Category:Environmental Monitoring Report
MONTHYEARML24032A0202024-01-31031 January 2024 NPDES Biocide/Corrosion Treatment Plan Annual Report, Cy 2023 ML24011A3172024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), September 2023 ML24011A3202024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), December 2023 ML24011A3182024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), October 2023 ML24011A3192024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), November 2023 ML24011A3162024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), August 2023 ML23346A1222023-12-12012 December 2023 Annual Non-Radiological Environmental Operating Report - 2023 ML23275A0272023-09-29029 September 2023 Submittal of Discharge Monitoring Report (DMR) Quality Assurance Study 43 Final Report 2023 ML23233A0142023-08-15015 August 2023 Discharge Monitoring Report (Dmr), July 2023 ML23200A0202023-07-13013 July 2023 Discharge Monitoring Report (Dmr), June 2023 ML23165A2852023-06-14014 June 2023 Discharge Monitoring Report (Dmr), May 2023 ML23165A2862023-06-14014 June 2023 Tennessee Multi-Sector Permit (Tmsp), 2023 Annual Discharge Monitoring Report for Outfalls SW-1, SW-16, SW-17, SW-18, SW-19, and SW-21 ML23163A0382023-06-0808 June 2023 Discharge Monitoring Report (Dmr), April 2023 ML23121A0182023-04-27027 April 2023 Discharge Monitoring Report (Dmr), March 2023 ML23121A0232023-04-27027 April 2023 Tennessee Multi-Sector Permit (Tmsp), 2023 Annual Discharge Monitoring Report for Outfalls SW-2, SW-3, SW-4, SW-6, SW-8, SW-9, and SW-13 ML23075A1932023-03-16016 March 2023 Discharge Monitoring Report (Dmr), February 2023 ML23046A3552023-02-15015 February 2023 Annual Water Withdrawal Report 2022 ML23046A3482023-02-15015 February 2023 Discharge Monitoring Report (Dmr), January 2023 ML23019A3442023-01-19019 January 2023 Tennessee Multi-Sector Permit (Tmsp), 2022 Annual Discharge Monitoring Report for Outfalls SW-1, SW-16, and SW-19 ML23017A0212023-01-12012 January 2023 Discharge Monitoring Report (Dmr), December 2022 ML23017A0162023-01-12012 January 2023 Discharge Monitoring Report (Dmr), September 2022 ML23017A0182023-01-12012 January 2023 Discharge Monitoring Report (Dmr), October 2022 ML23017A0202023-01-0505 January 2023 Discharge Monitoring Report (Dmr), November 2022 ML23003A0262022-12-21021 December 2022 Tennessee Multi-Sector Permit (Tmsp), 2022 Annual Discharge Monitoring Report for Outfalls SW-17, SW-19, and SW-21 ML22347A0812022-12-13013 December 2022 Annual Non-Radiological Environmental Operating Report 2022 ML22255A0252022-09-12012 September 2022 Submittal of Discharge Monitoring Report (Dmr), August 2022 ML22251A1192022-09-0808 September 2022 Discharge Monitoring Report (DMR) Quality Assurance Study 42 Final Report 2022 ML22195A2362022-07-14014 July 2022 June 2022 Discharge Monitoring Report ML22166A3572022-06-15015 June 2022 May 2022 Discharge Monitoring Report (DMR) ML22137A2672022-05-17017 May 2022 Discharge Monitoring Report (Dmr), April 2022 ML22132A1912022-05-12012 May 2022 Submittal of Discharge Monitoring Report (Dmr), March 2022 ML22132A1842022-05-12012 May 2022 Submittal of Discharge Monitoring Report (Dmr), February 2022 ML22132A1762022-05-12012 May 2022 Tennessee Multi-Sector Permit (Tmsp), 2021 Annual Discharge Monitoring Report for Outfalls SW-2, SW-3, SW-4, SW-6, SW-8, SW-9, and SW-13 ML22131A1342022-05-11011 May 2022 Annual Radiological Environmental Operating Report for 2021 ML22115A1782022-04-25025 April 2022 Annual Radioactive Effluent Release Report for 2021 Monitoring Period ML22045A0222022-02-11011 February 2022 Discharge Monitoring Report (Dmr), January 2022 ML22018A0422022-01-13013 January 2022 Discharge Monitoring Report (Dmr), December 2021 ML22018A0342022-01-13013 January 2022 Tennessee Multi-Sector Permit (Tmsp), 2021 Annual Discharge Monitoring Report for Outfalls SW-1, SW-16, SW-17, SW-18, and SW-21 ML21348A3372021-12-14014 December 2021 Annual Non-Radiological Environmental Operating Report - 2021 ML21348A7152021-12-14014 December 2021 Discharge Monitoring Report (Dmr), November 2021 ML21347A9022021-12-13013 December 2021 Discharge Monitoring Report (DMR) Quality Assurance Study 41 Follow-up Report 2021 ML21320A0152021-11-15015 November 2021 Discharge Monitoring Report (DMR) Quality Assurance Study 41 Final Report 2021 ML21320A0192021-11-15015 November 2021 Discharge Monitoring Report (Dmr), September 2021 ML21320A0242021-11-15015 November 2021 Discharge Monitoring Report (Dmr), October 2021 ML21259A1582021-09-16016 September 2021 Discharge Monitoring Report (Dmr), August 2021 ML21250A0082021-09-0303 September 2021 Tennessee Multi-Sector Permit (Tmsp), 2021 Annual Discharge Monitoring Report for Outfalls SW-3 and SW-6 ML21242A0172021-08-24024 August 2021 Discharge Monitoring Report (Dmr), July 2021 ML21202A0642021-07-20020 July 2021 Discharge Monitoring Report (Dmr), June 2021 ML21167A0142021-06-15015 June 2021 Discharge Monitoring Report (Dmr), May 2021 ML21137A0172021-05-14014 May 2021 Plan, Submittal of Discharge Monitoring Report, April 2021 2024-01-31
[Table view] Category:Letter
MONTHYEARML24032A0202024-01-31031 January 2024 NPDES Biocide/Corrosion Treatment Plan Annual Report, Cy 2023 ML23319A2452024-01-29029 January 2024 Issuance of Amendment Nos. 366 and 360; 164 and 71 Regarding the Adoption of TSTF-567, Revision 1, Add Containment Sump TS to Address GSI-191 Issues CNL-24-017, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure and Emergency Preparedness Department Procedure Revisions2024-01-17017 January 2024 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure and Emergency Preparedness Department Procedure Revisions ML24018A0142024-01-17017 January 2024 Engine Systems, Inc., Report No. 10CFR21-0137, Rev. 1, 56913-EN 56913 ML24011A3182024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), October 2023 ML24011A3172024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), September 2023 ML24011A3202024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), December 2023 ML24011A3162024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), August 2023 ML24011A3192024-01-11011 January 2024 Submittal of Discharge Monitoring Report (Dmr), November 2023 IR 05000327/20234422024-01-11011 January 2024 95001 Supplemental Inspection Report 05000327/2023442 and 05000328/2023442 and Follow-Up Assessment Letter ML24010A2132024-01-10010 January 2024 CFR 21.21 Final Report Regarding Siemens Medium Voltage Circuit Breakers ML24018A0952024-01-0404 January 2024 Engine Systems, Inc., 10CFR21 Reporting of Defects and Non-Compliance Report No. 10CFR21-0137, Rev. 0 ML24004A0332024-01-0303 January 2024 Interim Report of a Deviation or Failure to Comply Crompton Instruments Type 077 Ammeter ML24004A0402024-01-0303 January 2024 Response to NRCs November 8, 2023, Request for Additional Information - Related to Independent Spent Fuel Storage Installation CNL-23-068, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-12-21021 December 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation CNL-23-036, Application to Revise Function 5 of Technical Specification Table 3.3.2-1, Engineered Safety Feature Actuation System Instrumentation, for the Sequoyah Nuclear Plant and Watts Bar Nuclear Plant (SQN-TS-23-02 and WBN-TS-23-08)2023-12-18018 December 2023 Application to Revise Function 5 of Technical Specification Table 3.3.2-1, Engineered Safety Feature Actuation System Instrumentation, for the Sequoyah Nuclear Plant and Watts Bar Nuclear Plant (SQN-TS-23-02 and WBN-TS-23-08) ML23346A1222023-12-12012 December 2023 Annual Non-Radiological Environmental Operating Report - 2023 IR 05000327/20234202023-11-28028 November 2023 Security Baseline Inspection Report 05000327/2023420 and 05000328/2023420 CNL-23-067, Central Emergency Control Center Emergency Plan Implementing Procedure Revisions2023-11-27027 November 2023 Central Emergency Control Center Emergency Plan Implementing Procedure Revisions ML23324A4362023-11-0909 November 2023 Exam Corporate Notification Letter Aka 210-day Letter ML23307A0822023-11-0808 November 2023 Request for Additional Information August 4, 2022, Exemption Request for Deviating from the Conditions of Certificate of Compliance No. 1032, Amendment No. 3, Related to Sequoyah Nuclear Plant Independent Spent Fuel Storage Installation IR 05000327/20230032023-11-0303 November 2023 Integrated Inspection Report 05000327/2023003 and 05000328/2023003 ML23306A1592023-11-0202 November 2023 Enforcement Action EA-22-129 Inspection Readiness Notification ML23292A0792023-10-19019 October 2023 Tennessee Valley Authority - Emergency Plan Implementing Procedure Revision, Includes EPIP-5, Revision 58, General Emergency IR 05000327/20230112023-10-16016 October 2023 Triennial Fire Protection Inspection Report 05000327/2023011 and 05000328/2023011 ML23285A0882023-10-12012 October 2023 Submittal of Sequoyah Nuclear Plant, Units 1 and 2, Submittal of Updated Final Safety Analysis Report Amendment 31 ML23284A4252023-10-11011 October 2023 10 CFR 50.59 and 10 CFR 72.48 Changes, Tests, and Experiments Summary Report; Commitment Summary Report; and Update to the Fire Protection Report ML23283A2792023-10-10010 October 2023 Revisions to the Sequoyah Nuclear Plant Units 1 and 2 Technical Requirements Manual ML23279A0612023-10-0505 October 2023 Paragon Energy Solutions LLC, Part 21 Final Report Re Potential Defect with Eaton Jd and Hjd Series Molded Case Circuit Breakers (Mccbs) ML23277A0462023-10-0404 October 2023 Revisions to the Sequoyah Nuclear Plant Units 1 and 2 Technical Specification Bases ML23275A0272023-09-29029 September 2023 Submittal of Discharge Monitoring Report (DMR) Quality Assurance Study 43 Final Report 2023 ML23271A1662023-09-28028 September 2023 Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(b)(2) CNL-23-059, Supplement to Sequoyah Nuclear Plant, Units 1 and 2, and Watts Bar Nuclear Plant, Units 1 and 2, Application to Revise Technical Specifications to Adopt TSTF-567-A, Revision 1, Add Containment Sump TS to Address GSI-191 Issues (SQN-TS-23-2023-09-20020 September 2023 Supplement to Sequoyah Nuclear Plant, Units 1 and 2, and Watts Bar Nuclear Plant, Units 1 and 2, Application to Revise Technical Specifications to Adopt TSTF-567-A, Revision 1, Add Containment Sump TS to Address GSI-191 Issues (SQN-TS-23-03 CNL-23-061, Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revision2023-09-20020 September 2023 Tennessee Valley Authority - Central Emergency Control Center Emergency Plan Implementing Procedure Revision IR 05000327/20234032023-09-14014 September 2023 Cyber Security Inspection Report 05000327/2023403 and 05000328/2023403 (Cover Letter) ML23257A0062023-09-14014 September 2023 Enforcement Action EA-22-129 Inspection Postponement Request ML23254A2192023-09-11011 September 2023 Emergency Plan Implementing Procedure Revisions ML23254A0652023-09-0707 September 2023 Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(b)(2) CNL-23-057, Central Emergency Control Center Emergency Plan Implementing Procedure Revisions. Includes CECC-EPIP-1, Revision 76 and CECC-EPIP-9, Revision 642023-09-0505 September 2023 Central Emergency Control Center Emergency Plan Implementing Procedure Revisions. Includes CECC-EPIP-1, Revision 76 and CECC-EPIP-9, Revision 64 IR 05000327/20230052023-08-29029 August 2023 Updated Inspection Plan for Sequoyah Nuclear Plant, Units 1 and 2 - Report 05000327/2023005 and 05000328/2023005 ML23233A0122023-08-17017 August 2023 Unit 1 Cycle 25 Refueling Outage - 90-Day Inservice Inspection Summary Report - Supplement ML23233A0142023-08-15015 August 2023 Discharge Monitoring Report (Dmr), July 2023 ML23215A1212023-08-0303 August 2023 301 Exam Administrative Items (2B) Normal Release ML23215A1572023-08-0303 August 2023 Enforcement Action EA-22-129 Inspection Readiness Notification CNL-23-028, Application to Revise Technical Specifications to Adopt TSTF-567-A, Revision 1, Add Containment Sump TS to Address GSI-191 Issues (SQN-TS-23-03 and WBN-TS-23-06)2023-08-0202 August 2023 Application to Revise Technical Specifications to Adopt TSTF-567-A, Revision 1, Add Containment Sump TS to Address GSI-191 Issues (SQN-TS-23-03 and WBN-TS-23-06) ML23192A4472023-07-31031 July 2023 Staff Assessment of Updated Seismic Hazards at TVA Sites Following the NRC Process for the Ongoing Assessment of Natural Hazards Information 2024-01-04
[Table view] |
Text
Tennessee Valley Authority, Post Office Box 2000, Sodd:y-Daisy, Tennessee 37379-2000 I L . I November 15, 2002 State of Tennessee
_D~ m-ti-ient 6f En~viro:fnment and-Conservationr Division of Water Pollution Control Enforcement & Compliance Section 6 h Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534 Attention: Ms. Evelyn Haskin
Dear Ms. Haskin:
TENIESSEE VALLEY AUTHORITY - SEQUOYAH NUCLEAR PLANT (SQN)
AMENDED DISCHARGE MONITORING REPORT (DMR) FOR AUGUST 2002 The following describes a revision to the SQN DMR for August 2002:
During the period of August 9 through September 5, a flow measurement error occurred at Chickamauga Hydro. This, in turn, created small errors in the computed NPDES compliance parameters for water temperature. The parameters were corrected before submittal of the September DMR, but the corrections were not completed in time for submittal of the August DMR.
Please find enclosed the corrected DMR for August 2002 which reflects the change for parameter Temperature, Water Degrees Centigrade Effluent Gross Value from the reported value of 43.7 degrees Celsius Daily Maximum to 43.6 degrees Celsius Daily Maximum and for parameter Temperature Difference Between Sample and Upstream Degrees Centigrade Effluent Gross Value from the reported value of 2.1 degrees Celsius to 2.2 degrees Celsius.
Pmted on necy-Xed papr
Ms. Evelyn Haskin Page 2 November 15, 2002 These value changes did not result in any exceedance of permit limits. If you have any questions, please contact Richard D. Nunley at (423) 843-7748.
iCerel D. Osborne cting Environmental Supervisor Signatory Authority for Richard T. Purcell Site Vice President Sequoyah Nuclear Plant Enclosure cc (Enclosure):
Chattanooga Environmental Assistance Center Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue ChattanoogajTennessee 37402-2013 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555
PERMITTEE NAME/AD DRESS (Include FacilityName/Loca lon /f Different) NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) MAJOR Form Approved.
hpLame_ TVA - SEQUOYAH NUCLEAR PLANT DISCHARGE MONITORING REPORT (DMRU 004 (SUBR 01) OMB No. 2040-00
-JNERHaMA ...
_--*_ -__-*--y-DAM s.s-. .. .:E*. .j
._ . T6N00 26450 101 FINAL PERMIT NUMBER I DISCHARGE NUMiE DIFFUSER DISCHARGE Foc,_lty.__IVA -__SQUQY.I-J--------T PERIO 1:1EFFLUENT Locatlon HAMILTO N.CO-CQ.UNfry - ---- YFAp I M Q MONITRING IA IvYE:A RI M n I I A YODSC A G f~l ram~j To'* NO DISCHARGEr- .° ATTN Jerry D. Osborne I J F "rom 0nI0n To 1en2 f NOTE- Read R2oa instructions before completing this s form form PARAMETER ' QUANTITY OR LOADING QUALITY OR CONCENTRATION NO. FREQUENCY SAMPLE
_ _ EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE I MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG. SAMPLE ** 30.5 (04) 0 31 / 31 MODELD CENTIGRADE MEASUREMENT 00010 Z 0 0 ~ ~A
~ ....... ~ 35DEG. C. . .:::-~CK(R INSTREAM MONITORING :....
ii..~iii l~i; ii
.. .. . ::z
~ ~ '~
. .. ~PR( ..
TEMPERATURE, WATER DEG. SAMPLE 43.6 (04) 0 31 / 31 RCORDR CENTIGRADE MEASUREMENT 00010 1 0 0 . .PE M .. :" *, m:::: ****4**' . , ........ :R: DEG.......
SS VALUE EFFLUENT.GRO M.N: ..: . .:. ....... .. DE. .........................................
EFFLUENT GOSVLE....... ... EMT..
PH SAMPLE 7.4 8.0 (12) 0 8/31 GRAB MEASUREMENT 00400 1 0 0 P!R i::S.U: £ : : sU .... W*EE(L: 1!R*B EFFLUENT GROSS VALUE .. . ....
SOLIDS, TOTAL SUSPENDED SAMPLE *5 5 0 4 / 31 GRAB MEASUREMENT (19)
OIL AND GREASE SAMPLE ****** ........... ********** .... f -:::::::..:..::..:::
+ ,:. :..:: .:...::.. :. <5
- : :::: : ::::::::, <5 :: : :: : 19 0 4 /31 GRAB MEASUREMENT *(9 00556 1 0 0 !ii:::!:iiiPEIRMfl..:::::!:: * *::i:****:*i*~~*iii* iiiiii... **
55::i~i:!i
- iiii! iiiii~ii: iii!:!*.:ii::i "i*.;!!~i '.20* i MG/L ::!:: W EEKLY G;;RAB. r EFFLUENT GROSS VALUE R*UIR*;i.~i**::MENT
~~~~i~ii.*i'i.*~ii!*i.ii~!ii ii:.*;.
AX....:.............. iiii~:;i"A:X
........... .~.....
O !;VP ii!:::: A~y i
?:iii:,iiiiiiiiii!!.iiiiiiiiiiiiiiiiiiiiliiiiiiiiii~iii
_______ _______i::i:;
FLOW, IN CONDUIT OR THRU SAMPLE *1709 (03) *. 0 31/.31 RCORR E F F L E NTU RPLANT TREATMENT OSTV A LEO. U.. MEASUREMENT iiii~iiiill~
.... ....i:~ ii:ii~iilll~
.... ..:i:;
50050 1 0 0 :i PE:iiRMl'IT:**:i~~~ *iiiiii. . . ~ ...
. ... :iii:ii*iiiRE
.. . . *O RT :* MGD * *AAi::ii.:. :iiiie* Aeiii~~~~.: .. iii~!!~:I .ICO iNT ; RCQRi*D R.
- .:i................
'***::::iii!:*ii.. '*~;,****iiii J;..........
CHLORINE, TOTAL RESIDUAL . TYPEDORPINTE*****
SAMPLE * ************* OFICE<0.010 OR UTHOIZEDA'*'* 0.020 "W"' (1) 0 36 /31 OGRAB A...
MEASUREMENT OIL ANCRASOAPED51 *(9 <, 1) 0 4/1 GA 50060 1 0 0O ::~i R:*
Miti.::ii::i~~i*l :iii:i EFFLUEN GRO
- iiiii; %:. ::..*i:i:iiiiiii*:iiii.
S.VLUE......... .. : ~iiiii:: .... '!~~!:::..
...... ......i**ii!!o :0
- iiii.o:iii~i ii0.058'i~iiiiiii MGIL :" E:EK-
- i:iii::::il.W :: iii:,iCAV*TP NAME/TITLE PRINCIPAL EXECUTIVE OFFICER ICertify under penalty of law that this document and all attachimenta were prepared under my F,** , _j., 'ELEPHONE T.( DATE lirection or supeivisin In accordance with a system deslgned to assure that qtatified - " It" Richard T. Purcell personnel properly gather and evaluate the information submitted Based on my inquiry of the/
person or persons who manage the system, or those persons directly responsible for gatheri9 StViePeietthe information, the information submitted :s to the best of my knowledge and betief, tre nvromntlS eio 423 843-7630 02 11 13 StVcePeietaccurate, and complete l am aware that teeare significant penalties for submitting false \ SIGNATURE OF PRINCIPAL EXECUJTIVE ....................i TYE RPRNE formation, including the possibility of fine and lmpnsonment for knowing violations OFIEIRATOIE GN RAM A COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all atfachments here No closed mode operation. The following Injections occured: 1. PCL-222 (max. calc. conc. was 0 055mg/L-ltmit 0 1 00mg/L) 2. CL-363 (max. talc. conc was 0 009mg/L-limit 0 100mg/L) 3. PCL-222/PCL-401 (max. calc. cono. was 0 019mg/L-Iimit 0.100mg/L) 4. H-130M (max. dalc conc. was 0 025mg/L-limlt 0.050mg/L) I EPA Form 3320-1 (REV 3/99) Previouseditions may be used I Page I of 2
PERMITTEE NAME/AD DRESS (Include FacilityNamelocatlon ff Dilfferent) NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDESJ Form Approved.
MAJOR
.V[.meý _TVA - SEQUOYAH NUCLEAR PLANT Addref_ I_39_E= -. - - --------- - 1 DISCHARGE MONITORING REPORT (DMRJ PERMIT NUMBER ID ISCHARGENUMBE (SUBR 01)
F " FINAL OMB No 2040-001 04 DIFFUSER DISCHARGE Q jt__( -1AT _ýFF UFC
-[.-----....
jLEAR.
EFFLUENT MO FrNITmPINC LoqatLon HAMILTON COUNY YFAIP PFRIOQ r)AY I YEAR I. IA DAY From 02 108 101 IT0102 108 131 NO DISCHARGE I ATrN. Jerry D. Osborne PARAMETER t PARAMETER________EX AVERAGE QUANTITY OR LOADING MAXIMUM UNITS MINIMUM QUAUTY OR CONCENTRATION AVERAGE NOTE: Read instructlions before completing this form.
MAXIMUM UNITS NO. FREQUENCY OF ANALYSIS SAMPLE TYPE TEMPERATURE - C, RATE OF SAMPLE 0.4 (*0
( 31 /31 CAL*T*
CHANGE MEASUREMENT EFFLUENT GROSS VALUE .. ~ ~ :..:.ii..:.!.. ."..
TEMP. DIFF. BETWEEN SAMP. & SAMPLE 2.2*.**,...******..,*.**********
(04) 0 31 / 31 CALCTD UPSTRM DEG.C MEASUREMENT EFFLUENT GROSS VALUE . . .................. .i ... iiii:. .... V U ......
SAMPLE 4 MEASUREMENT RRE U MEN ... .. ... . .xX SAMPLE MEASUREMENT I
... I........................................................... ....................... . . . ...... . ..... ..
BORON, TOTAL SAMPLE ****
- .i:ii...i*H
- <0.2 .... .:::iiii i::::i <0.2
..................... <0.2 (19) 0 1/31 GRAB ... x:
o~o* ,
- 1. 0o 0....EP0RT o ..022
MEASUREMENT *`````````* REPo.EPORT MG/L ONCEI GRAB FFLUENT GROS.S VALU.E MEASUREMENT SAMPLE MEASUREMENT direction Or supervision In accordance with a system designed to assure that qualified Richard T. Purcell person.or personnel persons properly who gathermanage the system, and evaluste or those persons the information directly submitted responsible Based for gah.er.ng(
on my inquiryof the Peietthe Information, the Information submitted ae,to the best of my knowledge and belief, true, *, E' ronmental Supervisor 423 843-7630 02 11 13 Site Vilce Peintaccurate, and complete l an aware that there are significant penalties for submitting false *' NATURE OF PRINCIPAL EXECUTIVE TYPED OR PRINTED OFIEORATOIEAGN ARA NMR YAR eDA COMMENTS AND EXPLANATION OF ANY 'VIOLATIONS CCW data for August 2002 Is attached.
(R~eferernce all attachments here E om..V.ri e tn y e e.. I, EPA Form 3320-1 (REV 3/99) Previouseditions may be used Page 2 of 2