December 23, 2005 Mr. James A. Spina Vice President Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2, AMENDED LICENSE RENEWAL APPLICATION (TAC NOS. MC3272 AND MC3273)

Dear Mr. Spina:

By letter dated July 14, 2005, Constellation Energy Group, Inc. (CEG), resubmitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 (10 CFR Part 54), to renew the operating licenses for the Nine Mile Point Nuclear Station (NMP), Units 1 and 2, for review by the U.S. Nuclear Regulatory Commission (NRC). The NRC staff is reviewing the information contained in the amended license renewal application (ALRA) and has identified, in the enclosure, areas where additional information is needed to complete the review.

The staff requests that you provide your response within 20 days from the date of this letter. If you have any questions regarding this letter or if circumstances result in your need to revise the response date, please contact me by telephone at 301-415-1458 or via e-mail at nbl@nrc.gov.

Sincerely,

/RA/

N. B. (Tommy) Le, Senior Project Manager License Renewal Branch B Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-220 and 50-410

Enclosure:

As stated cc w/encl: See next page

ML053570337 DISTRIBUTION:

See next page Document Name: E:\\Filenet\\ML053570337.wpd OFFICE RLRB:PM DLR:LA RLRB (A):BC NAME N. Le MJenkins L. Lund DATE 12/ 22 /05 12/ 22 /05 12/ 23 /05

Letter to James A. Spina from Ngoc Le dated _December 23, 2005

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2, AMENDED LICENSE RENEWAL APPLICATION (TAC NOS. MC3272 AND MC3273)

DISTRIBUTION:

PUBLIC SSmith (srs3)

RidsNrrDrip RidsNrrDe RidsNrrDss RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDci RidsNrrDnrl RidsNrrDeEeeb RidsNrrDeEqva RidsNrrDeEqvb RidsNrrDeEemb RidsOgcMailCenter RidsNrrDssSbpb RidsResDetErab RidsAcrsAcnwMailCenter DLR R/F CHolden RLaufer PTam BFuller, RI EKnutson, RI JTrapp, RI TKoshy PYChen HAshar DJeng JBurns MLemoncelli OPA

NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2 (NMP1 AND NMP2)

AMENDED LICENSE RENEWAL APPLICATION (ALRA)

REQUEST FOR ADDITIONAL INFORMATION (RAI) - BATCH 6 REACTOR PRESSURE VESSEL (RPV) BIOLOGICAL SHIELD - NMP UNIT 2 ONLY) aRAI 4.7.1B-1 With respect to time-limited aging analysis (TLAA) 4.7.1 on the RPV Biological Shield, for NMP2, please provide a calculation using an NRC-approved fluence methodology that will not invalidate your original fracture mechanics analysis (i.e., fluence will be less than 1E17 n/cm2).

The methodology that is referred to in the amended LRA, has not been reviewed and approved by the staff. Otherwise, the applicant could submit a commitment indicating that the calculation/methodology will be submitted to the staff for review and approval 2 years prior to the period of extended operation.

TABLE 3.4.1-A AGING MANAGEMENT PROGRAM FOR STEAM AND POWER CONVERSION SYSTEMS aRAI 3.4.1.A-1 In the NMP ALRA Table 3.4.1.A Items 3.4.1.A-09, and 3.4.1.A-10, the applicant states that these items are not applicable because ?All other heat exchangers are of a different material (copper alloys or stainless steel) and do not have this aging effect/mechanism. However, both copper alloy and stainless steel are subjected to the aging effects of pitting and crevice corrosion. Please explain the discrepancy provided under the discussion columns of the table.

Enclosure

Nine Mile Point Nuclear Station, Units 1 and 2 cc:

Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 126 Lycoming, NY 13093 Supervisor Town of Scriba Route 8, Box 382 Oswego, NY 13126 Mr. James R. Evans LIPA P.O. Box 129 Lycoming, NY 10393 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Paul D. Eddy Electric Division NYS Department of Public Service Agency Building 3 Empire State Plaza Albany, NY 12223 C. Adrienne Rhodes Chairman and Executive Director State Consumer Protection Board 5 Empire State Plaza, Suite 2101 Albany, NY 12223-1556 Kathryn M. Sutton, Esquire Morgan, Lewis & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street, NW Washington, DC 20005-3502 Mr. Michael J. Wallace President Nine Mile Point Nuclear Station, LLC c/o Constellation Energy Group, Inc.

750 East Pratt Street Baltimore, MD 21202 Carey W. Fleming, Esquire Sr. Counsel - Nuclear Generation Constellation Generation Group, LLC 750 E. Pratt Street, 17th Floor Baltimore, MD 21202 Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. James Ross Nuclear Energy Institute 1776 I St., NW, Suite 400 Washington, DC 20006-3708 Mr. Mark Flaherty Manager - Fleet Licensing R. E. Ginna Nuclear Power Plant 1503 Lake Road Ontario, NY 14519 Mr. M. Steven Leonard General Supervisor - Nuclear Regulatory Matters Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093

Nine Mile Point Nuclear Station, Units 1 and 2 cc:

Mr. Peter Mazzaferro Site Project Manager - License Renewal Nine Mile Point Nuclear Station, LLC P.O. Box 63 Lycoming, NY 13093 Mr. Mike Heffley Senior Vice President and Chief Nuclear Officer Constellation Generation Group 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401