Installation and Monticello Nuclear Generating Plant - Changes in Foreign Ownership, Control or Influence IR 05000282/20230022023-08-0303 August 2023 Integrated Inspection Report 05000282/2023002 and 05000306/2023002 ML23214A2032023-08-0202 August 2023 Request for Information for an NRC Quadrennial Comprehensive Engineering Team Inspection: Inspection Report 05000282/2024010; 05000306/2024010 ML23206A2342023-07-25025 July 2023 Independent Spent Fuel Storage Installation, and Monticello Nuclear Generating Plant, Changes in Foreign Ownership, Control or Influence ML23202A0032023-07-21021 July 2023 Independent Spent Fuel and Independent Spent Fuel Storage Installation, Monticello Nuclear Generating Plant, Submittal of Quality Assurance Topical Report (NSPM-1) ML23199A0922023-07-18018 July 2023 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000306/2023004 ML23195A1732023-07-14014 July 2023 Revision of Standard Practice Procedures Plan L-PI-23-018, License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT2023-07-14014 July 2023 License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT ML23181A0192023-06-30030 June 2023 Independent Spent Fuel Storage Installation, Revision to Correspondence Service List for Northern States Power - Minnesota ML23178A2422023-06-28028 June 2023 Reassignment of the U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch III L-PI-23-006, License Amendment Request to Revise Technical Specification 3.7.8 Required Actions2023-06-22022 June 2023 License Amendment Request to Revise Technical Specification 3.7.8 Required Actions L-PI-23-016, 2022 10 CFR 50.46 LOCA Annual Report2023-06-14014 June 2023 2022 10 CFR 50.46 LOCA Annual Report IR 05000282/20234202023-06-0101 June 2023 Security Baseline Inspection Report 05000282/2023420 and 05000306/2023420 ML23150A1722023-05-30030 May 2023 Preparation and Scheduling of Operator Licensing Examinations 2024-02-01
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML23335A1152023-12-0101 December 2023 NRR E-mail Capture - Prairie Island Units 1 and 2 - Request for Additional Information LAR to Revise TS 3.7.8 Required Actions ML23248A3462023-09-0505 September 2023 NRR E-mail Capture - Request for Additional Information for Monticello Nuclear Generating Plant and Prairie Island Nuclear Generating Plant - Decommissioning Funding Status Reports ML23214A2032023-08-0202 August 2023 Request for Information for an NRC Quadrennial Comprehensive Engineering Team Inspection: Inspection Report 05000282/2024010; 05000306/2024010 ML23199A0922023-07-18018 July 2023 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000306/2023004 ML23096A3082023-04-0707 April 2023 Notification of Inspection an NRC Biennial Licensed Operator Requalification Program Inspection and Request for Information ML23055B0562023-02-27027 February 2023 Request for Information for NRC Commercial Grade Dedication Inspection Inspection Report 05000282/2023010 and 05000306/2023010 ML23053A1432023-02-22022 February 2023 Information Request to Support Upcoming Problem Identification and Resolution (Pi&R) Inspection at Prairie Island Nuclear Generating Plant ML22166A4112022-06-15015 June 2022 NRR E-mail Capture - Request for Additional Information Prairie Island Nuclear Generating Plant, Unit 2, Alternative RR-08, PIV Leakage ML22160A6022022-06-0909 June 2022 NRR E-mail Capture - Draft Request for Additional Information Prairie Island Nuclear Generating Plant, Units 1 and 2, 24-Month Operating Cycle Amendment ML22145A4152022-05-25025 May 2022 Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection 05000282/2022402 05000306/2022402 ML22131A2652022-05-11011 May 2022 NRR E-mail Capture - Request for Additional Information Xcel Energy Amendment Request to Create a Common Eplan and EOF for Monticello and Prairie Island ML22130A5792022-05-11011 May 2022 Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection ML21321A0452021-11-10010 November 2021 Request for Additional Information: Prairie Island 24-Month Cycle Amendment Request ML21305A0102021-10-29029 October 2021 NRR E-mail Capture - Request for Additional Information Prairie Island Cooling Water Amendment ML21252A0122021-08-30030 August 2021 NRR E-mail Capture - Request for Additional Information Amendment Request to Adopt TSTF-471 and 517-T for Prairie Island ML21147A5232021-06-0303 June 2021 Prarie Island Nuclear Generating Plant, Units 1 and 2 - Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection ML21131A0752021-05-10010 May 2021 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000282/2021004; 05000306/2021004 ML21099A0972021-04-0909 April 2021 Information Request to Support Upcoming Temporary Instruction 2515/194 Inspection; Inspection Report 05000282/2021012 and 05000306/2021012 ML21062A0532021-03-0202 March 2021 Information Request to Support Upcomng Problem Identification and Resolution (Pi&R) Inspection at the Prairie Island Nuclear Generating Plant ML21033A6112021-02-0101 February 2021 Request for Information for an NRC Triennial Baseline Design Bases Assurance Inspection (Team); Inspection Report 05000282/2021010 and 05000306/2021010 ML20343A1292020-12-0808 December 2020 NRR E-mail Capture - Request for Additional Information ML20192A1442020-07-0707 July 2020 NRR E-mail Capture - Request for Additional Information Prairie Island License Amendment Request to Adopt TSTF-505 ML20189A1782020-07-0606 July 2020 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000282/2020004; 05000306/2020004 ML20133K0692020-05-14014 May 2020 Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection ML20077K6242020-04-13013 April 2020 License Amendment Request - Request for Additional Information ML20052F4102020-02-21021 February 2020 Notification of Nrc Design Bases Assurance Inspection (Programs) (05000282/202010; 05000306/202010) and Initial Request for Information ML20035F1552020-02-0404 February 2020 NRR E-mail Capture - Request for Additional Information Monticello and Prairie Island Alternative Requests to Adopt Code Cases N-786-3 and N-789-3 (Epids: L-2019-LLR-0078 and L-2019-LLR-0079) ML19233A0032019-08-14014 August 2019 NRR E-mail Capture - Request for Additional Information Prairie Island Relief Requests 1-RR-10 and 2-RR-10 ML19057A1652019-02-26026 February 2019 NRR E-mail Capture - Request for Additional Information Prairie Island 50.69 Amendment Request ML18313A0832018-11-0707 November 2018 NRR E-mail Capture - Request for Additional Information Prairie Island NFPA-805 License Condition Modification Amendment Request ML18264A1912018-09-19019 September 2018 NRC Information Request (9/19/2018); Part B Items (Onsite) IP 71111.08 - E-Mailed 09/19/18 (DRS-M.Holmberg) ML18235A2982018-08-23023 August 2018 NRR E-mail Capture - Request for Additional Information Prairie Island TSTF-425 License Amendment Request ML18169A4202018-06-25025 June 2018 Supplemental Information Needed for Acceptance of Requested Licensing Action Amendment to Modify Renewed Facility Operating License Paragraph 2.C(4)(c) ML18025C0152018-01-24024 January 2018 Request for Information for an NRC Triennial Baseline Design Bases Assurance Inspection (Team): Inspection Report 05000282/2018011; 05000306/2018011 (DRS-A.Dunlop) ML17277B3332017-10-0404 October 2017 NRR E-mail Capture - Request for Additional Information Prairie Island Special Heavy Lifting Devices LAR ML17249A9232017-09-0606 September 2017 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000282/2017004; 05000306/2017004 (Exf) ML17235A9982017-08-23023 August 2017 NRR E-mail Capture - Request for Additional Information Prairie Island EAL Scheme Change ML17221A3892017-08-0909 August 2017 NRR E-mail Capture - Request for Additional Information for Prairie Island Nuclear Generating Plant License Amendment Request Dated February 23, 2017 Emergency Response Organization ML17219A0762017-08-0707 August 2017 NRR E-mail Capture - Request for Additional Information for Prairie Island Nuclear Generating Plant License Amendment Request Dated February 23, 2017 Emergency Response Organization ML17038A5132017-02-0707 February 2017 NRR E-mail Capture - Prairie Island NFPA 805 LAR, PRA RAI 21.01 ML17018A4272017-01-18018 January 2017 NRR E-mail Capture - Request for Additional Information: Prairie Island License Amendment Request to Revise Technical Specification 3.8.7 to Remove Non-Conservative Required Action ML16326A3532016-11-18018 November 2016 NRR E-mail Capture - Draft Request for Information Related to Prairie Island NFPA-805 License Amendment ML16265A1652016-09-20020 September 2016 Notification of an NRC Triennial Heat Sink Performance Inspection and Request for Information; Inspection Report 05000282/2016004; 05000306/2016004 (Gfo) ML16189A2052016-07-0707 July 2016 Notification of NRC Inspection and Request for Information ML16113A1612016-04-21021 April 2016 Information Request to Support Upcoming Problem Identification and Resolution (Pi&R) Inspection at Prairie Island Nuclear Generating Plant, Units 1 and 2 ML16075A0802016-03-15015 March 2016 NRR E-mail Capture - Prairie Island Nuclear Generating Plant, Units 1 and 2 Request for Additional Information Related to License Amendment Request to Adopt TSTF-523, GL 2008-01, Managing Gas Accumulation ML16008A1092016-01-0808 January 2016 NRR E-mail Capture - Prairie Island Nuclear Generating Plant, Units 1 and 2 - Requests for Additional Information (Afpb) License Amendment Request to Adopt NFPA 805 ML15195A6562015-07-10010 July 2015 Prairie Island Notification of NRC Inspection and Request for Information ML15149A1662015-05-28028 May 2015 Plan - Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection (Mxg) ML15121A6512015-04-29029 April 2015 Request for Information for an NRC Triennial Baseline Component Design Bases Inspection (CDBI) Inspection Report 05000282/2015007; 05000306/2015007 (Jen) 2023-09-05
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 October 17, 2008 Mr. Michael D. Wadley Site Vice President Prairie Island Nuclear Generating Plant Northern States Power-Minnesota 1717 Wakonade Drive East Welch, MN 55089 SUB~IECT: PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 REQUEST FOR ADDITIONAL INFORMATION RELATED TO LICENSE AMENDMENT REQUEST FOR TECHNICAL SPECIFICATIONS CHANGES TO ALLOW USE OF WESTINGHOUSE 0.422-INCH OD 14X14 VANTAGE+ FUEL (TAC NOS. MD9142 AND MD9143)
Dear Mr. Wadley:
By letter to the U.S. Nuclear Regulatory Commission (NRC) dated June 26, 2008, as supplemented by letters dated August 4 and August 26,2008, Nuclear Management Company, LLC, submitted a request for Technical Specifications changes to allow the use of Westinghouse 0.422-inch outside diameter (OD) 14X14 VANTAGE+ fuel for Prairie Island Nuclear Generating Plant, Units 1 and 2.
The NRC staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter. During a discussion with your staff on October 6, 2008, it was agreed that you would provide a response within 30 days of the date of this letter.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-4037.
Sincerely, Thomas J. Wengert, Senior Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-282 and 50-306
Enclosure:
Request for Additional Information cc w/encl: Distribution via ListServ
REQUEST FOR ADDITIONAL INFORMATION (RAI)
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 DOCKET NOS. 50-282 AND 50-306 In reviewing the Nuclear Management Company, LLC (NMC), submittal dated June 26, 2008, as supplemented by letters dated August 4 and August 26,2008, which requested technical specification changes related to a change in fuel type from Westinghouse OAOO-inch outside diameter (OD) Vantage+ (400V+) fuel to Westinghouse OA22-inch OD Vantage+ (422V+) fuel for the Prairie Island Nuclear Generating Plant, Units 1 and 2, the U.S. Nuclear Regulatory Commission (NRC) staff has determined that the following information is needed in order to complete its review:
The license amendment request included a revisitation of the accident and transient analyses, some of which were re-analyzed, and the loss-of-coolant accident (LOCA) analyses, which were affected by the requested fuel transition.
- 1. Page 1-7, Table 1-1 of the PINGP 422V+ Reload Licensing Report states, "The power uncertainty was reduced to account for installation of a more accurate flow measurement system used in the power measurement. The [Revised Thermal Design Procedure (RTDP)] analyses completed within this report were thus completed at a bounding high power level to confirm acceptable operation at any power level, including measurement uncertainties of 0.5 percent or more, up to 1,683 [megawatts thermal (MWt)]." Please justify the uncertainty reduction:
- a. Explain what flow measurement system was installed.
- b. Provide reference to applicable supporting documentation, such as topical reports describing the flow measurement system.
- c. Briefly describe the flow measurement system installation and calibration process.
- 2. The information contained in Table 1-1, discussed in RAI 1 above, appears slightly inconsistent with the information contained in Table 4-1, on Page 4-8, of the licensing report, which states, "A power level of 1,677 MWt has been used for all RTDP thermal hydraulic design analyses. For analyses explicitly modeling parameter uncertainties, a power level of 1,683 MWt was used." Please provide additional information about the analytic incorporation of power uncertainty to bring these two statements into clearer alignment.
- 3. Page 4-4 of the licensing report states "There is a maximum g.O-percent transition core
[departure from nucleate boiling ratio (DNBR)] penalty for the 400V+ fuel which will be offset by a 6.0-percent [FdH] reduction in burned 400V+ fuel based on a conservative 1.5-percent DNBR: 1-percent [FdH] sensitivity." This treatment of DNBR margin trade-off is presented as axiomatic; however, the !\IRC staff is unfamiliar with this sensitivity.
Please provide a basis for this statement.
- a. Reference an appropriate licensing topical report where this sensitivity is described.
ENCLOSURE
-2
- b. If the sensitivity is not discussed in a licensing topical report, please provide a phenomenological discussion of the peaking behavior of previously irradiated fuel and explain how the changes in peaking behavior result in increased DNBR margin.
- c. Presumably, the steady-state peaking effects of previously irradiated fuel that result in a DNBR margin increase are propagated through DNBR transient analyses. Is the margin increase observed above based on a steady-state or transient power shape?
- 4. Table 4-3 on Page 4-10 of the licensing report lists a 15 psi increase in RTDP pressure uncertainty; however, the NRC staff was unable to locate a discussion of this increase in the licensing report. Please explain.
- 5. Section 5.1 of the licensing report discusses the Rod Withdrawal Accident from a Subcritical Condition. An isothermal temperature coefficient of +5 pcm/oF is assumed, and the accident initiates at 54rF. As a part of the justification for these assumptions, the licensing report states, "...after the initial neutron flux peak, the isothermal temperature coefficient can affect the succeeding rate of power increase." Regarding the selection of parameters affecting heat transfer, the analysis is designed so that it "yields a larger peak heat flux."
- a. Confirm whether the assumed isothermal temperature coefficient is bounding of that at lower assumed temperatures.
- b. Explain how the effect of selecting input conditions to maximize heat flux results in a conservative hot rod fuel temperature, or how other input assumptions correct or compensate for the maximized heat flux.
- 6. The introduction of larger fuel assemblies will reduce the volume of water in the core.
Thus, a chemical and volume control system malfunction could dilute the core more rapidly. Confirm that the assumed reactivity insertion rate associated with a boron dilution is bounding for the 422V+ core, which will have a reduced volume.
- 7. The reactor coolant pump locked rotor/shaft break analysis presents hot spot cladding inner temperature as a function of time. This result is attained based on standard Westinghouse analytic assumptions used to maximize fuel energy delivery to the cladding.
- a. Why is fuel centerline temperature not an acceptance criterion for this postulated accident scenario?
- b. How is the fuel centerline temperature affected by the assumptions discussed above?
- c. What is the predicted peak fuel centerline temperature for this accident?
- 8. Page 5-72 of the licensing report discusses the triviality of differences arising from postulating a LOCA in a transition core as opposed to the analyzed equilibrium 422V+
core. It is stated, "Even for larger [small-break loss-of-coolant accidents (SBLOCAs)],
the thermal-hydraulic response is quasi-one dimensional ... " This statement is offered to
-3 assess the significance of the potential for flow redistribution between the 400V+ and the 422V+ fuel assemblies. Presumably, the quasi-one dimensionality of transition cores has been assessed. Please provide a summary of this assessment to help substantiate the quasi-one dimensionality claim.
- 9. In consideration of the Westinghouse position on loop seal plugging, the licensing report discusses the effects that gaps between the core barrel upper plenum nozzles and the vessel may have on the effectiveness of vapor relief. Please provide an assessment of this statement in terms of the figures of merit discussed in the 1997 report, NSD-NRC 97-5092, "Core Uncovery Due to Loop Seal Re-Plugging During Post-LOCA Recovery."
Particularly, consider some of the stable or unstable core uncovery envelopes, and evaluate the effects of a change in K1A 2 would have on the core uncovery envelopes.
Mr. lVIichael D. Wadley October 17, 2008 Site Vice President Prairie Island Nuclear Generating Plant Northern States Power-Minnesota 1717 Wakonade Drive East Welch, MN 55089
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 REQUEST FOR ADDITIONAL INFORMATION RELATED TO LICENSE AMENDMENT REQUEST FOR TECHNICAL SPECIFICATIONS CHANGES TO ALLOW USE OF WESTINGHOUSE 0.422-INCH OD 14X14 VANTAGE+ FUEL (TAC NOS. MD9142 AND MD9143)
Dear Mr. Wadley:
By letter to the U.S. Nuclear Regulatory Commission (NRC) dated June 26, 2008, as supplemented by letters dated August 4 and August 26,2008, Nuclear Management Company, LLC, submitted a request for Technical Specifications changes to allow the use of Westinghouse 0.422-inch outside diameter (OD) 14X14 VANTAGE+ fuel for Prairie Island Nuclear Generating Plant, Units 1 and 2.
The NRC staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter. During a discussion with your staff on October 6, 2008, it was agreed that you would provide a response within 30 days of the date of this letter.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRC's goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-4037.
Sincerely, lRAI Thomas J. Wengert, Senior Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-282 and 50-306
Enclosure:
Request for Additional Information cc w/encl: Distribution via ListServ DISTRIBUTION:
PUBLIC LPL3-1 RIF RidsNrrDorlLpl3-1 Resource RidsNRRPMTWengert Resource RidsNrrLATHarris Resource RidsNrrDssSrxb Resource RidsAcrsAcnw_MailCTR Resource RidsOgcRp Resource B. Parks, NRR RidsRgn3MailCenter Resource RidsNrrDorlDpr Resource ADAMS Accession Number' ML082810645 OFFICE LPL3-1/PM LPL3-1/LA NRRIDSS/SR2SB/BC LPL3-1/BC NAME TWengert 'Arv THarris .) tit Gcranston/~ ',..,(/}J LJames (/~
DATE 10!\~ 108 l 1011 108 10tff 108 101l:r+o8 V OFFICIAL RECORD COpy