Nuclear Criticality SafetyML031180568 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Issue date: |
03/06/1989 |
---|
From: |
Cunningham R NRC/NMSS/IMNS |
---|
To: |
|
---|
References |
---|
IN-89-024, NUDOCS 8902280162 |
Download: ML031180568 (7) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] </code>. |
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS
WASHINGTON, D.C. 20555 March 6, 1989 NRC INFORMATION NOTICE NO. 89-24: NUCLEAR CRITICALITY SAFETY
Addressees
All fuel cycle licensees and other licensees possessing',ore than critical mass
quantities of special nuclear material.
Purpose
This information notice is being provided to alert addressees to potential
problems resulting from inadequate administration and application of the
double contingency principle in establishing nuclear criticality safety limits
and controls. It is expected that licensees will review the information for
applicability to their facilities and consider actions, as appropriate, to
avoid similar problems. However, suggestions contained in this information
notice do not constitute U.S. Nuclear Regulatory Commission (NRC) requirements;
therefore, no specific action or written response is required.
Description of Circumstances
The double contingency principle, as used in ANSI/ANS-8.1-1983*, states that
"Process designs should, in general, incorporate sufficient factors of safety
to require at least two unlikely, independent, and concurrent changes in process
conditions before a criticality accident is possible.' Proper application of
the double contingency principle provides assurance that no single error or
loss of a control will lead to the possibility of a criticality accident.
In March 1988, an NRC licensee was authorized to operate a new pilot plant
operation involving highly enriched uranium solution. Provisions were made
to remove liquid scrap in 2.5 liter bottles from the operations area (Area 1).
Because of increased quantities of scrap solution and lack of temporary storage, an alternate liquid-handling process was established. The alternate method
allowed both dilute and concentrated scrap solution to be stored in 11-liter
bottles in the same area.'-After an analysis of a single sample, the 11-liter
bottles of dilute scrap solution were to be transferred to an adjacent area
(Area 2) and emptied into mass-limited 55-gallon drums.
- American National Standard For Nuclear Criticality Safety in Operations With
Fissionable Materials Outside Reactors, ANSI/ANS-8.1-1983.
IN 89-24 March 6, 1989 During an inspection in July 1988, NRC personnel recognized that an operator
could inadvertently transfer an unsafe quantity of scrap solution into a drum
by either selecting the wrong bottle of solution or as a result of an erroneous
sample analysis. Such an unsafe transfer could have been effected with only
one unlikely, independent, and concurrent change in process conditions (viz.,
selecting the wrong bottle, recording the wrong analysis or using the wrong
sample analysis, etc.) and hence, the double contingency principle was not
satisfactorily implemented. Because this method of handling 11-liter bottles
was somewhat similar to the handling method contributing to the Wood River
Junction accident in 1964, the NRC inspectors expressed concern. The licensee
immediately ceased all scrap handling and subsequently shutdown the entire
process area to review the safety limits and controls.
Further review disclosed that the nuclear criticality safety-analyst who had
analyzed the process before startup was not familiar with the alternate scrap- solution-handling procedure. Administrators within the licensee's safety group
had approved the change because a safe mass limit had been imposed on each drum
in Area 2. The licensee claimed that the alternate method of solution-handling, permitted by procedure, had not been used because the material control and
accounting restrictions made the method inefficient.
NRC personnel also noted that Area 2 contained several open 55-gallon drums.
Area 2 was used to remove solids from Raschig ring filled drums which were
used-in Area 3 (scrap recovery). Raschig ring filled drums and drums of
chemicals were taken from Area 2 into Area 3. Because a 55-gallon drum was
involved in the Oak Ridge Y-12-accident, NRC personnel expressed-concern with
the lack of controls on open drums. The licensee immediately shutdown Areas 2 and 3 so that the nuclear criticality safety limits and controls could be re- examined.
Discussion:
These events highlight the need for continuing vigilance in providing a sound
nuclear safety program. Some of the licensee's actions taken after the inspec- tion are discussed here. Licensees are encouraged to review these actions and
their own vigilance in assuring nuclear criticality safety.
A team led by a safety director from another of the licensee's nuclear facili- ties conducted an immediate audit of the three areas. The team consisted of
safety and production personnel. The audit team confirmed NRC's findings and
identified other safety items.
All nuclear criticality safety analyses were reviewed to ensure proper appli- cation of the double contingency principle. Documentation of analyses has been
revised to provide explicit consideration of the double contingency principle.
The nuclear criticality safety analysis group now reviews all changes to nuclear
criticality limits and controls. The administrative group can no longer approve
seemingly simple changes such as authorizing new mass limits for work stations, based on established safe mass limits.
IN 89-24 March 6, 1989 Production personnel were not involved in establishing nuclear safety limits
and were not familiar with the above-mentioned nuclear criticality accidents.
The safety training program has been revised to include selected accident
histories.
All involved personnel, including production operators, have reviewed all
procedures. Before startup of Areas 1, 2, and 3, procedures were revised to
include nuclear safety limits and controls. Procedures in other plant areas
will be revised to include safety limits.
Liquid scrap from Area 1 is now collected in favorable geometry containers.
After analysis, the solution is transferred to a favorable geometry quaran- tine tank for a second analysis. Then the solution is transferred to uniquely
identified favorable geometry containers, for transfer to the drums in Area 2.
Most 55-gallon drums in Area 2 have been eliminated by engineering redesign.
Barriers and other controls are in place to prevent unauthorized transfer of
drums into Area 3. Engineering studies are underway to eliminate or reduce
the use of all unfavorable geometry containers in Area 3.
No specific action or written response is required by this information notice.
If you have questions about this matter, please contact the technical contacts
listed below or the Regional Administrator of the appropriate regional office.
Richard E. Cunningham, Director
Division of Industrial and
Medical Nuclear Safety
Office of Nuclear Material Safety
and Safeguards
Technical Contacts: Gerald Troup, Region II
(404) 331-5566 George Bidinger, NMSS
(301) 492-0683 Attachment: List of Recently Issued NRC Information Notices
U-i
/_'ichment
IN 89-24 March 6, 1989 Paze I of I
LIST OFRECENTLY ISSUED
NRCINFORHATION NOTICES
Infornmtl-. I---*t ".
Notice no. SubJect Issuance Issued to
89-23 Environmental Qualification 3/3/89 All holders of OLs
of Litton-Yeam CIR Series or CPs for nuclear
Electrical Connectors power reactors.
89-22 Questionable Certification 3/3/89 All holders of OLs
of Fasteners or CPs for nuclear
power reactors.
89-21 Changes In Performance 2/27/89 All holders of OLs
Characteristics of Molded. or CPs for nuclear
Case Circuit Breakers power reactors.
88-73, Direction-Dependent Leak 2/27/89 All holders of OLs
Supplement I Characteristics of Contain- or CPs for nuclear
ment Purge Valves power reactors.
89-20 Weld Failures in a Pump 2/24/89 All holders of OLs
of Byron-Jackson Design or CPs for nuclear
power reactors.
89-19 Health Physics Network 2/23/89 All holders of OLs
or CPSfor nuclear
power reactors. and
the following fuel
facilities: Nuclear
Fuel Services of Erwin, General Atomic, UNC
Montville. BW LRC
Lynchburg, and BIM
Lynchburg.
89-18 Criminal Prosecution of 2/22/89 All holders of OLs
WIrongdoing Couumtted by or CPs for nuclear
Suppliers of Nlulear power reactors.
Products or Services
89-17 Contamination and Degra- 2/22/89 All holders of OLs
dation of Safety-Related or CPs for nuclear
Battery Cells power reactors.
OL
CP- Construction Permit
UNITED STATES
NUCLEAR REGULATORY COMMISSION FIRST CLASS MAIL
POSTAGE S FEES PAID
WASHINGTON, D.C. 20555 USNRC
PERMIT No. 0-47 OFFICIAL BUSINESS
PENALTY FOR PRIVATE USE. $300
IN 89-24 March 6, 1989 Production personnel were not involved in establishing nuclear safety limits
and were not familiar with the above-mentioned nuclear criticality accidents.
The safety training program has been revised to include selected accident
histories.
All involved personnel, including production operators, have reviewed all
procedures. Before startup of Areas 1, 2, and 3, procedures were revised to
include nuclear safety limits and controls. Procedures in other plant areas
will be revised to include safety limits.
Liquid scrap from Area 1 is now collected in favorable geometry containers.
After analysis, the solution is transferred to a favorable geometry quaran- tine tank for a second analysis. Then the solution is transferred to uniquely
identified favorable geometry containers, for transfer to the drums in Area 2.
Most 55-gallon drums in Area 2 have been eliminated by engineering redesign.
Barriers and other controls are in place to prevent unauthorized transfer of
drums into Area 3. Engineering studies are underway to eliminate or reduce
the use of all unfavorable geometry containers in Area 3.
No specific action or written response is required by this information notice.
If you have questions about this matter, please contact the technical contacts
listed below or the Regional Administrator of the appropriate regional office.
Richard E. Cunningham, Director
Division of Industrial and
Medical Nuclear Safety
Office of Nuclear Material Safety
and Safeguards
Technical Contacts: Gerald Troup, Region II
(404) 331-5566 George Bidinger, NMSS
(301) 492-0683 Attachment: List of Recently Issued NRC Information Notices
- SEE PREVIOUS PAGE FOR CONCURRENCE
OFC:IMUF:* IMUF:* IMSB:* DD/IMNS* D/IMNS*
NAME:GHBidinger: VLTharpe: LCRouse: GSjoblom: RECunningham:
DATE:2/24/89 2/21/89 :2/24/89 :2/24/89 :2/24/89 OFFICIAL RECORD COPY
IN 89- February , 1989 Production personnel were not involved in establishing nuclear safety limits
and were not familiar with the above-mentioned nuclear criticality accidents.
The safety training program has been revised to include selected accident
histories.
All involved personnel, including production operators, have reviewed all
procedures. Before startup of Areas 1, 2, and 3, procedures were revised to
include nuclear safety limits and controls. Procedures in other plant areas
will be revised to include safety limits.
Liquid scrap from Area 1 is now collected In favorable geometry containers.
After analysis, the solution is transferred to a favorable geometry
quarantine tank for a second analysis. Then the solution is transferred to
uniquely identified favorable geometry containers, for transfer to the drums in
Area 2.
Most 55-gallon drums in Area 2 have been eliminated by engineering redesign.
Barriers and other controls are in place to prevent unauthorized transfer of
drums into Area 3. Engineering studies are underway to eliminate or reduce the
use of all unfavorable geometry containers in Area 3.
No specific action or written response is required by this Information
Notice. If you have questions about this matter, please contact the technical
contacts listed below or the Regional Administrator of the appropriate
Regional Office.
Richard E. Cunningham, Director
Division of Industrial and
Medical Nuclear Safety
Office of Nuclear Material Safety
and Safeguards
Technical Contacts: Gerald Troup, Region II
(404) 331-5566 George Bidinger, NMSS
(301) 492-0683 Attachment: List of Recently Issued NRC Information Notices
EKraus-*fr'
OFC:IMUF: IMUF: IMD'$ N
~~~~~~-T---- --------
r _X,
---v3-----AdxJesa6P-
NAME:GH er: VLI9arpRouse: * om: R Fning
________________________________________ ____----------
DATE:2/a2489 :2kAL/89 :2/ 89 :2Uq-/89 :2/ 89 OFFICIAL RECORD COPY
IN 89- February , 1989 age 3 of 3 Liquid scrap from Area 1 is now collected in favorabl geometry containers.
After analysis, the solution is transferred to a fay.rable geometry
quarantine tank for a second analysis. Then the solution is transferred to
uniquely identified favorable geometry container4 for transfer to the drums in
Area 2. 7 Most 55-gallon drums in Area 2 have been eli nated by engineering redesign.
Barriers and other controls are in place t prevent unauthorized transfer of
drums into Area 3. Engineering studies e underway to eliminate or reduce the
use of all unfavorable geometry containers in Area 3.
No specific action or written response is required by this Information
Notice. If you have questions about this matter, please contact the technical
contacts listed below or the Regiohtal Administrator of the appropriate
Regional Office. /
Richard E. Cunningham, Director
Division of Industrial and
Medical Nuclear Safety
Office of Nuclear Material Safety
and Safeguards
Technical Contacts: Ge aId Troup, Region II
( 04) 331-5566 eorge Bidinger, NMSS
(301) 492-0683 Attachment: List Recently Issued NRC Information Notices
EKraus
OFC:IM Ig IMUF: IMSB- DD/IMNS D/IMNS
NAME:GHBi r> VLTI pe: L e: GSjoblom: RECunningham:
DATE:2 /89 :2/ "89 :2/ Z789 :2/ /89 :2/ /89
1 OFFICIAL'RECORD COPY
|
---|
|
list | - Information Notice 1989-01, Valve Body Erosion (4 January 1989)
- Information Notice 1989-02, Criminal Prosecution of Licensee'S Former President for Intentional Safety Violations (9 January 1989)
- Information Notice 1989-03, Potential Electrical Equipment Problems (11 January 1989)
- Information Notice 1989-04, Potential Problems from the Use of Space Heaters (17 January 1989)
- Information Notice 1989-05, Use of Deadly Force by Guards Protecting Nuclear Power Reactors Against Radiological Sabotage (19 January 1989)
- Information Notice 1989-06, Bent Anchor Bolts in Boiling Water Reactor Torus Supports (24 January 1989)
- Information Notice 1989-07, Failures of Small-Diameter Tubing in Control Air, Fuel Oil & Lube Oil Systems Render Emergency Diesel Generators Inoperable (25 January 1989)
- Information Notice 1989-08, Pump Damage Caused by Low-Flow Operation (26 January 1989)
- Information Notice 1989-09, Credit for Control Rods Without Scram Capability in the Calculation of Shutdown Margin (26 January 1989, Topic: Shutdown Margin)
- Information Notice 1989-10, Undetected Installation Errors in Main Steam Line Pipe Tunnel Differential Temperature-Sensing Elements at Boiling Water Reactors (27 January 1989)
- Information Notice 1989-11, Failure of DC Motor-Operated Valves to Develop Rated Torque Because of Improper Cable Sizing (2 February 1989, Topic: Shutdown Margin)
- Information Notice 1989-12, Dose Calibrator Quality Control (9 February 1989)
- Information Notice 1989-13, Alternative Waste Management Procedures in Case of Denial of Access to Low-Level Waste Disposal Sites (8 February 1989, Topic: Shutdown Margin, Authorized possession limits)
- Information Notice 1989-15, Second Reactor Coolant Pump Shaft Failure at Crystal River (16 February 1989, Topic: Shutdown Margin)
- Information Notice 1989-16, Excessive Voltage Drop in DC Systems (16 February 1989, Topic: Shutdown Margin, Battery sizing)
- Information Notice 1989-17, Contamination and Degradation of Safety-Related Battery Cells (22 February 1989)
- Information Notice 1989-18, Criminal Prosecution of Wrongdoing Committed by Suppliers of Nuclear Products or Services (24 August 1990)
- Information Notice 1989-20, Weld Failures in a Pump of Byron-Jackson Design (24 February 1989, Topic: Health Physics Network)
- Information Notice 1989-21, Changes in Performance Characteristics of Molded-Case Circuit Breakers (27 February 1989, Topic: Health Physics Network)
- Information Notice 1989-23, Environmental Qualification of Litton-Veam Cir Series Electrical Connectors (3 March 1989, Topic: Health Physics Network)
- Information Notice 1989-24, Nuclear Criticality Safety (6 March 1989, Topic: Health Physics Network)
- Information Notice 1989-25, Unauthorized Transfer of Ownership or Control of Licensed Activities (7 March 1989, Topic: Health Physics Network)
- Information Notice 1989-26, Instrument Air Supply to Safety-Related Equipment (7 March 1989, Topic: Health Physics Network)
- Information Notice 1989-27, Limitations on the Use of Waste Forms and High Integrity Containers for the Disposal of Low-Level Radioactive Waste (8 March 1989, Topic: Process Control Program)
- Information Notice 1989-28, Weight and Center of Gravity Discrepancies for Copes-Vulcan Air-Operated Valves (14 March 1989)
- Information Notice 1989-29, Potential Failure of Asea Brown Boveri Circuit Breakers During Seismic Event (15 March 1989)
- Information Notice 1989-30, High Temperature Environments at Nuclear Power Plants (1 November 1990)
- Information Notice 1989-31, Swelling and Cracking of Hafnium Control Rods (22 March 1989)
- Information Notice 1989-32, Surveillance Testing of Low-Temperature Overpressure-Protection Systems (23 March 1989, Topic: Stroke time)
- Information Notice 1989-33, Potential Failure of Westinghouse Steam Generator Tube Mechanical Plugs (23 March 1989)
- Information Notice 1989-34, Disposal of Americium Well-Logging Sources (30 March 1989)
- Information Notice 1989-35, Loss & Theft of Unsecured Licensed Material, Attachment 1 to NRC Information Notice 1990-014: Accidental Disposal of Radioactive Materials. (Also includes Attachments 2 & 3) (30 March 1989)
- Information Notice 1989-35, Loss & Theft of Unsecured Licensed Material, Attachment 1 to NRC Information Notice 1990-014: Accidental Disposal of Radioactive Materials. (Also Includes Attachments 2 & 3) (30 March 1989, Topic: Moisture-Density Gauge)
- Information Notice 1989-36, Excessive Temperatures in Emergency Core Cooling System Piping Located Outside Containment (4 April 1989)
- Information Notice 1989-37, Proposed Amendments to 40 CFR Part 61, Air Emission Standards for Radionuclides (4 April 1989)
- Information Notice 1989-38, Atmospheric Dump Valve Failures at Palo Verde Units 1, 2, and 3 (5 April 1989, Topic: Emergency Lighting)
- Information Notice 1989-39, List of Parties Excluded from Federal Procurement or Non-Procurement Programs (5 April 1989)
- Information Notice 1989-40, Unsatisfactory Operator Test Results and Their Effect on the Requalification Program (14 April 1989)
- Information Notice 1989-41, Operator Response to Pressurization of Low-Pressure Interfacing Systems (20 April 1989)
- Information Notice 1989-42, Failure of Rosemount Models 1153 and 1154 Transmitters (21 April 1989)
- Information Notice 1989-43, Permanent Deformation of Torque Switch Helical Springs in Limitorque SMA-Type Motor Operators (1 May 1989)
- Information Notice 1989-44, Hydrogen Storage on the Roof of the Control Room (27 April 1989, Topic: Coatings)
- Information Notice 1989-45, Metalclad, Low-Voltage Power Circuit Breakers Refurbished with Substandard Parts (8 May 1989, Topic: Commercial Grade Dedication, Coatings)
- Information Notice 1989-46, Confidentiality of Exercise Scenarios (11 May 1989, Topic: Coatings)
- Information Notice 1989-47, Potential Problems with Worn or Distorted Hose Clamps on Self-Contained Breathing Apparatus (18 May 1989, Topic: Coatings)
- Information Notice 1989-48, Design Deficiency in the Turbine-Driven Auxiliary Feedwater Pump Cooling Water Systems (22 May 1989, Topic: Coatings, Temporary Modification)
- Information Notice 1989-49, Failure to Close Service Water Cross-Connect Isolation Valves (22 May 1989, Topic: Coatings)
- Information Notice 1989-50, Inadequate Emergency Diesel Generator Fuel Supply (30 May 1989)
- Information Notice 1989-51, Potential Loss of Required Shutdown Margin During Refueling Operations (31 May 1989, Topic: Shutdown Margin, Coatings)
- Information Notice 1989-52, Potential Fire Damper Operational Problems (8 June 1989, Topic: Safe Shutdown, Shutdown Margin, Fire Barrier, Fire Protection Program)
... further results |
---|