ATTACHMENT 2 Table A - Administrative Changes Matrix

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 1.0 - USE AND APPLICATION DOC #

SUMMARY

ITS SECTION CTS SECTION Al Editorial changes, reformatting, and revised numbering.

1.0 1.0, 4.1.A footnote

  • 4.2.A footnote
  • RETS 1.0 A2 The CTS introductory note, which discusses the reasons for the Definitions, is replaced with a more specific "Note" in ITS 1.0 1.0 Section 1.1, before the first definition.

A3 Deleted reportable event definition.

N/A 1.0.A A4 The definition of Cold Condition has been incorporated into the MODES Table as MODE 4.

Table 1.1-1 1.0.C, 1.0.1.3.b A5 Adds Sections 1.2, Logical Connector, 1.3, Completion Times, and 1.4 Frequency, to the Technical Specifications to aid in the 1.2, 1.3, 1.4 N/A understanding and use of the new format and presentation style, and to establish positions not previously formalized.

A6 Deletes CTS definitions of Functional Test, Instrument Channel, Protective Actuation, Protective Function, Simulated Automatic N/A 1.0.F.1, 1.0.F.3, Actuation, Sensor, Limiting Condition for Operation (LCO), Limiting Safety System Setting (LSSS), Reactor Vessel Pressure, 1.0.F.8, 1.0.F.9, Transition Boiling, Electrically Disarmed Control Rod, Rated Recirculation Flow, Top of Active Fuel, Rod Density, Purge-1.0.F.11, Purging, and Venting, and deletes RETS definitions of Instrument Channel Calibration, Instrument Channel Functional Test, 1.0.F.13, 1.0.G, Instrument Check, Logic System Functional Test, Member(s) of the Public, Off Gas Treatment System, Operable, Process 1.0.H, 1.0.P, Control Program (PCP), Rated Thermal Power, Solidification, Source Check, Treatment, and Unrestricted Area, since 1.0.U.4, 1.0.V, Specifications referring to them no longer contain their use, or no longer are retained in the FitzPatrick ITS.

1.0.Y, 1.0.Z, 1.0.AA, 1.0.AB, and 1.0.AC; RETS 1.0.B, 1.0.C, 1.0.D, 1.0.E, 1.0.F, 1.0.G, 1.0.1, 1.0.J, 1.0.K, 1.0.M, 1.0.N, 1.0.0, and 1.0.P JAFNPP Page 1

TABLE A -ADMINISTRATIVE CHANGES MATRIX CHAPTER 1.0 - USE AND APPLICATION DOC #

SUMMARY

ITS SECTION CTS SECTION A7 Revises the wording for the definition of Instrument Channel Calibration to more accurately reflect the intent for OPERABILITY CHANNEL 1.0.F.2 of a channel; i.e., not all channels will have a "required" actuation, alarm, or trip function, and conversely, some channels may CALIBRATION have a "required" display function. Therefore, the word "required" has been included. In addition, specific CHANNEL definition CALIBRATION requirements for RTDs and thermocouples are added to the definition of Instrument Channel Calibration. Also, the definition of Instrument Channel Calibration has been modified to provide an allowance to perform the test "by means of any series of sequential, overlapping, or total channel steps."

A8 The phrase "or actual," in reference to the injected signal for the Instrument Channel Functional Test, has been added as an CHANNEL 1.0.F.5 explicit option to the currently required simulated signal. Revises the wording for the definition of Instrument Channel Functional FUNCTIONAL TEST Test to more accurately reflect the intent for OPERABILITY of a channel; i.e., not all channels will have a "required" alarm definition and/or initiating action, therefore, the word "required" has been included. Also, the definition of Instrument Channel Functional Test has been modified to provide an allowance to perform the test "by means of any series of sequential, overlapping, or total channel steps."

A9 Revises the wording for the definition of LSFT to more accurately reflect the intent for OPERABILITY of a channel; i.e., not all LOGIC SYSTEM 1.0.F.7 channels will have a "required" relay, contact, trip unit, or solid state logic element, and conversely, some channels may have a FUNCTIONAL TEST "required" display function. Therefore, the word "required" has been included, definition A10 The MCPR and MFLPD definitions have been revised for clarity and for consistency with the ISTS wording.

MINIMUM CRITICAL 1.0.U.1, 1.0.U.2, POWER RATIO and and 1.0.U.3 MAXIMUM FRACTION OF LIMITING POWER DENSITY definitions Al1 Modifies the definition of Operable to a) change the word "or" in reference to cooling or seal water to "and"; b) change the word OPERABLE-1.0.J "or" in reference to other auxiliary equipment to "and"; and c) changes the word "and" in reference to normal and emergency OPERABILITY electrical power sources to "or". Currently, when one source is not available, the definition of Operable alone requires the definition supported features to be declared inoperable. However, CTS LCO 3.0.E allows the features to be considered Operable provided at least one source of power is still available and their redundant features are Operable. CTS LCO 3.0.E requirements are incorporated intoITSLCO_3.8.1_ACTIONS for when a diesel or offsite power source is inoperable.

A12 Deletes the portion of the Rated Power definition that refers to a steady state nuclear steam supply output, since this is RATED THERMAL 1.0.N consistent with the license condition (the license condition refers to a specific reactor power level only).

POWER definition A13 Modifies the definition of Staggered Test Basis, allowing the minimum Surveillance interval to be specified in the Surveillance STAGGERED TEST 1.0.X Requirements' Frequency column of the applicable LCOs, independent of the number of subsystems.

BASIS definition

_1__

1 JAFNPP Page 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 1.0- USE AND APPLICATION DOC #

SUMMARY

ITS SECTION CTS SECTION A14 The definitions of Primary Containment Isolation Actuation Instrumentation Response Time and RPS Response Time have RPS RESPONSE 1.0.F.6, 1.0.F.10, been modified with an allowance to not measure the response times of certain components, provided that the components and TIME and 4.1.A footnote *,

methods for verification have been previously reviewed and approved by the N RC.

ISOLATION 4.2.A footnote

  • INSTRUMENTA TION RESPONSE TIME A15 Adds the definitions of ACTIONS, AVERAGE PLANAR LINEAR HEAT GENERATION RATE, LEAKAGE, LINEAR HEAT
ACTIONS, N/A GENERATION RATE, SHUTDOWN MARGIN, THERMAL POWER, and TURBINE BYPASS SYSTEM RESPONSE TIME.

AVERAGE PLANAR LINEAR HEAT GENERATION RATE, LEAKAGE, LINEAR HEAT GENERATION RATE, SHUTDOWN MARGIN, THERMAL POWER, TURBINE BYPASS SYSTEM RESPONSE TIME definitions A16 The Primary Containment Isolation Actuation Instrumentation Response Time definition for the Main Steam Isolation Valves ISOLATION 1.0.F.6 (MSIV) has been modified to address the ISOLATION INSTRUMENTATION RESPONSE TIME of all isolation valves.

INSTRUMENTA TION RESPONSE TIME A17 Adds the average reactor coolant temperature, the reactor vessel head closure bolt tensioning, and that fuel is in the vessel MODE definition 1.0.1 requirements to the definition of Mode.

A18 Deletes the definition of Surveillance Frequency Notation/Intervals since the all SR Frequencies in the FitzPatrick ITS are N/A 1.0.T directly specified.

A19 Deletes the definition of Trip System since it is not necessary.

N/A 1.0.F.12 A20 Deletes the definition of Operating since it is not necessary.

N/A 1.0.K A21 Deletes the definitions of Operating Cycle and Refueling Outage since all SR Frequencies in the FitzPatrick ITS are directly N/A 1.0.L, 1.0.Q specified as a time (e.g., 24 months).

Page 3 JAFNPP

TABLE A -ADMINISTRATIVE CHANGES MATRIX CHAPTER 1.0- USE AND APPLICATION JAFNPP DOC #

SUMMARY

ITS SECTION CTS SECTION A22 Deletes the definitions of Primary Containment Integrity and Secondary Containment Integrity; all the requirements are N/A 1.0.M, 1.0.S specifically addressed in the LCOs for the Primary Containment and Secondary Containment, along with the remainder of the LCOs in the Containment Systems Section.

A23 Deletes the definition of Safety Limits since it is duplicative of 10 CFR 50.36 and ITS Chapter 2.0.

N/A 11.0.R A24 The definitions of Refuel Mode, Run Mode, Shutdown Mode (cold and hot shutdown), and Startup/Hot Standby have been Table 1.1-1 1.0.1.1, 1.0.1.2, included in the ITS MODES Table.

1.0.1.3, 1.0.1.4 A25 Deletes the portion of the Refuel Mode definition stating that the refueling interlocks are in service when the mode switch is in N/A 1.0.1.1 the refuel position.

A26 Deletes the portion of the Run Mode definition that the Reactor Protection System is energized with APRM protection (excluding N/A 1.0.1.2 the 15% high flux trip) and the RBM interlocks are in service when the mode switch is in the run position.

A27 Deletes the portions of the Startup/Hot Standby definition that the low pressure main steam line isolation valve closure trip is N/A 1.0.1.4 bypassed, the Reactor Protection System is energized with APRM (15 percent), and IRM neutron monitoring system trips and control rod withdrawal interlocks are in service when the mode switch is in the startup/hot standby position.

Page 4

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 2.0 - SAFETY LIMITS DOC #

SUMMARY

ITS SECTION CTS SECTION Al Editorial changes, reformatting, and revised numbering.

2.0 1.1, 1.2, 6.7 A2 The CTS requirement, that in the event of a SL violation reactor operation shall only be resumed in N/A 6.7.(A) accordance with the provisions of 10 CFR 50.36(c)(1)(i), has been deleted, since it is duplicative of 10 CFR 50.36.

1_

1 A3 The Applicability of the Reactor Coolant System Pressure Safety Limits has been changed from "at any 2.1.2 1.2.1 time when irradiated fuel is present in the reactor vessel" to "in all MODES."

PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.0 - LCO AND SR APPLICABILITY DOC #

SUMMARY

ITS SECTION CTS SECTION Al Editorial changes, reformatting, and revised numbering.

3.0 3/4.0 A2 The CTS phrase "Limiting Conditions for Operation...shall be applicable..." has been replaced with the LCO 3.0.1 3.0.A phrase "LCOs shall be met..." In addition the ITS identifies specific exceptions to other LCO Applicabilities thus eliminating any interpretations that may be required, and avoiding any confusion.

A3 The CTS words that state that the LCO is complied with if the Actions are completed (within the specified LCO 3.0.2 3.0.B time interval) or if the LCO is restored prior to the time interval expiring have been reworded to be consistent with the format of other LCO 3.0 Specifications. In addition, the ITS identifies specific exceptions to other LCO Applicabilities thus eliminating any interpretations that may be required, and avoiding any confusion.

A4 A phrase has been added to the CTS for clarity. The ITS includes the phrase "LCO 3.0.3 is only LCO 3.0.3 3.0.C applicable in MODES 1, 2, and 3." This phrase has been added since CTS provides no guidance in this area. No further ACTIONS would be required to be performed if the plant were already in MODE 4 or 5 since the CTS only requires the plant to be placed in MODE 4.

A5 Two CTS Surveillance Requirements, 4.0.A and 4.0.C have been combined to form ITS SR 3.0.1. ITS SR 3.0.1 4.0.A, 4.0.C SR 3.0.1 rewords the current requirements to be consistent with the format of other LCO 3.0 Specifications. ITS SR 3.0.1 also adds clarifying words specifying that "failure to meet a Surveillance, whether such failure is experienced during the performance of the Surveillance or between performances of the Surveillance, shall be failure to meet the LCO." CTS implies that failure to meet the Surveillance means failure to meet theLCO,_howeverITSSR_3.0.1_provides this information in a clearer manner.

A6 The CTS allows the Surveillance Frequency to be extended by 25% each Surveillance interval. The ITS SR 3.0.2 4.0.B rewords the current requirement to be consistent with the format of other LCO 3.0 Specifications. The ITS also adds the sentence "Exceptions to this Specification are stated in the individual Specifications,"

to acknowledge the explicit use of exceptions in various Surveillances. The basic application of the 25%

extension to routine Surveillances is maintained.

PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.0 - LCO AND SR APPLICABILITY DOC #

SUMMARY

ITS SECTION CTS SECTION A7 When it is determined that a Surveillance Requirement has not been performed, the CTS provides SR 3.0.3 4.0.C allowances for delay into the ACTIONS requirements for up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for those specifications which include out of service times of less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The CTS has been revised to explicitly state the required ACTIONS if the Surveillance is not performed within the delay period or if the Surveillance is performed within the delay period but it is not met. The ITS requires the LCO to be immediately declared not met, and the applicable Condition(s) to be entered if the Surveillance is not performed within the delay period. The ITS also requires these same actions when the Surveillance is performed within the delay period but is not met.

A8 The CTS does not permit entry into a MODE or other specified condition when an LCO is not met and the LCO 3.0.4 3.0.D associated ACTION requires a shutdown if they are not met within a specified time interval. Exceptions to these requirements are stated in the individual specifications. The ITS rewords the current requirement to be consistent with the format of other LCO 3.0 Specifications. In addition, ITS LCO 3.0.4 states that the LCO is only applicable for entry into a MODE or other specified condition in the Applicability in MODES 1, 2, and 3.

A9 The CTS states that this LCO is an exception to LCO 3.0.B (ITS 3.0.2). The ITS includes these LCO 3.0.5 3.0.F requirements and also adds clarifying words specifying that the exception to LCO 3.0.2 is for the system returned to service under administrative control to perform the testing required to demonstrate OPERABILITY. This clarification eliminates any interpretations that may be required, and avoids any confusion.

A10 ITS LCO 3.0.6 is added to provide guidance regarding the appropriate actions to be taken when a single LCO 3.0.6 N/A inoperability (e.g., a support system) also results in the inoperability of one or more related systems (e.g.,

supported system(s)). The existing Technical Specifications and various NRC guidance documents have not provided a consistent approach to the combined support/supported inoperability.

Al1 A requirement has been added to CTS 3.0.C that requires entry into LCO 3.0.3 when directed by the LCO 3.0.3 3.0.C associated ACTIONS. This requirement is not included in the CTS since no specification explicitly directs entry into CTS 3.0.C. Since the ITS also uses this method of entry into LCO 3.0.3, this statement must be included. Changes to Specifications to explicitly require direct entry into LCO 3.0.3 (e.g., ITS 3.5.1) in the ITS if certain conditions are not met, are discussed in the Discussion of Changes for the specific Specification.

JAFNPP PAGE 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.0 - LCO AND SR APPLICABILITY JAFNPP DOC #

SUMMARY

ITS SECTION CTS SECTION A12 The CTS does not permit entry into a MODE or other specified condition when an LCO's Surveillances SR 3.0.4 4.0.D have not been met within the applicable interval or as otherwise stated. The ITS rewords the current requirement to be consistent with the format of other LCO 3.0 Specifications. In addition, the ITS states that the SR is only applicable for entry into a MODE or other specified condition in the Applicability in MODES 1, 2, and 3.

A13 Not used.

N/A N/A PAGE 3

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS

SUMMARY

3.1.1, SHUTDOWN MARGIN Al Editorial changes, reformatting, and revised numbering.

3.1.1 3/4.3.A.1 A2 The CTS requires a sufficient number of control rods to be Operable so that the core could be made LCO 3.1.1 3.3.A.1 subcritical in the most reactive condition during the operating cycle with the strongest control rod fully withdrawn and all other operable control rods fully inserted. The ITS 3.1.1 LCO has been editorially rewritten to require the Shutdown Margin (SDM) to be Ž 0.38% Ak/k, with the highest worth control rod analytically determined.

3.1.2, REACTIVITY ANOMALIES Al Editorial changes, reformatting, and revised numbering.

3.1.2 3/4.3.D, 3.3.E A2 The CTS in part requires that if Reactivity Anomalies exceed the limit, the reactor will be shutdown "until 3.1.2 ACTIONS 3.3.D the cause has been determined, and corrective actions have been taken as appropriate." These words A and B, LCO have been deleted; however, the proposed deletion of these words will not change this requirement 3.0.4 since the ITS requires that the plant be shutdown to MODE 3 within 84 hours9.722222e-4 days <br />0.0233 hours <br />1.388889e-4 weeks <br />3.1962e-5 months <br /> of finding Core Reactivity differences not within limits, and the ability to change MODES is generically controlled by the provisions of LCO 3.0.4 which states in part that "when an LCO is not met, entry into a MODE or other specified condition in the Applicability shall not be made except when the associated ACTIONS to be entered permit continued operation in the MODE or other specified condition in the Applicability for an unlimited period of time."

A3 The Frequency for the Reactivity Anomalies Surveillance of "During the Startup test program" has been N/A 4.3.D deleted from the CTS since this test program has already occurred and will not be repeated again.

A4 CTS 4.3.D is revised to replace the term "reactivity monitoring" with "reactivity measuring." Core SR 3.1.2.1 4.3.D reactivity is a calculated value and is not displayed as a continuous readout, which is analogous to a "monitored" value. Rather core reactivity is "measured" by considering actual control rod densities and performing appropriate calculations.

JAFNPP I

I

__L_

PAGE 1

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS

SUMMARY

3.1.3. CONTROL ROD OPERABILITY 1

r r

Editorial changes, reformatting, and revised numbering. In addition, the ITS Control Rod Operability Specification explicitly includes all conditions that can affect the ability of the control rods to provide the necessary reactivity insertion. The ITS also explicitly includes the following: a) All inoperable control rods (except stuck rods) are required to be fully inserted and disarmed; b) A control rod is considered "inoperable" and "stuck" if it is incapable of being inserted. Requirements are retained to preserve Shutdown Margin for this situation and the control rod is required to be disarmed; c) A control rod is considered "slow" when it is capable of providing the scram function, but may not be able to meet the assumed time limits. The scram reactivity used in the safety analysis allows for a specified number of slow rods. d) Special considerations are provided for non-conformance to the banked position withdrawal sequence (BPWS), due to inoperable control rods, at < 10% of Rated Thermal Power. Also, ITS 3.1.3 Action Table Note, "Separate Condition entry is allowed for each control rod," and a Note to ITS 3.1.3 Required Action for Condition A and Required Action C, which allows for bypassing the Rod Worth Minimizer (RWM) if necessary for continued operation, have been exclusively included.

3.1.3, 3.1.3 ACTIONS Note, 3.1.3 Condition A and Required Action C.1 Notes A2 The CTS requires that the plant can not be restarted after finding stuck control rods "unless N/A 3.3.A.2.a (1) investigation has shown that the cause of the failure is not a failed control rod drive collet housing, and (2) adequate shutdown margin testing has been demonstrated as required by Specification 4.3.A. If investigation shows that the cause of the control rod failure is a cracked collet housing, or if this possibility cannot be ruled out, the reactor shall not be restarted until the affected control rod drive has been replaced or repaired." This requirement has been deleted since it is duplicative of the requirements of ITS LCO 3.0.4.

A3 The CTS requires that for stuck control rods a SDM test be performed "to demonstrate under this SR 3.1.1.1, 4.3.A.2.d condition that the core can be made subcritical for any reactivity condition during the remainder of the definition of operating cycle with the analytically determined, highest worth control rod capable of withdrawal, fully SDM withdrawn, and all other control rods capable of insertion, fully inserted." The ITS requires SR 3.1.1.1 to be performed if a rod is withdrawn and can not be inserted (stuck). SR 3.1.1.1 is the proposed SDM test.

In the proposed ITS, the definition for SDM requires in part that "all control rods are fully inserted except for the single control rod of highest reactivity worth, which is assumed to be fully withdrawn. With control rods not capable of being fully inserted, the reactivity worth of these control rods must be accounted for in the determination of SDM." Therefore the present requirements of the CTS have been incorporated into the definition of SDM.

JAFNPP Al 3/4.3.A.2, 3/4.3.B.1, 3/4.3.B.2, 3/4.3.C.3 I

I I

PAGE 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A4 The CTS LCO requirement that control rods be coupled to the drive is presented in ITS SR 3.1.3.5, SR 3.1.3.5 3.3.B.1 making it a requirement for control rods to be considered OPERABLE.

A5 The CTS LCO requires that control rods with scram times greater than those permitted in CTS 3.3.C.3 be SR 3.1.3.4 3.3.A.2.c, declared inoperable. The requirement that maximum control rod scram insertion time to notch position 4 3.3.C.3 be

A6 The statement in CTS 3.3.B.1 that this requirement does not apply in the refuel condition when the N/A 3.3.B.1 reactor is vented, and that two control rods may be removed as long as Specification 3.3.A.1 is met, has been deleted since it duplicates an identical and more appropriately placed requirement in CTS 3.10.A.5 (ITS_3.10.6)._A 3.1.4, CONTROL ROD SCRAM TIMES Al Editorial changes, reformatting, and revised numbering.

3.1.4 3/4.3.C, 3.3.E A2 CTS 4.3.C.1 requires the Rod Worth Minimizer (RWM) to be Operable during scram time testing when Table 3.3.2.1-1 4.3.C.1 below 10% RTP. However, CTS 3.3.B.3 already requires the RWM to be Operable when in Startup or Function 2 Run MODES and less than 10% RTP. Therefore, this requirement is duplicative of the requirement in Applicability ITS 3.3.2.1 and is deleted from ITS 3.1.4.

A3 In CTS 3.3.C.3, the maximum insertion time is specified in terms of "90% insertion". Scram times are Table 3.1.4-1 3.3.C.3 measured from signals generated by switches corresponding to control rod notch positions. The Note 2 proposed change will specify scram insertion time limits (in ITS Table 3.1.4-1 Note 2) in terms of "notch position" within a specified number of seconds. This terminology is consistent with the other scram time limits specified in CTS 3.3.C.1 and CTS 3.3.C.2.

3.1.5, CONTROL ROD SCRAM ACCUMULATORS Al Editorial changes, reformatting, and revised numbering.

3.1.5 3.3.A.2.d, 4.3.A.2.c PAGE 3 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS

SUMMARY

ITS SECTION CTS SECTION The CTS requirement governing control rod drive (CRD) hydraulic control unit (HCU) accumulators is not 3.1.5 3.3.A.2.d associated with an Applicability statement governing when the accumulator and the associated rod must be Operable. However, the Applicability is assumed to be MODES 1 and 2 since the current default actions in CTS 3.3.A.2.e are to be in Hot Shutdown in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Therefore, the ITS Applicability is MODES 1 and 2.

A new Note has been added to the CTS ("Separate Condition entry is allowed for each control rod scram 3.1.5 ACTIONS 3.3.A.2.d accumulator") to provide more explicit instructions for proper application for the new ACTIONS for Note Technical Specification compliance. In conjunction with ITS 1.3 - "Completion Times," this Note provides direction consistent with the intent of the existing ACTIONS for inoperable control rod accumulators.

.6I R ROD PATTERN CONTROL Al Editorial changes, reformatting, and revised numbering.

3.1.6 3.3.B.3.e, 3.3.B.3.f A2 The CTS requires that if the requirements of BPWS can not be met, "the reactor shall not be restarted."

N/A 3.3.B.3.f This requirement has been deleted since it is duplicative of the requirements of ITS LCO 3.0.4.

3.1.7, STANDBY LIQUIDCONTROL SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.1.7 3/4.4 A2 CTS 3.4.C states that the solution temperature including the pump suction piping temperature has to be SR 3.1.7.2, SR 3.4.C, 4.4.C.2 maintained above the temperature limits; however, CTS 4.4.C.2 only requires the solution temperature to 3.1.7.3 be checked daily. The ITS has two separate surveillances, which require that both the temperature of the sodium pentaborate solution and the pump suction piping be verified every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Since the intent of theCTSSurveillance is to check both locations,_this change clarifies this intent.

PAGE 4 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS JAFNPP

SUMMARY

3.1.8. SCRAM DISCHARGE VOLUME VENT AND DRAIN VALVES Al Editorial changes, reformatting, and revised numbering.

3.1.8 3.3.E, 4.3.A.2.b, 4.3.A.2.e, 4.3.C.3 A2 The requirement to fully cycle the scram discharge volume vent and drain valves is covered by two SR 3.1.8.2 4.3.A.2.e, duplicate Surveillances in the CTS. The ITS combines these tests into one surveillance. In addition, 4.3.C.3.b since the 92 day surveillance frequency in one of the CTS requirements is consistent with the Inservice TestingRequirements,_theITSFrequency is_"In accordance with theInserviceTestingProgram".

PAGE 5

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.2 - POWER DISTRIBUTION LIMITS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.2.1, AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)

Al Editorial changes, reformatting, and revised numbering.

3.2.1 3/4.5.H A2 CTS 3.5.H requires the APLHGR be within limits "during power operations." CTS 4.5.H only requires the 3.2.1 3/4.5.H limit to be checked when thermal power is Ž 25% RTP. In addition, consistent with these requirements, if Applicability APLHGR is not restored to within limits when thermal power is Ž 25% RTP, the current actions of CTS 3.5.H require power to be reduced to < 25% RTP. Therefore, the ITS Applicability for the APLHGR specification is "THERMAL POWER >_ 25% RTP".

A3 The CTS requires the reactor power be reduced "to less than 25% of rated power within the next four N/A 3.5.H hours or until the APLHGR is returned to within the prescribed limits". The phrase "or until the APLHGR is returned to within the prescribed limits" is not included in the ITS, since it is redundant to ITS LCO 3.0.2.

3.2.2, MINIMUM CRITICAL POWER RATIO (MCPR)

Al Editorial changes, reformatting, and revised numbering.

3.2.2 3.1.B, 4.1.C, 4.1.D A2 CTS 3.1.8 requires the MCPR be within limits of the COLR "during power operations." CTS 4.1.C only 3.2.2 3.1.B, 4.1.C requires the limit to be checked when thermal power is Ž 25% RTP. In addition, consistent with these Applicability requirements, if MCPR is not restored to within limits when thermal power is Ž 25% RTP, the current actions of CTS 3.1.B require power to be reduced to < 25% RTP. Therefore, the ITS Applicability for the MCPR specification is "THERMAL POWER Ž 25% RTP".

A3 The CTS requires the reactor power be reduced "to less than 25% of rated power within the next four N/A 3.1.B hours or until the MCPR is returned to within the prescribed limits". The phrase "or until the MCPR is returned to within the prescribed limits" is not included in the ITS, since it is redundant to ITS LCO 3.0.2.

3.2.3, LINEAR HEAT GENERATION RATE (LHGR)

Al Editorial changes, reformatting, and revised numbering.

3.2.3 3/4.5.1 JAFNPP PAGE 1

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.2 - POWER DISTRIBUTION LIMITS JAFNPP DOC #

SUMMARY

ITS SECTION CTS SECTION A2 The CTS requires the reactor power be reduced "to less than 25% of rated power within the next four N/A 3.5.1 hours1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or until the LHGR is returned to within the prescribed limits". The phrase "or until the LHGR is returned to within the prescribed limits" is not included in the ITS, since it is redundant to ITS LCO 3.0.2.

3.2.4, APRM GAIN AND SETPOINT Al Editorial changes, reformatting, and revised numbering.

3.2.4 4.1..B A2 Notes are added that indicate the proper relationship with respect to when the SRs are required. These SR 3.2.4.1 Note, 4.1.B Notes provide clarification and do not change any technical requirement of the Specification.

SR 3.2.4.2 Note A3 The CTS requires the determination of MFLPD on a daily basis during reactor power operation at Ž 25%

SR 3.2.4.1, SR 4.1.B RTP. The APRM high flux scram settings must be adjusted if necessary as specified in the Core 3.2.4.2 Operating Limits Report (COLR). ITS SR 3.2.4.1 will require the verification that MFLPD is within limits (consistent with LCO 3.2.4.a). ITS SR 3.2.4.2 requires the verification that each required APRM Neutron Flux -

High (Flow Biased) Allowable Value specified in the COLR is made applicable (i.e., LCO 3.3.1.1, "Reactor Protection System Instrumentation," Function 2.b of Table 3.3.1.1-1 Allowable Value is reduced by the ratio of FRTP to MFLPD) or that each required APRM gain be adjusted as specified in the COLR (i.e., such that the APRM readings are Ž 100% times MFLPD). This change clarifies the option to adjust the APRM gains instead of lowering the APRM Neutron Flux (Flow Biased) Allowable Value since this adiustment will equally compensate for any local flux peaking when any MFLPD is greater than the FRTP.

PAGE 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

0')q 1 1 RDQIPSINSTRUMENA~TATIOlN Editorial changes, reformatting, and revised numbering.

3.3.1.1 2.1.A.1.a, 2.1.A.1.b, 2.1.A.1.c, 2.1.A.2, 2.1.A.3, 2.1.A.4, 2.1.A.5, 2.2.1.A, 3/4.1.A, Tables 3.1-1, 4.1-1, and 4.1-2 A2 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.1.1 Table 3.1-1 with the intent of the CTS.

ACTIONS Notes 1.a Note and 1.b A3 The CTS Trip Level Settings (changed to Allowable Value) for the Mode Switch in Shutdown, Manual Table 3.3.1.1-1 Table 3.1-1 Scram, IRM Inoperative and APRM Inoperative Functions have been changed to NA in the ITS, since Allowable Trip there are no Allowable Values.

Values for Functions 1, Functions 1.b, 2, 4, and 8 2.d, 10, and 11 A4 One of the optional actions for when an APRM Flow Referenced Neutron Flux channel is inoperable is N/A Table 3.1-1 to insert all Operable rods within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> (i.e., being in MODE 3). The ITS does not include this action Note 3.A since the CTS (and ITS) Applicability for the Function is Mode 1. Thus entry into Mode 3 is not really required.

A5 One of the optional actions for when an APRM Fixed High Neutron Flux channel is inoperable is to N/A Table 3.1-1 insert all Operable rods within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> (i.e., being in MODE 3). The ITS does not include this action Note 3.A since the CTS (and ITS) Applicability for the Function is Mode 1. Thus entry into Mode 3 is not really required.d

__I PAGE 1 JAFNPP Al

i.

i, mro iimo i nuivici,4 i m i vaim

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A6 Not used.

N/A N/A A7 CTS Table 3.1-1 requires the High Reactor Pressure, High Drywell Pressure, and Reactor Low Water N/A Table 3.1-1, Level Functions to be Operable in the Refuel Mode. However, Note 7 to the Table effectively states including that these Functions are not required to be Operable when the reactor is subcritical and the reactor Notes 7 and water temperature is less than 212 degrees F. In addition, Note 9 states that the High Reactor 9

Pressure is not required in the Refuel Mode when the reactor pressure vessel head is not bolted to the vessel, which is the normal condition during Refueling. Thus, in the ITS these three Functions are not required when in MODE 5.

A8 CTS Table 3.1-1 Note 8 permits the High Drywell Pressure Function to be inoperable when primary N/A Table 3.1-1 containment integrity is not required in the Refuel and Startup Modes. Primary containment integrity in Note 8 the ITS is always required when in MODE 2. Thus the ITS does not include the MODE 2 portion of this Note.

In addition, the requirement for High Drywell Pressure Function in Refuel (MODE 5) has not been included as described in DOC A7 above. Therefore, the ITS does not include the MODE 5 portion of theNote.

A9 One of the optional actions for when a Turbine Control Valve Fast Closure or Turbine Stop Valve N/A Table 3.1-1 Closure channel is inoperable is to insert all Operable rods within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> (i.e., being in MODE 3). The Note 3.A ITS does not include this action since the CTS (and ITS) Applicability for the Function is > 29% RTP.

Thus entry into Mode 3 is not really required.

A10 The CTS states that functional tests and calibrations are not required on the part of the system that is SR 3.0.1 Table 4.1-1 not required to be operable or are tripped. If tests are missed on parts not required to be operable or Note 3, Table are tripped, then they shall be performed prior to returning the system to an operable status. This 4.1-2 Note 2 explicit requirement is not retained in the ITS since these allowances are already included in CTS 4.0.A (and retained in ITS SR 3.0.1).

All Not used.

N/A N/A A12 The CTS specifies that the instrumentation channel functional test will consist of injecting a simulated CHANNEL Table 4.1-1 electrical signal into the instrument channels for certain channels. This explicit allowance is not FUNCTIONAL Note 4 retained in the ITS since it is duplicative of the current and proposed CHANNEL FUNCTIONAL TEST TEST definition, definition PAGE 2 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A13 Not used.

N/A N/A A14 The CTS specifies that Response Time Testing and conformance to the test acceptance criteria for the RPS 4.1.A remaining channel components includes trip unit and relay logic. This requirement is not explicitly

RESPONSE

footnote

  • included in the ITS since the definition of RPS RESPONSE TIME and the Response Time SR ensure TIME the proper testing is performed.

definition, SR 3.3.1.1.15 A15 The explicit requirement to perform a quarterly Functional Test of the High Water Level in Scram CHANNEL Table 4.1-1 Discharge Instrument Volume Function is not included in the ITS, since the CTS (and ITS) require a CALIBRATION Functional CHANNEL CALIBRATION at the same Frequency, and the ITS definition of CHANNEL CALIBRATION definition Test requires a CHANNEL FUNCTIONAL TEST.

requirement for Trip Function 14 A16 The CTS specifies that the Trip Level Setting (changed to Allowable Value) of the IRM High Flux Table 3.3.1.1-1 Table 3.1-1 Function is ! 96% of full scale. In the ITS, the Allowable Value for this Function is

  • 120/125 divisions Function 1.a Trip Function of full scale, which is equivalent to 96% of full scale.

Allowable 3 Trip Level Value Setting A17 The CTS specifies that a Functional test of the RPS Channel Test switches are required to be SR 3.3.1.1.4 Table 4.1-1 performed. However, a clarification is added that this test is to exercise the automatic scram contactors Trip Function by either the RPS channel test switches or by performing a functional test of any automatic scram 3 Functional function. For clarity, the ITS requires performance of a functional test of the automatic scram contactors Test (DOC LA9 justifies relocation of methods to perform the functional test).

Frequency, including Note 1 A18 The CTS specifies that the APRM Flow Referenced Neutron Flux Scram Trip Setting shall be adjusted N/A 2.1.A.1.c(1) during single loop operation when required by Specification 3.5.J (The actual requirement is specified in CTS 3.5.K). This cross reference is not included in the ITS since it is redundant to the requirements in CTS 3.5.K (and maintained in the ITS).

JAFNPP PAGE 3

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

The CTS "Trip Level Setting" and "limiting safety system trip settings" are changed to "Allowable Value" in the ITS, since the CTS trip level settings and limiting safety system trip settings are considered Allowable Values.

Table 3.3.1.1-1 Allowable Values Table 3.1-1 Trip Level Setting, 2.1.A limiting safety system trip settings A20 The CTS does not have a specific CHANNEL CALIBRATION requirement for the APRM and IRM RPS SR 3.3.1.1.9 Table 4.2-3 Functions. However, the CTS does have a 92 day CHANNEL CALIBRATION requirement for the Instrument APRM and IRM Control Rod Block Functions. Therefore, consistent with this CTS requirement and with Calibration current practice, a Surveillance Requirement is included as ITS SR 3.3.1.1.9 to perform a CHANNEL Test for CALIBRATION on IRM Functon l.a and APRM Functions 2.a, 2.b, and 2.c every 92 days.

Functions 1, 2, 3, and 4 3.3.1.2, SRMINSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.1.2 3/4.3.B.4, 3/4.10..B A2 The CTS requirement for SRM response of 3 cps is based on a signal to noise ratio of > 2:1. For SR 3.3.1.2.4 4.3.B.4 clarity, the signal to noise ratio is specified in the ITS.

A3 The CTS does not have a specific CHANNEL CALIBRATION requirement for the SRM indication.

SR 3.3.1.2.7 Table 4.2-3 However, the CTS does have a 92 day CHANNEL CALIBRATION for the MODE 2 SRM Control Rod Instrument Block Function. Therefore, consistent with this CTS requirement and with current practice, a Calibration Surveillance Requirement is included as ITS SR 3.3.1.2.7 to perform a CHANNEL CALIBRATION every Test for 92 days.

Function 8 PAGE 4 JAFNPP A19

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

3.3.2.1, CONTROL ROD BLOCK INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.2.1 2.1.A.1.d, 3/4.2.C, Tables 3.2-3 and 4.2-3, 3/4.3.B.3, 3/4.3.B.5 A2 The requirements of the Rod Worth Minimizer (RWM) have been moved from a separate Specification 3.3.2.1 3/4.3.B.3 in the CTS to the ITS Control Rod Block Specification.

A3 Not used.

N/A N/A A4 The explicit requirement to perform a quarterly Functional Test of the RBM - Upscale and RBM -

CHANNEL Table 4.2-3 Downscale Functions is not included in the ITS, since the CTS (and ITS) require a CHANNEL CALIBRATION Instrument CALIBRATION at the same Frequency, and the ITS definition of CHANNEL CALIBRATION requires a definition Functional CHANNEL FUNCTIONAL TEST. In addition, the CTS Note that is associated with the channel Test functional test (This instrument is exempt...) is deleted from the CTS since the CHANNEL requirement FUNCTIONAL TEST is not required to be performed.

for Functions 6 and 7, including Note_5 A5 The CTS states that instrument checks (i.e., channel checks) are not required when the instruments are SR 3.0.1 Table 4.2-3 not required to be operable or are tripped. This explicit requirement is not retained in the ITS since Note 4 these allowances are already included in CTS 4.0.A (and retained in ITS SR 3.0.1).

A6 The CTS provides a cross reference to the Radiological Effluent Technical Specification (Appendix B)

N/A 3/4.D for those Radiation Monitoring Systems which provide an Isolation and Initiation Function. This cross reference has been deleted since the RETS appropriately discuss the requirements.

PAGE 5 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A7 ITS SR 3.3.2.1.8 adds an explicit requirement for a CHANNEL CALIBRATION of the recirculation loop SR 3.3.2.1.5, Table 4.2-3 flow signal portion of the RBM Upscale Function (which is flow biased). The flow signal provided to the SR 3.3.2.1.8 RBM Upscale Function is the same signal provided to the APRM Newton Flux - High (Flow Bias)

Function. A Note is added to ITS SR 3.3.2.1.5 and SR 3.3.2.1.8 to explain which SR performs the flow signal calibration.

3.3.2.2, FEEDWATER AND MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.2.2 3/4.2.F, Tables 3.2-6 and 4.2-6 A2 The CTS provides the option of either restoring the inoperable instrument channel to operable status or N/A Table 3.2-6 placing the inoperable channel in the tripped condition when one of the required feedwater pump Note la turbine and main turbine trip instruments is inoperable. The ITS does not include the option to restore the inoperable channel to Operable status, since the option of restoring inoperable instruments to an operable status is always permitted in the Technical Specifications.

A3 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.2.2 Table 3.2-6 with the intent of the CTS.

ACTION Note Note 1 A4 The CTS provides an explicit allowance to inject a simulated electrical signal into the measurement CHANNEL Table 4.2-6 channel as close to the sensor as practicable to satisfy the requirements of the Instrument Channel FUNCTIONAL Note 2 Functional Test. This explicit allowance is not retained in the ITS since it is duplicative of the current TEST Instrument Channel Functional Test definition in the CTS and the ITS CHANNEL FUNCTIONAL TEST definition definition.

A5 The CTS specifies that the limiting condition for operation for the instrumentation that provide a 3.3.2.2 3/4.2.F feedwater pump trip and main turbine trip are given in Table 3.2-6 and requires the feedwater pump turbine and main turbine trip instrumentation to be calibrated in accordance with CTS Table 4.2-6. This cross-reference to the Tables has been deleted since the ITS does not include a Table. All of the L

technical requirements of theCTSTables are included in theITSLCO andSurveillances.

JAFNPP PAGE 6

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A6 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level SR 3.3.2.2.3 Table 3.2-6 settings are considered Allowable Values.

Trip Level Setting 3.3.3.1, PAMINSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.3.1 3/4.2.H, Tables 3.2-8 and_4.2-8 A2 The ITS Applicability is specifically stated as MODES 1 and 2, consistent with the CTS applicability of 3.3.3.1 Table 3.2-6 Run and Startup/Hot Standby modes.

Applicability Note J A3 The requirement that the Containment High Range Radiation Monitor Function provides an automatic 3.3.6.1 Table 3.2-8 isolation of the containment vent and purge valves is being moved to ITS 3.3.6.1, Primary Containment footnote

  • IsolationInstrumentation.

A4 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each Function," which is consistent 3.3.3.1 Table 3.2-8 with the intent of the CTS.

ACTIONS Notes A and Note 2 F

A5 The ITS includes an ACTION that directs entry into the appropriate Conditions referenced in ITS Table 3.3.3.1 N/A 3.3.3.1-1 when two channels in the same Function are inoperable and the Completion Time for ACTION D restoration of one required channel has expired. The ACTION has been added since not all Functions have the sameACTIONS when the required channels are not restored.

A6 The CTS Table Instrument Functional Test is not applicable to any of the PAM instrumentation retained N/A Table 4.2-8 in the ITS (as indicated by "N/A" in the CTS). Therefore, the Instrument Functional Test requirement is not included in theITS.

PAGE 7 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

3.3.3.2. REMOTE SHUTDOWN SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.3.3.2 3/4.2.J, Table 3.2-10 A2 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each Function," which is consistent 3.3.3.2 3.2.J.2, with the intent of the CTS.

ACTIONS 3.2.J.3 Note 2 A3 Not used.

N/A N/A A4 The CTS requires a channel check on all the required instrument channels (not control switches). The SR 3.3.3.2.1 Table 3.2-10 ITS requires a CHANNEL CHECK for each required instrument channel that is normally energized, since no specific acceptance criteria would apply to the CHANNEL CHECK if an instrument channel were de-energized (since the instruments would not be indicating). However, this change does not modify any current requirements since all the existing channels are either energized or are a directly reading parameter._I 3.3.4.1, ATWS-RPT INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.4.1 3/4.2.G, Tables 3.2-7 and 4.2-7 A2 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.4.1 Table 3.2-7 with the intent of the CTS.

ACTIONS Note 1 Note A3 Not used.

N/A N/A A4 Not used.

N/A N/A A5 Not used.

N/A N/A JAFNPP PAGE 8

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A6 CTS Table 3.2-7 Footnote ** provides guidance in applying the Required Actions of CTS Table 3.2-7 N/A Table 3.2-7 Note 1.b. This Footnote is not retained in the ITS.

Footnote **

A7 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level SR 3.3.4.1.4 Table 3.2-7 settings are considered Allowable Values.

Trip Level Setting A8 The CTS specifies that the limiting condition for operation for the instrumentation that provide a 3.3.4.1 3/4.2.G recirculation pump trip are given in Table 3.2-7 and requires the recirculation pump trip instrumentation to be functionally tested, calibrated, and logic tested in accordance with CTS Table 4.2-7. This cross reference to the Tables has been deleted since the ITS does not include a Table. All of the technical requirements of theCTSTables are included in theITSLCO andSurveillances.

A9 Not Used N/A N/A 3.3.5.1, ECCS INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.5.1 3/4.2.B, Tables 3.2-2 and 4.2-2, 4.5.A.1.f, 4.5.A.3 A2 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.5.1 Table 3.2-2 with the intent of the CTS.

ACTIONS Notes 1 Note through 9 A3 The ITS includes an ACTION that directs entry into the appropriate Conditions referenced in ITS Table 3.3.5.1 N/A 3.3.5.1-1 when one or more channels are inoperable. The ACTION has been added since not all ACTION A I_

Functions have the same ACTIONS.

PAGE 9 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A4 The CTS provides a cross reference to the Radiological Effluent Technical Specification (Appendix B)

N/A 3/4.2.D for those Radiation Monitoring Systems which provide an Isolation and Initiation Function. This cross reference has been deleted since the RETS appropriately discuss the requirements.

A5 The CTS includes a note that states "This instrumentation is exempt from the functional test definition.

CHANNEL Table 4.2-2 The functional test will consist of injecting a simulated electrical signal into the measurement channel."

FUNCTIONAL Note 5 This definition is covered by the ITS CHANNEL FUNCTIONAL TEST and does not need to be specified TEST in this Specification.

definition A6 The CTS states that instrument checks (i.e., channel checks) are not required when the instruments are SR 3.0.1 Table 4.2-2 not required to be operable or are tripped. This explicit requirement is not retained in the ITS since Note 4 these allowances are already included inCTS 4.0.A_(and retained inITSSR_3.0.1).

A7 The column title "Total Number of Instrumentation Channels Provided by Design for Both Trip Systems" Table 3.3.5.1-1 Table 3.2-2 is proposed to be changed to a per Function basis in the ITS rather than the current per Trip System basis. Therefore, except as otherwise noted, the number of channels in the proposed column will be changed to identify the number of channels associated with the new ITS Function.

A8 The details in the CTS Table 3.2-2 "Total Number of Instrumentation Channels Provided by Design for Table 3.3.5.1-1 Table 3.2-2 Both Trip Systems" column identifying which systems are supported by the CTS Trip Functions have been deleted (e.g., Core Spray and RHR). ITS Table 3.3.5.1-1 is arranged to identify each Function providing support to a specific ECCS System. Therefore, all the Trip Functions in CTS Table 3.2-2 providing a support Function to the Core Spray System, Low Pressure Injection System (LPCI), High Pressure Coolant Injection (HPCI) System and the Automatic Depressurization System (ADS) Trip System A and B are now associated with the specific System in ITS Table 3.3.5.1-1, thus it is not necessary to identify this cross reference to each system.

A9 CTS Table 3.2-2 Item 12 identifies specific start timer setpoints for the "1st Pump" and "2nd Pump" for Table 3.3.5.1-1 Table 3.2-2 RHR (LPCI) Loops A and B. In ITS Table 3.3.5.1-1 Function 2.f, the specific LPCI pumps (e.g., A, D)

Function 2.f Item No. 12 are.identified and are associated along with the appropriateAllowableValues.

PAGE 10 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A10 CTS 3.2.B requires the Core and Containment Cooling System instrumentation to be Operable Table 3.3.5.1-1 3.2.B whenever the system(s) it initiates or controls are required to be operable as specified in CTS 3.5. In the ITS, the Applicability is specifically stated in the ECCS Instrumentation Table, in lieu of referencing the ECCS System Specification. The ITS Applicability is consistent with the CTS system Applicability, except as modified by the DOCs in ITS 3.5.1 and ITS 3.5.2.

All A Note has been included in the ITS to clarify that the action is only applicable to ITS 3.3.5.1 Functions 3.3.5.1 Table 3.2-2 3.a and 3.b, consistent with the intent of the CTS action.

Required Note 1.A Action B.2 Note A12 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level Table 3.3.5.1-1 Table 3.2-2 settings are considered Allowable Values.

Allowable Trip Level Value Setting A13 The explicit requirement to perform a quarterly Functional Test of the Drywell Pressure (non-ATTS),

CHANNEL Table 4.2-2 ADS - LPCI and CS Pump Discharge, and HPCI Suction Source Level Functions is not included in the CALIBRATION Functional ITS, since the CTS (and ITS) require a CHANNEL CALIBRATION at the same Frequency, and the ITS definition Test definition of CHANNEL CALIBRATION requires a CHANNEL FUNCTIONAL TEST.

requirement for Instrument Channels 2a), 5, and 6 A14 The CTS divides the Surveillance Requirements for Drywell Pressure and Reactor Pressure Functions Table 3.3.5.1-1 Table 4.2-2 as non-Analog Transmitter Trip System (ATTS) components and ATTS components. The ITS does not Functions 1.b, Instrument specify this explicitly in the ITS Table as each of the Functions are listed separately along with the 2.b, 2.h, and Channels 2a) associated Surveillance Requirements.

3.b and 2b)

A15 The CTS requirement that a calibration of the timers is included in the LSFT has been deleted, since it N/A Table 4.2-2 is duplicative of the CTS requirement (and maintained in the ITS) to perform a Channel Calibration of Note 9 the timers.

PAGE 11 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A16 The CTS specifies that the Condensate Storage Tank Low Level setting must be > 59.5 inches above Table 3.3.5.1-1 Table 3.2-2 the tank bottom. The ITS does not specify the reference point since it is implied by the associated Functions 3.d Item No. 17 name of the Function (Condensate Storage Tank Level). In addition, the CTS specifies that the and 3.e and 18 Suppression Pool High Level setting must be < 6 inches above normal level, with the normal Suppression Pool Water Level, as specified in CTS 3.7.A.1, being from 13.88 to 14.00 feet. The ITS is clarified to specifically state theAllowableValue as < 14.5_feet,_consistent with theCTS.

3.3.5.2, RCIC SYSTEM INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.5.2 3/4.2.B, Tables 3.2-2 and 4.2-2, 4.5.E.1.f A2 CTS 3.2.B requires the RCIC System instrumentation to be Operable whenever the RCIC System is 3.3.5.2 3.2.B required to be operable as specified in CTS 3.5. In the ITS, the Applicability is specifically stated as MODES 1, and MODES 2 and 3 with reactor steam dome pressure > 150 psig, in lieu of referencing the RCIC System Specification. The ITS Applicability is consistent with the CTS system Applicability.

A3 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.5.2 Table 3.2-2 with the intent of the CTS.

ACTIONS Notes 1,4, Note and 9 A4 The ITS includes an ACTION that directs entry into the appropriate Conditions referenced in ITS Table 3.3.5.2 N/A 3.3.5.1-1 when one or more channels are inoperable. The ACTION has been added since not all ACTION A Functions have the same ACTIONS.

A5 The CTS states that instrument checks (i.e., channel checks) are not required when the instruments are SR 3.0.1 Table 4.2-2 not required to be operable or are tripped. This explicit requirement is not retained in the ITS since Note 4 these allowances are already included inCTS 4.0.A_(and retained inITSSR_3.0.1).

JAFNPP PAGE 12

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A6 The CTS includes a note that states "This instrumentation is exempt from the functional test definition.

CHANNEL Table 4.2-2 The functional test will consist of injecting a simulated electrical signal into the measurement channel."

FUNCTIONAL Note 5 This definition is covered by the ITS CHANNEL FUNCTIONAL TEST and does not need to be specified TEST in this Specification.

definition A7 The explicit requirement to perform a quarterly Functional Test of the RCIC Suction Source Level CHANNEL Table 4.2-2 Function is not included in the ITS, since the CTS (and ITS) require a CHANNEL CALIBRATION at the CALIBRATION Functional same Frequency, and the ITS definition of CHANNEL CALIBRATION requires a CHANNEL definition Test FUNCTIONAL TEST.

requirement for Instrument Channel 6 A8 The CTS provides a cross reference to the Radiological Effluent Technical Specification (Appendix B)

N/A 3/4.2.D for those Radiation Monitoring Systems which provide an Isolation and Initiation Function. This cross reference has been deleted since the RETS appropriately discuss the requirements.

A9 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level Table 3.3.5.2-1 Table 3.2-2 settings are considered Allowable Values.

Allowable Trip Level Value Setting A10 The CTS specifies that the Condensate Storage Tank Low Level setting must be > 59.5 inches above Table 3.3.5.2-1 Table 3.2-2 the tank bottom. The ITS does not specify the reference point since it is implied by the associated Function 3 Item No. 16 name of the Function (Condensate Storage Tank Level).

_I iI__

4 PAGE 13 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

3.3.6.1. PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.6.1 1.2.2, 2.1.A.8, 2.2.2, 3/4.2.A, Tables 3.2-1, 3.2-2, 3.2-8, 4.1-1, 4.1-2, 4.2-1, 4.2-2, and 4.2-8 A2 The CTS specifies that Response Time Testing and conformance to the test acceptance criteria for the ISOLATION 4.2.A note

  • remaining channel components includes trip unit and relay logic. This requirement is not explicitly INSTRUMENT included in the ITS since the definition of RPS RESPONSE TIME and the Response Time SR ensure ATION the proper testing is performed.

RESPONSE

TIME definition, SR 3.3.6.1.8 A3 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.6.1 Table 3.2-1 with the intent of the CTS.

ACTIONS Notes 1,2, Note 2 and 3, Table 3.2-8 Note A.

A4 The CTS provides the option of either restoring the inoperable instrument channel to operable status or N/A Table 3.2-1 placing the inoperable channel in the tripped condition when there are two required instruments of a Note 1.b.3)

Trip Function inoperable. The ITS does not include the option to restore the inoperable channel to Operable status, since the option of restoring inoperable instruments to an operable status is always permitted in the Technical Specifications.

A5 The CTS Note that allows 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to perform a surveillance for those functions utilizing a two-out-of-two 3.3.6.1 SR Table 3.2-1 taken once logic has been clarified in the ITS by identifying the actual Functions involved (e.g., ITS Note 2 Note 2.a table 3.3.6.1 Functions 2.d and 2.q)._1_

1_

_1 JAFNPP PAGE 14

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A6 The requirement in the CTS to declare the affected system inoperable when the penetration is isolated N/A Table 3.2-1 is an unnecessary reminder that other Technical Specifications may be affected. This is essentially a Note 3.F "cross reference" between Technical Specifications and has not been included in the ITS.

A7 The Reactor Water Cleanup (RWC) System, High Pressure Coolant Injection (HPCI) Steam Line, and Table 3.3.6.1-1 Table 3.2-1 Reactor Core Isolation Cooling System (RCIC) Steam Line Area Temperature Functions specified in Functions 3.d, Trip CTS Table 3.2-1 have been separated to indicate the actual areas in which the channels are designed 3.e, 3.f, 3.g, Functions 11, to monitor.

3.h, 3.i, 4.d, 16, and 20 4.e, 4.f, 5.a, 5.b, and 5.c)

A8 The explicit requirement to perform a quarterly Functional Test of the SDC Reactor High Pressure, CHANNEL Table 4.2-1 RWCU Area High Temperature, Main Steam Line High Radiation, and HPCI/RCIC High Exhaust CALIBRATION Functional Diaphragm Pressure Functions is not included in the ITS, since the CTS (and ITS) require a CHANNEL definition Test for CALIBRATION at the same Frequency, and the ITS definition of CHANNEL CALIBRATION requires a Instrument CHANNEL FUNCTIONAL TEST.

Channels 1, 6, 8, and 12 A9 The CTS states that instrument checks, instrument functional tests, and calibration tests are not SR 3.0.1 Table 4.1-1 required when the instruments are not required to be operable or are tripped. This explicit requirement Note 3, Table is not retained in the ITS since these allowances are already included in CTS 4.0.A (and retained in ITS 4.1-2 Note SR 3.0.1).

2,Table 4.2-1 Note 4 A10 The CTS includes notes that state that this instrumentation is exempt from the functional test definition.

CHANNEL Table 4.1-1 The functional test will consist of injecting a simulated electrical signal into the measurement channel.

FUNCTIONAL Note 4, Table This definition is covered by the ITS CHANNEL FUNCTIONAL TEST and does not need to be specified TEST 4.2-1 Note 5 in this Specification.

-_definition Al1 The CTS requirement that a calibration of the timers is included in the LSFT has been deleted, since N/A Table 4.2-1 none of the Primary Containment Isolation loQic includes any time delay relays or timers.

Note 9 PAGE 15 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A12 The CTS Table 4.2-1 Note 8 cross reference to Table 4.1-2 is deleted since the Logic System SR 3.3.6.1.8 Table 4.2-1 Functional Testing requirements of the Reactor Low Water Level (Level 3) and Drywell Note 8 Pressure -

High Functions are directly included in ITS 3.3.6.1.

A13 Not used.

N/A N/A A14 Not used.

N/A N/A A15 The CTS identifies actions based on whether the inoperable channels are common to RPS or not 3.3.6.1 Table 3.2-1 common to RPS. The Actions have been clarified in the ITS by identifying the actual Functions ACTION A Notes 1.a.1),

involved.

1.a.2),

1.b.3)(a), and 1.b.3)(b)

A16 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level Table 3.3.6.1 Table 3.2-1 settings are considered Allowable Values.

Allowable Trip Level Value Setting A17 The CTS requires 2 Main Steam Line High Flow channels to be Operable per trip system. The title of Table 3.3.6.1-1 Table 3.2-1 the Function is "Main Steam Line High Flow." This term represents the flow in each of the four steam Function 1.c Trip Function lines. Therefore, the current requirement is interpreted to be 2 channels per main steam line (MSL), per 9

trip system, for a total of 16 channels. For clarity, in the ITS Table, the Function will require 2 channels perMSL.

3.3.6.2, SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.6.2 3/4.2.A, Tables 3.2-1, 4.1-1, 4.1-2, 4.2-1, RETS 3/4.8, RETS Tables 3.10 1 and 3.10-2 PAGE 16 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A2 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.6.2 Table 3.2-1 with the intent of the CTS.

ACTIONS Notes 1,2, Note and 3, RETS Table 3.10-1 Notes a and d

A3 The CTS identifies actions based on whether the inoperable channels are common to RPS. The 3.3.6.2 Table 3.2-1 Actions have been clarified in the ITS by identifying the actual Functions involved.

ACTION A Notes 1.a.1) and 1.b.3)(a)

A4 The CTS provides the option of either restoring the inoperable instrument channel to operable status or N/A Table 3.2-1 placing the inoperable channel in the tripped condition when there are two required instruments of a Note 1.b.3)

Trip Function inoperable. The ITS does not include the option to restore the inoperable channel to Operable status, since the option of restoring inoperable instruments to an operable status is always permitted in the Technical Specifications.

A5 The CTS states that instrument checks, instrument functional tests, and calibration tests are not SR 3.0.1 Table 4.1-1 required when the instruments are not required to be operable or are tripped. This explicit requirement Note 3, Table is not retained in the ITS since these allowances are already included in CTS 4.0.A (and retained in ITS 4.1-2 Note 2, SR 3.0.1).

RETS Table 3.10-2 Note a A6 The CTS includes notes that state that this instrumentation is exempt from the functional test definition.

CHANNEL Table 4.1-1 The functional test will consist of injecting a simulated electrical signal into the instrument channel. This FUNCTIONAL Note 4, definition is covered by the ITS CHANNEL FUNCTIONAL TEST and does not need to be specified in TEST RETS Table this Specification.

definition 3.10-2 Note i A7 The CTS requirement that a calibration of the timers is included in the LSFT has been deleted, since N/A Table 4.2-1 none of the Secondary Containment Isolation loqic includes any time delay relays or timers.

INote 9 PAGE 17 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A8 The explicit requirement to perform a quarterly Functional Test of the Refuel Area Exhaust and Reactor CHANNEL RETS Table Building Area Exhaust Functions is not included in the ITS, since the CTS (and ITS) require a CALIBRATION 3.10-2 CHANNEL CALIBRATION at the same Frequency, and the ITS definition of CHANNEL CALIBRATION definition instrument requires a CHANNEL FUNCTIONAL TEST.

channel functional test for instrument channels 2 and 3 A9 The CTS Note requirement that "there shall be two operable or tripped trip systems for each Trip N/A Table 3.2-1 Function, except as provided below" has been deleted since the other CTS Notes provide sufficient Note 1 guidance to take when channels are inoperable. In the ITS, the requirements in ITS Table 3.3.6.2-1 and theACTIONS clearly define the appropriate requirements when channels are inoperable in theITS.

A10 The RETS requires the Standby Gas Treatment (SGT) System actuation instrumentation to be Table 3.3.6.2-1 RETS Table Operable to support the SGT System and the CTS requires the SGT System to be Operable whenever Functions 3 3.10-1 secondary containment integrity is required. In the ITS, the reference to the SGT System Specification and 4 is not used; the actual MODES and other specified conditions are specified, consistent with the Applicability ApplicabilitV in the ITS SGT System Specification.

PAGE 18 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION All CTS RETS Table 3.10-1 Note (c) requires to stop handling the refueling equipment or Note (d) requires N/A RETS Table the isolation of the Secondary Containment and to start the Standby Gas Treatment (SGT) System 3.10-1 Note c when the requirements for the Refuel Area Exhaust Monitor are not met. The option to only stop handling the refueling equipment is not retained in the ITS since it does not provide adequate protection during all MODES of plant operation. If operating in MODE 1, stopping this operation (stop handling the refueling equipment) will not provide sufficient protection for all postulated events during power operation. The requirement that this equipment must be Operable during handling the refueling equipment is retained in the Applicability of ITS 3.3.6.2-1, Footnote b, consistent with the current Applicability requirements in CTS RETS 3.8 (see A10). ITS Table 3.3.6.2-1 requires this Function to be Operable during MODES 1, 2 and 3 and Footnote b requires this Function to be Operable during CORE ALTERATIONS and during movement of irradiated fuel assemblies in secondary containment.

Therefore, the proposed Applicability will ensure the equipment is Operable during the conditions of postulated events. In addition, the ITS 3.3.6.2 ACTIONS will provide adequate compensatory actions when this instrumentation is inoperable. Changes to the actions in CTS RETS Table 3.10-1 Note (d) are discussed inM3_andL4,_therefore,_this change is considered administrative.

A12 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level Table 3.3.6.2-1 Table 3.2-1 settings are considered Allowable Values.

Allowable Trip Level Value Setting A13 The RETS details identifying how the Logic System Functional Test is to be performed (i.e., where LOGIC RETS Table possible using test jacks) has been deleted since it is duplicative of the ITS definition for Logic System SYSTEM 3.10-2 Note f Functional Test.

FUNCTIONAL TEST definition PAGE 19 A.

a JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

337.1_ CREVAS SYSTEM INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.7.1 3.11.A.1, 3.11.A.2, 4.11.A.3, RETS 3.10, RETS Tables 3.10-1 and 3.10-2 A2 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level SR 3.3.7.1.2 RETS Table settings are considered Allowable Values.

3.10-1 A3 Not used.

N/A N/A A4 The explicit requirement to perform a quarterly Functional Test of the CREVAS Air Inlet Radiation High CHANNEL RETS Table Function is not included in the ITS, since the CTS (and ITS) require a CHANNEL CALIBRATION at the CALIBRATION 3.10-2 same Frequency, and the ITS definition of CHANNEL CALIBRATION requires a CHANNEL definition instrument FUNCTIONAL TEST.

channel functional test for instrument channel 7 A5 The CTS states that instrument checks, instrument functional tests, and calibration tests are not SR 3.0.1 RETS Table required when the instruments are not required to be operable or are tripped. This explicit requirement 3.10-2 Note a is not retained in the ITS since these allowances are already included in CTS 4.0.A (and retained in ITS SR 3.0.1).

A6 The CTS includes notes that state that this instrumentation is exempt from the functional test definition.

CHANNEL RETS Table The functional test will consist of injecting a simulated electrical signal into the measurement channel.

FUNCTIONAL 3.10-2 Note i This definition is covered by the ITS CHANNEL FUNCTIONAL TEST and does not need to be specified TEST in this Specification.

definition JAFNPP PAGE 20

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A7 The RETS provides a conversion factor to convert the Main Control Room Ventilation Monitor reading N/A RETS Table of counts per minute (cpm) to microcuries per centimeter cubed (/Ci/cc). This conversion factor is not 3.10-1 Note i retained inITS since theAllowableValue units is maintained in cpm.

A8 The RETS specifies that the limiting condition for operation for the instrumentation that provide a LCO 3.3.7.1 RETS 3.10 CREVAS System trip are given in RETS Table 3.10-1 and requires the CREVAS System trip instrumentation to be surveilled in accordance with RETS Table 3.10-2. This cross-reference to the Tables has been deleted since the ITS does not include a Table. All of the technical requirements of the RETS Tables are included in the ITS LCO and Surveillances.

3.3.7.2, CONDENSER AIR REMOVAL PUMP ISOLATION INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.7.2 Tables 3.2-1 and 4.2-1, RETS 3.9, RETS Tables 3.10-1 and 3.10-2 A2 The requirement in CTS RETS 3.9.b to isolate the vacuum pump (or air removal pump) when the limits N/A RETS 3.9.b of CTS RETS Table 3.10-1 have been exceeded has been deleted since the associated actions for the Main Steam Line Radiation -

High Function in CTS RETS Table 3.10-1 Note (h) along with its reference toCTSAppendixA Table_3.2-1_provide the appropriate actions.

A3 The Table presentation of the LCO requirements has been changed such that the ITS does not use LCO 3.3.7.2 Table 3.2-1, Tables; the ITS LCO statement includes the CTS LCO requirements from the Tables.

RETS Table 3.10-1 A4 The RETS cross-reference to the Actions in Table 3.2-1 has been deleted, since the actions for the air N/A RETS Table removal pump are all in one ITS Specification.

1

_1_

3.10-1 Note h PAGE 21 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A5 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.7.2 CTS Table with the intent of the CTS.

ACTIONS 3.2-1 Notes 1 Note and 3.E, RETS Table 3.10-1 Note h A6 The CTS reference to those trip functions which are not common to RPS has been deleted since the N/A Table 3.2-1 Main Steam Line Radiation -

High Function is not common to RPS.

Notes 1.a.2 and 1.b.3.b)

A7 The CTS term PCIS initiation capability has been changed to condenser air removal pump isolation Surveillance Table 3.2-1 capability in the ITS since this Specification is concerning the condenser air removal pump isolation.

Requirements Note 2.b Note A8 The explicit requirement to perform a quarterly Functional Test of the Main Steam Line Radiation - High CHANNEL Table 4.2-1 Function is not included in the ITS, since the CTS (and ITS) require a CHANNEL CALIBRATION at the CALIBRATION instrument same Frequency, and the ITS definition of CHANNEL CALIBRATION requires a CHANNEL definition functional FUNCTIONAL TEST.

test for instrument channel 8 A9 The RETS cross-reference to the Surveillances in Table 4.2-1 has been deleted, since the N/A RETS Table Surveillances for the air removal pump are all in one ITS Specification.

3.10-2 Note g A10 The RETS requirement that a calibration of the timers is included in the LSFT has been deleted, since N/A RETS Table the Main Steam Line Radiation - High Function does not include any time delay relays or timers.

3.10-2 Note h Al1 The CTS Note requirement that "there shall be two operable or tripped trip systems for each Trip N/A Table 3.2-1 Function, except as provided below" has been deleted since the ITS requirements in the ITS LCO and Note 1 theACTIONS clearly define the appropriate requirements when channels are inoperable in theITS.

PAGE 22 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION A12 The ITS includes a Note to preclude placing the channel in trip if the associated isolation valve is 3.3.7.2 N/A inoperable. This clarification has been made since there is no system specification for the condenser Required air removal pump isolation valves and therefore the appropriate ACTIONS associated with valve Action A.2 inoperabilities are included in this Specification.

Note A13 The RETS cross-reference to the Surveillances in RETS Table 3.10-2 has been deleted, since the N/A RETS 3.9 Surveillances for the air removal pump are all in oneITSSpecification.

A14 The CTS "Trip Level Setting" is changed to "Allowable Value" in the ITS, since the CTS trip level SR 3.3.7.2.2 Table 3.2-1 settings are considered Allowable Values.

Trip Level Setting A15 The ITS is clarified by a Note that excludes the calibration of the radiation detectors associated with the SR 3.3.7.2.2 Table 4.2-1 Main Steam Line Radiation -

High Function during the quarterly test (once every 3 months). This is Note Note 11 consistent with the CTS, since the current requirements only require an instrument channel alignment (CHANNEL CALIBRATION) every 3 months using a current source, which implies the radiation detector is excluded from this Surveillance.

3.3.7.3, ESW SYSTEM INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.7.3 3/4.11.D A2 The CTS includes both instrumentation and the system components of the ESW System in one LCO 3.3.7.3 3/4.11.D Specification. The ITS splits the requirements into two Specifications, one for the instrumentation and one for the system. Therefore, a specific ITS LCO statement has been provided for the instrumentation.

A3 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.7.3 3.11.D with the intent of the CTS.

ACTIONS Note PAGE 23 I_

1

_I_

JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

3.3.8.1, LOP INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.3.8.1 3.2.1, Tables 3.2-2 and 4.2-2 A2 Not used.

N/A N/A A3 Adds ITS ACTIONS Note "Separate Condition entry is allowed for each channel," which is consistent 3.3.8.1 Table 3.2-2 with the intent of the CTS.

ACTIONS Note 10 Note A4 The CTS requires a "Minimum No. of Operable Instrument Channels Per Trip System." The ITS Table 3.3.8.1-1 Table 3.2-2 clarifies this by using the term "Required Channels Per Bus." This specifies the number of channels required to be Operable to ensure an EDG subsystem or EDG will start when required. In addition, the CTS Table column "Total Number of Instrument Channels Provided by Design for Both Trip Systems" has been deleted since only one trip system exists for each emergency bus.

A5 The ITS includes a Note to clarify which SRs are required to be performed on each of the LOP Surveillance Table 4.2-2 instrument Functions.

Requirements Note 1 A6 The explicit requirement to perform a quarterly Functional Test of the 4 kV Emergency Bus Under CHANNEL Table 4.2-2 Voltage Functions is not included in the ITS, since the CTS (and ITS) require a CHANNEL CALIBRATION instrument CALIBRATION at the same Frequency, and the ITS definition of CHANNEL CALIBRATION requires a definition functional CHANNEL FUNCTIONAL TEST.

test requirement for instrument channel 7

_____________ +/-

PAGE 24 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

ITS SECTION CTS SECTION DOC #

3 i.3. 8. 2,

EHb.

I-r L.

I I I I...'

I

  • I_.__vv

_i_,i_,_,.

Al Editorial changes, reformatting, and revised numbering.

3.3.8.2 3/4.9.G A2 The CTS provides the option of either restoring the inoperable monitoring assembly to Operable status N/A 3.9.G.1, or removing the associated RPS power supply from service when an assembly is inoperable. The ITS 3.9.G.2 does not include the option to restore the inoperable assembly to Operable status, since the option of restoring the inoperable assembly to an operable status is always permitted in the Technical Specifications.

A3 The CTS "setpoints" is changed to "Allowable Value" in the ITS, since the CTS setpoints are considered SR 3.3.8.2.2, 4.9.G.2 Allowable Values.

SR 3.3.8.2.3 PAGE 25 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

q A4 DIP(ICI II iATIN i fLOOPS* OPERATING Editorial changes, reformatting, and revised numbering.

Although not stated in the CTS, Thermal Hydraulic Stability applies for both two loop and single loop operation. This clarification is reflected in the ITS LCO, which requires operations to be outside the "Exclusion Region" of the power-to-flow map in both two loop and one loop operation, and in the associated Action.

The CTS 3.5.K.1 cross-reference to CTS 1.1.A has been deleted since the proposed Safety Limit is applicable at all times. As currently written, the safety limit would not be required to be met for up to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> after a single loop is in service. This is not the intent and would not be utilized in this manner. In addition, the CTS 3.5.K.1 cross-reference to the APRM Flow Referenced Neutron Flux control rod block in CTS 2.1.A and in 3.2.C have been deleted since the function has been relocated from the Technical Specifications (see DOCs for LCO 3.3.2.1).

3.4.1 LCO 3.4.1, 3.4.1 ACTION A N/A

-i 1

3.4.2, JET PUMPS I..

..-f-nfne nl niip nil h

ri Al Editorlal cnanges, reiorurLattLyi, d i

s u vI u,u,u The wording in the CTS was changed to require verification that one of the criteria be met, rather than require verification that none of the conditions exist simultaneously.

The CTS places requirements on individual jet pump differential pressure variation from the average of all jet pump differential pressures. The ITS places requirements on individual jet pump differential pressure variation from established patterns. This change is consistent with the recommendations provided in General Electric Service Information Letter (SIL) No. 330, Jet Pump Beam Cracks," and NUREG/CR-3052, "Closeout of IE Bulletin 80-07: BWR Jet Pump Assembly Failure." Since the jet pump diffuser to lower plenum differential pressure or relationship of one jet pump to the loop average is repeatable, both methods of comparison are considered equivalent.

3.4.2 34..

SR 3.4.2.1 4.6.G,

-I I

SR 3.4.2.1 4.6.G.3

-t 1

Al A2 A3 3.5.J, 3.5.K 3.5.J.1.a 3.5.J.1.a 3.5. K. 1 A2 A3 4.6.G, 4.6.G.A.b JAFNPP PAGE 1 4.6.G.3 SR 3.4.2.1 I

I 3.4.2 3/4.6.G I

I.,

I SR 3.4.2.1

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION 3.4.3, SAFETY/RELIEF VALVES Editorial changes, reformatting, and revised numbering.

3.4.3 t 3.6.E.l The CTS Applicability is "during reactor power operating conditions and prior to startup from a cold condition, or whenever reactor coolant pressure is greater than atmosphere and temperature greater than 212'F." The CTS Applicability of "during reactor power operating conditions," and "whenever reactor coolant pressure is greater than atmosphere and temperature greater than 2120F," are encompassed by the ITS MODES of Applicability (MODES 1, 2, and 3). The CTS Applicability, "prior to startup from a cold condition," is consistent with CTS 3.0.D and ITS LCO 3.0.4, which require that an LCO be met prior to entry into the MODE or other specified condition in the Applicability, and therefore are not required to be specified in ITS 3.4.3.

CTS 3.6.E.1 specifies that the Automatic Depressurization System (ADS) valves-shall be OPERABLE as required by CTS 3.5.D. This statement is a cross-reference that another Specification is also Applicable, and is not necessary to be in the ITS.

The CTS is revised to reflect that only each "required" S/RV need be manually opened, since the CTS states that only 9 of 11 S/RVs are required to be OPERABLE.

-j 3.4.3 Applicability L

I 3.6.E.l N/A SR 3.4.3.2 N/A 3/4.6.E, 3/4.6.E, 2.2.1.B 4.6.E.4 N/A 34.4 RC*.

OPERATIONAL LEAKAGE Al Editorial changes, reformatting, and revised numbering.

The requirement to record the reactor coolant leakage rate is not included in the ITS, since this requirement duplicates the requirements of 10 CFR 50 Appendix B,Section XVII (Quality Assurance Records).

3.4.4 N/A

-1 1

3/4.6.D 4.6.D.1 PAGE 2 JAFNPP Al A2 A3 A4 A5 Not used.

A2 N/A I

3.6. E. 1 3.6.E.1 N/A 3.4.4 IN/A

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM

SUMMARY

3.4.5.RCS5 LE AKAGEF DETECTION INSTRUMENTATION Al Editorial changes, reformatting, and revised numbering.

3.4.5 3/4.2.E, 3/4.6.D.4 A2 The CTS specifies that the limiting conditions for operation for the instrumentation that monitors drywell 3.4.5 3.2.E, 4.2.E leak detection are given in CTS Table 3.2-5. The ITS LCO explicitly specifies the RCS leakage detection instrumentation required to be Operable (i.e., Drywell Drain Sump Monitoring System, one channel of the drywell continuous atmospheric particulate system, and one channel of the drywell continuous atmospheric gaseous system, a Table is not used in the ITS. Therefore, this change deletes a cross reference to a Table which is not included in the ITS. Similarly, reference to CTS Table 4.2-5 has been deleted since in theITS,_a specific table is not used.

A3 CTS Table 3.2-5 Note 2, which refers to another Specification (CTS 3.6.D) for the associated Action N/A Table 3.2-5 requirements, does not need not be repeated in the ITS since the associated actions of this Specification Note 2 have been incorporated in ITS 3.4.5.

A4 CTS Table 4.2-5 Note 4, states that instrument checks are not required when these instruments are not N/A Table 4.2-5 required to be operable or are tripped. This Note is not included in the ITS because the Surveillances to Note 4 which the Note applies have been deleted and also because there is no trip position for this instrumentation.

A5 The Instrument Functional Test Frequency of the Floor Drain Sump Flow Integrator identified in Note 1 to SR 3.4.5.2 Table 4.2-5 Table 4.2-5 has been simplified to once every 31 days. The allowance to be able to change the Note 1 surveillance frequency by submitting failure rate data to the NRC is always an option and is not necessary for inclusion in the ITS.

3.4.6, RCSSPECIFIC ACTIVITY Al Editorial changes, reformatting, and revised numbering.

3.4.6 3/4.6.C A2 The requirement in CTS 4.6.1.b to perform an isotopic analysis of a sample of reactor coolant has been SR 3.4.6.1 4.6.C.1.b reworded to match the current wording in CTS 3.6.C.1. ITS SR 3.4.6.1 will require the verification that the reactor coolantDOSEEQUIVALENT_1-131_specific activity is_!_0.2_Ci/,qm.

PAGE 3 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION 3.4.7, RHR SHUTDOWN COOLING SYSTEM - HOT SHUTDOWN NONE NONE NONE NONE 3.4.8, RHR SHUTDOWN COOLING SYSTEM - COLD SHUTDOWN NONE NONE NONE NONE 3.4.9, RCS P/T LIMITS Al Editorial changes, reformatting, and revised numbering.

3.4.9 3/4.6.A A2 The CTS does not state any Applicability requirements. However, the limitations imposed by the CTS 3.4.9 3/4.6.A apply at all times, therefore, it can be implied that the Specification is also Applicable "At all times," as Applicability stated in the ITS Applicability.

A3 CTS 3.6.A.5.a is clarified by adding a NOTE that requires a determination be made whether the RCS is 3.4.9 Condition 3.6.A.5.a acceptable for continued operation whenever the P/T limit is not met, regardless of whether compliance A Note with the LCO is restored. This change only provides clarification, because CTS 3.6.A.5.a effectively contains this requirement.

A4 The CTS provides actions appropriate for placing the facility in a condition outside the MODE(S) of 3.4.9 Condition 3.6.A.5 Applicability when the Applicability is MODES 1, 2, and 3. Since certain PT limits apply even when not in A

MODES 1, 2, and 3, a new ITS Action was added, as described in DOC M4. Due to this addition, to clarify the use and application of applying the appropriate action depending on the MODE of operation, the specific clarification_"inMODES_1,_2,_or_3"_is added.

A5 Not used.

N/A N/A JAFNPP PAGE 4

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION A6 The requirement to record the various P/T limit temperatures and pressures is not included in the ITS, N/A 4.6.A.1, since this requirement duplicates the requirements of 10 CFR 50 Appendix B,Section XVII (Quality 4.6.A.2, Assurance Records).

4.6.A.3, 4.6.A.4, 4.6.A.6 A7 Thermal stresses on vessel components are dependent upon the temperature difference between the N/A 3/4.6.A.6.c idle loop coolant and the RPV coolant. ITS SR 3.4.9.5 ensures the temperature difference between the idle loop and the RPV coolant is acceptable. The CTS requirements to monitor the temperature difference between an idle loop and an operating loop are unnecessary and are deleted since they are redundant to the loop-to-coolant requirement of ITS SR 3.4.9.5. However, in accordance with procedures and as discussed in the Bases for ITS SR 3.4.9.4, the loop-to-coolant temperature check may use the operating loop temperature as representative of "coolant temperature".

A8 The Frequency of the CTS requirements to verify the reactor vessel head flange and flange temperatures SR 3.4.9.7 4.6.A.1.a, are within limits is either every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> or 30 minutes when the reactor vessel head flange falls below a Note, SR 4.6.A.1.b prescribed limit. Therefore, the first required Surveillance is 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> or 30 minutes after the specified 3.4.9.8 Note temperature is reached. In the ITS a Note has been added to clarify that the Surveillances are not required to be performed until 30 minutes after RCS temperature

  • 100°F or 1200F, respectively, consistent with the CTS requirements.

A9 Not used.

N/A N/A CTS 3/4.6.F, STRUCTURAL INTEGRITY NONE NONE NONE NONE PAGE 5 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM

SUMMARY

3-5.1Ff.

ECS - OPERATING~

Al Editorial changes, reformatting, and revised numbering.

3.5.1 3/4.5.A, 3/4.5.C, 3/4.5.D, 3/4.5.G, 4.6.E.3, 4.6.E.4, Table 4.2-2, 3/4.9.F A2 Existing specifications governing Operability and Surveillance Testing of Core Spray, Low Pressure 3.5.1 3/4.5.A, Coolant Injection, High Pressure Coolant Injection, and Automatic Depressurization System are 3/4.5.C, proposed to be combined into one specification, in recognition of the interdependence of the Operability 3/4.5.D, 3.5.G, requirements of these systems in meeting the assumptions of the design basis loss of coolant accident.

3.9.F.1 In addition, supporting requirements concerning maintenance of filled discharge piping and the LPCI MOV independent power supply have been included along with theSurveillances of theECCS.

A3 The CTS requires a simulated automatic actuation test of CS, LPCI, and HPCI. The ITS maintains this SR 3.5.1.10, SR 4.5.A.l.a, Surveillance, but includes a Note that excludes vessel injection/spray during the Surveillance. Since all 3.5.1.11 4.5.A.3, active components are testable and full flow can be demonstrated by recirculation through the test line, 4.5.C.1, coolant injection into the RPV is not required during the Surveillance. This Note, therefore, is explicit 4.5.D.1 recognition that the ITS Surveillance can be satisfied by a series of overlapping tests. Since surveillance testing of CS, LPCI, and HPCI do not presently require actual injection, and are all currently satisfied by a series of overlapping tests, the addition of the Note excluding vessel injection/spray is an administrative change. In addition, the CTS requires a simulated actuation test to be performed on the ADS valves. A Note is proposed to be added to exclude valve actuation,_similar to theECCS pumpsNotes.

A4 The CTS specifically state that the High Pressure Coolant Injection (HPCI) System and Automatic N/A 3.5.C.2, Depressurization System (ADS) valves are not required to be Operable during low power physics testing 3.5.D.3 and during reactor operator (criticality) training provided the reactor coolant temperature

  • 212 0F.

However, the CTS does not require the HPCI System to be Operable when the reactor coolant temperature is

  • 212°F and does-not require the ADS valves to be Operable in cold condition (i.e.,

reactor coolant temperature is

  • 212 0F). Therefore, these explicit redundant requirements are not retained in theITS.

PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION A5 Not used.

N/A N/A A6 The CTS requires that following any period where the LCPI or CS subsystems have not been maintained SR 3.0.1 4.5.G.2 in a filled condition; the discharge piping of the affected subsystem shall be vented from the high point of the system and water flow observed prior to declaring the subsystem operable. This requirement has not been included in theITS since it is redundant to theITSSR_3.0.1_requirements._

A7 The CTS requires that the "reactor shall not be started up with the RHR System supplying cooling to the LCO 3.0.4 3.5.A.4 fuel pool" and that "the RHR System shall not supply cooling to the spent fuel pool when the reactor coolant temperature is above 212 0F." These statements are not necessary since ITS LCO 3.0.4 ensures that theLPCI subsystems areOperable_(as required by another specification)_prior to enteringMODE_3.

A8 The CTS does not have a specific ACTION to enter LCO 3.0.C if sufficient ECCS subsystems are 3.5.1 ACTION H 3.5.A, 3.5.C, inoperable. However, entry into LCO 3.0.C is implicit, since ACTIONS are not provided for all instances 3.5.D, 3.9.F.3 of inoperabilities. In the ITS, a specific ACTION has been added that delineates when ITS LCO 3.0.3 is to be entered. In addition, the CTS requires that "the reactor shall be brought to cold condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />" when both LPCI independent power supplies are made or found to be inoperable. This specific default action has been changed to require entry into LCO 3.0.3 since the plant will be outside of its design basis in the condition. This portion of the change may be considered as more restrictive, but since the current Completion Times in CTS 39.F.3 and CTS 3.0.C are equivalent, this change is classified as administrative.

A9 The requirements in CTS 3.5.A.3.b and CTS 4.5.A.3.b concerning the LPCI cross tie valves have been SR 3.5.1.4 3.5.A.3.b, simplified into one Surveillance in the ITS that requires the verification that the valves are closed and 4.5.A.3.b power is removed from the electrical valve operator every 31 days. The details on how this is performed have been relocated to the Bases in accordance with DOC LA4.

A10 The CTS requires the associated ECCS pump (i.e., LPCI, CS, and HPCI) to be declared inoperable for N/A 3.5.G.1 the purposes of satisfying CTS 3.5.A and 3.5.C, when the associated pump discharge piping cannot be maintained in a filled condition. This explicit cross reference is not required in the ITS since this CTS requirement is included alongl with the requirements of the associated system.

PAGE 2 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION All CTS 4.5.G.1 requires the discharge piping of the required ECCS subsystem to be vented every month N/A 4.5.G.1 prior to the testing of the LPCI and CS subsystems. This explicit requirement to perform the surveillance prior to the testing of the LPCI and CS subsystems has been deleted. The requirement to perform this surveillance every 31 days is sufficient to ensure the discharge piping is full whenever the system is required to be Operable. This change is necessary since the ECCS subsystems flow rate Surveillances (e.g., CTS 4.5.A.1.b) are no longer tested every month. The Frequency of these Surveillances have been changed to "In accordance with the Inservice Testing Program" in recently approved Technical Specification Licensing Amendment 241. CTS 4.5.G.1 should have been modified during the process of the change. This will make the Surveillance consistent with other parts of the CTS and is therefore considered to be administrative since the current Surveillance Frequency is every 31 days.

A12 The requirement in CTS 3.9.F.2.a that operations may continue only if the other LPCI independent power N/A 3.9.F.2.a supply battery including its battery charger, and distribution system is Operable has been deleted. The ITS includes ACTIONS for when two LPCI subsystems are inoperable, thus this ACTION covers the inverter and bus. In addition, the requirements of the battery and battery charger are included in ITS 3.8.4, while the requirements of battery cell parameters are included in ITS 3.8.6. ITS 3.8.4 requires the associated LPCI subsystem to be declared inoperable immediately when the LPCI independent power supply battery or battery charger are inoperable. When a battery cell parameter is not within limits, either the battery is still Operable, or if not then the ACTIONS of ITS 3.8.6 require the associated LPCI battery to be declared inoperable (which will result in the associated LPCI subsystem being declared inoperable). Therefore, the specific requirement is not necessary to be included in the ITS.

A13 Not used.

N/A N/A 3.5.2, ECCS - SHUTDOWN Al Editorial changes, reformatting, and revised numbering.

3.5.2 3/4.5.F, 3/4.5.G, Table 4.2-2 JAFNPP PAGE 3

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION A2 The CTS does not directly address the OPERABILITY status of LPCI during alignment and operation for SR 3.5.2.4 Note 4.5.F Bases decay heat removal. The ITS includes a Note that states that one LPCI subsystem may be considered description OPERABLE during alignment and operation for decay heat removal, if capable of being manually realigned and not otherwise inoperable. This allowance is consistent with the CTS Bases description, which states that a LPCI subsystem operating in the shutdown cooling mode of RHR is considered operable for the ECCS function if it can be realigned manually (either remote or local) to the LPCI mode and is not otherwise inoperable.

A3 The CTS requires two low pressure Emergency Core Cooling subsystems to be Operable when work is LCO 3.5.2, 3.5.2 3.5.F.1, being performed with the potential for draining the vessel and requires one low pressure Emergency ACTION B 3.5.F.2 Core Cooling subsystem to be Operable when no work is being performed with the potential for draining the reactor vessel. The ITS is identical although the format of presentation of these requirements are different. The ITS requires two low pressure ECCS injection/spray subsystems to be Operable. It does not distinguish whether work is being performed with the potential for draining the reactor vessel (OPDRVs). If no OPDRVs are occurring and only one ECCS injection/spray subsystem is Operable, the Specification is met sinceITSACTIONB allows continuous operation in this condition.

A4 The CTS requirement to establish Secondary Containment Integrity has been changed in the ITS to a) 3.5.2 Required 3.5.F.4 initiate action to restore secondary containment to OPERABLE status, b) initiate action to restore one Actions D.1, standby gas treatment subsystem to OPERABLE status, and c) initiate action to restore isolation D.2, and D.3 capability in each required secondary containment penetration flow path not isolated. The CTS definition of Secondary Containment Integrity has been deleted as discussed in the Discussion of Changes for ITS Chapter 1.0. These three proposed Required Actions will ensure all aspects of secondary containment integrity are maintained.

A5 The CTS requires the associated ECCS pump (i.e., LPCI and CS) to be declared inoperable for the N/A 3.5.G.1 purposes of satisfying Specifications 3.5.A, 3.5.C and 3.5.E, when the associated pump discharge piping cannot be maintained in a filled condition. This explicit cross reference is not included in the ITS since this CTS requirement is included alonq with the requirements of the associated system.

PAGE 4 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION A6 CTS 4.5.G.1 requires the discharge piping of the required ECCS subsystem to be vented every month SR 3.5.2.3 4.5.G.1 prior to the testing of the LPCI and CS subsystems. This explicit requirement to perform the surveillance prior to the testing of the LPCI and CS subsystems has been deleted. The requirement to perform this surveillance every 31 days is sufficient to ensure the discharge piping is full whenever the system is required to be Operable. This change is necessary since the ECCS subsystems flow rate Surveillances (e.g., CTS 4.5.A.1.b) are no longer tested every month. The Frequency of these Surveillances have been changed to "In accordance with the Inservice Testing Program" in recently approved Technical Specification Licensing Amendment 241. CTS 4.5.G.1 should have been modified during the process of the change. This will make the Surveillance consistent with other parts of the CTS and is therefore considered to be administrative since the current Surveillance Frequency is everyn31 days.

A7 The CTS requires a simulated automatic actuation test of CS and LPCI. The ITS maintains this SR 3.5.2.6 Note Table 4.2-2 Surveillance, but includes a Note that excludes vessel injection/spray during the Surveillance. Since all Note 7 active components are testable and full flow can be demonstrated by recirculation through the test line, coolant injection into the RPV is not required during the Surveillance. This Note, therefore, is explicit recognition that proposed SR 3.5.2.6 can be satisfied by a series of overlapping tests. Since surveillance testing of CS and LPCI do not presently require actual injection, and are all currently satisfied by a series of overlapping tests, the addition of the Note excluding vessel injection/spray is an administrative change.

A8 The CTS requires that following any period where the LCPI or CS subsystems have not been maintained SR 3.0.1 4.5.G.2 in a filled condition; the discharge piping of the affected subsystem shall be vented from the high point of the system and water flow observed prior to declaring the subsystem operable. This requirement has not been included in theITS since it is redundant to theITSSR_3.0.1_requirements.

3.5.3, RCIC SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.5.3 3/4.5.E, 3/4.5.G A2 The CTS requires the RCIC pump to be declared inoperable when the associated pump discharge piping N/A 4.5.G.1 cannot be maintained in a filled condition. This explicit cross reference is not required in the ITS since thisCTS requirement is included alongqwith the requirements of theRCICSystem._I JAFNPP PAGE 5

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION A3 The CTS requires a simulated automatic actuation test of the RCIC System. The ITS maintains this SR 3.5.3.5 Note 4.5.E.1.a Surveillance, but includes a Note that excludes vessel injection during the Surveillance. Since all active 2

components are testable and full flow can be demonstrated by recirculation through the test line, coolant injection into the RPV is not required during the Surveillance. This Note, therefore, is explicit recognition that the ITS Surveillance can be satisfied by a series of overlapping tests. Since surveillance testing of RCIC does not presently require actual injection, and is currently satisfied by a series of overlapping tests, the addition of the Note excluding vessel injection is an administrative change.

A4 Not used.

N/A N/A A5 The CTS specifically state that the RCIC System is not required to be Operable during low power physics N/A 3.5.E.3 testing and during reactor operator (criticality) training provided the reactor coolant temperature _< 212 0F.

However, the CTS does not require the RCIC System to be Operable when the reactor coolant temperature is _*_212 0F._Therefore,_this explicit redundant requirement is not retained in theITS.

L _______

PAGE 6 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS

SUMMARY

361.1. PRIMARY CONTAINMENT Q.V. 1.

1 Al Editorial changes, reformatting, and revised numbering.

3.6.1.1 1.0.M, 3/4.7.A.2, 3.7.A.5.e, 3.7.A.8, 4.7.A.1, 4.7.A.3, 4.7.A.5.d A2 The CTS reference to "Primary Containment Integrity" has been deleted since the CTS definition of LCO 3.6.1.1 3.7.A.2 Primary Containment Integrity in CTS 1.O.M is incorporated into ITS 3.6.1.1, 3.6.1.2 and 3.6.1.3 and is no longer maintained as a separate definition in the ITS. ITS 3.6.1.1 requires that the primary containment shall be OPERABLE.

A3 The CTS requirement to perform required visual examination and leakage rate testing of the Primary SR 3.6.1.1.1 4.7.A.2.a Containment has been modified to include an exception for primary containment air lock testing, since in theITS,_the air lock testing is included in anotherSpecification_(ITS_3.6.1.2).

3.6.1.2, PRIMARY CONTAINMENT AIRLOCKS Al Editorial changes, reformatting, and revised numbering.

3.6.1.2 1.O.M, 3.7.A.2, 3.7.A.8, 4.7.A.2.a A2 The CTS reference to "Primary Containment Integrity" has been deleted since the CTS definition of 3.6.1.2 3.7.A.2 Primary Containment Integrity in CTS 1.O.M is incorporated into ITS 3.6.1.1, 3.6.1.2 and 3.6.1.3 and is no longer maintained as a separate definition in the ITS. ITS 3.6.1.2 requires that the primary containment air locks shall beOPERABLE.

A3 The ITS Surveillance that requires leakage rate testing of the air locks includes a Note that states "An SR 3.6.1.2.1 1.0.M, inoperable air lock door does not invalidate the previous successful performance of the overall air lock Note 1 4.7.A.2.a leakage test." This Note is consistent with the CTS 1.0.M Primary Containment Integrity condition requirement that at least one door in each air lock is closed and sealed.

PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS JAFNPP DOC #

SUMMARY

ITS SECTION CTS SECTION A4 Not used.

N/A N/A A5 The ITS includes a Note that requires the applicable Conditions and Required Actions of ITS 3.6.1.1, 3.6.1.2 1.0.M, Primary Containment, to be entered when air lock leakage exceeds the overall Primary Containment ACTIONS Note 4.7.A.2.a leakage rate acceptance criteria. This Note establishes the need to consider the Primary Containment, 3, SR 3.6.1.2.1 OPERABILITY if the air lock leakage acceptance criteria is not being met. This change is consistent with Note 2 the relationship of containment integrity and air lock OPERABILITY established in the CTS definition of Containment Integrity. In addition, the ITS leakage rate test is modified by a Note that states the "Results shall be evaluated against criteria applicable to SR 3.6.1.1.1 ". ITS SR 3.6.1.1.1 is the primary containment leakage rate test and will ensure that air lock leakage is properly accounted for in determining the combined Type B and C primary containment leakage, consistent with the CTS requirements.

3.6.1.3, PRIMARY CONTAINMENT ISOLATION VALVES (PCIV)

Al Editorial changes, reformatting, and revised numbering.

3.6.1.3 1.0.M, Table 4.2-1, 3.7.A.2, 3/4.7.D, 3.7.A.8, 4.7.A.2.b, 4.7.A.2.c, 4.7.B.4 PAGE 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A2 Three Notes have been included in the ITS that are consistent with the intent of the CTS. ITS 3.6.1.3 3.6.1.3 3/4.7.D Note 2, which allows separate Condition entry for each penetration flow path, provides explicit ACTIONS Notes instructions for proper application of the ACTIONS for Technical Specification compliance. In 2, 3, and 4 conjunction with the proposed Specification 1.3, "Completion Times," this Note provides direction consistent with the intent of the existing ACTIONS for inoperable isolation valves. ITS 3.6.1.3 Note 3, to enter applicable Conditions and Required Actions for systems made inoperable by PCIVs, establishes the need to verify individual system OPERABILITY based on the affect of an INOPERABLE PCIV. This requirement is consistent with individual CTS Surveillance Requirements to verify valve OPERABILITY and/or correct position. ITS 3.6.1.3 Note 4, to enter the applicable Conditions and Required Actions of ITS 3.6.1.1, Primary Containment, when PCIV leakage exceeds the overall Primary Containment leakage rate acceptance criteria, establishes the need to consider the Primary Containment OPERABILITY if the PCIV leakage acceptance criteria is not being met. This change is consistent with the relationship of containment integrity and PCIV OPERABILITY established in the CTS 1.0.M definition of Containment Integrity. In addition, Note 4 clarifies that "systems" include the primary containment.

Since proposed LCO 3.0.6 waives the requirement to cascade, the intent of the CTS would not necessarily apply. The clarification provided by the Note is consistent with the intent and interpretation of the existing Technical Specifications.

A3 The CTS requirement, when one PCIV is inoperable, to maintain at least one isolation valve operable in 3.6.1.3 3.7.D.2 each affected penetration that is open, is not explicitly included in the ITS. The ITS is equivalent through Condition B its Conditions and Notes for one and two or more inoperable PCIVs in a penetration.

A4 The CTS requirement, when a PCIV is inoperable, to "restore the inoperable valve(s) to operable status,"

N/A 3.7.D.2.a has been deleted since this is always an option and does not need to be specified in the ITS.

A5 The CTS requirement to record the results of the PCIV position verification is not included in the ITS, N/A 4.7.D.2 since it is duplicative of the requirements of 10 CFR 50 Appendix B,Section XVII (Quality Assurance Records) to maintain records of activities affecting quality, including the results of tests/verifications, and compliance with_10_CFR_50_AppendixB is required by theJAFNPPOperatingLicense.

A6 Not used.

N/A N/A A7 Not used.

N/A N/A JAFNPP PAGE 3

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A8 The ITS provides an exception for reactor building-to-suppression chamber vacuum breakers, in that LCO 3.6.1.3 3.7.D.1 they are not included in the PCIV Specification. Although, reactor building-to-suppression chamber vacuum breakers isolate primary containment penetrations, they are excluded from this specification since reactor building-to-suppression chamber vacuum breakers OPERABILITY requirements are currently specified in another CTS Specification and retained in a separate ITS Specification. Along with this change, the explicit requirement in the CTS that all instrument line excess flow check valves must be Operable has not been specifically stated in the ITS LCO statement, since the valves are considered PCIVs.

A9 The CTS requirement to test PCIVs that are power operated and automatically initiated for simulated SR 3.6.1.3.7 4.7.D.1.a automatic initiation per the IST Program is being revised to more accurately present the requirements as intended. Since the IST Program does not specify the method used to initiate a test for closure timing, the ITS verification that each automatic PCIV actuates to the isolation position on an actual or simulated isolation signal is provided. The Frequency of 24 months has been included consistent with the IST Program and the requirements of CTS Table 4.2-1 (Note 7), Primary Containment Isolation System Instrumentation Test Calibration Requirements.

A10 CTS 4.7.D.1.c, which specifies that all normally open power operated isolation valves (except for the SR 3.6.1.3.5 4.7.D.1.a, main steam isolation valves) shall be fully closed and reopened at a Frequency in accordance with the 4.7.D.1.c IST Program, is encompassed by CTS 4.7.D.1.a. Therefore, the ITS includes a single Surveillance for these two requirements; the redundancy is unnecessary.

Al1 The CTS reference to "Primary Containment Integrity" has been deleted since the CTS definition of 3.6.1.3 3.7.A.2 Primary Containment Integrity in CTS 1.0.M is incorporated into ITS 3.6.1.1, 3.6.1.2 and 3.6.1.3 and is no longer maintained as a separate definition in the ITS. ITS 3.6.1.3 requires that the primary containment isolation valves shall be OPERABLE.

3.6.1.4, DRYWELL PRESSURE NONE NONE NONE NONE PAGE 4 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS

SUMMARY

3.6.1.5, DRYWELL AIR TEMPERATURE NONE NONE NONE NONE 3.6.1.6, REACTOR BUILDING-TO-SUPPRESSION CHAMBER VACUUM BREAKERS Al Editorial changes, reformatting, and revised numbering.

3.6.1.6 3/4.7.A.4, 3.7.A.8 3.6.1.7, SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS Al Editorial changes, reformatting, and revised numbering.

3.6.1.7 3/4.7.A.5, 3.7.A.8 A2 The ITS includes a Note that the vacuum breakers are not required to be closed "when performing their SR 3.6.1.7.1 3/4.7.A.5 intended function," in recognition that the automatic cycling of the vacuum breakers does not violate the Note 2 intent of the CTS LCO.

3.6.1.8, MAIN STEAM LEAKAGE COLLECTION SYSTEM NONE NONE NONE NONE 3.6.1.9, RHR CONTAINMENT SPRAY-SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.6.1.9 3/4.5.B JAFNPP PAGE 5

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A2 The ITS includes the phrase "or can be aligned to the correct position" in recognition that the required SR 3.6.1.9.1 4.5.B.1.e lineup for ECCS OPERABILITY requires the RHR System to be in a lineup other than that necessary to perform the containment spray function and that the containment spray function is manually actuated (requiring repositioning of valves and starting of the RHR pump by the operator), consistent with CTS interpretation and practices.

A3 The CTS Surveillance that requires the pump operability and flow rate test on the RHR pumps SR 3.6.1.9.2 4.5.B.1.a references another CTS Surveillance with respect to the Frequency. The Frequency in the other CTS Specification is in accordance with the Inservice Testing Program. The ITS does not include the cross reference; but includes the actual Frequency (in accordance with the Inservice Testing Program).

A4 The CTS requires the remaining components of the containment cooling mode subsystems to be verified N/A 4.5.B.3 to be operable immediately and daily thereafter when an RHR containment spray component is inoperable. These explicit verifications have all been deleted.

3.6.2.1, SUPPRESSION POOL AVERAGE TEMPERATURE Al Editorial changes, reformatting, and revised numbering.

3.6.2.1 3/4.7.A.1, 3.7.A.8, Table 4.2-8 A2 Not used.

N/A N/A A3 CTS 4.7.A.1 requires the torus temperature to be monitored as specified in CTS Table 4.2-8. The SR 3.6.2.1.1 4.7.A.1, Frequency of the Surveillance in CTS Table 4.2-8 is daily. The ITS does not inc!tidethe cross-reference; Table 4.2-8 but includes the actual Frequency (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />).

A4 During testing that adds heat to the suppression pool, the CTS requires the pool temperature to be N/A 4.7.A.1 continuously recorded until heat is terminated or in lieu of continuously recording, the operator shall log the temperature every 5 minutes.

In the ITS, the continuous recording or logging requirement is not included, since it is duplicative of the requirements of 10 CFR 50 Appendix B,Section XVII (Quality Assurance Records) to maintain records of activities affecting quality, including the results of tests/verifications, and compliance with 10 CFR 50 Appendix B is required by the JAFNPP Operating License._I

_1___

JAFNPP PAGE 6

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A5 The CTS requires the maximum water temperature of the suppression pool to be _< 95°F during normal LCO 3.6.2.1.a 3.7.A.1.c. (1) power operation. The CTS also defines "Reactor Power Operation" to be any operation with the Reactor Mode Switch in the Startup/!Hot Standby or Run position with reactor critical and above 1% rated thermal power. The ITS requires the suppression pool average temperature to be

  • 950F when THERMAL POWER is > 1% RTP and "no testing that adds heat to the suppression pool is being performed." The addition of the words concerning testing (no testing) is considered an administrative change since testing is accounted for in the suppression pool temperature limits in the CTS. The exclusion of the details concerning the Reactor Mode Switch position and whether or not the reactor is critical is also considered to be an administrative change, since the ITS Applicability, the MODES Table, and the requirement that the LCO is applicable when THERMAL POWER is> 1% RTP are sufficient.

3.6.2.2, SUPPRESSIONPOOL WATERLEVEL Al Editorial changes, reformatting, and revised numbering.

3.6.2.2 3/4.7.A.1, 3.7.A.8 A2 CTS 4.7.A.1 requires the torus water level to be monitored as specified in CTS Table 4.2-8. The SR 3.6.2.2.1 4.7.A.1, Frequency of the Surveillance in CTS Table 4.2-8 is daily. The ITS does not include the cross-reference; Table 4.2-8 but includes the actualFrequency_(24_hours).

3.6.2.3, RHRSUPPRESSIONPOOL COOLING Al Editorial changes, reformatting, and revised numbering.

3.6.2.3 3/4.5.B A2 The ITS includes the phrase "or can be aligned to the correct position" in recognition that the required SR 3.6.2.3.1 4.5.B.1.e lineup for ECCS OPERABILITY requires the RHR System to be in a lineup other than that necessary to perform the containment spray function and that the containment cooling function is manually actuated (requiring repositioning of valves and starting of the RHR pump by the operator), consistent with CTS interpretation and practices.

PAGE 7 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A3 The CTS requires the remaining components of the containment cooling mode subsystems to be verified N/A 4.5.B.3 to be operable immediately and daily thereafter when an RHR suppression pool cooling component is inoperable._These explicit verifications have all been deleted.

3.6.2.4, DRYWELL-TO-SUPPRESSION CHAMBER DIFFERENTIAL PRESSURE Al Editorial changes, reformatting, and revised numbering.

3.6.2.4 3/4.7.A.7 A2 The CTS cross-reference to the requirements in Table 4.2-8 are not included since they are redundant to N/A 4.7.A.7.a the normal instrumentation requirements.

3.6.3.1, PRIMARY CONTAINMENT OXYGENCONCENTRATION Al Editorial changes, reformatting, and revised numbering.

3.6.3.1 3/4.7.A.6 A2 The CTS cross-reference to the requirements in Table 4.2-8 are not included since they are redundant to N/A 4.7.A.6.a the normal instrumentation requirements.

3.6.3.2, CAD SYSTEM NONE NONE NONE NONE 3.6.4.1, SECONDARY CONTAINMENT Al1 Editorial changes, reformatting, and revised numbering..

3.6.4.1 1.0.S, 3/4.7.C PAGE 8 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A2 The CTS Applicability is clarified in the ITS (by stating when it is applicable, not when it is not applicable) 3.6.4.1 3.7.C.1 to be MODES 1, 2, and 3, during movement of irradiated fuel assemblies in the secondary containment, Applicability during Core Alterations, and during OPDRVs. In addition, the CTS requirements that CTS 3.3.A, Shutdown Margin be met have been deleted since they are duplicative of the requirements of ITS 3.1.1, SHUTDOWNMARGIN_(SDM).

A3 The CTS Surveillance Requirements to perform preoperational and other tests during the first operating N/A 4.7.C.1.a, cycle are deleted since preoperational testing and the first refueling cycle has already been completed.

4.7.C.1.b A4 The CTS reference to "Secondary Containment Integrity" has been deleted since the CTS definition of LCO 3.6.4.1 3.7.C.1 Secondary Containment Integrity in CTS 1.0.S is incorporated into ITS 3.6.4.1, 3.6.4.2 and 3.6.4.3 and is no longer maintained as a separate definition in the ITS. ITS 3.6.4.1 requires that the secondary containment shall beOPERABLE.

A5 Not used.

N/A N/A 3.6.4.2, SECONDARY CONTAINMENT ISOLATION VALVES Al Editorial changes, reformatting, and revised numbering.

3.6.4.2 1.0.S, Table 4.2-1, 3.7.C, RETS Table 3.10-2 A2 The CTS Applicability is clarified in the ITS (by stating when it is applicable, not when it is not applicable) 3.6.4.2 3.7.C.1 to be MODES 1, 2, and 3, during movement of irradiated fuel assemblies in the secondary containment, Applicability during Core Alterations, and during OPDRVs. In addition, the CTS requirements that CTS 3.3.A, Shutdown Margin be met have been deleted since they are duplicative of the requirements of ITS 3.1.1, SHUTDOWN MARGIN (SDM).

A3 ITS 3.6.4.2 Note 3, to enter applicable Conditions and Required Actions for systems made inoperable by 3.6.4.2 3.7.C SCIVs, establishes the need to verify individual system OPERABILITY based on the affect of an ACTIONS Note INOPERABLE SCIV. This requirement is consistent with individual CTS Surveillance Requirements to 3

verify valveOPERABILITY and/or correct position._I_

I JAFNPP PAGE 9

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A4 The CTS reference to "Secondary Containment Integrity" has been deleted since the CTS definition of LCO 3.6.4.2 3.7.C.1 Secondary Containment Integrity in CTS 1.0.S is incorporated into ITS 3.6.4.1, 3.6.4.2 and 3.6.4.3 and is no longer maintained as a separate definition in the ITS. ITS 3.6.4.2 requires that the secondary containment isolation valves shall beOPERABLE.

A5 Not used.

N/A N/A A6 The detail in the RETS identifying how the Logic System Functional Test (LSFT) is to be performed (i.e.,

LSFT definition RETS Table where possible using test jacks) has not been included in the ITS since the definition of LSFT provides 3.10-2 Note f the necessary guidance.

3.6.4.3, STANDBY GAS TREATMENT SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.6.4.3 1.0.3, 3/4.7.B, 3.7.C, Table 4.2-1, RETS Table 3.10-2 A2 The CTS requirements for ventilation filter testing are moved to ITS 5.5.8 "Ventilation Filter Testing SR 3.6.4.3.2, 4.7.B.1.a, Program (VFTP)". ITS SR 3.6.4.3.2 requires that the SGT filter testing be performed in accordance with 5.5.8 4.7.B.1.b, the Ventilation Filter Testing Program to determine the Operability of the SGT System.

4.7.B.1.c A3 The CTS Applicability is clarified in the ITS (by stating when it is applicable, not when it is not applicable) 3.6.4.3 3.7.B.1, to be MODES 1, 2, and 3, during movement of irradiated fuel assemblies in the secondary containment, Applicability 3.7.C.1 during Core Alterations, and during OPDRVs. In addition, the CTS requirements that CTS 3.3.A, Shutdown Margin be met have been deleted since they are duplicative of the requirements of ITS 3.1.1, SHUTDOWN MARGIN (SDM).

A4 The CTS requires manual operability of the bypass valve for Standby Gas Treatment (SGT) subsystem SR 3.6.4.3.4 4.7.B.1.e filter cooling to be demonstrated (for each subsystem). The ITS requires cycling of each SGT subsystem filter cooling cross-tie valve (cooler bypass valve), consistent with the current practice and interpretation.

A5 The CTS requires the redundant SGT subsystem to be verified to be operable immediately and daily N/A 4.7.B.2 thereafter when anSGT subsystem is inoperable._This explicit verification has been deleted.

PAGE 10 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS JAFNPP DOC #

SUMMARY

ITS SECTION CTS SECTION A6 The detail in the RETS identifying how the Logic System Functional Test (LSFT) is to be performed (i.e.,

LSFT definition RETS Table where possible using test jacks) has not been included in the ITS since the definition of LSFT provides 3.10-2 Note f the necessary guidance.

CTS 3.7.A.3, CONTAINMENT PURGE THROUGH THE STANDBY GAS TREATMENT SYSTEM NONE NONE NONE NONE PAGE 11

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS

SUMMARY

3.7.1 RHRSW SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.7.1 3/4.5.B A2 The CTS footnote that provides an additional 4 days to operate with an inoperable RHRSW subsystem N/A 3.5.B.3 during the installation of modification 00-125 has not been included in the ITS since the modification is footnote

  • complete.

3.7.2, ESWSYSTEM andUHS Al Editorial changes, reformatting, and revised numbering.

3.7.2 3/4.11.D, 3/4.11..E A2 The CTS allows 7 days of operation with one Emergency Service Water (ESW) System inoperable. The 3.7.2 Required 3.11.D.2 ITS includes a Note that would require the applicable Conditions and Required Actions of ITS 3.8.1, "AC Action A.1 Note Sources -

Operating, "to be entered for the Emergency Diesel Generator (EDG) subsystem made inoperable by ESW. This Note is an exception to proposed LCO 3.0.6 which ensures proper ACTIONS are taken for an inoperable EDG subsystem. This Note is consistent with the current requirements, since the CTS only allows 7 days of operation if the operable Emergency Diesel Generator System is demonstrated to be operable immediately and daily thereafter.

A3 The ESW instrumentation surveillance requirements have been moved to ITS 3.3.7.3, "Emergency 3.3.7.3 4.11.D.l.e, Service Water (ESW) System Instrumentation".

4.11.D.1.f A4 The CTS requirements for intake deicing heaters have been included with the requirements of ESW and 3.7.2 3/4.11.E the Ultimate Heat Sink (UHS), since the intake deicing heaters help to ensure adequate flow to the ESW and Residual Heat Removal System.

A5 The CTS requires the intake deicing heaters to be Operable when intake water temperature is less than 3.7.2 3.11.E or equal to 37°F. When these heaters are inoperable the default action is to be in the cold condition Applicability, (MODE 4). In the ITS, the Applicability of the deicing heaters is MODE 1, 2 and 3, consistent with the SR 3.7.2.3, SR requirements of the ESW System. In addition, the ITS includes a Note in the applicable surveillances 3.7.2.5, SR related to the heaters that these SRs are not required to be met at lake temperatures > 37°F.

3.7.2.6 JAFNPP PAGE 1

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A6 The CTS requires the weekly verification of the six heater feeder ammeters. The ITS requires the SR 3.7.2.3 4.11.E.1 verification of the "required" deicing heater feeder current for each division of deicing heaters. Since the CTS only requires 18 out of 88 heaters to be OPERABLE (modified by DOC M3), there is no reason to require the measurement of all heater feeder ammeters.

A7 The CTS requires a valve alignment check every 31 days. The ITS includes a Note that clarifies that the SR 3.7.2.4 4.11.D.1.c isolation of flow to an individual component does not necessarily render the ESW System inoperable; Note only the individual component is considered inoperable. This is consistent with current practice and the intent of the CTS.

A8 The CTS requirements to monitor the individual heater current once every 6 months has been changed SR 3.7.2.5 4.11.E.2 to require the verification of the required deicing heater power, consistent with current practice and the intent of the CTS.

3.7.3, CREVAS SYSTEM Al Editorial changes, reformatting, and revised numbering.

3.7.3 3/4.11.A A2 The specific CTS requirements for the periodic verification of the filter trains associated with the Control SR 3.7.3.2, 4.11.A.1.a, Room Emergency Ventilation Air Supply (CREVAS) System have been moved to ITS 5.5.8, the 5.5.8 4.11.A.1.b, Ventilation Filter Testing Program (VFTP). This ITS Specification will include a Surveillance that will 4.11.A.1.c, require performing CREVAS System filter testing in accordance with the VFTP.

4.11.A.2 3.7.4, CONTROL ROOM AC SYSTEMNONENONE NONE INONE NONE NONE PAGE 2 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS

SUMMARY

12 7 r,

KhA KI Err' r)KinpKjD pt--TIF:AM.IIT AlPIR EJEC'TOR FF(GAS Al Editorial changes, reformatting, and revised numbering.

3.7.5 RETS 3.5, RETS Tables 3.10-1 and 3.10-2 A2 The RETS specifies the limitations and surveillance requirements for gross radioactivity (beta and/or LCO 3.7.5, SR RETS 3.5.a gamma) rate of noble gases. The ITS only places limitations on the gross gamma activity rate of the 3.7.5.1 (LCO and SR noble gases instead of "beta and/or gamma". The option to measure the beta rate of activity has been sections) deleted sinceJAFNPP utilizes the gross gamma approach which is consistent with industry practice.

3.7.6, MAIN TURBINE BYPASS SYSTEM NONE NONE NONE NONE 3.7.7, SPENT FUEL STORAGE POOL WATER LEVEL Al Editorial changes, reformatting, and revised numbering.

3.7.7 3/4.10.C CTS 3/4.8, MISCELLANEOUS RADIOACTIVE MATERIALS SOURCES NONE NONE NONE NONE CTS 3/4.11.C, BATTERY ROOM VENTILATION NONE NO)NEF NONE INONE PAGE 3 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.8.1, AC SOURCES - OPERATING Al Editorial changes, reformatting, and revised numbering.

3.8.1 3.9.A, 3/4.9.B, 3/4.9.C.2, 3.0.E A2 The CTS specifies the conditions under which the EDG system is required will be simulated to SR 3.8.1.12 4.9.B.4 demonstrate that the pair of diesel generators will start, accelerate, force parallel and accept the emergency loads in the prescribed sequence. The ITS is clarified to require verification that the diesel generator, in response to loss of power signal in conjunction with an ECCS initiation signal will auto-start from a standby condition and energize as required permanently connected loads within the required time and auto-connected emergency loads in the prescribed sequence.

A3 The CTS monthly requirement to start, accelerate, force parallel and load each pair of EDGs and run until SR 3.8.1.2, SR 4.9.B.1 both EDGs are at steady state temperature conditions has been divided into two separate Surveillance 3.8.1.3 including Requirements; a start test and a load test. In addition, due to this splitting, the ITS includes a Note to Note 4 clarify the requirement that the load test must be preceded by and immediately follow, without shutdown, a successful start test.

A4 The CTS requires that the paralleled EDG pair be loaded until both EDGs are at steady state temperature SR 3.8.1.3 4.9.B.1 conditions. The ITS requires that the loaded EDG pair be run for Ž 60 minutes, since this is the minimum run time to stabilize engine temperatures.

A5 The CTS includes a LCO statement related to the Diesel Fuel Oil Transfer System OPERABILITY. The LCO 3.8.1 3.9.C.2 ITS does not include a specific LCO statement, as it is part of the AC Sources LCO statement, and is ensured by an ITS Surveillance Requirement.

A6 The CTS does not provide specific Actions for the condition of three or more AC sources inoperable and 3.8.1 ACTION G 3.9.B therefore entry into CTS 3.0.C is required. Since the ITS format allows multiple Conditions to be entered simultaneously, with three or more AC sources inoperable, ACTIONS would be taken in accordance with ITS 3.8.1, and ITS LCO 3.0.3 entry conditions would not be met. However, consistent with the CTS default to CTS 3.0.C, ITS 3.8.1 ACTION G will require direct entry into ITS LCO 3.0.3.

A7 The wording in the CTS related to the criteria for determining whether a potential common cause EDG 3.8.1 Required 4.9.B.5.a, failure exists is editorially changed in the ITS to require a determination of whether the other Operable Action B.3.1 4.9.B.5.b, EDG and EDG subsystems are not inoperable due to common cause failure.

4.9.B.5.c PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION A8 The ITS includes a Note in certain EDG Surveillances to allow all EDG subsystem starts to be preceded SR 3.8.1.2, SR 4.9.B.1, 4.9.B.4 by an engine prelube period to minimize wear and tear on the EDGs during testing. This is consistent 3.8.1.9, SR with the CTS since the EDGs at JAFNPP are not immediately loaded upon startup and run in a 3.8.1.10, SR continuous prelube mode of operation. In addition, the Note to ITS SR 3.8.1.2 also allows a warmup 3.8.1.12 period prior to loading. This is consistent with current practices since the EDGs are not immediately loaded upon startup, but are allowed to warmup for a short time after startup while the operation staff performs post startup EDG checks.

A9 The CTS provides an allowance that the 7 day allowed outage time for a single offsite circuit can be N/A CTS 3.9.B.1 extended to 14 days (for line #3 and associated transformer only) during the period from 9/9/01 through footnote*

9/23/01. Since the time period has been exceeded, this allowance is not applicable anymore, and is not included in the ITS_1_

1 3.8.2, ACSOURCES -_SHUTDOWN Al Editorial changes, reformatting, and revised numbering.

3.8.2 3.9.D A2 The CTS requirement for one offsite power source and one Emergency Diesel Generator (EDG)

LCO 3.8.2 and 3.9.D subsystem OPERABLE, whenever any work is being done which has the potential for draining the vessel, Applicability secondary containment is required, or core or containment cooling is required is editorially changed in the ITS to require the AC power sources to be OPERABLE when required to support ITS LCO 3.8.8, "Distribution Systems -

Shutdown". Actual changes to the requirements are discussed elsewhere.

A3 The ITS includes a Note that requires the applicable Condition and Required Actions of ITS LCO 3.8.8, 3.8.2 Required Definition of "Distribution Systems -

Shutdown" be entered when any required division is de-energized as a result of Action A Note Operability Condition A. While the CTS does not explicitly require this in this Specification, this is consistent with the requirements of the CTS (definition of Operability)._II 3.8.3, DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR Al Editorial changes, reformatting, and revised numbering.

3.8.3 3/4.9.C.1, 3.9.C.3, 4.9.B.2 JAFNPP PAGE 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS

SUMMARY

ITS SECTION CTS SECTION Consistent with the CTS, the ITS includes a Note that specifically allows separate Condition entry for 3.8.3 ACTIONS 3.9.C.3 each EDG. In conjunction with ITS Section 1.3, Completion Times, this Note provides explicit instructions Note for proper application of the new Specification. It is intended that each Required Action be applied separately for each affected EDG regardless of whether it had been applied previously for inoperable diesel fuel oil, lube oil or starting air functions.

3.8.4. DC SOURCES - OPERATING Al Editorial changes, reformatting, and revised numbering.

3.8.4 3/4.9.E, 3/4.9.F A2 The CTS requirement that operations may continue only if the other battery including its battery charger is N/A 3.9.E.2.a Operable has not been included in the ITS, since the ITS requires the Division 1 and 2 125 VDC electrical power subsystems to be Operable, the ITS Bases specifies that this consists of both a battery and a charger, and there is no other ITS Condition that allows operation to continue with two 125 VDC electrical power subsystems.

A3 When one LPCI MOV independent power supply becomes unavailable, the CTS allows 7 days of 3.8.4 ACTION C 3.9.F.2 operation consistent with the actions in CTS 3.5.A.2 for an inoperable LPCI subsystem. Since a LPCI MOV independent power supply subsystem is a support system for a LPCI subsystem, the ITS action is to "Declare the associated LPCI subsystem inoperable."

A4 The CTS requirement to be in cold shutdown within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if both station batteries are found to be LCO 3.0.3 3.9.E.3 inoperable is not retained as a specific action in the AC Sources - Operating Specification. In the ITS, entry into 3.0.3 will be required. Since the actions required by CTS 3.0.C are the same as the CTS actions stated above, this change is considered administrative (see ITS Chapter 3.0 DOCs for changes to CTS 3.0.C).

A5 For clarity and consistency, the CTS term "in service", when referring to the state of the DC Sources, has LCO 3.8.4 3.9.E.1, 3.9.F.1 been replaced in the ITS with the term "OPERABLE."

3.8.5, DC SOURCES - SHUTDOWN NONE NONE NONE NONE JAFNPP PAGE 3

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.8.6, BATTERY CELL PARAMETERS Al Editorial changes, reformatting, and revised numbering.

3.8.6 3.9.E.1, 3.9.F.1, 4.9.E.1, 4.9.E.2, 4.9.F.1, 4.9.F.2 A2 The CTS includes the battery cell parameters as attributes of the DC Sources. In the ITS, a specific LCO LCO 3.8.6 3.9.E.1, 3.9.F.1 statement is provided for the battery cell parameters.

A3 The CTS requires the voltage of each cell to be measured to nearest 0.01 V. The ITS is clarified to Table 3.8.6-1 4.9.E.2.a, include the actual float voltage requirements in Table 3.8.6-1 (i.e. 2.13 V and 2.07 V), which is specified 4.9.F.2.a at a level of measurement tolerance corresponding to 0.01 V.

A4 Consistent with the CTS, the ITS includes a Note that specifically allows separate Condition entry for 3.8.6 ACTIONS 3.9.E, 3.9.F each battery. In conjunction with ITS Section 1.3, Completion Times, this Note provides explicit Note instructions for proper application of the new Specification. It is intended that each Required Action be applied separately for each affected battery regardless of whether it had been applied previously for inoperable battery cell parameters.

3.8.7, DISTRIBUTION SYSTEMS - OPERATING Al Editorial changes, reformatting, and revised numbering.

3.8.7 3.9.A, 3.9.E A2 For clarity and consistency, the CTS terms "in service" and "energized", when referring to the state of the LCO 3.8.7 3.9.A2, 3.9.E.1 DC Sources, have been replaced in the ITS with the term "OPERABLE."

A3 The ITS includes a new ACTION for the loss of AC buses and for loss of 125 VDC buses requiring entry 3.8.7 ACTION D 3.0.C into LCO 3.0.3 if two or more electrical power distribution subsystems are inoperable that result in a loss of function. This is consistent with the CTS, since any AC or DC electrical power distribution subsystem inoperability currently requires entry into CTS LCO 3.0.C.

PAGE 4 JAFNPP

DOC #

17!d NONE JAFNPP TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS

SUMMARY

ITS SECTION CTS SECTION 3.8.8, DISTRIBUTION SYSTEMS - SHUTDOWN INONE NONE PAGE 5

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.9 - REFUELING OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.9.1, REFUELINGEQUIPMENTINTERLOCKS Al Editorial changes, reformatting, and revised numbering.

3.9.1 3/4.10.A A2 CTS is proposed to be broken into two parts: ITS 3.9.1, "Refueling Equipment Interlocks" which covers 3.9.1 3/4.10.A in-vessel fuel movement only, with the reactor mode switch in refuel; and, ITS 3.9.2, "Refuel Position One-Rod-Out Interlock" which covers control rod withdrawal during MODE 5.

A3 The CTS is applicable "during Core Alterations" but then modifies this with the statement "except as N/A 3.10.A.1 specified in 3.10.A.5, 3.10.A.6, 3.10.A.7 and 3.10.D below." In the ITS, this cross reference to other Specifications is not included in the Applicability statement.

A4 The CTS requires the hoist load switch on the service platform hoist to be set at less than or equal to 400 N/A 3.1 0.A.4 lbs whenever it is to be used for handling fuel. This requirement is not incorporated in the ITS, since the service platform is no longer utilized at JAFNPP. In fact the service platform has been removed from the plant and any discussion of the service platform, or associated hoist has been eliminated from UFSAR, Section 7.6 which discusses the refueling interlocks.

3.9.2, REFUEL POSITIONONE-ROD-OUTINTERLOCK Al Editorial changes, reformatting, and revised numbering.

3.9.2 3/4.10.A A2 CTS is proposed to be broken into two parts: ITS 3.9.1, "Refueling Equipment Interlocks" which covers 3.9.2 3/4.10.A in-vessel fuel movement only, with the reactor mode switch in refuel; and, ITS 3.9.2, "Refuel Position One-Rod-Out Interlock" which covers control rod withdrawal during MODE 5.

A3 The CTS is applicable "during Core Alterations" but then modifies this with the statement "except as N/A 3.10.A.1 specified in 3.10.A.5, 3.10.A.6, 3.10.A.7 and 3.10.D below." In the ITS, this cross reference to other Specifications is not included in the Applicability statement.

3.9.3, CONTROL ROD POSITION Al Editorial changes, reformatting and revised numberin.

3.9.3 3.10.A.2 PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.9 - REFUELING OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION A2 The CTS requires that fuel not be loaded into the reactor core unless all control rods are fully inserted.

3.9.3 ACTION A 3.1O.A.2 Implicit in this requirement is that, if all control rods are not fully inserted, action must be immediately taken to suspend loading of fuel assemblies into the core. In the ITS, an ACTION is added to explicitly require immediate suspension of loading of fuel assemblies into the core in the event that one or more control rods are not fully inserted.

3.9.4, CONTROL ROD POSITION INDICATION NONE NONE NONE NONE 3.9.5, CONTROL ROD OPERABILITY - REFUELING NONE NONE NONE NONE 3.9.6, REACTOR PRESSURE VESSEL WATER LEVEL NONE NONE NONE NONE 3.9.7, RESIDUAL HEAT REMOVAL - HIGH WATER LEVEL NONE NONE NONE NONE 3.9.8, RESIDUAL HEAT REMOVAL - LOW WATER LEVEL NONE NONE NONE NONE JAFNPP PAGE 2

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.10 - SPECIAL OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.10.1, INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION Al Editorial chang1es, reformatting, and revised numbering.

3.10.1 3/4.12.A A2 The cross references to LCO 3.5.F, "ECCS -

Cold Shutdown", and LCO 3.9, "Auxiliary Electrical N/A 3.12.A.1, Systems", respectively have been deleted. The requirements of these Specifications will be normally 3.12.A.5 required in MODE 4 in the associated applicable Specifications of ITS Sections 3.5 and 3.8, therefore the cross references to these Specifications is not necessary.

A3 The ITS includes a clarification to permit the suspension of the requirements of ITS 3.4.8, "Residual Heat LCO 3.10.1 3.12.A Removal (RHR) Shutdown Cooling -

Cold Shutdown." In addition, the ITS includes a clarification to change the temperature specified in Table 1.1-1 for MODE 4 to "NA". These clarifications have been made to clearly define the allowances of the proposed Specification, consistent with current practice and interpretation of the CTS.

A4 The CTS allows the reactor to be considered to be in COLD SHUTDOWN with reactor coolant LCO 3.10.1 3.12.A temperature between 212°F and 3000 F. The Applicability of the ITS is MODE 4 with average reactor coolant temperature > 212°F (the limit of 300°F has been relocated to the Technical Requirements Manual (TRM) in accordance with DOC LA1). Thus the ITS uses the inequality sign in lieu of the term "between."

3.10.2, REACTOR MODE SWITCH INTERLOCK TESTING NONE NONE INONE NONE 3.10.3, SINGLE CONTROL ROD WITHDRAWAL - HOT SHUTDOWN NONE NONE NONE NONE 3.10.4, SINGLE CONTROL ROD WITHDRAWAL - COLD SHUTDOWN NONE NONE NONE NONE JAFNPP PAGE 1

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.10 - SPECIAL OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.10.5, SINGLE CONTROL ROD DRIVE REMOVAL - REFUELING Al Editorial changes, reformatting, and revised numbering.

3.10.5 3/4.10.D A2 The CTS provides restrictions on control rod and control rod drive maintenance. The ITS includes a 3.10.5.d 3.10.D restriction on all other CORE ALTERATIONS during the performance of this Special Operations LCO.

This addition is considered administrative since CORE ALTERATIONS are addressed in CTS 3.10 (CTS 3.10.A.2 prohibits any fuel loading operations since all other control rods must be fully inserted unless loading in accordance with a spiral on-load. Since the spiral on-load allows refueling interlocks to be bypassed only in those cells which contain no fuel, fuel loading operations are not permitted when the plant is operating within CTS 3.10.D).

A3 The CTS includes cross references to other requirements concerning the removal of more than two N/A 3.10.D.2, control rods. These cross references are not included in the ITS since they are redundant to other LCOs.

4.10.D.2 A4 The CTS allows two control rods to be withdrawn from the reactor core to perform maintenance.

3.10.5 3.10.D Therefore, since maintenance is allowed to be performed, the withdrawn control rods may not be Applicability Operable. In the ITS, this is covered by the Applicability, which is MODE 5 with LCO 3.9.5 not met.

3.10.6, MULTIPLE CONTROL ROD WITHDRAWAL - REFUELING Al Editorial changes, reformatting, and revised numbering.

3.10.6 3/4.10.A.2, 3.1 0.A.5, 3.1 0.A.6, 3.1 0.A.7 A2 The ITS includes an ACTION to 1) suspend withdrawal/removal of the control rod and removal of the 3.10.6 ACTION 3/4.10.A.2, CRD, 2) suspend loading of fuel assemblies, and 3) initiate action to insert all control rods in core cells A

3.10.A.5, containing fuel, or to satisfy the requirements of the LCO. The CTS only implies these actions (the control 3.1 0.A.6, rods and CRDs can only be removed if the LCO requirements are met).

I

_1_3.1 0.A.7 PAGE 2 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.10- SPECIAL OPERATIONS PAGE 3 JAFNPP CTS SECTION ITS SECTION

SUMMARY

DOC #

A3 CTS 3.10.A.5.d requires fuel on-loading operations to be suspended until CTS 3.10.A.2 is satisfied. The LCO 3.10.6.c, 3.10.A.5.d requirement of CTS 3.10.A.2 is that fuel loading can commence if all control rods are fully inserted except LCO 3.9.3 as permitted by CTS 3.10.A.7. CTS 3.10.A.7 specifies the requirements of a spiral on-load. These cross references are not included in the ITS since the requirements of CTS 3.10.A.7 (spiral on-loading) have been incorporated directly in this ITS LCO and the refueling requirement of CTS 3.10.A.2 (fuel loading can commence if all control rods are fully inserted) is incorporated into ITS 3.9.3.

A4 The CTS requires the fuel assemblies, situated in the control cell of the control rod to be withdrawn, to be LCO 3.10.6.b 3.10Q.A.5.b removed. This implies all other control rods are inserted since they would not be allowed to be withdrawn if operating under this LCO. For clarity, the ITS includes an explicit requirement that all other control rods in core cells containing one or more fuel assemblies be fully inserted.

A5 The CTS requires the verification that the control cell contains no fuel before the corresponding control LCO 3.10.6.a, 4.10.A.2 rod is withdrawn whenever the reactor mode switch is in the refuel position and refueling interlocks are SR 3.10.6.1 bypassed. This allowance is included in both the ITS LCO and a Surveillance Requirement.

A6 The ITS adds an explicit Applicability, consistent with the intent of the CTS. This Applicability is MODE 5 3.10.6 3/4.10.A.2, with LCO 3.9.3, LCO 3.9.4, and LCO 3.9.5 not met. LCO 3.9.3, "Control Rod Position" requires all rods to Applicability 3.10.A.5, be fully inserted. LCO 3.9.4, "Control Rod Position Indication" requires each control rod "full-in" position 3.1 0.A.6, indication channel to be OPERABLE. LCO 3.9.5, "Control Rod OPERABILITY"-- Refueling" requires 3.10.A.7 each withdrawn control rod to be OPERABLE. During multiple control rod withdrawals these requirements can not be met for those rods which are to be withdrawn.

3.10.7, CONTROL ROD TESTING - OPERATING NONE NONE NONE NONE I

I I

TABLE A - ADMINISTRATIVE CHANGES MATRIX SECTION 3.10 - SPECIAL OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.10.8, SHUTDOWN MARGIN TEST - REFUELING Al Editorial changes, reformatting, and revised numbering.

3.10.8 3.6.E.3, Table 3.1-1,3.5.B.5, 3.2.A, Table 3.2-1, 3.7.A.2, 3.7.A.4.a, 3.7.A.5.a, 3.7.D.1 A2 The explicit allowances in the CTS to allow S/RVs and components of the Containment Cooling Mode of 3.4.3 3.6.E.3, 3.5.B.5 the RHR System to be inoperable have been deleted since these allowances are permitted implicitly in Applicability, the proposed Applicability of ITS 3.4.3 (for S/RVs), ITS 3.6.1.9 (for RHR Containment Spray), and 3.6.2.3 3.6.1.9 (for RHR Suppression Pool Cooling) and 3.7.1 (for RHR Service Water), and ITS 3.10.8.

Applicability, 3.6.2.3 Applicability, 3.7.1 Applicability, 3.10.8 A3 The CTS provides an allowance that the provisions of CTS 3.0.D are not applicable when an S/RV is N/A 3.6.E.4 inoperable. The intent of this allowance was to allow the Safety/Relief Valves to be inoperable and allow entry into the low power physics testing or reactor operator training as allowed by the CTS. This explicit allowance has not been included in the ITS, as it is not necessary (CTS 3.0.D is only applicable when changing into modes of operation where the S/RVs are required to be Operable, and, in the case of the S/RVs, they are not required to be Operable during the specified conditions, therefore the explicit allowance is not required.)

A4 The requirements of CTS Table 3.1-1 for APRM Neutron Flux-Startup and APRM Inoperative have been LCO 3.10.8.a, Table 3.1-1 moved to ITS LCO 3.10.8.a (ITS LCO 3.3.1.1, "Reactor Protection System Instrumentation", MODE 2 SR 3.10.8.1 Trip Functions requirements for Function 2.a and 2.d of Table 3.3.1.1-1). This change is consistent with the APRM Neutron modifications as discussed in the Discussion of Changes for ITS 3.3.1.1. In addition, the Surveillances Flux-Startup required for these instruments have also been included in ITS 3.10.8.

and Fixed High Neutron Flux, including Note 7 JAFNPP PAGE 4

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 4.0 - DESIGN FEATURES DOC #

SUMMARY

ITS SECTION CTS SECTION Al Editorial changes, reformatting, and revised numbering.

4.0 5.0, RETS 1.0.L, RETS Figure 5.1-1 A2 Not used.

N/A N/A A3 The CTS allows use of fuel assemblies of designs that are approved by the NRC. In lieu of this, the ITS 4.2.1 5.2.1 provides additional description of the various types of fuel designs (fuel assemblies with water rods, zirconium filler rods or stainless steel filler rods) allowed to be loaded in the core.

A4 The CTS states that the types of metal used in the control rods is described in UFSAR Section 3.4. In 4.2.2 5.2.2 lieu of this reference, the ITS states that the control material shall be boron carbide or hafnium as approved by the NRC. This change provides clarifying information regarding the types of metal used in control rods, consistent with the UFSAR description.

A5 Not used.

N/A N/A A6 The CTS states that the nominal center to center distance between fuel assemblies placed in the storage 4.3.1.1.c 5.5.1.1.c racks are in accordance with the requirements of UFSAR Section 9.3. In lieu of this reference, the ITS provides the additional information referenced in UFSAR Section 9.3 for the two different storage rack types and dimensions.

I______

I____________

JAFNPP PAGE 1

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS

SUMMARY

5.1. RESPOlNSIBILITY Al Editorial changes, reformatting, and revised numbering.

5.1 6.0, 6.1, RETS 7.1 A2 The details of CTS 6.0, "Administrative Controls," which describe the content and use of the succeeding N/A 6.0 Specifications are being deleted, since the Administrative Controls are adequately covered by the subsequent ITS Specifications that are retained.

A3 The CTS title "Site Executive Officer" and RETS title "Resident Manager" are revised in the ITS by 5.1.1 6.1, RETS replacing plant specific management titles with generic titles as generally provided in ANSI N18.1-1971.

7Property "ANSI code" (as page type) with input value "ANSI N18.1-1971.</br></br>7" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..1.a A4 The CTS statement that the Site Executive Officer is responsible for safe operation of the plant is 5.1.1 6.1 revised. The ITS states that the plant manager (as modified by DOC A3) shall be responsible for overall plant operation,_and establishes the requirement to designate,_in writing,_a successor.

5.2, ORGANIZATION Al Editorial changes, reformatting, and revised numbering.

5.2 6.2, Table 6.2 1, 6.3.2, 6.3.3, RETS 7.1.b A2 Various CTS titles/terms are revised in the ITS by replacing plant specific management/personnel titles 5.2 6.2, Table 6.2 with generic titles as generally provided in ANSI N18.1-1971 and specifying the location of 1

documentation is provided in the UFSAR. The specific replacements are: a) plant manager for Site Executive Officer, b) chief nuclear officer for Chief Nuclear Officer, c) radiation protection for Health Physics, d) radiation protection technician for an individual qualified in radiation protection procedures, e) operations manager for Operations Manager, and f) assistant operations manager for Assistant Operations Manager.

A3 The responsibilities of the chief nuclear officer in the CTS are revised in the ITS to clarify that this 5.2.1.c 6.2.1.3 individual_"shall have corporate responsibility for overall plant nuclear safety."

PAGE 1 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION A4 The CTS statement that the Site Executive Officer is responsible for overall plant operation is editorially 5.2.1.b 6.2.1.2 revised in the ITS to state that the plant manager (as modified by DOC A2) shall be responsible for overall safe operation of the plant.

A5 The CTS requirements that the STA be on site, and permits the STA position to be combined with one of N/A Table 6.2-1, the SRO positions, provided the individual meets the dual role SRO/STA qualification requirements are including not included in the ITS since these issues are adequately addressed in the "Commission Policy footnote

  • Statement on Engineering Expertise on Shift," published in the October 28, 1985 Federal Register (50 FR_43621).

A6 The CTS requires an SRO or an SRO with a license limited to fuel handling to directly supervise all N/A 6.2.2.2 CORE ALTERATIONS. This requirement is adequately addressed in 10 CFR 50.54(m)(2)(iv), and need not be repeated in theITS.

A7 The CTS requires that the Shift Manager and Control Room Supervisor hold an SRO license and that the N/A 6.2.2.5 Senior Nuclear Operator and the Nuclear Control Operator hold an SRO or an RO license. Operator licensing requirements for these positions are adequately addressed in 10 CFR 50.54(l) and 10 CFR 55.2, and need not be repeated in the ITS.

A8 The CTS requirement concerning the STA qualifications is editorially revised in the ITS to clarify that the 5.2.2.f 6.3.2 STA provide advisory technical support to the shift supervisor in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to the safe operation of the plant, consistent with the guidance provided in NUREG-0737, the Commission Policy Statement on Engineering Expertise on Shift, and NRC Information Notice 93-8.

A9 The CTS requires that the STA meet the requirements of either Option 1 (combined SRO/STA position)

N/A 6.3.2 or Option 2 (continued use of STA position); and that, when invoking Option 1, the STA role may be filled by the Shift Manager or the Control Room Supervisor. These details are adequately addressed in the "Commission Policy Statement on Engineering Expertise on Shift," and need not be repeated in the ITS.

A10 The CTS requires that any qualification deviations will be justified to the NRC prior to an individual's N/A 6.3.3 filling of one of the identified positions. This requirement is adequately addressed in the federal regulations_(e.g.,_10_CFR_50.54,_10_CFR_50.120)_and need not be repeated in theITS.

PAGE 2 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS

SUMMARY

5.3. PLANT STAFF QUALIFICATIONS Al Editorial changes, reformatting, and revised numbering.

5.3 6.3.1 A2 Not used.

N/A N/A A3 The CTS reference to staff positions shown in FSAR Figure 13.2-7 (Plant Staff Organization) has been N/A 6.3.1 deleted. The ITS retains the requirement for staff qualifications of ANSI N18.1-1971 but does not require the identification of the location of the plant organization chart.

A4 The ITS includes clarification that the minimum staffing requirements stipulated in 10 CFR 50.54(m) for 5.3.2 N/A personnel actively performing the functions of licensed Senior Reactor Operators (SROs) and Reactor Operators (ROs), can be exceeded without requiring a license amendment provided the SRO or RO functions and duties are divided and rotated in a manner which provided each SRO or RO with meaningful and significant opportunity to maintain proficiency.

5.4, PROCEDURES Al Editorial changes, reformatting, and revised numbering.

5.4 6.8, RETS 7.2 A2 The CTS requires that written procedures be implemented for programs specified in Appendix B, N/A 6.8.(A).4 Radiological Effluent Technical Specifications (RETS), Section 7.2. This specification is not retained in the ITS because the specific programs specified in RETS 7.2 are retained in ITS 5.4.1.c and 5.4.1.e.

A3 The RETS requires procedures be implemented for the Process Control Program (PCP). The PCP N/A RETS 7.2 implements the requirements of 10 CFR 20, 10 CFR 61, and 10 CFR 71. Since these types of procedures are also required by the CTS, which references Regulatory Guide 1.33, and are retained by the ITS, it is not necessary to specifically identify them again in the ITS.__

PAGE 3 I___

.II JAFNPP

TABLE A - ADMINISTRATIVE CHANGESWMATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS

SUMMARY

5.5 PROG(RAMS AND MANUALS Al Editorial changes, reformatting, and revised numbering.

5.5 Facility Operating License 2.C(4), 1.0.T, 4.0.E, 4.7.B.1.a, 4.7.B.1.b, 4.7.B.1.c, 4.11.A.1, 4.11.A.2, 6.10.(B).6, Table 6.10-1, 6.17,6.19, 6.20, 6.21, 6.22, RETS 1.0.H, RETS 2.5 A2 The CTS programmatic requirements for the Offsite Dose Calculation Manual (ODCM) have been 5.5.1 6.17 editorially revised in the ITS.

A3 Not used.

N/A N/A A4 Not used.

N/A N/A A5 CTS 6.20.0, which states that Specification 4.0.B is not applicable to the Primary Containment Leakage 5.5.6.e 6.20.D Rate Testing Program is not retained in the ITS since ITS Section 3.0/4.0 do not apply to the Administrative Controls Section unless otherwise stated. In addition, for clarity, the ITS includes a reference to the prohibition of the modification of the testing Frequencies required by 10 CFR 50, AppendixJ.

JAFNPP F-I Ia%-Al IýIVIý PAGE 4

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS PAGE 5 DOC #

SUMMARY

ITS SECTION CTS SECTION A6 ITS 5.5.4, "Radioactive Effluent Controls Program" has been added. ITS 5.5.4 establishes 5.5.4 N/A programmatic controls to ensure compliance with applicable regulatory requirements. The program captures the existing requirements for control of radioactive effluents contained in the CTS Radiological Environmental Technical Specifications (RETS), which are proposed to be removed and relocated, consistent with Generic Letter 89-01, to the ODCM (see RETS DOCs).

A7 The CTS requires that inservice testing (IST) of pumps and valves be performed in accordance with N/A 4.0.E.1,Section XI of the ASME Code and applicable Addenda as required by 10 CFR 50.55a, except where 4.0.E.4 relief has been requested. It further requires that the program be based on an NRC approved edition of the Code, and that performance of IST activities is in addition to other specified SRs. These requirements are adequately addressed in 10 CFR 50.54, 10 CFR 50.55a, and the ASME Code, and need not be repeated in the ITS.

A8 The ITS includes a programmatic description of ITS Specification 5.5.7, "Inservice Testing Program."

5.5.7 N/A This program captures the existing requirements for inservice testing of certain ASME Code Class 1, 2, and 3 pumps and valves as required for plants licensed prior to January 1, 1971, which are contained throughout the CTS in various SRs. These individual Surveillances are appropriately addressed to reflect this change.

A9 The CTS requirement that specifies the inservice testing activities required by the Code and applicable 5.5.7.a 4.0.E.2, 1.0.T Addenda shall be applicable as defined in Technical Specification 1.0.T, has been deleted, since CTS 1.0.T has been deleted. The ITS maintains only those Surveillance Frequencies consistent with the terminology and Frequency used in the ASME Boiler and Pressure Vessel Code and applicable to the IST Program.

JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS

SUMMARY

ITS SECTION CTS SECTION RETS 2.5, Maximum Activity in Outside Tanks, requirement has been placed in ITS 5.5.9, Explosive Gas and Storage Tank Radioactivity Monitoring Program. As such, CTS 6.22 has been supplemented in the ITS with a general program statement that addresses storage tank radioactivity monitoring to ensure appropriate controls of these requirements are maintained. In addition, CTS RETS 2.5 contains descriptive programmatic "Objective" statements concerning the maximum quantity of radioactivity allowed in outdoor storage tanks that do not have catch basins. This objective is stated in terms of limiting the quantity of radioactivity to ensure that in the event of uncontrolled release of the contents of tanks, that certain specified limits of 10 CFR 20 would not be exceeded. CTS RETS 2.5 also contains "Specifications" which address the maximum quantity of radioactive material allowed (10 curies, excluding Tritium and dissolved or entrained noble gases) and specifies surveillance to verify that the applicable tanks' contents are within the 10 curie limit as a means of achieving the specified objective 10 CFR 20 limits. Instead of specifying the curie limit for radioactivity in CTS RETS 2.5, the proposed ITS 5.5.9.b limits the allowed quantity of radioactivity contained in outdoor liquid storage tanks by addressing the maximum effluent concentration (excluding Tritium and dissolved or entrained noble gases) at the nearest potable water and surface water supplies beyond the site boundary in the'event of uncontrolled release of the contents of the tanks. In ITS 5.5.9.b these effluent concentration limits are expressed as I tima z thp.....

ntrntinn vhIipo in AnDn,1niv R Tahbl 2.Column 2 tn 10 CFR 201001-20.2402.

5.5.9.b 6.22, RETS 2.5 iU tllull I

. oI I

e qlat, l dlu,.%l IEIULI Il, V II,,J IuIIIV

-11

-,I Vl III*,-

V*I

v.

Al1 The CTS programmatic requirements for the Configuration Risk Management Program (CRMP) have 5.5.13 6.21 been editorially changed for consistency with new ITS terminology.

A12 The CTS includes Surveillance Requirements (SRs) on the SGT and CREVAS Systems filter trains.

5.5.8 4.7.B, 4.11.A CTS 4.0.B and 4.0.C currently apply to these SRs. In the ITS, these SRs are in the Administrative Controls Chapter. Since ITS SR 3.0.2 and 3.0.3 do not apply to the Administrative Controls Chapter of the ITS unless otherwise stated, the ITS includes a statement of applicability of ITS SR 3.0.2 and SR 3.0.3 to clarify that the allowances for Surveillance Frequency extensions do apply.

A13 The ITS is clarified such that the term "following painting, fire, or chemical release that could adversely 5.5.8 4.7.B.1.c, affect the ability of the charcoal to perform its intended function," refers to the charcoal filter system.

4.11.A.2 5.6, REPORTING REQUIREMENTS Al Editorial changes, reformatting., and revised numbering.q 5.6 6.9, RETS 7.3 PAGE 6 JAFNPP AI0

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION A2 CTS 6.9.A, "Routine Reports," requires that, "The following reports shall be submitted in accordance with 5.6 6.9.A 10 CFR 50 unless otherwise noted." The ITS requires that, "The following reports shall be submitted in accordance with_10_CFR_50.4."_This change provides a more specific citation of the regulation involved.

A3 The Occupational Radiation Exposure Report is editorially modified.

5.6.1 6.9.A.2, RETS 7.3.c A4 The RETS provides a narrative description of the material required to be included in the Radioactive 5.6.2, 5.6.3 RETS 7.3.c, Effluent Release Report and the Annual Radiological Environmental Operating Report. The ITS requires RETS 7.3.d that the material provided in the reports be consistent with the objectives of the ODCM, the PCP, and with 10 CFR 50.36a and 10 CFR 50, Appendix I. In making this change, many of the details provided in the RETS are not retained in the ITS, since they are already covered within the cited programs and regulations.

A5 RETS 7.3.a and 7.3.b are not retained in the ITS since these Specifications only cross reference other N/A RETS 7.3.a, specifications.

RETS 7.3.b A6 The CTS requires that a report of the results of the first five years of performance of the non-destructive N/A 6.9.B.1 inspections listed in CTS Table 4.6-1 of CTS 4.6.F, Structural Integrity, be submitted to the NRC within three months of the completion of the fifth year of the program. This Specification is not retained in the ITS since the inspection activities have been performed with satisfactory results, and the report submitted to the NRC.

A7 The CTS reference to the MCPR low flow adjustment factor K1 has been deleted. It is not necessary to N/A 6.9.A.4.a identify this particular function since the process of determining the MCPR in the COLR includes the requirement to multiply the MCPR by the appropriate Kf.

A8 The CTS reference to flow biased APRM rod blocks has been deleted since this function is not in the N/A 6.9.A.4.a ITS.

A9 ITS 5.6.6 has been added. This new Specification requires a special report to be submitted for Post 5.6.6 N/A Accident Monitoring Instrumentation when Required Actions and associated Completion Times cannot be met or more than one channel is inoperable for specific instrumentation. Since the report is referenced in Actions B and F of ITS 3.3.3.1, Post Accident Monitoring Instrumentation, the change is considered administrative.

PAGE 7 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION A10 The CTS details concerning distribution of the COLR are being deleted since the details are a duplication N/A 6.9.A.4.d of the document distribution requirements of 10 CFR 50.4.

Al1 The CTS details regarding the revision number and date of the topical reports used to determine the core N/A 6.9.A.4.b operating limits are being deleted since the complete identification of the topical reports used to prepare the COLR are to be identified in the COLR.

5.7, HIGH RADIATION AREA Al Editorial changes, reformatting, and revised numbering.

5.7 6.11, 6.11 (A)

CTS 6.0, ADMINISTRATIVE CONTROLS Al CTS 6.6.A contains requirements regarding notification and submittal of reports to the NRC pursuant to N/A 6.6.A the requirements of 10 CFR 50.73. These reporting requirements are specified within the cited regulations and need not be repeated in the ITS.

A2 CTS 6.12 requires that an industrial security program be maintained throughout the life of the plant in N/A 6.12 accordance with the provisions of the Plant Security Plan. Security requirements are adequately addressed in 10 CFR 73.55, and need not be repeated in the ITS.

A3 CTS 6.15 requires that by June 30, 1982, all safety-related electrical equipment be environmentally N/A 6.15 qualified in accordance with the Division of Operating Reactors (DOR) Guidelines or NUREG-0588. It further requires that complete and auditable environmental qualification records be available and maintained at a central location by December 1, 1980. These requirements have been satisfactorily met.

Environmental qualification requirements are adequately addressed in 10 CFR 50.49, and need not be repeated in the ITS.

A4 The following intentionally blank CTS pages have been deleted: 254e, 254f, 257, 259, 260, and 262 N/A N/A through 284.

PAGE 8 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION RETS 2.1, LIQUID EFFLUENT MONITORS NONE NONE NONE NONE RETS 2.2, CONCENTRATION OF LIQUID EFFLUENTS NONE NONE NONE NONE RETS 2.3, DOSE FROM LIQUID EFFLUENTS NONE NONE NONE NONE RETS 2.4, LIQUID RADIOACTIVE WASTE TREATMENT SYSTEM OPERATIONS NONE NONE NONE NONE RETS 3.1, GASEOUS EFFLUENT MONITORS NONE NONE NONE NONE RETS 3.2, GASEOUS DOSE RATES NONE NONE NONE NONE RETS 3.3, AIR DOSE, NOBLE GASES NONE NONE NONE NONE PAGE 9 JAFNPP

TABLE A - ADMINISTRATIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION RETS 3.4, DOSE DUE TO IODINE-1i31, IODINE-1i33, TRITIUM, AND RADIONUCLIDES IN PARTICULATE FORM NONE NONE NONE NONE RETS 3.6, OFFGAS TREATMENT SYSTEM NONE NONE NONE NONE RETS 4.0, SOLID RADIOACTIVE WASTE - PROCESS CONTROL PROGRAM NONE NONE NONE NONE RETS 5.0, TOTAL DOSE - TOTAL DOSE FROM URANIUM FUEL CYCLE NONE NONE NONE NONE RETS 6.1, MONITORING PROGRAM NONE NONE NONE NONE RETS 6.2, LAND USE CENSUS PROGRAM NONE NONE NONE NONE RETS 6.3, INTERLABORATORY COMPARISON PROGRAM PAGE 10 JAFNPP

ATTACHMENT 3 Table M - More Restrictive Changes Matrix

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 1.0 - USE AND APPLICATION

SUMMARY

M1

ý

ý ITS SECTION CTS SECTION Table 1.1-1 Table 1.1-1 ITS SECTION CTS SECTION 1.0.C, 1.0.1.1, 1.0.1.3.a, 1.0.1.3.b 1.0.D 1.3 N/A The status of the reactor vessel head closure bolts (all fully tensioned or one or more not fully tensioned) has been added to the CTS definitions of Cold Condition, Refuel Mode, Hot Shutdown and Cold Shutdown. The added head closure status in the CTS definitions addresses plant conditions satisfying more than one MODE. The intent of this change is to provide clarity and completeness in avoiding any potential misinterpretation.

Deleted the CTS Hot Standby definition limitations on reactor coolant temperature and pressure. The ITS definition will not restrict MODE 2 to only when temperature is above 212fF or reactor pressure is less than 1040 psig1.

ITS Section 1.3 describes Completion Times in order to direct the ITS user on how to correctly apply Completion Times in the ITS. One specific requirement in Section 1.3 describes the use of Completion Times for the case in which two subsystems become inoperable concurrently without a note which allows the Conditions to be entered separately. In this case, if one subsystem were restored (within the Completion Time for two subsystems inoperable), the shorter of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or the remainder of the subsystem's completion time (for one subsystem inoperable) is allowed to restore the other subsystem to OPERABLE status. Currently, depending on the situation, JAFNPP may take the remainder of the Completion Time of the subsystem which is inoperable even if this time is greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Thus, the addition of this more restrictive requirement of Section 1.3.

CTS defines "Reactor Power Operation" to be any operation with the Reactor Mode Switch in the Startup/Hot Standby or Run position with the reactor critical and above 1% rated thermal power. In addition, CTS 1.0.1 and 1.0.1.2 define the Run Mode to be when the Reactor Mode Switch is in the Run position and reactor system pressure is at or above 850 psig. In the ITS, these explicit definitions are not retained, however; the CTS LCOs which currently reference these Modes will use the terms MODE 1 (Reactor Mode Switch in Run) and MODE 2 (Reactor Mode Switch in Startup/Hot Standby) as reflected in ITS Table 1.1-1. Since the requirement that the reactor must be critical and above 1% rated thermal power has been deleted, and since the pressure limitation has been removed for the Run Mode Applicability, this change is considered more restrictive on plant operations since the CTS LCOs which currently reference these definitions will be applicable even if the reactor is not critical, even if thermal power is at or below 1% rated thermal power, and even if reactor pressure is below 850 psig.

1.0.0, 1.0.1, 1.0.1.2 I _________________________________

PAGE 1 JAFNPP DOC #

Table 1.1-1 M2 M3 I

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 2.0 - SAFETY LIMITS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The Applicability for the Reactor Water Level Safety Limit has been changed from when the reactor is in 2.1.1.3 1.1.D the shutdown condition to all Modes.

M2 A new requirement has been added if a safety limit is not met. This new requirement will stipulate that 2.2.1, 2.2.2 6.7, 6.7.(A)

"compliance with all SLs" be restored within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. In addition, a 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> time limit is being added to "insert all insertable control rods" if a safety limit is exceeded.

PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.0 - LCO AND SR APPLICABILITY JAFNPP DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The CTS requires the unit be placed in COLD SHUTDOWN (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if the LCO or LCO 3.0.3 3.0.C action requirements cannot be satisfied because of circumstances in excess of those addressed in the Specifications. The ITS requires that the plant take action within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to initiate the shutdown, be in MODE 2 in 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />, be in MODE 3 in 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br />, and be in MODE 4 in 37 hours4.282407e-4 days <br />0.0103 hours <br />6.117725e-5 weeks <br />1.40785e-5 months <br />. Since this change requires the plant to take action within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and to be at interim conditions, MODE 2 in 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> and MODE_3_in_13_hours,_this portion of the change is more restrictive.

M2 The CTS does not address Frequencies specified as once. The ITS includes the phrase "For SR 3.0.2 4.0.B Frequencies specified as "once," the above interval extension does not apply." This is because the interval extension concept is based on scheduling flexibility for repetitive performance and these Surveillances are not repetitive in nature and essentially have no interval as measured from the previous performance. This change precludes the ability to extend these performances.

PAGE 1

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS

SUMMARY

3.1.1, SHUTDOWN MARGIN M1 The CTS requires inoperable control rods to be positioned so that CTS 3.3.A.1 (ITS LCO 3.1.1) is met.

3.1.1 ACTIONS 3.3.A.2.e No specific time limit is provided. If SDM is not met while the plant is in MODE 1 or 2, the ITS Actions A, B, C, D, and will require the SDM to be restored in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> or be in MODE 3 in the following 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. If SDM is not E

met in MODE 4 or 5, the ITS Actions require action to be initiated immediately to insert all insertable control rods (in the core cells containing fuel if in MODE 5), to immediately suspend CORE ALTERATIONS (if applicable), and to initiate actions within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to restore secondary containment, SGT System and the Secondary Containment Isolation Valves (SCIVs) to Operable status.

M2 The CTS requires that SDM be verified following a refueling outage. The ITS requires SDM to be verified SR 3.1.1.1 4.3.A.1 once within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> after criticality following fuel movement within the reactor pressure vessel or control rod replacement and prior to each in vessel fuel movement during the fuel loading sequence. Therefore, a finite time (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> after criticality) is now provided to verify SDM following a refueling outage. In addition, a new Surveillance Frequency for SDM verification has been added to clarify the requirements necessary for assuringSDM during the refueling process.

3.1.2, REACTIVITY ANOMALIES M1 The CTS Applicability has been expanded from during "power operation" to "MODES 1 and 2."

3.1.2 3.3.D M2 The CTS requirement that the plant be placed in cold shutdown within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if the Reactivity Anomaly 3.1.2 Required 3.3.E requirements are not met, is being deleted (see DOC L2). The ITS will require the plant to be in MODE 3 Action B.1 (i.e., outside the Applicability requirements) within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> if the Required Action and associated Completion Time of Condition A are not met.

M3 The CTS requires a comparison of the critical rod configurations to the expected configuration during SR 3.1.2.1 4.3.D startup following refuel outages. ITS SR 3.1.2.1 requires a verification that the core reactivity difference between the measured rod density and the predicted rod density is within + 1% Ak/k once within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after reaching equilibrium conditions following startup after fuel movement within the reactor pressure vessel or control rod replacement (1st frequency). This change is more restrictive since the proposed surveillance is explicit on the Frequency (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after reaching equilibrium conditions) and provides an additional condition for performingq the surveillance_(control rod replacement).

PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.1.3, CONTROL ROD OPERABILITY M1 The CTS requires an inoperable control rod or an uncoupled control rod to be disarmed, but does not 3.1.3 Required 3.3.A.2.b, provide a finite time to complete the action, nor does it require the control rods to be inserted prior to Actions C.1 and 3.3.A.2.c, disarming. In addition, the CTS allows a control rod inoperable due to a scram time greater than 7 C.2 3.3.B.1 seconds to not be disarmed, provided it can be inserted. The ITS requires that if a rod is considered inoperable for any reason (including excessive scram time), it must be fully inserted within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> (unless it is stuck)_and disarmed within_4_hours.

M2 The CTS allows the plant to restart and continue operation with multiple stuck control rods if: 1) collet 3.1.3 Required 3.3.A.2.a housing failure is eliminated as a potential cause; 2) sufficient control rods remain operable to make the Action B.1 core subcritical with the most reactive rod fully withdrawn (i.e., SDM is maintained); and 3) the stuck rod is disarmed. The ITS will require Hot Shutdown (MODE 3) within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> when more than one control rod is stuck but not fully inserted,_regardless of the reasons for the stuck control rods.

M3 The CTS requires that control rods be "exercised one notch," which could be met by withdrawing the SR 3.1.3.2, SR 4.3.A.2.a control rod one notch. The ITS requires control rods to be "inserted" at least one notch, in lieu of the 3.1.3.3 existing requirement for "exercising."

M4 The control rod exercise Surveillance initial condition "when operating above 30 percent power" is 3.1.3 Required 4.3.A.2.a changed to "THERMAL POWER is greater than the LPSP of the RWM." Since the LPSP is set well Action A.3 below the 30% RTP level (the RWM must be operable equal to and less than 10% RTP), this change is Completion more restrictive than present requirements but does not impose any safety concerns since at power Time, SR levels above the LPSP notch insertions will not impact the requirements of the Banked Position 3.1.3.2 and SR Withdrawal Sequence.

3.1.3.3 Notes M5 The CTS requires that inoperable (and stuck) control rods be positioned such that SDM requirements are 3.1.3 Required 3.3.A.2.e maintained. The CTS also requires the reactor to be in Cold Shutdown within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (see DOC L6)

Actions A.4, when a control rod is first found to be stuck. The ITS 3.1.3 includes additional requirements that: a) with B.1, C.1, and one stuck rod, SDM be verified within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />; b) with more than one stuck rod, the reactor be in Hot E.1 Shutdown within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />; and c) with one or more inoperable control rods, each inoperable control rod must be inserted. In addition, if the first or third requirement listed above cannot be met the reactor must be placed in MODE 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS

SUMMARY

ITS SECTION CTS SECTION The CTS specifies a maximum scram time, but does not include an explicit Surveillance with an SR 3.1.3.4 3.3.C.3 appropriate Frequency that verifies the maximum scram time. The ITS includes a Surveillance with an appropriate Frequency (in accordance with SR 3.1.4.1, SR 3.1.4.2, SR 3.1.4.3, and SR 3.1.4.4).

3.1.4, CONTROL ROD SCRAM TIMES M1 The CTS gives the Applicability of minimum scram times as "in the reactor power operation condition,"

3.1.4 3.3.C.1 which is defined as greater than 1% RTP. The ITS has minimum scram times limits applicable during Applicability MODES_1_and_2.

M2 Revises the requirements of the control rod scram time to ensure the negative scram reactivity LCO 3.1.4, 3.3.C corresponding to that used in licensing basis calculations is supported by individual control rod drive Table 3.1.4-1 scram performance distributions allowed by the Technical Specifications. Provides new individual control rod scram time limits, limits the number of slow control rods to 10, ensures no more than 2 slow rods occupy adjacent locations, and ensures that a control rod is not inadvertently considered "slow" when the scram time exceeds 7 seconds.

M3 An additional Surveillance is added to perform scram time tests on all control rods prior to exceeding SR 3.1.4.1 N/A 40% RTP after each reactor shutdown Ž 120 days.

M4 Two Surveillance Requirements are added requiring a scram time test after work on a control rod or CRD SR 3.1.4.3, SR N/A that could affect the scram time (SRs 3.1.4.3 and 3.1.4.4 2nd Frequency) and after fuel movement within 3.1.4.4, Table affected core cells (SR 3.1.4.4 1st Frequency). SR 3.1.4.3 will require a scram time test, which may be 3.1.4-1 Note (b) done at any pressure, prior to declaring a control rod Operable (and thus, enabling its withdrawal during a startup). SR 3.1.4.4 will require a scram time test after reactor pressure has reached >_ 800 psig and prior to exceeding 40% RTP. To allow testing at less than normal operating pressures, a requirement for scram time limits at < 800 psig (any reactor steam dome pressure) is included. ITS 3.1.4-1 Note (b) indicates that the scram times as a function of reactor steam dome pressure must be within established limits when reactor steam dome pressure is < 800 psig.

M5 The CTS requirement to place the plant in the cold shutdown condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if the scram time 3.1.4 Required 3.3.E limits*are.not met has been changed in theITS to require the plant to be inMODE_3_within_12_hours.

ActionA.1 PAGE 3 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS

SUMMARY

ITS SECTION CTS SECTION Changes the pressure at which the control rods must be tested from > 950 to Ž 800 psig, corresponding SR 3.1.4.2, SR 4.3.C.1, to the limiting pressure for CRD scram testing for the FitzPatrick CRD System.

3.1.4.4 4.3.C.2 3.1.5. CONTROL ROD SCRAM ACCUMULATORS M1 The CTS requires a check of the status of the pressure and level alarms for each control rod scram accumulator once per week. The ITS adds the acceptance criteria for accumulator pressure (>2 940 psig).

'I- -6.D PATTERN CONTROL M1 The CTS requires the control rod patterns to be equivalent to those prescribed by the BPWS "if the 3.1.6 3.3.B.3.f reactor is in the run or startup mode at less than 10% rated thermal power". The ITS Applicability Applicability requires that Operable control rods comply with the requirements of BPWS in "MODES 1 and 2 with THERMAL POWER : 10% RTP". Thus the new Applicability requires the control rod pattern to comply with BPWS at 10% RTP, whereas the CTS does not.

M2 The ITS adds an SR to verify all Operable control rods comply with BPWS every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

SR 3.1.6.1 N/A 3.1.7, STANDBY LIQUID CONTROL SYSTEM M1 The CTS requires the verification that all valves (manual, power operated, or automatic) in the system SR 3.1.7.4, SR 4.4.A.1 flowpath that is not locked, sealed or otherwise secured in position is in the correct position. There are 3.1.7.6 no power operated or automatic valves in the system except for the explosive valves. This Surveillance is included as ITS SR 3.1.7.6 for all manual valves, and a new requirement has been added to verify the

_ continuitvyof each explosive charge.

PAGE 4 JAFNPP I

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.1 - REACTIVITY CONTROL SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS requires verification that heat traced piping between the SLC storage tank and the pump SR 3.1.7.9 4.4.A.3 suction is unblocked (by manually initiating the system, except explosive valves, and pump boron solution from the SLC storage tank through the recirculation path) once every 24 months. The ITS requires verification that heat traced piping between the SLC storage tank and the pump suction is unblocked once per 24 months and includes an additional Frequency of "Once within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after piping temperature is restored within the limits ofFigure_3.1.7-2."

M3 The CTS has requirements for checking the concentration of sodium pentaborate in the SLC Tank after SR 3.1.7.5 4.4.C.1 certain events which could affect boron concentration occur (adding water to tank, adding boron to tank, or if temperature of solution in tank drops below the temperature limit). The CTS does not specify any time requirement for performing these checks. The ITS adds a time limit of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> into the requirement to check sodium pentaborate concentration after additions to the SLC Tank are made (water or sodium pentaborate). The ITS also adds a second time requirement to check the concentration within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after solution temperature is restored within limits.

M4 The CTS requires that the enrichment of the Boron-10 (in the SLC tank) be checked once per 24 months, SR 3.1.7.10, SR 4.4.C.4 but the CTS contains no requirement for checking the Boron-10 enrichment of sodium pentaborate being 3.1.7.11 added to the tank. In addition to the above requirement, the ITS will also require that a Boron-10 enrichment verification be done prior to adding sodium pentaborate to the tank. Since the enrichment of a batch/lot of sodium pentaborate will not change with time, a single isotopic test of any given batch/lot can suffice as the required analysis for any number of mixings and additions from that batch/lot.

M5 The CTS requires the firing of SLC primer assemblies prior to being installed into the plant, but does not SR 3.1.7.8 4.4.A.4, require firing of the primer assemblies during the flow test. The ITS will require the firing of an installed 4.4.A.5 primer assembly as part of the SLC flow test to ensure the primer assembly opens the associated SLC valve.

3.1.8, SCRAM DISCHARGE VOLUME VENT AND DRAIN VALVES NONE NONE NONE NONE JAFNPP PAGE 5

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.2 - POWER DISTRIBUTION LIMITS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.2.1, AVERAGE PLANAR LINEAR HEAT GENERATION RATE M1 The CTS requires that APLHGR be determined "daily during reactor operation at Ž 25% rated thermal SR 3.2.1.1 4.5.H power." The ITS Frequency is "within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after 2 25% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter". This change requires the first APLHGR determination within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> while the current specification requires the same determination be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after RTP Ž 25% RTP.

3.2.2, MINIMUM CRITICAL POWER RATIO M1 The CTS requires that MCPR be determined "daily during reactor operation at Ž 25% rated thermal SR 3.2.2.1 4.1.C power." The ITS Frequency is "within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after Ž 25% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter". This change requires the first MCPR determination within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> while the current specification requires the same determination be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after RTP >2 25% RTP.

M2 The CTS requires the verification of the MCPR operating limits to be performed as specified in the Core SR 3.2.2.2 4.1.D Operating Limits Report. The ITS specifies the MCPR limits must be determined within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> after each completion of ITS SR 3.1.4.1, SR 3.1.4.2 and SR 3.1.4.4 (control rod scram time testing). This new requirement is similar to current practice as specified in the COLR but imposes more specific Surveillance IFrequencies.

3.2.3, LINEAR HEAT GENERATION RATE M1 The CTS requires that LHGR be determined "daily during reactor operation at Ž 25% rated thermal SR 3.2.3.1 4.5.1 power." The ITS Frequency is "within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after Ž 25% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter". This change requires the first LHGR determination within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> while the current specification requires the same determination be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after RTP Ž 25% RTP.

3.2.4, APRM GAIN AND SETPOINT JAFNPP PAGE 1

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.2 - POWER DISTRIBUTION LIMITS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The CTS requires that MFLPD be determined "daily during reactor power operation at Ž 25% rated SR 3.2.4.1, SR 4.1.B thermal power". The ITS Frequency is "within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after_> 25% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter". In 3.2.4.2 addition, the CTS for MFLPD also has requirements to adjust APRM setpoints if necessary in accordance with the COLR with the same Frequency as the MFLPD determination. The ITS establishes a specific Frequency of every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. These changes require the first MFLPD determination within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> while the current specification requires the same determination be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after RTP >_ 25%

RTP, and the APRM setpoint adjustment is required at a 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Frequency and not the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency presently permitted.

JAFNPP PAGE 2

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

,a 4

Q O1 O I QqTDl ItAI 'MNTATION 0o0.

I. I 1,4z) 1 Mulv-..*i I M I ~l l ul l

m~

II I

M1 The CTS allows the Scram Discharge Volume High Function to be bypassed when the mode switch is in Table 3.3.1.1-1 Table 3.1-1 refuel or shutdown. The ITS requires this Function to be OPERABLE in MODE 5 whenever any control Function 7 Note 4 rod is withdrawn from a core cell containing one or more fuel assembles.

footnote (a)

M2 The CTS requires 3 channels of Scram Discharge Volume High Water Level to be OPERABLE in each Table 3.3.1.1-1 Table 3.1-1 Trip System. In the ITS, the Scram Discharge Water Level Function has been divided into two Functions 7.a Trip Function Functions, the Scram Discharge Instrument Volume Water Level - Differential Pressure Transmitter/Trip and 7.b 12 Unit and -Level Switch, each which require 2 channels to be OPERABLE in each Trip System (for a total of 4 channels per trip system for these Functions).

M3 The CTS requires 4 channels of Main Steam Line Isolation Valve Closure to be OPERABLE in each Trip Table 3.3.1.1 -1 Table 3.1-1 System. In the ITS, 8 channels are required to be OPERABLE in each Trip System.

Function 5 Trip Function 13 M4 The ITS includes a new Surveillance Requirement to perform Logic System Functional Tests every 24 SR 3.3.1.1.13 N/A months for the following Functions: a) IRM Neutron Flux -

High (MODE 2 and MODE 5(a)); b) IRM Inop (MODE 2 and MODE 5(a)): c) APRM Neutron Flux -

High (Startup) (MODE 2); d) APRM Neutron Flux -

High (Flow Biased): e) APRM Neutron Flux High (Fixed); f) APRM Inop (MODE 1 and MODE 2); g) Reactor Pressure -

High; h) Reactor Vessel Water Level -

Low (Level 3); i) Main Steam Isolation Valve -

Closure; j) Drywell Pressure -

High; k) SDV Water Level -

High (MODE 1, MODE 2, and MODE 5(a)); I) Turbine Stop Valve -

Closure; m) Turbine Control Valve Fast Closure, EHC Trip Oil Pressure-Low; n) Reactor Mode Switch -

Shutdown Position (MODE 1, MODE 2. and MODE 5(a)); and o) Manual Scram (MODE 1, MODE 2, and MODE 5(a)).

M5 The ITS includes a new Surveillance Requirement to perform Channel Checks every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> for the SR 3.3.1.1.1 N/A Functions listed below: a) IRM Neutron Flux -

High (MODE 2 and MODE 5(a)); b) APRM Neutron Flux -

High (Startup) (MODE 2); c) APRM Neutron Flux -

High (Fixed) (MODE 1); and d) APRM Neutron Flux -

High (Flow Biased) (MODE 1).

PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M6 The CTS Channel Check Frequency is increased from daily to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the ITS for the following SR 3.3.1.1.1 Table 4.1-1 Functions: a) Reactor Pressure -

High; b) Drywell Pressure -

High; c) Reactor Vessel Water Channel Level -

Low (Level 3); d) Scram Discharge Volume Water Level-High (DP transmitter/trip unit); and e)

Check J_ Turbine First Stage Pressure Permissive.

Frequency M7 A new Surveillance Requirement has been added to verify SRM and IRM channels overlap prior to fully SR 3.3.1.1.5 N/A withdrawing SRMs.

M8 The CTS specifies that the response time of the reactor protection system trip functions listed shall be SR 3.3.1.1.15 4.1.A demonstrated to be within its limit once per 24 months. Each test shall include at least one channel in each trip system. All channels in both trip systems shall be tested within two test intervals. In the ITS, the RPS RESPONSE TIME test must be performed every 24 months on a STAGGERED TEST BASIS.

In addition, a Note to this SR specifies that "n" equals 2 channels for the purpose of determining the STAGGERED TEST BASIS Frequency. Therefore, the ITS will require all channels requiring response time testing to be tested in two (2) surveillance intervals. This change is more restrictive since at least eight (8) ITS 3.3.1.1 Function 5 (Main Steam Isolation Valve -

Closure) channels and four (4) ITS 3.3.1.1 Function 8 (Turbine Stop Valve -

Closure) channels must be tested each interval instead of one channel in each trip system required by the CTS.

M9 Not used N/A N/A M10 The CTS requires a heat balance for APRM High Flux Output Signal calibration; however, no SR 3.3.1.1.2 Table 4.1-2 acceptance criteria is provided. The ITS requires that the absolute difference between the APRM Calibration channels and the calculated power be

  • 2% RTP plus any gain adjustment required by LCO 3.2.4, Frequency for "Average Power Range Monitor (APRM) Gain and Setpoint" while operating at >_ 25% RTP.

Instrument Channel 2 M11 Not used N/A N/A M12 The CTS requires actuation of the MSIV Closure limit switches and Turbine Stop Valve Closure SR 3.3.1.1.12 Table 4.1-2 pressure switches by normal means every 24 months. The ITS requires an actual Channel Calibration Note 4 of these instruments everV_24_months to ensure channelOPERABILITY.

JAFNPP PAGE 2

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M13 A new Surveillance Requirement has been added to verify, every 24 months, the Turbine Stop SR 3.3.1.1.14 N/A Valve -

Closure and Turbine Control Valve Fast Closure, EHC Oil Pressure -

Low Functions are not bypassed when THERMAL POWER is Ž 29 % RTP.

M14 The CTS requires a comparison of the IRM channels with the APRM channels on a controlled shutdown.

SR 3.3.1.1.6 Table 4.1-2 However, the requirement is only associated with the IRM High Flux Function. In the ITS, this Calibration Surveillance is associated with not only the IRM Neutron Flux-High, but also the APRM Neutron Flux-Frequency for High (Startup). In addition, a Note is included in the ITS that states the SR is only required to be met Instrument during entry into MODE 2 from MODE 1 since this is when the IRM and APRM channels are designed to Channel 1 overlap with one another. Currently, the Surveillance implies that the calibration is to be performed on controlled shutdowns only.

M15 The CTS actions for the APRM Inoperative Function provides an option of either inserting all Operable 3.3.1.1 Table 3.1-1 rods within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> (being in MODE 3), or reducing power to the IRM range and placing the reactor ACTION G Notes 3.A and mode selector switch in startup (being in MODE 2) within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> if the APRM Inoperative Function has 3.B less than the minimum number of Operable channels per trip system. The ITS requires entry into MODE 3 since theAPRMInoperativeFunction is required inMODES_1_and_2.

M16 Not used.

N/A N/A M17 The CTS requires the plant to be in Startup within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> when CTS Table 3.3-1 Notes 1 and 2 (as 3.3.1.1 Action F Table 3.3-1 applicable) are not met for inoperable APRM Flow Referenced Neutron Flux or APRM Fixed High Note 3.B Neutron Flux High channels. The ITS will require the plant to be in MODE 2 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, a decrease of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

3.3.1.2, SRM INSTRUMENTATION M1 The CTS require two Source Range Monitors (SRMs) to be Operable whenever control rods are Table 3.3.1.2-1 3.3.B4 withdrawn for startup. The ITS will require three SRMs to be Operable at all times in MODE 2 until the Function 1, 4.3.B.4 flux level is sufficient to maintain the Intermediate Range Monitor on Range 3 or above, including footnote (a)

JAFNPP PAGE 3

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M2 A new requirement is being added to require 2 SRM channels to be Operable at all times in MODE 3 Table 3.3.1.2-1, N/A and MODE 4 because the SRMs are the primary indication of neutron flux levels in these MODES. In 3.3.1.2 addition, an appropriate ACTION and Surveillance Requirements have also been added.

ACTION D, SR 3.3.1.2.3, SR 3.3.1.2.4, SR 3.3.1.3.6, SR 3.3.1.2.7 M3 The CTS requires a count rate verification "prior to control rod withdrawal for startup or during refueling."

SR 3.3.1.2.4 4.3.B.4, The CTS also requires a count rate verification "prior to making alterations to the core" and daily 4.10.B thereafter. The ITS will requires periodic verification of the SRM count rate at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> while in MODE 2 when IRMs are on Range 2 or below and every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during CORE ALTERATIONS.

M4 Two new MODE 2 (when IRMs are on Range 2 or below) Surveillance Requirements are being added.

SR 3.3.1.2.1, N/A The new Surveillances will require a) performance of an SRM Channel Check every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />; and b)

SR 3.3.1.2.6 performance of an SRM Channel Functional Test and determination of signal to noise ratios every 31 days. In addition, the Channel Functional Test Surveillance is modified by a Note that will allow deferral of this Surveillance until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the IRMs are on Range 2 or below when the reactor is being shutdown.

M5 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if a required 3.3.1.2 N/A SRM is inoperable. In the ITS, an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Required Action C.1 M6 A new Surveillance Requirement is being added to verify every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during CORE ALTERATIONS SR 3.3.1.2.2 N/A that the SRMs are properly located.

M7 A new Surveillance Requirement is being added to state that the 3 cps count rate requirement is based SR 3.3.1.2.4 N/A on a signal to noise ratio of > 2:1. Currently, the CTS just list the count rate requirement but does not specify what signal to noise ratio it is based upon._II JAFNPP PAGE 4

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M8 The CTS does not specify any Required Actions if SRM Operability requirements in MODE 5 are not 3.3.1.2 N/A satisfied. The ITS includes Required Actions if less than the required number of SRMs are Operable in ACTION E MODE 5. If one or more required SRMs are inoperable when in MODE 5, the ITS will require that CORE ALTERATIONS be terminated and action be taken immediately to fully insert all control rods in core cells containing one or more fuel assemblies.

M9 A new MODE 5 Surveillance Requirement has been added to perform a Channel Calibration every 92 SR 3.3.1.2.7 4.10..B days. In addition, the Surveillance has been modified by a Note that excludes the neutron detectors from calibration requirements.

M10 The CTS requires the SRMs to be functionally tested prior to making Core Alterations. The ITS requires SR 3.3.1.2.5 4.10.B a CHANNEL FUNCTIONAL TEST be performed every 7 days when in MODE 5, which includes Core Alterations. In addition, the ITS also requires the determination of the signal to noise ratio (as modified by the SR Note).

M11 The CTS requires the SRMs to be checked for neutron response prior to Core Alterations and checked SR 3.3.1.2.1 4.10.B daily thereafter. The ITS requires the performance of a CHANNEL CHECK every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> during MODE_5_(which includesCoreAlterations).

3.3.2.1, CONTROL ROD BLOCK INSTRUMENTATION M1 A new Function has been included in the ITS. 2 channels of the Rod Block Monitor-Inop Function are Table 3.3.2.1-1 N/A now required to be Operable consistent with the Applicability with the other Rod Block Monitor Function 1.b, Functions. In addition, appropriate ACTIONS and Surveillance Requirement have also been added.

3.3.2.1 ACTIONS A and B, SR 3.3.2.1.1, SR 3.3.2.1.4 PAGE 5 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M2 A new Function has been included in the ITS. 2 channels of the Rod Block function of Reactor Mode Table 3.3.2.1-1 N/A Switch -

Shutdown Position must be Operable whenever the Mode Switch is in the Shutdown position.

Function 3, In addition, an appropriate ACTION and a Surveillance Requirement have also been added.

3.3.2.1 ACTION E, SR 3.3.2.1.7 M3 The CTS provides a restoration time of 7 days when one RBM channel is inoperable. The ITS will only 3.3.2.1 Table 3.2-3 allow 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for the same condition.

Required Note 2 Action Action A.1 B.a)

M4 A new Surveillance has been added to verify, every 92 days, that the RBM-Upscale and -Downscale SR 3.3.1.2.4 N/A Functions are not bypassed at Thermal Power Ž 30% RTP and when a peripheral control rod is not selected.

M5 A new Surveillance Requirement is being added to perform, every 92 days, a CHANNEL FUNCTIONAL SR 3.3.2.1.3 N/A TEST in MODE 1 when Thermal Power is

  • 10% to ensure the RWM is Operable with the reactor mode switch inRUN.

M6 A new Surveillance Requirement is being added to verify every 24 months that the Rod Worth Minimizer SR 3.3.2.1.6 N/A is not bypassed when Thermal Power is _< 10%.

3.3.2.2, FEEDWATER AND MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION None None None None 3.3.3.1, PAM INSTRUMENTATION PAGE 6 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

ITS SECTION CTS SECTION The required number of channels for all CTS PAM instrumentation Functions maintained in the ITS is being increased from 1 channel to 2 channels in the ITS. In addition, the CTS allows 30 days to restore the one required channel (i.e., both channels are inoperable, since only one of the two is required to be Operable). Under the same conditions (both required channels inoperable), the ITS will only allow 7 days to restore one of the channels. Also, the ITS limits the time one of the two required channels can be inoperable to 30 days, and if not restored, requires a special report to be submitted to the NRC.

Table 3.3.3.1-1 Functions 1 through 6 and 8 through 10 Required

Channels, 3.3.3.1 ACTIONS A, B, and C Table 3.2-8 Instruments 4 through 14 Minimum no.

of Operable Channels

Required, Table 3.2-8 Notes A and F

M2 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if a required PAM 3.3.3.1 Table 3.2-8 channel is not restored to Operable status with the allowed time. In the ITS, MODE 3 must be met Required Note A within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Action E.1 M3 A new PAM Function has been included in the ITS. 2 channels per penetration flow path of the 3.3.3.1 N/A Penetration Flow Path PCIV position Function are required to be Operable in MODES 1 and 2, except Applicability, only one is required for those penetrations with only one installed control room indicator and none are Table 3.3.3.1-1 required if the penetration flow path is properly isolated. Appropriate ACTIONS and Surveillance Function 7, Requirements have also been added.

3.3.3.1 ACTIONS A, B, C, D, and E, SR 3.3.3.1.1, SR 3.3.3.1.3 M4 A new PAM Function has been included in the ITS. 2 channels of the Drywell Water Level Function are 3.3.3.1 N/A required to be Operable in MODES 1 and 2. Appropriate ACTIONS and Surveillance Requirements Applicability, have also been added.

Table 3.3.3.1-1 Function 11, 3.3.3.1 ACTIONS A, B, C, D, and E, SR 3.3.3.1.1, SR 3.3.3.1.3 PAGE 7 liI JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

ITS SECTION CTS SECTION

.1 ________________

3.3.32 9 REMOTF SHUTDOWN SYSTEM M1 The CTS Applicability is "Run and Startup/Hot Standby" modes. The CTS definition of Hot Standby 3.3.3.2 3.2.J includes operation with coolant temperature > 212 OF. In the ITS, the Applicability is MODES 1 and 2, Applicability which includes a control rod withdrawn (for the purposes of starting up) when < 212 OF.

M2 The CTS provides an allowance that the requirements of CTS 3.2.J (the Remote Shutdown instrument N/A 3.2.J.5 and control circuit LCO) do not apply if the component actuated by a required control circuit is inoperable. This explicit allowance is not included in the ITS and is being deleted. If operating in MODES 1 and 2, all of the controls appearing in the ITS must be Operable to support equipment that has been tested in accordance with its associated Surveillance Requirements and is also considered Operable. If this is not the case, then the specified control will not be able to support the required safe shutdown safety functions defined in the Bases of ITS 3.3.3.2. If a component actuated by a required Remote Shutdown Circuit is inoperable and the other Technical Specifications allow continuous operation without this component (e.g., Safety/Relief Valves), then this component should be restored to Operable status within 30 days since the Remote Shutdown safe shutdown requirements may not be met. In most cases, the Completion Times of other Specifications (e.g., ITS 3.5.1, ECCS) will govern the allowed out of service time when required mechanical or electrical equipment are inoperable, since the times provided in the other Specifications are normally less than Remote Shutdown LCO Completion Times.

M3 With one or more required remote shutdown instrumentation circuits inoperable, the CTS provides an N/A 3.2.J.2.b, option to establish an alternate method of monitoring the parameter within 30 days and to restore the 3.2.J.3.b required instrument circuit to operable status within 90 days. With one or more required control circuits inoperable, the CTS provides an option to place the component actuated by that control circuit in the safe shutdown configuration. These options have not been included in the ITS; the restoration of the inoperable components is required.

3.3.4.1, ATWS-RPT INSTRUMENTATION PAGE 8 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION,

DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The CHANNEL CHECK Frequency is being increased from daily in the CTS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the SR 3.3.4.1.1 Table 4.2-7 ITS.

Channel Check Frequency M2 The CTS Trip Level Setting (changed to Allowable Value as discussed in DOC A7) for the Reactor SR 3.3.4.1.4 Table 3.2-7 Pressure High Trip Function from *51155 psig to < 1153 psig.

Trip Level Setting for the Reactor Pressure High Trip Function M3 The ITS includes a Note that precludes placing a channel in trip to meet the required actions if the 3.3.4.1 N/A inoperable channel is the result of an inoperable breaker, since this would not adequately compensate Required for the inoperability.

Action A.2 Note 3.3.5.1, ECCSINSTRUMENTATION M1 The CTS minimum number of Operable Channels for the Condensate Storage Tank Level - Low Trip Table 3.3.5.1-1 Table 3.2-2 Function has been increased from 2 channels to 4 channels in the ITS, since there are two condensate Function 3.d Item No. 17 storage tanks, and each have 2 channels.

M2 Five new Functions have been included in the ITS: a) Core Spray Pump Discharge Flow -

Low Table 3.3.5.1-1 N/A (Bypass); b) Core Spray Pump Discharge Pressure -

High (Bypass); c) Low Pressure Coolant Injection Functions 1.e, Pump Discharge Flow -

Low (Bypass); d) High Pressure Coolant Injection Pump Discharge 1.f, 2.g, 3.f, and Flow -

Low (Bypass); and e) High Pressure Coolant Injection Pump Discharge Pressure -

High 3.g, 3.3.5.1 (Bypass). In addition, and appropriate ACTION and Surveillance Requirements have also been added.

ACTION E, SR 3.3.5.1.3, SR 3.3.5.1.5, SR 3.3.5.1.6 JAFNPP PAGE 9

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M3 The CHANNEL CHECK Frequency is being increased from daily in the CTS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the ITS SR 3.3.5.1.1 for Table 4.2-2 for the reactor water level high and low, drywell pressure high, and reactor pressure low Instrument Functions 1.a, Instrument Channels.

1.b, 1.c, 2.a, Check 2.b, 2.c, 2.d, Frequency for 2.e, 3.a, 3.b, Instrument 3.c, 4.a, 4.c, 5.a, and 5.c M4 Not used.

N/A N/A M5 Not used.

N/A N/A M6 The CTS Trip Level Setting (changed to Allowable Value as discussed in DOC Al12) for the Reactor Low Table 3.3.5.1-1 Table 3.2-2 Level (inside shroud) Trip Function from > 0.0 inches to > 1.0 inches.

Function 2.e Item No. 5 Allowable Trip Level Value Setting 3.3.5.2, RCIC SYSTEM INSTRUMENTATION M1 The CHANNEL CHECK Frequency is being increased from daily in the CTS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the ITS SR 3.3.5.2.1 for Table 4.2-2 for the reactor water level high and low Instrument Channels.

Functions 1 Instrument and 2 Check Frequency for Instrument Channel_1 JAFNPP PAGE 10

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M2 A new Function has been added. The ITS requires 1 channel of the RCIC Manual initiation Function to 3.3.5.2 N/A be Operable in MODE 1 and MODES 2 and 3 with reactor steam dome pressure > 150 psig. In addition, Applicability, appropriate ACTIONS and a Surveillance Requirement have also been added.

Table 3.3.5.2-1 Function 4, 3.3.5.2 ACTIONS C and E, SR 3.3.5.2.6 M3 The CTS minimum number of Operable Channels for the Condensate Storage Tank Level - Low Trip Table 3.3.5.2-1 Table 3.2-2 Function has been increased from 2 channels to 4 channels in the ITS, since there are two condensate Function 3 Item No. 16 storage tanks,_and each have_2_channels.

3.3.6.1, PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION M1 The CHANNEL FUNCTIONAL TEST Frequency is being increased from every 24 months (R) in the CTS SR 3.3.6.1.2 Table 4.2-8 to every 92 days in the ITS for the containment high range radiation monitor. In addition, a LOGIC and SR Instrument SYSTEM FUNCTIONAL TEST 24 month Surveillance is also being added for this Function.

3.3.6.1.7 for Functional Table 3.3.6.1-1 Test Function 2.c Frequency for Instrument 4 M2 The ITS includes a new Applicability of MODES 4 and 5 for the RHR SDC Reactor Vessel Water Level -

Table 3.3.6.1-1 Table 3.2-1 Low Function. Also, the ITS includes a Note that only one trip system is required in MODES 4 and 5, Function 6.b Trip Function provided the RHR SDC System integrity is maintained. In addition, an appropriate ACTION has also (including Note 1

been added.

e), 3.3.6.1 ACTION J M3 Not used.

N/A N/A PAGE 11 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M4 The CTS specifies that the main steam isolation valve actuation instrumentation response time for the SR 3.3.6.1.8 4.2.A specified trip functions must be demonstrated to be within its limit once per 24 months. Each test shall include at least one channel in each trip system. All channels in both trip systems shall be tested within two test intervals. In the ITS, the ISOLATION INSTRUMENTATION RESPONSE TIME test must be performed every 24 months on a STAGGERED TEST BASIS. In addition, a Note to this SR specifies that "n" equals 2 channels for the purpose of determining the STAGGERED TEST BASIS Frequency.

Therefore, the ITS will require all channels requiring response time testing to be tested in 2 surveillance intervals. This change is more restrictive since 2 channels must be tested each interval for Functions l.a and 1.b while 8 channels must be tested each interval for Function 1.c instead of one channel in each trip system required by the CTS.

M5 Not used.

N/A N/A M6 The required number of OPERABLE channels in each trip system for HPCI and RCIC Steam Line Low Table 3.3.6.1-1 Table 3.2-1 Pressure and HPCI and RCIC Turbine High Exhaust Diaphragm Pressure Functions are increased from Functions 3.b, Trip Functions 1 in the CTS to 2 in the ITS.

4.b, 3.c, and 14,15, 18, 4.c and 19 M7 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if a required 3.3.6.1 Table 3.2-1 instrumentation channel is not restored/tripped within the allowed times. In the ITS, an intermediate Required Note 3.A condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Actions D.2.1 and H.1 M8 The Completion Time provided to close the affected isolation valves is decreased from 4 or 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> in 3.3.6.1 Table 3.2-1 the CTS to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> in the ITS.

Required Notes 3.C, Action F.1 3.D, and 3.E M9 The CHANNEL CHECK Frequency is being increased from daily in the CTS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the ITS SR 3.3.6.1.1 Tables 4.1-1, for various primary containment isolation instrument channels.

4.2-1, and

_ _ _ 4.2-8 PAGE 12 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M10 The required number of OPERABLE channels in each trip system for the containment high range Table 3.3.6.1-1 Table 3.2-8 radiation monitor Function are increased from 1 in the CTS to 2 in the ITS. In addition, the CTS allowed Function 2.c, Instrument 4, restoration time from the one channel has been changed from 30 days to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in the ITS. Also, 3.3.6.1 including since both channels are currently required to be Operable, an allowance is necessary to perform the ACTION A, Note A associated Surveillances while in the applicable modes consistent with other Primary Containment Note 2 to Isolation Functions. Therefore, an ITS Note will delay entry into the associated Conditions and Required Surveillance I_ Action for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> as long as isolation capability is maintained.

Requirements M1 A new Function has been added. The ITS requires 2 channels of the SLC System Initiation Function to Table 3.3.6.1-1 N/A be Operable in MODES 1 and 2. In addition, appropriate ACTIONS and a Surveillance Requirement Function 5.d, have also been added.

including footnote d, 3.3.6.1 ACTIONS A, B, and I M12 The CTS allowance to delay entry into the associated Limiting Conditions for Operation and required N/A Table 3.2-1 action for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> during the performance of instrumentation surveillances when primary containment Note 2 isolation valves are placed in an inoperable status has not been included in the ITS.

M13 The CTS Applicability of the primary containment isolation instrumentation is whenever the reactor is Table 3.3.6.1-1 3.2.A, Table critical or when the reactor water temperature is above 212 OF and fuel is in the reactor vessel.

The 3.2-1 Note 1 Applicability in the ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the primary containment isolation instrumentation must be Operable at all times in MODE 2 even prior to I_ any plant startupnwhen reactor coolant temperature may be below 212_OF.

PAGE 13 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION

SUMMARY

ITS SECTION CTS SECTION The CTS Trip Level Setting (changed to Allowable Value as discussed in DOC Al16) for the following Functions have been changed: HPCI Steam Line Low Pressure, Main Steam Line Leak Detection High Temperature, HPCI and RCIC Steam Line/Area Temperature, RWCU System Equipment Area Temperature, Reactor High Pressure (SDC), RCIC Turbine High Exhaust Diaphragm Pressure, RCIC Turbine Steam Line High Flow, HPCI Turbine High Exhaust Diaphragm Pressure, and RCIC Steam Line Low Pressure.

Table 3.3.6.1-1 Allowable Values for Functions 1.e, 3.b, 3.c, 3.d, 3.e, 3.f, 3.g, 3.h, 3.i, 3.j, 4.a, 4.b, 4.c, 4.d, 4.e, 4.f, 5.a, 5.b, 5.c, 5.d, and 6.a

.1 1 Table 3.2-1 CTS Table 3.2-1 Note 3.B requires the main steam lines to be isolated within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> when CTS Table 3.2-1 Notes 1 and 2 (as applicable) are not met for inoperable Main Steam Line Low Pressure channels.

However, the Main Steam Line Low Pressure channels are only required to be Operable in the Run Mode (MODE 1), as stated in CTS Table 3.2-1 Note 5. As stated in CTS 3.0.A, once the plant is placed in the Startup/Hot Standby Mode (MODE 2), the Main Steam Line Low Pressure channels are no longer required to be Operable; thus the requirement in CTS Table 3.2-1 Note 3.B to isolate the main steam lines is no longer required. Effectively, the CTS requires the plant to be placed in MODE 2 within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. The ITS provides an Action consistent with the Applicability of the Main Steam Low Pressure channels; it requires the plant to be placed in MODE 2. However, in lieu of the CTS time of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to complete this action, the ITS requires MODE 2 to be reached in 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, a decrease of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

3.3.6.1 Action E Table 3.2-1 Trip Level Setting for Trip Functions 3, 10, 11, 14, 15,16,17, 18, 19, and 20 Table 3.2-1 Note 3.13 3.3.6.2, SECONDARY CONTAINMENT ISOLATION INSTRUMENTATIONI PAGE 14 JAFNPP lVI M -t M15 4

I I

3...,SCNDRIOTIMNTIOAININTUETTO 11 I

I I

I I

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M1 A new Applicability for the Reactor Vessel Water Level - Low, refuel area Exhaust Monitor, and Reactor Table 3.3.6.2-1 Table 3.2-1 Building Area Exhaust Monitor Functions is being added. These Functions are now required to be Functions 1, 3, Trip Function Operable during operations with a potential for draining the reactor vessel.

and 4 1, RETS Table 3.10-1 Trip Functions 1 and 2 M2 The CTS requires the Trip Level Setting of the Refuel Area Exhaust Monitor and Reactor Building Area Table 3.3.6.2-1 RETS Table Exhaust Monitor Functions to be in accordance with the methods and procedures of the ODCM. In the Allowable 3.10-1 Trip ITS, the actual Allowable Values are provided, not a cross reference to the ODCM.

Values for Level Setting Functions 3 for Trip and 4 Functions 1 and 2 M3 The RETS requires the isolation of the secondary containment and to start the SGT System when the 3.3.6.2 RETS Table associated instrumentation is found to be inoperable; however, no finite completion time is provided. In Required 3.10-1 Note the ITS a 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> completion time is provided to complete the actions.

Actions C.2.1 (d) and C.2.2 M4 The CHANNEL CHECK Frequency is being increased from daily in the CTS/RETS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in SR 3.3.6.2.1 Table 4.1-1, the ITS for the secondary containment isolation instrument channels.

RETS Table 3.10-2 M5 A new Surveillance Requirement is added for the Refuel Area Exhaust Monitor. The ITS requires SR 3.3.6.2.6 for N/A performance of a Logic System Functional Test every 24 months.

Table 3.3.6.2-1 Function 4 M6 The CTS allowance to delay entry into the associated Limiting Conditions for Operation and required N/A Table 3.2-1 action for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> during the performance of instrumentation surveillances when primary containment Note 2 isolation valves are placed in an inoperable status has not been included in theITS.

PAGE 15 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M7 The CTS Applicability of the primary containment isolation instrumentation is whenever the reactor is Table 3.3.6.2-1 3.2.A, Table critical or when the reactor water temperature is above 212 OF and fuel is in the reactor vessel. The 3.2-1 Note 1 Applicability in the ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the secondary containment isolation instrumentation must be Operable at all times in MODE 2 even prior to I_ any plant startup when reactor coolant temperature may be below_212_OF.

3.3.7.1, CREVAS SYSTEM INSTRUMENTATION M1 The CTS Applicability of the CREVAS System instrumentation is whenever the reactor water 3.3.7.1 3.11.A.1, temperature is above 212 OF and fuel is being handled. The Applicability in the ITS is MODES 1, 2 and Applicability 3.11.A.2.

3, during Core Alterations, during movement of irradiated fuel in the secondary containment, and during RETS 3.10 operations with a potential for draining the reactor vessel. The ITS adds new Applicability requirements that the CREVAS System instrumentation must be Operable at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below 212 OF, during control rod movement in MODE 5, and during operations with a potential for draining the reactor vessel.

M2 The CHANNEL CHECK Frequency for the CREVAS air intake radiation - high Function is being SR 3.3.7.1.1 RETS Table increased from daily in the RETS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the ITS.

3.10-2 M3 The CTS requires the initiation of the Control Room Emergency Ventilation Air Supply (CREVAS) 3.3.7.1 3.11.A.2, System in the isolate mode of operation when the Control Room Air Intake Radiation channel is ACTION A RETS Table inoperable; however, no finite completion time is provided. In the ITS, a completion time of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is 3.10-1 Note provided for this action, and an optional action is also provided. This action is to declare both CREVAS (g) subsystems inoperable within_1_hour in lieu of placing the system in the isolate mode.

3.3.7.2, CONDENSER AIR REMOVAL PUMP ISOLATION INSTRUMENTATION PAGE 16 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The CHANNEL CHECK Frequency for the Main Steam Line High Radiation Function is being increased SR 3.3.7.2.1 Table 4.2-1 from daily in the CTS to every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> in the ITS.

Instrument Check Frequency for Instrument Channel 8 3.3.7.3, ESW SYSTEM INSTRUMENTATION M1 An Allowable Value has been added for the ESW pressure instrumentation channels.

SR 3.3.7.3.1 N/A 3.3.8.1, LOP INSTRUMENTATION M1 A new Surveillance Requirement has been added to require a Logic System Functional Test of the LOP SR 3.3.8.1.2 N/A Instrumentation every 24 months.

M2 The CTS does not provide an Applicability for the LOP Instrumentation. The ITS adds the Applicability 3.3.8.1 N/A requirements of MODES 1, 2, and 3, and when the associated emergency diesel generator is required Applicability to be Operable by LCO 3.8.2.

3.3.8.2, RPS ELECTRIC POWER MONITORING M1 The CTS does not provide any actions if the RPS monitoring assemblies are inoperable in MODE 5 with 3.3.8.2 N/A a control rod withdrawn for a core cell containing one or more fuel assemblies. The ITS adds an ACTION D appropriate ACTION that requires action to be initiated immediately to insert any withdrawn control rod in cells containing fuel.

M2 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if a required RPS 3.3.8.2 3.0.C electric power monitoring assembly is not restored or taken out of service with the allowed time. In the ACTION C ITS, MODE 3 must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

JAFNPP PAGE 17

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.3 - INSTRUMENTATION PAGE 18 JAFNPP

SUMMARY

ITS SECTION CTS SECTION The CTS setpoint (changed to Allowable Value as discussed in DOC A3) for the alternate power supply SR 3.3.8.2.3 4.9.G.2 undervoltage Function has been changed from > 108 V in the CTS to > 109.9 V in the ITS.___II

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM

SUMMARY

R. RC~IRlCULATIOlN LOOPS OPERATING M1 CTS 3.5.J is applicable when the reactor is in the run mode. ITS 3.4.1 is applicable in MODES 1 and 2.

3.4.1 3.5.J This change is necessary since there is significant energy in the core in MODE 2 and postulated design basis accidents may occur in this condition.

M2 A new requirement has been added, which requires that the recirculation loop jet pump flow mismatch LCO 3.4.1, 3.4.1 N/A with both recirculation loops in operation be within the specified limits. Appropriate ACTIONS and an SR ACTIONS B and has also been added.

C, SR 3.4.1.2 M3 An SR has been added to verify operation is outside the "Exclusion Region" of the power-to-flow map SR 3.4.1.1 N/A specified in the COLR every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The SR ensures the reactor THERMAL POWER and core flows are within appropriate parameter limits to prevent uncontrolled power oscillations. At low recirculation flows and high reactor power, the reactor exhibits increased susceptibility to thermal hydraulic instability.

In addition, a Note is included which states that this SR is only required to be performed in MODE 1 because during plant operation in MODE 2 the APRM Neutron Flux-High (Startup) Function of ITS 3.3.1.1_will prevent entry into the_"ExclusionRegion."

3.4.2, JET PUMPS M1 The CTS requires that, if a jet pump is determined to be inoperable, that the reactor be placed in Cold 3.4.2 ACTION A 3.6.G Shutdown within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. CTS 3.0.A states that "Limiting Conditions for Operation and Action requirements shall be applicable during the Operational Conditions (modes) specified for each specification." CTS 3.6.G is applicable in the Startup/Hot Standby and Run MODES; therefore, the requirement to place the plant in Cold Shutdown is not applicable after reaching the Hot Shutdown mode, and the CTS essentially allows 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to reach Hot Shutdown. The ITS requires that, if one or more jet pumps are inoperable, the plant be placed in MODE 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The ITS effectively reduces the time*to reachMode_3 from_24_hours to_12_hours.

PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS requires that certain conditions do not occur simultaneously. Two of these conditions are, (1)

SR 3.4.2.1 4.6.G the two recirculation loops have a flow imbalance of Ž 10% when the pumps are operated at the same speed, and (2) the indicated value of core flow rate varies from the value derived from loop flow measurements by > 10%. The ITS specifies one condition that may be used to verify operability of the jet pumps to be, "recirculation pump flow to speed ratio and recirculation loop jet pump flow to recirculation pump speed ratio both differ by _< 5% from established patterns." This change imposes new requirements on recirculation pump flow to speed ratio and recirculation loop jet pump flow to recirculation pump speed ratio.

3.4.3, SAFETY/RELIEF VALVES M1 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if the minimum 3.4.3 Required 3.6.E.2 number of Operable safety/relief valves is not met. In the ITS, an intermediate condition, MODE 3, must Action A.1 be met within_12_hours.

M2 The CTS requires the safety/relief valves to be manual opened every 24 months. The ITS requires this SR 3.4.3.2 4.6.E.4 same manual opening, but also requires the actuation to be initiated on a Staggered Test Basis for each valve solenoid._This will ensure that both solenoids will be tested every_48_months.

3.4.4, RCS OPERATIONAL LEAKAGE M1 The CTS is revised to adopt the requirement that no Reactor Coolant System (RCS) pressure boundary LCO 3.4.4.a, 3.6.D1 LEAKAGE exist, and should it occur, to be in MODE 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in MODE 4 in 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

3.4.4 ACTION C M2 The CTS requires that the source of an increase in leakage be identified within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The ITS 3.4.4 Required 3.6.D.3 requires that the source of an increase in LEAKAGE be verified not to be service sensitive type 304 or Action B.2 type 316 austenitic stainless steel within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. This change seeks to ensure that new or additional RCS LEAKAGE is not the result of intergranular stress corrosion cracking (IGSCC) in the reactor coolant npressure boundarv_(RCPB).

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M3 The CTS requires the reactor coolant leakage into the primary containment to be within limits anytime 3.4.4 3.6.D irradiated fuel is in the reactor vessel and the reactor coolant temperature is above 212 0F. The ITS Applicability Applicability is during MODES 1, 2 and 3. The CTS requirement to be Operable when the reactor coolant temperature is greater than 212°F only covers ITS MODES 1 and 3. Therefore, the addition of MODE_2_is an additional requirement not explicitly established in theCTS.

3.4.5, RCSLEAKAGEDETECTIONINSTRUMENTATION M1 CTS Table 4.6-2 does not require performance of an Instrument Functional Test, and requires that a SR 3.4.5.1, SR Table 4.6-2 Sensor Check be performed once per day for the Containment Atmosphere Monitoring System channels.

3.4.5.2 The ITS requires that a CHANNEL CHECK be performed at a Frequency of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and a CHANNEL FUNCTIONAL TEST be performed at a Frequency of 31 days. This change imposes more frequent performance of the CHANNEL CHECK and adds the new requirement to perform a CHANNEL FUNCTIONAL TEST.

M2 CTS 3.6.D.4 requires the operability of the Primary Containment Sump Monitoring System and the 3.4.5 ACTION E N/A Continuous Atmosphere Monitoring System. CTS 3.6.D.5 provides the appropriate actions if the Primary Containment Sump Monitoring System is inoperable and CTS 3.6.D.6 provides the appropriate actions if the Continuous Atmosphere Monitoring System (particulate and gaseous) is inoperable. The CTS does not provide any restrictions if both the Primary Containment Sump Monitoring System and the Continuous Atmosphere Monitoring System (particulate and gaseous) are inoperable at the same time.

The ITS includes an ACTION that requires ITS LCO 3.0.3 be entered immediately if all leakage detection systems are inoperable.

3-46 R*P*P..PCIFIC ACTIVITY A new action has been added that will require the determination of DOSE EQUIVALENT 1-131 every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> whenever the DOSE EQUIVALENT 1-131 specific activity limit is exceeded. Currently, the CTS does not require this action.

3.4.6 Required Actions A.1 and B.1 PAGE 3 JAFNPP N/A O.L+.Dl M-40 OF 1%ý rký I IV I I I I

I

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS requires the reactor to be placed in the cold shutdown condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if 3.4.6 Required N/A the iodine concentration exceeds the equilibrium limit by more than a factor of 10. In the ITS, an Action B.2.2.1 intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M3 The Frequency to perform an isotopic analysis of a sample of reactor coolant every 31 days has been SR 3.4.6.1 4.6.C.1.b changed to at least once per 7 days.

3.4.7, RHRSHUTDOWNCOOLINGSYSTEM_-_HOT SHUTDOWN M1 A new Specification is being added requiring two RHR shutdown cooling subsystems to be Operable in 3.4.7 N/A MODE 3 with reactor steam dome pressure less than the shutdown cooling permissive pressure.

Appropriate Actions and a Surveillance Requirement are also being added. Currently, no Specification exists.

3.4.8, RHR SHUTDOWN COOLING SYSTEM - COLD SHUTDOWN M1 A new Specification is being added requiring two RHR shutdown cooling subsystems to be Operable in 3.4.8 N/A MODE 4. Appropriate Actions and a Surveillance Requirement are also being added. Currently, no Specification exists.

3.4.9, RCS P/T LIMITS M1 The CTS requires that RCS pressure and temperature be recorded within 30 minutes prior to withdrawal SR 3.4.9.2 4.6.A.4 of control rods to bring the reactor critical. The ITS requires this verification to be performed within 15 minutes prior to control rod withdrawal for the purpose of achieving criticality.

M2 The CTS requires that, in the event the RCS pressure and temperature limits are exceeded, it be 3.4.9 Required 3.6.A.5 determined that the RCS remains acceptable for continued operation. There is no Completion Time Action A.2

_.nassociatedwith this requirement._TheITS requires that this determination be made in_72_hours.

PAGE 4 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.4 - REACTOR COOLANT SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M3 The CTS requires that certain RCS differential temperature measurements be recorded within 30 SR 3.4.9.3, SR 4.6.A.6 minutes prior to startup of an idle recirculation loop. The ITS require that these differential temperature 3.4.9.5 measurements be verified within 15 minutes prior to startup of an idle recirculation loop.

M4 The CTS does not provide any actions to be taken if a P/T limit is not met in MODES other than MODES 3.4.9 ACTION C N/A 1, 2, and 3. The ITS includes a new action that requires action be initiated immediately to restore the parameters to within limits and to determine, prior to entering MODE 2 or 3, whether the RCS is acceptable for continued operation.

CTS 3/4.6.F, STRUCTURAL INTEGRITY NONE NONE NONE NONE PAGE 5 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM 3.51.FCCS - OPERATING M1 The CTS permits up to 10 days of continuous operation from the time steam becomes available until SR 3.5.1.8 4.5.C HPCI Surveillances need to be performed. The Notes to the applicable ITS Surveillances will allow only Note, SR 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> from the time reactor steam pressure and flow are adequate to perform the test. The 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 3.5.1.9 Note, is deemed to be adequate to perform the testing involved without impacting plant operation.

SR 3.5.1.10 Note 1 M2 The CTS requires that HPCI deliver at least 4,250 gpm (modified by DOC L7) is being divided into two SR 3.5.1.8, SR 4.5.C.1 separate Surveillance Requirements. The first ITS Surveillance will require a demonstration of the HPCI 3.5.1.9 pump capability at nominal conditions (970 to 1040 psig in the reactor steam dome). Reactor pressures of > 970 psig and < 1040 psig represents a nominal value at rated conditions within the CTS required band for testing. This pressure range represents conditions of lower driving pressure for the HPCI turbine and thus, a more restrictive condition under which to provide the required flow. The second ITS Surveillance will require a demonstration of the HPCI pump capability ! 165 psig. Reactor pressure of <

165 psig is near the lower limit (i.e., Ž 150 psig) of operability/capability of the HPCI turbine, yet provides a 15 psig range above the lower limit in which to conduct the test. CTS required that the HPCI test confirm the capability of the pump at 150 psig. As a practical consideration, the test is performed when sufficient pressure is available at near 150 psig. To require the test at

  • 150 psig would be to require a test of the capability of the pump outside the required operability range.

M3 The CTS requires that at least 5 of the 7 ADS valves be Operable. The ITS requires that at least 6 of the LCO 3.5.1. 3.5.1 3.5.D.1 ADS valves be Operable. The proposed change also adds two Actions that do not exist in the CTS. The ACTIONS E and first Action contains requirements for what to do if one of the six required ADS valves is inoperable. The F

Action allows up to 14 days to restore the inoperable ADS valve. The second ACTION limits continued reactor operation to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> when there is a simultaneous inoperability of one required ADS valve (one of the six required ADS valves) and one low pressure ECCS (CS or LPCI) subsystem or one LPCI pump inoperable in each subsystem. These requirements are more restrictive because current requirements would allow continued plant operation under the same conditions.

PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M4 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.5.1 Required 3.5.A.6 ACTIONS or Completion Times associated with an inoperable LPCI or CS System cannot be satisfied, Actions B.1 and 3.5.C.1.6 when the ACTIONS associated with an inoperable HPCI or ADS System cannot be satisfied, and when G.1 3.5.D.2 both LPCI independent power supplies are made or found to be inoperable. This specific default action 3.9.F.3 has been interpreted to also require entry when the ACTIONs or Completion Times associated with one inoperable LPCI independent power supply are not met since no other exists. In the ITS, an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M5 The CTS requires that recirculation pump discharge valves be demonstrated Operable (capable of being SR 3.5.1.6 4.5.A.5 closed) following "any period of reactor cold shutdown exceeding 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />". This requirement is proposed to be replaced in the ITS by a Surveillance that requires that recirculation pump discharge valve Operability verification be performed once each startup prior to exceeding > 25% RTP.

Recirculation pump discharge valves are not required while the plant is shutdown. The requirement to perform the verification once each startup prior to exceeding 25% RTP is more restrictive than the existing requirement to perform the test since the test will now be required to be performed within 31 days of any startup not just a startup from a Cold Shutdown that exceeded 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />._-A M6 A new requirement to verify the ADS pneumatic supply header pressure has been added to the ITS.

SR 3.5.1.3 N/A M7 A new requirement to verify that each inverter output voltage is Ž 576 V and _< 624 V while supplying the SR 3.5.1.5 4.9.F.7 respective bus has been added.

M8 The CTS states that the reactor shall not be made critical unless both LPCI MOV Independent Power 3.5.1 3.9.F.1 Supplies are operable. This is effectively MODES 1 and 2. The ITS requires the low pressure core Applicability injection subsystems to be Operable in MODES 1, 2 and 3. Since the operability of the LPCI MOV Independent Power Supply affects the OPERABILITY of the associated LPCI subsystem, the operability requirements of LPCl MOV Independent Power Supplies have been extended to MODE 3.

M9 The CTS requires the safety/relief valves to be manually opened every 24 months. The ITS requires this SR 3.5.1.13 4.6.E.4 same manual opening, but also requires the actuation to be initiated on a Staggered Test Basis for each valve solenoid._This will ensure that both solenoids will be tested every 48_months.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M10 The CTS requires all recirculation pump discharge valves to be Operable prior to reactor startup (or SR 3.5.1.6 3.5.A.5 closed if permitted elsewhere in these specifications). The ITS and associated Surveillance Requirement also require all recirculation pump discharge valves to be Operable. However, if this requirement can not be met, then the Surveillance requires the associated recirculation pump discharge valve to be "de energized" in the closed position. Requiring the inoperable recirculation pump discharge valve to also be "de-energized"_in the closed position represents an additional restriction on plant operation.

Ml1l The CTS requires the HPCI System discharge piping to be vented from the high point of the system SR 3.5.1.1 4.5.G.3 whenever HPCI is lined up to take suction from the condensate storage tank (CST) on a monthly basis.

In the ITS, this requirement must be met whenever HPCI is required to be Operable whether it is aligned to theCST or the suppression pool.

M12 CTS 3.5.A.1 and 3.5.A.3 require the Core Spray (CS) and Low Pressure Coolant Injection (LPCI) 3.5.1 3.5.A.1, Systems, respectively to be Operable whenever irradiated fuel is in the reactor vessel and prior to reactor Applicability 3.5.A.3, startup from cold shutdown (this covers MODES 1, 2 in the ITS). CTS 3.5.A specifies requirements for 3.5.A.3.b, the LPCI cross tie valves whenever reactor water temperature is greater than 212°F (this covers MODES 3.5.A.5 1, 3, and portions of MODE 2 operations). In addition, CTS 3.5.A.5 specifies requirements for the recirculation pump discharge valves prior to reactor startup (this covers MODE 1 and 2 in the ITS). The ITS Applicability for these components and Systems (Applicability of ITS 3.5.1) are MODES 1, 2 and 3.

This change is more restrictive since the Applicability of all portions of the CS and LPCI subsystems have been changed to cover all three plant operating modes.

M13 An actual or simulated automatic isolation test has been added to the requirements of CTS Table 4.2-2 SR 3.5.1.10 N/A Item 3 (Part 2) (Containment Cooling Subsystem) to ensure both a Logic System Functional Test as well as an actual or simulated automatic isolation test is performed for all associated Low Pressure Coolant Injection (LPCI) System Functions currently included in Table 3.2-2 and 4.2-2. The new Surveillance will ensure CTS Table 3.2-1 Items 5 and 6 ( ITS Table 3.3.5.1-1 Functions 2.e and 2.h, Reactor Vessel Shroud Level (Level 0) and Containment Pressure - High) are properly tested throughout their operating sequence.

3.5.2, ECCS - SHUTDOWN JAFNPP PAGE 3

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M1 CTS 3.5.F.4 requires the Secondary Containment Integrity to be established within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> if any of the 3.5.2 Required 3.5.F.4 other actions in CTS 3.5.F.4 are not met (e.g., suspend OPDRVs, restore at least one ECCS low Actions D.1, pressure injection/spray subsystem to Operable status). If Secondary Containment Integrity is not D.2, and D.3 established, no other actions are provided. The ITS requires similar a similar action to establishing Secondary Containment Integrity (as modified by DOC A4), except that in lieu of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to establish Integrity, the action is to "initiate action." This will ensure actions are continued to establish secondary containment integrity, even is not established within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

M2 The CTS permits both Core Spray (CS) subsystems to be considered operable in MODES 4 and 5 when SR 3.5.2.2.b 4.5.F.4 the subsystems are taking a suction from the CSTs. The ITS allows only one CS subsystem to be Note considered operable when taking a suction from the CSTs during operations with the potential for draining the vessel (OPDRVs).

M3 CTS 3.5.F.3 provides an exception to the ECCS low pressure applicability requirements in CTS 3.5.F.1 3.5.2 3.5.F.3 and 3.5.F.2 whenever the reactor vessel head is removed, the cavity is flooded, the spent fuel gates are Applicability removed and water level above the fuel is in accordance with CTS 3.10.C. CTS 3.10.C requires the level to be 33 feet above the bottom of the spent fuel storage pool. The corresponding Applicability of the ITS is MODE 5, except with the spent fuel storage gate removed and the reactor vessel water level _> 22 ft 2 inches above the top of the reactor vessel flange. This corresponds to an increase of over 4 ft from the CTS requirement.

M4 The CTS requires the suspension of all operations with the potential for draining the vessel (OPDRV) 3.5.2 Required 3.5.F.4 when the requirements of CTS 3.5.F.1, 3.5.F.2 or 3.5.F.3 are not satisfied. However, a completion time Action C.1 is not specified._TheITS is explicit and requires to initiate action to suspendOPDRVs immediately.

3.5.3, RCIC SYSTEM M1 The CTS requires the reactor to be placed in a cold condition (MODE 4) and pressure less than 150 psig 3.5.3 Required 3.5.E.2 within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the ACTIONS or Completion Times associated with the inoperable RCIC System Action B.1 cannot be satisfied. In the ITS, an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

PAGE 4 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.5 - ECCS AND RCIC SYSTEM DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS permits up to 10 days of continuous operation from the time steam becomes available until SR 3.5.3.3 4.5.E.1 RCIC Surveillances need to be performed. The Notes to the applicable ITS Surveillances will allow only Note, SR 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> from the time reactor steam pressure and flow are adequate to perform the test. The 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> 3.5.3.4 Note, is deemed to be adequate to perform the testing involved without impacting plant operation.

SR 3.5.3.5 Note 1

M3 The CTS requires that RCIC deliver at least 400 gpm is being divided into two separate Surveillance SR 3.5.3.3, SR 4.5.E.1.d Requirements. The first ITS Surveillance will require a demonstration of the RCIC pump capability at 3.5.3.4 nominal conditions (970 to 1040 psig in the reactor steam dome). Reactor pressures of ? 970 psig and

  • 1040 psig represents a nominal value at rated conditions within the CTS required band for testing.

This pressure range represents conditions of lower driving pressure for the RCIC turbine and thus, a more restrictive condition under which to provide the required flow. The second ITS Surveillance will require a demonstration of the RCIC pump capability

  • 165 psig. Reactor pressure of
  • 165 psig is near the lower limit (i.e., 2 150 psig) of operability/capability of the RCIC turbine, yet provides a 15 psig range above the lower limit in which to conduct the test. CTS required that the RCIC test confirm the capability of the pump at 150 psig. As a practical consideration, the test is performed when sufficient pressure is available at near 150 psig. To require the test at
  • 150 psig would be to require a test of the capability of the pump outside the required operability range.

M4 The CTS requires the RCIC System discharge piping to be vented from the high point of the system SR 3.5.3.1 4.5.G.3 whenever RCIC is lined up to take suction from the condensate storage tank (CST) on a monthly basis.

In the ITS, this requirement must be met whenever RCIC is required to be Operable whether it is aligned to the CST or the suppression pool.

M5 Not used.

N/A N/A M6 Not used.

N/A N/A PAGE 5 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS

SUMMARY

Sr -I -I D MII AIV Y

'1TAINM*

I T

6.1.

  • . Ib

.1 I r1, llV I

T I11

.IF

-I m I

M1 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.1.1 3.7.A.8 Primary Containment is inoperable. In the ITS (after a short restoration time as discussed in DOC L1),

Required an intermediate condition,_MODE_3,_must be met within_12_hours.

Action B.1 M2 The CTS requires the drywell to suppression chamber leak rate to be verified. The ITS includes a new SR 3.6.1.1.2 N/A requirement that if two consecutive leak tests fail, the leak test must be repeated every 12 months until second two consecutive leak tests pass. Two consecutive test failures would indicate unexpected primary Frequency containment degradation, and increasing the Frequency to once every 12 months establishes the acceptability of the drywell to suppression chamber leakage sooner.

M3 The CTS Applicability of the Primary Containment is whenever the reactor is critical or when the reactor 3.6.1.1 3.7.A.2 water temperature is above 212 OF and fuel is in the reactor vessel. The Applicability in the ITS is Applicability MODES 1, 2 and 3, which adds a new Applicability requirement that the Primary Containment must be Operable at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below 212 OF.

M4 The CTS requirement that the drywell to suppression chamber leak rate test be conducted at 1 psid is SR 3.6.1.1.2 4.7.A.5.d being changed to a differential pressure of Ž 1 psi.

3.6.1.2, PRIMARY CONTAINMENT AIR LOCKS M1 The CTS requirement that requires at least one door in each air lock is closed and sealed is being LCO 3.6.1.2, 3.7.A.2, 1.0.M revised to require both air lock doors be OPERABLE in the ITS. In addition, appropriate ACTIONS have 3.6.1.2 been added for when one of the two doors is inoperable.

ACTION A M2 A New Surveillance Requirement has been added to verify that only one door in the primary 3.6.1.2 N/A containment air lock can be opened at a time. In addition, a new ACTION has been added to cover the ACTION B, SR case when an interlock mechanism is inoperable. Currently, the CTS does not require the interlock 3.6.1.2.2 rmechanism to beOperable.

PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M3 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.1.2 3.7.A.8 Primary Containment Air Lock(s) is inoperable. In the ITS (after the appropriate restoration times as Required discussed in DOCs M1, M2, and L3), an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Action D.1 M4 The CTS Applicability of the Primary Containment Air Locks is whenever the reactor is critical or when 3.6.1.2 3.7.A.2 the reactor water temperature is above 212 OF and fuel is in the reactor vessel. The Applicability in the Applicability ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the Primary Containment Air Locks must be Operable at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below 212 °F.

3.6.1.3, PRIMARY CONTAINMENT ISOLATION VALVES M1 The CTS Applicability of the Primary Containment Isolation Valves is whenever the reactor is critical or 3.6.1.3 3.7.D.1 when the reactor water temperature is above 212 OF and fuel is in the reactor vessel. The Applicability Applicability, in the ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the Primary 3.6.1.3 Containment Isolation Valves must be Operable at all times in MODE 2 even prior to any plant startup ACTION G when reactor coolant temperature may be below 212 OF. In addition, the ITS includes an Applicability of "When associated instrumentation is required to be OPERABLE per LCO 3.3.6.1, "Primary Containment Isolation Instrumentation."" This effectively adds a MODES 4 and 5 requirement for the RHR SDC isolation valves. Due to this addition, a new ACTION has been added for these valves.

M2 The CTS surveillance that tests for proper operation of the instrument line EFCVs does not include an SR 3.6.1.3.8 4.7.D.1.b acceptance criteria. The ITS specifies an acceptance criteria that the EFCVs actuate to the isolation position on a simulated instrument line break.

M3 The CTS surveillance that tests and times the closure of the MSIVs does not include a closure time.

SR 3.6.1.3.6 4.7.D.1.d TheITS specifies anMSIV closure time of > 3 seconds and < 5 seconds._I_

I

_I PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M4 The ITS includes four new Surveillance Requirements to a) verify (each 31 days) each PCIV manual SR 3.6.1.3.2, N/A isolation valve, or blind flange that is located outside of primary containment and not locked, sealed or SR 3.6.1.3.3, otherwise secured and is required to be closed during accident conditions is closed; b) verify (prior to SR 3.6.1.3.4, entering MODE 2 or 3 from MODE 4 if primary containment was de-inerted while in MODE 4, if not SR 3.6.1.3.9 performed within the previous 92 days) each PCIV manual isolation valve, or blind flange that is located inside of primary containment and not locked, sealed or otherwise secured and is required to be closed during accident conditions is closed; c) verify (each 31 days) continuity of the traversing incore probe (TIP) shear isolation valve explosive charge; and d) remove and test (each 24 months on a STAGGEREDTESTBASIS)_the explosive squib from each shear isolation valve of theTipSystem.

M5 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.1.3 3.7.D.3 Primary Containment Isolation Valves are not restored to Operable status within certain time limits. In Required the ITS (after the appropriate restoration times), an intermediate condition, MODE 3, must be met within Action F.1 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M6 The CTS requires that LPCI and Core Spray Systems air operated testable check valves to be leak SR 3.6.1.3.11 4.7.A.2.c tested, with the limit

  • 11 scfm per valve when pneumatically tested at >_ 45 psig at ambient temperature.

The pneumatic test limit is being decreased to : 10 scfm as shown in the Bases for the applicable SR (limits moved to Bases as described in DOC LAl).

M7 The CTS requirement that 27MOV-1 20 (the 12 inch, full-flow valve) be verified closed when containment SR 3.6.1.3.1, 3.7.B.4, integrity is established, and then once per month, is being replaced in the ITS with a requirement to including Note 4.7.B.4 verify that each 20 and 24 inch primary containment purge and vent valve is closed every 31 days, since the purge and vent valves are the actual primary containment isolation valves (PCIVs) associated with these penetrations. In addition, the CTS allows inerting and de-inerting operations only with valve 27MOV-121 (the 6 inch, low flow valve), it is understood that the primary containment purge and vent valves must be opened for these operations. Therefore, the ITS includes a Note that allows these operations to occur as long as the full-flow line (27MOV-120) is closed and one or more SGT System reactor building suction valves are open. This provides protection for the SGT filter trains from over pressure concerns. This change is considered more restrictive since the primary containment vent and purge valves are required to be closed when these operations are not underway.

3.6.1.4, DRYWELL PRESSURE PAGE 3 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 A new Specification requiring drywell pressure to be < 1.95 psig is included in the ITS, consistent with 3.6.1.4 N/A the accident analysis assumptions. Appropriate ACTIONS and a Surveillance Requirement have also been added.

3.6.1.5, DRYWELL AIR TEMPERATURE M1 A new Specification requiring drywell air temperature to be < 1350F is included in the ITS, consistent 3.6.1.5 N/A with the accident analysis assumptions. Appropriate ACTIONS and a Surveillance Requirement have also been added.

3.6.1.6, REACTOR BUILDING-TO-SUPPRESSION CHAMBER VACUUM BREAKERS M1 The CTS allows 7 days to restore an inoperable reactor building-to-suppression chamber vacuum 3.6.1.6 3.7.A.4.b breaker provided primary containment integrity is maintained. In the ITS, restoration is required within ACTION A 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

and C M2 A new Surveillance Requirement has been added to verify that the reactor building-to-suppression SR 3.6.1.6.1 N/A chamber vacuum breakers are closed.

M3 A new Surveillance Requirement has been added to verify that the reactor building-to-suppression SR 3.6.1.6.4 N/A chamber self actuating vacuum breakers are capable of opening at a differential pressure of

  • 0.5 psid.

M4 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.1.6 3.7.A.8 Required Actions and associated Completion Times for an inoperable reactor building-to-suppression Required chamber vacuum breaker is not met or when two vacuum breakers are inoperable. In the ITS (after the Action E.1 appropriate restoration times), an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M5 The CTS requires a functional test of the instrumentation associated with the suppression chamber-SR 3.6.1.6.3 4.7.A.4.b reactor building vacuum breakers every 92 days, and also requires the setpoint to be at < 0.5 psi. The 3.7.A.4.a ITS requires a CALIBRATION (instead of a function test) of each air operated vacuum breaker differential pressure instrument channel, including a verification that the setpoint is < 0.5 psid. This

_change is more restrictive since it will require a complete check of each instrument loop and the sensor.

PAGE 4 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M6 The CTS Applicability of the reactor building-to-suppression chamber vacuum breakers is whenever the 3.6.1.6 3.7.A.4.a reactor is critical or when the reactor water temperature is above 212 OF and fuel is in the reactor vessel.

Applicability 3.7.A.2 The Applicability in the ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the reactor building-to-suppression chamber vacuum breakers must be Operable at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below 212 OF.

M7 The CTS identifies that two reactor building-to-suppression chamber vacuum breakers shall be LCO 3.6.1.6, 3.7.A.4.a, OPERABLE. The ITS LCO requires each of the two vacuum breakers (the self actuated valve and the 3.6.1.6 3.7.A.4.b air operated valve) in each of the two vacuum relief lines shall be OPERABLE. The CTS identifies the ACTIONS A,B, Required Actions if one reactor building-to-suppression chamber vacuum breaker is inoperable (without C, and D specifying whether the vacuum relief or the containment isolation function of the valve is inoperable).

The CTS has been modified to specifically address inoperability of the containment isolation function of one vacuum breaker valve. If more than one vacuum breaker is inoperable (or the actions and associated completion times are not met), the default action of the CTS must be entered which requires the reactor be placed in the cold condition within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

The CTS has been modified by providing additional more restrictive actions that specifically address the inoperability of containment isolation functions and vacuum relief of the vacuum breaker valves in each of the vacuum relief lines. The ITS ACTIONS: a) addresses inoperability of the containment isolation function of two (both) vacuum breakers in a line and consistent with ITS 3.6.1.3, ACTION B, 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is allowed to correct the loss of containment capability; b) addresses the inoperability of the vacuum relief function of one vacuum relief line due to one or more vacuum breaker valves in the line not being capable of opening (while the vacuum relief function is maintained by the vacuum relief valves in the other line) and 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is allowed to correct the condition; and c) addresses loss of the vacuum relief function of two (both) vacuum relief lines and 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is allowed to correct the condition.

3.6.1.7, SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS M1 A new Surveillance Requirement has been added to verify that each suppression chamber-to-drywell SR 3.6.1.7.1 N/A vacuum breaker is closed everyn14 days.

M2 The CTS allows 7 days to restore an inoperable suppression chamber-to-drywell vacuum breaker. In 3.6.1.7 3.7.A.5.c, the ITS, restoration is required within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

ACTION A 3.7.A.5..q PAGE 5 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M3 The CTS requires an inoperable vacuum breaker (i.e., an open vacuum breaker) to be locked closed; 3.6.1.7 3.7.A.5.g however no specific time is provide to close the vacuum breaker. The ITS will require the open vacuum ACTION B breaker to be closed within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The requirement to lock the vacuum breaker closed is not included in the ITS, since once the open vacuum breaker is closed, it is now considered Operable.

M4 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.1.7 3.7.A.8 Required Actions and associated Completion Times for an inoperable suppression chamber-to-drywell Required vacuum breaker is not met. In the ITS (after the appropriate restoration times), an intermediate Action C.1 condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M5 The CTS Applicability of the suppression chamber-to-drywell vacuum breakers is whenever the reactor 3.6.1.7 3.7.A.4.a is critical or when the reactor water temperature is above 212 IF and fuel is in the reactor vessel. The Applicability Applicability in the ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the suppression chamber-to-drywell vacuum breakers must be Operable at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below_212_'F.

3.6.1.8, MAIN STEAM LEAKAGE COLLECTION (MSLC) SYSTEM M1 A new Specification requiring two MSLC subsystem to be Operable is included in the ITS, consistent 3.6.1.8 N/A with the accident analysis assumptions. Appropriate ACTIONS and Surveillance Requirements have also been added.

3.6.1.9, RHR CONTAINMENT SPRAY M1 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.1.9 3.5.B.4 Required Actions and associated Completion Times for an inoperable RHR containment spray Required subsystem is not met. In the ITS (after the appropriate restoration times), an intermediate condition, Action C.1 MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M2 The CTS requires a pump operability and flow rate test, but no acceptance criteria is provided. The ITS SR 3.6.1.9.2 4.5.B.1.a includes a specific flow rate and flow path.

PAGE 6 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS

SUMMARY

ITS SECTION CTS SECTION 3.6.2.1, SUPPRESSION POOL AVERAGE TEMPERATURE The ITS includes a new action to verify temperature is < 110 OF once per hour when the temperature has exceeded 95 OF and no testing that adds heat to the suppression pool is being pyrt oIuI,,u.

The ITS includes new actions if the temperature is> 110 OF. In addition to requiring a reactor scram (which is consistent with the CTS requirements), the ITS will require suppression pool temperature to be verified < 120 OF once per 30 minutes and that the reactor be placed in MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

The CTS requires that, during reactor isolation conditions, the reactor pressure vessel be depressurized to less than 200 psig if pool temperature reaches 200 OF. The ITS requires the depressurization action regardless of whether or not the reactor is isolated. In addition, the ITS requires the depressurization to 200 psig to be completed within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and for the plant to be in MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

The CTS Applicability of the suppression pool average temperature is whenever the reactor is critical or when the reactor water temperature is above 212 OF and fuel is in the reactor vessel.

The Applicability in the ITS is MODES 1, 2 and 3, which adds a new Applicability requirement that the suppression pool average temperature must be within limits at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below 212 OF.

3.6.2.1 Required Action A.1 3.6.2.1 Required Actions D.2 and D.3 3.6.2.1 ACTION E 3.6.2.1 Applicability I.1_

_I_

N/A N/A 3.7.A.1.c.(4) 3.7.A.1 3.6.2.2, SUPPRESSION POOL WATER LEVEL M1 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.2.2 3.7.A.8 suppression pool water level limits are not met. In the ITS (after the appropriate restoration time as Required modified by DOC LI) 1an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Action B.1 PAGE 7 JAFNPP DOC #

M1 M2 M3 M4 I

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS Applicability of the suppression pool water level is whenever the reactor is critical or when the 3.6.2.2 3.7.A.1 reactor water temperature is above 212 OF and fuel is in the reactor vessel. The Applicability in the ITS Applicability is MODES 1, 2 and 3, which adds a new Applicability requirement that the suppression pool water level must be within limits at all times in MODE 2 even prior to any plant startup when reactor coolant temperature may be below_212_OF.

3.6.2.3, RHR SUPPRESSION POOL COOLING M1 The CTS requires a pump operability and flow rate test, but no acceptance criteria is provided. The ITS SR 3.6.2.3.2 4.5.B.1.a includes a specific flow rate and flow path.

M2 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.2.3 3.5.B.4 Required Actions and associated Completion Times for an inoperable RHR suppression pool cooling Required subsystem is not met. In the ITS (after the appropriate restoration times), an intermediate condition, Action C.1 MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

3.6.2.4, DRYWELL-TO-SUPPRESSION CHAMBER DIFFERENTIAL PRESSURE NONE NONE NONE NONE 3.6.3.1, PRIMARY CONTAINMENT OXYGEN CONCENTRATION NONE NONE NONE NONE 3.6.3.2, CAD SYSTEM PAGE 8 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 A new Specification requiring two CAD subsystems to be Operable is included in the ITS, consistent 3.6.3.2 N/A with the accident analysis assumptions. Appropriate ACTIONS and a Surveillance Requirement have also been added.

3.6.4.1, SECONDARY CONTAINMENT M1 The ITS includes an additional Applicability, during operations with a potential for draining the reactor 3.6.4.1 3.7.C.1 vessel. An appropriate ACTION has also been added.

Applicability, 3.6.4.1 Condition C, 3.6.4.1 Required Action C.3 M2 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.4.1 3.7.C.2 Secondary Containment is inoperable. In the ITS (after a short restoration time as discussed in DOC Required

-Li), an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Action B.1 M3 The CTS requires that if the Secondary Containment is inoperable, procedures shall be initiated to 3.6.4.1 3.7.C.2 suspend activity that can reduce the shutdown margin and movement of irradiated fuel in the reactor Required building; however, no specific time limit to start or complete the actions is provided. The ITS will require Actions C.1 and immediate suspension of these activities.

C.2 M4 The CTS requires a demonstration of the secondary containment capability to maintain 1/4 inch of water SR 3.6.4.1.4 4.7.C.1.c vacuum in the secondary containment; however, no specific time duration for the test is provided. The ITS requires the test to be conducted for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

M5 The CTS requires a demonstration of the secondary containment capability to maintain 1/4 inch of water SR 3.6.4.1.4 4.7.C.1.c vacuum in the secondary containment using one filter train; however the test does not require testing the capability of both SGT trains. One SGT train could be used to perform the test over the life of the plant.

The ITS requires the use of both SGT trains on a staggered test basis (i.e., each SGT train will be tested I_ every two ref ueling outage cycles).

PAGE 9 JAFNPP

"TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M6 A new Surveillance Requirement is being added to verify that the secondary containment vacuum is >

SR 3.6.4.1.1 N/A 0.25 inches water gauge every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

M7 A new Surveillance Requirement is being added to verify all secondary containment hatches are closed SR 3.6.4.1.2 N/A and sealed every 31 days.

M8 A new Surveillance Requirement is being added to verify one secondary containment access door is SR 3.6.4.1.3 N/A closed in each access opening every 31 days._I 3.6.4.2, SECONDARY CONTAINMENT ISOLATION VALVES M1 The CTS only requires the automatic dampers to be Operable. The ITS requires all secondary LCO 3.6.4.2, 1.0.S.3 containment isolation valves, which includes manual valves and blind flanges to be Operable In ACTIONS A, B, addition, appropriate ACTIONS for these valves have also been added.

C, and D M2 The ITS includes an additional Applicability, during operations with a potential for draining the reactor 3.6.4.2 3.7.C.1 vessel. An appropriate ACTION has also been added.

Applicability, 3.6.4.2 Required Action D.3 M3 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.6.4.2 N/A Secondary Containment isolation Valves are inoperable. In the ITS (after a short restoration time as Required discussed in DOCs L3 and L4), an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Action C.1 M4 The CTS requires that if the Secondary Containment isolation valves are inoperable, procedures shall 3.6.4.2 3.7.C.2 be initiated to suspend activity that can reduce the shutdown margin and movement of irradiated fuel in Required the reactor building; however, no specific time limit to start or complete the actions is provided. The ITS Actions D.1 and will require immediate suspension of these activities.

D.2 M5 The ITS includes an additional action when a secondary containment valve is inoperable and the 3.6.4.2 N/A associated penetration has been isolated. The ITS will require a verification that the penetration is Required isolated every 31 davs.

Action A.2 PAGE 10 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M6 A new Surveillance Requirement has been added to verify each SCIV actuates to the isolation position SR 3.6.4.2.3 N/A on an actual or simulated Refuel Area Exhaust Monitor signal.

M7 A new Surveillance has been added to verify, every 31 days, that each secondary containment isolation SR 3.6.4.2.1 N/A manual valve and blind flange that is not locked, sealed, or otherwise secured and is required to be closed during accident conditions is closed.

M8 A new Surveillance Requirement has been added to verify the isolation time of each power operated SR 3.6.4.2.2 N/A automaticSCIV is within limits every_92_days.

3.6.4.3, SGTSYSTEM M1 The ITS includes an additional Applicability, during operations with a potential for draining the reactor 3.6.4.3 N/A vessel. An appropriate ACTION has also been added.

Applicability, 3.6.4.3 Conditions C and E, 3.6.4.3 Required Actions C.2.3 and E.3 M2 The CTS allows 31 days to restore a SGT subsystem when one is inoperable during refuel or cold 3.6.4.3 3.7.B.2.b shutdown. The ITS will only allow 7 days to restore the inoperable SGT subsystem.

ACTION A M3 The CTS requires the reactor to be placed in a cold condition (MODE 4) when the inoperable SGT 3.6.4.3 3.7.B.3 subsystem is not restored to Operable status within the allowed time; however, no time limit is provided ACTION B for placing the plant in MODE 4. In the ITS, a 36 hour4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> time limit is provided, and an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />._I_

1_1_

JAFNPP PAGE 11

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS PAGE 12 JAFNPP

SUMMARY

ITS SECTION CTS SECTION The CTS requires the reactor to be placed in a cold condition (MODE 4) when both SGT subsystems 3.6.4.3 3.7.B.3 are inoperable while in MODE1, 2, or 3; however, no time limit is provided for placing the plant in MODE ACTION D

4. In the ITS, an entry into LCO 3.0.3 will be required, which will require action to be initiated within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to place the plant in MODE 2 within 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />, MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, and MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M5 3.6.4.3 Required Action C Note, 3.6.4.3 Required Action E.1 Note 3.7.B.3 When the requirements of CTS 3.7.B.1 (both SGT subsystems required to be Operable) or 3.7.B.2 (plant operation is allowed to continue for a limited time period with one inoperable SGT subsystem provided the redundant SGT subsystem is verified Operable) cannot be met, CTS 3.7.B.3 requires an immediate plant shutdown and the suspension of fuel handling operations. If CTS 3.7.B.3 cannot be met, entry into CTS 3.O.C is permitted and the plant must be in COLD SHUTDOWN within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Therefore, if the plant is operating in MODE 1, 2, or 3 and also handling fuel in the secondary containment, the CTS will require the plant to shutdown but not necessarily require the suspension of fuel handling since the default action (CTS 3.0.C) does not address suspension of fuel handling operations. Similarly, if CTS 3.7.B.3 can not be met during fuel handling operations while the plant is shutdown, default to CTS 3.0.C would not require any action to be taken since the plant would have previously been shutdown and suspension of fuel handling is not required by CTS 3.0.C.

In ITS 3.6.4.3, if one SGT subsystem is inoperable and not restored to an Operable status within the allowed time (ITS 3.6.4.3, Required Action A.1 and associated Completion Time), while operating in MODE 1, 2, or 3 during fuel handling operations, ITS 3.6.4.3 ACTION B requires a plant shutdown and ITS 3.6.4.3, CONDITION C is concurrently applicable and ACTION C Note does not allow default to ITS 3.0.3 (since default to ITS 3.0.3 would allow Required Action C.1 (or Actions C.2.1, C.2.2, and C.2.3) to be bypassed). Therefore, the proposed addition of ITS 3.6.4.3, ACTION C Note, is an additional restriction that requires that the activities addressed in Required Action C.1 (or Required Actions C.2.1, C.2.2, and C.2.3) be taken rather than be bypassed by defaulting to ITS 3.0.3. In a similar manner, if the Required Actions and Completion Time of ACTION A can not be met during fuel handling operations while shutdown (MODE 4 or 5), the addition of proposed ITS 3.6.4.3, ACTION C Note does not allow default to ITS 3.0.3 and thus is a restriction that is not contained in CTS. In addition ITS 3.6.4.3, Required Action E.1 requires the immediate suspension of movement of irradiated fuel assemblies in the secondary containment, if both SGT subsystems are inoperable. The proposed addition of the Note to CTS 3.7.B.3 (ITS 3.6.4.3 Required Action E.1 Note), which states that LCO 3.0.3 is not applicable, is also a more restrictive change that requires the suspension of irradiated fuel handling operations since default to ITS 3.0.3 is not allowed.

Addition of the Note to ITS 3.6.4.3, ACTION C and Required Action E.1, provides clarification and is necessary because although defaulting to LCO 3.0.3 would require the reactor to be shutdown it would not require the suspension of the activities with the potential for releasing radioactive material to the secondary containment. Not allowing LCO 3.6.4.3, ACTION C, and Required Action E.1 to be bypassed by entry in LCO 3.0.3 ensures the suspension of these activities will be addressed, thus placing the plant in a condition that minimizes risk. Therefore, this change is more restrictive but necessary to minimize the Drobabilitv of release when the secondary containment is not Operable.

I I

I

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.6 - CONTAINMENT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M6 A new Surveillance Requirement is being added to operate each SGT subsystem for_> 10 continuous SR 3.6.4.3.1 N/A hours with heaters operating every 31 days.

CTS 3.7.A.3, CONTAINMENT PURGE THROUGH THE STANDBY GAS TREATMENT SYSTEM NONE NONE NONE NONE PAGE 14 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS

SUMMARY

q71 RRS YSE

  • .5. 1.

1 I

) I lI 0III 1.FI 1V V

M1 The CTS requires the reactor to be placed in a cold condition (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 3.7.1 Required N/A ACTIONS or Completion Times associated with inoperable RHRSW pump(s)/subsystem(s) cannot be Action E.1 satisfied. In the ITS, an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M2 The CTS allows 7 days of operation with RHR service water subsystem inoperable. The ITS includes a 3.7.1 Required N/A Note that would require the applicable Conditions and Required Actions of ITS 3.4.7, "RHR Shutdown Action C.1 Cooling System - Hot Shutdown" to be entered for an RHR SDC subsystem made inoperable by the Note inoperable RHR Service Water System. This Note is an exception to proposed LCO 3.0.6, which ensures proper ACTIONS are taken for RHR shutdown cooling.

3.7.2, ESW SYSTEM and UHS M1 The CTS requires the reactor to be placed in a cold condition within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the ACTIONS or 3.7.2 Required N/A Completion Times associated with inoperable ESW subsystem(s) or inoperable deicing heater(s)

Action C.1 cannot be satisfied. In the ITS, an intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />._

_1 M2 Two Surveillance Requirements have been added to verify the water level in each ESW pump SR 3.7.2.1, SR N/A screenwell (ensuring that adequate level for ESW pump submergence exists) and to verify the Ultimate 3.7.2.2 Heat Sink temperature (ensuring the temperature of water to the required coolers is consistent with analyses).

M3 The CTS requires a minimum of 18 out of 88 heaters to be operable to maintain required flow for the 3.7.2.4 3.11.E ESW and RHRSW Systems. This requirement is not explicit as to whether heaters in both divisions are 3.7.2.5 required. The ITS requires (in the Bases) that 18 heaters associated with each division are required to 3.7.2.6 beOperable,_for a total of_36_heaters.

3.7.3, CREVAS SYSTEM JAFNPP PAGE 1

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The CTS requires both of the control room emergency ventilation air supply fans and fresh air filter 3.7.3 3.11.A.1 trains to be available whenever the reactor coolant is greater than 212OF and when fuel is handled.

Applicability The ITS Applicability is during MODES 1, 2 and 3, during the movement of irradiated fuel assemblies in the secondary containment, during CORE ALTERATIONS and during operations with a potential of draining the reactor vessel (OPDRVs). The ITS Applicability covers additional modes of operation.

M2 The CTS requires each control room emergency ventilation air supply fans and dampers to be tested SR 3.7.3.1 4.11.A.1 for operability every 3 months; no time duration is specified for the test. The ITS requires the operation of each CREVAS subsystem every 92 days for a time period of greater than or equal to 15 minutes, where each CREVAS subsystem includes testing of the air handling unit fans and recirculation exhaust fans in addition to the air supply booster fans and dampers.

M3 The CTS allows one emergency ventilation air supply fan and or filter (CREVAS subsystem) to be 3.7.3 3.11.A.1 inoperable for 14 days. After this 14 day period, CTS 3.0.C must be entered since no specific default ACTIONS A, action exists in the CTS; therefore the plant must be placed in COLD SHUTDOWN within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

C, and D The ITS limits the time one CREVAS subsystem can be inoperable to 7 days, and then, if the unit is in MODES 1, 2, or 3, requires a shutdown to MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. If the plant is moving irradiated fuel in the secondary containment, performing CORE ALTERATIONS, or performing OPDRVs, then the ITS will require the immediate placement of the OPERABLE subsystem in the isolate mode of operation or to immediately suspend movement of irradiated fuel assemblies in the secondary containment, immediately suspend CORE ALTERATIONS and to immediately initiate action to suspend OPDRVs. A Note has been included to proposed ACTION D), which provides an exception to CTS 3.0.C (ITS LCO 3.0.3) if the Required Actions can not be met. This clarification was necessary because defaulting to LCO 3.0.3 would require the reactor to be shutdown but would not require the suspension of the activities that have the potential for releasing radioactivity that might require isolation of the control room and operation of CREVAS in the isolate mode.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M4 The CTS allows reactor or refueling operations to continue for 3 days with both control room emergency 3.7.3 LCO 3.11.A.3 ventilation subsystems inoperable. After this time period the plant must be in a cold shutdown within 24 Note, 3.7.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and any handling of irradiated fuel, core alterations, and operations with a potential for draining ACTIONS B, the reactor vessel shall be suspended as soon as practicable. The ITS does not allow this condition to C, E, and F occur; an shutdown will be required if both CREVAS subsystems are inoperable due to actual inoperability of the CREVAS subsystems. However, the ITS allows 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to restore an inoperable control room boundary in MODES 1, 2, and 3. Failing to restore the boundary following these provisions, the plant is required to be in cold shutdown within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. In addition, the ITS provides an intermittent allowance to administratively open the control room boundary (which impacts both division of CREVAS).

M5 The CTS requires the main control room emergency ventilation air supply system capacity to be tested SR 3.7.3.3 4.11.A.5 every 18 months to assure that it is within 10% of the design value of 1000 cfm. The ITS will require a verification that each CREVAS subsystem can maintain a positive pressure of >_ 0.125 inches of water gauge relative to atmosphere and turbine building during the isolate mode of operation at a flow rate of

__ 900 scfm and _< 1100 scfm every 18 months on a STAGGERED TEST BASIS (added per DOC L1).

M6 The CTS requires the suspension of any handling of irradiated fuel, whenever both control room 3.7.3 ACTION 3.11.A.3, emergency ventilation systems are inoperable. If this action cannot be completed LCO 3.0.C must be E Note 3.0.C entered and a plant shutdown is required. The ITS includes a Note that provides an exception to ITS LCO 3.0.3 if the Required Actions can not be met. This clarification was necessary because defaulting to LCO 3.0.3 would require the reactor to be shutdown but would not require the suspension of the activities that have the potential for releasing radioactivity that might require isolation of the control room and operation of theCREVASSystem in the isolate mode.

3.7.4, CONTROL ROOM AC SYSTEM PAGE 3 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 A new Specification is added that delineates specific requirements for operability of the Control Room 3.7.4 N/A Air Conditioning System. This system is necessary to assure the habitability of the control room in a post design basis accident environment. The new Specification requires two subsystems to be OPERABLE in MODES 1, 2 and 3; during the movement of irradiated fuel assemblies in the secondary containment; during CORE ALTERATIONS, and during operations with a potential for draining the reactor vessel (OPDRV). Appropriate ACTIONS and a Surveillance Requirement have been added.

3.7.5, MAIN CONDENSER STEAM JET AIR EJECTOR OFFGAS M1 The RETS (Surveillance Requirement) requires the gross activity to be determined within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> SR 3.7.5.1 RETS 3.5.a.2 following an increase of greater than 50% (factoring out increases due to changes in thermal power (SR section) level) in the nominal steady state fission gas release. In the ITS, this frequency has been changed to include an increase equivalent to 50%. This is an inconsequential change that is considered more restrictive since technically it increases the range of releases to be considered.

M2 The RETS (Surveillance Requirement) allows the gross radioactivity rate of noble gases from the SJAE N/A RETS 3.5.a to be determined by sampling either at the discharge of the SJAE (prior to dilution and/or discharge) or (SR section) at the recombiner discharge (prior to delay of the offgas to reduce the total radioactivity). The second sample point allowance is not being included in the ITS. The sample must be taken at the discharge of the SJAE, consistent with the LCO statement.

3.7.6, MAIN TURBINE BYPASS SYSTEM M1 A new Specification requiring the Main Turbine Bypass System to be Operable has been added. The 3.7.6 N/A Specification requires the Main Turbine Bypass System to be Operable or LHGR and MCPR penalties to be applied. This Specification will help ensure the safety analyses assumptions of certain events are maintained by limiting the resulting LHGR and MCPR if the event were to occur during power operation.

Appropriate ACTIONS and Surveillance Requirements have also been added.

PAGE 4 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.7 - PLANT SYSTEMS

SUMMARY

3.7.7, SPENT FUEL STORAGE POOL WATER LEVEL M1 The CTS requires the spent fuel storage pool level be maintained at a minimum level of 33 ft LCO 3.7.7, 3.10.C (equivalent to 17 feet above the top of irradiated fuel assemblies seated in the spent fuel storage racks).

SR 3.7.7.1 The ITS requires this level to be maintained at 21 ft 7 inches over the top of irradiated fuel assemblies seated in the spent fuel storage pool. This will ensure that the consequences of a refueling accident over the spent fuel pool storage pool will remain within the bounds of the refueling accident described in UFSAR,_Section_14.6.1.4.

M2 The CTS does not provide any specific actions when the LCO is not met. Therefore when the LCO is 3.7.7 ACTION 3.1.0.C not met, CTS 3.0.C must be entered and the reactor placed in COLD SHUTDOWN within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

A This shutdown requirement has been deleted as discussed in DOC L3 for this Specification and a more appropriate ACTION is provided. The ITS will immediately require the suspension of movement of irradiated fuel in the spent fuel pool; thus, an accident cannot occur.

CTS 3/4.8, MISCELLANEOUS RADIOACTIVE MATERIALS SOURCES NONE NONE NONE NONE CTS 3/4.11.C, BATTERY ROOM VENTILATION NONE NONE NONE NONE PAGE 5 I

I JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.8.1, AC SOURCES - OPERATING M1 The CTS requires the LCO to be met prior to making the reactor critical, which effectively implies MODES 3.8.1 3.9.A 1 and 2. The ITS Applicability requires AC sources be OPERABLE in MODES 1, 2, and 3.

Applicability M2 Six new Surveillance Requirements have been added. The ITS requires a) a verification that each day SR 3.8.1.4, SR N/A tank contains > 327 gallons of fuel oil every 31 days; b) a check for and removal of accumulated water 3.8.1.5, SR from each day tank every 31 days; c) a verification of automatic and manual transfer of plant power 3.8.1.7, SR supply from the normal station service transformer to each offsite circuit every 24 months (note: only 3.8.1.8, SR required if the offsite circuit is not energizing its respective 4.16 kV emergency bus); d) a verification that 3.8.1.11, SR each EDG subsystem rejects a load greater than or equal to a load equivalent to one core spray pump 3.8.1.13 every 24 months; e) a verification that each EDG pair operating within the power factor limit (except when grid conditions will not permit, and then as close to the limit as practicable) operates for_> 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> loaded from 105% to 110% of the continuous rating, and for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> loaded from 90% to 100% of the continuous rating every 24 months; and f) a verification that the interval between each sequenced load block is greater than or equal to the minimum design interval every 24 months.

M3 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if the 3.8.1 Required N/A corresponding AC sources are not restored within the associated completion times. In the ITS, an Action F.1 intermediate condition, MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

M4 The ITS includes additional actions to limit the time the LCO is not met. When an AC Source is 3.8.1 Required N/A inoperable, the ITS includes a second Completion Time of 21 days from the discovery of failure to meet Actions A.3 and the LCO, which imposes a limit on the maximum time allowed for any combination of required AC power B.4 sources to be inoperable during any single contiguous occurrence of failing to meet the LCO.

M5 Not used.

N/A N/A M6 Not used.

N/A N/A M7 The CTS requires a demonstration of the ability of each EDG subsystem to start, accelerate, and force SR 3.8.1.2 4.9.8.1 parallel; however, no acceptance criteria are provided. The ITS requires the EDG subsystem also meet Ispecific values for time, voltage and frequency.

M8 The CTS requirement to load each EDG monthly does not restrict this test from being performed on more SR 3.8.1.3 Note 4.9.B.1 that one EDG subsystem at a time. The ITS includes a restriction on performing this test on more than 3

one EDG at a time.

JAFNPP PAGE 1

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M9 Two new 24 month Surveillances have been added. The ITS will require a) a verification that, on an SR 3.8.1.9, SR N/A actual or simulated loss of offsite power signal, the emergency bus is de-energized, load shedding 3.8.1.10 occurs, and each EDG subsystem will auto-start from standby condition and properly energize and maintain energized the respective emergency buses/loads; and b) a verification that, on an actual or simulated ECCS initiation signal, each EDG subsystem will auto-start from standby condition and properly operate unloaded, and the emergency buses stay energized from offsite power and the loads properly auto-start.

M10 Not used.

N/A N/A Ml1l The CTS requires a demonstration of the ability, under required conditions (loss of power signal, ECCS SR 3.8.1.9, SR 4.9.B.4 initiation signal, loss of power signal in conjunction with ECCS signal), of each EDG subsystem to start, 3.8.1.10, SR accelerate, force parallel and accept emergency loads in the prescribed sequence; however, no specific 3.8.1.12 acceptance criteria is specified. The ITS requires the EDG subsystem meet specific values for time, voltage, frequency and loading duration.

M12 A new 7 day Surveillance has been added to verify the offsite circuit breaker alignment and power SR 3.8.1.1 N/A availability.

M13 The CTS does not specify which EDG fuel oil transfer pumps must be OPERABLE. The ITS will require LCO 3.8.1, SR 3.9.C.2.b, each diesel generator to have at least one transfer pump capable to transfer oil from its corresponding 3.8.1.6 3.9.C.2.c storage tank to day tank automatically. If this requirement is not met the associated diesel generator 4.9.C.2 must be declared inoperable. In addition, the CTS allows 30 days to restore an inoperable transfer pump.

The ITS will require the EDG to be declared inoperable, thus 14 days will be allowed to restore an inoperable pump. In addition CTS 3.9.C.2.c has been deleted since the association between the fuel oil transfer system will now correspond to the associated EDG and not the EDG subsystem.

3.8.2, AC SOURCES - SHUTDOWN M1 The CTS does not specify what the one required offsite power source must be powering. The ITS LCO 3.8.2.a and 3.9.D specifies that offsite AC power sources must be available to supply power to all equipment required to be b

OPERABLE by ITS LCO 3.8.8. Thus the ITS LCO could require two offsite circuits if both class 1 E AC electrical power distribution divisions are required.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS does not specify what the one required EDG subsystem must be powering. The ITS specifies LCO 3.8.2.c 3.9.D that the EDG subsystem must be capable of supplying power to one division of the equipment required to be OPERABLE by ITS LCO 3.8.8.

M3 The ITS adds a new Applicability of during movement of irradiated fuel assemblies in the secondary 3.8.2 N/A containment. This condition could include while being in MODE 1, 2, or 3, or when there is no fuel in the Applicability vessel.

M4 Due to the addition of the new Applicability described in DOC M3 above, the ITS include a Note that 3.8.2 ACTIONS N/A states LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODES 4 or 5, LCO Note 3.0.3 is not applicable and would not specify any action. If moving irradiated fuel assemblies while in MODES 1, 2, or 3, the fuel movement is independent of reactor operations and the inability to suspend movement in accordance with the ITS 3.8.2 Required Actions would not be sufficient reason to require a reactor shutdown.

M5 The CTS does not include any Surveillances for verifying the Operability of AC Sources during cold SR 3.8.2.1 N/A shutdown or refueling. The ITS includes appropriate Surveillances to ensure the Operability of the required AC sources.

3.8.3, DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR M1 The CTS allows 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> to restore the fuel oil level to the 7 day limit, when a fuel oil tank is less than the 3.8.3 Action A, 3.9.C, 3.9.C.3 7 day limit. The ITS will allow the same 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />, but will only allow the time if the fuel oil level in the tank 3.8.3 ACTION F, is greater than the six day limit. If the six day limit is not met or the 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is exceeded, then the ITS SR 3.8.3.1 will require the associated EDG to be declared inoperable. In addition, the ITS specifies the fuel oil limit on a per EDG basis versus the CTS method of on a per EDG subsystem basis.

M2 New requirements are added to maintain a proper amount of lube oil inventory for EDG operation.

LCO 3.8.3, 3.8.3 N/A Appropriate LCO requirements, ACTIONS, and a Surveillance Requirement have been added.

ACTIONS B and F, SR 3.8.3.2 M3 In the ITS, the new and stored fuel oil properties are in a separate LCO, thus a new LCO statement is LCO 3.8.3, 3.8.3 N/A provided. In addition, a new Surveillance and attendant ACTIONS are provided to ensure the new and ACTIONS C, D, stored fuel oil properties are tested and maintained in accordance with the Diesel Fuel Oil Testing and F, SR Pronram.

3.8.3.3 PAGE 3 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M4 The CTS includes the starting air as an attribute of the EDGs. In the ITS, the starting air requirements are LCO 3.8.3, 3.8.3 4.9.B.2 in a separate LCO, thus a new LCO statement is provided. In addition, the proper ACTIONS for when ACTIONS E and starting air is inoperable has been added. Also, the CTS does not have a specific requirement for the F, SR 3.8.3.4 starting air pressure. The ITS includes the proper starting air pressure needed to support EDG Operability.

3.8.4, DC SOURCES - OPERATING M1 The CTS requires the LCO to be met prior to making the reactor critical, which effectively implies MODES 3.8.4 3.9.E.1, 3.9.F.1 1 and 2. The ITS Applicability requires AC sources be OPERABLE in MODES 1, 2, and 3.

Applicability M2 The CTS allows 7 days total per calendar month to restore an inoperable 125 VDC battery. The ITS only 3.8.4 ACTION A 3.9.E.2 allows 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to restore an inoperable DC electrical power subsystem.

M3 The CTS requires a measurement of overall battery voltage; however, no acceptance criteria is provided.

SR 3.8.4.1 4.9.E.1, 4.9.F.1 The ITS includes float voltage limitations for the 125 VDC and 419 VDC batteries.

M4 The CTS requires a 125 VDC battery charger performance test; however, no acceptance criteria is SR 3.8.4.2 4.9.E.6 provided. The ITS includes the required current, voltage, and time duration of the 125 VDC battery charger performance test.

M5 Not used.

N/A N/A M6 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if the inoperable 3.8.4 Required N/A DC source is not restored within the associated completion time. In the ITS, an intermediate condition, Action B.1 MODE 3, must be met within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

3.8.5, DC SOURCES - SHUTDOWN M1 A new Specification is being added requiring one 125 VDC electric power subsystem to be operable and capable of supplying one division of the onsite Class 1E DC Electrical Power Distribution System required by proposed LCO 3.8.8, "Distribution Systems -

Shutdown". Appropriate ACTIONS and a Surveillance Requirement have also been added.

PAGE 4 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.8.6, BATTERY CELL PARAMETERS M1 The CTS requires that the reactor shall not be made critical unless both station batteries (including the 3.8.6 3.9.E.1, 3.9.F.1 battery cell parameters) and both LPCI MOV Independent Power Supplies (including the battery cell Applicability parameters) are in service, which effectively implies MODES 1 and 2. The ITS requires the battery cell parameters to be within limits when the associated DC electrical power subsystems are required to be Operable. Thus, the 125 VDC battery cell parameters are now required in MODES 1, 2, 3, 4, and 5, and during movement of irradiated fuel assemblies in the secondary containment, and the 419 VDC battery cell parameters are now required in MODES 1, 2, and 3.

M2 The CTS does not address requirements for a battery cell parameter not within limits. The ITS provides 3.8.6 ACTION A N/A an ACTION for when one or more battery cell parameters are not within Category A or B limits.

M3 The CTS does not address requirements for a battery cell parameter not within limits. The ITS provides 3.8.6 ACTION B N/A an ACTION for when the battery cell parameters of a battery cell not meeting Category A or B limits are not restored, one or more batteries with average electrolyte temperature of the representative cells not within limits, or one or more batteries with one or more battery cell parameters are not within Category C values.

M4 The ITS includes a new requirement to verify the electrolyte level of connected battery cells (pilot cells SR 3.8.6.1, SR N/A and all cells) meets the Category A and B limits. The pilot cells are checked weekly and all cells are 3.8.6.2 checked quarterly.

M5 The ITS establishes electrolyte level, float voltage, and specific gravity limits for each pilot cell and each Table 3.8.6-1 N/A connected cell. Currently, no limits are specified in the CTS.

M6 The CTS requires cell temperature to be measured; however, no specific acceptance criteria is provided.

SR 3.8.6.3 4.9.E.2.c, The ITS includes a specific limit for battery cell temperature.

4.9.F.2.c 3.8.7, DISTRIBUTION SYSTEMS - OPERATING Ml The CTS requires the LCO to be met prior to making the reactor critical, which effectively implies MODES 3.8.7 3.9.A, 3.9.E 1 and 2. The ITS Applicability requires AC sources be OPERABLE in MODES 1,2, and 3.

Applicability M2 A new 7 day Surveillance Requirement has been added to verify correct breaker alignment and voltage to SR 3.8.7.1 N/A required AC and 125 VDC electrical power distribution subsystems.

PAGE 5 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.8 - ELECTRICAL POWER SYSTEMS DOC #

SUMMARY

ITS SECTION CTS SECTION M3 The CTS requires the reactor to be placed in cold shutdown (MODE 4) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if an AC or DC 3.8.7 Required N/A distribution subsystem is inoperable. In the ITS, an intermediate condition, MODE 3, must be met within Action C.1 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

3.8.8, DISTRIBUTION SYSTEMS - SHUTDOWN M1 A new Specification is being added requiring the necessary portions of the AC and 125 VDC electrical 3.8.8 N/A power distribution subsystems to be Operable to support equipment required to be Operable. An appropriate ACTION and a Surveillance Requirement have also been added.

PAGE 6 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.9 - REFUELING OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.9.1, REFUELING EQUIPMENT INTERLOCKS M1 The CTS requires testing of refueling interlocks, but does not specify the actual interlocks by name. In SR 3.9.1.1 4.10O.A.1 the ITS, each actual refueling equipment interlock, by name, is listed in the Surveillance Requirement.

3.9.2, REFUEL POSITION ONE-ROD-OUT INTERLOCK M1 The CTS requires that the reactor mode switch be locked in the Refuel position during core alterations, SR 3.9.2.1 N/A but no Surveillance Requirement is provided to periodically verify this requirement. In the ITS. a new Surveillance Requirement will require verification every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> that the mode switch remains locked in the "Refuel" position.

M2 The CTS does not provide specific actions to take when the one-rod-out interlock is inoperable. In the 3.9.2 ACTION A N/A ITS, a new ACTION requires the immediate suspension of control rod withdrawal and action to be immediately initiated to fully insert all insertable control rods in core cells containing one or more fuel assemblies.

3.9.3, CONTROL ROD POSITION M1 The CTS requires that all control rods be inserted prior to loading fuel, but no Surveillance Requirement is SR 3.9.3.1 N/A provided to periodically verify this requirement. In the ITS, a new Surveillance Requirement will require verification that all control rods are fully inserted when loading fuel assemblies in the core every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

3.9.4, CONTROL ROD POSITION INDICATION M1 A new Specification concerning Control Rod Position Indication is added. The new Specification will 3.9.4 N/A require that the control rod "full-in" position indication for each control rod be Operable when in MODE 5, which helps to ensure that safety analysis assumptions of UFSAR, Section 14.5.4.3, "Control Rod Removal Error During Refueling" and Section 14.5.4.4, "Fuel Assembly Insertion Error During Refueling" are satisfied. An appropriate ACTION and Surveillance Requirement are also added.

3.9.5, CONTROL ROD OPERABILITY - REFUELING PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.9 - REFUELING OPERATIONS

SUMMARY

ITS SECTION CTS SECTION A new Specification concerning Control Rod Operability during refueling is added. The new Specification 3.9.5 N/A will require that each withdrawn control rod must be Operable when in MODE 5, which helps ensure control rod scram capability exists and constitutes a more restrictive change. An appropriate ACTION and Surveillance Requirements are also added.

I 8

3.

R ::.RACTOR PRFSSUIRE VESSEL WATER LEVEL M1 A new Specification concerning reactor vessel water level is added. The new Specification requires that 3.9.6 N/A Reactor Pressure Vessel (RPV) water level be Ž 22 ft 2 inches above the top of the RPV flange during the movement of fuel assemblies and control rods within the RPV flange, since this helps ensure that the doses at the site boundary will be within limits and constitutes a more restrictive change. An appropriate ACTION and Surveillance Requirement are also added._I 3.9.7, RESIDUAL HEAT REMOVAL - HIGH WATER LEVEL M1 A new Specification for the RHR shutdown cooling (SDC) subsystem in MODE 5 is added. The new 3.9.7 N/A Specification requires that one RHR SDC subsystem be Operable in MODE 5 with water level 2 22 ft 2 inches above the top of the RPV flange. Appropriate ACTIONS and a Surveillance Requirement are also added.

3.9.8, RESIDUAL HEAT REMOVAL - LOW WATER LEVEL M1 A new Specification for the RHR shutdown cooling (SDC) subsystems in MODE 5 is added. The new 3.9.8 N/A Specification requires that two RHR shutdown cooling subsystems be Operable in MODE 5 with water level < 22 ft 2 inches above the top of the RPV flange. Appropriate ACTIONS and a Surveillance Requirement are also added.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.10 - SPECIAL OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION 3.10.1, INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION NONE NONE NONE NONE 3.10.2, REACTOR MODE SWITCH INTERLOCK TESTING NONE NONE NONE NONE 3.10.3, SINGLE CONTROL ROD WITHDRAWAL - HOT SHUTDOWN NONE NONE NONE NONE 3.10.4, SINGLE CONTROL ROD WITHDRAWAL - COLD SHUTDOWN NONE NONE NONE NONE 3.10.5, SINGLE CONTROL ROD DRIVE REMOVAL - REFUELING M1 The CTS allows two control rods to be withdrawn from the reactor for maintenance. The ITS allows only LCO 3.10.5.a, 3.10.D.1 one control rod to be withdrawn and subsequently removed from a core cell containing one or more fuel SR 3.10.5.1 assemblies. The number of control rods allowed to be withdrawn (with fuel assemblies not removed from around the control rod) has been reduced to one. The removal of more than one control rod will be controlled in accordance with ITS 3.10.6. In addition, since only one control rod may be withdrawn, the CTS separation criteria requirement has been deleted and the ITS includes a new requirement to have all other control rods fully inserted. In addition, a Surveillance Requirement has been added to verify all control rods, other than the control rod withdrawn for the removal of the associated CRD, are fully inserted every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

M2 The CTS requires the disarming of the control rods immediately facing and diagonally adjacent to the LCO 3.10.5.b, 3.10.D.1.b control rods to be withdrawn. The ITS increase this requirement to include all control rods in a 5 x 5 array SR 3.10.5.2 centered on the withdrawn control rod. In addition, a Surveillance Requirement has been added to verify the soecified control rods are disarmed every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />._I

_1__1 PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.10 - SPECIAL OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION M3 Two new Surveillances have been added. ITS SR 3.10.5.3 will require the verification that a control rod SR 3.10.5.3, SR N/A block is inserted and ITS SR 3.10.5.5 will require that no other CORE ALTERATIONS are in progress 3.10.5.5 every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />._I M4 The CTS does not provide any actions of the LCO requirements are not met. The ITS includes an 3.10.5 ACTION N/A ACTION that will require the immediate suspension of the CRD mechanism removal and the immediate A

initiation of action to fully insert all control rods or to initiate immediate action to satisfy the requirements of this LCO.

3.10.6, MULTIPLE CONTROL ROD WITHDRAWAL - REFUELING M1 The CTS requires the verification that the control cell contains no fuel before the corresponding control SR 3.10.6.1 4.10.A.2 rod is withdrawn; however, no periodic frequency is required. The ITS requires the verification that the four fuel assemblies are removed from the core cells associated with each control rod or CRD removed at a surveillance frequency of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

M2 Two new Surveillance Requirements have been added. SR 3.10.6.2 requires verification every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> SR 3.10.6.2, SR N/A that all other control rods in core cells containing one or more fuel assemblies to be fully inserted and SR 3.10.6.3 3.10.6.3 requires verification every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> that fuel assemblies being loaded are in compliance with an approved spiral reload sequence. Currently, these Surveillances are not required in the CTS.

3.10.7, CONTROL ROD TESTING - OPERATING NONE NONE NONE NONE 3.10.8, SHUTDOWN MARGIN TEST - REFUELING M1 The CTS does not require safety/relief valves (S/RVs) to be Operable during reactor operator training with N/A 3.6.E.3, 3.5.B.5 the reactor coolant temperature < 212°F and with the reactor vessel vented (MODE 4) or with the reactor vessel head removed (MODE 5). In addition, the CTS does not require the Containment Cooling Mode of the RHR System to be Operable with reactor coolant temperature < 212 0F. These exceptions to the I current operabilitV requirements are not included in the ITS.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX SECTION 3.10 - SPECIAL OPERATIONS DOC #

SUMMARY

ITS SECTION CTS SECTION M2 The CTS does not require safety/relief valves to be Operable during low power physics testing with the N/A 3.6.E.3 reactor coolant temperature < 212°F and with the reactor vessel vented. The current Applicability is considered to be MODE 4 in the ITS however there is no requirement to have the reactor vessel vented (see Discussion of Changes for ITS Chapter 1.0). This exception to allow this testing in MODE 4 is not included in the ITS.

M3 The CTS does not require safety/relief valves to be Operable during low power physics tests. In addition, N/A 3.6.E.3, 3.5.B.5 the CTS does not require components of the Containment Cooling Mode of the RHR System. Currently, there are no specific requirements to perform a low power physics tests in the CTS other than shutdown margin demonstrations in CTS 4.3.A.1. Low power physics tests were completed during the startup test program. ITS 3.10.8 allows the performance of a SDM test during MODE 5 with the reactor mode switch in the startup/hot standby position. Since SDM tests are considered the only low power physics tests permitted by the ITS, this change is considered more restrictive since a License Amendment must be processed prior to the performance of any specified low power physics test.

M4 The CTS requires all operable control rods to be inserted within four hours when the requirements of the 3.10.8 ACTION Table 3.1-1 APRM Neutron Flux-Startup or APRM Inoperative function are not met. The ITS requires the reactor B

Note 3.A mode switch to be placed in the shutdown or refuel position immediately.

JAFNPP PAGE 3

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 4.0 - DESIGN FEATURES

SUMMARY

ITS SECTION CTS SECTION The CTS defines the exclusion area boundary to be approximately a 3,200 ft. radius corresponding to the closest distance from the reactor building, with the exception of the lake shoreline, to the exclusion area boundary consistent with 10 CFR 100.3. The ITS specifies that the Site and the Exclusion Area Boundaries are as shown in Figure 4.1-1, which expands the dimensions of the Exclusion Area. The area shown in ITS Figure 4.1-1 is consistent with: CTS RETS Definition 1.0.L, of the Site Boundary, which refers to CTS RETS Figure 5.1-1 for a map of the Site Boundary; UFSAR Section 2.1.1 which states that exclusion distances for the NMP-JAF site are approximately 3000 ft to the east, over a mile to the west, and about one and one-half miles to the southern site boundary; and the James A. FitzPatrick Emergency Plan which explicitly identifies the Exclusion Area as the Entergy and NMPC property surrounding the Protected Area in which the licensee has the authority to determine all activities including exclusion or removal of personnel and property from the area, all of which correspond to the r, nmhined site hboundrv fnr the.Jaimes A Fit7Patrick-Nine Mile Point site.

4.1.1 5.1.2, RETS 1.0.L, RETS Figure 5.1-1 M2 The CTS does not currently describe the Low Population Zone. The ITS includes the Specification for 4.1.2 N/A the Low Population Zone (LPZ), which is identified as a 4 mile radius around the Nine Mile Point Nuclear Station Unit 1 stack.

M3 The CTS does not identify the elevation, for the minimum water level, to which the spent fuel storage 4.3.2 N/A pool is designed and shall be maintained to prevent inadvertent draining. The ITS includes the Specification, which identifies the minimum design elevation, 344 feet 6 inches, to which the spent fuel storage pool can be drained with the gates not installed (which is the normal condition of the spent fuel storage pool during refueling operations). At the minimum design elevation, the fuel will remain covered as required by Regulatory Guide 1.13, Revision 1.

JAFNPP lVI I PAGE 1

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION 5.1, RESPONSIBILITY M1 Not used.

N/A N/A M2 The ITS adds a requirement that the plant manager or his designee approve each proposed test, 5.1.1 N/A experiment, and modification to systems or equipment that affect nuclear safety prior to implementation.

M3 ITS 5.1.2 has been added to require that the shift supervisor be responsible for the control room 5.1.2 N/A command function, and that in the absence of the shift supervisor from the control room, an individual with an active SRO license be designated to assume the control room command function when the plant is in MODE 1, 2, or 3. An individual with an active SRO license or RO license can be designated to assume the control room command function when the plant is in MODE 4 or 5.

5.2, ORGANIZATION M1 The CTS allows up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to restore the shift crew to the minimum complement in the event of illness 5.2.2.b, 5.2.2.c 6.2.2.4 or unexpected absence. The ITS allows the same amount of time (2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />), however immediate action must be taken to restore the shift crew composition to within the minimum requirements.

5.3, PLANT STAFF QUALIFICATIONS NONE NONE I

NONE NONE 5.4, PROCEDURES M1 Two classifications of procedures are added to the ITS which, although currently exist, are not required by 5.4.1.b, 5.4.1.e N/A the current Technical Specifications. The ITS requires establishing, implementing and maintaining a) emergency operating procedures required to implement the requirements of NUREG-0737 and NUREG 0737, Supplement 1, as stated in Generic Letter 82-33, and b) all programs specified in ITS 5.5.

5.5, PROGRAMS AND MANUALS PAGE 1 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 5.0 -ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION M1 The ITS adds a requirement that the ODCM shall become effective only after approval of the plant 5.5.1.c.2 N/A manager.

M2 New testing requirements for the filter trains (SGT and CREVAS Systems) are being added. The ITS 5.5.8, 5.5.8.a, 4.7.B.1.a.2, adds the following new requirements: a) (SGT only) filter train heater testing be in accordance with ANSI 5.5.8.b, 5.5.8.d, 4.7.B.1.b, N510-1975, which includes a new requirement that each phase current be within 5% of one another; b) 5.5.8.e 4.7.B.1.b.1, (SGT only) the new condition following painting, fire, or chemical release that could adversely affect the 4.7.B.1.b.2, ability of the filter system to perform the intended function in any ventilation zone communicating with the 4.11.A.1.a, system is being added to the filter efficiency testing; c) (SGT only) to demonstrate particulate filter 4.11.A.1.b, efficiency in accordance with Sections C.5.a and C.5.c of Regulatory Guide 1.52, Rev 2, and at a flow 4.11.A.1.c rate of 5400 to 6600 scfm; d) (SGT only) to demonstrate charcoal filter removal efficiency in accordance with Sections C.5.a and C.5.d of Regulatory Guide 1.52, Rev 2, and at a flow rate of 5400 to 6600 scfm; e) (CREVAS only) the requirement for the pressure drop across the filter system to be less than 5.8 inches of water at a system flowrate of 900 to 1100 scfm; f) (CREVAS only) the new conditions; after each complete or partial replacement of the HEPA filter, after any structural maintenance on the HEPA filter housing that could affect the filter system efficiency, and following painting, fire, or chemical release that could adversely affect the ability of the filter system to perform the intended function in any ventilation zone communicating with the system are being added to the HEPA filter efficiency testing; g) (CREVAS only) to demonstrate the di-octylphtalate test for particulate filter efficiency for particulate greater than 0.3 micron in accordance with Sections C.5.a and C.5.c of Regulatory Guide 1.52, Rev 2, and at a flow rate of 900 to 1100 scfm; h) (CREVAS only) the new conditions; after each complete or partial replacement of the charcoal adsorber filter; after removal of a charcoal adsorber sample; after any structural maintenance on the charcoal adsorber housing that could affect the filter system efficiency, and following painting, fire, or chemical release that could adversely affect the ability of the filter system to perform the intended function in any ventilation zone communicating with the system are being added to the charcoal adsorber filter efficiency testing; and i) (CREVAS only) to demonstrate charcoal filter halogen removal efficiency in accordance with Sections C.5.a and C.5.d of Regulatory Guide 1.52, Rev 2, and at a flow rate of 900 to 1100 scfm.

M3 ITS 5.5.10, "Diesel Fuel Oil Testing Program," which establishes testing and sampling requirements, and 5.5.10 N/A acceptance criteria, in accordance with ASTM Standards, for both stored fuel oil and new fuel oil, is being added. ITS 5.5.10 establishes additional requirements relative to new fuel oil testing and to determine that particulate concentration for diesel fuel oil is

  • 10 mg/I every 31 days.

M4 ITS 5.5.11, "Technical Specifications (TS) Bases Control Program," is added. This Program provides a 5.5.11 N/A r__

ontrolled mechanism for orocessinQ changes to the Bases of the Technical Specifications.

PAGE 2 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION M5 ITS 5.5.12, "Safety Function Determination Program (SFDP)," is added. This program ensures that any 5.5.12 N/A loss of safety function is detected and that appropriate actions are taken.

M6 New requirements concerning the ODCM are added. The ITS specifies that the ODCM will contain 5.5.1 N/A radioactive effluent controls and radiological environmental monitoring activities and descriptions of information that should be included in the Annual Radiological Environmental Operating, and Radioactive Effluent Release reports. In addition expanded requirements of the ODCM identify monitoring activities and report requirements, and establish content and format for documenting licensee-initiated changes.

M7 The ITS, specifies that the systems covered by the Primary Coolant Sources Outside Containment 5.5.2 Facility Program are Core Spray, High Pressure Coolant Injection, Residual Heat Removal, Reactor Core Operating Isolation Cooling, Reactor Water Cleanup, process sampling and Standby Gas Treatment. Currently, the License 2.C.4 actual systems are not specified.

5.6, REPORTING REQUIREMENTS M1 The CTS requires submittal of an Annual Occupational Exposure Tabulation on an annual basis. The ITS 5.6.1 6.9.A.2.a requires that an Occupational Radiation Exposure Report be submitted by April 30 of each year. This change adopts a specific date for submittal of a report.

M2 The CTS requires that the Monthly Operating Report should be submitted by the 15th of each month.

5.6.4 6.9.A.3 The ITS changes the word "should" to "shall."

5.7, HIGH RADIATION AREA NONE NONE NONE NONE CTS 6.0, ADMINISTRATIVE CONTROLS NONE NONE NONE NONE RETS 2.1, LIQUID EFFLUENT MONITORS PAGE 3 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION NONE NONE NONE NONE RETS 2.2, CONCENTRATION OF LIQUID EFFLUENTS NONE NONE NONE NONE RETS 2.3, DOSE FROM LIQUID EFFLUENTS NONE NONE NONE NONE RETS 2.4, LIQUID RADIOACTIVE WASTE TREATMENT SYSTEM OPERATIONS NONE NONE NONE NONE RETS 3.1, GASEOUS EFFLUENT MONITORS NONE NONE NONE NONE RETS 3.2, GASEOUS DOSE RATES NONE NONE NONE NONE RETS 3.3, AIR DOSE, NOBLE GASES NONE NONE NONE NONE RETS 3.4, DOSE DUE TO IODINE-131, IODINE-133, TRITIUM, AND RADIONUCLIDES IN PARTICULATE FORM PAGE 4 JAFNPP

TABLE M - MORE RESTRICTIVE CHANGES MATRIX CHAPTER 5.0 - ADMINISTRATIVE CONTROLS DOC #

SUMMARY

ITS SECTION CTS SECTION NONE NONE NONE NONE RETS 3.6, OFFGAS TREATMENT SYSTEM NONE NONE NONE NONE RETS 4.0, SOLID RADIOACTIVE WASTE - PROCESS CONTROL PROGRAM NONE NONE NONE NONE RETS 5.0, TOTAL DOSE - TOTAL DOSE FROM URANIUM FUEL CYCLES NONE NONE NONE NONE RETS 6.1, MONITORING PROGRAM NONE NONE NONE NONE RETS 6.2, LAND USE CENSUS PROGRAM NONE NONE NONE NONE RETS 6.3, INTERLABORATORY COMPARISON PROGRAM NONE NONE NONE NONE PAGE 5 JAFNPP