Thomas A. Conboy
Site Vice President
Prairie Island Nuclear Generating Plant
Northern States Power Company, Minnesota
1717 Wakonade Drive East
Welch, MN 55089-9642
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNIT 2 - NOTIFICATION
OF NRC BASELINE INSPECTION AND REQUEST FOR INFORMATION;
INSPECTION REPORT 05000306/2023004
Dear Thomas A. Conboy:
On October 2, 2023, the U.S. Nuclear Regulatory Commission (NRC) will begin the Baseline
Inservice Inspection Procedure 71111.08. This onsite inspection is scheduled to be performed
October 2 through 6, 2023 and October 10 through 13, 2023.
Experience has shown that this inspection is resource intensive both for the NRC inspector and
your staff. In order to minimize the impact to your onsite resources, and to ensure a productive
inspection for both sides, we have enclosed a request for documents needed for this inspection.
These documents have been divided into two groups.
The first group identifies information necessary to ensure that the inspector is adequately
prepared. The second group identifies the information the inspector will need upon arrival at the
site. It is important that all of these documents are up-to-date, and complete, in order to
minimize the number of additional documents requested during the preparation and/or the
onsite portions of the inspection.
We have discussed the schedule for inspection activities with your staff and understand that our
regulatory contact for this inspection will be Nathan A. Fedora, of your organization. If there are
any questions about this inspection or the material requested, please contact the lead inspector
John V. Bozga at 630-829-9613.
This letter does not contain new or amended information collection requirements subject to the
Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
requirements were approved by the Office of Management and Budget, Control
Number 3150-0011. The NRC may not conduct or sponsor, and a person is not required to
respond to, a request for information or an information collection requirement unless the
requesting document displays a currently valid Office of Management and Budget Control
Number.
July 18, 2023
T. Conboy
2
This letter and its enclosure will be made available for public inspection and copying at
http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in
accordance with Title 10 of the Code of Federal Regulations, Part 2.390, Public Inspections,
Exemptions, Requests for Withholding.
Sincerely,
John V. Bozga, Senior Reactor Inspector
Engineering and Reactor Projects Branch
Division of Operating Reactor Safety
Docket No. 50-306
License No. DPR-60
Enclosure:
Document Request for
Inservice Inspection
cc: Distribution via LISTSERV
Signed by Bozga, John
on 07/18/23
T. Conboy
3
Letter to Thomas A. Conboy from John V. Bozga dated July 18, 2023.
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNIT 2 - NOTIFICATION
OF NRC BASELINE INSPECTION AND REQUEST FOR INFORMATION;
INSPECTION REPORT 05000306/2023004
DISTRIBUTION:
RidsNrrPMPrairieIsland Resource
RidsNrrDorlLpl3
RidsNrrDroIrib Resource
R3-DORS
ADAMS Accession Number: ML23199A092
Publicly Available
Non-Publicly Available
Sensitive
Non-Sensitive
OFFICE
RIII
NAME
JBozga:sw
DATE
07/18/2023
OFFICIAL RECORD COPY
DOCUMENT REQUEST FOR INSERVICE INSPECTION
Enclosure
Inspection Report: 05000306/2023004
Inspection Dates:
October 2 through 6 2023 and October 10 through 13, 2023
Inspection Procedures:
Inspection Procedure 71111-08, Inservice Inspection
Lead Inspector:
John V Bozga, DORS
630-829-9613
A.
Information for the In-Office Preparation Week
The following information (electronic copy) is requested by September 22, 2023, to
facilitate the selection of specific items that will be reviewed during the onsite inspection
week. The inspector will select specific items from the information requested below and
request a list of additional documents needed onsite to your staff. We request that the
specific items selected from the lists be available and ready for review on the first day of
inspection. The following information is applicable to the outage Unit unless otherwise
indicated. If you have any questions regarding this information, please call the inspector
as soon as possible.
1.
For the upcoming outage, a detailed schedule and description of:
a.
Non-Destructive Examinations (NDEs) planned for Class 1 and 2 Systems and
containment, performed as part of your American Society of Mechanical
Engineers (ASME) Code Inservice Inspection (ISI) Program (include edition and
addenda of Code committed to), and NDEs planned for other systems
performed as part of a Risk-Informed ISI Program, or other augmented
inspection programs (e.g., ASME Code Case N-770 examination of dissimilar
metal welds and examinations to meet an industry initiative);
b.
Reactor vessel upper head examinations required by Title 10 of the Code of
Federal Regulations (CFR), Part 50.55a(g)(6)(ii)(D) and Code Case N-729;
c.
Steam generator (SG) tube inspection and repair activities for the upcoming
outage or SG secondary side examinations1; and
d.
Welding on Code Class 1, 2, or 3 components. For each weld examination,
include the weld identification number, description of weld (component name),
category, class, type of exam and procedure number, and date of examination.
2.
A copy of the NDE procedures, SG eddy current examination (ET) acquisition and
analysis procedures, and welding procedures used to perform the activities
identified in Item A.1 (including NDE calibration and flaw characterization/sizing
1 Note 1- If no SG examinations are planned for this outage, please confirm when the next SG examination will occur
and no further information is required for the items identified above requesting SG related information.
DOCUMENT REQUEST FOR INSERVICE INSPECTION
2
procedures and Welding Procedure Qualification Records). For ultrasonic
examination procedures qualified in accordance with Appendix VIII, of Section XI of
the ASME Code, provide documentation supporting the procedure qualification
(e.g., the Electric Power Research Institute performance demonstration qualification
summary sheets). For SG tube ET this includes the acquisition and analysis
procedures.
3.
A copy of ASME Section XI, Code Relief Requests applicable to the examinations
identified in Item A.1.
4.
A copy of the 10-year ISI Program showing those required exams scheduled to be
performed this outage, and those which have been completed.
5.
A list identifying NDE reports (ultrasonic, radiography, magnetic particle, or dye
penetrant), which have identified relevant indications on Code Class 1 and 2
Systems since the beginning of the last refueling outage.
6.
List of repair/replacement welds in Code Class 1, 2, and 3 Systems, which have
been fabricated since the beginning of the last refueling outage and identify the
system, weld number, and reference applicable documentation (e.g., NIS-2 forms
with definitions of system and component acronyms).
7.
List of reactor vessel weld examinations required by the ASME Code that are
scheduled to occur during the upcoming refueling outage, and please provide a
detailed description of the welds and the extent of the planned examination.
8.
Corrective action list of ISI and SG-related issues such as piping or SG tube
degradation or damage (e.g., cracks, wall thinning, wear, microbiologically induced
corrosion) or errors identified during piping/SG tube examinations since the
beginning of the last refueling outage. Also, include a list of corrective actions
associated with foreign material in the reactor vessel, primary coolant system, SG,
or feed systems since the beginning of the last refueling outage.
9.
10 CFR Part 21 reports applicable to your structures, systems, or components
within the scope of ASME Code Section XI that have been identified since the
beginning of the last refueling outage.
10.
Copy of SG history documentation given to vendors performing ET of the SGs
during the upcoming outage1.
11.
Copy of procedure containing screening criteria used for selecting tubes for
in-situ pressure testing and the procedure to be used for in-situ pressure testing1.
12.
Copy of previous outage SG tube operational assessment completed following ET
of the SGs (provide this document even if no SG ET is planned for current outage).
13.
Copy of most recent SG Degradation Assessment (provide this document even if
no SG ET is planned for current outage).
1 Note 1- If no SG examinations are planned for this outage, please confirm when the next SG examination will occur
and no further information is required for the items identified above requesting SG related information.
DOCUMENT REQUEST FOR INSERVICE INSPECTION
3
14.
Copy of most recent SG Condition Monitoring Assessments1.
15.
Copy of the document defining the planned SG ET scope (e.g., 100 percent of
unrepaired tubes with bobbin probe and 20 percent sample of hot leg expansion
transition regions with rotating probe) and identify the scope expansion criteria,
which will be applied. Also identify and describe any deviations in this scope or
expansion criteria from the Electric Power Research Institute Guidelines1.
16.
Copy of the document describing the ET acquisition equipment to be applied
including ET probe types. Also identify the extent of planned tube examination
coverage with each probe type (e.g., rotating probe - 0.080 inches, 0.115 inches
pancake coils and mid-range + point coil applied at the top-of-tube-sheet plus
3 inches to minus 12 inches)1.
17.
Provide procedures with guidance/instructions for identifying (e.g., physically
locating the tubes that require repair) and plugging SG tubes1.
18.
Identify and quantify any SG tube leakage experienced during the previous
operating cycle. Also provide documentation identifying which SG was leaking and
corrective actions completed or planned for this condition.
19.
Point of contact information (name and site number) for the following activities:
a.
ISISite and vendor leads
b.
Boric Acid Inspections and Evaluations
c.
Reactor Vessel Head InspectionSite and vendor leads
d.
SG InspectionSite and vendor leads
e.
Aging Management Programs
f.
Site Welding Engineer
B.
Onsite Information to be Provided to the Inspector on the First Day of the
Inspection (e.g., Following the Entrance Meeting). Please Provide Hard Copies
(e.g., Paper Records) of the Following Documents.
1.
For welds selected by the inspector from Item A.1.d and A.6 above, provide
copies of the following documents:
a.
Document of the weld number and location (e.g., system, train, branch);
b.
Document with a detail of the weld construction (e.g., drawing);
c.
Applicable portions of the Design Specification and applicable Code of
construction for the weldment (e.g., B31.1 or ASME Section III);
1 Note 1- If no SG examinations are planned for this outage, please confirm when the next SG examination will occur
and no further information is required for the items identified above requesting SG related information.
DOCUMENT REQUEST FOR INSERVICE INSPECTION
4
d.
Applicable Code Edition and Addenda for weld procedure qualification;
e.
Applicable weld procedure specifications and weld data sheets used to fabricate
the welds;
f.
Copies of procedure qualification records supporting the weld procedure
specifications;
g.
Copies of welders performance qualification records;
h.
Copies of mechanical test reports identified in the weld procedure qualification
records above;
i.
Copies of the nonconformance reports for the selected welds;
j.
Access to radiographs and equipment to view radiographs of the selected welds;
k.
ASME Code Section XI repair replacement plan and reconciliation for
replacement components/materials;
l.
Certified Material Test Reports for replacement pressure boundary materials;
and
m. Copies of the NDE required by the construction Code and the pre-service
examination records required by the ASME Code Section XI for the selected
2.
For the ISI-related corrective action issues selected by the inspector from Item A.8
above, provide a copy of the corrective actions and supporting documentation.
3.
For the NDE reports with relevant indications on Code Class 1 and 2 Systems
selected by the inspector from Item A.5 above, provide a copy of the examination
records and associated corrective action documents.
4.
Updated schedules for Item A.1 (including schedule showing contingency
repair plans if available).
5.
Fabrication Drawings (D size) of the reactor vessel welds (including vessel head
J-groove welds) if any are to be examined during the outage. Also provide any
drawings used by NDE vendors to locate these welds.
6.
Copy of the procedures which govern the scope, equipment used, and
implementation of the inspections required to identify boric acid leakage from
systems and components above the vessel head.
7.
Copy of:
a.
Engineering evaluations/assessments of boric acid related deposits and
associated wastage or corrosion for safety-related components; and
DOCUMENT REQUEST FOR INSERVICE INSPECTION
5
b.
Corrective action records for coolant leakage including boric acid deposits on
safety-related components identified since the beginning of the last refueling
outage.
8.
Copy of the plant procedures used to perform inspections to identify reactor coolant
system leaks or boric acid deposits and the procedures for resolution of leaks or
boric acid deposits.
9.
Copy of the documents which demonstrate that the procedures to be used for
volumetric examination of the reactor vessel head penetration J-groove welds were
qualified by a blind demonstration test in accordance with
10 CFR Part 50.55a(g)(6)(ii)(D).
10. Copy of volumetric, surface, and visual examination records for the prior inspection
of the reactor vessel head and head penetration J-groove welds.
11. Provide a copy of the Electric Power Research Institute Examination Technique
Specification Sheets and vendor related documents, which support qualification of
the ET probes to be used during the upcoming SG tube inspections1.
12. Provide a copy of the guidance to be followed if a loose part or foreign material is
identified in the SGs1.
13. Identify the types of SG tube repair processes which will be implemented for
defective SG tubes (including any U.S. Nuclear Regulatory Commission
reviews/evaluation/approval of this repair process). Provide the flaw depth sizing
criteria to be applied for ET indications identified in the SG tubes1.
14. Copy of document describing actions to be taken if a new SG tube degradation
mechanism is identified1.
15. Provide document which defines the scope of SG secondary side examinations
(if any are planned) and identify site specific operational history related to
degradation of SG secondary side components (if any).
16. Provide procedures with guidance/instructions for identifying (e.g., physically
locating the tubes that require repair) and plugging SG tubes1.
17. Provide copies of the following standards at the onsite U.S. Nuclear Regulatory
Commission inspection location for the duration of the inspection:
a.
Sections V, IX, and XI of the ASME Code with Editions applicable to the ISI
Program and the Repair/Replacement Program;
1 Note 1- If no SG examinations are planned for this outage, please confirm when the next SG examination will occur
and no further information is required for the items identified above requesting SG related information.
DOCUMENT REQUEST FOR INSERVICE INSPECTION
6
b.
Copy of the performance demonstration initiative (PDI) generic procedures with
the latest applicable revisions that support site qualified ultrasonic examination
of piping welds and components (e.g., PDI-UT-1, PDI-UT-2, PDI-UT-3,
PDI-UT-10 etc.);
c.
Electric Power Research Institute and industry standards referenced in the site
procedures used to perform the SG tube ET, which includes Electric Power
Research Institute documents: SG Examination Guidelines, SG Integrity
Assessment Guidelines, SG In-Situ Pressure Test Guidelines1; and
d.
Boric Acid Corrosion Guidebook Revision 1Electric Power Research Institute
Technical Report 1000975.
If you have questions regarding the information requested, please contact the lead inspector.
1 Note 1- If no SG examinations are planned for this outage, please confirm when the next SG examination will occur
and no further information is required for the items identified above requesting SG related information.