ADAMS Accession Number ML: 18264A191 Part B Items (Onsite) - NRC Information Request (9/19/2018) - IP 71111.08 - Prairie Island Nuclear Plant Unit 1 - Documents Selected for Onsite Review.

Please provide a hard copy of the documents below to the NRC Onsite work location or Resident Office on or before the entrance meeting scheduled for September 26, 2018. This list of documents compliments/supplements the existing list of information requested for the onsite review as identified in Section B of the NRC request for information letter dated June 5, 2018. Please direct questions on this request to the lead inspector Mel Holmberg at msh@nrc.gov or 630 829-9748.

1) ITEM B.1 - See detailed list of information needed in the NRC information request letter-Welds selected for review (prior outage)

Work Order Description/Topic Supporting Docs 535855-01, 535854-01,13,27 Replaced piping segment to accommodate installation of new vent lines for voids found in RHR system.

As stated in Item B.1 of request letter and EC-26588 388028-01 Replaced SG Blowdown Valve As stated in Item B.1 of request letter

2) ITEM B.2 of NRC information request letter-ISI related corrective actions AR Number Description/Topic Supporting Docs 501000012442 And any other ARs that relate to WE Part 21

- Event Notice 53422 RPV Head Upper Thermal Sleeve Wear-affecting WE PWRs as described in We vendor-TB-07-2 and NSAL-18-1 and MRP Letter 2018-033 Copy of AR and all CAs and applicable evaluations including applicable nondestructive examination (NDE) reports.

ARs that relate to this topic.

Copy of MRP 2017-011 Baffle Former Bolt Cracking-PWRs Copy of AR and all CAs and applicable evaluations including applicable NDE reports.

500001538861 SP 1392 Bolted Connections ISI Indication Copy of AR and all CAs and applicable evaluations including applicable NDE reports.

501000001978 Spare RHR Pump missed ASME XI Repair Req Copy of AR and all CAs and applicable evaluations including applicable NDE reports.

500001540887 SP 1168.13 Active leak Sl-145-2 Copy of AR and all CAs and applicable evaluations including applicable NDE reports.

501000011605 Risk Failure to Perform Pressure Test Copy of AR and all CAs and applicable evaluations including applicable NDE reports.

500001539956 1R30: 12 RCP 12 (145-052)

NDE Non-Relevant Copy of AR and all CAs and applicable evaluations including applicable NDE reports.