ML19256D713

From kanterella
Jump to navigation Jump to search
Discusses Integrated Leakage Rate Test Schedule at Facility. Resommends Util Perform Type a Test within 12 Months of 1977 Test & More Frequent Type B & C Testing.Forwards IE Insp Rept 50-289/77-11
ML19256D713
Person / Time
Site: Crane Constellation icon.png
Issue date: 10/28/1977
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Goller K
Office of Nuclear Reactor Regulation
Shared Package
ML19256D714 List:
References
NUDOCS 7910220629
Download: ML19256D713 (2)


See also: IR 05000289/1977011

Text

, . ~ ,

-

'

L n L u e. %

-

.

$

"*

5

Docket No. 50-289

October 28, 1977

g

MEN RANDUM FOR: Karl R. Goller, A/D for Operaf.ing Peactors Division

of Operating Reactors NRR

i

l

FROM:

Karl V. Seyfrit, A/D for Technical, Programs, Division

of Reactor Operations Inspection', IE

SUBJECT:

THREE MILE ISLAND UNIT NO. 1 - INTEGRATED LEAKAGE

RATE TEST SCHEDULE

Metropolitan Edison Company performed an Integrated Leakage Rate Test

on April 16-17, 1977, for Three Mile Island Unit No.1. This test

failed to meet a ceptance criteria established in Appendix J to 10 CFR 50

and the Technical Specifications (TS). The test results are presented

in Region I's " Inspection Report 50-289/77-11" (enclosed) and the licensee's

" Reactor Containment Building Integrated Leak Rate Test April 1977" (sent

to NRR as an enclosure to a letter to R. Reid dated July 19,1977).

Pursuant to Appendix J Section III A.6 (a) and TS 4.4.1.1.6b, the licensee

has submitted for review and approvs1 a Type A testing schedule. The next

Type A test is proposed for the 1980 refueling outage as stated in the let-

ter to R. Reid. This would mean a minimum of 32 months between Type A tests

if testing is done January 1980. It is not apparent that the licensee has

been influenedd to modify either the testing interval or testing program

in view of the Type A test failure.

Local leakage rate tests were performed during the April 1977 outage. The

results of these tests indicated leakage 52.8%. greater than the acceptanca

criterion of 0.60 La. Type D and C tests performed in the June 1976 refuel-

ing outage also exceeded TS limits by 80.9%. Valve repairs made during the

April 1977 outage included both valves that were not repaired and some that

had been repaired in the June 1g76 outage. Type C testing is presently

{

scheduled for each refueling outage.

For both the 1974 Preoperational Integrated Leakage Rate Test (ILRT) and the

1977 Periodic ILRT, the combined local leakage rate from isolation valves

and penetrations was below 0.60 LA prior to the start of the ILRT. The sub-

j

sequent ILRTs were not ab?e to meet acceptance criteria without repairs being

made. Out concem is that Type B and C tests may not reveal the leak paths

,

{

that are seen in Type A testing.

I

I

1453

114

'

CCNTACT:

H. J. Wong

or R. E. Shewmaker

49-28180

49-27551

...

--.

7910220 h9

t

<

.

-a

. .

-.

Karl R. Goller

-2-

October 28,1977

-

.

  • The l'icensee has indicated in the 1977 leak rate test report that an evalu-

ation will be completed to determine suitable replacements for some gate

valves. Until changes are made and based on pmsent infomation, we recon-

mend that Metropolitan Edison Company be required to perfom a Type A test

within 12 months of the April 1977 test.

In addition, we also recomend

more frequent Type B and C testing to assure containment integrity within

the limits of Appendix J and TS.

Early resolution of this matter is requested for timely implementation of

any requirements that may be imposed by NRR.

i

/-

,,

.

f

'

Karl V. Seyf t

A/D for Technical Programs

<

Division of Reactor Operations

Inspection, IE

Enclosure:

IE Inspection Report 50-289/77-11

,

cc w/ enclosure:

R. W. Reid, NRR

f

y

.[}

h

,

,

W. R. Butler, NRR

C. I. Grimes, NRR

R. E. Shewesker, IE

cc w/o enclosure: E. J. Brunner, RI

'

E. C. McCabe, RI

>

Bistribution:

Central File

IE Files

IE Reading

1453

115

TP Reading

ROI Reading

H. Wong

,

e

fI WVCH f- /3/t

TP:R0:p

RCI:I

TP

IE

HWon

REShewmaker KVSey/77

frit

[

10/>>/M

10b/ /77

10/;i