IR 05000261/1987007

From kanterella
Jump to navigation Jump to search
Ack Receipt of & 870923 Amended Response Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-261/87-07
ML14175B486
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 10/08/1987
From: Herdt A
NRC Office of Inspection & Enforcement (IE Region II)
To: Utley E
Carolina Power & Light Co
References
NUDOCS 8710150452
Download: ML14175B486 (2)


Text

OCT 0 8 1987 Carolina Power and Light Company ATTN:

Mr. E. E. Utley Senior Executive Vice President Power Supply and Engineering and Construction P. 0. Box 1551 Raleigh, NC 27602 Gentlemen:

SUBJECT.:

NRC INSPECTION REPORT NOS. 50-261/87-07 Thank you for your response of July 14, 1987 and your amended response of September 23, 1987, to our Notice of Violation issued on June 19, 1987, concerning activities conducted at your Robinson facilit We have evaluated your response and found that it meets the requirements of 10 CFR 2.20 We will examine the implementation of your corrective actions during future inspection We appreciate your cooperation in this matte

Sincerely,

.

ORIGINAL SIGNED BY ALAN R. HRDT Alan R. Herdt,.Chief Engineering Branch Division of Reactor Safety cc:

G. P. Beatty, Jr., Vice President Robinson Nuclear Project Department R. E. Morgan, Plant General Manager bcc: NRC Resident Inspector Document Control Desk State of South Carolina RII RI-I RII Jtoley:lb Je 'ake PF edrickson 10/ 7/87 10/z./87 10/7 /87 8710150452 871008 PDR ADOCK 05000261 G

PDR

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8710150452 DOC.DATE: 87/10/08 NOTARIZED: NO DOCKET #

FACIL:50-261 H.B. Robinson Plant, Unit 2, Carolina Power & Light C 05000261 AUTH.NAME AUTHOR AFFILIATION DT, Region 2, Office of Director CIP.NAME RECIPIENT AFFILIATION LEY Carolina Power & Light C SUBJECT: Ack receipt of 870714 Itr informing NRC of steps taken to correct violation noted in Insp Rept 50-261/87-0 DISTRIBUTION CODE: IEO1D COPIES RECEIVED:LTR I ENCL -0 SIZE:

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-1 PD

ECCLESTON,K

INTERNAL: AEOD

DEDRO

NRR MORISSEAUD

NRR/DOEA DIR

NRR/DREP/EPB

NRR/DREP/RPB

NRR/DRIS DIR

NRR/PMAS/ILRB

OEEBI=ER AN, J I

OGC/HDS1

RE FL1 RES DEPY GI

Rf.27FILE

1 EXTERNAL: LPDR

NRC PDR

.

NSIC

T0 TOTAL NUMBER OF COPIES REQUIRED: LTTR

ENCL N