ML21214A149

From kanterella
Revision as of 23:33, 17 August 2021 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

License Amendment Request: Request for Additional Information
ML21214A149
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 08/02/2021
From: Shilpa Arora
Plant Licensing Branch III
To: Offerle M
DTE Electric Company
Arora S
References
EPID L-2021-LLA-0057
Download: ML21214A149 (2)


Text

From: Arora, Surinder To: Margaret M Offerle Cc: Wiebe, Joel; Salgado, Nancy

Subject:

Fermi 2 - License Amendment Request: Request for Additional Information (EPID L-2021-LLA-0057)

Date: Friday, July 23, 2021 10:33:00 AM Attachments: Fermi 2 RAI (EMIB dated 7-21-2021) SA.docx Ms. Offerle, By letter dated March 31, 2021 (Agencywide Documents Access Management System (ADAMS) Accession No. ML21090A194), DTE Electric Company (DTE, the licensee) submitted for the NRC staff review and approval the proposed revisions to Fermi 2 technical specification to remove some obsolete information, make minor corrections, and make miscellaneous editorial changes.

The U.S. Nuclear Regulatory Commission (NRC) staff is reviewing the above request and has determined that response to the attached request for additional information (RAI) is needed from DTE to complete its review. Please review the attached RAI to ensure that the staffs question is understandable, the regulatory basis is clear, and there is no proprietary information contained in the draft RAI. Please also let me know if DTE wishes to have a clarification phone call and how much time you will need to respond to the RAI. Our default response schedule will be 30 days from the date of this email unless we hear from you otherwise.

Thank you, SURINDER ARORA, PE Project Manager, Fermi 2 NOTE: In the Clarification Call on US NUCLEAR REGULATORY COMMISSION July 29, 2021, the licensee OFFICE OF NUCLEAR REACTOR REGULATION (NRR) confirmed that there was no DIVISION OF OPERATING REACTOR LICENSING (DORL) need to resend the final RAI.

Plant Licensing Branch III (LPL3) Since no change is needed as a result of the clarification call, Phone: 301 415-1421 they can work with this version Email: Surinder.Arora@nrc.gov that they already have.

Docket No. 50-341 EPID: L-2021-LLA-0057

REQUEST FOR ADDITIONAL INFORMATION PROPOSED LICENSE AMENDMENT TO REVISE TECHNICAL SPECIFICATION 3.5.4.1.c FERMI NUCLEAR GENERATING STATION, UNIT 2 DTE ELECTRIC COMPANY DOCKET NO. 50-341

References:

1. Letter dated March 31, 2021 (Agencywide Documents Access Management System (ADAMS) Accession Number ML21090A194) from DTE Electric Company, proposing revisions to Fermi 2 technical specifications (TS) to remove some obsolete information, make minor corrections, and make miscellaneous editorial changes.
2. Fermi 2 technical specification (ADAMS Accession No. ML053060228).
3. NUREG-0667, Probability of the Intersystem LOCA: Impact Due to Leak Testing and Operation Changes, (ADAMS Accession No. ML19323E667).

The NRC staff has reviewed the Fermi 2 license amendment request (Reference 1), specifically, the proposed change to TS surveillance requirement (SR) 3.4.5.1.c, and requires the following additional information to complete its review:

EMIB-RAI-1:

The amendment request proposes a change in the wording of SR 3.4.5.1.c for isolation check valves (E1100F050A and E1100F050B) from the term testable check valves to just valves.

The current TS 3.4.5 uses description of these isolation valves as check valves. The NRC staff also reviewed the Fermi 2 TS Bases, the Inservice Testing (IST) Program, and the NRC approved Alternative Request No. RR-VRR-003 (ADAMS Accession No. ML20014E731) and found that all these documents describe these isolation valves as testable check valves.

Furthermore, the Fermi 2 TS Bases 3.5.4 states, in part, that A study (NUREG-0677) evaluated various PIV configurations to determine the probability of intersystem LOCAs. This study concluded that periodic leakage testing of the PIVs can substantially reduce intersystem LOCA probability. This study cited in NUREG-0677 only considered check valves, for evaluation.

Therefore, NRC staff considers the proposed change to be inconsistent with the terminology used in other documents and these isolation valves should be check valves instead of just valves.

Based on the above, please justify the proposed change to SR 3.4.5.1.c which changes the term testable check valves to just valves.