IR 05000206/1986010
| ML20203L084 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 08/07/1986 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | |
| Shared Package | |
| ML20203L077 | List: |
| References | |
| 50-206-86-10, 50-361-86-09, 50-361-86-9, 50-362-86-09, 50-362-86-9, NUDOCS 8608220380 | |
| Download: ML20203L084 (108) | |
Text
-
,_
%
,.,
Y i-
_
s
SALP. BOARD REPORT r,
, -
U.S.: NUCLEAR REGULATORY COMMISSION
REGION V
SYSTEMATIC ASSESSMENT OF LICENSEE PERFORMANCE.
50-206/86-10
'
50-361/86-09, -
50-362/86-09 SOUTHERN CALIFORNIA EDIS0N COMPANY SAN ONOFRE NUCLEAR GENRATING STATION UNITS 1, 2 AND 3 OCTOBER 1, 1984 THROUGH MAY 31, 1986-86082203eo e60ao7 PDR ADOCK 05000206 G
,
s
.
v.
' SUMMARY -' UNIT 1 Inspections Conducted *
Enforcement Items **
Functional Inspection Percent Severity Level Area Hours of Effort I
II III IV V
A.
Plant Operations 2575 48%
'
B.
Radiological 337 6%
Controls
,
C.
Maintenance 356 101
2
>
.
,
D.
Surveillance 364 7%
2 E.
Fire Protection
1%
F.
Emergency Prep.
189 13 %
1-G.
Security
1%;
H.
-Outage 906 17%
I.
Quality Programs /
301 6%
Administrative J.
Licensing Activities
-
-
K.
Training /Qualifi-
1%
cation Effectiveness
_
_
_ _
_
Totals 5200 100%
11 3***
Includes Inspection Report Nos. 84-24 through 86-22, 86-24, 86-25, and 86-27.
Severity levels are discussed in 10 CFR 2, Appendix C.
No deviations were identified during this SALP period.
- Violations and the units to which they apply are_ listed in Table 2.
Since some violations apply to more than one unit, the total of Tables 1A, IB, and 1C will exceed the number of violations listed in Table 2.
,
L
,
s...
.
.r:.
. _,
- -. - - - -.,, _,
,,
-m-
.
,,m
,
..y.-,---wr,--w
,t-
,-
,_,, - -,
_ - - - -. -. -
.
,
-
.
s TABLE IB INSPECTION ACTIVITIES AND ENFORCEMENT SUMMARY - UNIT 2 Inspections Conducted *
Enforcement Items **
Functional-Inspection Percent Severity Level Area Hours of Effort I
II III IV V
A.
Plant Operations 1486 44%
B.
Radiological 247
Controls C.
Maintenance 419 12%
D.
Surveillance 333 10%
1 E.
Fire Protection
1%
F.
Emergency Prep..
123 4%
1 G.
Security
3%
1-H.
Outages 289 8%
I.
Quality Programs /
239 7%
Administrative J.
Licensing Activities
-
-
1K.
Training /Qualifica-
3%
tion Effectiveness
_
_
_
_ _
Totals 3359 100%
11 2***
Includes Inspection Report Nos. 84-27 through 86-14 and 86-16 through
86-18.
Severity levels are discussed in 10 CFR 2, ' Appendix C.
No deviations were identified during this SALP period.
- ' Violations and the units to which'they' apply are: listed in Table 2.
Since some violations apply to more than pne unit, the total of. Tables 1A, 1B, and 1C will exceed the. number of violations listed in Table 2.
_
e
-
m--
%
-
--
,-%w-
-
r
-
-
.gf y
a p-W c
-.w r
q m -
.
-
.
-
_
..
.
I
.
,
TABLE IC INSPECTION ACTIVITIES AND ENFORCEMENT SUMMARY - UNIT 3 Inspections Conducted *
Enforcement Items **
Functional Inspection Percent Severity Level Area Hours of Effort
. I II III IV V
A.
Plant operations 1220 43%
B.
Radiological 286 10%
Controls C.
Maintenance 224 8%
D.
Surveillance 365 13%
E.
Fire Protection
1%
F.
Emergency Prep.
112 4%
1
.
G.
Security
2%
H.
Outages-246 9%
I.
Quality Programs /
187 7%
Administrative J.
Licensing Activities
-
-
K.
Training /Qualifica-
3%
tion Effectiveness
_. _
_
_
Totals 2796 100%
1***
,
- *
Includes Inspection Report Nos. 84-28 through 86-14 and 86-16 through 86-18.
Severity levels are discussed in 10 CFR 2, Appendix C.
No deviations were identified during this SALP period.
- Violations and the units to which they apply are listed in Table 2.
Since some violations apply to more than one unit, the total of Tables IA, IB, and 1C will exceed the number of violations listed in Table 2.
,
t
-._
_ _,.,, -..
.. -.,
,-
.. -.
_,.,y
,
, _.
~_,.,31--r rr-r-
'
r.
,
'
..
,~
- ,'
Table 2'
'
ENFORCEMENT ITEMS Inspection Applicable Severity Functional Report No.*
Subject Unit (s)
Level Area
'
206/84-28 Moisture seals were not 1.
IV I
installed in the conduit / cable runs'at the solenoids for the reactor head and pressurizer valves.
206/84-34 Three primary and six alternate 1,263 IV F
individuals who occupy supervisory positions in the emergency response organization had not received all of the required annual retraining.
206/84-34 Nonessential personnel were not 1,2&3 V
F reinstructed on the location of their new assembly area when the
_previously designated assembly area became unavailable.
206/85-06 Two intrusion alarms at Unit 1
IV G
were not being tested at least once every seven days.
206/85-09 Both doors of the personal escape 1 III C
airlock were open simulataneously.
206/85-09 The functional acceptability of
IV C
the interlock of the Unit 1 containment personnel escape airlock was not verified following maintenance.
361/85-12 The accessible AFW discharge
IV D
piping high point vents were not vented during the months of November and December of 1984 and January 1985.
361/85-12 A trip test of the steam driven
'2 V
D auxiliary feedwater pump was not conducted during the months of November and December of 1984 and January 1985.
361/85-12 Eighteen month surveillance to
IV-D verify battery capacity was not; accomplished on two batteries.
.
5
~
'
y i
N
^
_.
_
_. _ _ _
. _ _, _
.--
_ _. _, _. -
_
..
.
- -...
_
.
,..
g.
.
,
,
.
.
,
/
,
.
,
Inspection
_
' Applicable Severity Functional Report No.*
Subject
. Unit (s)
Level Area 206/85-13 Lower strength stainless steel-
-I IV C
-
studs replaced carbon steel body to bonnet stude without design reconciliation to determine if the new material would be satisfactory for service.
206/85-20 During a surveillance test,
IV D
operations personnel did not perform independent verification that a valve was locked open prior to shutting the valve.
206/85-26 The licensee IST program records
V D
and station engineering files did not have available a complete summary of corrective actions taken.
362/85-26 Two Construction Safety
IV I
Evaluations (CSE) did not document the bases for concluding that thechanges did not involve an unreviewed safety question.
206/85-30 Five separate violations dealing 1,2&3 IV I
with inadequate records to-(5 Items)
demonstrate proper environmental qualification of equipment.
206/85-33 Foreign material was
III C
introduced in the Unit 1 turbine-driven auxiliary feedwater pump oil sightglass; was not identified as a significant condition adverse to quality.
206/85-37 During setpoint testing of the
V D
ten Unit 1 main steam safety valves, the as-found setpoint-pressure was not documented for six out of the ten valves.
361/86-03 Inadequate security lighting in
IV G
protected area.
361/86-08 Failure to meet housekeeping 2,3 IV E
and fire protection requirements.
361/86-11 Improper installation of
IV C
temporary reactor vessel level indicator.
-
... -..-
-
-,,.
-. -. -
.,, -
.. -...,,,.. -,.-, -
.
.
..
,
.
'
.
Inspection Applicable Severity Functional Report No.*
Subject Unit (s)
Level Area 362/86-11 Inadequate operator attention
IV
- A to procedures and indications during reactor startup (involving early criticality and resulting
. reactor trip).
NOTE:
Three apparent violations were identifed in 206/86-07. Enforcement Action is pending.
Three apparent violations were identified in 206/86-17. Enforcement action is pending.
- When the violation is applicable to more than one unit, the report number for the lowest docket number is indicated.
.'
-
a
~ -
r
-
-m
.
..y
--.
,e.
,. - -
,
..
. -.. _.
_
_
.
'f.'
-
..
l; *'
'
TABLE 3A - UNIT 1-SYNOPSIS OF LICENSEE EVENT REPORTS-(LER's)-
1.
Functional SALP Cause Code +
l
' Area A
B.
C D-E X
Totals A..
-Plant Ops.
1
4
-10 B.
= Rad. Controls
1 1:
C.
Maintenance.
2
6
'1 D.
Surveillance
1.
4
,
E.
Fire Protection
1 i
F.
G.
Security-
,
H.
Outages
' I.
Quality / Admin
1 J.
Licensing
K.
Training / Qual.
O.
Effectiveness-
'~
Totals
5 0'
8
'1'
+
'
A - Personnel Error
.
l -
B - Design, Manufacturing or Installation Error C - External Cause D - Defective Procedures
,
E - Component Failure
,
,
X - Other
'
- - Cause not yet determined i
The above data are based upon the LER's-84-08 and 84-10 through-86-06.
'
s
'
>
b a
f
. _,. -
, - - -._..
- _ -, _.. -, _. -
.
. - -
- - -. - - - -
- - - -- - - -,.--.-.- - - - ------
-
-
-
.
.
-
t j
.
.
TABLE 3B - UNIT 2 SYNOPSIS OF LICENSEE EVENT REPORTS-(LER's)
J
~
Functional SALP Cause Code +
,
Area A
B C
D E
X,-
Totals A.
Plant Ops.
30
-17
'2
' 60'
,
B.-
Rad. Controls
3
. 2
- C.
Maintenance-
1
1
D.
Surveillance
1
3-15
'
E.
Fire Protection
l'
,
.
.
F.
G.
Security
1 H.-
Outages
"2
I I.
Quality / Admin.
O
,
J.
Licensing
1 K.
Training / Qual.
.
.--
4 Effectiveness
'
-
Totals
. 36-
12
,25, 0
'3 100
<
'
'
A - Personnel Error i
B - Design, Manufacturing or Installation: Error C - External Cause i
D - Defective Procedures
'
E - Component Failure X - Other
.
- - Cause not yet determined The above data are based upon LER's 84-49 through 86-08.
i
d
-#-.7 yg
-
%,,
.-.4w-~.
_.w
-
w.
- ,
._ -
.+-g~m_
y
-.g--g
,y,m-m.m y
.
-.%
p gwp-g,pg,.
,,w,-w.9-.-----,-.g
-
e,.,---
t-*
9u
.
-
,.
-
-
_.
.-
_
7,,
'
',..
's
'
..,
_
'
..;s.
..
,
,~
.
' * *
473'
'
.
.o.
',
,,
.
i TABLE 3C - UNIT 3 t
t
, 1 SYNOPSIS OF LICENSEE EVENT REPORTS (LER's)
Functional.
SALP Cause Code +
Area A_
B_ -
C, D,
E_
X_
.
Totals
._
A.'
Plant Ops.
10
1
35 B.
Rad. Controls
- 1-
2'
C.
Maintenance
1
3 D.
Surveillance
l'
10 E.'
Fire Protection 1-
F.
.
G.
Security
H.
Outages
1-
I.
Quality / Admin 0-J.
. Licensing
^
..
K.'
Training / Qual.
Effectiveness Totals
10
2
1
53
.
+
A - Personnel Error B - Design, Manufacturing or Installation Error C - External Cause D - Defective Procedures E - Component Failure X -- Other
- - Cause not yet determined
.The above data are based upon LER's 84-35 through 86-06.
.
~
'k, * *
x
-
.
p.
.s
,s
.,.. -
.
5
'
.
o.
,
t AE00 INPUT TO SALP REVIEW FOR SAN ON0FRE 1, 2 AND 3 Introduction In order to evaluate the overall quality of tne contents of the Licensee Event Reports (LERs) submitted by San Onofre 1, 2 and 3 during the October 1, 1984 to March 31, 1986 Systematic Assessment of Licensee Performance (SALP) assessment period, a representative sample of each unit's LERs was evaluated using a refinement of the basic methodology presented in NUREG/CR-4178.1 The sample consists of a total of 30 LERs for the station (i.e., 5 LERs for San Onofre 1,17 for San Onofre 2, and 8 for San Onofre 3). Thirty is considered to be the maximum number of LERs required to be evaluated for each station during an assessment period. San Onofre LERs were evaluated as one sample because it was determined that their LERs are both written and formally reviewed at the station, rather than unit, level. See Appendix A for a list of the LER numbers in the sample.
It was necessary to start the evaluation before the end of the SALP assessment period because the input was due such a short time after the end j
of the SALP period. Therefore, not all of the LERs prepared during the SALP assessment period were available for review.
Methodology The evaluation consists of a detailed review of each selected LER to determine how well the contenc of its text, abstract, and coded fields meet
3
the reauirements of NUREG-1022, and Supplements 1 and 2 to NUREG-1022.
The evaluation prcress for each LER is divided into two parts. The first part of the evaluation consists of documenting comments specific to the content and presentation of each LER. The second part consists of determining a score (0-10 points) for the text, abstract, and coded fields
' of each LER.
l l
l
_
.__._. _ _ _
___. _. _ _,
__
_
p
.
c
.
',
,
The LER specific comments serve two purposes:
(1) they point out what the analysts considered to be the specific deficiencies or observations concerning the information pertaining to the event, ano (2) they provice a basis for a count of general deficiencies for the overall sample of LERs that was reviewed. Likewise, the scores serve two purposes:
(1) they serve to illustrate in numerical terms how the analysts perceived the content of tne information that was presented, and (2) they provide a basis for the overall score determined for each LER. The overall score for each LER is the result of combining the scores for the text, abstract, and coded fields (i.e., 0.6 x text score + 0.3 x abstract score + 0.1 x coded fields score = overall LER score).
The results of the LER ouality evaluation are divided into two categories:
(1) detailed information and (2) summary information. The detailed, information, presented in Appendices A through D, consists of LER sample information (Appendix A), a table of the scores for each sample LER ( Appendix B), tables of the number of deficiencies and nbservations for the text, abstract and coded fields (Appendix C), and comment sheets containing narrative statements concerning the Contents of each LER ( Appendix D).
When referring to these appendices, the reader is cautioned not to try to directly correl. ate the number of comments on a comment sheet with the LER
\\
scores, as the analyst has flexibility to consider the magnitude of a deficiency when assigning scores.
Although the purpose of this evaluation was to assess the content of the individual LERs selected for review, the analysts of ten make other observations which they believe should be brought to the attention of the licensee. The following discussion addresses a general observation that was noted during the evaluation.
General Observation During the sample selection process, it was notea that 66 of 148 LERs on file for SALP period October 1, 1984 through March 31, 1986, were submitted without a text. Submittal of an LER without a text is
-
o
.
i.
acceptable, however the abstract must then meet all of the requirements of a text and still be less than 1400 characters.
Generally, only a simple event can be presented in the limited abstract field and still meet all the reauirements for a text. The twelve LERs in the audit sample submitted without a text had an average text score of only 7.6, while the 18 LERs in the audit sample submitted with a text had an average text score of 8.5.
The overall average was good compared to other units, but it might have been even higher had more LERs been submitted with a text.
Discussion of Results
.
A discussion of the analysts' conclusions concerning LER auality is presented below. These conclusions are based solely on the results of the evaluation of the contents of the LERs selected for review and as such represent the analysts' assessment of the stations performance (on a scale of 0 to 10) in submitting LERs that meet the reouirements of 10 CFR 50.73(b). San Onofre 1, 2 and 3 LERs were evaluated as one sample, rather than three separate samples, because it was determined that the San Onofre LERs are,both written and formally reviewed at the station, rather y
than the unit, level.
Table 1 presents the average scores for the sample of LERs evaluated for San Onofre 1, 2 and 3.
The reader is cautioned that the scores resulting from the methodology used for this evaluation are not directly comparable to the scores contained in NUREG/CR-4178 due to refinements in the methodology.
In order to place the scores provided in Table 1 in perspective, the scores from other licensees that have been evaluated using the current methodology are provioed in Table 2.
Additional licensees are added to Table 2 as they are evaluated. Table 3 and Appendix Table B-1 provide a summary of the information that is the basis for the average scores in Table 1.
For example, San Onofre's average score for the text of the LERs that were evaluated was 8.1 out of a possible 10 points. From Table 3 it can be seen that the text score actually results from the review
~ and evaluation of 17 different requirements ranging from the discussion of
-
_
._,.
_
_.
_. _ _ _
. _ -.
,
.
.
.
a TABLE 1.
SUMMARY OF SCORES FOR SAN ON0FRE 1, 2, 3 Average High Low Text 8.1 9.5 5.9 Abstract 9.1 9.9 7.7 Coded Fields 9.0 10.0 7.4 b
Overall 8.5 9,4 7,)
a.
See Appendix B for a summary of scores for each LER that was evaluated.
b.
Overall Average = 60% Text Average + 30% Abstract Average + 10% Coded Fields Average.
.
O
'
s e
.
-
- -
-m
.r
-- - -. - -.--
.,-.,-,--m
- - -
.--w
-
-
.--
- - - - -. - - -
-,-.,m
-
- - -
-
--
/.
,
.
'
"A3:.;E 2:
AVE 3AG3 SCO33 C O k P A R :: S O X
-
~
.
'
g_
.
B-
-
I v2 H
'7-
7
/
/
'
6-
/
/
-
%
'
/
/
/
%
.
/
/
/
O'
5-
/
/
r
/
,
/
/
/
/
/
g rol 4_
So~ O~oco.t 2 + 3
/
/
/
/
/
tQ
/
/
/
/
/
N
/
/
/
/
/
U 3-r /
/
/
/
/
/
/ /
/
/
/
/
/
/ /
/
/
/
/
g_
/
/ /
/
/ /
/
/
/
,
/
/ /
/
/ /
/
/
/
.
.
1-re
/ r / /
/
/ / r /
/
/
e r
r e
r
/ /
/ / / /
/ / / / / / / / / /
/
/
/ /
/ / / /
/ / / / / / / / / /
/
/
-
i i. i i i i i i i i i i i i i i i i i iiiiiiiiiiiiiiiii 9.5 9.0 B.5, 8.0 7.5 7.0 6.5 6.0
,
GRADE
.
.
- O o
.
TABLE 3.
LER REQUIREMENT PERCENTAGE SCORES FOR SAN ON0FRE 1, 2, 3 TEXT
-
Percentage Reauirements [50.73(b)] - Descriptions Scores ( )'
(2)(ii)(A) - - Plant condition prior to event 77 (30)
(2)(ii)(B) - - Inoperable eauipment that contributed b
(2)(ii)(C) - - Date(s) and approximate times 92 (30)
(2)(ii)(D) - - Root cause and intermediate cause(s)
92(30)
(2)(ii)(E) - - Mode, mechanism, and effect 100 (11)
(2)(ii)(F) - - EIIS Codes 98 (30)
(2)(ii)(G) - - Secondary function affected b
(2)(ii)(H) - - Estimate of unavailability 93 (7)
(2)(ii)(I) - - Method of discovery 95 (30)
(2)(ii)(J)(1) - Operator actions affecting course (2)(ii)(J)(2) - Personnel error (procedural deficiency)
100(4))
90 (12 (2)(ii)(K) - - Safety system responses 81 (18)
'
(2)(ii)(L) - - Manufacturer and model no information 11 (11)
(3)
,---- Assessment of safety conseauences 84(30)
(4)
Corrective actions 87 (30)
(5)
Previous similar event information 22(30)
(2)(i) - - - - Text presentation 74 (30)
.
j ABSTRACT Percentage Reauirements [50.73(b)(1)] - Descriptions Scores ( )a
- Major occurrences (Immediate cause and effect 100 (30)
information)
- Description of plant, system, component, and/or 97 (15)
personnel responses
- Root cause information 92 (30)
- Corrective Action information 90 (30)
- Abstract presentation 80(30)
-
--r F ee W9-4Ti
-
- -' m-t ra mw i w--yw-re
-
-
.
,
'
.
TABLE 3.
(continued)
CODED FIELDS Percentage Item Number (s) - Description Scores ( )a 1, 2, and 3 - Facility name (unit no.), docket no. and 100(30)
page number (s)
4 - - - - - - Title 64(30)
5, 6, and 7 - Event date, LER No., and report date 99 (30)
8 - - - - - - Other f acilities involved 97 (30)
9 and 10 - - Operating mode and power level 100 (30)
11-----
Reporting reauirements 98(30)
12 - - - - - Licensee contact information 100(30)
13 - - "- - Coded component failure information 96 (30)
14 and -15 - - Supplemental report information 97 (30)
a.
Percentage scores are the result of dividing the total points for a reouirement by the number of points possible for that reauirement.
(Note: Some reouirements are not applicable to all LERs, therefore, the z
number of points possible was adjusted accordingly.) The number in parenthesis is the number of LERs for which the reauirement was considered applicable, b.
A percentage score for this reauirement is meaningless as it is not possible to determine from the information available to the analyst whether this reouirement is applicable to a specific LER.
It is always given 100%
if it is provided and is always considered "not applicable" when it is not.
.
. -.. - -.
-
, -. -.. _. _ _ ~ _. -
- _
_,,,_,__m
.._._,
.
.
i.
plant operating conditions before the event [10 CFR 50.73(b)(2)(ii)(A)] to text presentation. Tne percentage scores in the text summary section of Table 3 provide an indication of how well each text reauirement was addressed by the licensee for the 30 LERs that were evaluated.
Discussion of Specific Deficiencies A review of the percentage scores presented in Table 3 will auickly point out where the San Onofre station is experiencing the most difficulty in preparing LERs. For example, requirement percentage scores of less tnan 75 indicate that the licensees probably need additional guidance concerning these reauirements. Scores of 75 or above, but less than 100, indicate that the licensees probably understand the basic reouirement but has either: (1) excluded certain less significant information from most of the discussi_o,ns concerning that reouirement or (2) totally f ailed to address the reauirement in one or two of the selected LERs. The licensees should review the LER specific comments presented in Appendix D in order to determine why a less than perfect score was received for certain reauirements. The text reouirements with a score of les5. than 75 are discussed below in their order of importance.
In addition, the primary deficiencies in,the abstract and coded fields are discussed.
T The manufacturer and model number (or other uniaue identification) was not provided in the text of ten of the eleven LERs that involved a component f ailure, Reauirement 50.73(b)(2)(ii)(L). Such information is important in that it can lead to the identification of possible generic problems in the industry.
Although the score (77%) was marginally acceptable, twelve of 30 LERs did not provide adeauate information concerning the operating conditions just prior to the event, Reauirement 50.73(b)(2)(ii)(A). One LER failed to provide any information concerning operating conditions. The most common deficiency was however, the failure to define the operating mode that was provided. Mode definitions are not standardized to the point that a
..
- -.
--
__
-_ - - -. -
.o
.
.
o
'.
definition would be redundant to the reader. Sufficient information should be provided early in the discussion so that the reader has a reference point in terms of the possible effects on the plant.
Twenty of 30 LERs did not include previous similar event information, Reauirement 50.73(b)(5). While it may be difficulty to identify previous similar events, references to known previous similar events at the respective plant are reouired.
If no previous similar events are known, the text should so state.
The text presentation score of 74% is generally low. As discussed in the General Observations this was due to the large number of LERs submitted without a text. The space limitation of the abstract section does not allow for the necessary detail except for very simple events.
The main deficiency in the area of coded fields involves the title, Item (4). Twenty-three of the titles did not indicate root cause, nine f ailed to include the link (i.e., circumstances or conditions which tie the root cause to the result), and two failed to provide information concerning the result of the event (i.e., why the event was reouired to be reported).
While result is. considered the most important part of the title, cause and N
link must be included to make the title complete. An example of a title that only addresses the result might be " Reactor Scram". This is inadeouate in that the cause and link are not provided. A more appropriate title might be " Inadvertent Relay Actuation During Surveillance Test LOP-1 Causes Reactor Scran". From this title the reader knows the cause involved either personnel or procedures and testing Contributed to the event.
Table 4 provides a summary of the areas that need improvement for San Gnofre LERs. For more specific information concerning deficiencies the reader should refer to the information presented in Appendices C and D.
General guidance concerning these reouirements can be found in NUREG-1022, Supplement No. 2.4
-.
--
. _ _
.
'
.
B a TABLE 4.
AREAS MOST NEEDING IMPROVEMENT FOR SAN ON0FRE LERs Areas Comments Manufacturer and model number Component identification information'
information (manufacturer and model number)
should be included in the text for each failed component or whenever a component is suspected of contributing to the event because of its design.
Operating conditions prior to Details such as power level, mode the event names and in some Cases, temperatures and pressures are reouired in the text.
Previous similar events Previous similar events should be
'
referenced (e.g., by LER number) or if none are identified, the text
"
should so state.
Text presentation Improvement in text presentation would result from submitting separate text and abstract sections.
Coded fields a.
Titles Titles should be written such that
'
they better describe the event.
In N
particular, include the root cause and result of the event and the link between them in all titles.
!
-
,.-,-.
- - - - -. -.
, _
_, - - -,
,
,
_
.
.
O e REFERENCES 1.
B. S.' Anderson, C. F. Miller, B. M. Valentine, An Evaluation of Selected Licensee Event Reports Prepared Pursuant to 10 CFR 50.73 (DRAFT), NUREG/CR-4178, March 1985.
2.
Office for Analysis and Evaluation of Operational Data, Licensee Event.
Report System, NUREG-1022, U.S. Nuclear Regulatory Commission, September 1983.
3.
Office for Analysis and Evaluation of Operational. Data, Licensee Event Report System, NUREG-1022 Supplement No.1, U.S. Nuclear Regulatory Commission, February 1984.
4.
Office for Analysis and Evaluation of Operational Data, Licensee Event Report System, NUREG-1022 Supplement No. 2 U.S. Nuclear Regulatory Commission, September 1985.
.,
e O
-
,_,, _
_
_ _ _ _ _ - _ -. - - - _ _ - -. _, _ _
,
__.-__-______,,,,,.c
- -,,
.
,
's APPENDIX A LER SAMPLE SELECTION INFORMATION FOR SAN ONOFRE 1, 2 AND 3
.,
e
,
-
-- _
.
.
..
TABLE A-1.
LER SAMPLE SELECTION FOR SAN ON0FRE 1, 2, 3 i
LER Sample Number Unit Number LER Number Comments
1 84-012-00
1 84-014-01
1 84-015-00 ESF
1 85-004-00
1 85-014-00 SCRAM
2 84-072-00 g
2 84-079-01
2 85-008-00
.
j!
85-011-00 ESF
2 85-018-00 SCRAM
.
2 85-021-00 ESF i
2 85-022-00 ESF
2 85-024-00 SCRAM
2 85-028-00 SCRAM
2 85-031-00 SCRAM
2 85-035-00
2 85-040-00 ESF
2 85-044-00 ESF
2 85-046-01 SCRAM
2 85-052-00 ESF
2 85-053-00
2 85-054-00
3 84-040-00 SCRAM
3 85-004-00
..
-- -
_... _., _ _,,,. _ _.. _,, _ _ -
_ _ _ _ _...
._
_ _ _..., -,
-, - -
-+
c
-...-,
. - -
..
-
.
.... -
.*
.
-..
TABLE A-1.
(continued)
LER Sample Number Unit Number LER Number Comments
!
3 85-006-00 ESF
3 85-008-00 SCRAM
3 85-017-01
3 85-019-01 ESF
3 85-027-00 ESF
3 85-028-00 ESF
,_
..
O
\\
.
!
..
p,e--
.- - - - -,
---,
,7.-m
.g7,,n, nm,-7--mgm-
., - - - - - - + - -,, -
.,w
,. -..
,_,,,n.,,,,,,
, - -.----
-.
,.,-,-,,--m--
-+ - - -
a
.
.
..
-
<
APPENDIX B_
_
EVALUATION SCORES OF INDIVIDUAL LERs FOR SAN ON0FRE 1, 2 AND 3
-.
e e
..
_. _ _ - -
.. - -..-
- -
-
- _-.
-
..
--.. -.
..
.
/.
,
.
-
i TABLE 8-1.
EVALUATION SCORES OF IMOIVIDUAL LERs FOR SAN ONOFRE 1, 2. 3
.
.
LER Sample Number'
2
4
6
8
10
12
14
16
,
I Text 9.5 9.2 8.2 8.2 9.1 8.4 8.8 7. 9 9.1 8.6 7.1 8.3 7.6 7.4 7.2 8.3
!
Abstract 9.5 9.6 9.4 9. 8 9.7 9.1 8. 8,
7. 7 9.9 9.4 8.1 9.5 8.9 8.0 9.1 9. 8
!
Coded Fields 9.0 8.5 9.0 7.4 8.5 8.5 9.0 8.5 8.5 9.7 8.5 9.0 9.3.
9.4 9.5 9.0
j Overall 9.4 9.3 8.6 8.6 9.2 8.6 8.8 7. 9 9. 2 8. 9 7. 6 8. 7 8.2 7.8 8.0 8.8
!
l LER Sample Number *
'
18
20
22
24
26
28
30 AVERAGE l
Text 8. 8 5.9 8. 0 6.5 9.0 7. 9 7. 7 7. 0 8.6 9.1 9.2 6.8 8.7 8.3 8.1 Abstract 9.7 8.8 9.3 7.9 9.9 9.4 9.2 8.8 8.9 8.1 9.7 8.1 9.6 9.9 9.1 Coded j
Fields 10.0 9.3 9.5 10.0 9.0 9.2 8.5 9.5 8.5 9.3 9.5 8.5 9.0 8.5 9.0 Overall 9.2 7.1 8.5 7.3 9.3 8.5 8.3 7. 8 8. 7 8.8 9.4 7. 3 9.0 8.8 8.5
.
.,
I See Appendix A for a list of the corresponding LER numbers.
a.
1
4
e
_ _ _ - _ _ _,
.
.
.
APPENDIX C DEFICIENCY AND OBSERVATION COUNTS FOR SAN ON0FRE 1, 2 AND 3
.,
,
-
,
e
.
..
.
_.
.
-
-
....
.-
_.
.
-
.
'
'
'
TABLE C-1.
TEXT DEFICIENCIES AND OBSERVATIONS FOR SAN ON0FRE 1, 2, 3
'
Number of LERs with
-
Deficiencies and
.
Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)b a
50.73(b)(2)(ii)(A)--Plant operating 13 (30)
{
conaitions perore the event were not i
included or were inadequate.
50.73(b)(2)(ii)(B)--Discussion of the status 0 (8)
of the structures, components, or systems that were inoperable at the start of the a
event and that contributed to the event was
not included or was inadeauate.
50.73(b)(2)(ii)(C)--Failure to include 5 (30)
sufficient date and/or time information.
,
a.
Date information was insufficient.
b.
T-ime information was insufficient.
I 50.73(b)(2)(ii)(D)--The root cause and/or 8 (30)
Intermeaiate tallure, system failure, or personnel error was not included or was
'
inadeauate.
i
~
a.
Cause of component failure was not
j\\
included or was inadeauate
.
.
b.
Cause of system failure was not
'
included or was inadeauate c.
Cause of personnel error was not
included or was inadequate.
50.73(b)(2)(ii)(E)--The failure mode, 0 (11)
mechanism (immediate cause), and/or effect (consecuence) for each failed component was
'
not included or was inadeauate.
l a.
Failure mode was not included or was
inadeauate l
b.
Mechanism (immediate cause) was not included or was inadeauate i
c.
Effect (consecuence) was not included i
or was inadeauate.
,
l l
l
[
t
-
--
.
.
--
- -.
.
-.
.
. -
-
.
,'
.
.
.
.
TABLE C-1.
(continued)
Number of LERs with
'
Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)D a
50.73(b)(2)(ii)(F)--The Energy Industry 1(30)
Identification System component function identifier for each component or system was not included.
50.73(b)(2)(ii)(G)--For a f ailure of a 0 (1)
component witn multiple functions, a list of systems or secondary functions which were also affected was not included or was inaceauate.
50.73(b)(2)(ii)(H)--For a f ailure that 1 (7)
rendereo a train of a safety system inoperable, the estimate of elapsed time from the discovery of the failure until the train was returned to service was not included.
50.73(b)(2)(ii)(I)--The method of discovery 1 (30)
of each component failure, system failure,
-
j personnel error, or procedural error was not included or was'inadeauate.
,
a.
Method of discovery for each
component failure was not included or was inadeouate b.
Method of discovery for each system
l failure was not included or was inadeauate i
~ Method of discovery for each I
l c.
personnel error was not included or was inadeauate d.
Method of discovery for each
procedural error was not included or was inadeauate.
-
-
-
._ _
..
- -
-
_
. _ _ -
-
_ _ _ _. ___
.
.
_ _ -.
_
.
,"
.
..
.
TABLE C-1.
(continued)
Number of LERs with
-
Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)b a
50.73(b)(2)(ii)(J)(1)--Operator actions that 0 (4)
attected the course of the event including operator errors and/or procedural deficiencies were not included or were inadeauate.
50.73(b)(2)(ii)(J)(2)--The discussion of 4 (12)
each personnel error was not included or was inadeauate, a.
OBSERVATION: A personnel error was
implied by the text, but was not explicitly stated.
-
b.
50.73(b)(2)(ii)(J)(2)(1)--Discussion
as to whether the personnel error was cognitive or procedural was not included or was inadeouate.
c.
50.73(b)(2)(ii)(J)(2)(ii)--Discussion
as to whether the personnel error was contrary to an approved procedure, was a direct result of an error in an approved ' procedure, or was associated
\\
with an activity or task that was not covered by an approved procedure was not included or was inadeauate.
d.
50.73(b)(2)(ii)(J)(2)(iii)--Discussion
of any unusual characteristics of the work location (e.g., heat, noise) that directly contributed to the personnel error was not included or was inadequate, e.
50. 73 ( b) ( 2 ) ( i i ) ( J ) ( 2 ) ( i v )--D i s c u s e'. nt
of the type of personnel involv:L (i.e., contractor personnel tPrlit-licensed operator, utility act. ige. e d operator, other utility personnel) was not included or was inadeouate.
l l
l
_ _ _
__
. _,
_
.. _ _
_
._.
_
.
.
.
.
'
.
.
.
.
TABLE C-1.
(continued)
~
Number of LERs with Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)b a
50.73(b)(2)(11)(K)--Automatic and/or manual 6 (18)
safety system responses were not included or were inadeauate.
50.73(b)(2'(ii)(L)--The manufacturer and/or 10 (11)
)
moael number of each failed component was not included or was inadeauate.
50.73(b)(3)--An assessment of the safety 10 (30)
ccnseauences and implications of the event was not included or was inadeauate.
a.
OBSERVATION: The availability of
other systems or components capable of mitigating the conseauences of the event was not discussed.
If no other systems or components were available, the text should state that none existed.
b.
OBSERVATION: The consecuences
'of the event had it occurred under more severe conditions were not
\\
discussed.
If the event occurred under what were considered the most severe conditions, the text should so state.
50.73(b)(4)--A discussion of any corrective 9 (30)
actions planned as L result of the event including those to reduce the probability of similar events occurring in the future was not included or was inadeouate.
.. - _ _ _ _
_
_
.
_
- _..
,.
.
,'
.
..
.
TABLE C-1.
(continued)
'
Number of LERs with Deficiencies and
Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)b a
a.
A discussion of actions reauired to
correct the problem (e.g., return the component or system to an operational condition or correct the personnel error) was not included or was inadeauate.
b.
A discussion of actions reauired to
reduce the probability of recurrence of the problem or similar event (correct the root cause) was not included or was inadeauate.
c.
OBSERVATION: A discussion of actions
reauired to prevent similar failures in similar and/or other systems (e.g.,
correct the faulty part in all components with the same manufacturer and model number) was not included or was inadeauate.
50.73(b)(5)--Information concerning previous 21(30)
similar events was not included or was inadeauate.
\\
.. -
--.
.
_.
..
_ _ _.. _
_
_
.
.
.
,
..
TABLE C-1.
(continued)
-
-
Number of LERS with Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)D a
50.73(b)(2)(i)--Text presentation 3 (30)
inaaeauacies, a.
OBSERVATION: A diagram would have
aided in understanding the text discussion.
b.
Text contained undefined acronyms
and/or plant specific designators.
c.
The text contains other specific
deficiencies relating to the readability.
..
a.
The "sub-paragraph total" is a tabulation of specific deficiencies or observations within certain reauirements. Since an LER can have more than one deficiency for certain reouirements, (e.g., an LER can be deficient in the area of both date and time information), the sub-paragraph totals do
't necessarily add up to the paragraph total.
b.
The " paragraph total" is the number of LERs that have one or more reauirement deficiencies or observations. The number in parenthesis is the N
number of LERs for which the reauire7,ent was considered applicable.
,..
_ _..-.
_
_ _ _
. __
.
.. -,. _
--
-..
.__
- _ _ _ __________
'
-
.
,
.
.
TABLE C-2.
ABSTRACT DEFICIENCIES AND OBSERVATIONS FOR SAN ON0FRE 1, 2, 3
_
Number of LERs with
-
Deficiencies and Observatiors Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)b a
A summary of occurrences (immediate cause 0 (30)
and effect) was not included or was inadeauate A summary of plant, system, and/or personnel 1 (15)
responses was not included or was inadeauate.
a.
Summary of plant responses was not
included or was inadeauate.
b.
Summary of system responses was not
included or was inadeauate.
c.
Summary of personnel responses was not
included or was inadeouate.
A summary of the root cause of the event 6 (30)
was not included or was inadeauate.
A summary of the corrective actions taken or 6 (30)
planned as a result of the event was not included or was inadeauate.
,
- - ~ - -
m
--
sm-~
e u
.
>
,
.
TABLE C-2.
(continued)
-.
Number of LERs with Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)D a
Abstract presentation inadeauacies 6 (30)
a.
OBSERVATION: The abstract contains
information not included in the text.
The abstract is intended to be a summary of the text, therefore, the text should discuss all information summarized in the abstract.
b.
The abstract was greater than
1400 characters c.
The abstract contains undefined
acronyms and/or plant specific ddsignators.
d.
The abstract contains other specific
deficiencies (i.e., poor summarization, contradictions,etc.)
a.
The "sub-paragraph tota!" is a tabulation of specific deficiencies or observations within certain requirements. Since an LER can have more tnan one deficiency 'for certain requirements, (e.g., an LER can be deficient in i
the area of both date and time information), the sub-paragraph totals do not necessarily add up to the paragraph total.
b.
The " paragraph total" is the number of LERS that have one or more deficiency or observation. The number in parenthesis is the number of LERs for which a certain reauirement was considered applicable.
,
- - -,
,
,y-
,p
- - - - - --- - - - -. - -,..,
.
-
,p.--
, --.
. - - -
, - - - -
._
_ _
_
_
. _. -.
.
,
i
.
.
TABLE C-3.
CODED FIELDS DEFICIENCIES AND OBSERVATIONS FOR SAN ON0FRE 1, 2, 3
-
.
Number of LERs with Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)D a
j Facility Name 0 (30)
a.
Unit number was not included or incorrect'.
b.
Name was not included or was incorrect.
c.
Additional unit numbers were included but not required.
s Docket Number was not included or was 0(30)
incorrect.
,
Page Number was not included or was 0 (30)
incorrect.
- !
Title was left blank or was inadeauate 25(30)
a.
Boot cause was not given in title
b.
Resu!t (effect) was not given in title
c.
i. ink was,not given in title
\\
Event Date 0 (30)
a.
Date not included or was incorrect.
I b.
Discovery date given instead of event
!
date.
LER Number was not included or was incorrect 0(30)
Report Date 1(30)
a.
Date not included I
b.
OBSERVATION: Report date was not
within thirty days of event date (or discovery date if appropriate).
Other Facilities information in field is 1 (30)
inconsistent with text and/or abstract.
Operating Mode was not included or was 0(30)
inconsistent with text or abstract.
_ _
_ -
_ _ _ _ _ _ _, _. _. _ _ _ _. _. _. _ _. _. _
_, _ _. _ _. _ - _ _ _ _
-.-
.
,
'
.
TABLE C-3.
(continued)
Number of LERs with
'
Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)b a
Power level was not included or was 0 (30)
inconsistent with text or abstract Reporting'Reauf rements 1 (30)
a.
The reason for checking the "0THER"
reauirement was not specified in the abstract and/or text.
b.
OBSERVATION:
It would have been more
appropriate to report the event under a different paragraph.
c.
OBSERVATION:
It would have been
appropriate to report this event under additional unchecked paragraphs.
Licensee Contact 0 (30)
a.
Field left blank b.
Position title was not included c.
Name was not included d. ' Phone number was not included.
,
\\
Coded Component Failure Information 2 (30)
a.
One or more component failure
sub-fields were left blank.
b.
Cause, system, and/or component code
is inconsistent with text.
c.
Component failure field contains data
when no Component failure occurred.
d.
Component failure occurred but entire
field left blank.
.
-.
-, -
,.n.
,,.,
.. - ----.
.n.-
-,,
a.,
- --. -... - -..
.,. - -
-. -
.
,
.
.
TABLE C-3.
(continued)
-
Number of LERs with Deficiencies and Observations Sub-paragraph Paragraph Description of Deficiencies and Observations Totals Totals (
)D a
Supplemental Report 1(30)
a.
Neither "Yes"/"No" block of the
supplemental report field was checked, b.
The block checked was inconsistent I
with the text.
Expected submission date information is 0 (30)
inconsistent with the block checked in Item (14).
..
a.
The "sub-paragraph total" is a tabulation of specific deficiencies or observations within certain reouirements. Since an LER can have more than one deficiency for certain reouirements, (e.g., an LER can be deficient in the area of both date and time information), the sub-paragraph totals do not necessarily add up to the paragraph total.
b.
The " paragraph total" is the number of LERs that have one or more reouirement def~iciencies or observations. The number in parenthesis is the
\\
number of LERs for which a certain reouirement was considered applicable.
i l
!
I i
-_.
- - -
., -
-.
_,. _. - - - - - _, -
--
.
, _.
_ _ - - -...
.
.
.
.
.
,
.
-
APPENDIX D LER COMMENT SHEETS FOR SAN ONOFRE 1, 2 AND 3
-,
o G
_
.
.
.
,.
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 1 (206)
,
-
Section Comments 1.
LER Number: 84-012-00 Scores: Text = 9.5 Abstract = 9.5 Coded Fields = 9.0 Overall = 9.4 Text 1.
50.73(b)(2)(ii)(I)--How was it finally determined Inat LLw ano saitwater cooling flow were mismatched in the heat exchangers?
2.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
3.
Acronym (s) and/or plant specific designator (s) are undefined.
4.
Inclusion of a diagram was good.
.,
Abstract 1.
50.73(b)(1)--Summary of root cause is inadeouate.
Mention the deficient procedure also, this is only
'
implied from corrective actions summary.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
\\
l
,
f I
_, -
, _
_ _. _ _ _ _ _ _ _.. _ _ _ _ _ _ _ _.. _ _ _ _. _ _. _ _ _.. _ _.. -, -. _, -........ _., _. _ _ _ _ _. _... -_
.. _.,
_
.
,'
.
.
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 1 (206)
Section Comments
-
2.
LER Number: 84-014-01 Scores: Text = 9.c Abstract = 9.6 Coded Fields = 8.5 Overall = 9.3 Text 1.
50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is inadeouate. Mode 3 should be defined (e.g., hot standby).
2.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract 1.
No comment.
Coded Fields 1.
Item (4)--Title: Root cause and link are not incluaed.
..
m
1
. _ _.. _ - _ _ _ -. _ _ _ _ _ _.. _ _ _ _ _ _ _.. _ _.... _ _ _ _. _ _ _. _.,. _.... _ -. _ _ _ _., _ _
_ _ _ _ _ _ _ _, _... _ _ _.. _.... _ -., _. _... _ _ _. _ _ _
. -.. -..
_
.
.
-
.
,.
.
.
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 1 (206)
Section Comments
'
3.
LER Number: 84-015-00 Scores: Text = 8.2 Abstract = 9.4 Coded Fields = 9.0 Overall = 8.6 Text 1.
50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is inadeauate. Mode 3 should be defined (e.g., hot standby).
2.
50.73(b)(2)(ii)(L)--Identification (e.g. manuf acturer and model no.) of the failed component (s) discussed in the text is not included.
3.
In the last paragraph, is the title of E0I S01-1.0-10
" Reactor Trip on Safety Injection" or " Reactor Trip or Safety InjeHion"?
4.
50.73(b)(4)--Discussion of corrective actions taken or planned is inadeouate. Will the operation of the
"
DC knife switches be checked more routinely in tne
-
future?
Abstract 1.
No comment.
Coded Fields 1.
Item (4)--Title: Link is not included.
.
.,
-.- - -
--- ~,-
,
-
-
.. -
.
-.~.,
-
_ - - -._
.
'
,'
.
.
,
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 1 (206)
i j
Section Comments
-
,
4.
LER Number: 85-004-00
i Scores: Text = 8.2 Abstract = 9.8 Coded Fields = 7.4 Overall = 8.6 i
Text 1.
50.73(b)(2)(ii)(A)--Include a brief description of
)
each operating mode number referred to in the text.
2.
50.73(b)(2)(ii)(C)--Date and time (fifth paragraph)
l Information for occurrences is inadeauate. When was the pump returned to serivce?
3.
50.73(b)(2)(ii)(F)--Include the EIIS codes for each
!
component referred to in the text.
.
4.
50.73(b)(2)(ii)(H)--A time estimate of the unavailability of the failed system is inadeauate.
(See text Comment 2).
l 5.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer
.
and mooel no.) of the failed component (s) discussed in the text is not included.
,
i 6.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events r,e known, the text snct:ld so state.
j 7.
A supp ! mental report appears to be reeded to
-
- y descrit,e the results of the continuing i
investigation. Without a commitment to submit a supplemental report, this LER must be considered incomplete.
Abstract 1.
No comment.
i l
Coded Fields 1.
Item (4)--Title: Root cause and link are not included.
,
2.
Item (ll)--0BSERVATION:
It appears it would have i
been appropriate to also report this event under
paragraph (s) 50.73(a)(2)(v).
i 3.
Item (14)--The block checked is inconsistent with i
information in the text (see text Comment 7).
I
!
!
!
I
=---.~.----.-n,,__,,._.n,,---,,
--,--,,-,.-,nen
,,-,-, -- n - n
~-,,---w-
- + - -
,.,,, -, - -, - -
-~~---,---~~,-w
-
. _.
__. -
_----
'
.
,
'
.
TABLE D 1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 1 (206)
!
Section Comments
~
l
5.
LER Number: 85-014-00
Scores: Text = 9.1 Abstract = 9.7 Coded Fields = 8.5 Overall = 9.2 Text 1.
50.73(b)(2)(ii)(D)--What was the cause of the pressure switch and relay failure on the steam dump control circuit?
t J
2.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer
and model no.) of the failed component (s) discussed in the text is not included.
3.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
!
Abstract 1.
50.73(b)(1)--Summary of root cause is inadeauate.
see comment 1 in text.
--
Coded Eields 1.
Item (4)--Title: Root cause is not included.
.
0
.
l
!
,
1 i
i y_----
.ym.,
.,.,_--,~-_.,--...w..
_,
--_,,..-c
---,... _.
__-_--,__.____,-__--__m,-,rm
. _ -,. _ _, -,.,.,,.. -, _...........
-
.
,
..
,
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Sect' ion Conments
'
6.
LER Number: 84-072-00 Scores: Text = 8.4 Abstract = 9.1 Coded Fields = 8.5 Overall = 8.6 Text 1.
50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is inadeouate. Mode 4 should be defined (e.g., hot shutdown).
2.
50.73(b)(3)--Discussion of the assessment of the safety conseouences and implications of the event is inadeouate.
If radiation conditions had occurred during the time the radiation monitor was in alarm defeat, could the CREACUS have been actuated manually in time to perform its safety function?
OBSERVATION: The availability of other systems or components capable of mitigating the conseouences of
"
the event should be discussed.
If no other systems or components are available, the text should so state.
.
3.
50.73(b)(4)--Discussion of corrective actions taken or planned is inadeouate. How will the various monitors be kept under continuous observation?
Abstract 1.
50.73(o)(1)--Summary of corrective actions taken or planned as a result of the event is inadeouate. The interim action of continuously observing the monitors
\\,
is not mentioned.
Coded Fields 1.
Item (4)--Title: Root cause and result are not included.
i l
l l
!
l
-. _ _ _. --, -.
.-
--
-, -
. -.. - _ _ - - _ - _ _ _ _ - _ _ - _ _ _ _ _ - -, _ - _ - - _ _ _ _
.
'
.
,
..
,
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
-
7.
LER Number: 84-079-01 Scores: Text = 8.8 Abstract = 8.8 Coded Fields = 9.0 Overall = 8.8 Text 1.
50.73(b)(2)(ii)(C)--Date information for occurrences is inadeouate. Wnen will repairs be completed?
2.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer and model no.) of the failed component (s) discussed in the text is inadeouate. Are model numbers or sizes available for the failed snubbers?
3.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract 1.
50.73(b)(1)--Summary of corrective actions taken or planned as a result of the event is inadeouate.
"
Indicate that procedures will be changed, redesign
.
will be made if necessary, and protective coverings will be used.
2.
Abstract contradicts the text. The total of
,
90 deficient snubbers contradicts the list of causes in the text and abstract. The list adds up to 89.
Coded Fields 1.
Item (4)--The title should at least indicate some of
\\
the major root. causes.
i
.
,, -,,,
-. -
... -. -. _. - - _.. - - - - - - -..
-
--
_
.
,-
.
.
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ONOFRE 2 (361)
Section Comments
-
8.
LER Number: 85-008-00 Scores: Text = 7.9 Abstract = 7.7 Coded Fields = 8.5 Overall = 7.9 Text 1.
50.73(b)(2)(ii)(D)--What was the cause of the drain valves failing?
2.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer and model no.) of the failed component (s) discussed in the text is not included.
3.
50.73(b)(4)--Discussion of corrective actions taken or planned is inadeouate.
A discussion of actions reouired to reduce the probability of recurrence (i.e, correction of the root cause) is not included or is inadeauate.
.,
Abstract 1.
50.73(b)(1)--Summary of root cause is inadeouate.
See text comment No. 1.
.
2.
50.73(b)(1)--Summary of corrective actions taken or planned as a result of the event is inadeouate. What actions are planned to prevent recurrence of this event?
' 3.
OBSERVATION: The abstract contains information not
\\
included in the text. The abstract is intended to be a summary of the text; therefore, the text should discuss all information summarized in the abstract.
Coded Fields 1.
Item (4)--Title: Root cause and link are not included.
.
.-
.
- -.
. -
-.. - -
,
_ _ _ _ - - - _ - -
. _ _ _ _ _ _ _
_ _ - _ -.
_ _.
.
-
.
,
'
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
-
9.
LER Number: 85-011-00 Scores: Text = 9.1 Abstract = 9.9 Coded Fields = 8.5 Overall = 9.2 Text
50.73(b)(2)(ii)(A)--Mode 6 should be defined (e.g.,
refueling).
2.
50.73(b)(2)(ii)(J)(2)--Discussion of personnel error is inadeouate.
50.73(b)(2)(ii)(J)(2)(iv)--Discussion of the type of personnel involved (i.e., contractor personnel, utility licensed operator, utility nonlicensed operator, other utility personnel) is not included.
3.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
..
Abstrac,t 1.
No comment.
Coded Fields 1.
Item (4)--Title: Root cause and link (maintenance activities) are not included.
.
i i
I i
+
-
-
.
-. -
-
- _ _
..
. _ - -
.
. - - -.
_ _ -
..-
_
.
.
.
,
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
"
10. LER Number: 85-018-00 Scores: Text = 8.6 Abstract = 9.4 Coded Fields = 9.7 Overall = 8.9 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the requirements of a text and still be less tnan 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(J)(2)(iv)--Discussion of the type of personnel involved (i.e., contractor personnel, utility licensed operator, utility nonlicensed operator, other utility personnel) is not included.
3.
50.73(b)(3)--Discussion of the assessment of the safety consecuences and implications of the event is
inadeauate.
OBSERVATION: The conseauences of the event had it
.
occurred under more severe conditions should be discussed. If the event occurred under what are considered the most severe conditions, the text should so state.
4.
50.73(b)(5)--Information concerning previous similar
events is not included.
If no previous similar i
events are known, the text should so state.
Abstract 1.
No comment.
Coded Fields 1.
No comment.
,
-, - - - - - - - - - - -
_
-
-.-,.-__.v-
,-------.--.__,y_
-.--__-__-_y
-,
,
-. -.. -,,,,..
- - - - - - - -
_ _ -,,. -.,. -
-
-
.
.
.
,.
..
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
'
Section Comments 11. LER Number: 85-021-00 Scores: Text = 7.1 Abstract = 8.1 Coded Fields = 8.5 Overall = 7.6 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is inadeouate. Mode 5 should be defined.
3.
50.73(b)(2)(11)(0)--The root and/or intermediate cause oiscussion f or the vent valve being open is inadeauate.
,,
4.
50.73(b)(2)(ii)(J)(2)--It appears tnat personnel
-
error is involveo nn this event, but it is not discussed. Wnen the normal valve lineup on valves
'
upstream of the vent valve was performed, were personnel aware that the vent valve had been positioned to support ILRT preparations? Was there a conflict in the valve lineup procedures that were used?
\\
5.
50.73(b)(51--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract 1.
_50.73(b)(1)--Summary of root cause is inadeauate.
See text statements 3 and 4.
Coded Fields
Item (4)--Title: Root cause and link (e.g.,
personnel error during valve lineup causes--) are not
}
included.
i
I f
. - - -
- -, -
,n
--.,n--,...
-,, --,,,
- -,. - - -..
-.-~n,
,-- - -
.-
-n---,-
.----.--- -
.
.
.
.
,.
..
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
-
12. LER Number: 85-022-00 Scores: Text = 8.3 Abstract = 9.5 Coded Fields = 9.0 Overall = 8.7 50.73(b)(2)(ii)(Althe event is inadeouate.-Discussion of plant operating Text 1.
conattions Defore Mode 4 should be defined.
2.
50.73(b)(2)(11)(C)--Time information for occurrences is not incluaea. At what time was the SIS actuated?
When was it secured?
3.
50.73(b)(2)(ii)(K)--Discussion of automatic and/or manual safety system responses is inadeouate. The safety systems that " performed their function" (last paragraph) should be named.
"
4.
50.73(b)(4)--The corrective actions taken to prevent recurrence were well thought out, especially the last one (i.e., extending the actions to other procedures
-
if necessary).
5.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract
' l.
Boiler plate safety assessment conclusions are not
\\.
necessary in the abstract.
Coded Fields 1.
Item (4)--Title: Root cause and link are not includeo.
,
l
- _. _ _ _ _ _ _ _,. _ _..
. _ _, _. _ _.. _ _ _
_ _ _ _...,,,,. _. _... _,, _ _ _,. _.. _.. _. _.. _ _ _. _.. _ _. _. _ _ _. _
.. _ _ _ _, _ _.. _. _
,
.
.
.
'
..
TABLE D 1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
.
Section comments
'
13. LER Number: 85-024-00 Scores: Text = 7.6 Abstract = 8.9 Coded Fields = 9.3 Overall = 8.2 Text 1.
50.73(b)(2)(ii)(A)--Include a brief description of the operating mode number.
2.
50.73(b)(2)(ii)(K)--The text should at least list all safety systems which actuated. A general statement that all systems operated satisfactorily is insufficient.
3.
OBSERVATION: The consecuences of the event had it occurred under more severe conditions should be discussed.
If the event occurred under what are considered the most severe Conditions, the text should so state.
..
4.
50.73(b)(4)--Be more specific about what changes are
.
to be made.
5.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract 1.
OBSERVATION: The abstract contains information not included in the text. The abstract is intended to be
-
\\
a summary of the text; therefore, the text should discuss all information summarized in the abstract.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
l i
.
- - - - - - -. - - - -
,-
.--
+m..
.-e
-
- - - - - - - - -, -
-.
-, - -
- - -
7
.
_
-
.
.
.
.
..
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
'
_
14. LER Number: 85-028-00 Scores: Text = 7.4 Abstract = 8.0 Coded Fields = 9.4 Overall = 7.8 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the requirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(D)--The root and/or intermediate cause discussion for the regulator failure is not included.
'
3.
50.73(b)(2)(ii)(K)--Discussion of automatic and/or
'
manual safety system responses is inadeouate. What essential control and safety systems functioned
during and after the trip?
4.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer
-
and model no.) of the failed component (s) discussed in the text is not included.
5.
50.73(b)(5)--Information concerning orevious similar events is not included.
If no previous similar events are known, the text should so state.
\\
Abstract 1.
50.73(b)(1)--Summary of the root cause of the regulator failure is not included.
l Coded Fields 1.
Item (4)--Title: Root cause is not included.
-_
.
, _. _ _ _ _ _ _ _
._-_- __, _.
_
__
_
. _ _. _.. _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _.. _ _. _
.
.
.
.
'
.
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
'
15. LER Number: 85-031-00 Scores: Text = 7.2 Abstract = 9.1 Coded Fields = 9.5 Overall = 8.0 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were e text.
2.
50.73(b)(2)(ii)(C)--Date and time information for occurrences is inadeouate. At what time was the plant considered to be in a safe and stable condition after the transient? When was the unit returned to service?
3.
50.73(b)(2)(ii)(K)--Discussion of automatic and/or
manual safety system responses is inadeauate. Major plant parameters resulting from the scram should be provided. The safety systems that actuated should
.
also be listed.
4.
50.73(b)(3)--Discussion of the assessment of the safety conseauences and implications of the event is not included. Safety assessment statements (conclusions) must be accompanied by a discussion of
~
how such conclusions were reached.
5.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar
,
events are known, the text should so state.
6.
How many rods are in Subgroup 67 l
Abstract 1.
Boiler plate safety assessment conclusions are not necessary in the abstract.-
Coded Fields 1.
Item (4)--Title: Root cause is not included.
- - _
-
, _
- - - -
-_.
._.
. _ -
,. _ -, _ -. - - -.
- - - _ - - - -
__
. - -
.
-
.
.
.
..
TABLE 0-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
~
16. LER Number: 85-035-00 Scores: Text = 8.3 Abstract = 9.8 Coded Fields = 9.0 Overall = 8.8 Text 1.
50.73(b)(3)--Discussion of the assessment of the safety conseauences and implications of the event is inadeauate.
OBSERVATION: The availability of other systems or components capable of mitigating the conseauences of the event should be discussed.
If no other systems or components are available, the text should so state.
OBSERVATION: The conseauences of the event had it occurred under more severe conditions should be discussed.
If the event occurred unoer what are considered the most severe conditions, the text should so state.
"
-
2.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract 1.
No comment.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
,
\\
.
.
.
,.
.
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
'
Section Comments 17. LER Number: 85-040-00 Scores: Text = 8.8 Abstract = 9.7 Coded Fields = 10.0 Overall = 9.2 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is inadeauate. Mode 5 should be defined.
Abstract 1.
No comment.
Coded Fields 1.
No comment.
.
i
- _ _ _..__
.- _ _ - _-
- - _ _ _ _, _ _ _ - - _, - _ - - - - _ - -
- - - -
_
__
.
.
,
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
'
18. LER Number: 85-044-00 Scores: Text = 5.9 Abstract = 8.8 Coded Fields = 9.3 Overall = 7.1 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the requirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(K)--Discussion of automatic and/or manual safety system responses is inadeauate. Why did HPSI pump 2P-018 start or was it started for testing? A list of "all systems", referred to in the last sentence, should be provided.
3.
50.73(b)(3)--Discussion of the assessment of the sarety consecuences and implications of the event is
"
not included.
.
4.
50.73(b)(4)--Discussion of corrective actions taken or planned is inadequate.
Is anything planned to prevent recurrence during the time long term corrective actions are being investigated?
<
5.
50.73(b)(5)--Information concerning previous similar
'
events is inadeouate. What type of event was S
reported in LER 84-002?
6.
A logical transition does not exist between all ideas. Some ideas are not presented clearly (hard to follow). The use of abstracts with no text should be limited to extremely simple events.
Abstract 1.
50.73(b)(1)--Summary of system responses is inadeouate. See text comment No. 2.
2.
50.73(b)(1)--Summary of corrective actions taken or i
planned as a result of the event is inadeauate. See text comment No. 4.
t Cooed Fields 1.
Item (4)--Title: Root cause is not included.
l
!
i I
!
-
.-.
_ -. -.
_. -.., -. - -,
... - - -. - - _ - _
. _. -... - _ _. - - - - - -.. _..., _ _.. _. - - - -, _ _ _ -.. - -
-, - - - _ _ _ _
_
.
_
-_.
.
.
.
,
'
.
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
-
19. LER Number: 85-046-01 Scores: Text = 8.0 Abstract = 9.3 Coded Fields = 9.5 Overall = 8.5 Text 1.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer and model no.) of the f ailed component (s) discussed in the text is not included.
2.
50.73(b)(4)--It would be helpful to know the trecuency of brush replacement after refinishing the slip rings to indicate to a reader whether or not the problem was fixed. From the text, it is not apparent that the brush wear problem was corrected.
'
4.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstrect 1.
No comment.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
.
r
,
. _ _ _
__
,, _, _,
,.. _.
_
_,.,. _.. _. _..
-.
.
-, _..,
.
b
.
..
TABLE 0-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
Section Comments
"
20. LER Number: 85-Of2-00 Scores: Text = 6.5 Abstract = 7.9 Coded Fields = 10.0 Overall = 7.3 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reouirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(11)(A)--Discussion of plant operating conditions before the event is inadeouate. Mode 6 for Unit 3 is undefined.
3.
50.73(b)(2)(ii)(D)--The root and/or intermediate cause discussion f or the spurious actuation is inadeouate. Were any investigations performed as to wny the actuation occurred below the setpoints?
"
4.
50.73(b)(4)--Discussion of corrective actions taken or planned is not included. Prior corrective actions that have been implemented reference LER 85-10. Each LER should stand alone. What corrective actions are being planned to prevent recurrence of this event?
Abstract
,
1.
50.73(b)(1)--Summary of the cause of the-spurious actuations is inadecuate.
See text Statement 2.
\\
2.
50.73(b)(1)--Summary of corrective actions taken or planned as a result of the event.is not included.
a 3.
Abstract should nct contain a reference.
Coded Fields 1.
No comment.
...
_-
.
___ - -
- - _ _.
-
--
.
i
.
,
'
,.
...
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 2 (361)
'
Section Comments 21. LER Number: 85-053-00
,
j Scores: Text = 9.0 Abstract = 9.9 Coded Fields = 9.0 Overall = 9.3
Text 1.
50.73(b)(3)--Discussion of the assessment of the safety consecuences and implications of tne event is
,
inadequate. How was it determined that "the release
remained well below Technical Specification limits"?
2.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
I 3.
Some ideas are not presented clearly (hard to follow).
1.
No comment.
Coded Fidids 1.
Item (4)--Title: Root cause and result (technical specification violation) are not included.
I
~
.
t l
~.
$
,, =. - - - -
-, -.,,
,,.,. - - - - -.,,,,,,. - - -,,. - _... -. - - -. - -. - - - -,.. - - -. -. - -, -
- - - -.
.-.
--
.
h
- l a e TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ONOFRE 2 (361)
Section Comments
'-
22. LER Number: 85-054-00 Scores: Text = 7.9 Abstract = 9.4 Coded Fields = 9.2 Overall = 8.5 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 characters. Tne following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(C)--When was Revision 4 completed?
3.
50.73(b)(2)(ii)(J)(2)(iv)--Discussion of the type of personnel involved (i.e., contractor personnel, utility licensed operator, utility nonlicensed operator, other utility personnel) is not included.
Who was responsible for the omission?
.,
4.
50.73(b)(3)--Discussion of tne assessment of the
-
safety consecuences and implications of the event is inadeauate. The safety assessment should consider the consecuences had the breakers actually been found faulty.
5.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar
-
events are known, the text should so state.
Abstract 1.
The abstract contains greater than 1400 characters.
Coaed Fields 1.
Item (4)--Title: Root cause is not included.
_ _
.
.
.
..
'
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ONOFRE 3 (362)
Section Comments
'
23. LER Number: 84-040-00 Scores: Text = 7.7 Abstract = 9.2 Coded Fields = 8.5 Overall = 8.3 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(K)--Discussion of automatic and/or manual safety system responses is inadeauate. What safety systems were verified for proper operation and what were the major plant responses?
3.
50.73(b)(2)(ii)(L)--Identification (e.g. manuf acturer and model no.) of the failed component (s) discussed in the text is not included.
--
.
4.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
,
Abstract 1.
No comment.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
'
,
T 2.
Item (13)--Component failure occurred but entire field is blank.
.
!
._
O s
.
'
,,'
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 3 (362)
Section__
Comments
~
24. LER Number: 85-004-00 Scores: Text = 7.0 Abstract = 8.8 Coded Fields = 9.5 Overall = 7.8 Text 1.
~50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is inadeauate. Mode 5 should be defined.
2.
50.73(b)(2)(ii)(I)--Discussion of the method of aiscovery or tne celinauent sample is not included.
3.
50.73(b)(3)--Discussion of the assessment of the safety conseauences and implications of the event is not included.
4.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar
"
events are known, the text should so state.
5.
A logical transition does not exist between all ideas. Some ideas are not presented clearly (hard to follow). What is the reason for pointing out that the RCS sample (in first paragraph) was not reouired by the Technical Specifications? Was the 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> sample reauired because of the high I-131 activity?
Abstract 1.
Abstract describes the text as opposed to summarizing
$
it.
Coded Fields 1.
Item (4)--Title: Root cause of the delinauent sample is not included.
.
!
!
-
-
-
._.
_
-
.
R
.
.
,.
s TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ONOFRE 3 (362)
'
Section Comments 25. LER Number: 85-006-00 Scores: Text = 8.6 Abstract = 8.9 Coded Fields = 8.5 Overall = 8.7 Text 1.
50.73(b)(2)(ii)(A)--Include a brief description of the operating mode number.
2.
50.73(b)(2)(ii)(D)--What caused the valve to stick?
3.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer and model no.) of the failed component (s) discussed in the text is not included.
4.
50.73(b)(4)--Was any effort made to free the sticky operator and to prevent it from sticking in the future?
Abstract'
l.
OBSERVATION: The abstract contains information not included in the text. The abstract is intended to be
.
a summary of the text; therefore, the text should discuss all information summarized in the abstract.
Unit 2 was not mentioned in the text.
Coded Fields 1.
Item (4)--Title: Root cause and link are not included.
- 2.
Item (8)--Information in field is inconsistent with
\\
text and/or abstrac.
.
.
'
,. -
.
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 3 (362)
Section Comment-
--
26. LER Number: 85-008-00 Scores: Text = 9.1 Abstract = 8.1 Coded Fields = 9.3 Overall = 8.8 Text 1.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
2.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer ano moael no.) of the failed component (s) discussed in the text is inadeouate. The failed component should be identified such that others can check for similar problems at their facility. From tne information provided in the text, what probably
>
should be identified is the manufacturer and model number of the valve which has the feedback mechanism attached with a carbon steel cap screw.
.,
Abstract 1.
50.73(b)(l)--Summary of corrective actions taken or
-
planned as a result of the event is inadeouate. A summary of corrective actions to prevent recurrence should be included.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
.
.
l l
l
., - _ _ _ _ _ _. -.-
,--,
,
"
.
s
-
.
'
....
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 3 (362)
-
Section Comments
'
27. LER Number: 85-017-01 Scores: Text = 9.2 Abstract = 9.7 Coded Fields = 9.5 Overall = 9.4 Text 1.
50.73(b)(2)(ii)(L)--Identification (e.g. manufacturer ana model no.) of the failed component (s) discussed in the text is inadeauate. Model number of inoperable snubbers should be provided.
2.
The use of a " revision bar" is good.
Abstract 1.
No comment.
Coded Fields 1.
Item (4)--Title: Link (post-maintenance check) is not included.
..
.
e
l l
,
l
.
l t
- --
w-
-
-
-
e ve,-
>-,
c
,r--m-
- - - - - - -, -,. - - - - - - - - - - - - - - - - - - - - - -. - - - -. - -. - - -. -,,, - - - -.
,4----
.
- .,'... a'
,
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 3 (362)
Section Comments
'
28. LER Number: 85-019-01 Scores: Text = 6.8 Abstract = 8.1 Coded Fields = 8.5 Overall = 7.3 Text 1.
Submittal of an LER without a text is acceptable;
~
however, the abstract must then meet all the requirements of a text and still be less than 1400 cnaracters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(A)--Include operating conditions before each actuation.
3.
50.73(b)(2)(ii)(D)--The LER text is supposed to stand alone (i.e., contain all pertinent data about the event). While the cover letter indicates that the most probable cause was ground current, the text only
"
implies, from the corrective actions, that the grounds might be the problem.
.
4.
50.73(b)(4)--As for the root cause (text Comment 3),
the cover letter discussion of corrective actions is more complete than the text. Be sure that the text includes all pertinent data.
, 5.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar S
events are known, the text should so state.
6.
The fact that LER 85-019-00 indicated the need for a supplemental report to discuss the results of the engineering evaluation was good.
Abstract 1.
No comment.
Coded Fields 1.
Item (4)--Title: Root cause is not included.
2.
Item (7)--The report date for LER 85-019-01 is okay, but it could not be determined if the report date for LER 85-019-00 was okay since the day field was left blank.
.
-p
,, -
wr m
e
+n
-
-
..
o
,0..
...
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 3 (362)
~
Section Comments 29. LER Number: 85-027-00 Scores: Text = 8.7 Abstract = 9.6 Coded Fields = 9.0 Overall = 9.0 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(A)--Discussion of plant operating conditions before the event is not included.
3.
50.73(b)(5)--Information concerning previous similar events is inadeauate. Since a previously planned modification is being implemented as a corrective action, it appears that this event has occurred
"
previously.
Abstract 1.
No comment.
Coaed Fields 1.
Item (4)--Title: Root cause is not included.
.
j
-
.
+f.../.,.
..
TABLE D-1.
SPECIFIC LER COMMENTS FOR SAN ON0FRE 3 (362)
.
Section Comments 30. LER Number: 85-028-00 Scores: Text = 8.3 Abstract = 9.9 Coded Fields = 8.5 Overall = 8.8 Text 1.
Submittal of an LER without a text is acceptable; however, the abstract must then meet all the reauirements of a text and still be less than 1400 Characters. The following comments apply to the abstract that was evaluated as if it were a text.
2.
50.73(b)(2)(ii)(C)--A date should have been provided in the second paragraph, the next to last sentence.
3.
50.73(b)(3)--Discussion of the assessment of the safety conseauences and implications of the event is inadeouate.
It is not clear why it is alright to place Monitor 3RT-7822 in alarm defeat when the
"
readings are valid.
If personnel are in the area,
_
the source of activity should not matter.
4.
50.73(b)(5)--Information concerning previous similar events is not included.
If no previous similar events are known, the text should so state.
Abstract l.
No comment.
_
T Coded Fields 1.
Item (4)--Title: Root cause and link (fuel transfer tube) are not included.
f
. - _
-
_
_
_
. _ _ _ _ _. _ _ _ _