05000333/LER-1993-009, Forwards LER 93-009-02 Re Low Rwl Scram Due to FW Transient. Replacement of Reactor Feed Discharge Valves W/Improved Design Scheduled So That One Valve Will Be Replaced During 1994 Refueling Outage

From kanterella
Revision as of 08:35, 26 April 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 93-009-02 Re Low Rwl Scram Due to FW Transient. Replacement of Reactor Feed Discharge Valves W/Improved Design Scheduled So That One Valve Will Be Replaced During 1994 Refueling Outage
ML20076L190
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 10/25/1994
From: Harry Salmon
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20076L192 List:
References
JAFP-94-0514, JAFP-94-514, NUDOCS 9411030061
Download: ML20076L190 (1)


LER-2093-009, Forwards LER 93-009-02 Re Low Rwl Scram Due to FW Transient. Replacement of Reactor Feed Discharge Valves W/Improved Design Scheduled So That One Valve Will Be Replaced During 1994 Refueling Outage
Event date:
Report date:
3332093009R00 - NRC Website

text

~ - -

y 3 Jamn A.FluPatrick

. Noelar Power Plint I P.O. Box 41 l Lycoming, New York 130% l 315 M2-3840

  1. > NewWrkPower . Harry P. Salmon, Jr.

1 l

l. M AUthOrlfy sesident Manager October 25, 1994 l JMP-94-0514 United States Nuclear Regulatory Commission Document Control Desk-Mail Station P1-137 Washington, D.C. 20555

SUBJECT:

DOCKET NO. 50-333 t LICENSEE EVENT REDORT: 93-009 Low Reactor Water Level Scram Due to Feedwater Transient

Dear Sir:

This report was submitted in accordance with 10 CFR 50.73 (ri (2) (iv) , 10CFR50. 73 (a) (2 ) (v) (D) and 10CFR50.73 (a) (2) (1) (B) .

This supplement provides an updated status of the long-term corrective actions related to this event. The replacement of the reactor feed discharge valves with an improved design has been scheduled so that one valve will be replaced during the 1994 Refueling Outage. The second pump discharge check valve will be inspected during the 1994 Refueling Outage and replaced during the 1996 Refueling Outage if supported by the inspection findings.

Questions concerning this report may be addressed to Mr. Donald Simpson (315) 349-6361.

Very truly yours, HARRY P. SALMON, JR.

HPS: D ftlc Enclosure cc: USNRC, Region 1 USNRC Resident Inspector INPO Records Center 9411030061 DR 941025 ADOCK 05000333 PDR l

. . .