Exe k¢ n W Exelon Generation Company, LLC www.exeloncorp.com Nuclear Byron Station 4450 North German Church Road Byron, IL 61010-9794 January 12, 2004 LTR: BYRON 2004-0004 FILE: 3.11.0321 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Byron Station, Unit 1 Facility Operating License No. NPF-37 NRC Docket No. STN 50-454

SUBJECT:

Byron Station Unit 1 90-Day Inservice Inspection Report for Interval 2, Period 3, Outage 1 (81 R12)

The subject 90-day Inservice Inspection Report for the Byron Station Unit 1, Refueling Outage Twelve (i.e., B1R12) is being submitted pursuant to the requirements of Article IWA-6000, "Records and Reports" of Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, 1989 Edition. The report covers the inservice inspections conducted prior to and during the Unit 1 Fall 2003 refueling outage.

If there are any questions regarding this matter, please contact W. Grundmann, Regulatory Assurance Manager, at (815) 406-2800.

Respectfully, Stephen E. Kuczynski Site Vice President Byron Nuclear Generating Station SEK/RGM/rah

Attachment:

BlRl2 Inservice Inspection Summary Report- Fall 2003 Outage cc: Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - Byron Station d4~7 K.\BXNR_.DOCS\_.Yyrhrs\04byltrs\040004.doc

BYRON Exe k nim UNIT 1 Nuclear B1R12 Fall 2003 Outage IN¶SERVICE INSPECTION

SUMMARY

REPORT For inspection Activities from March 30, 2002 to October 14, 2003 Commerical Service Date September 16, 1985 Document Completion Date January 6, 2004 Exelon Generation Company, LLC 4300 Winfield Rd Warrenville, IL 60555 Byron Nuclear Power Station 4450 North German Church Rd.

Byron, IL 61010

BYRON UNIT 1 Exe OniM Nuclear

- I B1R12O S INSERVICE INSPECTION

SUMMARY

REPORT SECTION SECTION DESCRIPTION PAGES iCover Page 1 lii ITable of Contents 1 i1 lReport Introduction 9 9.

Welds & Components 12 Obstructed Examinations 1 2 Examination Summary Tables Pressure Tests 7 Containment Structure 1

. Component Supports .6

.___________ Snubbers 11 Welds & Components 11 Pressure Tests 9 Containment Structure I 3 Form NIS-1 . .SME Signature Page 1 ASMEFormNIS-1Component Supports 7 Signature Page 1 Snubbers 16

._______________________ Signature Page 1 1 -7 4 IASME Form NIS-2 7- Repairs / Modificationsl 66 I.

TOTAL PAGES IN REPORTl 162 l

BYRON STATION UNIT I REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT

1.0 INTRODUCTION

Inservice inspections of American Society of Mechanical Engineers (ASME) Class 1, 2, 3, CC and MC components were conducted at Byron Station Unit 1 from March 30, 2002 through October 14, 2003. The majority of these inspections were performed during the twelfth refueling outage (BlR12) from September23 through October 14, 2003. The examinations were performed in compliance with the rules and regulations of ASME Section XI, Division 1, "Rules for Inservice Inspection of Nuclear Power Plant Components,"

(applicable edition and addenda), pursuant to the requirements of 10 CFR 50.55a, "Codes and Standards." This summary report meets the requirements of ASME Code, IWA-6000 for the inspection of Class 1 and 2 components and piping. This report also includes inspection results of components for Class 3, CC, MC, and Augmented Programs. See Section 3.0 for a.

listing of referenced documents.

The Nondestructive Examination (NDE) Inservice Inspection (ISI) Program Plan for Class 1, 2, and 3 components was developed in accordance with the requirements and intent of Section XI Subsections IWA, IWB, IWC, IWD, and IWF, 1989 Edition, No Addenda, and Subsections IWA and IWE and IWL, 1998 Edition, No Addenda for Class CC and MC components. In addition to the ASME Section XI requirements of examination, certain Nuclear Regulatory Commission (NRC) augmented ISI inspections were required. The Byron Station Unit I augmented ISI examination requirements include:

a) High-energy lines in accordance with NUREG 0800, "Standard Review Plan";.

b) Class I pressure boundary for leakage at nominal operating pressure, in accordance with NRC Generic Letter 88-05, "Boric Acid Corrosion of Carbon Steel Reactor Pressure Boundary Components in PWR Plants";

c) Class 2 and 3 pressure boundary for leakage at nominal operating pressure, in accordance with NUREG 0737, "Clarification of TMI Action Plan Requirements";

d) Examination of RCP Flywheels in accordance with Regulatory Guide 1.14.

Note: Specific requests for relief were developed and submitted for the NRC's review when the code and/or augmented requirement(s) were deemed to be impractical, results in excessive hardship, or an alternative examination method is determined as more suitable for the particular component.

1.1 Identification of Examination Requirements The ISI Program contains the NDE program tables. These tables are presented in a tabular format consistent with the tables found in Subsections IWB, IWC, IWD, IWE, and IWF, and IWL-2500 of the ASME Code. The NDE tables include the corresponding code category, item number, and component/weld selection in conformance with examination requirements and intent of Subsection IWA, IWB, IWC, IWD, IWE, IWF, and IWL of Section XI of the ASME Code. Program notes, relief requests, and additional information are identified in the "remarks" column.

Page 1 of 9

BYRON STATION UNIT I REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT For Class 1 and 2 piping, the requirements of Risk Informed Inservice Inspection (RI-ISI) are followed using Table I of ASME Code Case N-578-1, and EPRI Topical Report TRI 12657 Revision B-A, "Revised Risk-Informed Inservice Inspection Procedure." This alternate.

selection and examination method was approved for use with Byron Station's Request for Relief I2R40 and was incorporated into the program plan (currently Revision 4, dated February 15, 2002). This request was granted by a Safety Evaluation (SER) dated February 5, 2002.

1.2 Identification of Exempted components ASME Class 1, 2, and 3 components, or parts of components, that are not included in the NDE tables and that are exempt from examination, as specified in Section XI Paragraphs IWB, IWC, and IWD-1200, "Components Exempt from Examination," and Table IWD-2500-1, are identified in the NDE Program Plan in conjunction with technical justification(s) for exempting the component/system. Class 1 or 2 piping welds exempted by IWB and IWC 1200 are not included in the establishment of the RI-ISI program. Previous selection and examination exemptions identified in Tables IWB and IWC 2500-1 for Examination Categories B-F, B-J, C-F-1, and C-F-2, are not allowed under the requirements of the RI-ISI program. With the adoption of RI-ISI, welds evaluated as Risk Category 6 or 7 are not required to be subject to examination.

1.3 Implementation of the ISI Program Exelon Nuclear, or its designee, visually examined ASME components utilizing the following test methods: VT-1, VT-2, and VT-3. The components examined comply with the ISI Program Schedule, Byron Station Technical Specifications, and/or comply with the ASME Section XI Repair/Replacement Program.

Certified personnel performed and evaluated visual examinations (i.e., VT-I, VT-2, and VT-

3) of Class 1, 2, and 3 components and supports. Exelon Nuclear personnel certification procedures comply with the requirements of ANSI/ASNT CP-189, 1991 Edition and ASNT SNT-TC-1A, 1984 Edition.

Certified personnel performed and evaluated all NDE. Personnel were certified to the requirements of the ASNT SNT-TC-IA, 1984 Edition. Additionally, ultrasonic examiners were certified in accordance with ANSIIASNT CP-189, 1991 Revision. The NDE procedures were developed and certified in conformance with ASME Section V and XI, 1989 Edition, and the 1995 Edition with the 1996 Addenda as applicable.

All ISI NDE, including evaluation of flaw indications, were performed in accordance with the requirements stipulated under Section XI, Subarticle IWA-2200 "Examination Methods."

For components incorporated into the RI-ISI program, the guidance for the examination volume for a given degradation mechanism is provided by the EPRI Topical Report while the guidance for the examination method is provided by Code Case N-578-1.

Page 2 of 9

BYRON STATION UNIT 1 REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT All ISI NDE, including evaluation of flaw indications, were performed in accordance with the requirements stipulated under Section XI, Subarticle IWA-2200 "Examination Methods."

1.4 Witness and Verification of Examination The inservice inspections were witnessed and/or verified by the Authorized Nuclear Inservice Inspectors (ANII), J. Hendricks and R. Ward. These inspectors are associated with Hartford Steam Boiler Inspection and Insurance Company of Connecticut, Chicago Branch, at 2443 Warrenville Rd., Suite 500, Lisle, Illinois 60532.

Page 3 of 9

BYRON STATION UNIT I REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT 2.0 EXAMINATION SUMMARIES The following section contains summaries of examinations performed during the refueling outage. Refer to each summary table for additional information or for specific tests and examinations conducted during this term.

2.1 Welds & Components Summary PIPING AND PUMPS VESSEL WELDS COMPONENT I SYSTEM PRESSURE AUGMENTED e E Q BASIC DESCRIPTION RETAINING X HELB- - n

.m (A BOLTING IZ >

WELDS ECCS- M Z STUDS A Z FLYW.HEELS co CI20 EXAMINATION METHOD SUR VOL VT SUR SUR VOL VT SUR VOL SUR VOL VOL SUR VOL SUR VOL VT VT SURFACE. VOLUMETRIC. VISUAL __ _

CS-Containment Spray CV-Chem. & Vol. Control 7 14 1 1 FW-Feedwater 1 9 MS-Main Steam _ 1 PZR-Pressurizer Vessel _ 1 RC-Reactor Coolant 3 43 1 4 RH-Res. Heat Removal 1 2 1 2 RPV-RX Pressure Vessel 2 1 RY-Pressurizer Piping 3 2 3 SD-St. Gen. Blowdown 1 SG-Steam Generators 2 SI-Safety Injection 14 9 1 3 _4 SX-Essential Ser. Water EXAM TYPE TOTAL 2 29 68 5 1 14 3_ 2 _ 2 1 112 COMPONENT/EXAM 122 5 _ 2 TOTAL 1 5 1 OUTAGE EXAM TOTAL 139

-HELB: High Energy Line Break examinations per NUREL U00UU.

Page 4 of 9

BYRON STATION UNIT I REFUELING OUTAGE 12

.INSERVICE INSPECTION REPORT 2.2 System Pressure Test Summary EXAMINATION AREA LEAK FUNCTIONAL INSERVICE PNEUMATIC Class 1 Vessel Pressure Retaining Boundary 6 Class 1 Piping, Pressure Retaining Boundary 1 Class 1 Pumps, Pressure Retaining Boundary 4 Class 1 Valves, Pressure Retaining Boundary I Class 2 Vessel Pressure Retaining Boundary 4 10 Class 2 Piping, Pressure Retaining Boundary 22 20 13 Class 2 Pumps, Pressure Retaining Boundary 6 3 Class 2 Valves, Pressure Retaining Boundary 22 20 13 TOTALS 12. 54 53 26 2.3 Containment Examination Summary EXAMINATION ITEM* I AREA COMMENTS E1.1 1 Containment Liner 100% of Accessible Surfaces Examined E1.30 Moisture Barrier 100% Examined

  • Examination item number from Table IWE 2500-1 Page 5 of 9

BYRON STATION UNIT I REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT 2.4 Component Support Examination Summary SYSTEM EXAMINED CLASS VT-3

.1 8 CV-Chemical & Volume Control 2 2 RC-Reactor Coolant 1 5 RH-Residual Heat Removal

2. 4 RY- Pressurizer Surge and Piping 31 SI-Safety Injection 2 9 TOTALS 50 2.5 Component Snubber Test Summary SYSTEM EXAMINED VT-3 EXAMINED FUNCTIONAL TEST CC-Component Cooling . 5 . 1 CV-Chemical & Volume Control 31 3 MS-Main Steam 12 2 RC-Reactor Coolant 53 8 RH-Residual Heat Removal 5 RY-Pressurizer Surge and Piping 21 2 SD-Steam Generator Blowdown 1 Safety Injection 17 1 TOTALS 145 17 Page 6 of 9

BYRON STATION UNIT 1 REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT 2.6 Repair/Replacement Summary A total of 56 ASME Form NIS-2, "Owners Report for Repairs or Replacements," were filed during Byron Station Unit I Cycle 12. The following is a system summary of NIS-2's generated:

SYSTEM TOTAL NIS-2 FORMS NUMBER OF PAGES AB-Boric Acid 1 1 CC-Component Cooling 4 4 CV-Chemical Volume Control 6 6 DG-Diesel Generator 5 5 DO-Diesel Fuel Oil 2 2 MS-Main Steam 8 16 RC-Reactor Coolant 2 2 RH-Residual Heat Removal 2 2 RY-Pressurizer and Pressurizer Piping 3 . . 4 SA-Service Air 1 1 SD-Steam Generator Blowdown 2 . 2 SX-Essential Service Water 14 . 14 VQ-Containment Ventilation 2 2 WE-Auxiliary Building Equipment Drains 2 3 Spare Components 2 . 2 TOTAL 56 66 Page 7 of 9

BYRON STATION UNIT I REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT 3.0 REFERENCED DOCUMENTS 3.1 Code of Federal Regulations, Title 10 "Energy" Part 50, "Domestic Licensing of Production and Utilization Facilities" 50.55a, "Codes and Standards" 3.2 American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section V, "Nondestructive Examination," 1989 Edition, No Addenda,Section V, "Nondestructive Examination," 1995 Edition, with the 1996 Addenda,Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," 1989 Edition, No Addenda, Division 1 Rules for Inspection and Testing of Components of Light-Water Cooled Plants Subsection IWA: "General Requirements" Article IWA-2000: "Examination and Inspection" Article IWA4000: "Repair Procedures" Article IWA-6000: "Records and Reports" Article IWA-7000: "Replacement" Subsection IWB: "Requirements for Class 1 Components of Light-Water Cooled Plants" Article IWB-1000: "Scope and Responsibility" Article IWB-2000: "Examination and Inspection" Table IWB-2500-1: "Examination Categories" Subsection IWC: "Requirements for Class 2 Components of Light-Water Cooled Plants" Article IWC-I000: "Scope and Responsibility" Article IWC-2000: "Examination and Inspection" Table IWC-2500-1: "Examination Categories" Subsection IWD: "Requirements for Class 3 Components of Light-Water Cooled Plants" Article IWD-l 000: "Scope and Responsibility".

Article IWD-2000: "Examination and Inspection" Table IWD-2500-1: "Test and Examination Categories" Subsection IWF: "Requirements for Class 1, 2, 3, and MC Component Supports of Light-Water Cooled Plants" Article IWF-2000: "Examination and Inspection" Table IWF-2500-1: "Examination Categories" Mandatory Appendices Appendix II: "Owner's Report for Inservice Inspections" (Forms NIS-1 and NIS-2)

Page 8 of 9

BYRON STATION UNIT 1 REFUELING OUTAGE 12 INSERVICE INSPECTION REPORT 3.2 ASME Boiler and Pressure Vessel Code (cont'd)

Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components", 1998 Edition, No Addenda, Division 1 Rules for Inspection and Testing of Components of Light-Water Cooled Plants Subsection IWE, "Requirements for Class MC and Metallic Liners of Class CC Components of Light-Water Cooled Plants" Article IWE-2000, "Examination and Inspection" Table IWE-2500-1, "Examination Categories" Subsection IWL, "Requirements for Class CC Concrete Components of Light-Water Cooled Plants" Article IWL-2000 Examination and Inspection Table IWL-2500-1, "Examination Categories" Cases of ASME Boiler and Pressure Vessel Code Case N-578-1 "Risk-Informed Requirements for Class 1, 2, or 3 Piping, Method B,Section XI, Division 1" 3.3 American National Standards Institute / American Society for Nondestructive Testing ANSI/ASNT CP-189, 1991 Edition, "Standard for Qualification and Certification of Nondestructive Testing Personnel" 3.4 American Society for Nondestructive Testing ASNT Recommended Practice No. SNT-TC-1A, 1984 Edition, "Personnel Qualification and Certification in Nondestructive Testing" 3.5 Miscellaneous NRC Documents NUREG-0800, Section 3.6.1, "Plant Design for Protection Against Postulated Piping Failures in Fluid Systems Outside Containment" Approval of Relief Request I2R-40 for Application of Risk-Informed Inservice Inspection Program as an Alternative to the ASME Boiler and Pressure Vessel Code Section XI Requirements for Class 1 and.2 Piping Welds for Byron Station, Units 1 and 2 (TAO NOS.

MB0567 AND MB0568)

Safety Evaluation by the Office of Nuclear Reactor Regulation, Risk Informed Inservice Inspection Program Relief Request, Exelon Generation Company, Byron Station Units I and 2, Docket Nos. STN 50-454 and STN 50-455 Information Notice 79-19, "Pipe Cracks in Stagnant Borated Water Systems at PWR Plants" Page 9 of 9

Exelon Byron Unit 1 Welds / Components BlR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Chemical Volume Control (CV) Second Third

      • C7 O CMPNETINE COMPOETWL .EXAMUTYPE, - OE N MBER ,, A OD RCODE-Y E SOMETEC VIDENTIFICATION - NUBER SU _VOL I __v;________-'_-_,___3_______:_.12-110 C-C C3.30 1RHP-1 ICV-01-PA CVPE-3 X _ X No Record Ind. Ref: 12R-06.12-023 R-A 4 RR1.20 1CV-1 8 1CV05CA-6" C06 X No Record Ind. Initial data.12-024 R-A4 R1.20 1CV-18 ICVO5CA-6" C07 X No Record Ind. Initial data.12-151 R-A 4 R1.20 1CV-19 ICV05CB-6" C06 X No Recordable Indications.12-149 R-A4 R1.20 I CV-18 ICV98BB-8" C02 X No Recordable Indications.12-150 R-A 4 R1.20 1CV-18 ICV98C-8" C03 X No Recordable Indications.12-147 R-A4 R1.20 1CV-17 ICV99A-8" C02 X No Record Ind. Initial data.12-148 R-A 4 R1.20 I CV-17 1CV99A-8" C03 X No Record Ind. Initial data.12-070 R-A 5 R1.11 IRC-36 ICVA3AA-2" W-06 l X No Recordable Indications.12-071 R-A 5 RI.11 1RC-36 ICVA3AA-2" W-07 _ X No Recordable Indications.12-012 R-A 5 R1.11 1CV-05 1CVA3B-2" W-74 l X No Recordable Indications.12-013 R-A 5 RI.11 1CV-05 1CVA3B-2" W-75 X No Recordable Indications.12-014 R-A 5 R1.11 ICV-05 1CVA3B-2" W-76 X No Recordable Indications.12-015 R-A 5 R1.11 ICV-05 1CVA3B-2" W-77 = X No Recordable Indications.12-016 R-A5 R1.11 ICV-05 1CVA3B-2" W-84 X No Recordable Indications.12-017 R-A5 R1.11 ICV-05 1CVA3B-2' W-85 X No Recordable Indications.12-018 R-A 5 R1.11 ICV-08 1CVA5M-2" W-04 _ X No Recordable Indications.12-019 R-A 5 R1.11 I1 CV-08 1CVA5AA-2" W-05 X No Recordable Indications.12-020 R-A 5 R1.11 I1CV-11 1CVA6AA-2" W-04 - X No Recordable Indications.12-021 R-A 5 R1.11 I1 CV-11 I1CVA6AA-2" W-05 X No Recordable Indications.12-086 R-A 5 R1.1 1RC-37 1CVA7AA-2" W-08 X No Recordable Indications.12-087 R-A 5 R1.1 1RC-37 ICVA7AA-2" W-09 X No Recordable Indications.

I.I II_ I I III Page 1 of 12

Exelon Byron Unit 1 Welds / Components BlR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Feedwater (FW). Second Third NUMBER T-OTEODERT -E T :E T +- ENTINEl COMPONENT I WELD - E YPE..

NUMBER CATEGORY -OENIFICT)O.I . NUaER SUR VOL IVIS ________________

12-153 R-A 3 R1.11 I1FW-01 IFW03DD-16" C01 X I.D. Geometry 360° Intermittent.12-175 AUG HELB I FW-12 I FW81BD-6" C03 X _ No Recordable Indications.12-176 AUG HELB 1FW-12 1FW81 BD-6" C04 X No Recordable Indications.12-177 AUG HELB 1FW-12 1FW81 BD-6" C05 X lNo Recordable Indications.12-178 AUG HELB 1FW-12 1FW81 BD-6" C06 X No Recordable Indications.12-179 AUG HELB IFW-12 IFW87CD-6" C06A X _ No Recordable Indications.12-180 AUG HELB IFW-12 IFW87CD-6" C02A X No Recordable Indications.12-181 AUG HELB IFW-12

.FW87CD-6" C03A X No Recordable Indications.12-182 AUG HELB IFW-12 1FW87CD-6" C04A X INo Recordable Indications.12-183 AUG HELB IFW-12 1FW87CD-6" C05A X No Recordable Indications.

- 111_____I-1I- -II_____

Page 2 of 12

Exelon Byron Unit 1 Welds / Components BlR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Main Steam (MS) Second Third CODE ITEM C COMPONENTILINE CO-MPOET IWELID .EXAMTYPE OTES NUMBER~ CATEGORY IMERC DNTICATION. -: ',"NUMBER SUR VOL VIS ______________

12-195 AUG HELB lMS-04 lMS01BA-30%" C01 X = No Recordable Indications.12-203 C-C C3.20 I MS-04 1MS07BA-28" E-2 X No Record Ind. Configuration

_______ ________ _ _ ._ _ lim its access.

=LLII I = ==-____

Page 3 of 12

Exelon Byron Unit 1 BlR12 Welds / Components OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Pressurizer Surge (RY) Second Third OBS COD IEMISOETI COMPONENTILINE COMPNENT I WELD EXAM TYPENOE NUMBER CATEGORYICATION -NUMBER , SUR VOL VIS -________-_F'_______

12-067 B-G-2 B7.50 1RC-32 1RY03BA-6" FLG 1-12 X No Recordable Indications.12-030 R-A2 RI.11 IRC-05 1RY11A-14" J07 X No Recordable Indications.12-031 R-A2 R1.1l1 1RC-05 1RY11A-14" J08 X No Recordable Indications.12-032 R-A 2 R1.11 1 RC-05 1RY11A-14" J09 X No Recordable Indications.12-010 R-A.2 RI.11 CV-02 IRYI8A-2" W-05A X No Recordable Indications.12-011 R-A 2 R1.11 I1 CV-02 IRY18A-2" W-100 _ X No Recordable Indications.12-139 B-G-2 B7.50 ISI-23 1RY76A-2" FLG 1-8 _ X No Recordable Indications.

B-G-2 B7.50 1RC-32 1RY03BC-6" FLG 1-12 X No Record Ind. Baseline exam of

____________________ ________ _ _l_____ _replacem ent.

Page 4 of 12

Exelon Byron Unit 1 Welds / Components BlR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Pressurizer Vessel (PZR) Seconid Third OB NUMBER

,01D~' CODE ITM A~~~~~~~~~~~IETC CATEGORY COMPONEN1ILINEj~

IET)FCTON,-

COMPONEt4TIWELD NUMBER' 75 XA TYPE! P  ;

SURI VOL I VIS________________

VOTS.'12-029 B-K B10.10 1PZR-1 1RY-01-S PSL-01 X = X No Record Ind. Ref. 12R-21.

Page 5 of 12

Exelon Byron Unit 1 Welds / Components O BIR12

.OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Reactor Coolant (RC) Second Third NW01S! l COEER l CODE rfEM DCATEGORY -l- M COMPONESURNE

.'SURC NENILNE.CMONTI COIDENTIFICATION COMPNES WELD EXAM TYPE -*

SUR VWLLNUBER T 12-049 R-A 4 R1.20 I RC-30 1RC13AA-2" W-01 X No Recordable Indications.12-050 R-A 4 R1.20 I RC-30 1RC13AA-2" W-05 X No Recordable Indications.12-051 R-A4 R1.20 IRC-30 1RC13AB-2" W-01 _ X No Recordable Indications.12-052 R-A4 R1.20 IRC-30 1RC13AB-2" W-09 - X No Recordable Indications.12-053 R-A4 R1.20 1 RC-30 1RC13AC-2" W-01 _ X No Recordable Indications.12-054 R-A 4 R1.20 1RC-30 1RC13AD-2" W X No Recordable Indications.12-072 R-A 2 R1.11 1RC-36 IRC14AA-2' W-02 - X No Recordable Indications.12-073 R-A2 R1 I 1RC-36 1RC14AA-2" W-03 X No Recordable Indications.12-074 R-A 2 RI. 1I. I RC-36 1RC14AA-2' W-03A __X No Recordable Indications.12-075 R-A2 R1.11 1RC-36 1RC14AA-2' W-03B X No Recordable Indications.12-076 R-A 2 R1.11 1RC-36 1RC14AA-2" W-03C X No Recordable Indications.12-077 R-A 2 R1.11 1 RC-36 1RC14AA-2" W-04 X No Recordable Indications.12-078 R-A 2 R1.11 1 RC-36 1RC14AA-2" W-05 ___ X No Recordable Indications.12-079 R-A 2 RI.11 1RC-36 1RC14AA-2" W-07 X No Recordable Indications.12-080 R-A 2 RI.1 IRC-36 1RC14AA-2" W-08 __ X No Recordable Indications.12-081 R-A2 R1.11 I1RC-36 1RC14AA-2" W-09 X No Recordable Indications.12-082 R-A2 RI.11 l RC-36 1RC14AA-2" W-10 X No Recordable Indications.12-083 R-A 2 R1.11 1RC-36 1RC14AA-2" W-110 X No Recordable Indications.12-084 R-A2 RI 1 1 RC-36 1RC14AA-2' W-12 X No Recordable Indications.12-085 R-A 2 RI.11 IRC-36 1RC14AA-2" W-103 X No Recordable Indications.12-055 R-A 2 RI.1I1 IRC-31 1RC14AB-2" W-07 -X No Recordable Indications.12-056 R-A 2 RI1I1 RC-31 1RC14AB-2" W-08 __ X No Recordable Indications.12-057 R-A2 RI.11 IRC-31 1RC14AB-2" W-09 ___ X No Recordable Indications.12-058 R-A 2 RI.11 lRC-31 1RC14AB-2" W-10 _ X No Recordable Indications.12-059 R-A2 RI.11 IRC-31 1RC14AB-2" W-11 _ X No Recordable Indications.12-099 R-A 2 RI.11 IRC-42 1RC14AC-2" W-08 X No Recordable Indications.12-088 R-A 2 RI .11 1RC-37 1RC14AD-2" W-08 X No Recordable Indications.12-089 R-A 2 R1.1 IRC-37 IRC14AD-2" W-09 X No Recordable Indications.12-090 R-A 2 R1.11 1RC-37 1RC14AD-2" W-10 X No Recordable Indications.12-091 R-A 2 R1.11 IIRC-37 IRC14AD-2" W-11 X No Recordable Indications.12-092 R-A 2 R1.11 1RC-37 1RC14AD-2" W-12 X No Recordable Indications.12-093 R-A 2 R1.11 I RC-37 1RC14AD-2" W-13 X No Recordable Indications.12-094 R-A 2 R1.11 IRC-41 IRC16AA-2 W-03 _ X No Recordable Indications.12-095 R-A 2 R1.11 1RC-41 IRC16A6-2" W-04 X No Recordable Indications.12-096 R-A 2 RI.11 IRC-41 IRC16AA-2" W-05 X No Recordable Indications.12-097 R-A 2 RI.11 1RC-41 IRC16AA-2" W-06 X No Recordable Indications.12-098 R-A 2 RI.11 1RC-4 1RC16AB-2" W-02 I X No Recordable Indications.12-037 R-A2 R1.11 1RC-09 1RC21AB-8" J07 X No Recordable Indications.12-038 R-A 2 RI.11 1RC-09 IRC21AB-" lJ08 X No Recordable Indications.12-040 R-A 2 R1.11 1RC-09 1RC21AB-8" J07 X _ No Recordable Indications.

I ~~~~l I 1-I--*

Page 6 of 12

Exelon Byron Unit 1 Welds / Components BlR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Reactor Coolant (cont'd) Second Third NUMBE COD TE ISOMTR COMPONENTILINE-,- COMPONENT I WELDL EXAM TYPE , . -.

NUM6ER CATEGORY IDEN FICATION ' NUMBER S-R VOL VIS E-f 12-042 B-G-2 B7.50 IRC-23 1RC22AA-1 W FLG 1-4 - _ X No Recordable Indications.12-043 R-A 4 R..20 IRC-23 IRC22AA1 W-0I X No Recordable Indications.12-044 R-A 4 R1.20 l RC-23 1RC22AA-1%" W-08 _ X No Recordable Indications.12-045 R-A 4 R1.20 IRC-23 IRC22AA-1 " W-19 X No Recordable Indications.12-046 R-A 4 R1.20 1RC-23 I RC22AM-1 A"- W-20 l X No Recordable Indications.12-047 R-A 4 R1.20 1RC-27 1RC22AA-1 /2" W-32 X No Recordable Indications.12-048 R-A 4 R1.20 I RC-27 1RC22AA-1Y2" W-33 X No Recordable Indications.12-204 B-G-2 B7.50 1RC-27 1RC22AC-1Y 2 " FLG 1-4 X Boron deposits from other leakage, bolting replaced. See RIR# 03-1-004 and BAE 2003-02 for disposition.12-041 B-G-2 B7.50 I RC-20 1RC22AD-1IW FLG 1-4 X No Recordable Indications.

B-G-2 B7.50 1RC-27 1RC22AC-1 " FLG 1-4 X No Record Ind. Baseline exam of

._____ _______ _______ _______ _____________ replacem ent.

AUG lRG1.14 IRCP-1 1RC-01-PD Flywheel X No Recordable Indications.

__ _ _ I _ _ _ _ _ I _ _ __ J 1 _ _ _ _ _ _ _ __ _ _ _ I __ _ _ _ _ _ _ __ _ __ _ _ __ _ _ _ _ _ _ _ _ _ _

I *II *I I ~~~~~~~~~~~~~I---I----I

____________ i Page 7 of 12

Exelon Byron Unit 1 Welds / Components B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Reactor Pressure Vessel (RPV) Second Third OBS:-. - COD - MTRIC COMPONENTIUE: COMPONFNTIWELD EATP CODE ITEm ISOMTI NOS NUMBER CATEGORY tDENTIFICATIONNME SUR VOL VIS_

12-225 B-O B14.10 IRPV-1 1RC-01-R H20 X No Recordable Indications.12-226 B-a B14.10 1RPV-1 IRC-01-R H21 X l No Recordable Indications.12-224 B-G-2 B7.10 1RPV-1 IRC-01-R RVLIS Clamps l X No Recordable Indications.

I I I - I __ __ __ __ __ I _ _ _ _ _ I__ I_ _ _ _ __I_ _ _ _ _ __I_ _

Page 8 of 12

Exelon Byron Unit 1 Welds / Components B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Residual Heat Removal (RH) Second Third NUMBE Co E lENT UNE COMY COMPONENT IWELO D TP _or--

NUMBER CATEGORY -~.IDENTIFICATION' i 'NUMSER' SUR VOI I ________________

12-111 C-C C3.30 1RHP-11RH-01-PA RHPE-2 lX X No Record Ind. Ref: 12R-06.12-112 AUG TRACK 1RHX-1 IRH-02-AA RHXN-01 X No Record Ind. Ref: 12R-05.12-113 AUG TRACK IRHX-1 1RH-02-AA RHXN-02 X _ No Record Ind.. Ref: 12R-05.12-105 R-A4 R1.20 1RH-05 1RH02AA-8" C02 X No Record Ind. Initial data.12-109 C-C C3.20 1RH-05 1RH02AA-8" C20 X No Recordable Indications.

Page 9 of 12

Exelon Byron Unit 1 Welds / Components BIR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Safety Injection (SI) Second .Third ISOMETRIC

,B.:D ITE CODE COMPONENTIUNE: COMPONE WELD EXA TYPE .- j ' * ' M NUMBER CATEGORY -. A'DENTFICA:TION '~ ."NME' SUR VOL 'VIS12-141 R-A4 R1.20 ISI-37 1SI02BA-6" C34 X - No Recordable Indications.12-142 R-A4 R1.20 1SI-37 1SI02BA-6" C35 X No Record Ind. Initial data.12-119 R-A 5 R1.1 I1SI-08 1SI08FA-3" J12 X _ No Record Ind. Initial data.12-120 R-A 5 R1.11 1SI-08 1SI08FA-3" J13 X No Record Ind. Initial data.12-121 R-A 5 R1.11 ISI-08 1SI08FA-3" J1 X No Record Ind. Initial data.12-122 R-A 5 R1.11 1SI-08 1SI08FA-3" J19 X No Record Ind. Initial data.12-123 R-A 5 R1.11 1SI-08 1SI08FA-3" J29 X No Record Ind. Initial data.12-124 R-A 5 R1.1 1 1SI-08 1SI08FA-3" J30 X No Record Ind. Initial data.12-125 R-A 5 RIA11. 1S-08 ISI08FA-3" J31 X No Record Id. Initial data.12-126 R-A 5 R1.11 1SI-08 ISI08FA-3" J32 X No Record Ind. Initial data.12-136 R-A 5 R1.11 1SI-20 1SI08GC-1Y2" W-01 X No Recordable Indications.12-208 B-G-2 B7.50 ISI-19 1SI08HA-2" FLG 1-8 _ X No Recordable Indications.12-128 R-A5 R1.11 1SI-19 ISI08HA-2" W-01 l X No Recordable Indications.12-129 R-A5 R1.11 1SI-19 1SI08HA-2" W-02 l X No Recordable Indications.12-130 R-A5 RI.11 1SI-19 1SI08HA-2" W-03 l X No Recordable Indications.12-137 B-G-2 B7.50 ISI-20 ISI08HD-2" FLG 1-8 .XLight rust noted, acceptable 12-131 R-A 5 RI .11 1SI-19 1SI08JA-1 1 " W-06 X No Recordable Indications.12-132 R-A5 R1.11 1SI-19 ISI08JA-11/2" W-07 X No Recordable Indications.12-133 R-A5 R1.11 1SI-19 1SI08JA-1lw" W-08 X No Recordable Indications.12-134 R-A 5 R1.1 1 1SI-19 1SI08JA-1" lW-09 X No Recordable Indications.12-135 R-A 5 R1.1 1 1SI-19 1SI08JA-1I lW-10 X No Recordable Indications.12-140 B-K B10.20 1SI-31 1Sl08JAA1lW W-1 5A X No Recordable Indications.12-207 B-G-2 1B7.50 1SI-17 1SIO8JB-Y2" FLG 1-4 X No Recordable Indications.12-138 B-G-2 B7.50 11SI-20 1SIO8JD-11/2" FLG 1-4 X Light rust noted, acceptable 12-210 AUG ECCS 1SI-30 l1 S09AA-1O" C03 X No Recordable Indications.12-209 AUG ECCS 1SI-28 ISI09AB-10" C03 X No Recordable Indications.12-211 AUG ECCS 1SI-30 ISI09AD-10" C08 X No Recordable Indications.12-127 R-A5 R1.16 1SI-13 1SI09BD-10" J25 X No Recordable Indications.12-143 R-A4 R1.20 l 151-37 1SI13BA-6" C03 X No Record Ind. Initial data.12-144 R-A4 R1.20 1S1-37 1SI13BA-6" C05 X No Record Ind. Initial data.12-145 R-A4 R1.20 ISI-37 1SI13C-6" C04 X No Recordable Indications.

Page 10 of 12

Exelon Byron Unit 1 Welds / Components B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Steam Blowdown (SD) Second Third

.CODE IE OETCCOMPONENTILINE. COMPOETIWL XMTP NUMBER CATEGORY " NTIFICATION . NUMB - SUR V VI -__-_v: ____,______- __

12-206 AUG HELB lSD-04 1SD53BD-6" C03.01 = X I.D. Geometry 3600 Intermittent.

Page 11 of 12

Exelon Byron Unit 1 Welds / Components B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL' PERIOD:

Steam Generators (SG) Second Third OBS C COEODEMISMERIC COPONENTIUNE CMPONENT I WELD EXAM TYPE:,

NUMBER CATEGORY *IDENTIFICATION . NME SURI VOL VtS__________________

12-116 B-D B3.140 1SG-07 1RC-01-BC N-1-NIR X No Recordable Indications.12-117 B-D B3.140 1SG-07 1RC-01-BC N-2-NIR X = No Recordable Indications.

Page 12 of 12

Exelon Byron Unit 1 BlR12 COMPONENT. CODE, EXAM

  • ,NEVES- M - cEQlM `

RVREQES

-- - .,' . MUENTS,12-203 1MS07BA E-2 C-C MT Attachment configuration 93.0% 2003-386 No Recordable Indications. Configuration limits access.12-109 1RH02AA-8' C20 C-C PT Attachment configuration 93.0% 2003-200 No Recordable Indications. Configuration limits access.

12.029 IRY-01-S PSL-01 B-K PT Lug location, Insulation, and seismic 21.4% 12R-21 2003-379 No Recordable Indications.

VT-1 restraint configuration 2003-380 I _ _ _ _ _ I__ I _ _ _ _ __I_ _ I _ _ _ I _ _ _ I _ _ _ _ _ I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Obstructed Examinations Page I of I

Exelon Byron Unit 1 Pressure Tests B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: . INTERVAL: PERIOD:

-Pressure Tests, All Systems Second' Third I CODE t- ITEM

-j-.,EXAMINATION ITEM/AREA -. - EINATION EXA-M,..*-, TYPE w.;

NUMBER S D R ...... -s -'

C-' , LEAK lPUNCTIONAL MN;(NOTE2);F l.INSERVICE .' PNEUMATIC .-- NOTE. -r CLASS I COMPONENTS B15.10 Reactor Vessel Pressure Retaining Boundry X _ 1 B15.20 Pressurizer Pressure Retaining Boundary X l 1 B15.30 Steam Generator Pressure Retaining Boundary l IRC011BA X 1 I

1 RC01BB3 X _ 1 1_RC01BC X 1 1_RC01BD X l 1 B15.50 Class 1 Piping Pressure Retaining Boundary X l 1 B15.60 Class I Pumps Pressure Retaining Boundary _

-____ 1RC01PA X l 1 1 RCOIPB X I 1RC01PC X I

_____ IRC01PD X 1 B15.70 Class I Valves Pressure Retaining Boundary X 1 CLASS 2 COMPONENTS C2.33 Nozzle-to-Shell (or Head) When Inside of Vessel is Inaccessible I RH02M RH-2-1 X IRH02AB RH-2-2 X _

C7.10 Pressure Vessels Pressure Retaining Components -

Chemical & Volume Control:

-____ 1CV01AACV-2-8 X ICV01AB CV-2-8 X 1CV02F CV-2-4 X ICV02A CV-2-4 X 1CV01FA CV-2-4 X ICV01FB CV-2-4 X ICV03AA CV-2-6 X ICV03AB CV-2-6 X 1CV04AA CV-2-5 X 1CV04AB CV-2-5 X I I -I I I a a a Page 1 of 7

Exelon Byron Unit 1 Pressure Tests BIR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Pressure Tests, All Systems Second Third EGTEM,-

ITEMAMINATIONTEMJAREA o EX - A T -

I NUMBER - (NOTE2):- LEAK ° FUNCTIONAL INSERVICE" ' 1PNEUMATIC--.- NOTE-C7.10 Residual Heat Removal: _ _

(cont'd) I RH02AA RH-2-1 X .

._____ 1 RH02AB RH-2-2 X . ;_.

C7.30 Piping, Pressure Retaining Boundary: _ . .

._______ Containment Spray: . _ . .

. CS-2-1 X . . .

CS-2-2 X . .

._______ Chemical & Volume Control: . . .

CV-2-1 X

.__-_- CV-2-2 . X

=_____ CV-2-3 = X = 3

._____ CV-2-4 X X .

._____ CV-2-5 . X .

CV-2-6 . X 4

______ ~~~~~~~~~~CV-2-7

__ _ _ X _ _ _ _ _ _ _ _

______ ~~~~~~~~~~CV-2-8

__ _ _ X_ _ __ _ _ _

______ ~~~~~~~~ ~~CV-2-9

_ _ _ _ _ __ X_ _ __ _ _ _

______ ~~~~~~~~~~CV-2-1 0 __ _ _ _ _ _ _ _ _ X 4

___ _ _ Fuel Pool Cooling: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

FC-2-1 X

._______ Fire Protection: . . . .

._____ FP-2-1 . X

.______ Feedwater: . .

FW-2-1 X

______ FW-2-2 X

_ Instrument Air:

. IA-2-1 . X 4 Main Steam: - MS-2-1 X .

______ ~ ~~~~~~~~~MS-2-1

_ _ _ _ _ __ X_ _ __ _ _ _

MS-2-2 X -

_______ Nitrogen: . . = = =_=_

______ ~~~~~~~~~~~NT-2-1

_ _ _ __ _ _ _ _ __ X 4

.___._ NT-2-2 . X 4

____._ NT-2-3 X 4

.NT-2-4 _ 4

_ _ I _ ______ I _ _ _ I_ _ I 1 I__ _

Page 2 of 7

Exelon Byron Unit 1 Pressure Tests B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Pressure Tests, All Systems Second Third WUETEM EXAMINATION ITEMIANEA__________

NUMBER - - -NOTh2). LEAK FUNCTIONAL- INSERVICE PNEUMATIC 'NOTE C7.30 Off Gas: .

(cont'd) OG-2-1 _ .

Primary Containment: .

.______ PC-2-1 X 4 Process Sampling:

._____ PS-2-3 X

._____ PS-2-4 X .

. _____ PS-2-5 -X . . .

-_____ PS-2-6 _ X Reactor Coolant: . ._.

RC-2-1 . X _

Residual Heat Removal:

._____ RH-2-1 X l . _.

RH-2-2 X .

RH-2-3 X

._____ RH-2-4 . X

._____ RH-2-5 X RH-2-6 ._. X Service Air: . .

SA-2-1 _ X 4 S/G Blowdown .

._____ SD-2-1 X Safety Injection: . .

-_____ Sl-2-1 . X

=_____ SI-2-2 X _

_____ 51-2-3 = X ==

-SI-2-5 _ _ _ _ X __ _ _ _ _ _ _ _ _ _ _

  • SI-2-6 __ _ _ X_ _ _ _ _ _ _ _

SI-2-7 _ _ _ _ X __ _ _ _ _ _ _ _ _ _ _

. SI-2-8 . X _ .

._-_. .1Sl-2-9 XX Service Water: . .

SX-2-1 . X . .

._____ SX-2-2 . X Page 3 of 7

Exelon Byron Unit 1 Pressure Tests BIR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL:. PERIOD:

Pressure Tests, All Systems Second Third CODE IT_ i EXWAMINATIONIITEMAREA

. . --. . .. .' .- ... EXAMINATION TYPE .. ...

NUMBER -. (NOTE2) .INSER

'LFM FUNCTONAL VICE -PNEUMATIC- -: NOTE!,-'

C7.30 Primary Containment Purge:

(cont'd) VQ-2-1 _ X 4 VQ-2-3 X 4 VQ-2-5 X 4 VQ-2-6 X 4 Make-up Demineralizer:

WM-2-1 X Chilled Water WO-2-1 X WO-2-2 X C7.50 Pumps, Pressure Retaining Boundary Containment Spray:

1CS01PA CS-2-1 X 1CS01 PB CS-2-2 X

_ Chemical & Volume Control:

1CV01PA CV-2-1 X 1CV01PB CV-2-2 X 1CV02P CV-2-3 X 3 Residual Heat Removal:

1RH01PA RH-2-1 X 1RH01 PB RH-2-2 X Safety Injection:

1SI101PA SI-2-1 X ISl01PB Sl-2-2 X C7.70 Valves, Pressure Retaining Boundary Contaiment Spray:

CS-2-1 X CS-2-2 X Page 4 of 7

Exelon Byron Unit 1 Pressure Tests BIR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL: PERIOD:

Pressure Tests, All Systems Second' Third

-CDETE X* -reti-t-. EXAMINATIONITEMJAREA  :-. i  :.EXAMINATION

,-;.i ., TYPE s  !-,-

-~

-NUMBER i-.

NOTE 2); LEAK -- FUNCTIONAL' INSERVCE - PNEUMATIC -NOTE C7.70 Chemical and Volume Control: . . .

(cont'd) CV-2-1 X

._ .___. CV-2-2 X

______ ~~~~~~~~~~~~~CV-2-3

__ _ _X _ _ 3 CV-2-4 .. . X . . _3

=__,_' CV-2-5 =___ =_ X =_____ I_____

______ ~~~~~~~~~~~~~CV-2-6

__ _ _X _ _

.__ _ '_ C V-2-7 ___ ___ X _ __ .__ __ '.__ _.__I

______ ~~~~~~~~~~~~CV-2-8

__ _ _ X _ _ _ _ _ _ _ _

.___._ CV-2-9 X _

CV-2-10 = l X 4 Fuel Pool Cooling: - FC-2-1 l X_ _

______ ~~~~~~~~~~~~~FC-2-1

__ _ _X _ _

Fire protection: FP-2-1 l X_._-_.

_______ ~~~~~~~~~~~ _ _ __ _ _ __ X_~~FP-2-1 _ _ _

Feedwater: . _ _

._____ FW-2-1 = X . -

______ ~~ ~~~~~~~~~~~FW 2 _ _ _ _ _ __ X_ _ __ _ _ _

=________ Instrument Air: IA-2-1 = = = X_4

_______ ~~~~~~~~~~~ __ _ _ _ _ _ _ _ _ _ _ _ X ~~IA-2-1 4 Main Steam: . .MS-2-1 X l MS-2-1 X

______ ~ ~~~~~~~~~~~~MS-2-2

_ _ _ _ _ __ X_ _ __ _ _ _

. _____ . _ Nitrogen:

______ ~~~~~~~~~~~ __ _ _ _ _ _ _ _4_ _ _ _ ~~NT-2-1 NT-2-2 X 4

______ ~~~~~~~~~~~ __ _ _ _ _ _ _ _ _ _ X ~~NT-2-3 4

=_____ NT-2-4 = X 4 Off Gas: __ l

=___-_ OG-2-1 X 4

=_______ Primary Containment: = X . 4

_______ ~~~~~~~~~~~ _ _ _ _ _ _ __ _ _ __ X ~~PC-2-1 4 Page 5of7

Exelon Byron Unit 1 Pressure Tests BlR12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL' PERIOD:

Pressure Tests, All Systems Second Third COEIE;- EXAMIATION ITEMIAREA ,- . EXAMINATION TYPE .-

NUMBER .-.- - *; '; (NOTE2)

IJUNI. -  :. LEAK'--FUN CTONAL - INSE - C . -PNEUMATIC -NOE-C7.70 Process Sampling: - _ - _

(cont'd) PS-2-3 X .

PS-2-4 _ X .

PS-2-5 x PS-2-6 X l Reactor Coolant:

l___._ RC-2-1 X . . -

Residual Heat Removal: ._._.

RH-2-1 X

._____ RH-2-2 l X RH-2-3 X

____._ RH-2-4 -_ l X . . -

l.____ RH-2-5 _ X RH-2-6 _ X . ._.

Service Air: - _ .

.____. SA-2-1 _ . X 4 S/G Blowdown: _ __

SD-2-1 _ X . -

Safety Injection: _ . . -

SI-2-1 X SI-2-2 X .

._____ SI-2-3 . _. X Sl-2-5 X . -

SI-2-6 _ X . . . -

Sl-2-7 X . . -

.SI-2-8 XX SI-2-9 X .

Service Water:

SX-2-1 . X

._____ SX-2-2 X . -

.___ Primary Containment Purge .

VQ-2-1 . X 4

._____ VQ-2-3 . X 4

.___ ._ VQ-2-5 X 4

.___._ VQ-2-6 . X 4 Page 6 of 7

Exelon Byron Unit 1 Pressure Tests B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: .NTERVAL: PERIOD:

EITEM Pressure Tests, All Systems Second Third 1 7D._  : -F -. EXAMNATO EM/ARE . . -.--. * -. .. MI TYP.

N..

') E i;"iLEAK (NOTE - FUNCTIONAL INSERVICE PNEUMATIC NOTE C7.70 Make Up Demeineralizer: ____ ________ ________

(cont'd) WM-2-1 X l Chilled Water:

____ WO-2-1 = = X =

_ _ _ _ _ ~ ~~~~~WO-2-2

_ _ _ _ _ __ X_ _ __ _ _ _

NOTE I The ASME Class 1 Pressure Boundary Leakage Test (VT-2) was performed on 9/22/03 and 10/12/03 to correspond to the pre- and post- ref ueling outage inspections.

NOTE 2 Refer to the System Pressure Test Summary for Subsystem Descriptions.

NOTE 3 The Inservice Inspection (VT-2) of CV-2-3 was performed with the exception of the Chemical Volume Control Positive Displacement Pump (1CV02P) and its associated piping and valves between the suction and discharge manual isolation valves. This Class 2 pump has been indefinitely taken out of service per Byron On-Site reviews92-088 and 93-006.

NOTE 4 Pneumatic test is conducted normal operating pressure, and is not a hydro test.

Page 7 of 7

Exelon Byron Unit 1 Containment Structure B1R12 OUTAGE INSPECTION

SUMMARY

SYSTEM: INTERVAL PERIOD:

CONTAINMENT STRUCTURE Second Third NUBDERE EXMINATION rYwAR A -. _. -.

  • E TYP -

NUM_______ -___________________

VISUAL -NT Accessible Surface Areas (MC Liner),

E1 11 100% of accessible surfaces X Relief Request 12R-38 approved for use by NRC,

. 100oexamined. current code used is ASME Section Xi, 1998 Edition Design Calculation BYR2000-181, Rev. 0 determined that the accessible surface area is 96.98% which meets the minimum of 80% required per IWE-1231 Moisture Barrier, 100% of barrier Relief Request 12R-38 approved for use by NRC, EI.30 examined. l current code used is ASME Section Xl, 1998 Edition exmnd.____ .______________.______

Page 1 of I

Exelkn.

Byron Station Unit I B1R12 ISI Outage Summary Report Support Outage Summary (Page 1 of 6)

SYSTEM: Chemical & Volume Control System (CV)

Section XI IS identifier Line Number I EPN l Exam Results Comments l Cat. Item Comments Summ F-A F1.20 1CV08005X 1CV05CB-61 CV08005X VT-3 NRI F-A*' F1.10 ICV02001C 1CVIODB-3/1CV02001C VT-3 NRI Exam performed due to RI on 1CV06009C F-A F1.10 1CV40001V ICV14FC-21CV40001V VT-3 NRI F-A F1.20 1CV08023X 1CV98BB-811CV08023X VT-3 NRI F-A F1.10 1CV15056X ICVA3B-211CV15056X - VT-3 NRI F-A F1.10 1CV16055X ICVA3B-21/CV16055X .VT-3 NRI F-A F1.10 1CV15022X 1CVA5M-2/1CV15022X VT-3 NRI F-A F1.10 1CV06006X 1CVB7A-3/1CV06006X VT-3 NRI Exam performed due to RI on 1CV06009C, (adjacent support)

F-A F1.10 1CV06009C ICVB7A-3/1CV06009C VT-3 RI No load on support, CR# 178080. WO 621066 adjusted support.

F-A F1.10 1CV06024X ICVB7A-3/1CV06024X VT-3 NRI Exam performed due to RI on 1CV06009C. (adjacent support)

Component Supports examined In accordance with Code Case N-491-1

  • Exelkn Byron Station Unit I BIR12 ISI Outage Summary Report Support Outage Summary (Page 2 of 6)

SYSTEM: Reactor Coolant System (RC).

Section Xi Cat. Item F-A F1.10 ISl Identifier Comments IRC01004V Line Number I EPN IRC21M-8/1RC01004V.

Exam Summary VT-3 Resu NF Ilts Comments

]'

F-A F1.10 1RC16013X 1RC22M-1-1/211RC16013X VT-3 NFU F-A F1.10 IRY06017X IRC24AA-4/1RY06017X VT-3 NF F-A F1.10 ICV06004V 1RC36A-3/1CV06004V VT-3 NFRl Exam performed due to RI on 1CV06009C (Same Une)

F-A F1.10 ICV06020C IRC36A-311CV06020C Vr-3 NRI Exam performed due to RI on ICV06009C, (same line)

Component Supports examined In accordance with Code Case N-491-1

Exeln.

Byron Station Unit I B1R12 ISI Outage Summary Report Support Outage Summary (Page 3 of 6)

SYSTEM: Residual Heat Removal System (RH)

Section Xi ISl Identifier Line Number I EPN Exam Results Comments Cat. Item Comments Summary F-A F1.10 1RH02065X IRHO1M-12/1RH02065X VT-3 NRI F-A F1.20 1RHO7004R IRH02M-811RH07004R VT-3 NRI F-A F1.20 1RH-CP1A 1RH02M-811RH-CP1A Vr-3: NRI F-A F1.20 1RH01006X IRH03M-8/1RH01006X VT-3 NRI F-A F1.20 1RH01007X IRH03M-8/1RH01007X VT-3. NRI Component Supports examined In accordance with Code Case N491-1

Exelkn.

Byron Station Unit I BIR12 ISI Outage Summary Report Support Outage Summary (Page 4 of 6)

SYSTEM: Reactor Coolant System (RY)

I Comments i Section Xi

  • Cat. Item

~~~I lSI Identifier IComments _

l Line Number I EPN lI I Exam SummarI. I Results

. ...I _.._,.. I.

F-A F1.10 1RY09077S 1RY02B-311 RY09077S VT-3 NRI F-A F1.10 1RY091W0S 1RY02B-3/1RY09100S VT-3 NRI Exams performed on'Trapeze snubber 1RY09100-SI &S2 F-A F1.10 IRY09101S 1RY06A-311RY09101S VT-3 NRI Component Supports examined In accordance with Code Case N491-1

  • Exelkn.

Byron Station Unit I BIRi2 ISI Outage Summary Report-Support Outage Summary (Page 5 of 6)

SYSTEM: Safety Iniectionl System (SI) l Section XI ISI Identifier Line Number I EPN Exam Results Comments

  • Cat. Item Comments l . Summary l ..

F-A F1AO 1SI06AO01X 1RH01SA/1SI06A001X VT-3 .NRI F-A F1.40 ISI06AO02R 1RH01SA/1SI06A002R VT-3 NRI F-A F1.10 1SI11003X 1SI03DA-V21S111003X VT-3 NRI F-A F1.10 ISI11005X 1SI03DA-2V1S111005X VT-3 NRI F-A F1.10 1SI11007X 1SI03DA-2V1S111007X VT-3 NRI F-A F1.10 1SI11015X ISI03DA-2V1SI11015X VT-3 NRI F-A F1.20 IRHO2100X 1S104B-1V21RH02100X VT-3 NRI F-A F1.10 1RH02017X 1SI04D-8/1RH02017X VT-3 NRI F-A F1.10 IRHO202OX 1SI04D-8/1RH02020X VT-3 NRI F-A F1.10 1RH02023X ISI04D-8/1RH02023X VT-3 NRI F-A F1.20 1S102002V 1SIOSCA-8/1SI02002V VT-3 NRI F-A F1.20 1S103008C ISI05CA-8/1SI03008C VT-3 NRI F-A F1.10 1S101014V 1SIO5DA-6I1SI01014V vr-3 NRI F-A F1.10 1SI01019X 1SIO5DA-611S101019X VT-3 NRI F-A F1.10 ISIOI021X ISI05DA-6/1SI01021X VT-3 NRI F-A F1.10 1SI01030X ISIOSDA-6/1SI01030X VT-3 NRI F-A F1.10 1S104017S iSIO5DB-6/1S104017S VT-3 NRI F-A F1.20 ISI0615OX 1SI06BB-24/1SI06150X VT-3 NRI F-A F1.10 1SI21018X ISIO8FA-311S121018X VT-3 NRI F-A F1.10 1S123001X ISI08FA-3/1SI23001X VT-3 NRI Component Supports examined In accordance with Code Case N-491-1

- Exelkn.-

Byron Station Unit 1 BIR12 ISI Outage Summary Report Support Outage Summary.

(Page 6 of 6)

SYSTEM: Safety Iniection System (SI)

Section X! ISl identifier LIneNumber/EPN Exam Results Comments Cat. ltem Comments Summary l F-A F1.10 1S123005X ISI08FA-3/1S123005X VT-3 NRI F-A F1.10 1SI23007X ISIO8FA-311S123007X VT-3 NRI F-A F1.10 1S123009X ISI08FA-3/1S123009X V1-3 NRI F-A F1.10 1SI0iO02S ISI09BA-iO1/1SI01002S VT-3 NRI F-A F1.20 1S115006X ISI13BA-6/1S115006X Vr-3 NRI F-A F1.20 1SI15010X ISI13BA-6/1SI1501oX Vr-3 NRI F-A F1.20 IRH02106X ISIA4A-8/1RH02106X VT-3 NRI Component Supports examined In accordance with Code Case N491-1

,Exelkn..

Byron Station Unit 1 B1RI2 ISI Outage Summary Report Snubber Outage Summary (Page 1 of.11)

SYSTEM: Component Cooling System (CC)

P Section Xi [SI identifier Line Number I EPN Exam Results Comments L

Cat. Comments Summary s I1 NIA

  • 1CC24013S ICC50B-3/1CC24013S VT-3 NRI N/A 1CC28019S ICC55M-314/1CC28019S VT-3 NRI N/A 1CC31019S ICC50AC-3/1CC31019S VT-3 NRI F.TEST PASS N/A 1CC31021S 1CC50AC-3/1CC31021S VT-3 NRI NIA ICC32001S ICC54AC-2/ICC32001S VT-3 NRI Note: Relief Request 12-R13. applies to all Technical Requirement Manual Snubbers

-Note: Section Xi Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

- Exelkn.

Byron Station Unit 1 BIR12 ISI Outage Summary Report Snubber Outage Summary (Page 2 of 11)

SYSTEM: Chemical & Volume Control System (CV)

Section XI ISI Identifier Line Number/ EPN

  • Exam Results Comments Cat. . Comments I I Summary .

F-A 1CV08006S ICV05CB-6/ICV08006S VT-3 NRI F-A ICV08010S 1CV05CB-6/iCV08010S VT-3 NRI F-A ICV08011S 1CV05CB-6/1CV0801iS VT-3 NRI F-A 1CV08013S 1CV05CB-6/1CV08013S VT-3 NRI F-A 1CV08021S 1CV05CB-16/1CV08021S VT-3 NRI F-A 1CV08027S ICV98C-8/1CV08027S VT-3 NRI F-A 1CV09005S ICVA3B-21/CV09005S VT-3 NRI F.TEST PASS F-A I CV09030S 1CVA6M-211CV09030S VT-3 NRI F-A ICV09050S 1CVA3B-2V1CV09050S VT NRI F-A 1CV09061-S1 IRC14AC-21ICV09061-SI VT-3 NRI F-A 1CV09061-S2 IRC14AC-21lCV09061-S2 VT-3 NRI F-A 1CV09063S 1CVA6M-211CV09063S VT-3 NRI F-A 1CV15039-S1 IRC14AB-2/1CV15039-S1 VT-3 NRI F-A 1CV15039-S2 IRC14AB-21lCV15039-S2 VT-3 NRI F-A 1CV15054S 1CVA5M-211CV15054S .VT-3. NRI F-A 1CV25007S ICVA7M-21CV25007S VT-3 NRI F.TEST PASS F-A 1CV25009S 1CVA7M-2i1CV25009S VT-3 NRI F-A 1CV25011S ICVA7AA-2/1 CV2501lIS VT-3 NRI F-A 1CV25014S ICVA7A-2/1CV25014S VT-3 NRI F-A 1CV25016S 1CVA7M-211CV25016S VT-3 NRI F-A 1CV25014S 1CVA3B-21CV25024S VT-3 NRI N.A 1CV27001S 1CV5AM-3/41CV25001S VT-3 NRI F-A NIA 1CV28002S 1CV28003S 1CV15A3B-3V/ CV28002S 1CV15AB-3/4/ICV28003S VT-3 VT-3 NRI N/A 1CV28003S 1CV1 5AB-31411 CV28003S VT1-3 NRI N/A 1CV29003S ICV15AC-314/1CV29003S VT-3 NRI Note: Relief Request 12-R13, applies to all Technical Requirement Manual Snubbers

,Note: Section Xl Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

: Exelk n..

Byron Station Unit I BIR12 ISI Outage Summary Report Snubber Outage Summary (Page 3 of 11)

SYSTEM: Chemical & Volume Control System (CV)

Section XI IS1 identifier Line Number I EPN Exam Results Comments

  • l Cat. lComments l ummarl l.l N/A. . CV30002S 1CV15AD-3/411CV30002S VT-3 NRI N/A 1CV52022S 1CV16BC-3/4/1CV52022S VT-3 NRI N/A ICV65011S ICV44AB-3/4/ICV65O11S VT-3 NRI F.TEST PASS F-A 1RY06097S 1RY18A-211RY06097S VT-3 NRI F-A 1RY06124S ICV45B-2/1RY06124S VT-3 NRI F-A 1RY06144S 1CV45B-2/1RY06144S VT NRI Note: Relief Request 12-R13, applies to all Technical Requirement Manual Snubbers Note: Section Xl Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

Exelon.

Byron Station Unit 1

-B1R12 [SI Outage Summary Report Snubber Outage Summary (Page 4 of 11)

SYSTEM: Main Steam Svstem (MS)

Section Xl ISI Identifier Line Number I EPN Exam Results Comments Cat. Comments . Summary F-A . 1MS01074-S1 1MS07AA-2811MSD1074-S1 VT-3 NRI F-A 1MS01074-S2 1MS07AA-28/1MS01074-S2 VT-3 NRI F-A 1MS01092-S1 IMS07AB-2811MS01092-S1 VT-3 NRI F-A 1MS01092-S2 1MS07AB-28/1MS01092-S2 VT-3 NRI F-A 1MS05007-S1 IMSO1AA-30.25/1MS05007-S1 VT-3 NRI F.TEST PASS F-A IMS05007-S2 IMSOIAA-30.25/1MS05007-S2 VT NRI F.TEST PASS F-A 1MS06007-S1 IMSO1AB-32.75/1MS06007-SI VT-3 NRI F-A 1MS06007-S2 1MSOIAB-32.75/1MS06007-S2 VT-3 NRI F-A 1MS07006-S1 1MSOIAC-32.75i1MS07006-S1 VT-3 NRI F-A 1MS07006-S2 MSO1AC-32.75 /1MS07006-S2 VT-3 NRI F-A 1MS08007-S1 1MS01AD-30.25/1MS08007-S1 VT-3 NRI F-A 1MS08007-S2 IMSOIAD-30.25/1MS08007-S2 VT-3 NRI Note: Relief Request 12-R13, applies to all Technical Requirement Manual Snubbers

  • Note: Section Xi Category numbers NIA-ed are exempt from IWF-1220 and IWF-2500 tables

Exelkn Byron Station Unit I 8iR12 ISI Outage Summary Report Snubber Outage Summary (Page 5 of 11)

SqYSTFM: Reactor Coolant Svstem (RC) .

Cat. Comments l Summary F-A ICV02003S 1RC37A-3/1CV02003S VT-3 NRI F-A ICV09038S IRC14AC-2/ICV09038S VT-3 NRI F-A ICV09066S 1RC14AC-211CV09066S VT-3 NRI F-A 1CV09067S IRC14AC-21lCV09067S V1T-3 NRI F-A 1CV09068S . 1RC14AC-2/1CV09068S VT-3 NRI F-A 1CV09069S 1RC14AC-21/CV09069S VT-3 NRI F-A ICV11019S IRC14AA-2/ICV11019S VT-3 NRI F-A 1CV11023S IRC14AA-21ICV11023S V1T-3 'NRI F-A 1CV12006S I.RCI6AA-211CV12006S VT-3 NRI F-A ICV15094S 1RC14AB-2V1CV15014S VT-3 NRI F-A ICV15040S 1RC14AB-2/ICV15040S V17-3 NRI F-A *ICV15041-Si 1RC14AB-211CV15041-Sl VT-3 NRI F-A ICV15041-S2 IRC14AB-2/ICV150O41-S2 VT-3 NRI F-A 1CV15053S 1RC14AB-211CV15053S VT-3 NRI F-A 1CV24026S IRC16AB-211CV24026S VT-3 NRI F-A ICV25006S. IRC14AD-2V1CV25006S VT-3 NRI F.TEST. PASS F-A 1CV25002S IRC14AD-211CV25002S. VT-3 NRI F.TEST 7PASS F-A 1CV25004S IRC14AD-211CV25004S. VT-3 NRI F.TEST PASS F-A 1CV1504S 1RC14AD-2V1CV25034-S VT-3 NRI F-A 1RC030065 IRC21AC-811RC03006S 2 VT-3 NRI F-A 1RC030085 IRC21AC-811RC030085 VT-3 NRI F-A IRC06S 1RC01BA-I1A1C2RC06S VT-3 NRI F-A IRC07S 1RC01BA-IA/1RC07S VT-3 NRI F-A 1RC08S 1RCOIBB-B4/IRC08S VT-3 NRI Note: Relief Request 12.Rl3. applies to all Technical RequIrement Manual Snubbers Note: Section Xi Category numbers N/A-ed are exempt from IWF-1 220 and IWF-2500 tables

Exelkn.

Byron Station Unit I B1R12 ISI Outage Summary Report Snubber Outage Summary (Page 6 of 11)

SYSTEM: Reactor Coolant System (RC)

Section Xl ISI Identifier Line Number I EPN Exam Results Comments Cat. Comments Summary  :

F-A I RC09S 1RCO1IBB-1B/1RC09S VT-3: NRI F-A IRC10S 1RCO1lBC-1C/1RC10S VT-3 NRI F-A 1RC11S 1RC01BC-1C/IRC11S VT-3 NRI F.TEST PASS F-A 1RC12S IRC01BD-1D/IRC12S VT-3 NRI F-A IRC13S 1RCO1BD-1D/1RC13S VT-3 NRI N/A 1RC16010S 1RC20AA-314/IRC16010S VT-3 NRI F-A 1RC16011S IRC22AA-1.5/1RCI6013 S VT-3 NRI F-A '1RC16016S 1RC22M-1.511RCI616S VT-3 NRI F.TEST PASS F-A 1RC16024S 1RC22M-1.5/1RC16024S VT-3 NRI F-A 1RC17003S 1RC22AB-i.5/1RC17003S VT-3 NRI N/A 1RC17012S 1RC20AB-3/4/1RCI7012S VT-3 NRI F-A 1RC17015S - RC22AB-1.5/1RC17015S VT-3 NRI N/A 1RC17025S 1RC08AB-3/411RC17025S VT-3 NRI F-A 1RC17028S 1RC22AB-i.5/1RC17028S VT-3 NRI F-A IRC18006S 1RC22AC-1.5/1 RC1 8006S VT-3 NRI

F-A IRC18010S 1RC22AC-1.5/1RC1801OS VT-3 NRI N/A 1RC18015S 1RC20AC-3/411RC18015S VT-3 NRI

- N/A 1RC1 8020S 1RC08AC-3/4/1RC18020S VT-3 NRI N/A 1RC19004S * -RC20AD-3/411RC19004S VT-3 NRI

- ' F.TEST PASS F-A 1RCI 9007S I RC22AD-1.5/1 RC19007S VT-3 NRI N/A 1RC19021S 1RCO8AD-3/4/1RC19O21S ' VT-3 NRI F.TEST PASS N/A I RC1 9023S 1RC08AD-3/4/1 RCI 9023S VT-3 NRI F.TEST PASS N/A 1RC1 9024S 1RC20AD-314/1 RC1 9024S VT-3 NRI Note: Relief Request 12-R13, applies to all Technical Requirement Manual Snubbers Note: Section Xl Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

- Exelkn.

Byron Station Unit 1 BIR12 ISI Outage Summary Report-Snubber Outage Summary (Page 7 of 11)

SYSTEM: Reactor Coolant System (RC)

Section XI IS1 Identifier lLine Number I EPN Exam Results lComments Cat. IComments I - Summary I . . I.

F-A IRCI 9027S 1RC22AD-1.511RC19027S. VT-3 NRI F-A 1RY600b8S 1RC24AB-4/1 RY06008S VT-3 NRI F-A IRY06015S 1RC24M411 RY06015S Vr-3 NRI F-A I RY06032S 1RC24AB-411 RY06032S VT-3 NRI F-A I RY06055S 1RC24AA-411 RY06055S VT-3 NRI F-A 1RY06056S IRC24AA-411RY06056S Vr-3 NRI Note: Relief Request l2-R13, applies to all Technical Requirement Manual Snubbers Note: Section Xl Category numbers N/A-ed are exempt from IWF-i220 and IWF-2500 tables

Exeln.

Byron Station Unit I BIR12 ISI Outage Summary Report .

Snubber Outage Summary (Page 8 of 11)

SYSTEM: Residual Heat Removal System (RH)

Section Xl i1I Identifier Llne Number/ EPN Exam Results Comments Cat. Comments . Summary F-A . 1RH020545 . 1RHO1M-12J1RH02054S VT-3 NRI NIA IRHO2102S 1RH26AB-3/4/1RH02102S VT-3 NRI F-A IRHO2107S IRHOIM-121lRH02107S VT-3 NRI.

NIA 1RHO2112S- IRH26M-31411RH02112S VT-3 NRI F-A IRHO8015S . 1RH02AB-811RH08015S VT-3 NRI Note: Relief Request 12-R13, applies to all Technical Requirement Manual Snubbers Note: Section XI Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

- Exelkon.

Byron Station Unit I

  • BIR12 ISI Outage Summary Report

- Snubber Outage Summary (Page 9 of 11)

SYSTEM: Reactor Coolant System (RY)

Section XI IS1 Identifier Line Number/ EPN Exam Results Comments ,

l Cat-, lComments llSmayl *,

F-A IRY06012S 1RY01ABl4/1RY06012S VT-3 NRI F-A 1RY06022S iRY01B-6/1RY06022S VT-3 NRI F-A i RY06025S ,, IRYOIB-6/1RY06025S VT-3 NRI F-A 1RY06026S IRY018-6/1RY06026S VT-3 NRI F-A ' RY06027S IRY01B-6/11RY06027S VT-3 NRI F-A 1RY06030S 1RY01B-6/1RY06030S VT-3 NRI F-A IRY06031S 1RY01B4-611RY06031S VT-3 NRI F-A IRY06059S 1RY01AA411RY06059S VT-3 NRI F-A 1RY06066S IRYO1AA4/1RY06066S VT-3 NRI F-A 1RY06076S IRY01B-611RY06076S VT-3 NRI F-A 1RY06118-S1 1RY01B-6/1RY06118-S1 VT-3 NRI F-A -IRY06118-S2 IRY011-611RY06118-S2 VT-3 NRI F-A 1RY06121S 1RY01AA4/1RY06121S VT-3 NRI F-A I RY09005S 1RY02B-3/1 RY09005S VT-3 NRI F-A IRY09012S - IRY06A-3/1RY09012S . VT-3 NRI F-A 1RY09077S - I RY02B-3/i RY09077S VT-3 NRI.

F-A 1RY09078-S1 1RY06B-31IRY09078-S1 VT-3 NRI F.TEST PASS F-A 1RY09078-S2 1RY06B-3/1 RY09078-S2 VT-3 NRI

- , F.TEST PASS F-A 1RY09100-SI IRY02B-3/1RY09100-S1 Vr-3 NRI F-A IRY09100-S2 IRY02B-3/1RY09100-S2 VT-3 NRI F-A IRY09101S 1RY06A-3/1RY09101S VT-3 NRI Note: Relief Request 12-R13, applies to all Technical Requirement Manual Snubbers Note: Section Xi Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

Exelkn.

Byron Station Unit I BIR12 ISI Outage Summary Report Snubber Outage Summary (Page 10 of 11)

SYSTEM: Steam Generator Blowdown System (SD)

I . . . .

.1 I

Section X Cat.

ISI identifier Comments Line Number I EPN I Exam Summary I

Results Comments I__ _

I.

N/A . 1SD22015S I.1SDO1CE-2/1SD22015S VT-3 NRI Note: Relief Request 12-Ri 3. applies to all Technical Requirement Manual Snubbers

'Note: Section XI Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

Exelon.

Byron Station Unit 1 BiR12 ISI Outage Summary Report Snubber Outage Summary (Page 11 of 11)

SYSTEM. Safetv Iniection Svstem (Sl) .

Section XI Cat.,

IS1 Identifier Comments l Line Number IEPN Exam lSummary Results "l

IComments':'-

F-A 1SIO1002S ISI09BA-10/ISIO1002S VT-3 NRI F-A 1SI01003S 1SI109BA-10/1SI01003S VT-3 NRI F-A 1SI01004S ISI09BA-10/1SIO1004S VT-3 NRI F-A 1SI01025S ISI05CA-8/1SI01025S, VT-3 NRI F-A 1SI01029S ISI05DA-611SI01029S VT-3 NRI F-A 1SI02003S ISIS5CA-8/1S02003S VT-3 NRI F-A 1S103003S 1SI05CA8/1S103003S VT-3 NRI Snubber had a cold setting of 1-518'with F.TEST PASS a movement of 1-9/16- In compression.

Acceptable as-is. Snubber was adjusted to Its maximum cold setting 1-13116 on WO 508399.

F-A 1S103046-S1 ISI05DD-611SI03046-S1 VT-3 NRI F-A 1SI03046-S2 1SI05DD-6/1S103046-S2 VT-3 NRI F-A 1SI04003S ISI09BB-10/1SI04003S VT-3 NRI F-A 1SI04017S ISI05DB-6/1SI04017S VT-3 NRI F-A 1SI04024S ISI05CB-8/1SI04024S VT-3 NRI F-A 1S109006S SIOS5CB-8/1SI09006S VT-3 NRI F-A 1SI09021S ISI09BC-10/1S109021S VT-3 NRI F-A 1S109024S 1SI09BC-10/1SI09024S VT-3 NRI F-A 1SI09043S 1SI05CB-8/1SI09043S VT-3 NRI':

N/A 1S116037S 1SI18ED-211SI16037S VT-3 NRI Note: Relief Request 12-Ri 3, applies to all Technical Requirement Manual Snubbers '

Note: Section Xl Category numbers N/A-ed are exempt from IWF-1220 and IWF-2500 tables

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61 01 0 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Chemical & Volume Control System Piping Welds & Components (CV)

Component or Manufacturer or Manufacturer or State or Province National Board Appurtenance Installer l Installer Serial No. Number l Number C3.30 1ICV-01 -PA Pacific Pumps 49770 Not Applicable 198 ICV5CA-6" Hunter Corp. 1-C0V-2-N5 Not Applicable Not Applicable CAT 4/RI .20 1CV05CBB8 CAT 4/RI1.20 Hunter Corp. I-CV-2-N5 Not Applicable Not Applicable 1CV98CB-8" Hunter Corp. 1-CV-2-N5 Not Applicable Not Applicable CAT 4/R1.20 I1ICV98C-8" CV98BA-8" Hunter Corp.

Hne op 1-CV-2-N5 Not Applicable Not Applicable CAT 4/RI .20 H/R1.2b Hute Cop-CV-2-N5 Not Applicable Not Applicable CATCVA3AA-2" CA .115/Ri Hunter Corp.

Hunter Corp. 1-CV-2-N5 I-CV-2-N5NoAplcbeotpliae Not Applicable Not Applicable I CV 9A5 -2"__ _ _ _ _ _

CAT 5/Ri. 1 C/R1.V3 1 Hunter Corp. 1-CV-1-N5 Not Applicable Not Applicable 1CVA6AA-2" Hunter Corp. I-CV-1-N5 Not Applicable Not Applicable CAT5/R1.11 ~Hunter Corp. 1-CV-1-N5 Not Applicable Not Applicable I CV A 5A A-2" _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Computer Generated Form Page I of 22 -

B1R12, FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant) 3; Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Feedwater System Piping Welds & Components (FW) lComponent or Appurtenance lManufacturer or l Installer j Manufacturer.or Installer Serial No. } State or Province Number l National Board Number CFW03DD 1 Hunter Corp. l 1-FW-1-N5 Not Applicable Not Applicable AUG-HELB IF~W8IBD-6"T AU Hunter Corp. 1-FW-1-N5 l Not Applicable *Not Applicable AUG-HELB UFW87CD-6"1 W.A. Pope Corp. 1-FW-1-N5 Not Applicable Not Applicable Computer Generated Form Page 2 of 22

BlR12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit:* One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Main Steam System Piping Welds & Components (MS) rl Component or l Appurtenance l Manufanufacture Installer r oranufacturer or l State or Province lInstaller Serial No. Number l National Board Number l AUG-HELB l MSO1BA-30%" Hunter Corp. 1-MS-1 -N5 Not Applicable Not Applicable C3.20 l1MS07BA-28wl Hunter Corp. I-MS-1-N5 Not Applicable Not Applicable I. .7BA,2.

Computer Generated Form Page 3 of 22 -

BlR12, FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Reactor Coolant System Piping Welds & Components (RC)

Component or l Manufacturer or Manufacturer or l State or Province l National Board l Appurtenance I Installer Installer Serial No. I Number Number CAT 4/R1 .20 IRC13AA-2" Hunter Corp. 1-RC-1-N5 Not Applicable Not Applicable CAT 4/R1 .20 CA 4/RCI3AB0Hunter Corp. 1-RC-1-N5 Not Applicable Not Applicable CAT 4/RI1 .20A b 1RCI4AC-2 " Hunter Corp. I-RC-1-N5 Not Applicable Not Applicable CAT 4/R1.20 1RCI 3AD-2" Hunter Corp. I-RC-1-N5 Not Applicable Not Applicable I RC14A D-2" HtCr1___ApclNpia CAT 2/R1.1I1 1IRC224AB./2" Hunter Corp. 1-RC-1 -N5 Not Applicable Not Applicable CAT 2/RI11rAo 2/RI .11 Hunter Corp. 1-RC-1-N5 ab Not Applicable Not Applicable RCIAC-11 I 11-C-N2" CAT 2/RI1.1 Hunter Corp. 1-RC-1 -N5 Not Applicable Not Applicable 1RCI4AD-1./29 Hunter Corp. 1-RC-1-N5Not Applicable Not Applicable CAT 2/RI1.1 1

~ RCIAB.2~

1RC4ACA-2' Hunter Hunte Corp.

Corp. 1-RC-1-N5 1-RC-1-N5 Not Applicable NotAppl Not Applicable cable CAT 2/RI1.1 1 IRC2IAB8" Hunter Corp. 1-RC-1-N5 Not Applicable Not Applicable I1RC16AA-12? Hne op -R--5NtApiabe NtApial CAT 4/RI..20 1A" IRC22AA-1 Hunter Corp. I-RC-1-N5 Not Applicable 'Not Applicable 1/ "

IRC22A-1 Hunter Corp. I-RC-1-N5 Not Applicable Not Applicable 2

B7.50 1 /?

IRC22AD-1 Hunter Corp. I-RC-1-N5. Not Applicable Not Applicable IRC-0I-PD HWetinuer Corp. 4-RC-11-N5I Not Applicable NotAplicbl Computer Generated Form Page 4 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial.Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Residual Heat Removal Welds & Components (RHR)

Component or Manufacturer or Manufacturer orj State or Province National Board Appurtenance Installer Installer Serial No. Number Number 10 C Inge-PA Corsolratond 127428 Not Applicable 167 1 RH-01-PA Corporation__ _ _ _ _ _ __ _ _ _ _ _ _ _ _

AUG-TRACK IRH-02-AA Joseph Oat Corp. 2267-IA U122326 836

.1 RH02-Ap 1CRH02AA8 Hunter Corp. 1-RH-1-N5. Not Applicable Not Applicable CAT 4/R .20

. RH02AA-8" Hunter Corp. 1-RH-I-N5. Not Applicable Not Applicable Computer Generated FormP Page 5 of 22 -

B1R12.

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: No t Applicable'
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Reactor Pressure Vessel Welds & Components (RPV)

[ Appurtenance B14.10 Installer [

Component or l Manufacturer or I Manufacturer or.

Installer Serial No.

State or Province Number National Board Number N-198 IRC-01-R Westinghouse Corp. 640-0004-51 B-09061 N-198 B7.1 0 IRC-01-R Westinghous e Corp. 640-0004-51 B-09061 N-1 98 Computer Generated Form P.age 6 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comerciai Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Pressurizer Spray and Relief System Piping Welds & Components (RY)

Component or l Manufacturer or Manufacturer or State or Province l National Board Appurtenance l Installer l Installer Serial No. l Number l Number l B7.50 1IRYO3BA-6" Hunter Corp. 1-RY-1-N5 Not Applicable Not Applicable B7.50 CATYO3BC-61 Hunter Corp. 1-RY-1-N5 Not Applicable Not Applicable CAT 2/RI1.1 1 IRY11A-14" Hunter Corp. 1-RY-1-N5 Not Applicable Not Applicable CAT 2/RI1.11I 1RY1 8A-2" Hunter Corp. 1-RY-1 -N5 Not Applicable Not Applicable l7.50 Hunter Corp. 1-RY-1-N5 Not Applicable Not Applicable I RY76A-2_

Computer Generated Form Page 7 of 22 -

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: No t Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Pressurizer Vessel Welds & Components (PZR)

Component or Manufacturer or Manufacturer. or State or Province National Board Appurtenance l Installer Installer Serial No. Number Number B10.10 Westinghouse U-201291 W13580 1RY-01 -S Corporation 1721 Computer Generated Form Page 8 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant) 3; Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09116/85 6. National Board Number of Unit: N-198
7. Components Inspected: Steam Blowdown Welds & Components (SD) lComponent or l Manufacturer or l Manufacturer or l State or Province l National Board Appurtenance Installer' Installer Serial No. l Number Number l AUG-HELB W.A. Pope AUG SD53B D-6 Corporation Not Applicable. Not Applicable Not Applicable

.S5BD6 Coprto . ...

Computer Generated Form Page 9 of 22

B1R12-FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: No t Applicable
5. Comercial Service Date: 09116/85 6. National Board Number of Unit: N- 198
7. Components Inspected: Steam Generator Welds & Components (SG)

Component or 1 Manufacturer or Manufacturer or l State or Province 1 National Board Appurtenance j Installer Installer Serial No. Number l Number B3.140 Babcock & Wilcox 7722-01 ILU-242902 164 1 RC-01-BC Industries . .

_ _ _ _ _ I _ _ _ I __ I __ i Computer Generated Form Page 10 of 22 -

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit:, One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-1 98
7. Components Inspected: Safety Injection System Piping Welds & Components (SI)

Component or l Manufacturer or - Manufacturer or l State or Province l National Board Appurtenance l Installer j Installer Serial No. Number [ Number CAT 4/R1I20 .2SI-2-N5 2NotApplicable 0NotApplicableHunterCorporation CAT 5/R1.1I Hunter Corporation 1-Sl-2-N5 Not Applicable Not Applicable CAT5/RIO811/" Hunter Corporation 1-SI-1-N5 Not Applicable Not Applicable' 1S08FA-3" H tC oi___ - t pcet la CAT 5/R1.11 IS108GC-11 " Hunter Corporation 1-SI-1-N5 Not Applicable Not Applicable B7.50 CAT 1 5HA-21 Hunter Corporation 1-SI-1-N5 Not Applicable Not Applicable CAT 5/R1.1 1 Hunter Corporation 1-SI-1 -N5 Not Applicable Not Applicable I S108HA-2C B7.50CCS Hunter Corporation 1-SI-1-N5 Not Applicable Not Applicable 1IO.209 AD10 Hunter Corporation 1-SI-1 -N5 Not Applicable Not Applicable I1SI08JA-I A" _ _ _ _ _ _ _ _

CAT 5/R1.111-SI-I Hunter Corporation -N5Not Applicable Not Applicable 1SI08JA-1 1 A"__ _ _ _ _ _ _ _

B7.50 ISIO8JB-IY? Hunter Corporation 1-SI-I-N5 Not Applicable Not Applicable B7.50 ISIO8D-I%"Hunter Corporation I-SI-I1-N5 Not Applicable Not Applicable AUG-ECCS ISIO9A-I0"Hunter Corporation 1-SI-I1-N5 Not Applicable Not Applicable 3B-6"Hunter Corporation SiS1 1-SI-1-N5 Not Applicable Not Applicable l AUG-ECCS ISIO9D-I0"Hunter Corporation 1-SI-I1-N5 . Not Applicable Not Applicable

~~~~

CAT Hunter Corporation 1-SI-2-N5 Not Applicable Not Applicable CAT 4/RI. 62 1S113C-6" Hunter Corporation I-Sl-2-N5 Not Applicable Not Applicable Computer Generated Form .Page II of 22

BlR'12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class I System Pressure Tests Component or Appurtenance BIS.10 l

l Manufacturer or Installer Westinghouse Manufacturer orl Installer Serial No.

640-0004-51 I State or Province Number B-09061 l

l National Board Number N-198 Vessel 1RC-01-R Corporation II 815.10 Westinghouse . 640-0004-52 B-09061 N-198 Head I RC-01 -R Corporation B15.20 Westinghouse 1721 U-201291 W13580 IRY-01-S Corporation __

B15.30 Babcock & Wilcox 7720-02 ILU-242904 165 I RC-01-BA Incorporated B15.30 Babcock & Wilcox 7720-03 ILU-242903 166 1RC-01-BB Incorporated B15.30 Babcock & Wilcox 7720-01 ILU-242902 164 I RC-01 -BC Incorporated B15.30 Babcock & Wilcox 7720-04 ILU-242901 167 I RC-01 -BD Incorporated 772004_LU-2290_16

.Class Piping Hunter Corporation Not Applicable Not Applicable Not Applicable B15.60 Westinghouse 1-115E121-G01 NotApplicable W25819 1RC-01 -PA Corporation .1511GNoAplaeW28 815.60 Westinghouse W52 B1C5.60B Corpoationg s 2-115E121-GOI Not Applicable W25820 1 RC-01 -PB Corporation 815.60 . Westinghouse 3-115E121-GO1 . NotApplicable W25821 I RC-01 -PC Corporation 815.60 Westinghouse 4-115E121-GOI Not Applicable W25822 IRC-01 -PD Corporation N A c B15.70 Hunter Corporation Not Applicable Not Applicable Not Applicable Class 1 Valves Computer Generated Form Page 12 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests Component or l Manufacturer or Manufacturer or l State or Province ' National Board Appurtenance Installer' Installer Serial No. Number Number I C2.33 Joseph Oat I RH-02-AA Corporation 2267-1A U122326 836 C2.33 Joseph Oat 2267-IB U122327 837 1RH-02-AB Corporation 1CV01AA Atlas 3197 U187655 2575 07.10E Atlas 3198 U187654 .2576.

ICV01 PMAB ________ _20 C7.10 1CV01FA Pall Trinty Micro 38305 N/A 21087 C7.1 0 ICVOIFB Pall Trinty Micro 38307 N/A 20189 07.10 Atlas 3454 U-187662 2877 ICV 02A__ _ _ _ _ _ __ _ _ _ _ _

07.10 1ICVO2F Pall Trinty Micro 38327 N/A 21109 C7.10 1ICVO3AA Atlas 3390 U187652 2769 ICVO3AB Atlas 3382 U187653 2761 07.10 Joseph Oat 2268-1A U187661 905 1CV04AA Corporation C7.10 Joseph Oat 1 CV04AB ICVO4AB Corporation Corporation ~2268-1lB U187660 906 C7.10 Joseph Oat 1RH-02-AA Corporation 2267-1A U122326 836 07.1 0 C7.10 Joseph Joseph OatOat ~~~~~2267-11B U122327 837 1RH-02-AB Corporation 2 C7.30 Hunter Corporation Not Applicable Not Applicable Not Applicable CS-2-1 07.30 C0 CS-2-2 Hunter Corporation Not Applicable Not Applicable Not Applicable

. C.S-'2-.2 Computer Generated Form Page 13 of 22

B1R12' FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

Component or 1 Manufacturer or Manufacturer or l State or Province National Board Appurtenance [ Installer Installer Serial No. Number [ Number l C7.30 CV-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable 97.30 CV-2-2 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 C CV-2-3 Hunter Corporation Not Applicable Not Applicable Not Applicable CV-2-2 C7.30 CV-2A Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 C7.30 CV-2-5 Hunter Corporation CV-2-6 Not Applicable Not Applicable Not Applicable C7.30 CV-2-7 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 C7.30 C7.308 Hunter Corporation Not Applicable' Not Applicable Not Applicable FC21Hunter Corporation Not Applicable Not Applicable Not Applicable CVC27. Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 CV-2-9 Hun ter Corporation Not Applicable Not Applicable Not Applicable C7.30 CV-2-1 Hunter Corporation Not Applicable -Not Applicable Not Applicable FW22Hunter Corporation Not Applicable* Not Applicable Not Applicable C7.30 IA21Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 MS21Hunter Corporation Not Applicable Not Applicable Not Applicable Computer Generated Form Page 14 of 22

BlR12.

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant) 3.' Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

Component or Manufacturer or l Manufacturer or. State or Province l National Board Appurtenance Installer l Installer Serial No. Number Number C7.30 MS-2-2 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 NT2Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 NT-2-1 NT-2-' Hunter Hute_ Corporation ororton Not Applicable NtppiabeoApicblotAplcal Not Applicable Not Applicable NT-2-3 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 NT Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 OG3P-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 PC-2-i Hunter Corporation Not Applicable Not Applicable Not Applicable 30 PS-231Hunter Corporation Not Applicable Not Applicable Not Applicable PC-2-6 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 RH22Hunter RC-2-1 Hunter Corporation Corporation Not Applicable Not Applicable Not Applicable Not Applicable Not Not Applicable Applicable C7.30'.30 RH-2-1 Hunter C .'PR-2-3 Corporatio Hunter Corporation Not ApplicableNot Applicable Not Applicable Not Applicable NtApplicable C7.30 RH-2~ Hunter Corporation Not Applicable 'Not Applicable Not Applicable Computer Generated FormP Page 15 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules 1.Owner: Exelon Generation Company, LLC,4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)

2. Plant: Byron Nuclear PowerStation, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

[ Component or Appurtenance Manufacturer or Installer Manufacturer or Installer Serial No. l State or Province Number National Board]

Number C7.30 RH-2-5 Hunter Corporation Not Applicable Not Applicable NotApplicable C7.30 RH-2-6 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 C7.30- utrCroain NtApial o plcbe NtApial SA-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 SD.2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 51-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable CSI2-3'Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30~~ 512-2 Hunter Corporation *Not Applicable Not Applicable Not Applicable C7.30 SI-2-6 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 ~SX-2-3 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 51-2-5 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 S1-2-8 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 SQ-2-5 Hunter H .. Corporation 4Not Applicable Not Applicable Not Applicable*

C7.30 5127Hunter Corporation Not Applicable Not Applicable Not Applicable VQ23Hunter Corporation Not Applicable Not Applicable Not Applicable Computer Generated FormP Page 16 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

F Component or Appurtenance Manufacturer or Installer Manufacturer or Installer Serial No.

- State or Province Number National Board Number C7.30 C7 6Hunter Corporation VQ2- Not Applicable. Not Applicable Not Applicable VQ-2-5 _ _ _ _ _ _

C7.30 WM21Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 C7.

WM.2. Hunter Corporation Not Applicable Not Applicable Not Applicable 1C30 -PA 2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.30 WO--2-2Hunter P Corporation Not Applicable Not Applicable Not Applicable C7.50 Ingersoll Rand21 1CS-01-PB CS-2-2 C7.50 Corporation IgrolRn 1076123 Not Applicable 220 1C7501P Ingersol 1 CV02-PCV-2< Hulnte Randicm Corporation 107612 Not1344-1bl Not Applicable Not Applicable N 2201 353piabe C7.50SIC-01-PA Cl-2-1 Pacific Pump 14975870 Not Applicable 221 ICS-Ol-PA CS-2-1 Corporation 12748_'._NtApliabl_'__16 1CS1-01-pB C-2-2 Pacific Pump 49771 Not Applicable 201 C7.50 IHCV-02-P CV-2-3 Gaulin Corporation 641344-1 Not Applicable 353 C7.50 Ingersoll Rand 127428 A Not Applicable 167

.RH-01-PA RH-2-1 Corporation NtpibeoA lc eoApcl C7.50

. Ingersoll Rand ~~127429 Not Applicable .159 1RH-01-PB RH-2-2 Corporation________

C7.5023 ISI-Ol-P51-2-1 Pacific Pump 49758 Not Applicable23 C SI-01-BSI22 Pacific Pump 49759 Not Applicable 231 C7.70 CS2-1Hunter C orporation Not Appli[cable Not Applicable Not Applicable C7.70 CS22Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70.

CV-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable Computer Generated FormP Page 17 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

Component or Manufacturer or l Manufacturer or l State or Province j National Board l Appurtenance Installer l Installer Serial No. l Number Number C7.70 CV-2-2 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CV24Hunter Corporation Not Applicable Not Applicabl e Not Applicable C7.70 CV-2-3 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CV-2-8 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CV-2-5 Hunter Corporation Not Applicable Not Applicable Applicable C7.70 CCV-2-6 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CV-W2-71Hunter Corporation *Not Applicable Not Applicable Not Applicable C7.70 FC-2-7 C7C70 V-2-8 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CV-2-9 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CV-2-1 0 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 FC-2-1 Hunter Corporation Not Appli cable Not Applicable Not Applicable C7.70 FP21Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 FW22Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70A2-1Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 MS-2-.1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 MS-2-.2 Hunter Corporation Not Applicable Not Applicable~ Not Applicable C7.70 NT-2-11 Hunter Corporation Not Applicable Not Applicable Not Applicable Computer Generated Form Page 18 of 22

BlR12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

Component or l Manufacturer or Manufacturer.or l State or Province National Board Appurtenance Installer Installer Serial No. Number Number C7.70 NT-2-2 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 NT-2-3 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 NT-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 C7.70 OG-2-1 Hunter Corporation PS23Hunter Corporation Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable C7.70 PC-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable PC-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 RP-2-3 C7.70 PS-2-64 utrCroain NtApial o plcbe NtApial C7.70 P Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70

.RC-215Hunter Corporation Not Applicable Not Applicable Not Applicable RH22Hunter RH-2-6 Hunter Corporation Corporation Not Not Applicable Applicable Not Not Applicable Applicable Not Not Applicable Applicable C7.70 NtApial RH-2-1 Hunter Corporation 'Not Applicable Not Applicable NtApial C7.70 RH.~Hunter Corporation Not Applicable Not Applicable Not Applicable C7.7RH2-5Hun ter Corporation Not Applicable Not Applicable Not Applicable C7.7RH2-6Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 SA21Hunter Corporation Not Applicable Not Applicable Not Applicable Computer Generated FormP Page 19 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Class 2 System Pressure Tests (cont'd)

Component or Manufacturer or l Manufacturer.or State or Province National Board Appurtenance Installer l Installer Serial No. l Number Number C7.70 SD21Hunter Corporation Not`Applicable l Not Applicable l Not Applicable 07.70 SI-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable Not C7.70 07.70 51 SI-2 Hunter Corporation Hunter Corporation Not Applicable Not Applicable Not Not Applicable Applicable Not Applicable Applicable 07.70 CSI-2-3 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 SI-2-Hunter Corporation Not Applicable Not Applicable Not Applicable 07.70 SI-2-6 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 CSI-2-7 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.70 SI-2-5 Hunter Corporation Not Applicable Not Applicable Not Applicable 07.70 07.70 SI-2-9 Hunter Corporation Not Applicable Not Applicable Not Applicable SX7V-2-I Hunter Corporation Not Applicable Not Applicable Not Applicable 07.70 07.70H t o aNA cNA cop a C7.70 7.70 SX-2-2 Hunter Corporation WM-2-1 Not Applicable Not Applicable Not Applicable SX-2-6 Hunter Corporation Not Applicable Not Applicable Not Applicable Hunter Corporation

,7-2-7 Hunter 07.70 WM-2-1 Corporation Not Not Applicable Applicable Not Not Applicable Applicable Not Not Applicable Applicable 07.70 WOQ-2-1 Hunter Corporation Not Applicable Not Applicable Not Applicable C7.7007.70 WO-2-2 Hunter Corporation VQ25Hunter Corporation Not Applicable Not Applicable Not Applicable Not Applicable Not Not Applicable Applicable Computer Generated FormP Page 20 of 22

BlR12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner: Exelon Generation Company, LLC, 4300 Winfield Road, Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: One (1) 4. Owner Certificate of Authorization: Not Applicable
5. Comercial Service Date: 09/16/85 6. National Board Number of Unit: N-198
7. Components Inspected: Containment Structure (PC)

[ Component or Appurtenance Manufacturer or Installer Manufacturer or Installer Serial No.

State or Province Number National Board Number E1.11 Chicago Bridge and Not Applicable Not Applicable N-198 MC Liner Iron Company ._.

E1.30 Chicago Bridge and Not Applicable Not Applicable N-I98 Moisture Barrier Iron Company Applicable NotAplicabl_____

Computer Generated Form Page 21 of 22

B1R12 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

8. Examination Dates: March 30, 2002 to October 14, 2003
9. Inspection Interval: June 30, 1996 to June 30, 2005
10. Abstract of Examination.

Include a list of examinations and a statement concerning status or work required for current interval.

Refer to the Outage Summary Report and ISI Program Plan.

11. Abstract of Conditions Noted.

Refer to the Outage Summary Report.

12. Abstract of Corrective Measures Recommended and Taken.

Refer to the Outage Summary Report.

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate or Authorization No. (if applicable): N/A Expiration Date: N/A Date: //s /Z C( Signed For: Exelon Generation Company By:

CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and' Pressure Vessel Inspectors and the State or Province of Illinois and employed by Hartford Steam Boiler of CT. have inspected the components described this Owner's Report during the period 03/30102 to 10/14103, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report.

Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Inspectors Signature Commissions: ILL-1254 Date: , 20 P4 National Board, State, Province, and Endorsements Computer Generated Form Page 22 of 22 -

Exelkn.

BYRON STATION UNIT I BIRi2 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FIOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

'(Page I of 8)

1. Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Narm and Address of Owerw)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Flant)
3. Plant Unit: 14. Owner Certificate Of Auithorization NIA.
5. Commercial Service Date: 09/16185 6. National Board Number for Unit: N-198
7. Components Inspected: Chemical & Volume Control System (CV)

Manufacturer Component or Appurtenance

_ _ _ _ __a 1

I Manufacturer orInstaller I oro Inataller Serial N o._

l State or Province No.

National Board No.

SUPPORT HUNTER CORPORATION ICV05CB- NMA NIA 6/ICV08005X SUPPORT HUNTER CORPORATION 1CV10DB- N/A N/A

. . 3/ICV02001C SUPPORT HUNTER CORPORATION ICV14FC- N/A N/A 2/1CV40001V SUPPORT HUNTER CORPORATION 1CV98BB- N/A N/A

. 8/1CV08023X SUPPORT. HUNTER CORPORATION ICVA3B- N/A N/A 2/1CV15056X SUPPORT. HUNTER CORPORATION -CVA3B- N/A N/A 2/1CV16055X SUPPORT HUNTER CORPORATION ICVA5AA- N/A N/A 2/1 CV15022X SUPPORT HUNTER CORPORATION ICVB7A- N/A N/A

.______________________ 3/1 CV06006X SUPPORT HUNTER CORPORATION 1CVB7A- N/A N/A 3/ICV06009C SUPPORT HUNTER CORPORATION ICVB7A- N/A N/A 3/1CV06024X Component Supports examined In accordance with Code Case N-491-1 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 In. x II In.,

(2) Information In Items I through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

ConVWnr Genetd Form

- -Exelon-BYRON STATION UNIT I BIR12 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 2 of 8)

1. Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Name and Address of Owner)

.2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, lilinois 61010 (Name and Address of Plant)

3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Reactor Coolant System (RC)

Component or Manu Manufacturer State or l National Appurtenance I or Installer' or.lnstaller Province No. I Board No.

I _ _ __ __ _ _ _ _ _ I Serial N o. _ _ _ _ _ _ _

SUPPORT HUNTER CORPORATION. I RC21M- N/A - N/A 8/11RC01004V -

SUPPORT HUNTER CORPORATION IRC22M N/A N/A 1i2/11RC16013X SUPPORT. HUNTER CORPORATION IRC24M- N/A N/A

- .

  • 4/IRY06017X SUPPORT HUNTER CORPORATION IRC36A- N/A N/A 3/1 CV06004V SUPPORT HUNTER CORPORATION IRC36A- *N/A N/A 3/ICV06020C Component Supports examined In accordance with Code Case N-491-1 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 11 in;;

(2) information In items 1 through 6 of this report Is inciuded on each sheet, and (3) each sheet Is numbered and the number of sheets is.recorded at the top of this form.

compWnr Genhetdd Fonn

-BYRON BYRO Exelen..

STATION UNIT I BIR12 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 3 of 8) 1., Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Name and Address of Owner) 2.' Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name end Address of Plant)

3. Plant Unit: .1 4. Owner Certificate Of Authorization N/A 5.. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Residual Heat Removal System (RH)

Manufacturer Component or Manufacturer State or National or Installer "

Appurtenance or Installer Province No. Board No.

Serial No.

SUPPORT 'HUNTER

  • CORPORATION' 1RHOIM- N/A N/A

.____ _ _ 12/1 RH02065X SUPPORT HUNTER CORPORATION 1RH02AA- N/A. N/A 8/1 RHO7004R .

SUPPORT HUNTER CORPORATION CIRHOAA-8/lRH- N/A N/A

  • ~C PIA_ _ _ _ _ _ _ _ _ _ _

SUPPORT. HUNTER CORPORATION 1RH03M- N/A N/A 8/IRH01006X ._._.

SUPPORT. HUNTER CORPORATION iRHO3M- . N/A N/A

.. . . 8/IRH01007X . ._._.

Component Supports examined in accordance with Code Case N491-1 Note: Supplemental sheets Inform of iists,'sketches, or drawings may be used, provided (1)size Is8 112 in. x 111n.,

(2)Information In items 1 through 6 of this report is included on each sheet, and (3)each sheet Isnumbered and the number of sheets is recorded at the top of this form.

ConputarGenfatd Form

Exelon-BYRON STATION UNIT I BIR12 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 4 of 8)

1. Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Name and Address of Owner)

.2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)

3. Plant Unit: .1 4. Owner Certificate Of Authorization . N/A
5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Reactor Coolant System (RY)

Component or Appurtenance l a

or Installer 1 Manufacturer o Installer State or Province No. l National Board No.

_ _ _ __ __ __ _I __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I Serial N o . I _ _ _ _

SNUBBER PACIFIC SCIENTIFIC . I RY02B- N/A NIA

.___.___.___ .___.___. _ 3/1RY09077S ._._:

SNUBBER PACIFIC SCIENTIFIC IRY02B-. N/A N/A

.____. ____.____. ____. __ 3/1 RY 0910 S ._._..

SNUBBER PACIFIC SCIENTIFIC 1RY06A- NA . NIA

.____.____.____. ___. _ 3/1 RY09101S -_._.

Component Supports examined In accordance with Code Case N491-1 Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 1/2 In. x I Iin.,

(2) Information In Items I through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Computer Goeneated Foim

BYO Exelon.

: BYRON STATION UNIT I BIR12 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 5 of 8)
i. Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Narne and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Narne and Address of Plant)
  • 3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: .. 09/16/85 6. National Board Number for Unit: N-198,
7. Components Inspected: Safety Injection System (SI)

Component or Manufacturer Manufacturer State or National.

Appurtenance or Installer Serial No. Province No. Board No.

SUPPORT HUNTER CORPORATION' IRHOISA11SI06AOO N/A N/A w .~~~~~~~~X SUPPORT HUNTER CORPORATION 1RH01SA/1S106A00 N/A N/A 2 R_ _ _ _ _ _ _ _ _ _ _ _

SUPPORT. HUNTER CORPORATION 1SI03DA- N/A N/A

.____.___.___. ___ .___ '__ 2/1SI11003X '_._.'_._.

SUPPORT HUNTER CORPORATION ISI03DA- N/A N/A

._____________________ _ .2/1SI11005X SUPPORT HUNTER CORPORATION 1SI03DA- N/A N/A

.... 2/1SI11007X SUPPORT HUNTER CORPORATION 1SI03DA- N/A N/A

._ _ _ _ _. _ _ _ _ _. _ _ _ _ _. _ _ _ 2/1 S I11015X . _.. _ _.. _. _

SUPPORT HUNTER CORPORATION 1SI04B- N/A N/A 12/1 RHO210OX .O.O.X._

SUPPORT .HUNTER CORPORATION ISI04D- N/A N/A 8/1 RH02017X SUPPORT HUNTER CORPORATION 1SI04D- N/A N/A 8/1 RHO202OX ._.

SUPPORT HUNTER CORPORATION' 1SI04D- N/A N/A

.8/1 RH02023X

. SUPPORT'. ' HUNTER CORPORATION ISI05CA- N/A N/A

. . . . .' 8/1SI02002V .

SUPPORT HUNTER CORPORATION 1SI05CA- N/A N/A 8/15103008C' ._'_ '_'

SUPPORT, HUNTER CORPORATION ISI05DA- N/A . N/A

._____.. ______. _____. ___ 6/1SI01014V . . .. _ _ _ . _.

Component Supports examined In accordance with Code Case N491-1 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 1¶ In:;

(2) information In items I through 6 of this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

CompuerGenwated Form

Exelkn BYRON STATION UNIT I BIR12 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

'(Page6of8)

1. Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Name and Address of Owner)
  • 2. 'Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010

.t(Nane

  • and Address of Plant)
3. Plant Unit: .1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09116185 . 6. National Board Number for Unit: N-198
  • 7. Components Inspected: Safety Injection System (SI)

Component or Manufacturerr1i State or National Appurtenance or Installer or nsller Province No. oard No.

SUPPORT 'HUNTER CORPORATION I1S105DA- N/A N/A

.___________________ . _ 6/1 5101019X SUPPORT HUNTER CORPORATION ISI05DA- N/A. N/A

._____'_____._____ .____ 6/1SIOI021X ._.

SUPPORT HUNTER CORPORATION 'SI05DA- 'NIA NIA

. _._____ ___________ __._ _._ _ '___. _ _. _ _ ._ 6/1 S 101030X . ._'

SNUBBER PACIFIC SCIENTIFIC 1SI05DB- N/A N/A 6/1 SlO401 7S SUPPORT. HUNTER CORPORATION 1SIO6BB- N/A NIA

_ __ 24/1

_ S106150X SO SUPPORT HUNTER CORPORATION ASI08FA- N/A N/A

'._______________ _. 3/15121018X . _ .'

SUPPORT HUNTER CORPORATION ISI08FA- N/A N/A

' :_____.____.____'___. _ 3/1S123001X .

SUPPORT HUNTER CORPORATION 1SI08FA- N/A . N/A

.______. ______' ___ _ .__ 3/11SI23005X SUPPORT HUNTER CORPORATION 1SI08FA-. N/A N/A

.. ____.___.__.___.___. _ 3/1SI23007X .

SUPPORT HUNTER CORPORATION ISI08FA- N/A N/A

.. _________________ . _ '3/1S123009X . .

.SNUBBER PACIFIC SCIENTIFIC ISI09BA- N/A N/A 10/1 SIO1002S .

  • SUPPORT HUNTER CORPORATION ISI13BA- N/A N/A

.___._____ __. .6/15115006X ._.

'SUPPORT HUNTER CORPORATION- 1SI13BA- N/A N/A

._________. _________. _ _ 6/1SI1501O X .

Component Supports examined'in accordance with Code Case N-491-1 Note: Supplemental sheets In form of lists, sketches, or drawings may be used. provided (1) size Is 8 112 In. x 11 in.,

(2) Information In Items 1 through 6 of this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.

computer Gfnted Form

Exelin.

BYRON STATION UNIT 1 BIR12 ISI OUTAGE REPORT.

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 7 of 8)

1. Owner: Exelon Generation Company, (LLC), 4300 Winfield Rd., Warrenville, IL 60555 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Narmeand Address of Pant)
3. Plant Unit: 1 4.' Owner Certificate Of Authorization N/A
5. Commercial Srvice Date: 09/16/85 6. National Board NumberforUnit: N-198
7. Components Inspected: Safety Injection System (SI)

Component or Manufacturer Appurtenance or Installer I..

SUPPORT l HUNTER CORPORATION.

Component Supports examined In accordance vAth Code Case N-491-1 Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 11 In; (2) information in Items 1 through 6 of this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

  • Cornputer Gerad ForM

Exelkn-

-BYRON STATION UNIT I BIR12 ISI OUTAGE REPORT FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 8 of 8)

(BACK)

8. Examination Dates 03/30/02 to 10/14/03
9. Inspection Interval: 06/30/96 to 06/30/05
10. Abstract of Examination.

Include a list of examinations and a statement concerning status of work required for current interval.

Refer to the Outage Summary Report and [SI Program Plan I1. Abstract of Conditions Noted.

Refer to the Outage Summary Report

12. Abstract of Corrective Measures Recommended and Taken.

Refer to the Outage Summary Report We certify that the statements made in this report are correct and the examination and corrective measures taken conform to the rules of ASME Code,Section XI.

Certificate of Authorization No. (if applicable): N/A Experation Date: NIA Date: _ //_ A_ Of Signed for:Exelon Generation Company By:-.'/<fi CERTIFICATE OF INSERVICE INSPECTION I,the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford CT. have inspected the components described in this Owner's Report during the period 03130102 to 10114/03 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report.

Futhermore, neither the Inspector-nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

" Inspectors Signature Commissions: Date: ,20 04 .

National Board, State, Province, and Endorsements Computer Geneated Font

Exelkn.

Byron Station Unit 1.

BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page I of 17) 1; Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address o Owner)

2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Component Cooling System (CC)

Component or Manufacturer Manufacturer. State or National Appurtenance or Installer orialler. Province No. Board No.

Serial No.

SNUBBER PACIFIC SCIENTIFIC 1CC24013S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CC28019S N/A N/A SNUBBER . LISEGA 1CC31019S N/A N/A.

SNUBBER PACIFIC SCIENTIFIC ICC31021S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CC32001S N/A N/A Note: Supplemental sheets in form of lists.,sketches, or drawings may be used, provided (1) size is 8 112 In. x 11 In..

(2) Information In Items 1 through 6 of this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.

Computer Genated Form

Exelkn.

Byron Station Unit I BIR12 ISI.Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 2 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348.

(Name and Address of Owner)

2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)

.3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A

5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: . N-198
7. Components Inspected: Chemical & Volume Control System (CV)

Manufacturer .

Manufacturer State or National Component or Appurtenance or Installer o Staller. Province No. Board No.

Serial No. _ _ _ _ _ _ _ _ _ _ _ _ _

SNUBBER PACIFIC SCIENTIFIC 1CV08006S NIA . NIA SNUBBER PACIFIC SCIENTIFIC 1CV08010S N/A NIA SNUBBER PACIFIC SCIENTIFIC 1CV08011S N/A N/AI.

SNUBBER PACIFIC SCIENTIFIC 1CV08013S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV08021S N/A N/A SNUBBER . PACIFIC SCIENTIFIC 1CV08027S N/A N/A SNUBBER PACIFIC SCIENTIFIC ICV09005S NIA NIA SNUBBER PACIFIC SCIENTIFIC 1CV09030S N/A.. N/A SNUBBER PACIFIC SCIENTIFIC ICV09O5OS N/A N/A SNUBBER . PACIFIC SCIENTIFIC 1CV09061-SI N/AM N/A SNUBBER PACIFIC SCIENTIFIC. .1CV09061-S2 N/A N/A

. SNUBBER PACIFIC SCIENTIFIC 1CV09063S N/A . N/A SNUBBER PACIFIC SCIENTIFIC 1CV15039-SI N/A N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 1/2 In. x 11 In.;

(2) information In Items 1 through 6 of this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.t Comubtr Genrated Form

Exelkn.

Byron Station Unit I B1R12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 3 of 17) 1 Owner: Exelon Generation Company,(LLC), 200 Exeloin Way, Kennett Square, PA 19348 (Name and Address of Owner).

  • 2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 .

(Name and Address of Plant)

3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09/16/85 6., National Board Number for Unit: N-198
7. Components Inspected: Chemical & Volume Control System (CV)

Component or Manufacturer Manufacturer State or National

. AppurtenanceAppurtenanceor or Installer Installer Sorialler.

~Serial No. Province No. Board No..

SNUBBER PACIFIC SCIENTIFIC 1CV15039-S2 N/A N/A SNUBBER PACIFIC SCIENTIFIC I CV1 5054S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25007S N/A N/A

.SNUBBER . PACIFIC SCIENTIFIC 1CV25009S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25011 S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25014S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25016S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25024S N/A N/A SNUBBER PACIFIC SCIENTIFIC .1CV27001S N/A N/A SNUBBER PACIFIC SCIENTIFIC *1CV28002S N/A N/A

..SNUBBER PACIFIC SCIENTIFIC 1CV28003S N/A N/A SNUBBER PACIFIC.SCIENTIFIC 1CV29003S N/A N/A SNUBBER PACIFIC SCIENTIFIC' 1CV30002S N/A N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8 112 In. x 11 In.,

(2) Information In Items I through 6 of this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Corputer Generated Fonn

Exelkn..

Byron Station Unit 1 BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 4 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Nane and Address of Owner) .

.2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)

.3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A

5. Commercial Service Date: .09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Chemical & Volume Control System (CV)

Manufacturer.

  • State or National Component or Manufacturer or Installer Appurtenance or Installer Province No. Board No Serial No.

SNUBBER PACIFIC SCIENTIFIC 1CV52022S N/A N/A I.'.

SNUBBER PACIFIC SCIENTIFIC 1CV65011S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY06097S . N/A . N/A SNUBBER PACIFIC SCIENTIFIC IRY06124S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY06144S N/A N/A I

Note: Supplemental sheets In form of lists,'sketches, or drawings may be used, provided (1) size Is 8 112 In. xI1 in.,

(2) information in Items 1 through 6 of this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.

Convuter Glnated Form

Exelkn, Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 5 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Narne and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09/16/85 6. National Board Numberfor Unit: N-198.
7. Components Inspected: Main Steam System (MS)

Component or Manufacturer Manufacturer State or National Appurtenance or Installer Serial No. Province No. Board No.

SNUBBER PACIFIC SCIENTIFIC 1MS01074-S1 N/A' N/A SNUBBER PACIFIC SCIENTIFIC IMS01074-5 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS01092-S1 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS01092-S2 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS05007-S1 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS05007-S2 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS06007-SI N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS06007-S2 N/A. N/A SNUBBER. PACIFIC SCIENTIFIC 1MS07006-S1. N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS07006-S2 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS08007-S1 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1MS08007-S2 N/A N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 11 in;;

(2) Information In Items 1 through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Computer Gomrated Form .

Exelkn.

Byron Station Unit I BIR12 IS Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

  • (Page 6 of 17)
1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Narne end Address of Owner),
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 .

(Name and Address of Plant)

3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09116/85 6. National Board Number for Unit: N-198
7. Components Inspected: Reactor Coolant System (RC)

Component or Manufacturer Manufacturer State or National Appurtenance or Installer orialler. Province No. Board No.-

Serial No.

SNUBBER PACIFIC SCIENTIFIC 1CV02003S N/A . N/A SNUBBER PACIFIC SCIENTIFIC 1CV09038S N/A - N/A SNUBBER PACIFIC SCIENTIFIC 1CV09066S . NIA N/A SNUBBER PACIFIC SCIENTIFIC 1CV09067S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV09068S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV09069S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV11039S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV11023S N/A N/A SNUBBER PACIFIC SCIENTIFIC .CV12006S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV1 5014S N/A N/A SNUBBER PACIFIC SCIENTIFIC: I CV1 5040S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV15041-SI N/A N/A

.SNUBBER PACIFIC SCIENTIFIC' ICV15041-S2 N/A. N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 1/2 In. x 11 in.,

(2) Information in Items 1 through 6 of this report Is Incuded on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Conputer Generad Form

-:-ByronExern.

Station Unit 1 BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 7 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Narne and Address of Owner)
  • 2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Reactor Coolant System (RC)

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province No. Board No..

Serial No.

SNUBBER PACIFIC SCIENTIFIC 1CV15053S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV24026S N/A N/A SNUBBER PACIFIC SCIENTIFIC I CV25001S N/A N/A.

SNUBBER PACIFIC SCIENTIFIC 1CV25002S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25004S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1CV25034S . N/A N/A SNUBBER PACIFIC SCIENTIFIC IRC03006S N/A N/A SNUBBER PACIFIC SCIENTIFIC I1RC03008S N/A.. N/A

. SNUBBER PAUL MUNROE 1RC06S N/A N/A SNUBBER PAUL MUNROE 1RC07S N/A- N/A SNUBBER PAUL MUNROE IRC08S . N/A N/A

. . SNUBBER PAUL MUNROE 1RC09S N/A N/A SNUBBER PAUL MUNROE IRC10S N/A N/A Note: Supplemental sheets in form of lists, sketches, or drawings may be used, pmvided (1) size Is 8 1/2 In. x 11 in:;

(2) Information In Items 1 through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.:

Comnputer Geratd Form

Exelkn.

Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 8 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348.

(Narme and Address of Owner)

2. Plant: Byron Nuclear Power Station,4450 North German Church Road, Byron, lllinois 61010 (Name and Address of Plant)

.3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A

5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Reactor Coolant System (RC)

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or ns aller Province No. Board No.

Serial No.

SNUBBER PAUL MUNROE IRC11S N/A N/A SNUBBER PAUL MUNROE 1RC12S N/A N/A SNUBBER PAUL MUNROE 1RC13S N/A - N/A SNUBBER PACIFIC SCIENTIFIC IRC16010S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRC16011S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRC16016S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RCI 6024S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRC17003S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRC17012S N/A *N/A SNUBBER PACIFIC SCIENTIFIC 1RC17015S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRCI 7025S N/A N/A SNUBBER PACIFIC SCIENTIFIC I RC1 7028S N/A N/A SNUBBER PACIFIC SCIENTIFIC I RCI 8006S N/A N/A Note: Supplemental sheets Inform of lists, sketches, or drawings may be used, provided (1)size Is8 1/2 In.x I1 In;,

(2)Information InItems 1 through 6 of this report IsIncluded on each sheet, and (3)each sheet Isnumbered and the number of sheets Isrecorded at the top of this form.

Conputer Generated Form

Exelkn Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 9 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
  • 2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization. N/A
5. Commercial Service Date: 09/16/85 6. National Board Numberfor Unit: N-198
7. Components Inspected: Reactor Coolant System (RC)

Component or Manufacturer Manuturer State or National

. Appurtenance . or Installer Province No. Board No.

Serial No.

. SNUBBER PACIFIC SCIENTIFIC . IRCI8OIOS N/A. . N/A SNUBBER PACIFIC SCIENTIFIC 1RC18015S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRC18015S N/A N/A SNUBBER* PACIFIC SCIENTIFIC 1RC18020S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RCI9004S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RC19007S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RC19021S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RC19023S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RC19024S N/A N/A

. SNUBBER

.1RY06 PACIFIC SCIENTIFIC NA/

SNUBBER PACIFIC SCIENTIFIC 1RC19027S N/A N/A SNUBBER PACIFIC SCIENTIFIC I1RY06008S N/A N/A SNUBBER . PACIFIC SCIENTIFIC 1RY06015S N/A N/A SNUBBER PACIFIC SCIENTIFIC I RY06032S N/A N/A SNUBBER . PACIFIC SCIENTIFIC I1RY06055S N/A N/A Note: Supplemental sheets In form of lists, sketches. or drawings may be used, provided (1) size is 8 1/2 in. x 11 In.,

(2) Information In Items 1 through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Compur Generad Form .

Exelkn.-

Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 10 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner):
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 .
  • (Namneand Address of Plant)
3. Plant Unit: :1I 4. Owner Certil ricate Of Authorization: N/A
5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Reactor Coolant System (FIC)

Manufacturer Component or *Manufacturer State or National or Installer Appurtenance or Installer Province No. Board No.'

4. 4.

Serial No. 1 5 SNUBBER PACIFIC SCIENTIFIC 1RY06056S N/A: N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 11In.,

(2) Information In Items 1 through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Computer Generad Form

Exelon..

Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 11 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348.

(Name and Address of Owner)

2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date:  :.09/16/85 6. NationalBoardNumberforUnit:. N-198.
7. Components Inspected: Residual Heat Removal System (RH)

Component or Manufacturer Man State or National Appurtenance or-Installer Serial No. Province No. Board No.

SNUBBER PACIFIC SCIENTIFIC 1RH02054S N/A . N/A SNUBBER PACIFIC SCIENTIFIC IRHQ21025 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RHO2107S N/AM, NIA .

SNUBBER PACIFIC SCIENTIFIC IRHO2112S N/A N/A SNUBBER PACIFIC SCIENTIFIC IRHO8015S N/A NIA Note: Supplemental sheets in form of lists, sketches, ordrawings maybe used, provided (1) size Is 8 112 In.xII In.;

(2) Information In Items I through 6 of this report Is Included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.

Cornp G~enerated Form

Exelkn.

Byron Station Unit I

eB1R12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 12 of 17) 1; Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner).
2. Plant: Byron Nuclear Power Station, 4450 North German'Church Road, Byron, Illinois 61010 (Narne and Address of Planr)
3. Plant Unit: 1 4.. Owner Certificate Of Authorization N/A 5.'Commercial Service Date: 09/16/85 6. National Board Numberfor Unit: N-198
7. Components Inspected: Reactor Coolant System (RY)

Component or Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province No. Board No.-

SNUBBER PACIFIC SCIENTIFIC .1RY060125 N/A N/A SNUBBER PACIFIC SCIENTIFIC I1RY06022S N/A ' NIA SNUBBER PACIFIC SCIENTIFIC 1RY060252S' N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY060265S NIA N/A SNUBBER PACIFIC SCIENTIFIC 1RY06027S N/A N/A SNUBBER' PACIFIC SCIENTIFIC 1RY06030S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY06030S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY06031S N/A N/A SNUBBER PACIFIC SCIENTIFIC - 1RY06059S N/A N/A SNUBBER PACIFIC SCIENTIFIC .1RY06066S N/A N/A SNUBBER PACIFIC SCIENTIFIC .1RY06076S NIA*- N/A SNUBBER PACIFIC SCIENTIFIC 1 IRY06118-Sl N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY06118-S2 N/A N/A

' -SNUBBER ' PACIFIC SCIENTIFIC' 1RY06121 S NIA ' 'N/A Note: Supplemental sheets In form of lists: sketches, or drawings may be used, provided (1) size Is 8 1/2 in. x 11 In.,

(2) Information In Items I through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.

Coputer Generated Form

Exelion' Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 13 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Nane and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A
5. Commercial Service Date: . 09/16/85 6. National Board Number for Unit:. N-198
7. Components Inspected: Reactor Coolant System (RY)

Component or Manufacturer . Manufacturer State or National Appurtenance or Installer ori Ntler Province No. Board No.

Serial No.

SNUBBER PACIFIC SCIENTIFIC IRY09005S N/A N/A

. SNUBBER PACIFIC SCIENTIFIC *1RY09012S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1RY09077N N/A N/A

. SNUBBER PACIFIC SCIENTIFIC 1 RY09078-S1 N/A N/A SNUBBER PACIFIC SCIENTIFIC 1 RY09078-S2 . N/A N/A

  • SNUBBER . PACIFIC SCIENTIFIC I RY09078-S2 N/A N/A

. SNUBBER . PACIFIC SCIENTIFIC IRY09100-Sl . N/A N/A- .

SNUBBER PACIFIC SCIENTIFIC I RY09100-S2 N/A N/A SNUBBER PACIFIC SCIENTIFIC IRY09101S WN/A. N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 11 In:;

(2) Information In items I through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.:

Comper Genrated Form

Exelkn.

Byron Station Unit 1 BIR12 1SI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 14 of 17) 1; Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner):

  • 2. Plant: Byron Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization VNA
5. Commercial'Service Date: 09/16/85 6.. National Board Number for Unit: N-198

-7. Components inspected: Steam Generator Blowdown System (SD)

. Component or . Manufacturer Manufacturer State or National Appurtenance or Installer or Installer Province No. Board No.

Serial No.

SNUBBER PACIFIC SCIENTIFIC ISD22015S N/A. N/A Note: Supplemental sheets In form of lists; sketches. or drawings may be used, provided (1) size Is 8 1/2 In. x 1i in.,

(2) Information In items I through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Copua Ganerated Form

Exern.

Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 15 of 17)

1. Owner: Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Narne and Address of Owner)
2. Plant: Byron'Nuclear Power Station, 4450 North German Church Road, Byron, Illinois 61010 (Narme and Address of Rant)
3. Plant Unit: 1 4. Owner Certificate Of Authorization N/A 5.. Commercial Service Date: 09/16/85 6. National Board Number for Unit:. N-198:
7. Components Inspected: Safety Injection System (SI)

Component or Manufacturer Manufacturer Statebor National Appurtenance or Installer orInstaller Province No. Board No.

SNUBBER_._PACIFICSCIENTIFIC SerialNo. _ _ _ . _:___

SNUBBER PACIFIC SCIENTIFIC 1SI01002S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1SIO1003S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1SIO1004S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1S101025S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1SIOI029S .N/A N/A SNUBBER PACIFIC SCIENTIFIC 1S102003S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1SI03003S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1SI03046-Si N/A. N/A SNUBBER. PACIFIC SCIENTIFIC 1SI03046-S2. N/A N/A SNUBBER PACIFIC SCIENTIFIC' 1S104003S N/A' N/A SNUBBER PACIFIC SCIENTIFIC' . 1SI04017S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1S104024S N/A ' . N/A SNUBBER PACIFIC SCIENTIFIC 15S09006S N/A . N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used. provided (1) size Is 8 112 In. x I1 In..

(2) Information In items I through 6 of this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Computor Generated Form

Exeln.

Byron Station Unit I BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules (Page 16 of 17) 1; Owner Exelon Generation Company,(LLC), 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner).

.2. Plant: Byron Nuclear Power Station,4450 North German Church Road, Byron, Illinois 61010 (Namneand Address of Plant)

3. Plant Unit: 1 4. Owner Certificate Of Authorization .N/A
5. Commercial Service Date: 09/16/85 6. National Board Number for Unit: N-198
7. Components Inspected: Safety Injection System (SI).

Component or Manufacturer Manufacturer State or National Appurtenance or Installer orialler.

Serial No. Province No. Board No'.

SNUBBER PACIFIC SCIENTIFIC 15109021S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1S109024S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1S109043S N/A N/A SNUBBER PACIFIC SCIENTIFIC 1S116037S N/A N/A Note: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size Is 8 112 In. x 11 in.,

(2) information in Items 1 through 6 of this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

Comter Gon*rad Fonn

- Exelkn Byron Station Unit 1 BIR12 ISI Outage Report FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

  • : : (Page 17 of 17)

(BACK)

8. Examination Dates 03/30/02 to 10/14/03
9. Inspection Interval: 06/30/96 to 06/30/05
10. Abstract of Examination.

Include a list of examinations and a statement concerning status of work required for current Interval.

Refer to the Outage Summary Report and ISI Program Plan

11. Abstract of Conditions Noted.

Refer to the Outage Summary Report

12. Abstract of Corrective Measures Recommended and Taken.

Refer to the Outage Summary Report We certify that the statements made in'this report are correct and the examination and corrective measures taken conform to the rules of ASME Code, Section XI:

Certificate of Authorization No. (if applicable): N/A Experation Date: N/A Date: Signed for: Exelon Generation Company CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford CT. have inspected the components described in this Owner's Report during the period 03/30/02 to 10114/03 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's eport in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report.

Futhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or roperty damage or a loss of any kind arising from or connected with this inspection.

6 co Inspectors Signature Commissions: ILL-I254 Date: * ,.,. § , 20 .

National Board, State, Province, and Endorsements Computer Generated Form

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT

- As Required by the Provisions of the ASME Code Section XI

1. ' Owner Exelon Nuclear Name Date 9U16/O3

. I I 4300 Winfield Rd. Warrenville, 11. 60555 Sheet I of 1 Address

2. Plant Byron Nuclear Power Station Unit 00 Name 4450 N. German Church Road, Byron,. II. -Work Order No. 00603188-03 Address . . Repair Orpnization. P.O. No., Job No., etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp -Not Applicable Nane Authorization No. Not Applicable 4450 N. German Church Road, Byron, Il. Expiration Date Not Applicable Address 4: Identification of System fABJ BORIC ACID
5. (a) Applicable Construction Code Section III 19 71 Edition,W/72 Addenda,N/A 'Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components.

Maine at atI Ma~~~~~ne - ~~N~atioa Yw Repired. - 1 ASME Component 4.

I Manuracturer.

_ I_

Serial NO. .

I

. NO.

_ _ I__

Idfl- clo Id n i ict o Bull, I

__I_

or Replaceffent (YesorNo)

PUMPICASING/ CRANE CHEM S/N: 19853-123 N/A ETN: OABOIPB 1975 REPLACED YES MOTOR ASSY CAT ID# 25768

__ ~~~ PUMP __  : _.__ _ 4 PUMP CRANE CHEM S/N: 0040714-1 N/A CAT ID# 1025670 2000 REPLACED YES CASING PUMP ETN: OABO IPB.

PUMP/MOTOR CRANE CHEM SIN: 2245280-1 N/A -: . . CAT ID# 1384325 2003 REPLACMENT YES ASSEMBLY PUMP . . ETN: OABOIPB ._. .

7. Description of Work REPLACE PUMP/CASING AND MOTOR ASSEMBLY - OABOlPB
8. Test Conducted: Hydrostatic' n Pneumatic .n Nominal Operating Pressure 'Z Other- n Pressure 13 0 psi Test Temp. ;2zvo -F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I1 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks WO000603188-03 -"

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date 20 0 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. , . have inspected t e components described in this Uwner's Report:

during the period 0/3v to , , and state that to the best of my knowledge and belief, the rwner has performed examinations and taker corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. C DateLS<~4i,2O ~3Commissions Date LW ,20 A

ElR-AA-330-009 l FILE:

. 3.11.1110 - Revision I Page 29 of 35 I I. I.

ATTACHMENT 4-FORM NIS-2 OWIkER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl Page I of 4

. . I I . . I

. 1. ' Owner . ' Exelon Nuclear ' '.' . .

- *'.Date .

9-27-03

  • Name.
  • 4300 Winfield Roao, Warrenville, IL Sheet .' 1 . of

': - ... . Address I.'I I

2. Plant  : Byron Nuclear Power Station .Unit 01

' Name. ..- *1I*

4450 N. German Church Road, Byron, IL 'Work Order No. 00508386- 01 Adidrefpqq Repair Orgar1izationi P.O. No., Job No., etc.

.3. Work Performed by N P S& W VENTURE ,Type Code Symbol Stamp 'Not Applicable Name. Authorization No. Not Applicable 555S. Joliet Rd, Bolingbrook, IL 60440 Expiration Date. Not Applicable ,

Address I . , . ..

Identification of System 'Co'mponent (.

5. (a) Applicable Constructidn Code Section III 1974. Edition, S74. Addenda, (*) Code.Case

.. '(b)Applicable Edition of Section' Utilized for,,Repairs 6r Replacement Cbmponents 19 89 (c) Section Xl Code- Cases used'- -

6. Identification of Components Repaired or Replaced and Replacement Components
  • . ASME . i.; . -- ...

Repaired, . Code National . Replaced,' Stamped Name of Name of Manufacturer Board Other' Year . or - (Yes or Component Manufacturer Serial No. -' No. Identification Built*. Replacement No).

Snubber PSA 7411 N/A ICC38012S - 1979 Replaced Yes Snubber. Usega 02615253/012 N/A 1CC38012S 2002. Replacement -No

7. Description of Work Replaced . n i
7. Description of Work Replaced PSA snubber with a Lisega snubber -. . ':
8. Test Conducted: Hydrostatic LI Pneumatic 3l Nominal Operating Pressure LI

. V173 *Other 3 Pressure psi Test Temp. .F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size Is 81/2 in. x 11 In., (2)

Information In items I through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

ER-AA-330-009 Revision 0 Cage 30 of 36 1

I.

ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 2 of 4

9. Remarks (*) 1644 Rev.7, 1651, 1682, 1683, 1685, 1686, 1728, 1729, 1734, N-108, N-180 Applicable Manufacturer's Data Reports to be attached WO# 00508386-01

. I

' CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Ap licable Signed n e t Date_5-20(03

.. 6;;~~~~~~rtr Ownees Designee, Trde , '

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period ak4/-103- to / , and state that to the best of my knowledge and belief, tfe Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

C;. Commissions /11-iZ6V Inspector's Signature National Board, State Province, and Endorsements Date: OVC, b , 20 03

FILE: f 3.11.11 10 ER-AA-330 009 Revision 1 Page, i9 of 35 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl Page Iof 4

. f, '..

_-- 'Date 9-26 .I

1. 'Owner ' .' Exelon Nuclear

. . I~~~~~~~

Name.  :

- _4300 Winfield Road, Warrenville, IL: ' - Sheet_.: 1 .of  :- 1 .

Address I 01 . I. .

2. Plant ' Byron Nuclear Power Station ':Unit

-~ 01 '

Name I.

4450 N. German Church Road, Byron, IL Work. Order No. 00508408 -01

. . 3 Address-, Repair Organization,. P.O. No.,-Job No., etc.

-3. Work Performed by N P S & W VENTURE Type Code Symbol Stamp . Not Applicable

--.ame, Authorization No. Not Applicable 555 S. Joliet Rd, Bolingbrook, IL 60440 Expiration Date Not Applicable Address ' . - -

4. Identification of System Component Cooi .. 'g
5. (a) Applicable Construction Code :Section III 19 74, Edition, S74 Addenda, () Code Case (b) Applicable Edition of Se 6tioneXI Utilized foriRepairs 6r Replacement Components 19 89 (c). Section Xl Code Cases used'.
6. Identification of Components Repaired or Replaced aid Replacement Components -

I

- , ~~~~~ASME Repaired, Code National Replaced; ' Stamped Name of Name of Manufacturer Board Other Year - or (Yes or Component Manufacturer Serial No. No. : - Identification Built, Replacement No)

Snubber PSA 9845 . N/A 1CC38019S 1980 Replaced Yes Snubber . Lisega 03615733/001 N/A 1CC3BO19S I. 2003; Replacement No

= ~~~~~~~~~I I= ________

=====-=.

7. Description of Work Replace failed PSA snubber with a Lisega snubber ' .
8. Test Conducted: Hydrostatic El Prneumatic.iE Nominal Operatingi Pressure a '

7VT3 Other E Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 81/2in.x 1I in., (2) information In Items I through 6 on this report is included on each sheet, and (3)each sheet Isnumbered and the number of sheets is recorded at the top of this form.

V ER-AA-330-009 Revision 0 PFage 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 2 of 4

9. Remarks (*) 1644 Rev.7, 1651, 1682, 1683, 1685, 1686, 1728, 1729, 1734, N-108, N-180 Applicable Manufacturer's Data Reports to be attached WO# 00508408-01 I

I

- ' CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the rules of the ASME Code, Section Xi. repair or replacement Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed . , Datesignee I I

. . . 3 ~~~~~~~Owner's Designee, Titie CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period to ________ ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Age - Commissions ///-

Inspector's Signature National Board, State Province, and Endorsements Date: E'c7/ 6 20 03

FILE: 3.11.1110 E!R-AA-330-009

- Revision I Page 29 of 35 ATTACHMENT 4  :.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl Page 1 of 4 1.- Owner . Exelon Nuclear Date 9-28-03 .I

-- -Name 4300 Winfield Road, Warrenville, IL Sheet 1 .of 1 Address

2. Plant.. Byron Nuclear Power Station Unit 01 Name 4450 N. German Church Road, Byron, IL
  • Work Order No; 00528268 - 01 Address Repair Organization, P.O. No.,-Job No., etc.
3. Work Performed by N P S & W VENTURE - ype Code Symbol Stamp Not Applicable T

Name Authorization No. Not Applicable 555 S. Joliet Rd, Bolingbrook, IL 60440 -Expiration Date Not Applicable Address 4.

. . Identification of System' omponeni olin

.. . (a) Applicable Construction Code Section li- 19 74_.Edition, S74 Addenda, (

  • Code Case

. 6.

  • (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89 (c)Section XI Code Cases used,'

Identification of Components Repaired or Replaced and Replacement Components ASME Repaired, Code National - Replaced,- Stamped Name of Name of Manufacturer Board . Other -Year -. or (Yesor Component Manufacturer Serial No. No. Identification - Built Replacement No)

Snubber PSA 1999 N/A I CC38011 S 1977 Replaced Yes Snubber . Lisega - 02615253/013 N/A 1CC3801 S  : 2002 Replacement No Relace degraded P.A snubber Snue .h . r.a

7. Description of Work Replaced degraded PSA snublber-with a Lisega Sniu-bber-
8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure El VTo Other E Pressure psi Test Temp.

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size Is 8Y in. x 11 in., (2) information in items 1through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.

ER-AA-330-009 Revision. 0 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page2of4 i

9. Remarks (*) 1644 Rev.7, 1651, 1682, 1683, 1685, 1686, 1728, 1729, 1734, N-108, N-180 Applicable Manufacturer's Data Reports to be attached Work Order No. 00528268 - 01 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the' rules of the ASME Code, Section Xl. repairor replacement Type Code Symbol Stamp- Not Applicable Certificate of Authorization No. Not Applicable Signed R A Date, 10-5 ,20 03 Owner Owners Designee, itle.'

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period God/>) 7o t/19t ,and state that to the best of my knowledge and belief, the 6 wner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Commissions Amp__ _ _ _ _ _ _

Inspector's Signature National Board, State Province, and Endorsements Date:

  • A,/ , 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT

'As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 9/29/03 Name 4300 Winfield Rd. Warrenville. D.60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 01

- . - . Name -

4450 N. German Church Road. Rvrn. 11. Work Request No. 99284784-01 Address . Repair Organization, P.O. No., Job No, etc.

3. Work Performed by Byron Mechanical Maintenance -Type Code Symbol Stamp Not Applicable
~. ' . Name -Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable Address
4. Identification of System Component Cooling [CC]
5. (a) Applicable Construction Code Section III 1971 Edition, W72 AddendaNONE Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

.ame .f .ame .f .anufacturer National . . Repaed. ASME

.Naneof Num of . MATInturr . board Other Replaced. Code-, Stamped comient Manufacturer Serial No. No. Idetification - Bulb or Replaceent -(Yes or No)

RELIEF VALVE CROSBY VALVE N57027-00-0018 N/A EPN ICC9428B 2000

. COMPANY REPLACED ^ YES RELIEF VALVE CROSBY VALVE N57027-00-0017 NIA EPN ICC9428B 1992

. COMPANY . . REPLACEMENT YES

7. Description of Work REPLACE RELIEF VALVE
8. Test Conducted: Hydrostatic E Pneumatic n Nominal Operating Pressure Other E0 Pressure 127 psi TestTemp. 86 OF Note: Supplemental sheets in-form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks Work Order 99284784-01 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. par rpla-ent Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date 11/,2 03 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components described in this Owner's Report during the period Z to , and state that to the best of my knowledge and belief, th&owtfer has performed examinations an take fcorrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Com missions / l / -/ 2 n'l e 20 s St ro . re Date D &c. 2 , 20 6t

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

- - . . i. Page I of 4

1. Owner Exelon Nuclear Date 10/22/91 see remarks page 2 Name 4300 Winfield Road, Warrenville, IL Sheet 1 cof 1

-Address

2. Plant Byron Nuclear Power Station - Unit 01 Name 4450 N. German' Church Road, Byron, IL Work Order No. B70777 Address -- Repair Organization, P.O. No., Job No., etc.
3. Work Performed by William A. Pope - - - - Type Code Symbol Stamp Not Applicable Company - JV Name Authorization No. Not Applicable 1024 Lunt Avenue, Schaumburg, IL 60193 Expiration Date Not Applicable Address
4. Identification of System Chemical and Volume Control (CV) 5., (a) Applicable Construction Code ASME Section III 1986 Edition, S/87Addenda, _ _Code'Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 83 S/83 (c) Section Xl Code Cases used, NONE
6. Identification of Components Repaired or Replaced and Replacement Components ASME

- Repaired, Code National Replaced, Stamped Name of Name of Manufacturer Board Other Year or (Yes or No)

Component Manufacturer Serial No. No. Identification Built Replacement 2"Globe Valve Kerotest AO-J2-10 NIA 1CV8382A 1989 Replaced Yes 2"Globe Valve KSB 190884/15 124 1CV8382A 1990 Replacement Yes

7. Description of Work Replaced valve per Work Order B70777 - see remarks page 2
8. - Test Conducted: Hydrostatic Z Pneumatic li . - .. Nominal Operating Pressure M Other Li Pressure': 2800 psi Test Temp. 70 OF Note: Supplemental sheets inform of lists, sketches, or drawings may be used, provided (1)size Is8Yz in.x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.

ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 2 of 4

9. Remarks Valve replacement was performed in 1991 per Work Order B70777. The incorrect serial number was identified on the original Work Order B70777 Form NIS-2. This error was identified during walkdown activities for Work Order 508177 and is documented on Exelon Condition Report 145419. This NIS-2 is included in Work Order 508177-01, which does not have any Section Xi repair or replacement activities.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conform to the rules of the ASME Code,Section XI. Repair or replacement Type Code Symbol Stamp Not Applicable Certificate ofAuthorization No. Not Applicable Signed Qi,) CA.Ut, Date lo -:z3 , 20 03 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of H rtf d, CT have inspected the components described in this Owner's Report during the period j>//t/'9/ to t& , and state that to the best of my knowledge and belief, the Otwner has performec'examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

9__________ _ Commissions /__- /_ _ _ _ _

Inspector's Signature National Board, State Province, and Endorsements Date: AW O4 20 0 3

a FORM NIS-2'OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 09130/03

- - . Nane 4300 Winfield Rd. Warrenville, II. 60555 Sheet I of I Addrws

'2. Plant Byron Nuclear Power Station Unit 01 4450 N. German Church Road, Byron, I1. - - Work Request No. 00422813-01 Address Repair Organization, P.O. No., Job No., etc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable
Nane. Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable Address 4.- Identification of System Chemical & Volume Control (CV)
5. (a) ApplicabieCo'nstructionCode SectionIII 19 71 Edition, W72 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

.at l .. ... Nepairod. ASME Nam of Name of . 'Mahrfacrxr boaed Other Year bPlaced, Code. Stamed Coqoni Marhft Seral No. No. Identification Built orRIilapement (Yes or No)

CHECK VALVE KEROTEST SIN NOI-16 9606 -CV8348 I -1976 REPLACEMENT YES (SEAL WELD) . . ._._. _._. _- _ _._. _._._._.

t0;1 13 1 a'. -L1: - 0 1 i= S 1 '~

7. Description of Work REMOVE AND REINSRALL COVER TO BODY SEAL WELD -1 CV8348
8. TestConducted: Hydrostatic [l Pneumatic n NominalOperatingPressure 0 l Other. 0 Pressure 2235 psi TestTemp. 617 ' F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet,'and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form bas been electroncally generated.

FORM NIS-2 (Back)

9. Remarks Work Order 00422813-01 Applicable manulacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. .lr rd Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date Vts ,20 3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the c mponents described in this Owner's Report during the period Z/05 to _mon , and state that to the best of my knowledge and belief, the Owner hits performed examinations anid taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connecteith this inspection.

Sigt-e 1.pecto7'. Coimmissions SI Date , 20 e95

FILE: 3.11.1110 ER-AA-330-009

- Revision 1 Paae

  • _w _- 29

__ of

_. 35.

-ATTACHMENT 4 --

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi' Page I of 4

1. Owner . Exelon Nuclear ' Date 9-26-03'

' Name. .. I .. . . .

4300 Winfield Roac, Warrenville, IL - Sheet . 1 .of 1

. . Address .,I7 . -.

. n . 01 .. . _.. .

. . 2. Plant Byron Nuclear Power Stati on ' ' Unit 01 Name Wdr.Order No. 00.020-01 I

-4450 N. German Church Road, Byron, IL Wdrly Order No. 00508380WO- 01 I

-- - ' ' . Address Repair-Organization, P.O. No., Job No.,.etc.

3. Work Performed by N P S & W VENTURE Type Code Symbol Stamp 'Not Applicable Name.: Authorization No. Not Applicable 555 S. Joliet Rd, Bolingbrook, IL 60440 Expiration Date Not Applicable, Address ' ., -  :.

A. Identification of System Chemical & Volme Conroyl

'5. '(a) Applicable Construction Code Section III . 19 74. Edition, S74 Addenda, -*) Code Case (b) Applicable Edition of Se6tional( Utilized forRepairs or Replacement Components 19 89

'(c). Section Xl Code Cases used-

6. Identification of Components Repaired or Replaced a nd Replacement Components I

. . ~~~~~~~ASME Repaired, Code National . Replaced, Stamped Name of Name of Manufacturer Board Other Year or (Yes or Component Manufacturer Serial No. No. ' Identification Built Replacement No) ¶ Snubber PSA 147876 N/A- ICV09005S. -1982 Replaced Yes Snubber Lisega 03615733/003 N/A 1CV09005S 2003 Replacement No

. ....  : . j .' .:= , ^ ,., .

. DI

7. Description of Workd Replaced PSA snubber with a Lisega snubber
8. Test Conducted; Hydrostatic f I Pneumatic . Nominal Operating Pressure a

. IT-3 Other Z Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 81/2 in. x 11 in., (2) information in Items I through 6 on this report is included on each sheet, and (3)each sheet Is numbered and the number' of sheets is recorded at the top of this form.

ER-AA-330-009 Revision 0 PFage 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 2 of 4

9. Remarks (*) 1644 Rev.7, 1651, 1682, 1683, 1685, 1686, 1728, 1729, 1734, N-108, N-180 Applicable Manufacturer's Data Reports to be attached WO# 00508380-01 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed if 28£ EJa Deayf zIo Date la 5- , 20 03 or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period 4O/3/O to , and state that to the best of my knowledge and belief, the Owner has perforn 'examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property dama e or a loss of any kind arising from or connected with this inspection.

___________________ _- Commissions ] 'Z-/l ?5' Inspector's Signature National Board, State Province, and Endorsements Date: of ,g , 20 03

ER-AA-330-009 Revision 1 Page 27 of 35 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT,'

As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 09/27/03

-- Namre

  • 4300 Winfield Rd. Warrenville, 11. 60555 Sheet I of ' _I Address
2. Plant Byron Nuclear Power Station Unit 01 I Natme 4450 N. German Church Road, Byron, II. Work Order No._526122-01 - -_ _

Address . Repair Organization. P.O. No., Job No., etc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Nanm Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. - - Expiration Date -Not Applicable _______

Address

4. Identification of System CV
5. (a) Applicable Construction Code Section III 19 71 Edition, W72 AddendaNO Code Case (b) Applicable Edition of Section XI Utilized for Repairs oirReplacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components
  • National Repaired. ASME -

Narre of Nameof Manufcturer Board

  • Other Year Code; Stumped Cornonent ' Manufacturer Serial No. .No. Identifteation Buik or Repacemnt (Yes or No)

,CHECK VALVE KEROTEST P.99 I 1 -l.{)Z 9605 ICV8368A 1976 REPLACEMENT YES BODY of SEAL WELD

7. Description of Work Replacement of seal weld to support maintenance
8. *TestConducted: Hydrostatic. QPneumatic [ Nominal Operating Pressure 0

-;3 7q Other C Pressured psi TestTemp- rl~6- OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

ER-AA-330-009 Revision 1 Page 27 of 35 FORM NIS-2 (Back)

9. Remarks: Replacement of body to bonnet seal weld to support maintenance per Work Order 526122-01, no valve parts were replaced.

Apphcabie Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. Meai, crIa Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed (D AA a. &w Date / 5 ,20 0 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period _3__ to ___ , and state that to the best of my knowledge and belief, the Owvnetr has performed examinations and taken'corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -m i

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Commissions ,/i -125$'t 4" inspIces Signzre Nacioaf oart SlareProvrnct.and Date AlY , 20 01?

-  :... ER-AA-330-009 Revision I Page 27 of 35 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT

-As Required by the Provisions of the ASME Code Section XI

.1. Owner Exelon Nuclear Date 10/29/03

. Nare 4300 Winfield Rd. Warrenville, 11. 60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 02 Namte 4450 N. German Church Road, Byron. 11. - Work Order No. 00560662-01 Address Repair Organization, P.O. No., Job No., etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable 4490 N. German Church Road, Byron, 11. Expiration Date' Not Applicable Add* ss
4. Identification of System CV - CHEMICAL AND VOLUME CONTROL
5. (a) Applicable Construction Code Section III 1971 Edition,W72 AddendaNONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components oatrodl Rftarub q ied ASME

,,Nrofr Namof ote° Year Con-. Sorvd

,qwLF ..j- I I _ _ - __ __ _ _ __ __ __ I Idendificaron I Bulk I oriteplcerment I (Yemor No)

BODY /COVER . KEROTEST *P-991 l!-l(1)Z 9976 2CV8480A 1976 REPLACEMENT YES SEAL WELD UP-9911.2(1)Z SIN: TB2-8

7. Description of Work SEAL WELD COVER TO BODY-I CV8480A

.8.

  • Test Conducted: Hydrostatic E Pneumatic Q Nominal Operating Pressure 3 Other Q Pressure 2500 psi Test Temp. 108 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been elctronically generated.

ER-AA-330-009 Revision I Page 27 of 35 FORM NIS-2 (Back)

9. Remarks Work Order 00560662-01 A.-i-lune Man-nfDcturer s LDa R-ranz to be anriched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. .a Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed SDAil ,, ts~sy-t so Date II 1/ ,20 0R CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components described in thus Uwner's Report during the period _ _ __ __ _ to za D , and state that to the best of my knowledge and belief, the Ofnerdias performed examinations and taken tofrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__________________________ Commissions g1/--Z/fLZ4f Date ) , 20 0

DOCUMENT NO.: 3 REV. NO.: 0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI -

1. Owner Exelon Nuclear Date 09/30/03

- Name 4300 Winfield Road, Warrenville, IL Sheet I of i Address

'2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Church Road. Byron. IL --Work Order No. 00599592-01 Address Repair Organization, P.O. No., Job No., etc.

3. Work Performed by N P S & W VENTURE Type Code Symbol Stamp . Not Applicable

Name Authorization-No' Not Applicable 555 S. Joliet Rd, Bolingbrook, IL 60440 -Expiration Date Not Applicable

-- - Address - - -

4. Identification of System CHEMICAL FEED & VOLUME CONTROL [CV1 AbMt Section il 196 Edaition, 87 Addenda (valve)7
5. (a) Applicable Construction Code ASME Section III 19 74 Edition, S75 Addenda, None Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89 (c)Section XI Code Cases used, N-416-1
6. Identification of Components Repaired or Replaced and Replacement Components ASME National . Repaired, Stamped Name of. Name of Manufacturer Board Other Year or Replacement (Yes or No)

Component Manufacturer Serial No. No. Identification - Built VALVE, GLOBE. KLEIN 190884/6 115 1CV8384B1 - 1990 Replaced. YES 2".1700# SCHANZ .  ; -- - -

VALVE, GLOBE KLEIN 190884112 121 1CV8384B 1990 Replacement YES 2". 1700# SCHANZ - .

PIPE SANDVIK HEATCODE NIA ICV13AB 1984 Replaced 2". SCH. 160 STEEL 469916  :. . NO PIPE HEAT CODE N/A 1CV13AB 2001 Replacement 2%, SCH. 160 ALTX, INC. 070037 - NO ELBOW, 90 DEG. Alloy Stainless HT: 74188 -- N/A 1CV13AB 1977 Replaced NO 2", 6000# Products Co.' Code: Pl ELBOW, 90 DEG. Alloy Stainless HT: 74188 N/A 1CV13AB 1977 Replacement NO 2" 6000# Products Co. Code: Pi . . - .

COUPLING, PIPE Camco Fittings HEAT CODE N/A ICV13AB -- 1981 Replacement NO 2". 6000# Co. EEX '

7. Description of Work REPLACE PIPING AND VALVE 1CV8384B
8. Test Conducted: Hydrostatic D Pneumatic E Nominal Operating Pressure ED Other E Prressure 2379 psi - Test Temp. 108 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8%In. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 (Back)

9. Remarks Work Order 00599592-01 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Not Applicable Certificate of A thorization No. Not Applicable Signed Date I (/g4 ,20 03

\4) ~~~~~Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, CT have inspected the components described in this Owner's Report during the period

.ZI/7/>5 to / -// , and state that to the best of my knowledge and belief, t e wner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_y__

_ __ _ _ _ _ _ .Commissions

_ _ _ _ _ _ ,'/ - /2*4 Inspectors Signature National Board, State Province, and Endorsements Date: /%,C. . , 20 03 (Final)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

'Page 1 of I

1. Owner Exelon Nuclear - - Date - -- 02/20/03 Name 4300 Winfield Rd. Warrenville, IL 60555 Sheet 1 of 1 Address
2. Plant Byron Nuclear Power Station Unit 01 Name - -

4450 N. German Chruch Rd. Byron, IL 61010 WO 00429782-02 Address *~.. Repair Organization P.O., Job No., etc

3. Work Performed By Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable 4450 N. German Chruch Rd. Byron, IL 61010 Authorization No. Not Applicable Address Expiration Date Not Applicable
4. Identification of System [DG] DIESEL GENERATOR [JW UPPER HX CLR]
5. (a) Applicable Construction Code Section III 19 74 Edition, S/75 Addenda, ____Case N/ACode (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 89 (c)Section XI code Cases used, N/A
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Year Repaired, Code Component Manufacturer Serial No. Board, Identification Built Replaced, or Stamped No. * ~~~~~~~Replacement (Yes or

. o. ~~~~~~~~~~No)

END CVR AMERICAN HX S/N:- N/A I DG01KA-X1 SIN; 1978 REPAIRED YES WEST STANDARD 9-20003-06-1 9-20003-06-18 OUTER oA0- i s CHANNEL AMERICAN HX S/N: N/A 1DG01KA-X1 SIN; 9 R HEAD STANDARD 9-20003-06-1 9-20003-06-1 197 REPAIRED YES FLANGE

. MACHINE REPAIR OF'UPPERJW HX CHANNEL HEAD AND END

7. Description of Work COVER
8. Test Conducted: Hydrostatic a Pneumatic nZ Nominal Operating Pressure Other E Pressure 8.0 psi Test Temp. 125 : OF 0

. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 112 in. x I1 In., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl Page 1 of 1 (Back)

9. Remarks WO# 00429782-02 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair conform to the repair or replacement rules of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed w RR Co Date ;/ag , 20 03

\<

U '-- -( n or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by H.S.B. CT.

of Hartford, CT. Hayi pected the components described in this Owner's Report during the period to / ,and state that to the best of my knowledge and belief, theO~ner has pe rf6rned examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

~~- _An gels _ Commissions H Iz - /ZSY'

-" -' -- ' Inspector's Signature National Board. State, Province, and Endorsements Date a ,20

,20 e:3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Page 1 of 1

1. Owner Exelon Nuclear Date 02/20/03
  • Name 4300 Winfield Rd. Warrenville, IL 60555 Sheet 1 of 1 Address
2. Plant Byron Nuclear Power Station Unit 01 Name

-4450 N. German Chruch Rd. Byron. IL 61010 - WO 00429782-06 Address Repair Organization P.O., Job No., etc

3. Work Performed By; I. Byron Mechanical Maintenance

' Type Code Symbol Stamp Not Applicable 4450 N. German Chruch Rd. Byron, IL 61010 Authorization No. Not Applicable Address Expiration Date Not Applicable

4. Identification of System [DGI DIESEL GENERATOR [JW LOWER HX CLR] --
5. (a) Applicable Construction Code Section III 19 74 Edition, S/75 Addenda, _N/ACode

_ _ ___ _ __ _ _ _ _ _ _ _ __ C ase (b) Applicable Edition of Section XI Utilized for-Repairs or Replacements 19 89 (c)Section XI code Cases used, N/A d6.e Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Year Repaired, dSme Component Manufacturer Serial No. Board Identification Built Replaced, or Stamped No. Replacement (Yes or

- > . ~~~~~~~~~~~~~~~~No)

West End American - HX S/N:

Cover Standard 9-20003-07-1 N/A iDGo1KA-X2 1976 Repaired YES Outer Floating American HX I/YES 1 N/A OGOI KA-X2 1978 Repaired Channell-Head Standard 9-'20003-07-1 _ _ _ _ _ _ _ _ _ _ ___ _ _ _ _ _ _ _

Nova Machine H odDJ 5/8 Nut (3) Products HT Code DJQ N/A - IDG01KA-X2 1999 Replaced NO

'Nova Machine Code VCF 5/8 Nut (3) Products-*

-HT HT Bod035 N/A 1DG01KA-X2 2000 Replacement NO Prouct B803 .H Machine Repair JW Cooler Channel Head & End Cover. Weld Repair 5

7. Description of Work. Locations on Channel Head Flange. Replace 3 Cover Bolting Nuts -
8. Test Conducted: Hydrostatic El Pneumatic - D Nominal Operating Pressure 09 Other Ea Pressure 8.0 psi Test Temp. 125 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Page 1 of I (Back)

9. Remarks Invoked Code Case N-416-1 WO# 00429782-06 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair Replacement

& conform to the repair or replacement rules of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed W Cad,/-. Date , 20 ok

\s yJ Op 9~r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by H.S.B. CT.

of Hartford, CT. Have i spected the components described in this Owner's Report during the period

//f Y 3/ to , and state that to the best of my knowledge and belief, thelbvwvier has perf6rm6d examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property dan age, r a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Com missions _ _ _ _ _ _-z__ _ _ _

Inspectors Signature National Board, State, Province, and Endorsements Date a ,,2020 e3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 05/13/03 Narne

- 4300 WVinfield Rd. Warrenville, 11. 60555 Sheet I of I Address

2. Plant Byron Nuclear Power Station Unit 01' Namne 4450 N. German'Church Road, Bvron, II. .Work Order No. 00469595-02 & -01 Address Repair Organization, P.O. No., Job No, etc.
3. Work Performed by Byron Mechanical Maintenance - Type Code Symbol Stamp Not Applicable Narne Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. (*) Expiration Date .-Not Applicable Address 4.. Identification of System [DGI DIESELGENERATOR
5. (a) Applicable Construction Code Section III 19 74 Edition, S/75 AddendaNO Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National Repaired. .ASME Nouneor Nane of. Manuacturer.r, Board ' Other year Replacod. Code;Starmped Corrrtponezu Manufacturer SerialNo. Ndensifeataion

' Built - or Replacement , (Yesor No)

END COVER AMERICAN HX S/N: ETN:IDGOIKB-XI REPAIR - NO WEST - - STANDARD 9-20003-06-2 32715 SIN: 9-20003.06.2 1978 . . .

END COVER AMERICAN HX S/N: . ETN:IDGOIKB-XI NO EAST STANDARD 9-20003406-2 32715 S/N: 9-20003-06-2 1978 REPAIR CHANNELHEAD AMERICAN HX SIN: . ETN:IDGOIKB-XI NO WEST . STANDARD .- 20003-06-2 32715 SIN: 9-200036-2 1978 REPLACED .

CHANNEL HEAD IONICS INCORP. FLTG CHANNEL N/A ETN:IDGOIKB-XI 2002 REPLACEMENT YES WEST . HD SIN:RP-2015 CHANNEL IONICS INCORP N FLTG HEAD UPPER FLTG CHANNEL HD S/N:RP-2015 N/A

. ETN:IDGOIKB-XI 2002 REPAIRED NO EAST CHANNEL AMERICAN HX SIN: ETN:IDGOIKB-Xi HD5/8- STUD (2) STANDARD 9-20003-06-2 32715  : SIN: 9-20003406-2 1978. REPLACED NO EAST CHANNEL NOVA MACHINE HT: 77091 N/A ETN:IDG01KB-XI 2001 REPLACEMENT. NO HD 5/8" STUD (2) PRODUCTS . SIN: 9-20003-062

7. Description of Work Repair East/West End Covers. Replace/Machine West Channel Head. Replace 2 Studs (#23/#24).
8. Test Conducted: Hydrostatic E Pneumatic El Nominal Operating Pressure s Other 0 Pressure 8.5 psi Test Temp. 163 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x I I in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks 00469595-02/01 Apphcabk Manufacturer's Dala Repons to beattached t

  • 9.

(*) East & West Lower End Covers were welded and machined by CFM/VR-Tesco, 1'875 Fox Lane, Elgin, IL 60123.

(Refer Purchase Order 00059140)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair & Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of uthorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed ( Rk Date J/3 , 2 0k3l CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. , have inspected the components described in this Owner's Report during the period 3 /tp, to g / , and state that to the best of my knowledge and belief, thd'Ovlner has performed examinations and takef corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manrter for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Q Z? aG 7~ Commissions ,LM5qV-

/ Inspetas Spsawu-la, Wi.e Date 4?i ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASIME Code Section XIl

]. ' Owner Exelon Nuclear Date 05/13/03 Name 4300 W\'infield Rd.'Warrenville, 1.60555 Sheet I of I Address

2. Plant Byron Nuclear Power Station Unit 01' Namec 4450 N. German Church Road, Bvron, 1. - Wnrk Order No. 00469595-06 Address Repair Organization P.O. No., Job No. etc.
3. Work Performed by Byron Mechanical M\intenance; Type Code Symbol Stamp Not Applicable Name Authorizati6n No. Not Applicable 4450 N. German Church Road, Byron, I1. (*) Expiration Date, Not Applicable Address
4. Identification of System EDGI DIESEL GENERATOR
5. (a) Applicable Construction Code Section II1 19 74 Edition, S/75 AddendaNO Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement. Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

. Othe, Year m. Repaired.

p.. ASME Narne of Nare of Manufactvrer Board Year Replaced. Code;Suimed Conponent Manufacturer Serial No. . No. Idemifleation Built or Replacenent (Yes or No)

END COVER AMERICAN.. HX S/N: ETN:IDGOIKB-X2 . REPAIR NO WEST STANDARD 9-20003-007-2; 32716 S/N: 9-20003-07-2  : 1978 END COVER AMERICAN HX S/N:

  • ETN:IDGOIKB-X2 .

EAST STANDARD 9-20003-007-2 32716 S/N: 9-20003407-2 1978 REPAIR NO CHANNELHEAD AMERICAN HX SIN: . ETN:IDGOIKB-X2 .

WEST . STANDARD 9-20003-007-2 32716 . SIN: 9-20003-07-2 1978 REPLACED NO CHANNEL HEAD IONICS INCORP. FLTG CHANNEL N/A ETN:IDGOIKB-X2 WEST HD M S/N:RP-2016 . . 2002 REPLACMENT- YES FLTG CHANNEL IONICS INCORP. FLTG CHANNEL N/A ETN:I DGO IKB-X2 HEAD LOWER HD M._________

S/N:RP-2016 2002 REPAIRED NO

7. Description of Work Machine/Weld Lower East & West End Covers. Replace &Machine Lower West Channel Head
8. Test Conducted: Hydrostatic El Pneumatic 0 Nominal Operating Pressure 3 Other n Pressure 8.5 psi Test Temp. 163 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number' of sheets is recorded at the top of this form.

This form has been electronicully generated.

FORM NIS-2 (Back)

9. Remarks WO# 00469595-06 II Applcable Manauacxurer s Data Repons to De attachfe

(*) East & West Lower End Covers were welded and machined by CFM/VR-Tesco, 1875 Fox Lane, Elgin, IL 60123.

(Refer Purchase Order 00059140)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair & Replacement conforms to the rules of the ASME Code,Section XI. repair aplanmea Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date 9 ,20 03 a s -Spnn.

- Ii CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period _________ to , and state that to the best of my knowledge and belief, the Owned has performed examinations and tak n corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for.any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____________________ Commissions ____________

Sqn r alional Br S-aleProvrnw,andLsdor.n- -Is Date ,20 693

r FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. ' Owner Exelon Nuclear' Date 05/10/03 Narne 4300 w'infield Rd. Warrens'ille, 1I. 60555 Sheet I of I Address
2. Plant Byron Nui1ear Power Station Unit 01' I . Narne 4450 N. German Church Road, Byron, II. ' 'WorkOrder No. 00469595-08 Address . Repair Organization, P.O. No., Job No., etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable II Narne Authorization No. Not Applicable 4450 N. German Church Road, Byron, n. Expiration Date,. -Not Applicable
  • - . ~~~~~~~~Address *.

4.. Identification of System FDGI DIESEL GENERATOR

5. (a) Applicable Construction Code Section III 1974 Edition,Sf75 AddendaNO Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

. . National Repaired. ASME Natneof nof Mantiufcnrerl'1 Board .' Other Year. , Replaced. Cod&Sumyed componem ManufacturerSi. , 1 No. dentification Built --

-orReplacement (Yes or No)

UPPER EAST AMERICAN HX SIN: . ETN:IDGOIK3B-X2 REPAIR NO CHANNEL HEAD STANDARD 9-20003-06-2 32715 SIN: 9-20003-07-2 1978 . . . .

7~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

7. Description of Work Machine/Weld Upper East Stationary Channel lead - IDGOIKB-XI
8. Test Conducted: Hydrostatic E Pneumatic El Nominal Operating Pressure 3 Other 0 Pressure 8.5 psi Test Temp. 163 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I1 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form hasbeen electronically generated.

FORM NIS-2 (Back)

9. Remarks WO$ 00469595-08 Applicabkl Manulaclurler S ata Kepons lObe attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair conforms to the rules of the ASME Code,Section XI. repairo replaceentn Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed A A Date ) ,20 O CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period to __ _ , and state that to the best of my knowledge and belief, the Ox~nerihas performed examinations and tak n corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for arry personal injury or property damage or a loss of any kind arising from or connected with this inspe tonCm so

__________________ Commissions________________

InspectorSignature Nalconal Board. Ste P-ovno. .nd Endorseets Date 4 ,20 0

II FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear -Date 05/08/03 -

Narr 4300 N'infield Rd. Warrenville, 11. 60555 Sheet I of I - I Address

2. Plant Byron Nuclear Powt er Station Unit 01' NarK 4450 N. German Church Road, Bvron, J.: ' Work Order No., 0039602 6-01 Address Repair Organization, P.O. No.. Job No., etc.
3. Work Performed by B)yron Mechanical Maintenance Type Code Symbol Stamp Not Applicable II .

Narn -Authorization No. Not Applicable 4450 N. German Church Road, Byron, Il. Expiration Date,' -Not Applicable Address

4. Identification of System [DOI DIESEL OIL
5. (a) Applicable Construction Code Section III 19 77 Edition, S177 AddendaN/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 .89.
6. Identification of Components Repaired or Replaced and Replacement Components Na meof .Na mecf ' .Nai.ol .R _A epaired. SM N I Name of ~ ~ a~,acre~lBordIother Yer- Replaced.CoeStm d C .=oera Manifacurr SerilNo. No. 8 ldrenircio, Buifl . oripep.,rmem (Yes or No)

RELIEF CROSBY. N62578-00-00I N/A ETN:IDO20B 1980 REPLACED YES VALVE VALVE: .____. _ -. ,__

RELIEF CROSBY N62578-00-00 N/A. ETN:IDO20B 1980 REPLACEMENT YES VALVE VALVE S .__._.._

A= = '."'. ,: " _ '.',. . _~~~~~'I

7. Description of Work REPLACE RELIEF VALVE WITH NEW BENCH TESTED RELIEF VALVE- I DO020B
8. Test Conducted: Hydrostatic n Pneumatic E Nominal Operating Pressure 3 Other E Pressure 23 psi Test Temp. Ambient OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This fonn has been electronically generated.

FORM NIS-2 (Back)

9. Remarks WO# 00396026-01 I

--.- ....-.. 11-..-------.--1-1 I

I CERTIFICATE OF COIMIPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. rpir Type Code Symbol' Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed IN, & Date ,20 03 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected thcomponents descnbed in this Owner's Report during the period to ,and state that to the best of my knowledge and belief, the Crxvr has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner fof any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Com m issions _ Z_-_ _ __ __

W. sq-y, N.-Moonboa0.-

. P0 ,

F--. *rai Lbndoisrirr Date e, 20 -05

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 02/19/03 Narne 4300 W\'infield Rd. Warrenville, IL 60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Church Road. Byron. II. Work Reauest No. 99244991-01 Address Repair Organization, P.O. No., Job No.. etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp None Name Authorization No. Not Applicable 4450 N. German Church Road. Bvron 11. Expiration Date Not Applicable Address
4. Identification of System Diesel Oil (DO)
5. (a) ApplicableConstructionCode Section ill 1977 Edition, S77 Addenda, none Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National Repared.- ASME Nameat Nameof Mauufacturer - board 'Other - Year Replaced, Code; Stamped Cor e Manufacourer Serial No. No. Idenlification Built or Replacement (Yet or No)

Relief Valve Crosby N6257800-0011 N/A IDO020A 1980 Replaced yes Relief Valve Crosby N62578-00-0009 N/A Cat ID 0000027081 1980 Replacement Yes

7. Description of Work: Bench test and replace relief valve
8. Test Conducted: Hydrostatic EJ Pneumatic D Nominal Operating Pressure s Other D Pressure 33 psi Test Temp. 81 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks Installation per Work Order 99A44991-01 ApplKable Manufacturer's Data Reporis to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. repaircrement Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Expiration Date Not Applicable Signed &cAfACA 0w-'s Deigwe. Tnk Date 3- ,20 03 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, Ct. , , have inspeced components described in this Owner's Report during the period ______ to Z/ , and state that to the best of my knowledge and belief, the'O,'ner has performed examinations and kel corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insir,-

this ~ Commissions_ _ _ _ _ _ _ _

npeni oro's Signature Nati-l Bard. Sate Prov-e andEndoetera Date 2W t .e, 20 63

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Exelon Nuclear Date -10/04103 -

Narne 4300 Winfield Rd. Warrenville, II. 60555 Sheet 1 of I Address

2. Plant Byron Nuclear Power Station Unit 01 Nare 4450 N. German Church Road, Byron, Il. Work Request- No. 00455752-01 Address.. Repair Organiization, P.O. No., Job No., etc
3. Work Performed by NWS Technologies, LLC Type Code Symbol Stamp Not Applicable Namre Authorization No. Not Applicable 131' Venture Blvd,. Spartanbure, . . SC 29306.

, Expiration Date Not Applicable Address

4. Identification of System MS MAIN STEAM (MS)
5. (a) Applicable Construction Code Section III 19 74 Edition, N/A AddendaN/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National Rtepaired. ASME N=nK OfNar of Manufiawter N siboard . Other Year Repaced. CodeRStarved Con. ontManufcturer Serial No. No. Identification Bult or Repcment (Yesor No)

DISC, VALVE DRESSER IND. GIE/AAF48 N/A IMS017A 1979 REPLACED NO VALVE ._._.: VIv S/N: BR09606 ._-_.

DISC, VALVE DRESSER IND. ADGI9 N/A IMS017A 2001 REPLACEMENT YES VALVE _______,___ Vlv S/N: BR09606

7. Description of Work REBUILD VALVE AT VENDOR - REPLACE VALVE DISC - IMS017A
8. Test Conducted: Hydrostatic El Pneumatic E Nominal Operating Pressure E N/A Other E Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

I FORM NIS-2 (Back)

9. Remarks SEE ATTACHED FORM NVR-1. WO#: 0045575-01 Applicable Manutacturer s Data Keportsto be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed 4 Date /7 , 20O2p3 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. have inspected the omponents described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the f)wndr has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Com missions Ad InspecTor'sSignaure

- s V Na.-ons bear4 Scat Provinu. and Lndotemenrs Date GodJ ,3 , 20 0

I

.I FORM NVR-1 REPORT OF, REPAIR pa - REPLACEMENT C

OF NUCLEAR PRESSURE RELIEF DEVICES, 95 16 8 I, .
  • iI I'~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

.1. Work performed by: NWS Technologies, LLC Purchase Order# 000642 Rev. I*

131 Venture Boulevard, .Spartranburg. SC 29#06 to 2; Work performed for Exelon Corporation, Byron Nuclear Station 3/4, Owner-.:name,.address and identification of nuclear power plant' Exelon Corporation, Byron Nuclear Station 4450 N: German Church Road Byron, IL 61010 5: a: Repaired pressure relief device: . Maln Steam Safety,,Valve b: Name of manufacturer. Consolidated I Dresser c: Identifying nos. ,s. .

3707R BR096O6. , nda .- steam 6" - 77 It

. ' (type) (mfr's SiN) (NB#) At'(service) (size) - (yr.bult) d: Construction Code: -ASME Section III 1974 I- dna n/a '

(name/sectionldivislon) ' . (edition ), (addenda) (Code Cases(s)) (Code C9ass)

6. ASME Code Section Xl applicable for inservice inspectioi:: I.:- 1989 n/a ri..

(edion) I I(addenda) (Cod! Case(s))

.I

7. ASME Code Section Xl used for repairs, replacements;- 1989 n/ad . rna
::uiC . - 1% . (edition) (addenda)

I (Code Case(s))

8. Constiuction Code used for repairs, replacemnents: 1974 n/a nia'-

(edition) (addenda) (Coce Case(s))

I: 1 : 1

9. Design responsibilities. n/a ,
  • . I .

1O.;.Opening pressure: .1,175 psig - .. _*

Or~~~~~~ ~~~~~

Set-pressure adjustmnnt made at NWS Technologies, LLC using steam

  • '~~~~~~I I , . .i
11. *Description of work (ndude name lnd idintying nurnbe ox replacdmerit parts): As-found steam test, disassembled,

.cleaned,Inspected, lapped nozzle, re ced disc, Iubljated as required. Certified set-pressue and seat

  • tUghtness using steam. I I

IL.

.~~~~~ MM~~~~

.Ime T1iIb-. O^-t uI~.b;II trq

^^1X'K~ U~SI-no ~iisie.Nvvo [aVe~I:F*1U0S*f.

ts I1tSe 11 CERTIFICATE OF-COMPLIANCE I, . Cesar V. Sierra certify that to-the best of my knowledge and belief the statements made I this:

report are correct and the repair, hnodification or replacemtn of thd pressure relief devices described above conforms to Section Xl of the ASME Code and the National Board Inspection Code 'VRW and "RW rules.

National Board Certificate of Authorization No. 632. to use the 'VR" stamp expires April 3, 2006.

National Board Certificate of Authorization No. 81' to use te "NRW stamp expires April 9, 2006.

C'1Z4'/03 NWS Technologies, LLC .Manager_ OA Date - Repair OrganizAtibn -.,A ,horlzed re, sentative itle-CERTIFICATE OF INSPECTION J, Charles F..Toegel Jr. holding a valid commission issued byThe National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina. and employed by Hartford Steam Boller of CT . of Hartford, CT have inspected the repair, modification or replacement described In this report on 9L374/° 3 and state that to the best of my knowledge and belief, this repair, modification or replacement has been dompleted in accordance with Section Xl of the of the ASME Code and the National Board Inspection Code NVR" and "NRW rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected W hisspe o

  • *§9 0t3 .. NB #8462, A, N,I NC# 1073 Dath . Ins e A Slgnatfre Cornnissions (NB (ind endorsements), jurisdicion,& no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner - Exelon Nuclear Date 10/04/03 Name 4300 Winfield Rd. -Warrenville, 11. 60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Church Road. Byron, 11. Work Request No. 00455755-01 Address . - ..Repair Organization, P.O. No.. Job No.; dc.
3. Work Performed by NWS Technologies LLC Type Code Symbol Stamp Not Applicable Name - Authorization No. Not Applicable -

131 Venture Blvd, Spatanbure, SC 29306 Expiration Date Not Applicable Address;

4. Identification of System MS MAIN STEAM
5. (a) Applicable Construction Code Section III 19 74 Edition, N/A AddendaN/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or'Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Notional Repsed. ASUIE NI1Dr of ' Ntre

' of - to -: . th er Year Replaced, Code;Staoped C.n t Manufacturer Serial No. No. Identification Built or Replacernent (Yes or No)

DISC, VALVE DRESSER IND. ADE41 N/A IMSOI6C 2001 REPLACED NO VALVE _ _ VIvS/N BR09604 ._;:

DISC, VALVE DRESSER IND. ADG 18 NIA IMS0 16C 2001 REPLACEMENT YES VALVE - -_. VIvS/N BR09604 ._._ .

7. Description of Work REBUILD VALVE AT VENDOR - REPLACE VALVE DISC - IMS016C
8. Test Conducted: Hydrostatic E Pneumatic E Nominal Operating Pressure E N/A Other El Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks SEE ATTACHED FORM NVR-I WO#: 00455755-01 Applicabie Manutacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. epair Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed s~~~~~~~~~~~~

> r Q AP\

.Cy Date o/_ ,20 V3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. have inspecte the omponents descnbed in this Owner's Report during the period  ;/J!4/0z7 to 'u2/Z 3/fe , and state that to the best of my knowledge and belief, theOwner has performed examinations and ten c rrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any mannerfor any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____s Commissions____________________________

Date DSRt5 ,20 3

I FORM NVR-1 REPORT OF IREPAIR t REPLACEMENT I OF NUCLEAR.PRESSURq RELIEF DEVICES -t1516 81ftq I

I I I ..

i. Work performed by: NWS.Technologles,.LLC Purchase C)rder# 00064290,Rev. I 131 Venture Boulevard, Spartanburg, SC 29306
2. Woik performed for. Exelon Corporation, Byron Nuclear Station 314. Owner - name,.address and Identification of nuclear power plant.' Exeloin Corporation, , . .

Byron Nuclear Station 4450 N. German Church Road Byron. IL61010

5. a: Repaired pressure relief device: Main Steam Safety Valve b: Name of manufacturer. Consolidated I Dresser I I I c: Identifying nbs.*

g %707R

  • *({type)

.BR09604 (mfes SIN)

  • nla ',

( ;N #)

steam (service)

-6 (size).

77 (yr.buit) d: Construction Code: ASME Section 1II: 1974 *n/a - hla - 2 -

(namelsectlonldiision) (edition).' (addenda) (Co( le Cases(s)) (*Code Class)

6. ASME Code Section Xi applicable for Inservice Inspection: 1989 '. . n/a ' ^

(edition) - (addenda) . (Code Case(s))

7. ASME Code Section Xl usedfor repairs, replacemenits, *I 1989 ,na'- n'a
  • . Construction for repbirsi Code used replacements (edition) (addenda) (Code Cases))
8. Construction Code used for repairs,, replacements: 1974 . n/a - n/a sedition) (addenda) (Code Case(s))
9. Design responsibilities: n/d A2 10. Opening pressture: 4190 psig
$et-pressure adjustment made at . NWS Technologies, LLC
  • using steam i11. Description of work indude name sandgenifying pu'tber freplacementparts): Disassembled.'inspected, Iapped, installed anti-vibration components, replaced compression screw-disc collar-spindel, machined spindle; replaced disc, lubricated as required. Certified set-pressure and seat tightness using steam. I

.. . . . . I

12. Remarks: New disc s/n ADGI8 installed. NWS *Traveler# 03-246.

CERTIFICATE OF COMPLIANCE..

1, Cesar V. Sierra certify that to the best of my knowledge and belief the statements made In this report are correct and the repair, modification or replacemtn of the pressure relief devices described above -

conforms to Section Xl of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

I National Board Certificate of Authorization No. . 632 to use the "VR" stamp expires April 3,2006.

National Poard Certificate of Authorization No. 81 to use thA W stam expires April 9,2006.

q/-34-.? Date.

NWS Technologies, LLC_/____naer W Manager. QA I Date -. - Repair Organization . idorkzed repre/ntative TItle

. CERTIFICATE OFINSPECTIO9 I, Charles F.Toegel Jr. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency Issued by the jurisdiction of North Carolina and employed by Hartford Steam Boller of CT .' of Hartford;CT have Inspected the repair, modification or replacement described in this report on .  ?/ Ea3 and state that to the best of my knowledge and belief, this repair, modification or replacement has betn cd pleted in accordance with Section Xl of the of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or Implied,'

concerning this repair, modification or replacement described In this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected t petio) 9/30/03_________________ _ .NB#8462, A, N,.I NC# 1073 Dite Inspecto MSIgn are Conmissions (NB (inc endorsements). Jurisdiction.& no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/04/03 -

Name 4300 Winfield Rd. Warrenville, 11. 60555 Sheet I of 1 Address

2. Plant Byron Nuclear Power Station Unit 01 Narm 4450 N. German Church Road, Byron, 11. Work Request No. 00511240-01 Address
  • 1. Repair Organization, P.O. No.. Job No. etc.
3. Work Performed by NWS Technologies LLC Type Code Symbol Stamp Not Applicable Nare Authorization No. Not Applicable 131 Venture Blvd, Spartanburg, SC 29306 Expiration Date Not Applicable
4. Identification of System MS MAIN STEAM
5. (a) Ajplicable Construction Code Section III 19 74. 'Edition, N/A AddendaN/A Code Case (b) Applicable Edition'of Section XI Utilized'for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National Repaired. ASME Name of Name of Manucturer -:board Yer dOther Code; Stamped Conmonent Mamraiturer Serial No No. identificason Built or Replacement (Yesor No)

DISC, VALVE DRESSER IND. GIEIAAF46 N/A EPN: 1977 REPLACED NO

. . VALVE ._ ._._._IMS017B DISC, VALVE DRESSER IND. ADG16 N/A EPN: 2001 REPLACEMENT YES VALVE. . . IMS017B

7. Description of Work REBUILD VALVE AT VENDOR - REPLACE VALVE DISC - IMS017B
8. Test Conducted: Hydrostatic n Pneumatic El Nominal Operating Pressure E N/A Other Q Pressure psi .Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been clctronically generated.

FORM NIS-2 (Back)

S 9. Remarks See Attached Form NVR-I. Work Request No. 00511240-01 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. reparorrwoboemen Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed C400sk Date JQ;1 ,2003 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. , - have inspected;'he components descn bed in this Owner's Report during the period i/V/03 to SOS' 3 , and state that to the best of my knowledge and belief, the4wn0r has performed examinations and takMn corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner forany personal injury or property damage or a loss of any kind arising from or connected with this ins ection.

__ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ C om missions

" - s S'p

/ / -/ Y Naional Bdward.

Z5 barePrSorn-c andEador-e.os Date //9, Z3 ,20 0 '

FORM NVR-1 REPORT OF REPAIR Da REPLACEMENT OF NUCLEAR PRESSURE RELIEF DEVICES %5.168 I.

, .1.Work performed by: NWS Technologies, LLC Purchase Order# _P0064250 Rev. I 131 Venture Boulevard, Spartanburg, SC 29306

2. Work performed for. Exelon Corporation, Byron Nuclear Station 314. Owner - name; address and identification of nuclear power plant , Exelon Corporation, Byron Nuclear Station 4450 N. German Church Road Byron, IL 61010 5, a: Repaired pressure relief device: Main Steam SofetWValve I

b: Name of manufacturer. Consolidated I Dresseir ---------- 7 b: Identifying nos. . . ' I

1. 707R BR096 07 ' nla steam '6 77i (mfWs SitN) * . (NBN) ' (service) (sizi 0), ..-_. (yrbuflt)
. . (narmelsectlon/divislon) (edition) ., (addenda) (Code Cases(s)) . (Code Class)
6. ASME Code Section XI applicable for Inservice Ins; 5ection: 19S9 , n/a n/a (editon) - (addenda) (Code Case(s))
7. ASME Code Section Xl'used for repairs, replaceme!nts: - 1989 nWa n/a (edition) (addenda) (Code Case(s))
8. Construction Code used for repairs, replacements: * ~~~1974 . nla n/a .

(edition) (addenda) (Code Case(s))

I ~ .

9. Design responsibilities: nla' . .

iO.'Opening pressure: 1175 psig Set-pressure adjustment made at ,NWSTechhologies, LLC using steam iI. bscription of work-(Incude name and Ftilng -nurnber df replacemen parts): Disassembled,,nskected, lapped,.'

  • 1  ;
  • installed ahti-vibration:corriponents, replaced compression screw-disc collar-spindel, machined spindle,.

replaced disc, lubricated as required) Certified set-pressure and seat tightness using steatn

12. Remarks: New disc s/n ADG16 installed. NWS Traveler#'03-248.

CERTIFICATE OF COMPLIANCE

- ~~CERTIFICATE OF COMPLIANCE *.

Cesar V. Sierra certify that to the best of my knowledge and belief the statements made In this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section Xi of the ASME Code and the National Board Inspection Code OUR" and "NR7 rules.

National Board Certificate of Authorization No. 632 to use the 'VR" stamp expires April 3, 2006.

Nat'onalBoard Certificate of Authorization No. 81 Jo use lIe "NR" stalp expires April 9, 2006.

Dale 9NWS Technologies; LLC Repair Organization

.horized iL*

rep ntative Manager, A Te CERTIFICATE OF INSPECTION 1, Chafies F.ToegeWr. holding a valid commission issued by The National Bpard of Boiler and Pressure Vessel Inspectors and certificate of competency issued by, the jurisdiction of North Carolina and employed by Hartford Steam Boller of CT . of Hartford, CT have Inspected the repair, modification I or replacement described in this report on QtI/oq and state that to the best of my knowledge and belief, this repair, modification or replacement has SeVen' dompleted in accordance with Section Xi of the of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned

-W.I nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected wthisspe t .

  • /No/03 IAP A NB 8462, A, N, I NC# 1073 1Dat' lns~elovsSigna re Commissions (NB _mcl endomerments), *urisdklor.8 no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/04/03 Name 4300 Winfield Rd. Warrenville, II. 60555 Sheet 1 of 1 Address
2. Plant Byron Nuclear Power Station Unit 01 Narne 4450 N. German Church Road, Byron, II. Work Request No. 541433-01 Address Repair Organization. P.O. No., Job No. etc.
3. Work Performed by NWS Technologies, LLC Type Code Symbol Stamp Not Applicable Narnb Authorization No. Not Applicable-

.131" Venture Blvd, Spartanburg, SC 29306 Expiration Date Not Applicable

  • Address- -D
4. Identification of System MS MAIN STEAM
5. (a) Applicable Construction Code Section III 19 74 Edition, N/A AddendaN/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

.National -Repaired. ASME Nanrof Nameof Manufacturer bo. Otbher Yea Replaced. Code; Steed Component Msnacturer Serial No. - No. - Identification Built or Replatrnent (Yes orNo}

DISC, VALVE DRESSER IND. AANOI N/A IMS017D X .- . 1981 REPLACED NO VALVE .. VlvSIN: BR09609 -_._._.

DISC, VALVE DRESSER IND. ADG40 N/A . I.IMS017D . 2001 REPLACEMENT YES VALVE -_._. . _ VIv SIN: BR09609 - -,

7. Description of Work REBUILD VALVE AT VENDOR -'REPLACE VALVE DISC - IMS017D
8. Test Conducted: Hydrostatic E Pneumatic El Nominal Operating Pressure D N/A Other E Pressure psi Test Temp. - OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This forn has been electronically generated.

FORM NIS-2 (Back)

9. Remarks SEE ATTACHED FORM NVR-I WO# 00541433-01 Applicable Manutacturcr s Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repmi-aftem Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Ud Date l e ,20 C'3 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. have inspected the components described in this Owner's Report during the period ?7/-3 A to _ _______ , and state that to the best of my knowledge and belief, the Own r has performed examfnatidris and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer-shall be liable in any manner for any personal injury or property damage or a loss of an kind aisi'g from or onnected with this inspection.

any_

j.'tnno ca r'siid.

_ _ _ _ _ _ __or_ _n Commissions - LL i

ZBr4te Addiu Date 62t1' o23 ,20 91

U .- 0 .

. iI l I II

  • FORM NVR-1 REPORT OF REPAIR REPLACEMENT 168; OF NUCLEAR PRESURE RELIEF DEVICES ,n  ;
1. Work performed by: NWS.Technologies, LLW P urchase Order# 00064250 Rev. 1 131 Venture Bulevard, Spartanburg, SC 29306
2. Work performed for. Exelon Corporation, Byron Nuclear Station I 314. Owner - name, address and identification of nuclear power plant . Exelon'Corporation, Byron Nuclear Station 4450 N. German Church Road Byron,'IL 61010
  • a: Repaired pressure relief'device: l.MainSteamSafetyValve . II b: Narne of manufacturer. Consolidated I Dresser . /;

I c: Identifying nos. ' .. , *,.I:

3707R BR09609 n/a ' steam 6N S. *. 77 (type) (mfis SoN) (NMw (service) Wn(skbe) . (yrebuift)

.s d: Construction Code: ASME Section Il. 1974 ,' nla nla .- _,211 (namelsection/divisn) (edon) n) l (addenda) (Code Cases(s)) - (Code Class)

6. ASME Code Section Xl'applicable for inservice Inspection 1989  ;; nla.1.

- . , , (edition) (addedda)" (Code Case(s))

7. ASME Code Section Xl used for repairs, replacements: 1989 nla - nla (edition) (addenda) (CodT Case(s))
8. ConstructionCodeusedforrepairs,replacements: ;974 3 ni . rla (edition) (addenda) ,'(Code Casecs))
  • 9. Design-responsibilities:, nla *. .5d .

'o0. Opening pressure: 1175 pslg ,.

Set-pressure adjustment made ;t t; .NWS Techqologles, LLC using

  • steam 11..- Description of work.(lridude'name a~nd Wns numnberof replacerhent par): Disassembled, cleaned, Inspected, lapped noizle, replaced disc,' lubricated as required: Certified set-pressue and seat tightness using steam.

. .. . ~~

12. Remarks: New disc s/n ADG40 Instalfed. NWS Traveler# 03-249.

-1.1 I 1, Cesar V. Sierra CERTIFICATE OF COMPLIANCE certify that to the best of my knowledge and belief the statements made In this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section Xl of the ASME Code and the National Board Inspection Code "VR" and "NRU rules. .,

National Board Certificate of Authorization No. 632' to use the WVR stamp expires April 3,2006.

NationalBoard Certificate of Authorization No. 81 to use tha NR sta p expires Apnr 9, 2006..

_________ *NWS Technologles,&LLC 'fg /I' Manager, QA Date Repair Organization A&Azednrep-t. Tite

- ~~~~~~~CERTIFICATE OF INSPECTION 1, CharlesF.Toegel Jr. holding a valid commission Issued byThe National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of. North Carolina and employed by Hartford Steam'Boller of CT of Hartford. CT have inspected the repair, modification or replacement described in this report on .530/o 2and state that to the best of my knowledge and belief, this repair, modification or replacement has been eompleted in accordance with Section Xi of the of the ASME Code and the National Board Inspection Code WYR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described In this report Futhermore; neither the undersigned.

nor. my employer.shall be liable in any manner for any-personal injury, property damage or loss of any kind arising from or connected it this insp ctio, ,2 . N C 1

.4, I.

!/D01 3Commisions (NB VW endorsements),jurisdiction.& no.)

JI-

. .11

.5~~~~~~~~~~~~~~~~~~~~~~~~~~~

~ I I ~~~~.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

. .. _ ..y

1. Owner Exelon Nuclear Date 10/04/03 Narric 4300 Winfield Rd. Warrenville, II. 60555 Sheet 1 of I

- -.- - - .Address

2. Plant Byron Nuclear Power Station Unit 01 Namne 4450 N. German Church Road, Byron, II. Work Request No. 00541434-01 Address - Repair Organization, P.O. No., Job No., etc.
3. Work Performed by NWS Technologies, LLC Type Code Symbol Stamp Not Applicable

- Name -Authorization No. Not Applicable 131 Venture Blvd,. Spartanbure, In . SC 29306 Expiration Date Not Applicable

.. Address -

4. Identification of System MS MAIN STEAM
5. (a) ApplicableConstructionCode SectionIll 19 74 Edition, N/A AddendaN/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National Repired. ASME Narmof Na&e of Manufacturer board - Other Year Replaced. Code;SanMed Component matufacrtue Serial No. No. Identification Built or Replacement (Yes or No)

DISC, VALVE DRESSER IND. GIE/AAF55 N/A - IMS016B 1977 REPLACED . NO VALVE . VLV SIN: BR09603 DISC, VALVE DRESSER IND. ADG20 NJA IMS016B 2001. REPLACEMENT YES VALVE - ._._:, _:_VLV SIN: BR09603

7. Description of Work REBUILD VALVE AT VENDOR - REPLACE VALVE DISC - lMS016B
8. Test Conducted: Hydrostatic E Pneumatic l Nominal Operating Pressure 0 N/A Other n Pressure psi Test Temp. `F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks See Attached Form NVR-l WO # 00541434-01 Apphr able Manutacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repi replacet Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Go StX Date /,20 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. the7 have inspected the components described in this Owner's Report during the period 5/05 to and state that to the best of my knowledge and belief, the Owner has performed examhatand taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employee shall be liable in any manner for any personal injury or property damage or a loss of anv kind arisin from o.connected with this inspection.

__ __ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Comm issions ,#n 54i Date f3 t S t20 t ad

ft 4.

  • .I.

FORM NVR-1 REPORT OQ REPAIR P REPLACEMENT Ci OF NUCLEARPRESSURE)RELIEF DEVICES 95 168

1. Work performed by: NWS Technologies, LLP. Purchase Order t 00064250 liev.I' '

131 Venture Boulevard, Spartanburg, SC, 29306

2. Wjprk performed for Exelon Corporation, Byron Nuclear Station 3/4. Owner - name, address and identification of nuclear power plant' Exelon Corporation, Byron Nuclear Station 4450 N. German'Church Road Byron, IL 61010

. I

5. a: Repaired pressure relief device: Main Steam Safety Valve I.

I -

. I b: Name of manufacturer; Cdnsolidated l-Dresser I -

c: Identifying nos. .*

  • '3707R
  • BRd9603* Vla , steam' ' ;6 _77 (type) . ** (mnfs S"N)* (Q;9#)- I (service) (size), (yrbut) d: Construction Code: ASME Section III , 1974 n/a _ Ila . . 2 (name/sedonldivislon) (ed tion),' (addenda) (Code l,ases(s)) (Cpde'6lass)
6. ASME Code Section Xi applicable for Inservice insl ,ection: 1989 nla nla dden a) . (Code Case(s))

.7. ASME Code Section Xl usedfor repairs, replacemE nts:, .1989 n/a.- ': nla .

(edfton) (aFddenda) (Code Case(s))

8. Construction Code used for repairs, replacements: 1974 .nia rnla addenda) (C66e Case(s))

. 9. Design responsibilities: n/a '

i 10. Opening pressure: .4`190 psig ' , '

Set-pressure adjustment made . WS Tchnologles, LIC Nat .. using steam U:- I -. . 1.1. Description' of work(lndude name and 0ehtit-yWngl rumbernof replaceEnt parts): Disassie ibled'cleaned, Inspected, IapDed nozzle, replaced disc. lubricated as required. Certified set-vressue and seat tightness using steam.

. Rmrs: , d . . I.  :

0 , 12. Rierarkcs: Niew disc sin ADG20 instAlled. NWS Traveler #'03.245.

Z"-

1l

. I,. .. :CERTIFICATE OF COMPLIANCE I; - .: Cesar V. Sierra' certify that to the best of my knowledge and belief the statements made In this report are correct and the repair, modification or repiacemtn of the pressure relief devices described above Lr-conforms to Section Xi of the ASME Code arid the National Board Inspection Code "VR" and "NR" rules.

National Board Certificate of Authorization No. .632: to use the 'VR"stamp expires April 3,2006.

Na onaJ Board Certificate of Authorization No. 81 to use t e "NR" stamp expires April 9, 2006.

9/5rl

. ate of NWS Technologies, LLC Repair OrgantiZon Am::Manager, Pjhortzed rerentative OA' Ttle..

CERTIFICATE OF INSPECTION 1, Charles F. Toegel Jr. holding a valid commission issued by.The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued. by the Jurisdiction, of North Carolina and employed by Hartford Steam Boller of CT ' of Hartford, CT have inspected the repair, modification' or replacement described in this report on 4 / and state that to the best of my knowledge and belief, this repair. modification or replacement has b3een cmpleted in accordance with Section Xi of the of the ASME Code and the National Board Inspection Code "MVR and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal Injury, property damage or loss of any kind arising from or connected issp NB# 8462, A, N, I NC# 1073

/Date A Insdoignzri Commissions (NB (ind endomemens). Jurisdktion.& no.)

0

- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/04/03 Narne 4300 Winfield Rd. Warrenvifle, IL 60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 01 Name -7.

4450 N. German Church Road, Byron, 11. Work Renuest No. 99120404-01 Address Repair Organization, P.O. No., Job No., etc.

3. Work Performed by NWS Technologies, LLC Type Code Symbol Stamp Not Applicable Name '-Authorization No. Not Applicable 131' Venture Blvd, Spartanburg, SC 29306 Expiration Date Not Applicable Address
4. Identification of System MAIN STEAM (MS)
5. (a) Applicable Construction Code Section III 1974 Edition,, NO Addenda, NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National . Repaired. ASME

-aNteof Naweof Mrmafeturer board Other Year Replaced, Code: Starped Comwonent Manathurer Seril No. No. Identifition . Buit or RepDemeiito (Yesor No)

VALVE DISC DRESSER AAM27 N/A. IMSO 14B 1980 . REPLACED . NO

. INDUSTRIES _ . VLV SIN: BR09595 . . . _._.

VALVE DISC. . DRESSER ADGI7 N/A IMSOI4B 2001 REPLACEMENT YES.

  • INDUSTRIES .- VLV SIN: BR09595 ____
7. Description of Work: REPLACE VALVE DISC WITH INCONEL X-750 MATERIAL DISC - 1MS014B
8. Test Conducted: Hydrostatic E Pneumatic a] Nominal Operating Pressure E NIA Other El Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks SEE ATTACHED FORM NVR-I WO # 99120404-01 0 9. Apphcable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. epair a ml.-rnt Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Expiration Date Not Applicable Signed Ad 0-job \e'.

Dnig-R Tole (tcr , Date /o/a. ,2007 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, Ct. have inspected the components described in this Owner's Report during the period to .'/ W; , and state that to the best of my knowledge and belief, the Owner has performed examinations and tafen corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Q/Z~~~

~~1~-7

~Commissions litapentC 4

s Signature

/ -

National 4 andEndarseretU Board.tareP-nrmre.

Date 3 ,20 r

I FORM NVR-1 REPORT OF REPAIR Ed REPLACEMENT 9g.

-I-,  !: .* OF NUCLEAR.PRESSURq RELIEF DEVICES . 95.16 8

= .

1. Work performed by: NWS Technologles, LlC Purchase Orders 00064250,Rev. 1 131 Venture Boulevard, Spartanburg. SC,29306 I 2. Work performed for Exelon Corporation, Byron' Nuclear Station 3/4. Owner - name, address and Identification of nuclear power plant, Exelon Corporation, Byron Nuclear Station 4450 N. German Church Road Byron, IL 6101 0 I

-4.*

5. a: Repaired pressure relief device: Main Steam Safety Valve b: Name of manufacturer Consolidated I Dresser c: Identifying nos.
  • 707R BR09595 ria *, steam *.6" _ _7 (type) (mfes SIN) (I'NB#) (service) (size) (yrtbuift)

I .

d: Construction Code: ASME Section IlIl 1974

  • nla I/a 2 (namelsectionr/diison) (edition). (addenda) (Code f ,eses(s)) (CC! !ss) .- ;
6. ASME Code Section Xi applicable for Inservice inspection: 1989 ._ n/a _ n_ _  :

I (edition) * (a7dde-ida) . (Code Case(s))

7. ASME Code Section Xl used for repairs, replacements- 1989 . n/a */ rta (edition) .. (aiddenda) (Code Case(s))
8. Construction Code used for repairs, replacements:, 1974 _ *n/a ' ,na.  :
  • Sedition) (aaddenda) (Code Case(s))

- I

9. Design responsibilities: n/a . . ' .

.. t4 10. Opening pressure: 1220 psig . .

Set-pressure adjustment made at . .NWS Technologles, LIC * .using steam,

1. Description of work (include name andd ent~iyngpurmber & replaement pats): Disassembled,'cleaned,inspected,

~ I  ; lapped nozzle, replaced disc, lubricated as required. Certified set-pressue and seat tightness using steam.

12. Remarks: New disc sin ADG17 Installed. NWS Traveler# 03-244. .

-.CERTIFICATE OF COMPLIANCE i.. . 1, .. Cesar V. Sierra' certify that to the best'of my knowledge and belief the statements made In this report are correct and the repair, modification or replacemtn of the pressure relief devices describedabove conforms to Section XI of the ASME Code and the National Board Inspection Code 'VR" and "NR" rules.

National Board Certificate of Authorization No. 632 ' to use the WVR" stamp expires Apnl.3, 2006.

National oard Certificate of Authorization No. 8 to usehe "NR" stmp expires April 9,2006.

9 03 NWS Technologies, LLC . 44 ' Manager, QA I

q,'~ 4 Data ~~Repair Organization. *1 iiredet~e toi pesnaieTo i

~CERTIFICATE OF INSPECTION r i I,. Charles F. Toegel Jr. holding a valid commission.issued by The National Board of Boiler and Pressure

!.t*

. Vessel Inspectors and certificate .of competency Issued by the jurisdiction of North Carolina and employed

';by Hartford Steam Boller of CT . . of Hartford, CT *have inspected the repair, modification t - ..'.II  :?or replacement described-in this report on q/1/9 o and state that to the best of my knowledge and belief, t.#..thls repair, modification or replacement has. beeh.cofnpleted In accordance with Section Xl of the of the ASME kCode and the National Board Inspection Code 'VReand 'NR' rules.

tufiy slgnlng this certificate, neither the undersigned nor my employer makes any warranty, expressed or Implied,

. J.

Aconcernlng this repair, modification or replacement described In this report. Futhermore, neither the'undersigned onor my employer shall.be liable In.any manner for any personal injury, property damage or loss of any kind ae1lng from or connected y this Inspc on. g-YI ,264XW L A p;s a NBI# 8462, A, N, I NC# 1073 1~ 467 Infp=1&*o:4r s7sn aIure Commissions (NB (mnd endorsements). Jurisdiction. no.).

CwAt.t.- -

.4'..>

4..

.4

- FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/04/03

.Name PO Box 805379, Chicago, II. 60680-5379 Sheet I ' of I Address

2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Church Road, Byron; II. - Work Request: 99179889-01 __ __-

Address Repair Orpnization, P.O. No. Job No, em

3. *WorkPerformed by nws Technologies LLC Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable 131 Venture Blvd, Spartanburg SC 29306 Expiration Date Not Applicable Address
4. Identification of System MAIN STEAM
5. (a) ApplicableConstruction Code'Section III 19 74 Edition, NO AddendaNONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

.~4= or, New of Naional Repaied. ASME Nameer NManuzfactur . Mboard . Othr Yewr Relaced. Code.Stan-Vd Cowponent Manufacurer SarialNo. No. Identification Built or Replacemen (Yes or No)

VALVE DISC DRESSER G/EIAAF49 N/A IMS013C - - 1977 REPLACED NO

. _INDUSTRIES ._._._._.: VLV SIN: BR09592 . _ _

VALVE DISC Dresser Industries ADG13 N/A IMSOI3C . 2001 Replacement YES VLV S/N: BR09592

7. Description of Work REFURBISH VALVE, REPLACE DISC - IMS013C 8.- Test Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure D N/A Other a Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks SEE ATTACHED FORM NVR-I WO# 99179889-01 Applicable Mantiacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. eps Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed RK r Date l/oZZ ,20Q3 nj- )er -6eD ice, Ta1.I-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. I.&I. Co.

of Hartford, CT. have inspected the omponents descnbed in this Owner's Report during the period 2o ,7 to __________ , and state that to the best of my knowledge and belief, the Owrlr has performed examinations afnd taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ C omm issions , is Date ___ _ _3 , 20 er')

FORM NVR-1 REPORT OF REPAIR C REPLACEMENT OF NUCLEAR PRESSURE RELIEF DEVICES ' 95 168 I

I .-Work performed by: NWS Technologies, LLC' .. Purchase Order# 0006425Q Rev. i ' #

.131 Venture Boulevard, Spartanburg, SC 29306 -

2. Work performed for. Exelon Corporation, Byron Nucidar Station 314. Ovener - jame, address and identification of nuclear power plant Exelorl Corporation,'

Byron Nuclear Station 4450 N. German Church Road Byron, ILGI1l1 5.* a: Repaired pressure relief device: Main Steam Safety Valve b: Name of manufacturer Consolidated / Dresser c: Identifying nop.

  • 3707R BR09592 nrna steam  ; 6"i 77 (type) (mns S *N) (NB#) . ,(service) (siz e) (yr.built) d: Construction Code: ASME Section III 1974 n/a' n/a (namelsectlonldivislon) (edition) (addenda) . (Code Cases(s)) (Code Class)
6. ASMIE Code Section Xl applicable for Inservice Inspection: I 1989 rna nig (ed.iyon) (addenda) (Code Case(s))
7. ASME Code Section X Iused'for repairs, replacements: 1989 ,, n/a " ri/a (odition) - (addenda) - (Code Case(s))
8. Construction Code used for repairs, replacements: 1974 *n/a n/a. .*

I (edition) (addenda) (Code Cases)) -i

9. Design responsibilities:. n/a ' . .
10. Opening pressure: 1235 psig '

Set-presslure adjustment made at . NWS Technologies, LLC using steam' .

.'11. I'description of work (nclude name and Identng number of replacemeht~padts): *As-found-test, bfisassembied, inspected, .

lapped, installed anti-vibration components, replaced Compression screw, disc collar, niachined spindle.

replaced disc; lubricated as required. Certified set-pressure and seat tightness using steam.

12. Remarks: New disc sin ADG13 installed. NWS Traveler# 03-242. . I CERTIFICATE OF COMPLIANCE .

1, *- CesarV. Sierra . certify that to the best of my knowledge and belief the statements made In this report are correct and the repair, modification or replacemtn of the pressure relief devices described above' conforms to Section Xl of the ASME Code and the National Board Inspection Code 'VR" and 'NR7 rules.

National Board Certificate of Authorization No. 632 'to use the `VR" stamp expires April 3, 2006.

Na ion Board Certificate of Authorization No. 81 ' to use N,"sp expires AVIn S. 2006.

NWS Technologles, LLC Manager,-QA Date Repair Organlxaiop ,.thozed rep7genlative Tale CERTIFICATE OF INSPECTION - -

.1, Charles F. Toegel Jr. holding a valid commission Issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency Issued by the jurisdidtion of North Carolina and employed by Hartford Steam Boller of CT . . of Hartford, CT have Inspected the repair, modification or replacement described in this report on. 9 /qn~cand state that to the best of my knowledge and belief, this repair, modification or replacement has bten eompleted in accordance with Section Xi of the of the ASME Code and the National Board inspection Code 'VR" and "NRW rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or Implied, concerning this repair, modification or replacement described In this report Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal Injury, property damage or loss of any kind arising from or connected wt this sp ctin.

Ni3OI I <SAXL K _ NB#8462, A,NI NC#1073 Dafe

  • In Commissions (NB (ind endorsements). Jurisdicion,& no.)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/04/03 Name 4300 Winfield Rd. Warrenville. IL 60555 Sheet I of I Address -
2. Plant Byron Nuclear Power Station Unit 01
  • . . Name 4450 N. German Church Road. Byron, 11. Work Request No. 99225979-01 Address Repair Organization, P.O. No.. Job No.. etc.
3. Work Performed by NWS Technologies, LLC - Type Code Symbol Stamp Not Applicable

.1. . I Name Authorization No. Not Applicable -

131 Venture Blvd, Spirtanburg, SC 29306 Expiration Date Not Applicable Address

4. Identification of System MAIN STEAM (MS)
5. (a) Applicable Construction Code Section III 1974 Edition, NO Addenda, NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

] Natiooal J(Maird. ASME Name of Nane of Manfacturer board Other Year Repace4 Code; Stanhed Coreyonent Manufeaurer Serial No. - No. idenifictio Bulk or leeplacemnew (Yes or No)

VALVE DISC DRESSER - G/E/AAF58 N/A IMS014A 1977 REPLACED, NO INDUSTRIES . . _._. ____VLVS/N: BR09594 ... _..._._-

VALVE DISC DRESSER ADG21 N/A IMS014A - 2001 REPLACEMENT YES INDUSTRIES ._ .. -VLVSIN: BR09594 ._ .

7. Description of Work: REPLACE VALVE DISC WITH INCONEL X-750 MATERIAL DISC- lMS014A
8. Test Conducted: Hydrostatic 5 Pneumatic n NominalOperatingPressure 0]

N/A Other EJ Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This forrn has been ekctronicafly generated.

FORM NIS-2 (Back)

9. Remarks SEE ATTACHED FORM NVR-I WO # 99225979-01 Applicable Manufacturers Data Repons to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. tepairareptmeat Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Expiration Date Not Applicable Signed 451 7 t Owners ile Designee, C Date IJo/Z ,20273 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, Ct. have inspected the components described in this Owner's Report during the period _ I os to _ _ _ _ _ , and state that to the best of my knowledge and belief, the Owner has performed examinations and take1i corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

1 1laPeor's Siga

_ _ _ _ _ _ _ _ _ _ _ _ o i oa /iZLESCommissions

-acid lz Natna Bard. SIMtePa m d Eadan "et Date3 , 20 103

.0 FORM NVR-1 REPORT OF REPAIR E REPLACEMENT 1 OF NUCLEAR PRE$SURE1REilEF DEVICES 95168 I

1. Work performed by: NWS Technologies, LLC Purchase Order# 00064250 Rev.1 131 Venture Boulevard, Spdrtanburg, SC 29306
2. Work performed for. Exelon Corporation, Byron Nuclear Station 3/4. Owner.- name, address and identification of nuclear power plant;' Exelon Corporation,

-Byron Nuclear Station 4450 N.German Church Road Byron, IL 61010 .

5. a: Repaired pressure relief device: Mairf Steam Safety Valve b: Name of manufacturer. C6nsolidated I Dresser . .0

.-1anifuinn# nnce * .  : -

  • I I U lfUl$llas sk Iiv nj;. . , - .

3707R . *BRO9594 n/a Adst earn .6 . - 77 (type) *(mfr`s SIN) . (NBM " (Seirvie) (size),' .. rbult-d: Construction Code: ASME Section III 1974 n/a rri/a . - 2g (namelsection/divislon) (edition)I (addends) (CideI Cases(s)) . C6de C3ss)

6. ASME Code Section XI applicable for inservice inspection: '
  • 1989 n/a -. nta

.19I89 I .~~~~~~~~~

(editkon) Is (a1 iddewvia) (Code Case(s))

l7. ASME Code Section XI used for repairs, replacements: I n/a n/a I. . I .' (edition) iddenda) (Code Case(s))

I . 8. Construction Code usdefor repairs, replacements: 1974 h/a

  • Dn/a

.. I

@ . (edition) . (9kddenda) * , (cdde Case(s))

.9. Design responsibilities: n/a 1O0. opening pressure:. 1220 psig . A. **

Set.pressure adjustment made t NWS Technologies: LLC

  • using steam i11. Description of work nd iirulngmber of rvapiemeht parts):

nam anndde Ditassembled,.deaned Inspected

.lapped nozzle, replaced disc; lubricatd as required Certified set-piessue and seat tightness using steam. .

I' 12.. Remarks: New disc sEn ADG2Instal N . .

I I

FERTIFICATE OF COMPLIANCE 1, CesarV. Sierra . certify th'atto the best of my knowledge and belief the statements made In this" report are correct and the repair, modification or replacemtn of the' pressiure relief devices described above conforms to Section Xl of the ASME Code and the National Board Inspection Code 'VR7 and "NR7 rules.

National Board Certificate of Authorization No. 632 to use the "VR" stamp expires April 3, 2006.

NationalBoard Certificate of Authorization No. 81i to uset HNR stamp expires April 9, 2006.

9/30/#3 NWS Technologies, LLC *Manager, QA Repair Organization

  • ored repsentative . Title CERTIFICATE OF INSPECTION I, Charles F. Toegel Jr. holding a valid commission Issued by.The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the Jurisdiction of North Caroling and employed by Hartford Steam Bollet of CT
  • of Hartford. CT :have inspected the repair, modification 4/LO 3 ' and state that to the best of my knowledge and belief, or replacement described in this report on this repair, modification or replacement has bein completed In accordance with Section XI of the of the ASME Code and the National BoardInspection Code "VR"and 'NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or Implied, concerning this repair, modification or replacement described in this report Futhermore, neither.the undersigned nor my employer shall be liable In any manner for any personal injury, property damage-or loss of any kind arising from or connected i thi Inspcyin.

L7LT2 9 NB # 8462, A, N, I NC# 1073

~ / H spedeur Commissions (NB (ind endorsements). Jurisdiction,& no.)

ER-AA-330-009 Revision I Page 27 of 35 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/12/03 Name 4300 Winfield Rd. Warrenville, II. 60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station -Unit 01 Name 4450 N. German Church Road. Byron. 11. Work Order No. 619665-01 Address . . Repair Organization, P.O. No., Job No., etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. -Expiration Date Not Applicable Address
4. Identification of System RC - REACTOR COOLANT
5. (a) Applicable Construction Code Section III 1974 Edition,S75 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 1989
6. Ieti.aio fCopnnt eaie r e1ce n Rpaemn omoet
6. Identification of Components Repaired or Rep-laced and Replacement Components National Repzired. ASME Narmeof Nane of Manufacturer Board Other Year Replaced, Code Starped cmornent Manufacturer Serial No. - No. - _ Identification Built or Replaceme (Yes or No)

BOLTS HUNTER CORP HT #LICG NIA S-RC-001-17 1984 REPLACED NO

______ _-__. MJ #2 ONUTS HUNTER CORP HT#LIBM N/A S-RC-001-17 1984 REPLACED NO

. __ ._..__._._. MJ #2 .

STUDS Cardinal Industrial HT# 61067 N/A CAT ID #40671 - 1991 REPLACEMENT NO Products _ ._._._._.

.UTSTS Korea Bolt Ind. HT# ID N/A - CAT ID #22615 1989 REPLACEMENT NO Co, LTD

7. Description of Work Replacement of flange studs and nuts
8. Test Conducted: Hydrostatic El Pneumatic 0 Nominal Operating Pressure E V/T-I oF 5ruos AddQO ,sii-SOther s Pressure n/a psi Test Temp. n/a F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

ER-AA-330-009 Revision I Page 27 of 35 FORM NIS-2 (Back)

9. Remarks: Replacement of flange studs and nuts per work order 619665-01. VT-I of studs and nuts per ASME Section XI Table IWB 2500-1 examination category B-G-2, pressure retaining bolting 2" and less. VT-2 not required per code interpretation XI-1-98-03.

Applicable Manufacturer's Data Reports to beattached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. reirorrclmnt Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed i Date /o - Jo ,20 £23 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period 3 to e/ /g zo 4t , and state that to the best of my knowledge and belief, theOwneir has performed examinations and tak n co rective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins ectiCn.

Date ~Commissions ,Z_

~ lll~ocio'Psm Sqgnur No-1naB3-d9 N.,v -rusd norl lDate O 2.<0 ,20 07

ER-AA-330-009 Revision I Page 27 of 35 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/09/03 Name 4300 Winfield Rd. Warrenville, II. 60555 Sheet I of I Address
2. ' Plant Byron Nuclear Power Station Unit 01

. Narne 4450 N. German Church Road, Byron, II. Work Order No. 00622075-01/03 Address Repair Organization. P.O. No., Job No., tc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Nane - Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable

-Address'

4. Identification of System 'REACTOR COOLANT
5. (a) Applicable Construction Code Section III 19 74 Edition, S/74 AddendaN/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National . .Reped. ASME Nu of. N areef mafacturer Board Other Year Replaced. Code-, staraed Comnentufacam Serial No. No. - Identification Built or Replacemnt (Ye or No)

Ambe Oil Cooler Perfex 875201-1 5721 IRC0lPD-M 1974 Replaced No B olts . . .. _.._._._._._. _

Ambe Oil Cooler Nova Machine HT# 7404456 N/A - IRC0IPD-M 2002 Replacement No

.0 Bolts Products Code: F469 . .. ._.._ ..

,Lbe Oil Cooler Perfex 875201-1 5721 IRCOIPD-M Replaced . No Nuts . . 1974 . .

jLube Oil Cooler Nova HT# B87035 N/A.. IRC01PD-M 2002 Replacement No Nuts Code: F390 _

7. Description of Work Replace ID RCP Lube Oil Cooler Bolting '
8. Test Conducted: Hydrostatic E Pneumatic El Nominal Operating Pressure El
  • N/A Other n Pressure_ psi Test Temp. 'OF Note: Supplemental sheets in form of lists, sketches, or drawings may be'used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This fbrm has been electronically generated.

ER-AA-330-009 Revision I Page 27 of 35 FORM NIS-2 (Back)

9. Remarks WO# 00622075-01/03 Appi~cable manuracturer S Dam Kqpor!sto Deallacnca CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. rpc Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed A 5 ok Ad Date 1D/I7 ,20 M CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the c mponents descnbed in this Owner's Report during the period to __________ , and state that to the best of my knowledge and belief, the Ow'ne? has performed examinations and takerf corfective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

_ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ C om missions /J l - /Zc f Date' Siv

,r..2d 0 Nai-nJ Board.Se.° .

Date OtO , 20 4r)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions I! .

of the ASME Code Section XI

1. Owner Exelon Nuclear Date 09/28103 Name 4300 Winfield Rd.'Warrenville, IL 60555 - Sheet 1- of 1 Address
2. Plant Byron Nuclear Power Station Unit 01

-Name -

4450 N. German Chruch Rd.' Byron, IL 61010 -

00422647-01 Address Repair Organization P.O., Job No., etc.

3. Work Performed By Byron- Mechanical Maintenar ice Type Code Symbol Stamp Not Applicable 4450 N.German Chruch Rd. Byron, IL 61010 Authorization No. Not Applicable Address Expiration Date ' :- Not Applicable,
4. Identification of System RESIDUAL HEAT REMOVAL [RH]
5. (a) Applicable Construction Code Section III 19 71 Edition, S72Addenda, NA CodeCase (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1.9 89 (c) Section Xl code Cases used, NA 6.' Identification of Components Repaired or Replaced and Replacement Components-ASME Name of Name of Manufacturer National Other - Year Repaired, Code Component Manufacturer Serial No. Board -Identification Built Replaced, or Stamped No..Replacement (Yes or Relief Valve Crosby N56904 NA 1RH8708B 1975 - Replaced: Yes Relief.__

Valve Crosby ' N 0018 001 __

NA _

1RH8708B 1975 _.,Replacement. _ Yes

7. Description of Work Relief Valve replacement
8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure 0.

Other Ea Pressure - 28 psi Test Temp. 82 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 1 (Back)

9. Remarks WO 00422647-01 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the repair or replacement rules of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed

\j_

-ThCc; 4A~

'--Kw_'iireor Owner's Designee. Title Date iVt , 20 0-3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by H.S.B. CT.

of Hartford, CT. Have inspected the components described in this Owner's Report during the period to L0*/ ,and state that to the best of my knowledge and belief, theOw~ner has perfofme'd examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________________________ Commissions god /ZS1r V", lnspecfor's Signature National Board. State. Province, and Endorsements Date {/ M i7*,& , 20 0~3

.Mtl;.lzS 4 W-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS' As Required by the Provisions of the ASME Code Section Xi Page I I 7 ~~._ ,

1. Owner Exelon Nuclear Date 09/30/03 Name

. 4300 Winfield Rd. Warrenville, IL 60555 - Sheet 1 *of 1.

Address

2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Chruch Rd. Byron,'IL 61010 I ' WO 00620168-01 '

Address Repair Organization P.O., Job No., etc

3. Work Performed By Byron Mechanical Maintenance

.Type Code Symbol Stamp Not Applicable 4450 N. German Chruch Rd. Byron, IL 61010 Authorization No. Not Applicable

- Address - Expiration Date '- Not Applicable

4. Identification of System RESIDUAL HEAT REMOVAL [RH]_
5. (a) Applicable Construction Code 'Section III 19 71 Edition;-S72Addenda, NA Code Case-(b) 'Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 -

(c) Section Xl code Cases used, NA  :

6. Identification of Components Repaired or Replaced and Replacement Components ASME~

Name of Name of Manufacturer National Other Year Rpaied, Co Component Manufacturer Serial No. Board Identification BuiltReplacednorSta Replacement- (Yes or

  • ~~~No.- -

Relief Valve Crosby - N56904 NA -1RH8708A 1975 Replaced ' Yes Relief Valve Crosby N56904 NA 1RH8708A 1975 Replacement Yes' 0 . N .p.cem..

7. Description of Work Relief Valve replacement .. - --
8. Test Conducted: Hydrostatic El Pneumatic [] Nominal Operating Pressure 0 Other [E Pressure 23 psi Test Temp. 82 OF 0

. NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in. x I1 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 1 (Back)

9. Remarks WO 00620168-01 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conform to the repair or replacement rules of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed V (2oeipr Owner's Designee, Title Date ji 2z ,20 c?3 QQK CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by H.S.B. CT.

of Hartford, CT. Have inspected the components described in this Owner's Report during the period 4/pIIB to ,iX/ŽL/" , and state that to the best of my knowledge and belief, the has permed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or roperty damag or a loss of any kind arising from or connected with this inspection.

____ Commissions /ZZ_-__ _

-Inspector's Signature National Board, State, Province, and Endorsements Date ,20 L9)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT

'As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/09/03 Name 4300 Winfield Rd. Warrenville, II. 60555 Sheet I of I Address
  • 2. Plant Byron Nuclear Power Station Unit 01

- Name 4450 N. Cerman Church Rnad. Rvrnn- II Work Order No. 00419282-09

- Addmrss Repair Organization, P.O. No., Job No. etc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name . ' Authorization No. Not Applicable 4490 N. German Church Road, Byron, II. Expiration Date Not Applicable Address
4. Identification of System RY
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda,1553 Code Case 1974 Edition 'S75 Addenda (Piping)

(b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89 6.- Identification of Components Repaired or Replaced and Replacement Components" National . .eaired. ASME Name of Name or Manuifacurer Board Other Year Replaced. code; Stanped Coteponeint Manufacturer Serial No. No. -

Ideifiaion Built or Rlaceent (Yes or No)

CHECK VALVE WESTINGHOUSE 03000CS82000000 I RY8046 1975

.02W720066 W10349 . REPLACED YES CHECK VALVE. WESTINGHOUSE 03000CS82000000 - - IRY8046 - 1975

.__._-_.__._. 02W720071 . W10367 - REPLACEMENT YES.-

3' PIPE SOUTHWEST RY-7-1 N/A IRY32A-3" 1978 REPLACED YES FABRICATING. SIN: 15888 . -.. _ . *,

3" PIPE Consolidated HT: 29986 N/A IRY32A 2003 REPLACEMENT NO Power Supply - . -_.._____.._:._

7. Description of Work REPLACE CHECK VALVE AND PIPE. ADD AN ADDITIONAL WELD IN THE PIPING
8. Test Conducted: Hydrostatic 2 Pneumatic E Nominal Operating Pressure 0 Other 5 Pressure 165 psi Test Temp. 72 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks WO# 00419282-09 Applicable ManulaCturMr's Data RKports to be attachet Invoked Code Case N-416-1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. repairctetcacament Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Ad 5 Date0 9 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspecte the c mponents described in this O)wner's Report during the period / to o ,and state that to the best of my knowledge and belief, the Tw3ur fias performed examinations a en c rrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner-for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.tComision Inapeor's Sigonuxe

_ __ _ _ _ Commissions // 7 / .. z5-q Nattanal rd. Sate Province, andEnd.r.e.-,s Date / ,20

j FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

-Page 1 of I

1. Owner Exelon Nuclear Date 09/28/03 Name
  • 4300 Winfield Rd. Warrenville, IL 60555 - Sheet -1 ' of 1 Address
2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Chruch Rd. Byron, IL 61010 7Work Order 00422649' -'

Address IRepair Organization P.O., Job No., etc

3. Work Performed By, Byron Mechanical Maintenance Type Code Symbol Not Applicable!.

Stamp 4450 N. German Chruch Rd. Byron, IL 61010 Authorization .No.' Not Applicable Address *Expiration Date Not Applicable

4. Identification of System Pressurizer relief (RY)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addend N/A Code Case Applicable' Edition of Section Xl Utilized for Repairs or.Replacements (c) Section'Xl code Cases used, N/A_-_'_____'_' _-_--_-

.6. Identification of Components Repaired or Replaced and Replacement Components---,

ASME.

Re ~~Code-Name of Name of 'Manufacturer National Other Year pared, Component' Manufacturer Serial No. Board' Identification Built Replacedont(Yes No. . ....-

. . i i-:'1'-'--Replacement e

_ _ _ _ __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~ ~~~No

) .

Safety Valve Crosby. N56964-00-0048 N/A 1RY801 OC 1976 Replaced YES Safety Valve Crosby N56964-00-0030 -N/A--- 1RY801OC 1976 Replacement YES

7. Description of Work REMOVE/REPLACE PRESSURIZER RELIEF VALVE - -I
8. Test Conducted: Hydrostatic a. Pne umati;C Hi pyrNominal Operating 0. '

.Pressure.

Other El Pressure 2339 psi S

P Testp Te p 653

  • . NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x I Iin., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 1 (Back)

9. Remarks Work Order: 00422649 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the repair or replacement rules of the ASME Code, Section Xi.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed _ X,1-, 7) ,fnr owneres Designee. Title Date I___ ,220 E 3 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by H.S.B. CT.

of Hartford, CT. Have inspected the components described in this Owner's Report during the period to ,and state that to the best of my knowledge and belief, the Owner has perfdrm6d examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property darnage or a loss of any kind arising from or connected with this inspection.

__________________________ Com m issions / _1/

Inspector's Signature National Board, State, Province, and Endorsements Date VC ,A t 6 ,20 P3

fL/PtCfAhFW7 FORM NVR-1 REPORT OF REPAIR EM REPLACEMENT 0 OF NUCLEAR PRESSURE RELIEF DEVICES Corrected 5/28/02

. Work performed by: NWS Technologies, LLC Purchase Order# 00041093 Rev. 002 131 Venture Boulevard, Spartanburg, SC 29306

2. Work performed for. Commonwealth Edison Company - ComEd Byron Nuclear Station 3/4. Owner- name, address and identification of nuclear power plant: Byron Nuclear Station 4450 N. German Church Road Byron, IL 61010
5. a: Repaired pressure relief device: Pressurize,r Safety Valve b: Name of manufacturer Crosby Valve & Gag e Co.

c: Identifying nos. HB-86-BP N56964.4DO -0030 N/A  : steam 6 M6 1976 (tpe) . (mrs VsN) (NB#) (service) (size) (yr.built) d: Construction Code: ASME Sec. IlIl 1971 W72 N/A 1 (name/section/divislon) (edition) (addenda) (Code Cases(s)) (Code Class) .

6. ASME Code Section Xi applicable for inservice inspection: 1989 N/A N/A (edition) (addenda) (Code Case(s))
7. ASME Code Section Xl used for repairs, replacements: . 1989 N/A N/A.

(edition) (addenda) (Code Case(s))

8. Construction Code used for repairs, replacements: 1971 W72 N/A (edition) (addenda) (Code Case(s))
9. Design responsibilities: N/A
10. Opening pressure: 2485 psig Set-pressure adjustment made at: NWS Technologies, LLC using steam
11. Description of work (include name and Identifying number of replacement parts): Disassembled, clear ied, inspected, torqued nozzle, lapped, reassembled, set-pressure cert. on steam. Seat tightness using N2.
  • 2. Remarks: NWS Traveler# 02-72 Corrected stamp expiration dates.

0 CERTIFICATE OF COMPLIANCE I, Cesar V. Sierra certify that to the best of my knowledge and belief the statements made in this report are correct and the repair, modification or replacemtn of the pressure relief devices described above conforms to Section XI of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

National Board Certificate of Authorization No. 632 to use the 'VR" stamp expires April 3, 2003.

Nat naloard Certificate of Authorization No. 81 tmp xpires April 9,2003.

I.>4'IPZ. NWS Technologies, LLC // 6 d'2 Manager,QA Date ----- 'Repair Organization Auth~phed represe;aaive Ede CERTIFICATE OF INSPECTION/

1, Charles F. Toegel Jr. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and certificate of competency issued by the jurisdiction of North Carolina and employed by Hartford Steam Boller of CT *of Hartford.-CT have inspected the repair, modification or replacement described in this report on j eyi~nd state that to the best of my knowledge and belief, this repair, modification or replacement has been completed in accordance with Section Xl of the of the ASME Code and the National Board Inspection Code "VR" and "NR" rules.

By signing this certificate, neither the undersigned nor my employer makes any warranty, expressed or implied, concerning this repair, modification or replacement described in this report. Futhermore, neither the undersigned nor my employer shall be liable in any manner for any personal injury, property damage or loss of any kind arising from or connected i thy ins c ion.

NBW8462, A,N,I NC#1073 A a (Date Ins oe'stZSat Commissions (NB (inc endorsements), jurisdiction,& no.)

V ESEST AVAILA13L COPY.

ER-AA-330-009 Revision 0 Page 29 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xli

. . - .Page 1of 4

1. Owner Exelon Nuclear Date 10-2-03 Name ...

4300 Winfield Rd.- Warrenville, IL. 60555 Sheet 1 of 1 Address

'2. Plant - Byron Nuclear Power Station Unit 1 Name 4450 N. German Chruch Rd. Byron. IL 61010 00476919-01 Address . Repair Organization P.O., Job No., etc

.3. Work Performed 2 3V Bvron Mechanical Maintenance

' ' '. - ~ Type Code Symbol Stamp Not Applicable' 4450 N. German Chruch'Rd. Byron, IL 61010 Authorization No. Not Applicable Address Expiration Date Not Applicable

4. Identification of System Pressurizer (RY)'
5. (a) Applicable Construction Code Section III 19-71 EditionSMT2Addenda, -1649Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacemernts 19 89 (c)Section XI code Cases used, NONE
6. Identification of Components Repaired or Replaced and Replacement Components ASME-Name of Name of Manufacturer National Other Year Repaired, Code Component Manufacturer Serial No Board Identification Built Replaced, or Stamped

.No.' '. : .

. . .: "Replacement _

(Yes or

~~~~~~No)

VALVE COPES: 8921-96148- N/A HT#62348 1990 REPLACED YES PLUG VULCAN' 1-4 (90-1) P/N .166192 _____________

VALVE COPES . - 9821-96660- N CAT. ID.# 1 PLUG VULCAN - 1-1 (98-18)

  • 35955 1998 R eplacement Y ES

. . , . . ..... s \- . . ...... .,. , .. .... . ,., . ., ,. . .

of . R. . . d t set

7. < Description Of Work ' Replaced valve trim set I
8. Test Conducted: Hydrostatic a Pneumatic E Nominal Operating Pressure

-Other Ei Pressure 22.3_

5 psi Test Temp. °5OF 9, A337 als NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe use provided (1) size Is 8 1/2 in. xl1In., (2) information in Items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of 3 tm'is,4,f (657 sheets is recorded at the top of this form.

ER-AA-330-009 Revision 0 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi Page 2 of 4

9. Remarks Replaced valve trim set per work order 476919-01.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conform to the repair or replacement rules of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Signed Date 2 z/ , 20 03 Owner rOwners Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by H.S.B. CT.

of Hartford, CT. Have inspected the components described in this Owner's Report during the period 7/,/i _,a nd state that to the best of my knowledge and belief, ato the'Oner has perfo rm'd examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

V Inspector's Signature Commissions /o :-' G oof National Board, State. Province, and Endorsements Date C9:, , 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/06/03 Name 4300 Winfield Rd. Wa rrenville- IL 6055S Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 01
  • . Name 4450 N. German Church Road. Byron, II.' Work Request No. 99179534-01

-. - Address Repair Organization, P.O. No., Job No, etcm

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable' 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable Add=es-
4. Identification of System STATION AIR [SA1
5. (a) ApplicableConstructionCode SectionIII 1974 Edition, W75 Addenda, NONE Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components '19 89-
6. - Identification of Components Repaired or Replaced and Replacement Components National ~~~~~~~~

ed. ~ ~~~Repat ASME anrNam of Maketure board Na Other Yearw epacd4 Cod<, SunVed Con~,ona5 mumbctrer SeW No. No. 'deif-catdon Bulb or Replacement (Yes or No)

P VALVE PLUG MASONEILAN X15980-55 NIA ISA032 1979 REPLACED . NO INT 'L_ _ _ _ _ _ _ _ _ _ _ _ _ _

VALVE PLUG . MASONEILAN 700529-11 N/A ISA032 1999 REPLACEMENT YES.

DRESSER IND. . . .. ..-

7. Description of Work: REPLACE VALVE PLUG - ISA032
8. Test Conducted: Hydrostatic E Pneumatic a Nominal Operating Pressure E N/A Other D Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number' of sheets is recorded at the top of this form.

This faibnhas been clectrnoially generated.

FORM NIS-2 (Back)

Remarks Work Order 99179534-01 a 9. Applicable Manufacturer's Data Reportsto be tached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. Hi, t aplant Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Expiration Date Not Applicable Signed 6B Cacrl Date /z0 ,20 3 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, Ct. have inspected the omponents described in this Owner's Report during the period 7/to _______to_ , and state that to the best of my knowledge and belief, the6Owfier has performed examinations and ta en corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner (or any personal injury or property damage or a loss of any kind arising from or connected with this inspection C msn A

___________ Commissions_______________

, IAnpeat'e Sgaanaue Naot i Boald State ronce ad Ead ena Date 4I, ,t4' , 20 o5

RLE: 3.11.1110 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date ' /15doj .

NA 6 4300 Winfield Rd. Warrenville. E. 60555 Sheet of I

. Address

2. Plant Byron Nuclear Power Station 'Unit 01

-Na.e . -

4450 N. German Church Road, Byron, IL Work OrderNo. 470860-01 Address - - Repair OrganizatiM ,P.O. No, Job No., etc

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable
  • Name Authorization No. Not Applicable 4450 N. German Church Road, Byron, IL Expiration Date Not Applicable

-Address

4. Identification of System SD - BLOWDOWN
5. -(a) Applicable Construction Code Section m 19 74 Edition, W75 AddendaN/A Code Case (b) Applicable Edition of Section M Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Nabo . . RqePae4 ASME Noi of Name of MnuM&Cber . oard oke Year Re Code; siped Cona d MaLifct= Serl No. No. - Idecation tiBuih or Replac (Yes eNo)

VALVEBONNET MASONEILAN K5-16 EPN ISDO54A.

._______ _ :_._._._; _. N/A ._. _---_]_1987 REPLACED. - NO VALVE BONNET MASONEILAN Lt / AN/A CAT ID# 26008.

.__ _ _ , ,- 7. . - _. _ _/ i)'?

-..:3s REPLACEME NTNO

7. Description of Work REPLACE VALVE BONNET
8. Test Conducted: Hydrostatic El Pneumatic D Nominal Operating Pressure I Other 0 Pressure".00JP , psi Test Temp. 0F O4F.1 Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks C6OXK HERW L 72L% 0 - f o CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this &piaIMAo - conforms to the rules of the ASME Code, Section MI. rp Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date /.- ,20OO2 20 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected tl~e components descnbed m this Owner's RIeport during the period to / /Ql ,and state that to the best of my knowledge and belief, theA)Wiier has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this

/ t69'

__ _ _ _ _ _ __ Commissions - 0 Date / ,20 O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/09/03 Name 4300 Winfield Rd. Warrenville, 11. 60555 Sheet I of I Address -
2. Plant Byron Nuclear Power Station Unit 01 Name 4450 N. German Church Road, Byron, II. Work Order No. 00623124-01 -

Address Repai Organization, P.O. No., Job No., etc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable 4450 N. German Church Road, Byron, Il. Expiration Date Not Applicable Address
4. Identification of System SD STEAM GENERATOR BLOWDOWN
5. (a) Applicable Construction Code Section III 19 74 Edition, W/75 Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National e.ed. --

ASME Nanz of Nareof Mmnufr . Board Odtr Year Reptaced. Code,Stanved Con~,ooeol Maaufacurer - Seral No. No. Identikation Built or Repltamnt (Yes or No)

PLUG, VALVE ALTECH 02976.19 N/A ISDO02G 1979 REPLACED NO PLUG, VALVE MASONEILAN- HT: 87367-20 N/A ISDO02G 1987 REPLACEMENT YES

. DRESSER

7. Description of Work REPLACE VALVE PLUG IN I SDO02G
8. Test Conducted: Hydrostatic Xl Pneumatic El Nominal Operating Pressure E N/A Other D Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This formn has been electonically generated.

FORMI NIS-2 (Back)

Remarks Work Order No. 00623124-01

  • 9. Applicable Manutacturers Data Keports to be attached

- CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed r \-i (>>J. Date /20As CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected tJe components descnbed in this Owner's Report during the period ,ty5>/d3 to /Z , and state that to the best of my knowledge and belief, the Owfer has performed examinations an takerf corr ctive measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i on.

_ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Com m issions B/ / v / o ex

(>a~nape I.sP..sigat-c NU-1~e 8-ad. bt.. P-oao. sad MaOn~~ua Date f;< / ,t 20 ( -

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI I. Owner Exelon Nuclear Date 05/15/03 Narne 4300 Winfield Rd. Warrenville, II. 60555 Sheet I of I Address

2. Plant Byron Nuclear Power Station Unit 01 Narne 4450 N. German Church Road. yvrn. 11.L Work Order No. 00432872-01
Address Repair Organization, P.O. No.. Job No., etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Narne - Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. Expiration Date Not Applicable Address
4. Identification of System SX ESSENTIAL SERVICE WATER
5. (a) ApplicableConstructionCode Section II 1974 Edition,W/75 AddendaN/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacement Components 19 89.
6. Identification of Components Repaired or Replaced and Replacement Components

. . i.hNational Repabrd. ASME Na Nameof maoufactumr BoaTrd Ot. Year Replaed. Code; Stamped Co u re Manufacturer Serial No. . No. Identification Bulb' or acement (Yes or No)

CHECK VALVE ANDERSON

.__________ GREENWOOD N26535 N/A - ISX174 1992 REPLACED Yes CHECK VALVE ANDERSON

.. ________ .GREENWOOD N26076 N/A 1SX174 1990 REPLACEMENT Ye

7. Description of Work REPLACE VALVE PER PM PROGRAM - 1SX 174
8. Test Conducted: Hydrostatic ' Pneumatic n Nominal Operating Pressure s Other 9 Pressure' 108 psi Test Temp. 75 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks WO 00432872-01 Applcable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. rep Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date V-2

,20-23 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components described in this Owner's Report during the period _ __ _ to o c-%t)3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for an s injury or property damage or a loss of any kind arising from or connected with this inspection.

Datepeouf's Signata0 Commissions pt A BNc57 y .3w Date <R

-2>i, 0o

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 3/27/03

-- Namne 4300 Winfield Rd. Warrenville, 11. 60555 Sheet I of I

.- -.. , - -. - Address

2. Plant Byron Nuclear Power Station Unit 00

- Name 4450 N. German Church Road, Byron, I.' Work Order No. 474517-01 Address Repair Organization, P.O. No>, Job No., etch

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Namne Authorization No. Not Applicable 4450 N. German Church Road, Byron, ll. . Expiration Date Not Applicable Address
4. Identification of System [SX1 ESSENTIAL SERVICE WATER
5. (a) Applicable Construction Code Section Il .19 74 Edition, S/75 AddendaN/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89

. I

6. Identification of Components Repaired or Replaced and Replacement Components Naionael Rpeivd. ASME Natr of Nae of Manufacturer DOOrdtoer , Year PAcpd. Suoed Coods.

coffyonr- Manumadurf ScriaNo. No. Identifficaon Built or Riapmmn (Yes or No)

UPPER SEISMIC N/A N/A . H-FSK-14-1 1984 REPLACED NO RESTRAINT HUNTER . ETN:OSX02PA

%ASTUDS HUNTER N/A N/A ETN: OSX02PA REPLACED . NO

.___. __. __.___. H -FSK-14-1 1984 . .1.  :

W" STUDS - Nova Machine Heat # 14534 N/A ETN: OSX02PA . NO

. . Cat ID# 37094 2002 REPLACEMENT I/;" Hex Nuts HUNTER N/A N/A ETN: OSX02PA 1984 REPLACED NO

_ H-FSK-14-1

-" Hex Nuts Nova Machine Heat # B87035 N/A . ETN: OSX02PA 2002 REPLACEMENT. NO

._____ .__ _ . . .-; . , . . Cat ID: 37031

7. Description of Work MODIFY SEISMIC RESTRAINT PER DCP 9900414, REPLACE 3/4" ORIGINAL BOLTING
8. Test Conducted: Hydrostatic 1 Pneumatic E Nominal Operating Pressure E Vf 1-- 3 Other 3 Pressure ' psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 1I in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This forn has been electronically generated.

FORM NIS-2 (Back)

9. Remarks Work performed per Work Order 474517-01.

Applicable Manufacturer s DataReports to beattached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. eparormplatM Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed (C)aA C . Aj l Date 4 - ,20 03 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period / to 6 - , and state that to the best of my knowledge and belief, the Owner has performed examinations and ta n corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins ection.

__ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Commissions Z npw0t a Sigpwa Na- oard. ProvnMc.SadEuidoeents boal S1a1e Date 0 3

.I I.

I ..

. I I 1 I. I FORM NIS-2 OWVNER?S REPORT FOR REPAIRS O~R REPLACEMENTI' I.

1, I As Required by thiPr'ovisions of th ASMEC CodSection XI L'.I.: -'~fi Exclon Nuclear . ... I Daje 4/3/03 4300 Winfield Rd, Warrenville, IL 60555 Sheet i I of I
  • * ~~Address .. -- I *. I
  • 2.. Plant Byron Nuclear Power Station Unit n/a - sp'are valve

.Narne. .

  • 4450 N. German Chur'ch Roaid. Byron, II. .Pur~chisi Oider No. 00051692
  • . . . 3 ~~~~~~~~Address. '1.'"Repir OrganizatidN,..0.No.,Job'No, etc.-
3. 'Work Perfonxied by Anderson Greenwood Crosby Type Code Symbol Stamp Not Applichlble
  • . Name. *. . ~~~~~~~~~~-Authorizationi.No. Not Aviplicible .

.1

  • ~~~1655 Jarvis Ave, Wrentham MA'60007 - *,piratibb Date Not Applicable .

Address . . *' i~

4 "Identification of Systeijr E.ssential Service Water (SX) '

5. (a) Applicable Construction Code Section III 1974_" Edit~on, W/n5 'Addenda,'. Code Case n/a ~

.I (b); Applikable Edition o ecioXi Utilized for Repairs IRiea6 ct Cmoet 19$ 9

- Mep dnt.cti'o ensRcpaired~or Replaced ind Replacemen 'Components Nvyi Nune bf of Mamfoc"M ~~board NsioamI .. te- I Yaar . ~~~~~~~~~ ~~Rspialr.

ftepI~ced~ . ASME Obde. Stanved Coony,, Ma~mficturer Si~rWNo. .No. Idrvifkatiom %fi~f or lteplacemni **fYescir No) 30'.Check Valve .Anderson . .N-95150-01.0Q03 . -

  • stn-AI29 -1978 Repaired.- - yes

______________Gteenv,~ood . (aflef repair) .(prior io repair)

7. Description of Work: Valve seat refurbished with stainless steel overlay per purchase order 0005 1692
8. Test Conducted: Hydrostatic Z Pneumatic El Nominal Operating Pressure 03 Other [D Pressure 425 psi *TestTemp. n/a . O Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size' is 8-1/2 in. x I I in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of -.

sheets is recorded at the top of this form. .

This ronn has been clectnonkally genratsed.

FORM NIS-2 (Back) 1,

. I

Remarks This check valve is a spare. This form provides traceability from the current s/n N-95150-01-0003 I9. (after refurbishment) to the original ASME form NPV-I s/n A 129. This N]S-2 addresses refurbishment of The valve and does not cover future installation into the plant.

Applicable Manufactrer's DataReportsto be attached CERTIFICATE.OFCOMPLIANCE . , . '

We certify that the statements made in the report are correct and this repair conforms to the rules of the ASME Code,.

Section Xi. .epl, .  :

Type Code Symbol Stamp Not Applicable  : . . ,

Certificate of Authorization No. Not Applicable I I Expiration Date Not ApplicablW, Signed Il) 1 v- A.. Date 9- i ,20_ 03

. .. . W , . . .~~~Cigm CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by-the National Board of Boiler and Pressure Vessel Inspectors and the State or Proaince of Illinois and employed by iSBCT of Hartford, Ct. . . havelins e components described in this Owner's Report during the period . . i to ' 5/j.S , and state that to the best of my.

knowledge and belief, the.O'wn6r has performed examinations and takeA corrective measures described in the Owner's Report in accordance with.the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.. Furthermore, neither the Inspector nor his employer shall be lialple in any manner for any personal injury or property damage or a loss of any kind arising from or. connected with this ins ecton. . -

-______________________-___ Commissions _________________________

Datg N.-e aad, Sat Pre.., a E20dom Date ,20 6'

-l-

§-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 09/03/03

. Nam 4300 Winfield Rd. Warrenville, IL 60555 - Sheet I of I , '

- - Addre-s

'2. Plant Byron Nuclear Power Station Unit 01

. Nam .

4450 N. German Church Road. Byron, 11. Work Recquest No. 00518423-03 HAessd - - Repair Organizaion. P.O. No.. Job No. etc.

3. Work Performed by Byron Mechanical Maintenance' Type Code Symbol Stamp Not Applicable Narne - Authorization No. Not Applicable 4450 N. German Church Road, Byron, D. Expiration Date 'Not Applicable Addss 4.' Identification of System ESSENTIAL SERVICE WATER (SX) ..

'5. ' (a) Applicable Construction Code Section III 1974 Edition, W75 Addenda, None Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89

6. . 'dentification of Cornponents Repaired or Replaced and Replacenent Components

. ..I ,. .

.. . * ,. Na d. _Re ASME I .

  • mNof * .Name oor Bae  ; .* boad Odhe Yew , ePW4ad. Code.Swred W..

.1  :

Coavooa VALVE DISC MaWNmhmer DRUMMAND MCCALL &CO .

sw.NNo.

N/A No.

N/A

  • IdeN *oen ISX124B .

SWa-i" 1978 or Reisonm*

REPLACED (Ye or No)

NO:

VALVE DISC VELAN INC. - S/N: 4876 N/A ISX124B 2002 REPLACEMENT YES

7. Description of Work: REPLACE VALVE DISC AND TACK WELD DISC TO DISC UNION - ISX124B
8. Test Conducted: Hydrostatic 0 Pneumatic Q Nominal Operating Pressure 0

/pAf Other a Pressure_ psi Test Temp. -OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x I I in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generaued.

FORM NIS-2 (Back)

9. Remarks Work Request No. 0051 8423-03, Applicable Manufacurer's Data Reportsto be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. i, W Rn. '

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Expiration Date Not Applicable Signed Date J ii ,2007 CERTIFICATE OF INSERVICE INSPECTION I 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of lllinois , and employed by HSB CT, of Hartford, Ct. have inspected She components described in this Owner's Report during the period Z6V/O to He/,/ ,and state that to the best of my knowledge and belief, the Owner6as performed examinations and taketfcofrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- __________________________ Commissions ,I -/Z sf tn~,w~ 1 S Saigh Na,.oeaNB-and. S--, G - E-p

-d, ad a Date ,20 s

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. ' Owner Exelon Nuclear Nant

_ Date . ffl-,2-F-03 -

4300 Winfield Rd.'Warrenville. 11. 60555 Sheet I of I

  • Address
2. Plant Byron Nuclear Power Station Unit 00

-. - . .. N... eNan 4450 N. German Church Road, Byron, 11. Work Order No. 00575126-01

- - - -- - Address - - Repair Organization. P.O. No.. Job No., etc.

3. Work Performed by Byron Mechanical Maintenance -Type Code Symbol Stamp Not Applicable Nae . - -Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable Address 4; Identification of System [SXj ESSENTIAL SERVICE WATER
5. (a) Applicable Construction Code Section III 19 74 Edition, W75 Addenda,1567 1682 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components.

National . e .. ASME.

. of Nae of *anwfctwr .: Board Othr YearRe e CokStaned Copownt Mamaatunrw SialNo. N' ' ' '_"i__on

_.No. Built rRtsen ' orNo)

DISC ANCHORIDARLI S/N I OSX063A

.__________ NG VALVE CO. HT# D8755 . NA - 1978 REPLACED NO DISC ANCHORIDARLI S/N 3 . . CAT ID 1392097-1 NG VALVE CO. HT #T9930 N/A 0SX063A 1992 REPLACEMENT YES DISC ANCHORIDARLI S/N 3 CAT ID 1392097-1 NG VALVE CO. HT #T9930 N/A OSX063A 1992. REPAIRED YES

7. Description of Work REPLACE VALVE DISC IN OSX063A. MACHINE REPLACEMENT DISC FOR FIT.
8. Test Conducted: Hydrostatic E Pneumatic l Nominal Operating Pressure E AJ/24 Other El Pressure ' _ _psi Test Temp. `F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks INVOKED CODE CASE N-528-1 FOR TRANSFER OF MATERIAL BETWEEN NUCLEAR PLANT SITES AppIcable Manuhacturers DataReports to be attached WO 00575126-01 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement & Repair conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Omnaiyj &A rkl Date //_0 ,20 03 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid comniission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspectedJhe components descntbed in this Uwner's Report during the period __ _ ___ __ to ,//' , and state that to the best of my knowledge and belief, the Ov~nef'has performed examinations and takdn corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ Commi s i ons __

llr/nal _ _ _ _

srg_ltae _ AandCommissions _

InD e O aias20r's ta Date // / / , 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 1/8/1999

-Nam

4300 Winfield Rd. Warrenville. IL 60555 Sheet I of I

- - Addrss

2. Plant Byron Nuclear Power Station Unit 01

- - :. .... Nume 4450 N. German Church Road, Byron. U. ' Work Request No. 97124110-01 Addre ' . Repair Orgnitio, P.O. No.. Job No., et.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable NumZ

-- . ........... No. Not Applicable

.=.Authorization 4450 N. German Church Road, Byron, n. Expiration Date Not Applicable

4. Identification of System 6xec h;1i5r16qrc io /er (xx)
5. (a) Applicable Construction Code Section III 1974 Edition, s/75 Addenda, hlo Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89 (c) Applicable Section XI Code Case(s) NONE_ _
6. Identification of Components Repaired or Replaced and Replacement Components' Na.o.al Rq..ed. ASME Nam of NNWOf b~OthearCd. epke4 Sod CToner MM&CWer Sar No. No. Idewifiatoi - Built or Relobscmmt (Yes or No)

Orifice Flange Coffer Corp. HT Code: VBP7 N/A SI 703D23 1997 Replacement No

____ _-_____ ___ ______ _______ ___ ____ ____ ____ OFE -28 6 _

Pipe- 6" Sch. 40 US Steel Corp. HT # X04284 N/A SI# 768A33 1995 Replacement No SA-Io6 Gr B  :  : OSX79BB M." Hex Nut SA- Nova HT Code EKP N/A Sl# 796DOI 1997 Replacement No 194 Gr2H HT# 8098740 OFE-286

%1"Threaded Rod Nova , HT Code: HCY NIA. SI# 796D75 1997 Replacement No SA-193GrB7 HT# 55173 OFE-286 .

Orifice Plate Energy Steel & HT# AB83 N/A SI# 706F21 1998 Replacement No Supply OFE-286.

7. Description of Work: Install new orifice Flange per DCP 9700732 (OFE-286)
8. Test Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure .

Other Q Pressure 15-20 psig Test Temp. 70-80 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This fon Was been ekctronically genenaietL

FORM NIS-2 (Back)

  • 9. Remarks WR 971241 10-01 Applicable Manufcrn's DataReporu to be uttacbd Replaced pipe OSX79BB-6", was Class D. Replacement Pipe and orifice flange is ASME Section III, Class 3.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. p,.., bt Type Code Symbol Stamp Not Applicable Certificate of Aythorgtion No.,ot Applicable Expiration Date Not Applicable Signed S KiZ.4 R o4A Date RI,) ,20 93 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, Ct. r - have inspected thee components described in this Owner's Report during the period 9 /, to A , and state that to the best of my knowledge and belief, the OvWer has performed examinations and takerorrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ Commissions - /

-ac Dlbote

~ ~ ~ j r',S3 Date DS.b ,00

FILE: 3.11.1110 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT

- - As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 09/24/02 Name -

4300 Winfield Road, Warrenville, l. . -- Sheet I of 1

. Addres

2. Plant Byron Nuclear Power Station -Unit 01 Nme 4450 N. German Church Road. Bron. TIL Work Reauest No. 98081535-01/08 Address Repir Oralnration. P.O. No. Job No., etc.
3. Work Performed by N P S & W VENTURE Type Code Symbol Stamp Not Applicable Nane Authorization No. Not Applicable 55M S. Joliet Rd, Bolingbrook, IL. 60440 Expiration Date Not Applicable Addess
4. Identification of System Essential Service Water (SX)
5. (a) Applicable Construction Code Section III 19 74 Edition, Sf75 Addenda, none Code Case

-~ (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89 No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components Coowooe~~v maanuletur Nan~~~~~eot Nan~~~~~~~~~eot S'edal N'o.

NO

-I

~~~~~~~~~Repafrad.

Idefftifkstton BusN or Replaceen=

f ASME (Yesor No) a BOLT, STUD

  • l-1/2"X 19-3/4" BOLT, STUD HUNTER CORP HT CODE# HP-34 N/A ISXo01B' 1978 REPLACED N 1-1/2" X 19-3/4" I NOVA MACHINE HT CODE#E880 I N/A ISX001 B 2002 REPLACEMENT NO BOLT, STUD 1-1/2" X 7-3/4" HUNTER CORP HT CODE# HP-37 N/A ISXOOIB 1978 REPLACED NO BOLT, STUD 1-1/2 x 7-3/4" NOVA MACHINE HT CODE# E880 N/A ISX001B 2002 REPLACEMENT NO BOLT, STUD 1-1/2"X 7-1/4"' HUNTER CORP HT CODE# HP-36 N/A ISXO0IB 1978 REPLACED NO' BOLT, STUD I-In2"X7-114" NOVA MACHINE HT CODE# E880 N/A 1SXOOIB 2002 REPLACEMENT NO NUTS, H.H.

1-1/2" HUNTER CORP HT CODE# HP-38 N/A 1SX00IB 1978 REPLACED NO NUTS, H.H.

1-1/2" '

  • NOVA MACHIN HTECODE# D303 N/A1 SX00IB 2002 'REPLACEMENT NO
7. Description of Work Replaced all 32 valve studs and 64 nuts.
8. Test Conducted: Hydrostatic [D Pneumatic 0 Nominal Operating Pressure E H'1A I.

Other M Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This (rcihas been eLectronically genemte&

FORM NIS-2 (Back)

9. Remarks This NIS-2 documents valve studs and nuts replaced under work orders 98081535-01 and 98081535-08. The studs and nuts were replaced one at a time, the pressure boundary was not broken.

Anppiabe Manufactumr's Data Rqwol tobe anached .-

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable Expiration Date Not Applicable Signed Date / ,20 0.;>

CERTIFICATE OF INSERVICE INSPECTION Go I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by H.S.B.I&I-e. Cr of Hartford, CT have inspected the components descnbed in this Owner's Report during the period _ 5S /z to , and state that to the best of my knowledge and belief, the OCWnei has performed examinations and takef corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspe zign,

_ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Com m issions / 1f'-/Z.5 'Y

.ate a 20 Se Na am am Date  ; ,20 d'7g

  • 6 ~~~~~~~~~~~~~~~~~~~~~~~

S .

FORM NIS-2 OWNN'ER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 04/17/03
  • . ' ' - Narnme 4300 Winfield Rd. Warren ville. IL 60555 Sheet 1 of I

- -- - Address ,

2. Plant Byron Nuclear Power Station Unit 01 -

I Name ' .

4450 N. German Church Road, Bvron, 1;, Work Request Nb. 99000336-01 Address ' - Repair Organization. P.O. No, Job No. etc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Nane . Authorization No. Not Applicable 4450 N. German Church Road, Byron, n. Expiration Date lNot Applicable Address
4. Identification of System Essential Service Water (SX)
5. (a) Applicable Construction Code Section III 1974 Edition, W75 Addenda, None Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components board ~~~~~~~~~~ ~ CoA:SM~E

~~~~Repaired.

d

.a e o Na e o  ?.i amf cwr Nl I ' - . fra. R SME bA

. Nnc of N&=cof . morufi turer bo Ihe d

or Y ~ .

dew Rep=

.Codc: Sutaed Conya. nu ) sfaourer SeialNo. No. ' IdentWtion Buit orRem (YetorNo)

VALVE DISC Anchor/Darling 'S/N: R34811 N/A OSX161B 1978 Replaced . No Valve Co. .HT:

M- Al607V Valve SIN: E-6220-4-10 I I I VALVE DISC Flowserve Corp SIN: 3 N/A , OSX161B 2000 Replacement. Yes -

.____________ HT: B6516; -

VALVE DISC Flowserve Corp S/N: 3 N/A . O0SX161B 2000 . Repaired Yes

. ___________.H _ T: B6516 . , , . '

BONNETSTUDS Anchor/Darling HT:8888960 NIA OSX161B 1978 Replaced No' Valve Co. . _ Valve SIN: E-6220-4-10 BONNET STUDS Nova Machine HT: 7404456 N/A OSX161B 2002 Replacement No Products Code: F469 .

BONNET HEX AnchorlDarling HT: X44392 N/A OSX161B 1978 Replaced No NUTS . Valve Co. . Valve SIN: E-6220-4-1 0 BONNET HEX Nova Machine . HT: B87035 N/A OSX161B . 2001, Replacement No NUTS ' Products Code- B711 --

7. Description of Work: Replace Valve Disc and Bonnet Bolting. Machine Replacement Disc to Fit Valve.
8. Test Conducted: Hydrostatic E Pneumatic E Nominal Operating Pressure 0 Other a Pressure 15 psi Test Temp. 70 `F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This fonn has been electronically generated.

FORM NIS-2 (Back)

Remarks WO 99000~336-01 a 9. Apphcablc0anufacturer s DataReportsto beattached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement &.Repair conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable . Expiration Date Not Applicable Signed Go 4 3<R,?_ CvbrA, - Date oI 5 ,20O3i CERTIFICATE OFJINSERVICE INSPECTION

], the undersigned, holding a valid commission issued by ihe National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by HSB CT of Hartford, Ct. , have inspectedbhecomponents described in this Owner's Report during the period to .//6 / , and state that to the best of my knowledge and belief, the Owner hag performed examinations and takes c rrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner fQr any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- 1 d~4~4' Commissions /1/ -

D a e r Sigure 20 3no Bord StainNotinca.

National andEndoran a Date t/t ,2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 10/04/03 Name 4300 Winfield Rd. Warrenville, D. 60555 Sheet I of I Address
2. Plant Byron Nuclear Power Station Unit 01

- Name 4450 N. Cerman Church Road. Bvron. II. Work Request No. 99118092-04 Addresa Repair Organization, P.O. No., Job No, etc.

3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable

Name Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable Address

4. Identification of System SX ESSENTIAL SERVICE WATER'
5. * (a) Applicable Construction Code Section III 19 74 Edition, W74 AddendaNO Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components

.-_. . *......... Natio lI - . Rqareda ASME Na of Naorf Maoforr . dar Other Year

  • RepacI Code; Stanmped

.co-on M.mmct_ SerialNo. No. .&S l MeMifioln Built orfItelacernevt (Yesor No)

PUMP CASING BINGHAM- 16210001 ISXO1PA TOP WILLAMETTE ATLAS NB 529 1634-76-1 TOP CASE 1978 REPAIRED YES PUMP CASING BINGHAM. . 16210001 . 243-77-1 BOTTOM BOTTOM WILLAMETTE ATLAS NB 529 1SXoIPA 1978 REPAIRED YES

7. Description of Work REPAIR ERODED AREAS OF PUMP CASINGS.
8. Test Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Other E Pressure 114 psi Test Temp. 70 *F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This fxt has been electronially generated.

FORM NIS-2 (Back)

9. Remarks WO# 99118092-04 Applicable Manufacturer s DataRepons to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. irolemm Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed A\  : M Date ,20O's CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components described in this Owner's Report during the period o to AVla / , and state that to the best of my knowledge and belief, the Owvnerhas performed examinations an ten corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with.

this inspection.

_ _ _ _ _ _ _ _ _ __, _ _ _ _ _ _ _ _ _ _ _ _ _ C om missions 1/

%/ -/ m'*

Date 7 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 05/30/02 Narme

.a.n . r_ fla "A - ..!I* T2 e nrpr 30UU0winneiu Ma. Warrenville, 11.out05 Sheet I of I

-.-Address

2. Plant Byron Nuclear Power Station Unit 01 Nane 4450 N. German Church Road, Byron, II. Work Order No. 99152947-01
  • - - ~~~~~Addrms Repair Organization. P.O. No., Job No. etc.
3. Work Performed by. Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable 4450 N.Gm C r Nadm, , Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. Expiration Date Not Applicable Addrs -
4. Identification of System Essential Service Water (SX)
5. (a) Applicable Construction Code Section III 19 74 Edition, W/75 Addenda, None Code Case (b) Applicable Edition of Section X1 Utilized for Repairs or Replacement Components 1989
6. Identification of Components Repaired or Replaced and Replacement Components I T - ~~~~~~~~~~~~National Repaired. T ASME Nameof N& of MAnUfactwrer 8

-oard other c Yar Relce. Co&-, Statrped Cono VALV CHEnCK m In Ma. cwrSerial ANERSnufcue No. No. j deWiftcato uflbI or epqlacernm I. (Yes rNo)

CHECK VALVE ANDERSONO A129 ISX002A 1978 GREENWOOD N/A REPLACED YES a-,

W -- 1 - -- t 4- +

CHECK VALVE ANDERSON N95150-01-M02 1978 GREENWOOD N/A CAT ID 1034815 REPLACEMENT YES STUDS ANDERSON N05-2103-039 1978

. GREENWOOD N/A ___._._. _ REPLACED NO STUDS ANDERSON HT # 778528 1997

.________ -GREENWOOD . N/A CAT ID 036074 . REPLACEMENT NO NUTS ANDERSON NOS-2105-008 1978 GREENWOOD N/A . REPLACED NO NUTS NOVA HT# 8099725 2002 .

MACHINE . NIA CAT ID 035845 REPLACEMENT NO

7. Description of Work REPLACE EXISTING VALVE WITH REBUILT VALVE
8. Test Conducted: Hydrostatic 0 Pneumatic E] Nominal Operating Pressure 3 Other D Pressure 98 psi Test Temp. 72 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks Work Order 99152947-01. Prior to being rebuilt, replacement valve s/n N95150-01-002 was originally s/n A-231.

A-DI-hb M-nufli--w'. Dat R- tobe*bc

-on CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed (iA ( T Date ./9 ,20 au.-

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspecte the components described in this Owner's Report during the period .S/g. to , and state that to the best of my knowledge and belief, the Owfer has performed examinations and taen corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________mCommissions _ __ _ __ __ _

Date £;4 9...g . , 20 L

oSl FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 09/27/03 Narn 4300 Winfield Rd. Warrenville, IL 60555 Sheet I of I Address -
2. Plant Byron Nuclear Power Station Unit 01 Narn 4450 N. German Church Road. Byron. n. Work Request No. 99167407 Address... Repair Organizstion. P.O. No>, Job No.. etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Narn , Authorization No. Not Applicable 4450 N. German Church Road, Byron, 1I. Expiration Date Not Applicable

- ~~~~~~~Address

4. Identification of System Essential Service Water (SX)
5. (a) Applicable Construction Code Section III 1974 Edition, W75 Addenda, None Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Natiunal -. .. ASME Nmieow rNuxof ).tu~u~rfac bwoard her Yearw oe Code Swped coboep Mamincer Serial No. No. - IdentifiaIo Built orT bennmr (Ye. or No)

VALVE DISC VELAN S/N: B-72 N/A ISX168 . 1979 REPLACED NO VALVE DISC VELAN S/N: 4909 N/A I.SX168 2003 REPLACEMENT YES

,BONNET STUDS VELAN N/A N/A 1SXI68 1979 REPLACED NO (10) . ._._._VLV SIN: 79G095 . . . .

0BONNET STUDS NOVA MACHINE CODE: F391 NIA ISX168 2002 REPLACEMENT NO .

I (10) PRODUCTS HT: 142710 . . .

,BONNET NUTS VELAN NA N/A 1SX168 1979 REPLACED NO (20) . VLV SIN: 79G095 -

BONNET NUTS NOVA MACHiNE CODE:: j273 N/A ISX168 2003 REPLACEMENT NO Il (20) PRODUCTS HT: B87035 ._._-___

7. Description of Work: REPLACE VALVE DISC AND BONNET STUDS/NUTS
8. Test Conducted: Hydrostatic , Pneumatic D Nominal Operating Pressure E VT Z Other 0 Pressure psi Test Temp. OF J7 0 /tC 4.

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This fom has been lecironically venerated.

FORM NIS-2 (Back) p 9.

  • Remarks Work Request No. 99167407 Applhabl Mmiutaclurer's Data Repons to be attached CERTIFICATE OF COMRLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair orqrep.e Type Code Symbol Stamp Not Applicable Certificate of Authorization No. Not Applicable , Expiration Date Not Applicable Signed Date 10/i, ,200J3 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois I. and employed by HSB CT of Hartford, Ct. . have inspectej the components described in this Owner's Report
  • during the period :2/X y91s-75 to _/_f/ ^ _ , and state that to the best of my knowledge and belie( the Ownfr has'performed examinations and talen c~rrective measures described in the Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __I_ C o mmissio n s __ _ _ _ _ _ _ _ _ _

D Aa 20year.r'rx Narinial rd.9n Pro.,ndErns Date 46 > ,20 0'3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT

- As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 02/20/03 Namne 4300 Winfield Rd.' Warrenville, 11. 60555 - Sheet I -- of I Address
2. Plant Byron Nuclear Power Station unit 01' Name 4450 N. German'Church Road, Byron, 11. ' Work Request No. 99215439-01 Address Repair Organization, P.O. No., Job No, ec.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name -.: --* - '-: Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. Expiration Date Not Applicable Address
4. -Identification of System [SXI ESSENTIAL SERVICE WATER [I-SX-2-N51
5. (a) Applicable Construction Code Section III 19 74 Edition,S/75 AddendaN/A Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacement Components i9 .89 -
6. Identification of Components Repaired or Replaced and Replacement Components NatioWs lq.Rebd. ASM4E N )am Of.r - oi No. . b otfrb Yaer RePoleed. Code; Sanved c_____sr___ M_ acr _ er_l No. No. Ideifon Bui or Replceme (Yes or No)

VALVE JAMESBURY S/N: N/A . EQUIP# ISX052A 1978 REPLACED YES l__._.__._. ND48858-07-A . . .__. .___

VALVE JAMESBURY S/N:. N/A - - EQUIP# ISX052A 1978 REPLACEMENT. YES 7/8-9 STUDS TEXAS BOLT FZ 8SX92A- N/A . EQUIP # 1977 REPLACED NO HEX NUTS TEXAS BOLT FZ9 N/A EQUIP# ISX052A 1977 REPLACED NO 718-9" STUDS NOVA'MACHINE HT: 63819-322 N/A - EQUIP# ISX052A 1997 REPLACEMENT NO

.___,PRODUCTS

_ CODE: DYR . ._._._'_

HEX NUTS NOVA MACHINE HT: 8077124 N/A EQUIP# ISX052A 1999 REPLACEMENT NO

. PRODUCTS CODE: NLR ,__._.-

.'.'...,..~~~~-

7. Description of Work REPLACE VALVE AND FLANGE BOLTING. VALVE I SXOS2A
8. Test Conducted: Hydrostatic El Pneumatic E Nominal Operating Pressure 0 Other 0 Pressure 95 psi Test Temp. 70 OF Note: Supplemental sheets in form of lists, sketches,- or drawings maybe used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number 0 of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks The shaft/wafer assembly in the replacement valve was previously replaced in WO 992l5439-04. The new le 9. Applicable Manutacturcr aDaal Reportsto be attached wafer S/N in the replacement valve is PLP-1.

WO 99215439-01 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. mp,,-,lan,.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed tvE Date gj 5 ,20 03

-CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid comriiission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by HSB-CT of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period / 3 to ,and state that to the best of my knowledge and belief, th OwnEr has performed examinations and takn Qorrective measures described in the Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspcin this i~~ecfl~~~~, Commissions/1-/ S 6 4 Date pomomi nauoon Swe Nll oaHoard, cadoraor Paortoa.

aod Date_ 8 , 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions ofthe ASME Code Section Xi

1. Owner Exelon Nuclear Date 01/14/03

-. - Name - -

4300 Winfield Rd. Warrenville,Il. 60555 Sheet I ' of I

- Address

2. Plant Byron Nuclear Power Station Unit 01 Narm 4450 N. German Church Road, Byron, 11.' Work Order No. 99261578-01 Address Repair Organization. P.O. No., Job No., etc.
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name , Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. Expiration Date Not Applicable Address
4. Identification of System [SXi ESSENTIAL SERVICE WATER
5. (a) Applicable Construction Code Section III 19 74 Edition, S/75 Addenda, N/A Code Case I (b) Applicable Edition of Section X1 Udlized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Noae of Na=e of Manufacturer r .- , National board OthI Year Repuird.

Replaced, ASME Code; Stomped comw I__ _ MaIfaurer Seriul No I No. _ detifcaion I BuiNt or Replacement (Yes or No)

BUTTERFLY JAMESBURY ND-48858-14B I NIA EPN:ISX150B 1978 REPLACED YES VALVE

_~  :: =_ _.  : _. _ .. 4 _

NW IBUTTERFLY ENERTECH 11114 N/A CAT.]D.# 1034054 I12002 REPLACMENT YES DWG: MD20636

7. Description of Work REPLACE 8" BUTTERFLY VALVE
8. Test Conducted: Hydrostatic 5 Pneumatic 0 Nominal Operating Pressure s Other 5 Pressure /02 psi Test Temp. .3 'F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronicatly generated.

FORM NIS-2 (Back)

Remarks butterfly valve replaced per Work Order 99261578-01.

Applicable Manufacture's VatsReports to be attached I

I I

I I

I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. wiararapoamaa Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed (,A.4 Date 7 ,20 0 I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspecte) the omponents descnbed in this Owner's Report during the period _ to _ V 17 , and state that to the best of my I knowledge and belief, the Own&r has performed examinations and taken e6rrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N 4r--/ 9psN Commissions______ __ ____ I Jnvnctr's t Date J1;4P20 ,3 I

01'C 5.11.11kv

. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Namie 6 Date 05/29/02 , I 4300 Winfield Rd. Warrenville. In. 60555 Sheet I of I

. Add

2. Plant Byron Nuclear Power Station Unit 01 I 4450 N. German Church Road, Byron, P. Work Order No. 99261579-01 A..es

, . ~~Addiess - Repair Organizaton, P.O. No., Job No., etc.

3. Work Performed by Byron Mecha'nical Mainte'nance Type Code Symbol Stamp Not Applicable Nam d, o . Authorization No. Not Applicable 4450 N. German Church Road, Byron, D. Expiration Date Not Applicable Addness
4. Identification of System Essential Service Water (SX) -
5. (a) 'Applicable Construction Code Section HII 19 74 Edition, S/75 AddendaN/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 1989
6. Identification of Components Repaired or Replaced and Replacement Components F 1 9 A~~~~

M0/h~~~~~~N Naineof ofm 1 ofnre  ! of Manufact. ~~~~~~~~N

. ationa board l oth Ya t- R epuired.

Replaced, der A SM C 0k E Staked CWr"oeo nactuer SerialNo. No. Identiication Bulk or Reploeontet . (Yes or No) 13UTCbFLY JAMESBURY ND-48858-14A EPN: ISXI50A 1978 REPLACED YES VALVE ._. _. _. _ . N/A ._. _. _.

BUTTERFLY ENERTECH SIN: 11115 CAT ID# 1034054 - 2002 REPLACEMENT YES VALVE - :_._-_. _. N/A - DWG: MD20636 - ._._.

7. Description of Work REPLACE 8" BUTTERFLY VALVE
8. Test Conducted: Hydrostatic I Pneumatic 0 Nominal Operating Pressure 3 Other Q Pressure. 98 psi Test Temp. 72 OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I)'size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been leectronically generated.

FORM NIS-2 (Back)

9. Remarks Work Order 99261579-01.

I I

I I

I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. _

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed A)12h{4L , Date 1/0 j ,20 0; I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the mponents descnbed in this Owner's Report during the period 4/Z7/n to Jo/^1 , and state that to the best of my I knowledge and belief, the Owier has performed examinations an tad corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectioC

____________________ ________________ _ Comm issions NU/ o~g 5 .

Date - /4/ ,20 j

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. - Owner Exelon Nuclear - Date 09/18/03 . .

Nam 4300 Winfield Rd. Warrenville. B. 60555 Sheet I of I

2. Plant Byron Nuclear Power Station Unit I Naim 4450 N. German Church Road, Byron, n. Work Request No. 00420900-01 MAddss Repair Organkation, P.O. No., Job No., e.
3. Work Performed by Byron Mechanical Maintenance' Type Code Symbol Stamp Not Applicable Narn . - . Authorization No. Not Applicable 4450 N. German Church Road, Byron, Il. Expiration Date Not Applicable
4. Identification of System VQ
5. (a) Applicable Construction Code Section III 19 71 'Edition, W73 Addenda, 1682  : Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 19 89 6.- Identification of Components Repaired or Replaced and Replacement Components -

Natioal "Reped. ASME Name of NamNof .. maetwer board Other Year Replaced. Cod- Sturped COUPnee Mawnfarnaw Serial No. No. Idardficetion Built of Replacerrem (Yea or No)

EQUALIZATION JAMESBURY NC17016-02T N/A EPN IVQ5001 B 1975 REPLACED YES VALVE CORP . :_....__. ._

EQUALIZATION JAMESBURY NC17016-02P N/A EPN IVQ5001B 1975 REPLACEMENT YES VALVE CORP THREADED ROD CHICAGO N/A .N/A EPN 1VQ501B 1977 REPLACED NO

. BRIDGE & IRON THREADED ROD NOVA MACHINE HT: 67741 N/A EPN IVQ5001B 1999 REPLACEMENT NO

,___,___.__ PRODUCTS 'CODE: PAH N.

HEAVY HEX CHICAGO N/A N/A EPN IVQ5001B 1977 REPLACED NO NUTS BRIDGE &IRON HEAVY HEX NOVA MACHINE HT: 83038. N/A EPN I VQ5001 B 1997 REPLACEMENT NO NUTS (15) PRODUCTS CODE: FBG ._.._-.-.

7. ' Description of Work REPLACE VALVE AND FLANGE BOLTING - I VQ5001 B
8. Test Conducted: Hydrostatic El Pneumatic l Nominal Operating Pressure 0 Appendix J Leak Rate Test Other D Pressure 45.6 psi ;TestTemp. Ambient 'F Note: Supplemental sheets in form of lists, sketches, or drawings may.be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items .1through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This forn his been ekecronically generated.

FORM NIS-2 (Back)

9. Remarks WO# 00420900-01 Appitcable Manhacturers Data Reports to beattched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Date ((/p , 20 93l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. have inspectedthe components descnrbed in this Owner's Report during the period q/,17/z to IIIZ,516, and state that to the best of my knowledge and belief, the Owfier has performed examinations and tak ncdrrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Comm issions Xh s9 DateMNUwa. mmut ne m Eadaowa,2ts Date ;71W4 25 ,20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. - Owner Exelon Nuclear Date 09/19/03  : .  :
  • Natn

- . . - 4300 Winfield Rd. Warrenville, E. 60555 Sheet i1 of I

- Address

2. Plant Byron Nuclear Power Station Unit I Nn e
  • 4450 N. German Church Road, Byron, Il. Work Request No. 00420902-01 Address RepairOrprnization. P.O.No..JobNo etc.

3; Work Performed by Byron Mechanical Maintenance -Type Code Symbol Stamp Not Applicable Nan * *Authorization No. Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date Not Applicable, Address

4. Identification of System VQ
5. (a) Applicable Construiction Code Section III 19 71 Edition, W73 Addenda, 1682 Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components National .. Raed. ASME Na otr Manuiacuma - boue Oere Year . ReplSed.C S Fed Cd nudacturn Serial No. No Ideaifliculion Bulk or Rep eeat (YesorNo)

EQUALIZATION JAMESBURY NC17016-02R N/A EPN IVQ5001A 1975 REPLACED, YES VALVE CORP .: ;_.

EQUALIZATION JAMESBURY NC17016-02S N/A EPN I VQ5001 A 1975 REPLACEMENT YES VALVE CORP - . - _ . .

THREADED ROD CHICAGO N/A .N/A EPN I VQ5001 A 1977 REPLACED NO BRIDGE & IRON THREADED ROD NOVA MACHINE HT: 7404456 N/A EPN IVQ5001A 2002 REPLACEMENT NO 4

  • PRODUCTS CODE: F469 .

HEAVY HEX CHICAGO N/A N/A EPN IVQ5001A 1977 REPLACED NO NUTS BRIDGE &IRON . ._._-_._:

HEAVY HEX NOVA MACHINE HT: 83038 N/A EPN IVQ5001A 1997 REPLACEMENT NO NUTS (15) PRODUCTS CODE: FBG _ _.

7. Description of Work REPLACE VALVE AND FLANGE BOLTING - IVQ5001A
8. Test Conducted: Hydrostatic El Pneumatic r Nominal Operating Pressure 0 Appendix J Leak RateTest Other Q Pressure 45.6 psi TestTemp. Ambient °F Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This frm bas been electronially generated.

FORM NIS-2 (Back)

Remarks WO# 00420902-01 0 9. Applicable Manufacturer's Data Reportsto be anshW.ed CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. __ ,

Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed

\~~

6~ ~~~~

'.u '

(9 Date ii j.r ,20 23 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. have inspected the components described in this fwner's Report during the period to , and state that to the best of my knowledge and belief, the Ofteif has performed examinations and taken co rective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Datef f ~f~99,20

~Commissions Date 71OlI- Z6S 20 b73

I

- .-. '. w1 11n

.~~~~~~~~~~~~~~3

.I .  ; . .~ ~ ~ . PA5 .

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions' of the ASME Code Section XI

1. Owner Exelon Nuclear Date Art 1. n hoe UY/ I ul  : I Namne 4300 Winfield Rd. Warrenville, II. 60555 Sheet I of I AddIress 2.. Plant. Byron Nuclear Power Station Unit 01 Narne 4450 N. German Church Road, Byron, 11. Work Order No. 99285124-01 Address . Repair Organization, P.O. No., Job No., c
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Nane - Authorization No. Not Applicable 4450 N. German Church Road, Byron, Il. Expiration Date Not Applicable Address
4. Identification of System WE - Aux. Building Equipment Drains 5.. (a) Applicable Construction Code Section III 19 74 Edition, s75 AddendaN/A - Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacement Components 1989
6. Identification of Components Repaired or Replaced and Replacement Components

. PIPE, 3 IN.,

PIPE, 3 IN.

Nalm

-' of

~~N~~~~of EXELON Narm I

~~~~National t'~~~~~~~antof o .).4ami~~~~~~aetwer Component HUNTER CORP.

~ Serlal~~~~~o.

HT 143805 HT B25985 ut m .

N/A N/A

.BoardNo j

-- _-.other j 5~~dewificatmy IWER7AA IWER7AA ea ear Buth 1983 2002 I -Repafed..

.Replaced.

or Replacement lREPLACED 1REPLACEMENT

[INO I

INO Code ASME (YesStarrqped or No)

SWAGE NIPPLE, HUNTER CORP H-T AHKN N/A .. .IWER7AA 1983 . REPLACED NO 3X2__ _ _ _ __ _ _ _ __ _ _ _ _

SWAGE NIPPLE, EXELON HT75IZNF2 N/A IWER7AA 2002 REPLACEMENT NO 3X2 -_______ ________ _________

S.W. 90 DEG. HUNTER CORP. HT M240 N/A IWE82AA 1983 REPLACED NO ELBOW, 2 IN. . . ._.

S.W. 90 DEG. EXELON HT 75187 N/A IWE82AA 2002 REPLACEMENT NO ELBOW, 2 IN. . _ . _.

PIPE, 2 IN. HUNTER CORP HT AA N/A IWE82AA 1983 REPLACED NO PIPE,2 IN . EXELON HT 720254 N/A IWE82AA 2002 REPLACEMENT NO GLOBE VALVE, ANDERSON S.N. A473 N/A IWE0I0A 1978 REPLACED YES 2 IN. GREENWOOD GLOBE VALVE, ANDERSON S.N. Al615 N/A IWE010A 1979 REPLACEMENT YES 2 IN. GREENWOD

7. ' Description of Work REPLACE PIPING AND VALVE
8. Test Conducted: Hydrostatic [ Pneumatic D Nominal Operating Pressure 3 Other 0 Pressure 98 psi Test Temp. 72 OF Note:* Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet'is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

Remarks Replacement per Work Order 99285124-01.

ApplicabeMa1nuiciurcr's DataReports to be attached

  • -<9, c -rioA)FT C069- (UseG A)-46-1 I
1 ev(1111v ,e;,- I I

I I

I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. reparMtso-Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed Gvc;2d OaS LtA an T k Date 4-3° 20 I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspecte) thepomponents described in this Owner's Report during the period / to 4 3 f ,and state that to the best of my knowledge and belief, the0 ner has performed examinations and taren 06rrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any mannerfor any personal injury or property damage or a loss of any kind arising from or connected with this insptec.o.

C omm issions j/ /ez 2y Hi End Date ik Am0 20NIC Nallon Province iword sag Date ,f30 s20 OZ~

a.

f /,Ic 3/, /1(/D FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 8115/02 Narne

.nr  %-:_e, 1 ] m] A .r..... .V. en -

40UU Winfiela Ru. warrenville, II. ou6 -

Sheet I of 2 Address -

2. Plant Byron Nuclear Power Station Unit 01 Narne 4450 N. German Church Road, Byron, Il. Work Order No. 9928512501 Add"ss - - Repair Organization, P.O. No.. Job No., etc
3. Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Namre Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. Expiration Date Not Applicable Addrms 4.- Identification of System WE - Aux. Building Equipment Drains
5. (a) Applicable Construction Code Section III 19 74 Edition, s75 AddendaN/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89
6. Identification of Components Repaired or Replaced and Replacement Components Nalm of I Naeof I M cterBoard mi Natiomt1 Othetr r ear Repared, IRel)ced.,

.ASME Code; Stamped Manufacturer

_ _ _ _ _ _ _ _ _ _ _ _ _ S~~~~~~~~riiI~~

o [ No l~dentifcat ali or Replacerriem (Yesor N o)

PIPE, 3 IN. HUNTER CORP. HT# 143805 - N/A .I I WER7AB 1984 REPLACED SCH.

SCI14040 4-4 4. IWER7AB 4...4 NO I NO PIPE, 3 IN. CONSOLIDATED I HT# B25985 N/A I. I WER7AB _ 2001 REPLACEMENT NO POWER SUPPLY I,.

SWAGE NIPPLE, HUNTER CORP HT#AHKN N/A IWER7AB 1984 REPLACED NO 3X2 .

SWAGE NIPPLE, 3X2: _- __ :

COUPLING CONSOLIDATED HT# 751 ZNF2 POWER SUPPLY ,

HUNTER CORP. HT #BNO2 N/A N/A

]WER7AB IWE82AB 2002 1984 REPLACEMENT REPLACED NO NO I.

2", 3000#

COUPLING CONSOLIDATED HT # 297YNB N/A IWE82AB 1997 REPLACEMENT NO 2" POWER SUPPLY PIPE,2 IN. HUNTER CORP HT#AA N/A 1WE82AB 1984 REPLACED NO SCH.80 PIPE, 2 IN CONSOLIDATED HT# 698754 N/A IWE82AB 2000 REPLACEMENT NO SCH.80 POWER SUPPLY GLOBE VALVE, ANDERSON A4474 N/A . IWE01OB 1978 REPLACED YES 2 IN. GREENWOOD I-GLOBE VALVE,. ANDERSON S/N AI 334f N/A IWEOJOB

  • 1978 REPLACEMENT YES 2 IN. GREENWOOD is
7. Description of Work REPLACE PIPING AND VALVE
8. Test Conducted: Hydrostatic 5 Pneumatic D Nominal Operating Pressure -

Other 0] Pressure : 9h, psi Test Temp. 7-2 OF Note: Supplemental sheets in form of lists, sketches, or drawings may belused, provided (1) size is 8-1/2 in. x 11 in.,.

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NIS-2 (Back)

9. Remarks Work Order 99285125-01.

ApplacabheManufactum's Data Reports to be attachni ZZX/A/17:5_ eRe,:5;1_4VeAy1f (4,"Ple V Alllelfdla galye. . .

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. r& mpa Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed 6 A A&U, Date /O -,20 0 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. have inspected the components described in this Owner's Report during the period _to_ to 1../e&17, and state that to the best of my knowledge and belief, the Ownrr hds performed examinations and takfn corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

_ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Commissions -

I.Y.r. S;ae

'l N.-a  % ..

. SWB. .,e Gahdo .U Date ,20 o

r FORM NIS-2 SUPPLEMENTAL SHEET

1. Owner Exelon Nuclear Sheet 2 of 2 4300 Winfield Rd. Date 08/15/02 Warrenville, Illinois 60555 Unit 01
2. Plant Byron Nuclear Power Station Unit 01 4450 N. Greman Church Road

- ByronIllinois 61010 99285125-01*

P.O. No., WO No., etc.

3. Work Perforned by: Exelon Mechanical Maintenance Type Code Symbol Stamp NOT APPLICABLE Name Authorization No. NOT APPLICABLE 4450 N. German Church Road. Byron, IL Expiration Date NOT APPLICABLE Address
4. Identification of System WE - Aux. Building Equipment Drains Sa. Applicable Construction Code SECTION 111 1974 Edition s75 Addenda Code Cases N/A 5.b Applicable Edition of Section XI utilized for Repairs or Replacement Components. 19 89 Edition NO Addenda
6. Identification of Components Repaired or Replaced and Replacement Components.

ASME National Ntional .1 . ASME I Nvrc of Name of Manufactre Other Year Replaced. CDI* SWZPCd to I Wr n M nu a bla ulrfrr i No.

Bucad

n. I -

n f iN O., fl U!!'i an ----- -- I1T Oll~ ~

T NlO Ke^ }

Elbow, 3", Sch.40 Hunter Corp. Ht. 1#AW6Z N/A IWER87AB 1983 Replaced N/A Elbow, 3-;Sch.40 Exelon^ HJ194A N/A I WER87AB 2002 Replacement NA (Final)

I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions or the ASME Code Section XI Owner Exelon Nuclear Date' 02/25/02 Name 4300 Winfield Rd. Warrenville, Il. 60555 Sheet I . of I Address

2. Plant Byron Nuclear Power Station Unit 01 Narne 4450 N. German Church Road, Byron, 11. Work Request No. 99215439-04 Address Repair Organization. P.O. No., Job No., etc.

3.- Work Performed by Byron Mechanical Maintenance Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable 4450 N. German Church Road, Byron, 11. 'Expiration Date Not Applicable Address

4. Identification of System (XX) Spare Valve
5. (a) ApplicableConstruction Code Section 11I 19 74 Edition, s/7 Addenda, e Code Case I (b) Applicable Edition of Section Xl Utilized for Repairs or Replacement Components 19 89 6.' Identification of Components Repaired or Replaced and Replacement Components Nationsl Repafied, .. ASME Name of Nane or Manufacturer board Otaer Year Replaced. Code; StaWed Co.1o ea Manufacuer Serial No. No . Identification Bul or Replaceoerti fesorNo):

SUB-ASM. JAMESBURY HT# 1844X .

SHAFT/WAFER . HT CODE PLP-1 N/A CAT ID #6541 1986 REPLACEMENT NO WAFER JAMESBURY CTM-2

.__________.____. ___. _ N/A 1978 REPLACED NO

7. Description of Work REBUILD SPARE VALVE
8. Test Conducted: Hydrostatic E Pneumatic D Nominal Operating Pressure 0 AVA Other Q Pressure psi Test Temp. OF Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x 11 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronially generated.

FORM NIS-2 (Back)

9. Remarks This NIS-2 is for rebuilding of a spare valve per WO 99215439-04. Valve installation into the plant will be per a different WO.

Applicable Manufacturer's Dats Reponts to beattacned I

I I

I I

I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this go eE*fE7U St conforms to the rules of the ASME Code, I Section Xl. ripaira rplarmea Type Code Symbol Stamp NOT APPLICABLE Certificate of Authorization No. NOT APPLICABLE Expiration Date NOT APPLICABLE Signed f"-1 a k.it... Date 11.7 ,20 02- I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILLINOIS and employed by H.S.B. CT of Hartford, CT. have inspected the components descnbed in this Owner's Report during the period / grz to '76/3 , and state that to the best of my I knowledge and belief, the Owner has performed examinations and takerf c rective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions_ _ _ __ _ _ _ _

Inor's~ ~~~~~~~~~~~~~~1-s NWno...

I Date ~ 20 .03 I

r FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Exelon Nuclear Date 9/22/03
  • Name .I 4300 Winfield Rd. Warrenile. _..60555 Sheet 1 of - I Address I
2. Plant Byron Nuclear Power Station Unit

_. . 0 4450 N.Gra hrhName 4450 N. German Church Road, Bvron, II. York Reauest No. 99260291-01 '

.. . . .. Address -. - Rpair Orranization. P.O. No., Job No, etc.

3. Work Performned by Byron Mechanical Maintenance -Type Code Symbol Stamp Not Applicable Nam .
  • Authoriiation No.-Not Applicable 4450 N. German Church Road, Byron, II. Expiration Date 'Nsot Applicable Address
4. . Identification of System Spare Valve Assembly .
5. (a) Applicable Construction Code Se'cion II] 19 86 Edition, 1987. AddendaNO Code Case

- - - - 1974 Editiqn, S757Adenda (piping)

  • (b) 'Applicable Ediiion of Section X1 Utilized for Repairs or Replacement Components 19 89.
6. Identification of Components Repaired or Replaced and Replacement Components -

Nau o. asor .*

Natiomi

~~~~~~~~~Repairvd, ASME

~~~~~~Non of Manu fbn urax

§ boon! Otbr Year . Repeied. Coe AStu£

'Coa~opo Msoufacnrwer . Seri No. - .. -o Idestificntion Buli or Replaem (Yes or No) 2" GLOBE KSB S/N #190884/12 CAT ID #34598 Replacement YES VALVE -

  • N/A --- - 1990 . .

2" PIPE Consolidated HT #070037 NIA - CAT ID #27431 . 2002 Replacement NO I I

. Power Supply ._.;__.__,._'._

7. Description of Work INSTALL PIPE STUBS INTO VALVE BODY - SPARE ASSEMBLY
8. Test Conducted: Hydrostatic El Pneumatic 13 Nominal Operating Pressure 0 N/A ' .

Other a Pressure _ _psi Test Temp. °F Note: Supplemental sheets in form'of lists, sketches, or drawings may be used, provided (I) size is 8-1/2 in. x II in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form has been electronically generated.

FORM NJS-2 (Back)

  • Remarks Testing to be performed when installed into the plant under applicable WO. 0 1 1 1 0 . 9. Applicable Manufactwens Datlarqpons to be-atahe Invoked Code Case N416-l WO 99260291-01 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol 'Stamp NOT APPLICABLE Certificate ofAuthorizationNo. NOT APPLICABLE Expiration Date NOT APPLICABLE

.Signed . Date z q ,20q3 CERTIFICATE OF INSERVICE INSPECTION

.1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the' State or Province of ILLINOIS and employed by H.S.B. CT.

of Hartford, CT. - have inspected the components described in this O)wner's Report during the period S,5/dlj,3 to 4 s1, and state that to the best of my knowledge and belief, the Owner'has performed examinations and taken co rective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ C omm issions -7 59 Date e , 20 03