MONTHYEARL-PI-08-047, License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+ Fuel2008-06-26026 June 2008 License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+ Fuel Project stage: Request ML0822101322008-07-22022 July 2008 Email - Prairie Island Acceptance Review Questions for LAR to Allow Use of West. 14X14 Vantage+ Fuel (TACs MD9142/MD9143) Project stage: Acceptance Review ML0820605722008-07-28028 July 2008 Request for Supplemental Information, Acceptance Review of License Amendment Request Project stage: Acceptance Review L-PI-08-071, Supplement to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel2008-08-26026 August 2008 Supplement to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel Project stage: Supplement ML0822614492008-08-28028 August 2008 Acceptance of Requested Licensing Action Technical Specification Changes to Allow Use of Westinghouse 0.422-inch OD 14X14 Vantage+ Fuel Project stage: Acceptance Review ML0828106452008-10-17017 October 2008 Request for Additional Information Related to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage+Fuel (Tac No. MD9142, MD9143) Project stage: RAI L-PI-08-096, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse. 0.422- Inch OD 14x14 Vantage + Fuel2008-11-14014 November 2008 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse. 0.422- Inch OD 14x14 Vantage + Fuel Project stage: Response to RAI ML0833002102008-12-15015 December 2008 Request for Additional Information Related to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage + Fuel (TAC Nos. MD9142/9143) Project stage: RAI ML0835200472008-12-30030 December 2008 Request Withholding Information from Public Disclosure for Prairie Island Nuclear Generating Plant, Units 1 and 2 (Tac Nos. MD9142 and MD9143) Project stage: Other ML0835800982009-01-12012 January 2009 Request for Additional Information Related to License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage + Fuel (TAC Nos. MD9142/9143) Project stage: RAI L-PI-09-011, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel2009-01-30030 January 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel Project stage: Response to RAI L-PI-09-022, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel2009-02-0909 February 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+ Fuel Project stage: Response to RAI ML0901403342009-02-11011 February 2009 RAI for TS Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+Fuel Project stage: RAI L-PI-09-025, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage+ Fuel2009-02-20020 February 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage+ Fuel Project stage: Response to RAI L-PI-09-034, Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage + Fuel2009-03-12012 March 2009 Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage + Fuel Project stage: Response to RAI ML0907210882009-03-12012 March 2009 Enclosure 1, Non-Proprietary Responses to Requests for Additional Information License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 422V+ Fuel Project stage: Response to RAI ML0907102152009-03-25025 March 2009 Request for Withholding Information from Public Disclosure for Prairie Island Nuclear Generating Plant, Units 1 and 2 Project stage: Withholding Request Acceptance L-PI-09-066, 422V+Fuel Transition Project RAI Response-EMCB RAI-1(a)2009-04-27027 April 2009 422V+Fuel Transition Project RAI Response-EMCB RAI-1(a) Project stage: Other L-PI-09-065, Supplemental Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+Fuel2009-05-0404 May 2009 Supplemental Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14x14 Vantage+Fuel Project stage: Supplement ML0913103842009-05-0404 May 2009 Clarification of Response to Request for Additional Information Regarding License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch 14x14 Vantage+ Fuel Project stage: Response to RAI ML0914905612009-06-0808 June 2009 Request for Withholding Information from Public Disclosure for Prairie Island Nuclear Generating Plant, Units 1 and 2 Project stage: Withholding Request Acceptance ML0917402012009-06-25025 June 2009 Public Letter Draft Safety Evaluation for License Amendment Request for Technical Specifications Changes to Allow Use of Westinghouse 0.422-inch OD 14x14 Vantage+ Fuel Project stage: Draft Approval ML0914608092009-07-0101 July 2009 Issuance of Amendments Technical Specifications Changes to Allow Use of Westinghouse 0.422-Inch OD 14X14 Vantage + Fuel Project stage: Approval ML0922403322009-08-31031 August 2009 Correction to Safety Evaluation Supporting Amendment Nos. 192 and 181 Technical Specification Changes to Allow Use of Westinghouse 0.422-Inch OD 14 X 14 Vantage+ Fuel (TAC Nos. MD9142/MD9143) Project stage: Approval ML0925703672009-09-15015 September 2009 Correction to Technical Specifications (TAC Nos. MD9142 and MD9143) Project stage: Other 2009-02-11
[Table View] |
|
---|
Category:Letter
MONTHYEARML24298A0552024-10-30030 October 2024 Response to Alternative RR-10, Auxiliary Feedwater Valve Testing IR 05000282/20244032024-10-25025 October 2024 – Security Baseline Inspection Report 05000282/2024403 and 05000306/2024403 05000282/LER-2024-001-01, Auxiliary Building Special Ventilation System Inoperable During Movement of Irradiated Fuel Assemblies2024-10-22022 October 2024 Auxiliary Building Special Ventilation System Inoperable During Movement of Irradiated Fuel Assemblies L-PI-24-044, Application to Revise Technical Specifications to Adopt TSTF-591, Revise Risk Informed Completion Time (RICT) Program2024-10-21021 October 2024 Application to Revise Technical Specifications to Adopt TSTF-591, Revise Risk Informed Completion Time (RICT) Program ML24277A1012024-10-0303 October 2024 Closure of Interim Report of a Potential Deviation or Failure to Comply Associated with Bentley Systems Incorporated Autopipe Software ML24221A3622024-09-27027 September 2024 Issuance of Amendment Nos. 245 and 233 Revise Technical Specification 3.8.1, AC Sources-Operating, Surveillance Requirement 3.8.1.2, Note 3 ML24241A1682024-09-23023 September 2024 Transmittal Letter Amendment No. 13 to Materials License No. Special Nuclear Material-2506 for the Prairie Island Independent Spent Fuel Storage Installation 05000282/LER-2024-001, Auxiliary Building Special Ventilation System Inoperable During Movement of Irradiated Fuel Assemblies2024-09-16016 September 2024 Auxiliary Building Special Ventilation System Inoperable During Movement of Irradiated Fuel Assemblies IR 05000282/20243012024-09-13013 September 2024 NRC Initial License Examination Report 05000282/2024301 and 05000306/2024301 IR 05000282/20240052024-08-28028 August 2024 Updated Inspection Plan and Assessment Follow-Up Letter for Prairie Island Nuclear Generating Plant, Units 1 and 2 (Report 05000282/2024005 and 05000306/2024005) L-PI-24-040, Post-Submittal Package Letter2024-08-23023 August 2024 Post-Submittal Package Letter IR 05000282/20245012024-08-0505 August 2024 Emergency Preparedness Inspection Report 05000282/2024501 and 05000306/2024501 ML24213A1592024-07-31031 July 2024 Operator Licensing Examination Approval - Prairie Island Nuclear Generating Plant IR 05000282/20240022024-07-30030 July 2024 Integrated Inspection Report 05000282/2024002 and 05000306/2024002 ML24208A1502024-07-26026 July 2024 Independent Spent Fuel Storage Installation - Submittal of Quality Assurance Topical Report (NSPM-1) ML24197A2012024-07-15015 July 2024 Notification of NRC Baseline Inspection and Request for Information; Inspection Report 05000282/2024004 IR 05000282/20240102024-06-28028 June 2024 Comprehensive Engineering Team Inspection Report 05000282/2024010 and 05000306/2024010 L-PI-24-036, – Preparation and Scheduling of Operator Licensing Examinations2024-06-28028 June 2024 – Preparation and Scheduling of Operator Licensing Examinations ML24158A5912024-06-0606 June 2024 CFR 50.46 LOCA Annual Report L-PI-24-031, Independent Spent Fuel Storage Installation, Supplement to License Amendment Request to Revise Independent Spent Fuel Storage Installation (ISFSI) License Conditions 23(a), 24(A)(2), and 24(B)(2)2024-06-0505 June 2024 Independent Spent Fuel Storage Installation, Supplement to License Amendment Request to Revise Independent Spent Fuel Storage Installation (ISFSI) License Conditions 23(a), 24(A)(2), and 24(B)(2) L-PI-24-014, License Amendment Request to Revise the Technical Specification Definition of Reactor Trip System (RTS) Response Time and Apply Response Time Testing to RTS Trip Functions with Time Delay Assumption2024-06-0303 June 2024 License Amendment Request to Revise the Technical Specification Definition of Reactor Trip System (RTS) Response Time and Apply Response Time Testing to RTS Trip Functions with Time Delay Assumption 05000306/LER-2024-001-01, Reactor Trip and Auto-Start Actuation of Auxiliary Feedwater Due to Loss of Suction to the 22 Main Feedwater Pump2024-05-31031 May 2024 Reactor Trip and Auto-Start Actuation of Auxiliary Feedwater Due to Loss of Suction to the 22 Main Feedwater Pump ML24155A1922024-05-31031 May 2024 Refueling Outage Unit 2 R33 Owners Activity Report for Class 1, 2, 3 and Mc Inservice Inspections ML24262A1992024-05-29029 May 2024 L-PI-24-018 PINGP 75 Day Letter ML24149A3712024-05-29029 May 2024 (Ping) - Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection L-PI-24-030, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.8.12024-05-22022 May 2024 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 3.8.1 ML24141A1292024-05-22022 May 2024 Northern States Power Company - Use of Encryption Software for Electronic Transmission of Safeguards Information ML24141A0452024-05-20020 May 2024 Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection ML24128A2572024-05-16016 May 2024 ISFSI A13 Acceptance Letter IR 05000282/20240012024-05-15015 May 2024 Integrated Inspection Report 05000282/2024001 and 05000306/2024001 ML24130A2362024-05-0909 May 2024 Independent Spent Fuel Storage Installation - 2023 Annual Radiological Environmental Monitoring Program Report ML24130A2392024-05-0909 May 2024 2023 Annual Radioactive Effluent Report ML24071A1162024-05-0101 May 2024 Issuance of Amendment Nos. 244 and 232 Revise TS 3.7.8, Cooling Water (Cl) System ML24128A0882024-04-30030 April 2024 Submittal of Updated Safety Analysis Report (Usar), Revision 38 05000306/LER-2024-001, Reactor Trip and Auto-Start Actuation of Auxiliary Feedwater Due to Loss of Suction to the 22 Main Feedwater Pump2024-04-29029 April 2024 Reactor Trip and Auto-Start Actuation of Auxiliary Feedwater Due to Loss of Suction to the 22 Main Feedwater Pump ML24089A2382024-04-29029 April 2024 Summary of Nuclear Property Insurance IR 05000282/20244012024-04-25025 April 2024 – Security Baseline Inspection Report 05000282/2024401 and 05000306/2024401 ML24100A8042024-04-24024 April 2024 – Alternative Request RR-09 for Safety Injection and Volume Control System Category C Check Valve Inservice Testing ML24114A0882024-04-23023 April 2024 Annual Report of Individual Monitoring for the Prairie Island Nuclear Generating Plant (PINGP) ML24113A1182024-04-12012 April 2024 NRC Letter Re NRC Office of Investigations Report No. 3-2023-004 ML24100A1212024-04-0909 April 2024 Submittal of Revised Pressure and Temperature Limits Report ML24093A2832024-04-0202 April 2024 Nuclear Material Transaction Report L-PI-24-012, Independent Spent Fuel Storage Installation - License Amendment Request: Revise Independent Spent Fuel Storage Installation (ISFSI) License Conditions 23(a), 24(A)(2), and 24(B)(2)2024-04-0202 April 2024 Independent Spent Fuel Storage Installation - License Amendment Request: Revise Independent Spent Fuel Storage Installation (ISFSI) License Conditions 23(a), 24(A)(2), and 24(B)(2) ML24089A2402024-03-29029 March 2024 Guarantee of Payment of Deferred Premiums ML24060A1232024-03-27027 March 2024 To Request 1-RR-5-10 and 2-RR-5-10 Regarding Reactor Pressure Vessel Welds and Nozzle Welds 05000282/LER-2023-001-01, Reactor Trip, Auxiliary Feedwater and Emergency Service Water System Actuation Due to Electrical Transient in DC Control Power Cables2024-03-21021 March 2024 Reactor Trip, Auxiliary Feedwater and Emergency Service Water System Actuation Due to Electrical Transient in DC Control Power Cables ML24262A1512024-03-15015 March 2024 L-PI-24-011 150 Day Letter 2024 PINGP ILT NRC Exam ML24010A0582024-03-0505 March 2024 Amendment No. 12 to Materials License No. Special Nuclear Material-2506 for the Prairie Island Independent Spent Fuel Storage Installation L-PI-24-004, Independent Spent Fuel Storage Installation - Annual Effluent Report, January Through December 20232024-02-29029 February 2024 Independent Spent Fuel Storage Installation - Annual Effluent Report, January Through December 2023 IR 05000282/20230062024-02-28028 February 2024 Annual Assessment Letter for Prairie Island Nuclear Generating Plant, Units 1 and 2 (Report 05000282/2023006 and 05000306/2023006) 2024-09-27
[Table view] Category:Safety Evaluation
MONTHYEARML24221A3622024-09-27027 September 2024 Issuance of Amendment Nos. 245 and 233 Revise Technical Specification 3.8.1, AC Sources-Operating, Surveillance Requirement 3.8.1.2, Note 3 ML24071A1162024-05-0101 May 2024 Issuance of Amendment Nos. 244 and 232 Revise TS 3.7.8, Cooling Water (Cl) System ML24100A8042024-04-24024 April 2024 – Alternative Request RR-09 for Safety Injection and Volume Control System Category C Check Valve Inservice Testing ML24060A1232024-03-27027 March 2024 To Request 1-RR-5-10 and 2-RR-5-10 Regarding Reactor Pressure Vessel Welds and Nozzle Welds ML23356A0032024-01-17017 January 2024 Issuance of Amendments Revise Technical Specification 5.6.6, Reactor Coolant System (RCS) Pressure and Temperature Limits Report (PTLR) ML23215A1672023-12-15015 December 2023 Acceptance of Requested Licensing Action Amendment Request to Revise Surveillance Requirement 3.8.1.2 Note 3 ML23115A4072023-04-26026 April 2023 Correction of License Amendment Nos. 226 and 214 Adoption of TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B ML22357A1002023-03-31031 March 2023 And Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendments Standard Emergency Plan and Consolidated Emergency Operations Facility ML22300A2232022-11-0101 November 2022 Issuance of Amendments 241 and 229 TSTF-577 Revised Frequencies for Steam Generator Tube Inspections ML22270A3252022-09-30030 September 2022 (Prairie Island), Unit 2 - Authorization and Safety Evaluation for Alternative Request No. RR-08 ML22181A0002022-08-17017 August 2022 Issuance of Amendments Reactor Trip System Power Range Instrumentation Channels ML22166A3892022-07-28028 July 2022 Issuance of Amendments 239 and 227 24-Month Operating Cycle ML22061A2062022-04-0101 April 2022 Issuance of Amendments TSTF-471, Rev. 1, TSTF-571-T, and Administrative Changes to Technical Specification Section 5.0 ML21312A0212021-11-23023 November 2021 Issuance of Amendment Nos. 237 and 225 Inoperable Cooling Water System Supply Header ML21008A0012021-03-19019 March 2021 Issuance of Amendment Nos. 236 and 224 Low Temperature Overpressure Protection ML20346A0202021-03-15015 March 2021 Issuance of Amendment Nos. 235 and 223, Adoption of Technical Specifications Task Force Traveler TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML20356A0022021-02-0505 February 2021 Issuance of Amendment Nos. 234 and 222, Revise Technical Specifications 3.2.1 and 5.6.5 Identified in Westinghouse Nuclear Safety Advisory Letters NSAL-09-05, Revision 1, and NSAL-15-1 ML20283A3422020-11-18018 November 2020 Issuance of Amendment Nos. 233 and 221 Adoption of Technical Specifications Task Force Traveler TSTF-547, Clarification of Rod Position Requirements ML20217L1852020-10-0202 October 2020 Issuance of Amendment Nos. 232 and 220 Increase the Integrated Leak Rate Test Program Type a and Type C Test Frequency ML20276A0032020-10-0202 October 2020 Request to Use a Provision of a Later Edition of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI ML20210M0142020-09-0808 September 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendment Nos. 204, 231, and 219 TSTF-529 Clarify Use and Application Rules ML20230A0512020-09-0303 September 2020 Reactor Vessel Material Surveillance Capsule Withdrawal Schedules ML20153A4012020-06-0101 June 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML20134H9582020-05-29029 May 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML20135G9922020-05-29029 May 2020 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME Code ML19276F6842019-11-12012 November 2019 Issuance of Amendments 230 and 218 Issuance of Amendments Adoption of 10 CFR 50.69 - Risk Informed Caterization and Treatment of Structure, Systems and Components of Nuclear Power Reactors ML19232A1512019-11-0707 November 2019 Issuance of Amendments Modifying the Design Basis for Quality Classification of Certain Fuel Handling Equipment ML19140A4472019-07-30030 July 2019 Issuance of Amendments Revision to National Fire Protection Association (NFPA) Standard NFPA 805 Modifications ML19177A3802019-07-0303 July 2019 Reactor Vessel Material Surveillance Capsule Withdrawal Schedules ML19128A1332019-06-0606 June 2019 Issuance of Amendments TSTF-439 Eliminate Second Completion Times Limiting Time from Discovery of Failure to Meet an LCO ML19045A4802019-04-16016 April 2019 Issuance of Amendment Nos. 226 and 214 Adoption of TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B ML19046A1662019-02-25025 February 2019 Relief from the Requirements of the ASME Code ML19029A0942019-01-29029 January 2019 Issuance of Amendment No. 213, One-Time Technical Specification Change to Extend Completion Time for EDGs D5 and D6 (Emergency Circumstances) ML18270A0152018-10-19019 October 2018 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Relief from the Requirements of the ASME OM Code ML18100A7882018-05-0101 May 2018 Issuance of Amendment Special Heavy Lifting Device Nondestructive Examination Frequency (CAC Nos. MG0072 and MG0073; EPID L-2017-LLA-0280) ML17346A3612018-03-0606 March 2018 Issuance of Amendment Nos. 224 and 211 to Adopt Changes to the Emergency Plan ML17362A2022018-03-0505 March 2018 Issuance of Amendment Concerning Revision to the Prairie Island Nuclear Generating Plant, Units 1 and 2 Emergency Plan (CAC Nos. MF9345 and MF9346; EPID L-2017-LLA-0175) ML17334A1782017-11-30030 November 2017 Issuance of Amendment Request Related to Spent Fuel Pool Criticality Technical Specification Changes (CAC Nos. MF7121 and MF7122, EPID L-2015-LLA-0002) Non-Proprietary ML17310B2392017-11-28028 November 2017 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendment Unit Staff Qualifications (CAC Nos. MF9545, MF9546, and MF9547; EPID L-2017-LLA-0195) ML17163A0272017-08-0808 August 2017 Issuance of Amendments Transition to NFPA-805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants ML17130A7162017-06-20020 June 2017 Issuance of Amendments Technical Specification 3.8.7 Inverters-Operating ML17110A2752017-05-0404 May 2017 Safety Evaluation Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders EA-12-049 and EA-12-051 ML16320A0212016-11-28028 November 2016 and Prairie Island Nuclear Generating Plant, Units 1 and 2 - Review of Changes to the Northern States Power Company Quality Assurance Topical Report ML16256A5142016-10-13013 October 2016 Issuance of Amendment One-Time Extension for Technical Specification Surveillance Requirement 3.8.4.3. DC Sources - Operating ML16246A2002016-10-0404 October 2016 Request for Relief 1RR-4-11 and 2-RR-4-11 Associated with Certain Inservice Inspection of Component Welds for the Fourth 10-Year Interval ML16133A4062016-06-16016 June 2016 Issuance of Amendment Nos. 217 and 205, Adoption of Technical Specifications Task Force TSTF-523, Revision 2, Generic Letter 2008-01, Managing Gas Accumulation (CAC Nos. MF6449 and MF6450) ML15264A2092015-11-30030 November 2015 Issuance of Amendment Nos. 216 and 204 Regarding Revisions to Technical Specification 3.3.3 and Renewed Facility Operating License ML15229A1762015-08-26026 August 2015 Issuance of Amendment Nos. 215 and 203 Regarding Revision to Licensing Basis Analysis for a Waste Gas Decay Tank Rupture ML15196A2132015-08-17017 August 2015 Requests 1-RR-4-9 and 2-RR-4-9 Associated with the Fourth Ten-Year Interval for the Inservice Inspection Program ML15196A2412015-08-12012 August 2015 Requests 1-RR-5-6 and 2-RR-5-6 Associated with the Fifth Ten-Year Interval for the Inservice Inspection Program 2024-09-27
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555*0001 August 31, 2009 Mr. Michael D. Wadley Site Vice President Prairie Island Nuclear Generating Plant Northern States Power - Minnesota 1717 Wakonade Drive East Welch, MN 55089
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 CORRECTION TO SAFETY EVALUATION SUPPORTING AMENDMENT NOS.
192 AND 181 RE: TECHNICAL SPECIFICATION CHANGES TO ALLOW USE OF WESTINGHOUSE 0.422-INCH OD 14 X 14 VANTAGE+ FUEL (TAC NOS.
MD9142 AND MD9143)
Dear Mr. Wadley:
On July 1, 2009, the Nuclear Regulatory Commission (NRC) issued Amendment No. 192 to Facility Operating License No. DPR-42 and Amendment No. 181 to Facility Operating License DPR-60 for the Prairie Island Nuclear Generating Plant, Units 1 and 2 (PINGP), respectively.
These amendments changed the PINGP Technical Specifications (TSs) to allow the use of Westinghouse 422 VANTAGE+ nuclear fuel and made changes to certain references identified in the Design Features section of the TSs.
Subsequent to the issuance, Mr. Len Sueper of your staff pointed out some errors in the safety evaluation (SE) supporting the amendments. We agree that editorial errors had been inadvertently made, resulting in some inaccurate statements in the SE. Enclosed please find the corrected pages 29, 30, and 51 of the SE, with side bars highlighting the areas of correction.
The NRC regrets any inconvenience that these editorial errors may have caused. If there are any questions regarding this matter, please contact me at 301-415-4037.
Sincerely,
'~l."~0'>-~~
Thomas J. we~ert, senior\Jroject Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-282 and 50-306
Enclosure:
As stated cc w/encls: Distribution via ListServ
- 29 2.4.2.2 LOCA Technical Evaluation The specific evaluations performed by the licensee address the acceptance criteria contained in 10 CFR 50.46(b)(1) through (b)(3), and (b)(5). By demonstrating compliance with these criteria, regarding PCT, local and core-wide oxidation, and long-term cooling capability, the licensee adequately demonstrates compliance with 10 CFR 50.46(b)(4), which requires that the core remain in a coolable geometry.
2.4.2.2.A Large Break LOCA By letter dated July 6, 2006, the licensee for PINGP Units 1 and 2 requested to implement new analytic methods to analyze large break LOCAs. Based on its detailed review of the licensee's (1) selection of analytic techniques, (2) implementation of analytic techniques, and (3) results of analysis, the NRC staff concluded that the licensee could use the referenced methods to analyze LOCAs and demonstrate compliance with the requirements of 10 CFR 50.46.
Reference 25 contains the staff's evaluation; the NRC staff summarizes in the following section the methods, their implementation, and the analytic results, which are based on the same method as described in Reference 25 but account for the fuel transition.
Large break LOCA analyses supporting the proposed fuel upgrade were performed by the licensee using the NRC-approved Automated Statistical Treatment of Uncertainty Method (ASTRUM) best-estimate large break LOCA (BE-LBLOCA) methodology (Reference 26). The licensee's method was approved by the NRC for implementation at PINGP Units 1 and 2 by Amendment 179 to the PINGP Unit 1 Facility Operating License, and Amendment 169 to the PINGP Unit 2 Facility Operating License. The NRC staff reviewed the fuel transition-related analytic results to confirm that they were acceptable.
The purpose of the licensee's analysis was to demonstrate conformance with the 10 CFR 50.46 requirements using the ASTRUM method. Important input assumptions, as well as analytical models and analysis methodology for the BE-LBLOCA were provided. Analysis results were also provided, which showed that no design or regulatory limit related to the BE-LBLOCA would be exceeded at the analyzed conditions.
The licensee provided results of the PINGP Units 1 and 2 BE-LBLOCA analysis in the LR, assuming that each plant is operating at 1,683 MWt, in accordance with the statistical best estimate approach. The licensee correctly assumed a loss of offsite power. The licensee evaluated transition core effects and concluded that the ASTRUM analysis for the 422V+ core at both units bounds both the 400V+ and transition cores. The results for calculated PCTs, the maximum local cladding oxidations, and the maximum core-wide cladding oxidations are repeated in the following table, based on the limiting results obtained in Unit 1:
Parameter PINGP Unit 1 Result 10 CFR 50.46 Limit Limiting Break Size/Location Split Break/Cold Leg N/A (Reference 36)
Cladding Material ZIRLO ' M (Cylindrical) Zircaloy or ZIRLO' Peak Cladding Temperature 1765°F 2200°F Maximum Local Oxidation 0.62-percent 17.0-percent Maximum Total Core-Wide 0.014-percent 1.OO-percent Oxidation Revised by letter dated August 31,2009
- 30 These results demonstrate acceptable compliance with 10 CFR 50.46(b)(1) through (b)(3). The results are discussed further in Reference 1.
The NRC staff reviewed the ASTRUM methodology, and confirmed that, in addition to the limiting split break, the method also considers slot breaks in the RCS cold leg. On this basis, the NRC staff finds the licensee's conclusion that the PINGP Units 1 and 2 PCT-Iimiting transient is a split break acceptable, because uncertainties related to break type and size were included in the modeling approach.
The licensee evaluated the possibility of a return to criticality during the reflood stage of the LOCA and confirmed that an increase in the TS minimum boric acid concentration in the ECCS equipment would be needed. This change is acceptable with respect to the BE-LBLOCA evaluation because the increase is explicitly calculated and shown to prevent a return to criticality. This change is also evaluated for the potential for boric acid precipitation in Section 2.4.2.2.0 of this SE, and the TS change request is evaluated in Section 3.2 of this SE.
Based on its review of the licensee's application of the ASTRUM BE-LBLOCA methodology, the NRC staff concluded that the Westinghouse BE LBLOCA methodology is acceptable for use for PINGP Units 1 and 2 in demonstrating compliance with the requirements of 10 CFR 50.46(b)(1) through (b)(3), operating with the requested fuel upgrade. The NRC staff's conclusion was based on the fact that the PINGP Units 1 and 2 analyses were conducted within the conditions and limitations, and supporting technical basis, of the NRC-approved Westinghouse BE LBLOCA methodology.
2.4.2.2.B Small Break LOCA The small break LOCA (SBLOCA) includes all postulated pipe ruptures with a total cross sectional area less than 1.0 square foot. The SBLOCAs analyzed are for those breaks beyond the capability of a single charging pump, resulting in the actuation of the ECCS. The analysis was performed to demonstrate conformance with the 10 CFR 50.46 requirements for the fuel upgrade conditions associated with PINGP, Units 1 and 2.
The licensee analyzed small break LOCAs using the NOTRUMP-EM as described in WCAP 10054-P-A, WCAP-10054-P-A, Addendum 2, and WCAP-10079-P-A (Reference 27). In consideration of the proposed fuel transition, the NRC staff reviewed the results to confirm that the licensee complies with the 10 CFR 50.46 requirements.
The licensee considered a spectrum of cold-leg break sizes that included equivalent diameters of 1.5, 2, 3, 4, 6, and 8 inches and an accumulator line break of 10.126 inches. At Unit 1, the 3-inch break was limiting with a PCT of 959°F, and at Unit 2, the 2-inch break was limiting with a PCT of 965°F. Intermediate break sizes were not considered because the evaluated spectrum demonstrated significant margin to the 2200°F limit set forth by 10 CFR 50.46. The licensee's results indicated that, for the 1.5, 6, 8, and 10.126-inch breaks, core uncovery was not expected at either unit.
The licensee acknowledged an NRC concern that top-oriented breaks could lead to longer term core uncovery due to the potential for RCP loop seal plugging. The licensee stated that such a scenario is very unlikely because it relies on a very delicate set of conditions. The licensee indicated that a more likely scenario would be core mixture level oscillations associated with the loop seals plugging with water and subsequently clearing due to the buildup of steam pressure Revised by letter dated August 31,2009
- 51 Use of Westinghouse 0.422-inch OD 14x14 VANTAGE+ Fuel (TAC Nos. MD9142 and MD9143) - Letter to U. S. Nuclear Regulatory Commission, May 4, 2009 (ADAMS Accession No. ML091310384).
- 36. Dederer, S.1. et aI., Westinghouse Electric Company, LLC, "Application of Best Estimate Large Break LOCA Methodology to Westinghouse PWRs With Upper Plenum Injection,"
WCAP-14449-P-A, Revision 1, October 1999.
Principal Contributors:
B. Parks, NRRlDSS/SRXB S. Wu, NRRlDSS/SNPB B. Lee, NRRlDSS/SCVB C. Schulten, NRRlDIRS/ITSB C. Basavaraju, NRRlDE/EMCB Date: July 1, 2009 Revised by letter dated August 31, 2009
August 31, 2009 Mr. Michael D. Wadley Site Vice President Prairie Island Nuclear Generating Plant Northern States Power - Minnesota 1717 Wakonade Drive East Welch, MN 55089
SUBJECT:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 CORRECTION TO SAFETY EVALUATION SUPPORTING AMENDMENT NOS.
192 AND 181 RE: TECHNICAL SPECIFICATION CHANGES TO ALLOW USE OF WESTINGHOUSE 0.422-INCH OD 14 X 14 VANTAGE+ FUEL (TAC NOS.
MD9142 AND MD9143)
Dear Mr. Wadley:
On July 1, 2009, the Nuclear Regulatory Commission (NRC) issued Amendment No. 192 to Facility Operating License No. DPR-42 and Amendment No. 181 to Facility Operating License DPR-60 for the Prairie Island Nuclear Generating Plant, Units 1 and 2 (PINGP), respectively.
These amendments changed the PINGP Technical Specifications (TSs) to allow the use of Westinghouse 422 VANTAGE+ nuclear fuel and made changes to certain references identified in the Design Features section of the TSs.
Subsequent to the issuance, Mr. Len Sueper of your staff pointed out some errors in the safety evaluation (SE) supporting the amendments. We agree that editorial errors had been inadvertently made, resulting in some inaccurate statements in the SE. Enclosed please find the corrected pages 29, 30, and 51 of the SE, with side bars highlighting the areas of correction.
The NRC regrets any inconvenience that these editorial errors may have caused. If there are any questions regarding this matter, please contact me at 301-415-4037.
Sincerely, IRAJ Thomas J. Wengert, Senior Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-282 and 50-306
Enclosure:
As stated cc w/encls: Distribution via ListServ DISTRIBUTION:
PUBLIC LPL3-1 r/f RidsRgn3MailCenter Resource RidsNrrDssSrxb Resource RidsNrrPMPrairielsland Resource RidsNrrDorlLpl3-1 Resource RidsNrrDorlDpr Resource RidsAcrsAcnw_MailCTR Resource RidsNrrLABTully Resource RidsOgcRp Resource BParks, NRR ADAMS Accession Number' ML092240332 OFFICE NRR/LPL3-1/PM NRR/LPL3-1/LA NRRlDSS/SRXB/BC NRR/LPL3-1/BC NAME TWengert BTully ITHarris for GCranston LJames DATE 08/13/09 08/13/09 08/19/09 08/31/09 OFFICIAL RECORD COpy