Discusses Failure of First Periodic Type a Test on 770416-17 Due to Packing & Fitting Leaks During IE Insp 50-289/77-11. Recommends Either Interval Between Type a Tests Be Shortened or Type B & C Program Be Upgraded
ML19256D715
Person / Time
Site: Crane 
Issue date: 05/12/1977
From: Mccabe E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML19256D714 List:
References
NUDOCS 7910220630
Download: ML19256D715 (2)


Text

_

["

4,k UNI TED STATES f

fJUCLEAR REGULATOnY COMM10s!ON i

-

}

neman s

,.

x-

,j 631 PARK AVENUE S.,4 7,/ f xiNo or paussia, per4Nsvt.V ANI A 19406

,,,,.

Docket No. 50-289 MEMORANDUM FOR:

K. V. Seyfrit, Chief, Technical Assistance Branch IE:HQ THRU:

Cpje-E. J. Brunner, Chief, Reactor Operations and Nuclear f Support Branch, Region I FROM:

E. C. McCabe, Jr., Chief, Nuclear Support Section No.1, Reactor Operations and Nuclear Support Branch SUBJECT:

THREE MILE ISLAND 1 PERIODIC CILRT SCHEDULE (AITS F14545Hl)

Reference:

Inspection 50-289/77-11 Section III.A.6.(a) of Appendix J to 10 CFR 50 states that:

"If any periodic Type A test fails to meet thc applicable acceptance criteria in III.A.5.(b), the test schedule applicable to subsequent Type A tests will be reviewed and approved by the Commission".

Detail 8.a of the referenced report describes the initial failure of the first periodic Type A test (CILRT) at Three Mile Island-1 on April,16 and April, 17, 1977 The failure appears to be due to packing and fitting leaks corrected during the two day period.

Definitive analysis was precluded by repair of the leaks without prior local leak rate measurement and significant diurnal variations in the measured cor.tain-ment leak rate. To provide continued assurance of containment accept-ability between Type A tests, Region I recommends that either the inter-val between Type A tests be shortened or the Three Mile Island Type B and C testing program be upgraded to assure regular measurement and correction of possible leakage paths of the types identified during this and subsequent Type A tests. Also, this Type A test failure needs consideration when the exemptions from Appendix J, that this licensee has requested, are evaluated by the NRC.

P.G.1 % A E. C. McCabe, Jr., Chief Nuclear Support Section No.1 Enclosure: Office of Inspection and Enforcement Inspection Report Number 50-289/77-11 1453 116 7910220 h M

t,W 12 W

'

K. v. seyfrit

.

.

cc w/ encl:

F. A. Dreher, Region I Coordinator, IE:HQ 1453 117

.

.

.

j# "*%

-

e UNITED STATES

., ~

$

NuwLEAR REGULATORY COMM1ssi

.J

[ [9 +

j aEcton i e '. F

'.,g

-

631 PARK AVENUE a

Kina or enussia. eEnssytvania is4as

..

....

Docket No. 50-289 gg i g 1977 Metropolitan Edison Company ATTN: Mr. R. C. Arnold Vice President P. O. Box 542 Readihg, Pennsylvania 19603

.

Gentlemen:

Subject:

Inspection 50-289/77-11 This refers to the inspection conducted by Mr. J. Higgins of this office on April 4-19, 1977, at Three Mile Island Nuclear Station, Middletown, Pennsylvania, of activities authorized by NRC License No. OPR-50 and to the discussions of our findings held by Mr. Higgins with Mr. J. Colitz of your staff at the conclusion of the inspection, and to a subsequent telephone discussion between Mr. Higgins and Mr. E. Lawrence of your staff on April 20 and 21,1977.

Areas examined during this inspection are described in the Office of Inspection and Enforcement Inspection Report which is enclosed with this letter. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, observations by the inspector, and independent calculations by the inspector.

Based on the results of this inspection, it appears that one of your activities was not conducted in full ccmpliance with NRC requirements, as set forth in the Notice of Violation, enclosed herewith as Apper. dix A.

This item of nonccmpliance has been categorized into the levels as described in our correspondence to you dated December 31, '

This notice is sent to you pursuant to the provisions of Secti

. 201 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations.

Section 2.201 rcquires you to submit to this office, within twenty (20)

days of your receipt of this notice, a written statement or explanation in reply including:

(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further items of noncompliance; and (3) the date when full compli-ance will be achieved.

1453 118

,

D@

b

-

99/0/70797

_

_

Metropolitan Edison Company

MAY 121977 In accordance with Section 2.790 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosures will be placed in the flRC's Public Document Room.

If this report contains any information that you (or your contractor) celieve to be proprietary, it is necessary that you make a written application within 20 days to this office to withhold such information from public disclosure. Any such application must be accompanied by an affidavit executed by the owne af the information, which identifies the document or part sought to be withheld, and which contains a statement of reasons which addresses with specificity the items which will be considered by the Commission as listed in subparagraoh (b)(4) of Section 2.790. The information sought to be withheld shall be incorporated as far as pos-sible into a separate part of the affidavit.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, E do

. Brunner, Chief R

tor Operations and Nuclear S pport Branch Enclosures:

1.

Appendix A, Notice of Violation 2.

Office of Inspection and Enforcement Inspection Report Number 50-289/77-11 cc w/encls:

J. G. Herbein, Manager, Generation Operations - Nuclear J. J. Colitz, Unit 1 Superintendent R. W. Heward, Project Manager, GPUSC Miss Mary V. Southard, Chairman, Citizens for a Safe Environment (Without Report)

1453 119

.

.

-

..

.

Metropolitan Edison Company

g 1977

_

bec:

IE Mail a Fi'es (For Appropriate Distribution)

Central Files Public Document Roca (PDR)

local Public Docenent Roca (LPC2)

Nuclear Safety Information Centar (fiSIC)

Technical Information Center (TIC)

REG:I Reading Roca Region Directors (II, III. IV) (Report Only)

Comconwealth of Pennsylvania Miss Mary V. Southard, Chairman, Citizens for a Safe Environment 1453 120

.

e