ML20216E261

From kanterella
Revision as of 05:20, 6 March 2021 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Monthly Operating Repts for Feb 1998 for South Texas Project Electric Generating Station,Units 1 & 2
ML20216E261
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 02/28/1998
From: Hill R, Mcburnett M
HOUSTON LIGHTING & POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NOC-AE-000108, NOC-AE-108, NUDOCS 9803170454
Download: ML20216E261 (14)


Text

r Nuclear Operating Company I EW E Y sgasu m mswgamecm m au m n w m m. arm s m March 10,1998 NOC-AE-000108 l File No. G02 STI30564719 10CFR50.71 l

U. S. Nuclear Regulatory Commission l Atiention: Document Control Desk

[ Washington, DC 20555 l

South Texas Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Monthly O.oeratine Reoorts for February 1998 l Pursuant to 10CFR50.71(a) and South Texas Project Electric Generating Station l (STPEGS) Technical Specification 6.9.1.5, attached are the Monthly Operating Reports for l February 1998.

If you should have any questions on this matter, please contact T. E. Underwood at (512) 972-7108.

l Sincerely, b

M. A. McBurnett Director, Nuclear Licensing RLII/sl l Attachments: 1) STPEGS Unit 1 Monthly Operating Report - February 1998 l 2) STPEGS Unit 2 Monthly Operating Report - February 1998 D

/

l 9803170454 DR 980228 ADOCK 05000498 PDR

^

kkk,kkhk,kkhk j

s .

ST-NOC-AE-000108 File No.: G02

, Page 2 Ellis W. Merschoff Jon C. Wood Regional Administrator, Region IV Matthews & Branscomb  !

U. S. Nuclear Regulatory Conunission One Alamo Center 611 Ryan Plaza Drive, Suite 400 106 S. St. Mary's Street, Suite 700 Arlington, TX 76011-8064 San Antonio,TX 78205-3692 1

Thomas W. Alexion Institute of Nuclear Power Project Manager, Mail Code 13H3 Operations - Records Center U. S. Nuclear Regulatory Commission 700 Galleria Parkway Washington, DC 20555-0001 . Atlanta, GA 30339-5957 David P. Loveless Richard A.Ratliff Sr. Rerident Inspector Bumau of Radiation Control c/o U. S. Nuclear Regulatory Connaission Texas Department of Health P. O. Box 910 1100 West 49th Street Bay City, TX 77404-0910 Austin, TX 78756-3189 J. R. Newman, Esquire D. G. Tees /R. L. Balcom i Morgan, Lewis & Bockius Houston Lighting & Power Co.

1800 M. Street, N.W. P. O. Box 1700 Washington, DC 20036-5869 Houston,TX 77251 M. T. Hardt/W. C. Gunst Central Power and Light Company City Public Service ATrN: G. E. Vaughn/C. A. Johnson ,

P. O. Box 1771 P. O. Box 289, Mail Code: N5012 San Antonio,TX 78296 Wadsworth,TX 77483 A. Ramirez/C. M. Canady U.S. Nuclear Regulatory Commission City of Austin Attention: Document Control Desk Electric Utility Department Washington, DC 20555-0001 721 Barton Springs Road Austin,TX 78704

[:

l l

I l

l 1

SOUTH TEXAS PROJECT

!' ELECTRIC GENERATING STATION i

i UNIT I

, MONTHLY OPERATING REPORT l

FEBRUARY 1998 l

STP NUCLEAR OPERATING COMPANY NRC DOCKET NO. 50-498 LICENSE NO. NPF-76 l

Reviewed By: %M O 3/E/96 T.E. UNDERWOOD Date Approved By: - //f/f/

G'L. PARKEY I Dkte' l

MONTIILY

SUMMARY

Sputh Texas Project Unit 1 operated during the reporting period at full power with no unit shutdowns or significant power reductions.

l l

l l

l l

OPERATING DATA REPORT f

l DOCKET NO. 52:128 UNIT 1 DATE Mar. 5.1998 COMPLETED BY R.L Hill TELEPliONE 512 972-7667 OPERATING STATUS l

l 1. REPORTING PERIOD: 2/1/98-2/28/98 GROSS HOURS IN REPORTING PERIOD: 612

2. CURRENTLY AUTIIORIZED POWER LEVEL (Mwt): 33.QQ MAXIMUM DEPENDABLE CAPACITY (MWe-Net): 1250.6 DESIGN ELECTRICAL RATING (MWe-Net): 1250.6
3. POWER LEVEL TO WHICH RESTRICTED (IF ANY) (MWe-Net): Nanc
4. REASONS FOR RESTRICTION (IF ANY): N/A l THIS MONTil YR TO DATE CUMULATIVE
5. NUMBER OF llOURS REACTOR CRITICAL 622& l.416.0 59.452.1
6. REACTOR RESERVE SHUTDOWN HOURS Q Q Q
7. 1IOURS GENERATOR ON LINE 622A 1.416.0 57.990.9
8. UNIT RESERVE SHUTDOWN HOURS Q Q Q l 9. GROSS TIIERMAL ENERGY GENERATED (MWH) 2.564.932 5.404.506 214.722.097
10. GROSS ELECTRICAL ENERGY GENERATED (MWH) 882.490 1.859.147 73.218.711 l

l

11. NET ELECTRICAL ENERGY GENERATED (MWH) 846.774 1.784.552 69.697.298
12. REACTOR SERVICE FACTOR lakQ% 100.0 % 2Ll%
13. REACTOR AVAILABILITY FACTOR 100.0 % 100.0 % 2L3%
14. UNIT SERVICE FACTOR 100.0 % 100.0 % 611%
15. UNIT AVAILABILITY FACTOR 100.0 % 100.0 % 611%
16. UNIT CAPACITY FACTOR (Using MDC) 100.8 % 100.8 % 663 %
17. UNIT CAPACITY FACTOR (Using Design MWe) 100.8 % 100.8 % 663 %
18. UNIT FORCED OUTAGE RATE D&% Q&% 2DJ%
19. SHUTDOWNS SCliEDULED OVER NEXT 6 MONTilS (TYPE, DATE, AND DURATION OF EACil):

j N/A

20. IF S11UTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: N/A

(

l l

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-498 UNIT 1  ;

DATE Mar. S.1998 j COMPLETED BY R.L. Hill l TELEPHONE 512 972-7667 MONTH FEBRUARY l

DAY AVERAGE DAILY POWER DAY AVERAGE DAILY POWER LEVEL LEVEL (MWe-Net) (MWe-Net) 1 12fiQ 17 12fiQ 2 12fil 18 12fil 3 12fiQ 19 12fi2 4 12fil 20 1211 5 12fiL 21 12EE 6 12fiQ 22 1251 7 12fiQ 23 12fi2 8 12fiQ 24 12fiQ 9 1252 25 12fil 10 1251 26 12fiQ l1 1252 27 12fiQ l

12 12fiQ 28 12fiQ 13 12fiQ 29 N/A 14 12fil 30 N/%

15 12fil 31 N/A 16 12fil I

l L

e c

7 n 2

- 9 6

6 7-e r

r

- u

'.' c

_ 1 9

7 e D 4- r

. R O a 2 t I

_ 4 JIM5W9 1 5

n e

v e

R E

P 3 8

r 9 OI.TEYE P G 1 NN A TBN o t

N I 3 T U D DE O n T 0 E H P o R 8 K l i

t O E i E c P E C t L L A E E O P TE e R 5I D M i t

v E

H O c e

C r r T o G C N I

_ R 3 8

e s U 9 u

a D 1 S 5

_ C N 0 8

O E S I T E N C 4I E

O t i

i U

I T

5 c,

-.e D E

C 6d po R U iC r R D

i o E E Y -C W R R O A 4 P R_ U me E R ed T mg B t s o N . n W E yC A i

i.

.i t s s O F S C i.Si P i F cc x SiE n D H I 3

t af o N

o e

aam.gemr l l i T #  :

N N et s nt r G d onn uu ot e

- A O ne evp o I

S h a a uot t

nah_h~ t

_ S M i cEe R t

eMMACuRO O-59 N T . L R O M1- -234 - -

R

. W O 3 f S

N O P E

og r W

D R d nno otiwt c O T ht u oa t

D m U ehDe R T a

x H

S MS U E H )

n e s )

T 2 S

ia n n I n o T l p

e c

i a

- N s I

N x nL i

lp U a e U E

( t o E x

R O ee s i&

t c (

rT ir g r N u r t n o ener r )n si l

n E R

i ao RivEi a io )s t

r u E F e t c y r t ai l l aa p a o r nn eagrTr nx uH W nnt oi soE ort i(

D( E mel pt el i

at n t

_ R :nin uif ge u urairar meh e E o qa ee pd pt s

H aEMRROA e T e - - - - - - OO -

_ I p 2RABCDEFGH y

- T D

t e

a d

l e

dedu ce rh

_ o oc fS N . :

1 FS

l PORVS AND SAFETY VALVE

SUMMARY

There were no PORV or Safety Valves challenged during the reporting period.

I i

i l

N 1 1 1

\

SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 2 MONTHLY OPERATING REPORT i

FEBRUARY 1998 i STP NUCLEAR OPERATING COMPANY j NRC DOCKET NO. 50-499 q LICENSE NO.NPF-80 l

l Reviewed By: M d-- -

3/s)3%

T.E. UNDERWOOD Date Approved By: [d A / 8 f TP R.E. MASSE [ D' ate i

5 l

i i

l l

I

r l

i i .

t .. .

l MONTHLY

SUMMARY

i South Texas Project Unit 2 operated during the reporting period at full power with no unit shutdc,wns or significant power reductions.

l l

l 1

I I

l

OPERATING DATA REPORT DOCENT. 50-499 UNIT 2 DATE Mar. 5.1998 COMPLETED BY R.L. Hill TELEPHONE 512 972-7667 OPERATING STATUS

1. REPORTING PERIOD: 2/1/98-2/28/98 GROSS HOURS IN REPORTING PERIOD: 622
2. CURRENTLY AUTHORIZED POWER LEVEL (Mw1): .31DQ MAXIMUM DEPENDABLE CAPACITY (MWe-Net): 1250.6 DESIGN ELECTRICAL RATING (MWe-Net): 1250.6
3. POWER LEVEL TO WHICil RESTRICTED (IF ANY) (MWe-Net): Nnaq
4. REASONS FOR RESTRICTION (IF ANY): N/A THIS MONTH YR TO DATE CUMULATIVE
5. NUMBER OF HOURS REACTOR CRITICAL fi22.0 1.416.0 56.207.4
6. REACTOR RESERVE SHUTDOWN HOURS Q Q Q
7. HOURS GENERATOR ON LINE 622.0 1.370.4 54.658.6
8. UNIT RESERVE SHUTDOWN HOURS Q Q Q
9. GROSS THERMAL ENERGY GENERATED (MWH) 2.564.932 5.223.855 202.567.364
10. GROSS ELECTRICAL ENERGY GENERATED (MWH) 880.361 1.786.271 68.951.250
11. NET ELECTRICAL ENERGY GENERATED (MWH) 845.509 1.714.766 65.794.943
12. REACTOR SERVICE FACTOR I00.0 % 100.0 % 23 2 %
13. REACTOR AVAILABILITY FACTOR 100.0 % 100.0 % 22.2%
14. UNIT SERVICE FACTOR 100.0 % 2fil% 2L2%
15. UNIT AVAILABILITY FACTOR 100.0 % 26 3 % 2L2%
16. UNIT CAPACITY FACTOR (Using MDC) 100.6 % 261 % 62.0%
17. UNIT CAPACITY FACTOR (Using Design MWe) 100.6 % 2filh 62.0%
18. UNIT FORCED OUTAGE RATE Q.Q% 2.2% 12.1 %
19. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):

l N/A

20. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: N/A i

l I

)

i l

l l ..

AVERAGE DAILY UNIT POWER LEVEL l DOCKETNO. 50-499 l .

UNIT 2 DATE Mar. 5.1998 l COMPLETED BY R.L. Hill TELEPHONE 512 972-7667 l MONTH FEBR11ARY

! DAY AVERAGE DAILY POWER DAY AVERAGE DAILY POWER

! LEVEL LEVEL (MWe-Net) (MWe-Net) 1 1218 17 1212 2 1211 18 1212 3 1212 19 1212 4 1216 20 1218 5 1251 21 126D l

l 6 1212 22 1212 7 1212 23 1260 l 8 1212 24 1212 l- i 9 1218 25 1218 l

l 10 1212 26 1212

Ii 1214 27 1260
12 1216 28 1260 t

13 1212 29 N!%

14 1251 30 N/A i

l 15 1212 31 N!% l l 16 12it l

e 7 c 8 6 n 9 6 e r

9 7 r 1 i-d2 u 9 . c 9

5 H79 R e

4- r 0

a L. 21 t n

52MR5 e v 3 e

r 8

9 OI.TEYE P D 1 NN TU A TBN t o O I

3 0

DD n E EO H o R E

8 K TP E E it c P E E

C L L A G E O P E 5I D e v N MT i t

I T

O c e R C r r O o P C E R

& E 3

8 e

s 1 9 1

u 1 1

a 5 C G 0 N

I 8

S R E U E N E O t D 4I n

5 e n S n

ne N t od po O U mC I

T D o C E Y C U R R D A E R U 4 me R .

E R ed R i g

-n W B t s o E .

E yC uti s O F S W .Si x P H O

P uct SiE n o

D T e 3 l l af o N et

  1. T  : aa uu m.gu ec it N s nt r N d onnt ot nad h e r

A O neo evp A h a a uot et S M i cEe C t eMMACuRO O-59 N T L R I F M1- -234 - -

R I N

W O 3 f G

O P og r I D E dotiwtnno S T R t c R h u oa m U t ehDe R O a x

H S

MS S N

E

) e W n s )

T 2 n i

a n e i n

I o O l c a N s D p

x nL i

l p

U a e T E o E x

R U ( ts ee ic&

t (

H r i r e r S

T luTr t sk e ner r)n o

n I ia o RivEi a io )r s u

N F e c y ai r t l l p

t a

r o U t

e nn agrTaa or r t nx D(

uH O melnntati oi nt s ioE (

N :nin pt el u urair a

re I

E uif ge o qa e e pd pt meh R s I

e E aEMRROAOO e - - - - - - --

p y W 2RABCDEFGH T E R

E H

_ T

- e t

a D d le dedu c

rh e

o oc FS N  : : _

1 FS

PORVS AND SAFETY VALVE

SUMMARY

i i

{

, There were no PORV or Safety Valves challenged during the reporting period. i l

i I

1 l

l l

l

.