ML20087F456

From kanterella
Revision as of 10:25, 14 April 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Form NIS-1, Owners Rept for ISI, for 940513-950509
ML20087F456
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 08/09/1995
From:
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20087F447 List:
References
NUDOCS 9508150288
Download: ML20087F456 (100)


Text

_-

. < - *g FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASN2 Code Rules -

I i

1. Owner Wisconsin Electric Power Company. 231 W. Michigan Ave.. Milwaukee W1 53201 l (Name and Address of Owner) i
2. Plant Point Beach Nuclear Plant. 6610 Nuclear Road. Two Rivers. WI 54241 (Name and Address of Plant)
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) Docket 50-266 l
5. Commercial Service Date 12/21n0 6. National Board Number for Unit N/A i
7. Components Inspected j i

i Component or Manufacturer or Manufacturer State or National i Appurtenance installer or Installer Province No. Board No.

Serial No. )

Reactor Pressure Vessel Babcock & Wilcox R-1 U010615 NB 0138 l

Pressurizer Westingbouse 16A6256-1 0010618 NB 0685 A Steam Generator Westinghouse 16A6339-1 U010616 16A6079-1 B Residual Heat Removal Hx J. A. Oats UO10599 NB 0272 Class 1 Piping System Westinghouse Class 2 Piping System Bechtel ,

Class 2 BOP Piping System Westinghouse i

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this repon is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/86) This form (E00029) may be otxained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007 2300.

95CB150288 950809 PDR ADOCK 05000266 Q PDR

o q ,i';

Sheet 2 of 2 FORM NIS-1 CONTINUED

8. Examination Dates 3/11/95 to 4/19/95 9. Inspection Interval from 5/13/94 to 5/9/95
10. Applicable Editions of Section XI 1986 Addenda None
11. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interva'.

Refer to attached Inservice Inspection Final Report, Section 2.0. ,

12. Abstract of Conditions Noted.

Refer to attached Inservice Inspection Final Repon, Section 3.0.  ;

13. Abstract of Corrective Measures Recommended and Taken.  ;

Refer to attached Inservice Inspection Final Report, Section 3.0.

We cenify that the statements made in this repon are correct and the examinations and corrective measures taken conform to the mies of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) NRC Docket 50-266 Expiration Date N/A Date V

k 19 M Signed Wisc. Electric Power Co. By Owner d!

CERTIFICATE OF INSERVICE INSPECTION ,

I, the undersigned, holding a valid commission issue.1 by the National Board of Boiler and Pressure Vessel )

Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. i Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss f any kind arising from or connected with this inspection, b Commissions lO75l r M 7Y r 5 &'b '

Insperfor's Sig5(ure National Board, State. Province, and Endorsements Date fAs< ss k 9 19 W l

)

i i

Wisconsin Dectne Power Ca.

D? '

231 West Michigan Avenue Milwaukee, WI 33201 Point Beach Nuclear Plant, Unit 1 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-266 CommercialService Date 12/2100 i

l l

t UNIT 1 REFUELING 22 l

INSERVICE INSPECTION

SUMMARY

REPORT FOR FORM NIS-1 Written by: 4 A' Date: 0~ ~

Reviewed by: A b Date: 8- f- 9 F Approved by: N Date: I' '[

l

L-1- - i '

> :-L * --, Wisconsin Electnc Fower C3.

231 West Michigan Avenue  ;

Milwaukee,WI 53201: ,  !

Point Beach Nuclear Mant,' Unit 1 6610 Nuclear Road -

= Two Rivers, WI 54241 Docket 50-266 ,

Conunercialservice Daae 12/2100 l

Acronyms l

(- ASME American Society of Mechanical Engineers ,

CCW' Component Cooling Water >

- CR Condition Report EBASCO Raytheon-EBASCO Services Incorporated IDR Indication Disposition Report IN Information Notice -

i ISI Inservice Inspection l

LTP Long Term Plan  !

MT Magnetic Particle Examination MWR Maintenance Work Request 4 MR Modification Request NDE Nondestructive Examination NES Nuclear Engineering Section I

- NRC Nuclear Regulatory Commission

- PBNP Point Beach Nuclear Plant l l

P-G Phillips Getschow l PT Dye Penetrant Examination i PWA Professional Welding Associates QTS Quality Technical Services RT. Radiographic Examination Page 2 of 20

4 Unconsin Bectnc Power C3,

..- 231 West Michigan Avenue Milwaukee,WI $3201 Point Beach Nuclear Plant, Unit I 6610 Nuclear Road Two Rivers, WI 54241 i Docket 50-266 i CommercialService Date 12/2100 -l RRM Repair / Replacement / Modification .

\

UT Ultrasonic Examination i VT Visual Examination i

WE Wisconsin Electric Power Company. l l

l

)

l l

i l

j i

i I

I l

l 1

Page 3 of 20 i

=; , ,

s yJ b ,

Wisconsan Elecaic Power C2.

-a 231 West Michigan Avenue -

Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit i 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-266 Commercialservice Dane 12/21/70 Table of Contents

1.0 INTRODUCTION

2.0 ABSTRACT OF EXAMINATIONS 2.1 Code Cases and Interpretations 2.2 Determination of Scope 2.3 Component / Weld Examinations 2.4 Completed Component / Weld Examinations 2.5 Pressure Tests 2.6 Snubber Surveillance Tests 3.0 ABSTRACT OF CONDITIONS NOTED AND CORRECTIVE MEASURES TAKEN 3.1 Component / Weld 3.2 Pressure Tests 3.3 Snubber Surveillance Tests i

Page 4 of 20

e Wisconsin Electric Power Ca.

a' 231 West Michigan Avenue Milwaukee.WI $3201 Point Beach Nuclear Plant. Unit !

6610 Nuclear Road Two Rivers. WI $4241 4 Docket 50-266 ConunercialService Date 12/21no  ;

UNIT 1 REFUELING 22 INSERVICE INSPECTION

SUMMARY

1.0 INTRODUCTION

From May 13,1994 to May 9,1995, non-destmetive examinatioris of selected components at PBNP Unit I were performed. These examinations constitute the second examination of the second period, of the third 10-year interval at PBNP Unit 1. The time interval for this examination period included the Unit 1 Refueling 22 outage (UIR22) that ran from March 11

  • to April 19,1995.

2.0 ABSTRACT OF EXAMINATIONS 2.1 Code Cases and Interpretali.om This report and examinations were completed applying the following:

2.1.1 ASME Code Interpretation, Section VIII-1-83-17, which allows for computer generated data report forms to be used as long as size, arrangement, and content are identical.

2.1.2 Code Case N-460 2.1.3 Code Case N-448 '

2.2 Determination of Scope Components and system areas were selected for examination in accordance with the following:

2.2.1 PBNP FSAR, Technical Specification Section 15.4.2.B 2.2.2 Unit 1 Inservice Inspection long Term Plan for the Third Inspection Interval 2.2.3 NRC IE Bulletin 82-02 2.2.4 Requests of PBNP Personnel Page 5 of 20

[* ; <

f wi-i. sectne Po.er ca.

231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit i 6610 Nuclear Road Two Riven, WI 54241 Docket 50-266 Commercialservice Date 12/21/70 2.3 Scone of Component Examinations Items from the following components and system areas were examined with NDE techniques by WE (QTS), Raytheon-EBASCO, Phillips Getschow (P-G) and Professional Welding Associates (PWA) personnel.  !

Reactor Vessel Pressurizer '

A Steam Generator Residual Heat Removal Heat Exchanger Class 1 and 2 Piping Welds Class 1,2, and 3 Pipe Supports 2.4 Comoleted Component / Weld Examinations 2.4.1 Explanation ofISI Database fields / entries used in NIS-1 report.

CODE or HEADING DESCRIPTION i EXAM The field that defines the requirement or reason that an examination TYPE was performed.

l 86E-03 Examinations performed in accordance with the 1986 Edition, no addenda, of ASME Section XI, for the Third Inspection Interval.

B01-03 Augmented examinations perfonned on Heavy Load Lifting devices in response to ANSI N14.6.

B02-03 Augmented examinations performed on Reactor Coolant Pump Flywheels (Reg. Guide 1.14).  !

B03-03 Augmented Examinations performed on the Main Steam Bypass Line Energy Absorbers B04-03 Augmented Examinations perfonned on Threaded Fasteners in accordance with IEB 82-02. j Page 6 of 20

t 3*l n ,

Wiscomme Elecenc Power Q3 231 West Mrhymn Avenue i=t Milwaukee,wl 53201 Point Beach Nuclear Plant. Unit !

6610 Nuclear Road Two Rivers. WI 54241 -

- Docket 50-266 Conunercialservice Dane 12/2100 f-B07-03 Augmented Examination Performed on Steam Generator Feedwater '

Nozzles in accordance with CR 92-004.

P P19-03 ' Preservice exam for RRM 94-0082.

P20-03 Preservice exam for RRM-94-0083.

l:

-. P21-03 Preservice exam for RRM 95-0003.

R15-03 Re-examination required in accordance with IWA-4500(a), reference IDR 94U1-7P029.

R16-03 Re-examination required in accordance with IWA-4500(a),' reference IDR 94UI-7P037.

R17-03 Re-examination after nework for MWR 9504398, reference IDR 95U1-7P013.

SO4-03 Successive Examination required in accordance with IWF-2420(b),

reference IDR 7-P-004, Outage 02.

X01-03 Supplemental Examination for RPV Closure Nut (RPV-NUT-26).

ll Ind Typ A description of indications (i.e., N = no indications,' R = recordable -

indications, I = insignificant or non-relevant indications, G 1 geometry).

.l Results Indicates the outcome of a particular exam. h P = Pass C = Conditionally Accepted F = Fail N = No examination performed Program Indicates whether ASME Section XI credit (IWX-2410) has been taken Credit for the exam. . Augmented or other examinations not performed for an .i ASME Section XI requirement will be indicated by an N.

Examinations completed for additional, successive, or preservice examination requirements will also be indicated by an N even though they were performed for an ASME Section XI requirement.

2.4.2 Following are database printouts that summarize the ISI examinations that were performed during the Unit 1 Refueling 21 outage.

Page 7 of 20

g Wisconsin Sectne Pow Ca.

231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant, Unit !

6610 Nuclear Road Two Rivers, WI '54241 Docket 50-266 CommercialService Date 12/21/70 i

U1R22 Examinations (Pages 8-1 through 8-36) i I

l l

l I

Page 8 of 20 I

-;]

.. x.

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road

  • Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENTIDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIITION PROGRAM IND TYPE DATE SHEET CREDIT TYP-ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

================================================================================= . --

, 37-04-PS VT-3 86E-03 03/14/95 95UI-754P066 RIGID SUPPORT P Y N N/A ISI-PRI-l137 2.00 0.000 37-09-PS VT-3 86E-03 03/14/95 95UI-754P069 RIGID SUPPORT P Y I N/A ISI-PRI-I137 2.00 0.000 39-16-PSSB VT-3 86E-03 03/14/95 95UI-754P062 RIGID SUPPORT P Y N N/A ISI-PRI-1151 2.00 0.000 40-16-PRA VT-3 86E-03 03/14/95 95UI-754P059 RIGID SUPPORT P Y N N/A ISI-PRI-ll40 2.00 0.000 i

40-20-PSS VT-3 86E-03 03/22/95 95UI-754P074 RIGID SUPPORT P Y N N/A ISI-PRI-1140 2.00 0.000 PAGE 8-1 .

s 2- a Wisconsin Electr*c Power Company Point Beach Nuclear Plant, Unit I

~

231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM ~IND -

TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

======================================================r==============================='- .

42-10-PSSD VT-3 86E-03 03/13/95 95Ul-754P058 P Y N RIGID SUPPORT N/A ISI-PRI-I143 2.00 0.000 42-28-PRB VT-3 86E-03 03/13/95 95UI-754P057 P Y- N RIGID SUPPORT N/A ISI-PRI-I143 2.00 0.000 44-07-PRA VT-3 86E-03 03/14/95 95UI-754P067 P Y N-RIGID SUPPORT N/A ISI-PRI-I146 2.00 0.000 44-09-PRB VT-3 86E-03 03/14/95 95U1-754P061 P Y N RIGID SUPPORT N/A ISI-PRI-I146 2.00 0.000 44-28-PSSB VT-3 86E-03 03/14/95 95UI-754P060 P Y- N RIGID SUPPORT N/A ISI-PRI-I147 2.00 0.000 PAGE 8-2'

7 .

~

, .. _ .; e Wisconst] Electric Power Company Point Beach Nuclear Plant, Udt 1--

231 West Michigan Avenue .

6610 Nuclear Road Milwaukee, Wisconsin 53201 - - Two Rivers, Wisconsin 54241 .w Docket No. 50-266 <

Commercial Service Date 12/21/70 COMPDNENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND -

COMPONENT DESCIUPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS

- RELIEF MATERIAI. A & B

==========r=.t.========================================================================  :

45-05-PRA VT-3 86E-03 03/14/95 RIGID SUPPORT 95UI-754P071 P Y. -I N/A ISI-PRI-1148 2.00 0.000 r

45-07-PR VT-3 86E-03 03/14/95 95UI 754P070 Y RIGID SUPPORT P I N/A ISI-PRI-I148 - 2.00 0 noO 45-07-PSA VT-3 86E-03 03/14/95 95UI-754P075 Y RIGID SUPPORT P N N/A ISI-PRI-il48 2.00 0.000

46-01-PR VT-3 86E-03 03/13/95 RIGID SUPPORT 95UI-754P051 P Y N N/A ISI-PRI-l149 - 2.00 0.000 46-08-PR . VT-3 86E-03 03/13/95 95U1-754P050 P Y N RIGID SUPPORT N/A ISI-PRI-il49 2.00 0.000 1

PAGE 8-3.

_____ _ ____ _ _ __ _ _ _ ..___ _ __ _ _ _ _ _ . _ _ ~ . . _ _ . _ _ . . . _ -

.~

g  !

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 '~

Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. TIIICKNESS RELIEF MATERIAL A & B

=========================_ -_==============================================

6H-202 VT-3 86E-03 02/28/95 95UI-754P038 P Y-RIGID SUPPORT N

N/A ISI-PRI-1247 6.00 0.000 A-08 VT3 86E-03 03/14/95 95UI-754P065 P Y ANCHOR N N/A ISI-PRI-I138 3.00 0.000

- A-1I4 VT-3 86E 02/28/95 95U1-754P019 P Y ANCHOR N N/A ISI-PRI-1348 6.00 0.000 A-25/M82 VT-3 86E-03 03/13/95 95UI-754PO47 P Y ANCHOR N N/A ISI-PRI-1330 8.00 0.000 A/M-82 VT-3 86E-03 03/13/95 95UI-754P048 P Y ANCHOR N N/A ISI-PRI-1332 8.00 0.000 PAGE ' 8-4

_ _ _ - . - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - " - - - - - - ' ' - ~ ' ' ~ ' " *~ ^ ' ~ ~'~ ~ ~ ' '.a4

m.

.; c.;

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENTIDENTIFICATION METHOD EXAM EXAM EXAM DATA COMPONENT DESCRIMION RESULTS ' PROGRAM . IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS '

l ' RELIEF MATERIAL' A & B

======================================================================================.

. AC-08-RHR-1001-10 PT 86E-03 03/06/95

! ELBOW TO PIPE 95UI-451P001 P Y N UT 86E43 03/08/95 95UI-161P008 P Y C5.11B ISI-PRI-1225 8.00 0.322 G SS AC-10-AC-1001-12 M 86E-03 03/16/95

. PIPE TO ELBOW 95UI-451P025 P Y N UT 86E-03 03/17/95 95U1-161P002 P Y-B9.11 IS!-PRI-l122 10.00 1.000 .G-

~

SS AC-10-RHR-1002-14 M 86E-03 03/08/95 PIPE TO ELBOW 95UI-451P002 P Y N UT 86E-03 03/09/95 95U1-161P001 P Y G C5. IIB ISI-PRI-1222 10.00 0.365 SS RIGID SUPPORY COVERING WELD, ABLE TO OBTAIN CODE COVERAGE ON EXAMINATIONS.

CVC-02-AS-10CI-18 M 86E-03 ' 03/17/95 95UI-451P034 P Y N' COUPLING TO PIPE B9.40 ISI-PRI-I140 2.00- 0.344 SS ^

ASIESTOS REMOVAL IN PZR SURGE CUBE REQUIRED.

PAGE 8-5

m

. w g;x Wisconsin Electric Power Company Point Beach Nuclear Plant, UEit I ~  ;'

231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND '

COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS

! RELIEF MATERIAL A & B

=============================================================_========================-

CVC42-LD-1001-38 PT 86E-03 03/16/95 ~ 95U1-451P019 P' Y I ELBOW TO PIPE i B9.40 ISI-PRI-I147 - 2.00 0.344 -

SS CVC-02-PSI 1001-23 FT 86E43 03/14/95 95UI-451P005 P Y N PIPE TO ELBOW

, B9.C3 ISI-PRI-II43 2.00 0.344 SS CVC-02-PSI-1001-24 PT 86E 03/14/95 95UI-451P004 P Y ELBOW TO PIPE N

, B9.40 ISI.-PRI-l143 2.00 0.344 CVC-02-PSI-1002-03A PT - 86E-03 03/14/95 95UI-451P003 P Y TEE TO INSERT N

B9.40 ISI-PRI-I144 2.00 0.344 SS CVC-02-PSI-100201 FT 86E-03 03/16/95 95UI-451P023 P -Y N ELBOW TO PIPE B9.40 ISI-PRI-I144 ' 2.00 0.344 SS PAGE 8-6 l

w6

.m___.__m__ ________ _m__ .m m.m.___________m_.2____.._.m .m m, m- . . , _ < . - _ r e. - _,. ~ ~,.- ,m .. -,--,.-.-.m . .-.,.-e, _e - . ~ - - . - n,....m- e ., e,w.. . . mw i . .r. trey

. s Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-26e:

Commercial Service Date 12/21r'0 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA COMPONENT DESCRIFI~ ION RESULTS PROGRAM IND TYPE DATE SilEET CREDIT TYP ITEM ISOMETRIC DIA. TIIICKNESS RELIEF MATERIAL A & B

==========================================================================

CVC-02-PSI-1002-25 PT 86E-03 03/16/95 95UI-451P024 PIPE TO ELBOW P Y N B9.40 IFI-PRI-I144 2.00 0.344 SS CVC-03-CH-1001-12 PT 86E-03 03/14/95 95UI-451P006 ELBOW TO PIPE P Y N B9.21 ISI-PRI-1138 3.00 0.438 SS CVC-03-Cll-1001-14 PT 86E-03 03/14/95 95UI-451P007 ELBOW TO PIPE P Y N B9.21 ISI-PRI-ll38 3.00 0.438 SS EA-EB-2-3 VT-3 B03-03 03/01/95 95Ul-754P024 ENERGY ABSORBER P N I ENERGY ISI-PRI-1405 24.00 0.000 i:W-16-FW-1001-17 MT 86E-03 03/21/95 95UI-350P006 PIPE TO ELBOW P Y N UT 86E-03 03/21/95 95UI-161P007 P Y G C5.51 ISI-PRI-1245 16.00 0.843 CC PAGE 8-7

Wisconsin Electnc Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 -

Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENTIDENTIFICATION METHOD EXAM ' EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND  ;

TYPE DATE SHEET CREDIT -TYP' l ITEM ISOMETRIC DIA. THICKNESS i RELIEF MATERIAL A & B i

.................. =.....---..........========.............=....===...................-

FW-16-FW-1001-25 MT 86E-03 03/16/95 95UI-350P005 PIPE TO REDUCER P Y N UT 86E-03 03/20/95 95UI-161P005 P- Y G i

C5.51 ISI-PRI-1245 - 16.00 0.843 CC

' FW-16-FW-1001-26 MT 86E-03 03/16/95 95U1-350P0(M REDUCER TO NOZZLE EXTENSION P Y N UT 86E-03 03/20/95 95UI-161P004 P Y G C5.51 ISI-PRI-1245 16.00 0.843 . UT B07-03 03/20/95 95UI-161P004 P N G CC FW-16-FW-1002-17 MT 86E-03 03/16/95 95U1-350P003 REDUCER TO NOZZLE EXTENSION P Y N UT 86E-03 03/20/95 95UI-161P006 P Y G C5.51 ISI-PRI-1246 16.00 0.843 UT B07-03 03/20/95 95U1-161P006 P N -G CC FW-H05 VT-3 86E-03 03/13/95 4

RIGID SUPPORT 95U1-754POSS P Y N

, N/A ISI-PRI-1245 16.00 0.000 FW-H08 VT-3 86E-03 03/13/95 95UI-754P056 RIGID SUPPORT P Y N N/A ISI-PRI-1244 16.00 0.000 PAGE 8-8

- w v -

M -+ 4 +eg -+L f e- -e-+t~eT-a: m-'-- k--Pt+-w -x i4--+ + = -+e+ee7W- T esW++ +"e-Yh ee -e'+39+9-M--?++W-v~~-e--W-W N-e $r 3*W- F- 1."-

Wisconsis Electric Power Company Point Beach Nuclear Plant, Unit 1 -

231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241

"~

m.

Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

===========================-==========================================================-. _

H43A VT-3 86E-03 03/10/95 95UI-754PO42 RIGID SUPPORT P Y N N/A ISI-PRI-1347 24.00 0.000 H-ill VT-3 86E-03 02/28/95 94UI-754P020 P Y N RIGID SUPPORT N/A ISI-PRI-1348 6.00 0.000 H-17 VT-3 86E43 02/28/95 95UI-754P027 RIGID SUPPORT P Y R VT-3 R17-03 04/17/95 95UI-754P082 P N N N/A ISI-PRI-1323 6.00 0.000 H-200 VT-3 86E-03 03/14/95 95UI-754P064 RIGID SUPPORT P Y N N/A ISI-PRI-I136 3.00 0.000 H-206C VT-3 86E-03 03/28/95 95UI-754P077 RIGID SUPPORT P Y N

N/A ISI-PRI-1223 10.00 0.000 H-208 VT-3 86E-03 03/28/95 95UI-754P078 RIGID SUPPORT P Y N N/A ISI-PRI-1222 10.00 0.000 PAGE 8-9'

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET ITEM ISOMETRIC DIA.

CREDIT TYP.

TIIICKNESS RELIEF MATERIAL A & B

==========================================================================

H-25 VT-3 86E-03 02/28/95 95UI-754P015 RIGID SUPPORT P Y N N/A ISI-PRI-1322 8.00 0.000 11-2 8 VT-3 R15-03 01/06/95 95UI-754P008 P N N RIGID SUPPORT VT-3 SO4-03 02/28/95 95U1-754P014 N N/A P N ISI-PRI-1322 3.00 0.000 11-3 3 VT-3 86E-03 02/28/95 95UI-754P013 P Y N ANCIIOR N/A ISI-PRI-1334 4.00 0.000 II-33A VT-3 86E-03 03/10/95 95UI-754P039 P Y RIGID SUPPORT N N/A ISI-PRI-1324 24.00 0.000 H-37 VT-3 86E-03 02/28/95 95UI-754P012 RIGID SUPPORT P Y N N/A ISI-PRI-1324 6.00 0.000 11-3 8 VT-3 86E-03 02/28/95 95UI-754P025 P Y I RIGID SUPPORT N/A ISI-PRI-1324 8.00 0.000 PAGE 8-10

Wisconsin Electric Power Company ~ Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road s Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241-4 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIFFION PROGRAM IND TYPE DATE SHEET CREDIT TYP-ITEM ISOMETRIC DIA. THICKNESS

RELIEF MATERIAL A & B i

============================================================_-======================== _

l H-41 VT-3 86E-03 02/28/95 95UI-754P017 P Y.

RIGID SUPPORT N N/A ISI-PRI-1325 8.00 0.000

. H-55 VT-3 86E-03 02/28/95 95UI-754P016 Y RIGID SUPPORT P N N/A ISI-PRI-1333 6.00 0.000 H-77 VT-3 86E-03 03/02/95 '

RIGID SUPPORT 95U1-754P031 P Y N N/A ISI-PRI-1328 14.00 0.000 H-81 VT-3 86E-03 03/02/95 95UI-754P036 RIGID SUPPORT P Y N N/A ISI-PRI-1327 14.00 0.000 H-85 VT-3 86E-03 03/02/95 RIGID SUPPORT 95UI-754P035 P Y N N/A ISI-PRI-1326 14.00 0.000 t

' H-87 VT-3 86E-03 02/28/95 95UI-754P021 P Y RIGID SUPPORT N N/A ISI-PRI-1326 14.00 0.000 PAGE 8-11

. - . - - - - . , ~ . - _ . . . . - - . . . . - - ..- - --- ,-- . . , . _.- - . - . . . . . - , . . . . . . - , _ . . - . - - . - - x - . _ , _ _ _ = _ _ . - _ . _ _ _ .

Wisconsio Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wiscorisin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND TYPE DATE SHEET CREDIT TYP.

ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==================================================

1

' H-88 VT-3 86E-03 ~ 02/28/95 94UI-754P022 P Y N RIGID SUPPORT N/A ISI-PRI-1326 14.00 0.000 H-% VT-3 86E-03 02/28/95 95UI-754P023 P Y RIGID SUPPORT N N/A ISI-PRI-1328 8.00 0.000 HB VT-3 86E-03 03/10/95 95UI-754PO41 P Y I RIGID SUPPORT .

N/A ISI-PRI-1320 16.00 0.000

P Y I SNUBBER N/A ISI-PRI-1261 30.00 0.000 COMPONENT RENAMED AS A RESULT OF CR 93-430. OLD COMPNO HS-R8.

PAGE 8-12

_ . _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ - _. .. _ _ _. _ . . . ._ 1.

~ Wisconsin Electnc Power Company Point Beach Nuclear Plant; Unit 1

. 231 West Michigan Avenue - 6610 Nuclear Road =~

Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin $4241 -

Docket No. 50-266 ,

a Commercial Service Date 12/21/70

  • y-i ' COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND-TYPE DATE SHEET' CREDIT ..TYP .

ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B ,

======================================================================================-

HS-03 VT-3 86E-03 03/13/95 95UI-754PO49 P Y. 'N SNUBBER N/A ISI-PRI-1262 30.00 0.000 COMPONENT RENAMED AS A RESULT OF CR 93430. OLD COMPNO MS-RI.

I i

I MS-30-MS-1001-11 MT 86E-03 03/22/95 95UI-350P010 ElJOW TO PIPE P Y. N UT 86E-03 03/22/95 95UI-161P009 P Y I C5.51 ISI-l'RI-1240 30.tM 0.908 CC s

MS-30-MS-1001-IILD .MT 86E-03 03/22/95 95Ul-350P012 DOWNSTREAM LONG WELD P Y- N UT 86E-03 03/22/95 95U1-161P009 P. :Y N'

! C5.52 ISI-PRI-1240 30.00 0.908 1

RR-1-16 'CC 4

4 MS-30-MS-1001-1ILUO MT 86E-03 03/22/95 95UI-350P011 P-

OUTSIDil UPSTREAM LONG WELD -Y N UT 86E-03 03/22/95 95UI-161P009 P Y N i

C5.52 ISI-PRI-1240 30.00 0.908 RR-1-16 CC i MS-30-MS-1002-07 MT 86E-03 03/28/95 95UI-350P023 ELBOW TO PIPE P- Y N i UT 86E-03 03/28/95 95UI-161P012 P Y G C5.51 ISI-PRI-1262 30.00 0.908 CC t

b: h PAGE . 8-13 ,

I u__.._--..u.____.._.-,

. _ _ _ _ - - _ _ _ , , _ _a..__~.___ - , . _ _ . _ _ , . . _ _ . . _ _ _ _ _

. . . . - __ _ _ - . . . . - - _ _ . . _ . . . . _ _ _ ....--._-__.2._I'*_.

p

= t*; ,

Wisconsin Electnc Power Company _ Point Beach Nuclear Plant, Unit 1

. 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS

. COMPONENT DESCRIPTION PROGRAM IND TYPE DATE SHEET. CREDIT TYPc ITEM ISOMETRIC DIA. THICKNESS 4 RELIEF MATERIAL A & B 4

==========================================================================

MS-30-MS-1002-07LD MT 86E-03 03/28/95 95Ul-350P024 DOWNSTREAM LONG WELD P Y N UT 86E-03 03/28/95 95U1-161P016 P Y N

' C5.52 ISI-PRI-1262 30.00 0.908 RR-1-16 -CC

. MS-30-MS-1002-07LUO MT 86E-03 03/28/95 95U1-350P026 OUTSIDE UPSTREAM LONG WELD P Y N UT 86E-03 03/28/95 95UI-161P017 P Y' N C5.52 ISI-PRI-1262 30.00 0.908 RR-t-16 CC MS-30-MS-1002-08 MT 86E-03 03/28/95 95UI ~,50P019 PIPE TO ELBOW P' Y N UT 86E-03 03/28/95 95UI-161P011 P Y G C5.51 ISI-PRI-1262 30.00 0.908 CC

. MS-30-MS-1002-08LDO MT 86E-03 03/28/95 95UI-350P021 OUTSIDE DOWNSTREAM LONG WELD P Y N.

UT 86E-03 03/28/95 95UI-161P014 P Y N

, C5.52 ISI-PRI-1262 30.00 0.908

! RR-1-16 CC

' MS-30-MS-1002-08LU MT 86E-03 03/28/95 95UI-350P022 UPSTREAM LONG WELD P Y- N  :

UT 86E-03 03/28/95 - 95UI-161P013 P Y N C532 ISI-PRI-1262 30.00 0.908 RR-1-16 CC 1

PAGE 8-14

s ;, .s.-

- Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 1 231 West Michigan Avenue 6610 Nuclear Road -

Milwaukee, Wisconsin 53201. Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION ' METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT ..TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

====================================================================================== "

MS-30-MSR-1001-02-BC MT 86E-03 03/21/95 95UI-350P007 ' P Y N 8-IN BRANCH CONN C5.81 ISI-PRI-1242 8.00 0.000 CC MS-31-MS-1001-01 MT 86E-03 03/22/95 95UI-350P009 Y P N NOZZLE TO ELBOW UT 86E-03 03/23/95 95UI-161P010 P- Y' G C5.51 ISI-PRI-1261 31.00 1.500 CC MS-31-MS-1001-OlLDI MT 86E-03 03/22/95 95UI-350P014 P Y- N'

< INSIDE DOWNSTREAM LONG WELD .UT 86E-03 03/23/95 95UI-161P010 P Y G C5.52 ISI-PRI-1261 31.00 1.500 RR-1-16 CC

< MS-31-MS-1001-0lLDO MT 86E-03 03/22/95 95UI-350P013 P Y OUTSIDE DOWNSTREAM LONG WELD N '

UT 86E-03 03/23/95 95UI-161P010 . P Y G C5.52 ISI-PRI-1261 31.00 1.500

- RR-1-16 CC MS-65 VT-3 86E-03 . 03/27/95 95UI-754P076 'P~ Y- 'N

'- ANCHOR N/A ISI-PRI-1241 30.00 0.000 I

PAGE 8-15 1

. y Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 ._

231 West Michigan Avenue 6610 Nuclear Road ~-

Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 i

Commercial Service Date 12/21n0 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM - IND l COMPONENT DESCRINION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS l RELIEF MATERIAL A & B

==========================================================================

l PSR-003-3 VT-3 86E-03 02/28/95 95UI-754P0ll Y P I RIGID SUPPORT N/A ISI-PRI-1337 10.00 0.000 PSR-003-3A VT-3 86E-03 02/28/95 95UI-754P009 P Y N l RIGID SUPPORT N/A ISI-PRI-1338 10.00 0.000 PSR-005-3 VT-3 86E-03 04/03/95 95UI-754P080 Y RIGID SUPPORT P -N-N/A ISI-PRI-1337 10.00 0.000 PSR-013-3 VT-3 RIGID SUPPORT 86E-03 04/03/95 95UI-754P079 P Y N' N/A ISI-PRI-1336 10.00 0.000 PZR-CWELD-1-A UT 86E4)3 03/22/95 95UI-163P004 P Y N UPPER HEAD TO UPPER SHELL (0-120)

B2.II ISI-PRI-l105 96.00 5.000 CC PZR-CWELD-I-B UT 86E 03/22/95' 95UI-163P004 P Y '

N UPPER HEAD TO UPPER SHELL (120-240)

B2.II ISI-PRI-l105 0.00 0.000 CC PAGE 8-16

__ _ _.____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ . -- _ _ _ _ _ _ _ _~ -

Wisconsin Electric Power Cornpany Point Beach Nuclear Plant, Unit 1 '

231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Tvro Rivers, Wisconsin 54241 Docket No. 50-266 Conunercial Service Date 12/2in0 -

COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICLNESS RELIEF MATERIAL A & B 1

=================================================._========================

PZR-SKIRT-B VT-3 86E-03 03/22/95 95UI-754P072 P Y N COMPONENT SUPPORT N/A ISI-PRI-I105 0.00 0.000 1

1 R-205 VT-3 86E-03 03/13/95 95UI-754PO46 P Y N RIGID SUPPORT

. N/A ISI-PRI-1330 8.00 0.000

' R-92A VT-3 86E43 03/22/95 95UI-754P073 P Y N RIGID SUPPORT N/A ISI-PRI-l133 3.00 0.000 RC-02-BP-1001-03 PT 86E-03 03/16/95 95UI-451P0ll Y PIPE TO ELBOW P N B9.40 ISI-PRI-l136 2.00 0.344 SS RC-02-BP-1001-16 PT 86E-03 03/16/95 95UI-451P013 P Y N ELBOW TO PIPE B9.40 ISI-PRI-1136 2.00 0.344 SS PAGE 8-17

.-.. - . - . . - .. - - . . . ~. _ - . . - -

c  ;. .

. IVsconsin Electnc Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 .'

Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM- EXAM DATA RESULTS PROGRAM . IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT'. TYP-  !

. ITEM ISOMETRIC DIA. THICKNESS RELIEF . MATERIAL A & B

======================================================================================. +

RC-02-BP-1002-23 PT 86E-03 03/16/95 95UI-451P014 P Y PIPE TO ELBOW N

B9.40 ISI-PRI-I136 2.00 0.344 SS RC-02-BP-1003-01 PT 86E-03 03/17/95 95UI-451P030 P Y NL CROSS TO PIPE B9.40 . ISI-PRI-l137 2.00 0.344 SS t

RC-02-BP-1004-D PT 86E-03 03/17/95 95UI-451P029 P- Y- N' ELBOW TO PIPE B9.40 ISI-PRI-l137 2.00 0.344 SS RC-02-DR-1002-01 Fr 86E-03 03/16/95 95UI-451P026 P Y N BRANCH CONN TO PIPE

. B9.40 ISI-PRI-1148 2.00 0.344 -

SS '

[

RC-02-DR-100242 PT 86E-03 03/16/95 95UI-451P021 Y

! PIPE TO ELBOW P N.

t B9.40 ISI-PRI-l148 2.00 0.344 SS t

PAGE . 8-18 ~

Wisconsin Electric Power Company . Point Beach Nuclear Plant, Unit 1.

231 West Michigan Avenue 6610 Nuclear Road Milwauka, Wisconsin 53201 Two Rivers, Wisconsin 54241 -

Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION . METHOD EXAM' EXAM EXAM DATA RESULTS -

COMPONENT DESCRIMION PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC . DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

RC-02-DR-1002-02B FT 86E-03 03/16/95 PIPE TO ELBOW 95UI-451P020 P Y N

- B9.40 ISI-PRI-I148 2.00 0.344 SS

' RC-02-DR-1002 08 PT 36E-03 03/16/95 95U1-451POIS P 'Y N PIPE TO ELBOW B9.C ISI-PRI-l148 2.00 0.344 SS RC-02-DR-1002 FT 86E-03 03/16/95 95UI-451P016 PIPE TO ELBOW P Y N-l B9.40 ISI-PRI-l148 2.00 0.344 SS RC-02-DR-1002-1IB PT 86E-03 03/16/95 95U1-451P017 COUPLING TO PIPE P Y N B9.40 ISI-PRI-1148 2.00 0.344 SS RC-02-LD-1001-06A PT 86E-03 03/17/95 TEE TO INSERT 95U1-451P036 P Y N B9.40 ISI-PRI-l146 2.00 0.344 SS PAGE 8-19

_ _ _ . _.- ________________..m____ ____m____-.2__.._.___.___m.___._____._-___m__.__ . _ _ _ _ m __ ___._____.;*_____ . . - - _ , . * ---

A A L *

  • t

-4 's rL -4*_

- " - A A L

,a g4

- Wisconsm Electne Power Company Point Beach Nuclear Plant Unit 1 231 West Michigan Avenue - 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266

  • Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA '

- COMPONENT DESCRIPTION RESULTS- PROGRAM IND '

TYPE DATE SHEET CREDIT -

ITEM ISOMETRIC DIA. THICKNESS TYP -

RELIEF MATERIAL A & B i

======================================================================================J I RC-03-BP-1001-08 IT 86E-03 03/16/95

PIPE TO ELBOW 95U1-451P012 ' P Y N

B9.21 ISI-PRI-1136 3.00 0.438 SS '

i 1

' RC-03-PS-1002-10 N 86E-03 ' 03/17/95 95U1451P035 P Y- N ELBOW TO PIPE +

. B9.21 ISI-PRI-I134 3.00 0.438

, SS

' RC-03-PS-1002-12 PT 86E-03 03/17/95 95UI-451P033 -

ELBOW TO PIPE P Y N

' B9.21 ISI-PRI-ll34 3.00 0.438 i- SS

RC-06-SI-1003-01 IT 86E-03 03/16/?3 95Ul-451P018

- BRANCH CONN TO PIPE P Y N UT 86E-03 03/17/95 95UI-161P003 -P Y G

, B9.11 ISI-PRI-I120 6.00 0.562 i SS

' RC-34-MRCI<AI4)3 PT 86E-03 '03/15/95 95U1-451P008 t ELBOW TO A S/G INLET NOZZLE P Y N-UT 86E-03 03/16/95 - 95UI-167P002 - P N G' B5.13Q ISI-PRI-I120 - 34.00 3.000 SS 4

i '

PAGE 20 l

i

,______2._..._ ~.2,.'._

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM COMPONENT DESCRIPTION EXAM DATA RESULTS PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. TIIICKNESS RELIEF MATERIAL A & B -

=====================================================================================.

RC-34-MRCI BI-02 FT 86E-03 03/17/95 PIPE TO ELBOW 95UI-451P031 P Y N UT 86E-03 03/17/95 95UI-167P004 P N B9.II ISI-PRI-I121 34.00 3.000 G SS ALIGNMENT PUNCH MARKS IN BASE METAL ADJACENT TO WELD. Code limited exam because of geometrical configurat on i of pipe and cibow. Obtained coverage of 78% from cibow side and 69% from pipe side. Cannot get two beam coverage from one side because of cast stdaless steel characteristics.

RC-34-M.tCl BI-03 PT 86E-03 03/17/95 95UI-451P032 P Y N ELBOW TO B S/G INLET NOZZLE UT 86E-03 03/17/95 95UI-167P003 B5.130 P N G ISI-PRI.I121 34.00 3.000 SS Code limited examination because of nozzle and pipe configuration. Able to obtain 28% coverage from nozzle side and 33.5% from the(Ibow side. Unable to obtain two beam coverage from one side because of cast stainless steel characteristics.

ALIGNMENT PUNCH MARKS IN BASE METAL, ADJACENT TO WELD.

RC-36-MRCI-AII-03 PT 86E-03 03/15/95 95UI-451P010 PIPE TO ELBOW P Y N UT 86E-03 03/16/95 95U1-167P001 P N B9.ll ISI-PRI-il20 36.00 3.000 G SS Limited examination due to configuration of piping and elbow. Coverage obtained was 100% from the pipe side and 86.2% from the elbow side. Unable to get two beam coverage from one side because of cast stainless steel.

RC-36-MRCI AII-DR-BC PT 86E-03 03/15/95 95U1-45IP009 2-IN BRANCH CONN P Y N-B9.32 ISI-PRI-1120 36.00 3.000 SS PAGE 8-21

, ,yv

-Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit I

- 231 West Michigan Avenue 6610 Nuclear Road -

Milwaukee, Wisconsin $3201' Two Rivers, Wisconsin 54241 -

Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

--==================================================================. =.=====.-==...==

RCP-B-FLYWHEEL UT B02-03 03/30/95 95UI-150P001 PUMP FLYWHEEL P N N VT-1 B02-03 03/30/95 95U1-750P005 P N N FLYWHL ISI-PRI-1404 0.00 0.000 UT B02-03 03/30/95 95UI-150P002 P N N RCP-B-FLYWHEEL-BORE PT B02-03 03/30/95 94UI-450P002 PUMP FLYWHEEL P N N VT-1 B02-03 03/30/95 95U1-750P007 P N N BORE ISI-PRI-1404 0.00 0.000 RCP-B-FLYWHEEL-KEYWAY VT-1 B02-03 03/30/95 95U1-750P006 P- 'N PUMP FLYWHEEL N PT B02-03 03/30/95 95U1-450P001 P N N KEYWAY ISI-PRI-1404 0.00 0.000 RCP-B-SLBLT-01 THRU 18 VT-1 86E-03 03/22/95 95U1-750P002 P N RCP #1 SEAL BOLTING N MT B04-03 03/22/95 95UI-353P003 P N N-B7.60 ISI-PRI-I110 0.00 0.000 RCP-LR-02 MT B01-03 03/13/95 95UI-350P001 P N N LIFT RIG SPREADER ASSY WELD RCPMTR ISI-PRI-1403 0.00 0.000 RHR-B UT 86E-03 03/07/95 95UI-166P002 P Y G l SHELL TO HEAD l

C1.20 ISI-PRI-1204 0.00 0.000 CC l PAGE 8-22 .

l L______.___-_________.____-. - --. - - - - - - . - - - -- - -- - - - - - + - - - - -- -- ~ --' ~~ ~~ ~ '~~ * -

J, .  :. . ;

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Conunercial Service Date 12/21/70 COMPONENTIDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

=
======================================a=====================

RHR-B-2 UT 86E-03 03/07/95 95U1-166PL91 P SHELL TO FLANGE Y' G C1.10 ISI-PRI-1204 0.00 0.000 CC RPV-HFLANGE-B MT 86E-03 03/24/95 95U1-350P015 P Y .I HEAD TO FLANGE (AZ. 120-240) UT 86E-03 03/24/95 95UI-163P005 P Y- N' B1.40 ISI-PRI-l102 157.25 5.750 CC RPV-HLR-02 MT B01-03 03/24/95 95UI-350P016 P N N CLEVIS PLATE TO LEG WELD RPVHEA ISI-PRI-1401 0.00 0.000 RPV-HLR-05 MT B01-03 03/24/95 95UI-350P017 P N N RING GIRD-SUPPORT LUG WELD RPVHEA ISI-PRI-1401 - 0.00 0.000 RPV-HLR-08 MT B01-03 03/16/95 95UI-350P002 P N SIDE LUG-SLING ASSY LINK WELD N

RPVHEA ISI-PRI-1401 0.00 0.000 RPV-INTERIOR VT-3 86E-03 03/18/95 95UI-755P001 P Y ~N VESSEL INTERIOR SURFACES B13.10 ISI-PRI-1101 132.00 0.000 PAGE 8-23

=

{g,  ;$

  • Wisconsin Electric Power Company [ Point Beach Nuclear Plant, Unit 1 -

231 West Michigan Avenue i. . . 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 5424I

, g Docket No. 50-266 Commercial Service Date 1 1/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM . IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT ~TYP ITEM ISOMETRIC DIA. THICKNESS

. RELIEF MATERIAL A & B

======================================================================================-

RPV-NUT-17 MT 86E-03 03/28/95 95U1-350P051 P N; CLOSURE NUT Y.

B6.10 ISI-PRI-I103 8.50 7.875 i RPV-NUT-18 MT 86E-03 ' 03/29/95' 95UI-350P052 P Y N CLOSURE NUT B6.10 ISI-PRI-l103 8.50 7.875 RPV-NUT-19 MT 86E-03 03/29/95 95UI-350P055 P Y 'N CLOSURE NUT ,

B6.10 ISI-PRI-Il03 8.50 7.875 RPV-NUT-20 MT- 86E-03 03/30/95 95UI-350P057 P Y I CLOSURE NUT s B6.10 ISI-PRI-I103 8.50 7.875 RPV-NUT-21 MT 86E-03 03/28/95 95UI-350P050 P Y N CLOSURE NUT '

B6.10 ISI-PRI-I103 8.50 7.875 RPV-NUT-22 MT 86E-03 03/29/95 95UI-350P054 P Y N CLOSURE NUT B6.10 ISI-PRI-I103 8.50- 7.875 PAGE 8-24 .

=

__ -_._m____-.___.m__m___ a- - . _ . - - . _ ....,.-_____u-..-emu.__ __m - - _ - _ _ . _ _ _ _ _ _ _ _ -_m- ei -. -,_s,--em umaw g---usrw-**--M-w- nas-f.ph.-r' rMw*is-T m WW+w'Tm' Ya+--> m.ad <ae v y w M+ s-wY *w+-f vyer~ w w

. . g:

Wisconsin Electric Power Company - Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==

=====================================================================

RPV-NUT-23 MT 86E-03 03/29/95 95UI-350P053 CLOSURE NUT P Y N B6.10 ISI-PRI-I103 8.50 7.875 s

RPV-NUT-24 MT 86E-03 03/30/95 95UI-350P056 CLOSURE NUT P Y N B6.10 ISI-PRI-l103 8.50 7.875 RPV-NUT-25 MT 86E-03 03/27/95 95UI-350PO44 P Y CLOSURE NUT N B6.10 ISI-PRI-1103 8.50 7.875 RPV-NUT-26 MT 86E-03 03/27/95 95UI-350PO47 CLOSURE NUT P Y N

' VT-1 X01-03 03/27/95 95U1-750P013 P N I B6.10 ISI-PRI-I103 8.50 7.875 RPV-NUT-27 MT 86E-03 03/27/95 95UI-350P046 CLOSURE NUT P Y N B6.10 ISI-PRI-I103 8.50 7.875 RPV-NUT-28 MT 86E-03 03/28/95 95UI-350PO48 P Y .N CLOSURE NUT B6.10 ISI-PRI-Il03 8.50 7.875 PAGE 8-25

Wisconsin Electric Power Company - Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METilOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIIrrION PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

RPV-NUT-29 MT 86E-03 03/27/95 95UI-350PO45 CLOSURE NUT P Y N B6.10 ISI-PRI-1103 8.50 7.875 RPV-NUT-30 MT 86E-03 03/27/95 95UI-350PO42 CLOSURE NUT P Y N B6.10 ISI-PRI-l103 8.50 7.875 RPV-NUT-31 MT 86E-03 03/27/95 95UI-350PO43 CLOSURE NUT P Y N B6.10 ISI-PRI-I103 8.50 7.875 RPV-NUT-32 MT 86E-03 03/28/95 95UI-350PG49 CLOSURE NUT P Y N B6.10 ISI-PRI-1103 8.50 7.875 RPV-STUD-17 MT 86E-03 03/28/95 95UI-350P036 P Y N CLOSURE STUD UT 86E-03 03/18/95 95U1-160P001 B6.30 ISI-PRI-I103 P Y N 6.00 56.625 C

RPV-STUD-18 MT 86E-03 03/29/95 95UI-350P037 CLOSURE STUD P Y N UT 86E-03 03/20/95 95U1-160P002 P Y N B6.30 ISI-PRI-l103 6.00 56.625 C

PAGE 8-26

.,; p Wisconsin Electnc Pbwer Company 1 Point Beach Nuclear Plant, Unit 1

__ 231 West Michigan Avenue -- 6610 Nuclear Road -

Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241. '

Docket No. 50-266 c' Commercial Service Date 12/21/70 '

COMPONENT IDENTIFICATION METHOD EXAM EXAM COMPONENT DESCRIPTION EXAM DATA RESULTS PROGRAM ' IND 4

. TYPE -DATE SHEET ITEM CREDIT - TYP' ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B -

i

======================================================================================:

. RPV-STUD-19 MT 86E-03 03/29/95 95UI-350P039 P Y N CLOSURE STUD UT 86E-03 03/20/95-B6.30 ISI-PRI-I103 6.00 56.625 95U1-160P003 P Y- N C i RPV-STUD-20 MT' 86E-03 03/30/95' CLOSURE STUD -UT 95UI-350P058 P. Y N 86E-03 03/20/95 95U1-160P004 P- Y N B6.30 ISI-PRI-1103 6.00 56.625 C

l RPV-STUD-21 MT 86E-03 03/28/95 95UI-350P035 P- Y N

-CLOSURE STUD UT 86E-03 03/20/95 B6.30 95UI-160P005 P Y N-ISI-PRI-I103 6.00 56.625 1 C

RPV-STUD-22 MT 86E-03 03/29/95 CLOSURE STUD 95UI-350P038 P Y -N UT 86E-03 03/20/95 95UI-160P006 P Y N B6.30 ISI-PRI-Il03 6.00 56.625 C

, RPV-STUD-23 MT 86E-03 03/29/95 95UI-350PO40 P~ Y CLOSURE STUD - UT I 86E-03 03/20/95 95U1-160P007 B6.30 ISI-PRI-l103. 6.00 ' 56.625 P Y- -N

'PAGE 8-27 .

Wisconsin Electnc Power Company . Point neach Nuclear Plant, U.dt 1 -

231 West Michigan Avenue . . 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 -

Docket No. 50-266 Commercial Service Date 12/21/70

' COMPONENT IDENTIFICATION METHOD EXAM ' EXAM EXAM DATA -

COMPONENT DESCRIPTION RESULTS PROGRAM IND. - .l TYPE DATE SHEET CREDIT - TYP' '!

, ITEM ISOMETRIC DIA. THICKNESS RELIEF ~ MATERIAL A & B

======================================================================================-

RPV-STUD-24 MT 86E-03 03/30/95 95UI-350PO41 P' CLOSURE STUD Y I UT 86E-03 03/21/95 95U1-160P008 P Y I B6.30 ISI-PRI-1103 6.00 56.625 C

1 RPV-STUD-25 MT 86E-03 03/27/95 95UI-350P029 CLOSURE STUD P Y LN UT 86E-03 03/21/95 95UI-160P009 P Y 1 B6.30 ISI-PRI-I103 6.00 56.625 C

RPV-STUD-26 MT 86E-03 03/27/95 95UI-350P032 CLOSURE STUD '

P Y N UT 86E-03 03/21/95 95U1-160P010 P Y N B6.30 ISI-PRI-l103 6.00 56.625 C -

RPV-STUD-27 MT. 86E-03 03/27/95 95UI-350P031 CLOSURE STUD P Y N UT 86E4)3 - 03/21/95 95U1-160P011 P Y N B6.30 ISI-PRI-I103 6.00 56.625 C ,

RPV-STUD-28 MT 86E-03 03/28/95 95UI-350P033 CLOSURE STUD P Y N f UT 86E-03 ' 03/21/95 95U1-160P012 P Y N i B6.30 ISI-PRI-I103 6.00 56.625 C

PAGE 8-28 i

--.-.,I__

~

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit i 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commetual Service Date 12/21/70

' COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIIrrION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

. RPV-STUD-29 MT 86E-03 03/27/95 95UI-350P030 P Y N CLOSURE STUD UT 86E-03 03/21/95 95U1-160P013 Y B6.30 ISI-PRI-1103 6.00 56.625 P N' C

RPV-STUD-30 MT 86E-03 03/27/95 95UI-350P027 P CLOSURE STUD Y' N UT 86E-03 03/21/95 95UI-160P014 P Y N B6.30 ISI-PRI-1103 6.00 56.625 C

RPV-STUD-31 MT 86E-03 03/27/95 95UI-350P028 CLOSURE STUD P Y N~

UT 86E-03 03/21/95 95U1-160P015 P Y N B6.30 ISI-PRI-I103 6.00 56.625 C

RPV-STUD-32 MT 86E-03 03/28/95 95UI-350P034 P Y CLOSURE STUD N UT 86E-03 03/21/95 95U1-160P016 P Y I B6.30 ISI-PRI-I103 6.00 56.625 C

RPV-WASH VT-1 86E-03 03/28/95 95UI-750P033 CLOSURE WASHER P Y N B6,50 ISI-PRI-l103 9.00 3.000 C

PAGE 8-29

a--

Wisconsin Electric Power Company - Point Beach Nuclear Plant, Unit i 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 - Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENTIDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS ' PROGRAM IND:

COMPONENT DESCRIFilON TYPE iDATE SHEET CREDIT ITEM TYP-ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

RPV-WASH-18 VT-1 86E-03 03/29/95 95UI-750P034 P Y N CLOSURE WASHER B6.50 ISI-PRI-I103 0.00 3.000 C

RPV-WASH-19 VT-1 86E-03 03/29/95 95UI-750P037 Y CLOSURE WASHER P N-B6.50 ISI-PRI-I103 9.00 3.000 C

RPV-WASH-20 VT-1 86E-03 03/30/95 95Ul-750P039 P Y N CLOSURE WASHER

' B6.50 ISI-PRI-1103 9.00 3.000 C

+

RPV-WASH-21 VT-1 86E-03 03/28/95 95UI-750P032 CLOSURE WASHER P Y .N I B6.50 ISI-PRI-I103 9.00 3.000 C

RPV-WASH-22 VT-1 86E-03 03/29/95 95UI-750P036 P Y

' CLOSURE WASHER N

B6.50 ISI-PRI-1193 9.00 ~ 3.000 C

PAGE 8-30 "h

Wisconsin Electric Power Company Point Beach Nuclear Plant, IXit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CPti.olT ITEM ISOMETRIC TYP DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

RPV-WASH-23 VT-1 86E-03 03/29/95 95UI-750P035 CLOSURE WASHER P Y N B6.50 ISI-PRI-l103 9.00 3.000 C

RPV-WASH-24 VT-1 86E-03 03/30/95 95UI-750P038 CLOSURE WASHER P Y N B6.50 ISI-PRI-l103 9.00 3.000 C

RPV-WASH-25 VT-1 86E-03 03/27/95 95UI-750P026 P Y CLOSURE WASHER N B6.50 ISI-PRI-1103 9.00 3.000 C

RPV-WASH-26 VT-1 86E-03 03/27/95 95UI-750P029 P Y CLOSURE WASHER N B6.50 ISI-PRI-I103 9.00 3.000 C

RPV-WASH-27 VT-1 86E-03 03/27/95 95UI-750P028 P CLOSURE WASHER

.Y N B6.50 ISI-PRI-l103 9.00 3.000 C

PAGE 8-31

.,l Wisconsin Electric Power Company Poiat Beach Nuclear Plant. Unit 1 231 West Michigan Aventa 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two R.ivers, Wisconsin $4241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS COMPONENT DESCRIPTION PROGRAM IND TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

, RPV-WASH-28 VT-1 86E-03 03/28/95 95U1-750P030 CLOSURE WASHER P Y :N'

, B6.50 ISI-PRI-I103 9.00 3.000 C

RPV-WASH-29 VT-1 86E-03 03/27/95 95UI-750P027 CLOSURE WASHER P Y N B6.50 ISI-PRI-I103 9.00 3.000 C

RPV-WASH-30 VT-1 86E-03 03/27/95 95UI-750P024 CLOSURE WASHER P Y N B6.50 ISI-PRI-l103 9.00 3.000 C

RPV-WASH-3I VT-1 86E4)3 03/27/95 95U1-750P025 CLOSURE WASHER P -Y N B6.50 ISI-PRI-I103 9.00 3.000 C

RPV-WASH-32 VT-1 86E-03 03/28/95 95UI-750P031 CLOSURE WASHER P Y N B6.50 ISI-PRI-I103 9.00 3.000 C

-PAGE 8-32

-_ _ .- .-~. _ ._._. . . _ _ . _ - . __ . _. . _ _ _ - _ _ _ - - - _ _ . . . _ . _ . . - . _ _ _ . . _ . . _ - _ _ _ - . . _ . _ . _ . _ - - , . . _ _ . . . . _ _ _. . _ _ 2

- _ _ _ _ - _ _ ~ _ _ _

Wisconsin Electric Power Company

- 231 West Michigan Avenue Milwaukee, Wisconsin 53201 -

Point Beach Nuclear Plant, Unit 1 6610 Nuclear Road '

[

Two Rivers, Wisconsin 54241

  • lj Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA COMPONENT DESCRIPTION RESULTS PROGRAM IND.

TYPE DATE SHEET CREDIT. TYP ITEM ISOMETRIC DIA. THICKNESS

- RELIEF MATERIAL A & B 'j

====================================================_================================= _

UT 86E-03 03/16/95 95UI-163P001 P Y B HEET TO STUB BARREL G Cl.30 ISI-PRI-1201 0.00 0.000 CC SG-A-2 :UT 86E-03 03/16/95 95UI-163P002 P -Y N

SHELL TO STUB BARREL CIRCUM WELD C1.10 ISI-PRI-1201 0.00 0.000 CC UT 86E43 03/16/95 95UI-163P003 P Y LO ER H D TO TUBE SHEET (120-240) .O B2.40 ISI-PRI-l106 0.00 0.000 CC SG-B-MWAY-INLET-BLT-01 THRU 16 VT-1 86E-03 03/25/95 9501-750P003 'P MANWAY BOLTING Y N B7.30 ISI-PRI-1202 0.00 0.000 SG-B-MWAY-OUTLET-BLT-01 THRU 16 VT-1 86E-03 03/25/95 95UI-750P004 P MANWAY BOLTING Y- N B7.30 ISI-PRI-1202 0.00 0.000 PAGE 8-33

Wisconsin Electric Power Company Point Beach Nuclear Plant, Udt 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SilEET CREDIT TYP ITEM ISOMETRIC DIA. TillCKNESS RELIEF MATERIAL A & B

=================================== =,....................... ,,,,,,,,,,,,,,,,,,,,,

SI-15 VT-3 86E-03 02/28/95 94UI-754P018 Y P N RIGID SUPPORT N/A ISI PRI-1255 4.00 0.000 51-18 VT-3 86E-03 03/01/95 95UI-754P029 P Y N RIGID SUPPORT N/A ISI-PRI-1254 4.00 0.000 SI-30 VI.3 86E4)3 03/13/95 95UI-754P054 Y ANCHOR P- N N/A ISI-PRI-1253 4.00 0.000 SI-32 VT-3 86E-03 03/13/95 RIGID SUPPORT 95UI-754P053 P Y- N' N/A ISI-PRI-1253 4.00 0.000 SI-33 VT-3 86E-03 03/13/95 95UI-754P052 P Y RIGID SUPPORT N N/A ISI-PRI-1253 4.00 0.000 SI-43 VT-3 86E-03 03/01/95' 95U1-754P028 P Y- N ~

RIGID SUPPORT N/A ISI-PRI-1254 4.00 0.000 PAGE 8-34

._ , . _ _ _ _ _ . - _ - _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ A

w ..-

~

Wisconsin Electne Power Company Point Beach Nuclear Plant, Unit 1 -

231 West Michigan Avenue 6610 Nuclear Road -

Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM 'IND :

1 COMPONENT DESCRIPTION . TYPE DATE SHEET ITEM CREDIT .TYP -;

' ISOMETRIC DIA. THICKNESS "

RELIEF MATERIAL A & B

==========================--===========================================================L

+

SI-51 VT-3 86E-03 02/28/95 95UI-754P026 -P RIGID SUPPORT Y I-N/A ISI-PRI-1252 4.00 0.000 51-54 VT-3 86E-03 03/01/95 95UI-754P032

~ P Y I RIGID SUPPORT N/A ISI-PRI-1252 4.00 0.000

$1-55 VT-3 P19-03 12/12/94 95U1-754P002 P N 'N.

RIGID SUPPORT VT-3 86E-03 03/01/95 95UI-754P030 P Y I N/A ISI-PRI-1252 4.00 0.000 VT-3 R16-03 04/17/95 95UI-754P083 P N N ,

t 3

51-63 VT-3 86E4)3 03/14/95 95UI-754P063 P Y N RIGID SUPPORT N/A ISI-PRI-1252 4.00 0.000 1

SI-75 VT-3 ' 86E-03 02/28/95 95UI-754P010 Y RIGID SUPPORT P N N/A ISI-PRI-1258 ' -2.00 0.000 SI-84 ' VT-3 86E-03 03/10/95 95Ul-754PO43 P Y I RIGID SUPPORT N/A ISI-PRI-1259 2.00 0.000 PAGE 8 _ _ _ _ . . _ _ _ _ _ . . _ _ _ _._________ _ _. _ _ _ . _ .. _ ___ __ _ _____ _ _ _ , . . _ _ . . _ _ _ . _ . . . _ . . . _ . . . _ _ . _ _ _ . _ _ . _ _ _ . _ . - . _

%'> -h 'm Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 1 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-266 Commercial Service Date 12/21/70 COMPONENT IDENTIFICATION METIIOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

SIS-02-SI-1002-07 Irr 86E-03 03/16/95 95UI-451P027 P Y N PIPE TO ELBOW B9.40 ISI-PRI-I149 2.00 0.344 SIS-02-SI-1002-08 PT 86E-03 03/16/95 95Ul-451P028 P Y .. N-ELBOW TO PIPE B9.40 ISI-PRI-1149 2.00 0.344 SS PAGE 8 - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ . . _ . - _ _ _ _ . _ _ _ _ . _ . . . - _ _ _ _ . _ _ .__ _ . . _ , .__ _. _ _ . . _ . . . . _ . - _

W- o P e, c 231 West Michigan Aveeme -

Milwaukee.WI 53201 Point Beach Nuclear Plant. Unit 1 .,

6610 Nuclear Road Two Rivers. WI 54241 Docket 50-266 -

ConunercialService Date 12/21/70 2.5 Pressure Tests 2.5.1 ASME Section XI Pressure Tests Following are pressure tests that have been conducted as pa't of the pressure test program at PBNP since the last refueling outage.

'i s

i Page 9 of 20

p. y . l Wi.co m s.cate w c2 L 231 Wes Michigan Avenue - .

.* MHwaukee,WI $3201 -  !

Point Beach Nuclear Plant. Unit I 6610 Nuclear Road ,

Two Rivers, WI $4241 >

Docket 50-266 _l CommercialService Daw 12/21/70 )

I i

Pressure Tests-i i

1 i

I i

1 1

Page 10 of 20 j i

I

J.

Wisconsin Electnc Power C1 231 West Michigan Avenue

. Milwaukee, WI $3201 Point Beach Nuclear Plant, Unit 1 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-266 CommercialService Date 12/21f70 TEST DESCRIFTION: 40 Month Inservice Pressure Test of Service Water System inside Containment (Unit 1).

SYSTEM: Service Water TEST DOCUMENTS: IT-1080, Part 1 COMPLETION DATE: March 11,1995 TEST DESCRIPTION: 40 Month Inservice Pressure Test of Component Cooling Water Piping and Components Inside Containment (Unit 1).

SYSTEM: Component Cooling Water TEST DOCUMENTS: IT-1020, Part 1 COMPLETION DATE: March 11,1995 TEST DESCRIPTION: System Leakage Test of Class 1 Components Following Refueling Outage (Unit 1).

SYSTEM: Reactor Coolant TEST DOCUMENTS: IT-230 COMPLETION DATE: April 14,1995 4

P l

1 l

Page 11 of 20

m ..

Wisconsan Elecenc Power 01 231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit I 6610 Nuclear Road Two Rivers, WI $4241 Docket 50-266 Conunercialservice Date 12/21no 2.6 Snubber Surveijlance Tests 2.6.1 ASME Section XI Snubber Surveillance Tests Following are snubber inservice tests that have been conducted for snubbers less than 50 kips as part of the snubber surveillance test program at PBNP since the last refueling outage.

Page 12 of 20

,+ ,a ., _= -

/

.i Wisconsan Elecoic Power Co.~ ,

. 231 Wes Mactugan Avenue ei Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit i 6610 Nuclear Road .

Two Rivers, WI $4241 Docket 50-266 Commercialhervice Date 12/2100 1

Snubber Surveillance Tests ,

l l

l

'l.

I 1

l 1

I Page 13 of 20 i

,t' ,8 W cousin Bectnc Power Ce.

231 Ylest Michigan Avenue

i. Milwaukee, WI $3201 -

Point Beach Nuclear Plant, Unit !

6610 Nuclear Road Two Rivers, WI 54241 '

Docket 50-266 CommercialService Date 12/2100 TEST DESCRIPTION: Snubber Inservice Test for Snubbers Less than 50 kips (Unit 1)

SNUBBER HS-2501R-43 TEST DOCUMENTS: MWR. 9411991 COMPLETION DATE: April 4,1995 i

I l

l l

l l

l J

l i

Page 14 of 20

_. . . . -. __.m .. _ . _ ,_ - _ ._ , .- m. .. . .m ._

3; ,

Wiscwin Electric Power Co.

" Mduaukee.WI 53201 Pouw Beach Nuclear Plant. Una 1 6610 Nuclear Road g Two Rivers. WI 54241 Docket 50-266 Commercialservice Daar 12/2100 l 3.0 MSTRACT OF CONDITIONS NOTED AND CORRECTIVE MEASURES TAKEN '

t 3.1' Comoonent/ Weld Nondestructive examinations were performed by QTS, Raytheon-EBASCO, and PWA  !

personnel. The nondestructive examinations utilized VT, PT, MT, RT, and UT techniques. All the examinations were performed in accordance with written l

procedures that conform to the applicable sections of the ASME Boiler and Pressure Vessel Code. The following is a summary of the recordable indications found during i the examinations and evaluated by PBNP personnel.

95UI-7P001, Class 3 Rigid Support, PSR-003-3 I Datasheet 95U1-754P011, Drawing No. ISI-PRI-1337 Indication: Foreign object (screw) lodged between pipe and support ,

Disposition:. Work order to remove screw This support was previously examined in the second 10 year interval with no reportable indications. The foreign object probably came from maintenance work in

-i the overhead area. No damage to the support or pipe was caused by the presence of .

the screw. A work order was. written to remove the screw. j 95UI-7P002, Class 2 Rigid Support, SI-54 -

Datasheet 95U1-754P032, Drawing No. ISI-PRI-1252 Indication: Incomplete thread engagement on clevis bolt  :

Disposition: Accept as is -

This condition does not violate the acceptance criteria ofIWF-3410. Evaluation revealed that this support was previously inspected in response to CR 91-094 with no indications recorded. This type of discrepancy was not required to be recorded ]

during the previous inspection. The nut is tight with no evidence of loosening. This - '

meets the design requirements for this type of nut / bolt application. The component is j operable, no additional or successive examinations are required.

95U1-7P003, Class 3 Rigid Support, HE Datasheet 95U1-754P040, Drawing ISI-PRI-1321 Indication: Blistered paint and general corrosion Disposition: Accept as is, work order submitted for painting and preservation The condition does not violate the acceptance criteria of IWF-3410. This support was previously examined during U1R13 with no recordable indications. This indication probably did not exist at that time. ' The indication was evaluated as non-relevant in accordance with IWF-3410(b)(5). No additional or successive Page 15 of 20  ;

.y . . .. ., _

n. , 4 .-

.a wim:o sieanc power ca.

231 won Mactugan Avenne i Milwaukee.wl 5320I Point Beach Nucinar Plant. Unit 1 6610 Nuclear Road Two Rivers. WI 54241 -

oockerso.266 -

Conunercialservice Date 12/21/70 y

examinations are required. A work order was submitted to include the support into :

the Service Water painting and preservation program. j 95UI-7P004, Class 3 piping support, HB '

Datasheet 95U1-754P041, Drawing ISI-PRI-1320 g - Indication: Blistered paint and general corrosion, cracked grout on corner of base

' pad.  :

Disposition: Accept as is The condition does not violate the acceptance criteria of IWF-3410. This support was previously examined during UIR13 with no recordable indications. This .

indication probably did not exist at that time. The general corrosion / blistered paint indication was evaluated as non-relevant in accordance with IWF-3410(b)(5).~ The crack in grout at the corner of the base pad does not affect the load bearing capability of the base pad. The nature of the crack is such that it had to occur from an external ,

source and is not inservice related. No additional or successive examinations are. ,

required. . A work order was submitted to include the support into the Service Water '

painting and preservation program. ,

95UI-7P005, Non-Class Energy Absorber, EA-EB-2-3  !

Datasheet 95U1-754P024, Drawing ISI-PRI-1405 '  !

Indication: Incomplete thread engagement on clevis bolt Disposition: Accept as is -l 1

The energy absorber is not an ASME Section XI required examination. - It is an - .

augmented examination. The nut is tight with no evidence of loosening. This meets the design requirements for this type of nut / bolt application. - No additional actions -  :

are required. l 95Ul-7P006, Class 3 Rigid Support, H-38 Datasheet 95U1-754P025, Drawing ISI-PRI-1324 Indication: Nuts loose on clevis hanger Disposition: Accept as is '

i This support was previously examined during U1R13 with no recordable indications.

This indication would not have been recordable at this time. The clevis bolt has painted threads which prevent any movement of the nut. :The design requirements '

are that the threads be modified such that the nut is prevented from coming off. The  :

current configuration meets this design requirement. Therefore the indi:;ation is considered non-relevant per IWF-3410(b)(6). No additional or successive examinations are required.

Page 16 of 20 i

_ . , . . _ . _ ._.~ ._, -

'f i

E 'q

' Wisconse Elecerse Power Ca. l 231 West Michigan Avemme j

?4 Milwaukee WI 53201 .;

Point Beach Nuclear Plant. Unit ! ' -'

6610 Nuclear Road

. Two Rivers. WI 54241  ;

Docket 50-266 i

- Cornmercialservice Date 12/21no .  ;

95U1-7P007, Class 1 Rigid Support,45-05-PRA  :

Datasheet 95UI-754P071, Drawing ISI-PRI-1148 .

Indication: . Crack in paint, may extend into concrete  ;

Disposition: Accept as is This suppon was previously examined during U1R13 with no recordable indications.

Further evaluation of the indication reveals that the cracking does not extend into the . j concrete and is only paint cracking. This is considered a non-relevant indication.

No additional or successive examinations are required.

95Ul-7P008, Reactor Vessel Head to Flange (Az. 120-240), RPV-HFLANGE-B ,

Datasheet 95U1-350P015, Drawing ISI-PRI-1102 Indication: 1/8" linear indication in flange base material Disposition: Accept as is  ;

Examination of this weld was performed during the second interval with no  !

recordable indications. The previous datasheets indicated forging scale in the region I of this indication. The forging scale was removed for this examination. The forging  ;

scale would have masked this indication. Evaluation of this indication in accordance with the requirements of IWB-3510 was performed. The indication meets the '

acceptance criteria of ASME Section XI. No additional or successive examinations '

are required.

95U1-7P009, Class 2 Snubber, HS-01 I Datasheet 95U1-754PO44,' Drawing ISI-PRI-1261 Indication: Incomplete thread engagement  !

Disposition: Accept as is This snubber was previously examined during U1R13 and was reported no recordable indications. This type of indication would not have been recordable at that time.

The nut is tight and the incomplete thread engagement is not as a result of inservice degradation. There is sufficient thread engagen.ent on this and the remaining studs such that the strength of the bolted connection is more than adequate for the design of the snubber. No additional or successive examinat'ons are required.

95UI-7P010, Class 1 Rigid Suppon,37-09-PS .

Datasheet 95U1-754P069, Drawing ISI-PRI-1137 Indication: I-beam cut and rewelded. New weld not full length of the I-beam Disposition: Accept as is l 1

This suppon was not previously examined as this suppon was added to the long term  ;

plan as a result of the third ten year program upgrade. The indication in question is  !

l s

Page 17 of 20

. O . ik{

'F' Q$ " ' i I

Wa' ccessi Elecenc Power Co.~ . 6 231 West Michigan Avenue Milwaukee,WI S3201 Point Beach Nuclear Plant. Unit 1 6610NuclearRoad -

Two Rivers, WI $4241 '  !

Doemet 50-266 Conumercialservice Dese 12/2ino a fabrication related and is not as a result of inservice degradation. This weld was  ?

previously evaluated as acceptable. No additional or successive examinaticas are ,

required.  !

95UI-7P011, Class 2 Rigid Suppon, SI-55  :

Datasheet 95U1-754P030, Drawing ISI-PRI-1252 Indication: Rod not supporting pipe Disposition: Adjust rod to provide support for the pipe.

This support was previously examined in response to CR 91-094. It was reported no recordable' indications. This indication probably did not exist at this time. -The -

adjacent support was removed for a modification (MR 94-037). -This probably i caused a shift in the pipe in this region which caused the pipe support to loosen. All  ;

hardware on the support was tight indicating that nothing came loose from inservice ,

degradation mechanisms. A work order was submitted to tighten the eye-bolt on the  :

suppon so that the component was adequately supporting the pipe. No additional or successive examinations are required.

95Ul-7P012, Class 1 Rigid Suppon,45-07-PR Datasheet 95U1-754P070, Drawing ISI-PRI-1148 1 Indication: Elongated bolt holes and missing washer on wall plate j Disposition: Accept as is 1 This suppon was previously examined during U1R13 with no recordable indications. j This indication would not have been recordable at this time. The indication is ~'!

fabrication related and is not an inservice related degradation. None of the support -

items have loosened. The elongated hole was a result of the installation. There is no -

design requirement for washers to be present. No additional or successive examinations are required.

95Ul-7P013, Class 3 Rigid Support, H-17 Datasheet 95U1-754P027, Drawing ISI-PRI-1323 Indication:

l Loosened lock nuts  ;

Disposition: Tighten lock nuts '

This support was previously examined during U1R13 with no recordable indications.  ;

This indication would not have been recorded at this time. The locknuts are not ~ l tight, but cannot move because of the presence of painted threads. The loosened nuts does not affect the operability or function of the support. A work order was y submitted to tighten the nuts. The loose nuts are not as a result of inservice degradation. No additional or successive examinations are required.

1 I

Page 18 of 20  !

,g

_; ' Wisconam Electnc Power C4.

',C- 231 West Michigan Avesse , .

Milwaukee,WI 53201

[

Point Beach Nuclear Plaat. Unit I  ;

6610 Nuclear Road ';

+

. Two Rivers. WI 54241 ~

Docket 50-266 CommercialService Date 12/21/70

.' 1 95U1-7P014, Class 1 Closure Stud, RPV-STUD-23

.[

~

Datasheet 95U1-350P040, Drawing ISI-PRI-1103 Indication: Two (2) 0.5" linear indications Disposition: Accept as is  !

This stud was previously examined during U1R15. Because of the nature of the indication (stringer, slag-like appearance) the techniques used may have been different enough not to identify this indication or required that it be recordable.' The indication meets the acceptance criteria of IWB-3515.1(b). Therefore, no additional .i or successive examinations are required. >

95UI-7P015, Class 1 Closure Stud, RPV-STUD-24 Datasheet 95U1-350PO41, Drawing ISI-PRI-1103 Indication: 0.70" linear indication Disposition: Accept as is This stud was previously examined during U1R12. Because of the nature of the '

indication (stringer, slag-like appearance) the techniques used may have been '

different enough not to identify this indication or required that it be recordable.' :The -

indication meets the acceptance criteria ofIWB-3515.1(b). Therefore, no additional or successive examinations are required.

I 95U1-7P016, Class 1 Closure Nut, RPV-NUT-26 1 Datasheet 95UI-750P013, Drawing ISI-PRI-1103 -

Indication: Flattened threads in one region  !

Disposition: Accept as is  !

This nut was previously examined in the second ' ten year interval with no recordable indications. This indication may not have existed at the time. This indication was l documented with a VT-1 examination which is not required by the ASME Code.  ?

The visual examination was performed'to document a condition noted during the required surface examination. The surface examination was satisfactory with no recordable indications. The flattening of the threads probably occurred as a result of handling during maintenance. The condition does not affect the operability or  !

strength of the nuts therefore, no corrective actions are required. No additional or l successive examinations are required. I 3.2 Pressure Tegg 4

The following is a summary of recordable indications that required corrective actions:

Page 19 of-20

c. .
b. , 'l Wi.co.in Seeme Power C3 -

231 West Michigan Avenne -

j Milwaukee.WI 53201 Point Beach Nuclear Plant, Unit 1. i M10 Nuclear Road [

Two Rivers. WI 54241 Docket 50-2M - ,

ConunercialService Daae 12/21n0  ;

I IT-230, RC-00513A, RTD Manifold Flow Indicator Isolation  ;

Heavy dry white boric at packing / packing gland bolting. Boric acid was cleaned and '

packing adjusted under WO 9504399. Packing was not actively leaking during time of pressure test. No ASME Code corrective actions required.  !

3.3 Snubber Surveillance Tests ,

Tests were acceptable, no corrective actions required.-

i i

i l

-1 l

l l

i i

I l

l l

Page 20 of 20 l l

Wisconsin Sectric Power Ca.

e: 231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant, Unit 1 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-266 Conunercial Service Date 12/21/70 UNIT 1 REFUELING 22 REPAIR / REPLACEMENT

SUMMARY

REPORT .

FOR FORM NIS-2 Written by: N Date: [ ff Reviewed by: !u 25 b Date: B-7 6 Approved by Date: 7'N'

r :, L Wiscomun sieetne Power c2.

C 231 West Michigan Avenue Milwaukee,WI $3201 Point Beach Nuclear Plant, Unit I 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-266 Conunercial Service Date 12/21no Acronyms ASME . American Society of Mechanical Engineers CR Condition Report MR Modification Request MT Magnetic Particle Examination .

MWR Maintenance Work Request NDE Nondestructive Examination NRC Nuclear Regulatory Commission PBNP Point Beach Nuclear Plant PT Dye Penetrant Examination RT Radiographic Examination RRM Repair / Replacement / Modification UT Ultrasonic Examination VT Visual Examination WE Wisconsin Electric Power Company WO Work Order PAGE 2 of 8

I 9 3

m. .

Wisconse Electric Power C2.

231 West Mactugan Avenue .;

Milwaukee,WI 53201 '

Point Beach Nuclear Plant, Unit I 6610 Nuclear Road ,

~

Two Rivers WI 54241 l

'" '~

Docket 50-266

~ ConunercialService Das I5/21/70 Table of Contents

1.0 INTRODUCTION

-2.0 CODE CASES AND INTERPRETATIONS i i

3.0 ABSTRACT OF REPAIR / REPLACEMENT '

i e

~

= 1. m . , .

I i

i I

i i

i PAGE 3 of 8

Wisconsin Electnc Power C2.

231 West Michigan Avenue

- l Milwaukee.WI 53201 l

Point Beach Nuclear Plant, Unit 1 l 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-266 Conunercial service Date 12/21/70 UNIT 1 REFUELING 22 REPAIR / REPLACEMENT

SUMMARY

~~~

1.0 INTRODUCTION

From May 13,1994 to May 9,1995, repairs and replacements were performed on items at PBNP Unit 1. These repairs and replacements were completed in'the second examination of the second period, of the third 10-year interval at PBNP Unit 1. The time interval for this examination period included the Unit 1 Refueling 22 outage (UIR22) that ran from March 11,1995 to April 19, 1995.

2.0 CODE CASES AND INTERPRETATIONS This report utilized the following Code Cases and Interpretations:

2.1 ASME Code Interpretation, Section VIII-1-83-17, which allows for computer generated data report forms to be used in place of Code forms as long as size, arrangement, and content are identical.

3.0 ABSTRACT OF REPAIR / REPLACEMENT 3.1 Repairs / replacements performed on ASME Class 1 and 2 items are documented on the attached NIS-2 forms. Repairs / replacements on ASME Class 3 items are documented on NIS-2 forms and maintained on file at PBNP. They are not included in this report in accordance with ASME Section XI, IWA-6210(c).

RRM 94-0039, MWR 9402137, MR 94-096 COMPONENT: RC-00558 CLASS: 1 DESCRIPTION: Replace RC-558 RC-558 was removed from the system and replaced with a straight section of pipe for maintenance '

reasons (also see RRM 95-0003).

RRM 94-0081, MR 94-037 COMPONENT: Miscellaneous supports CLASS: 2 DESCRIPTION: Reinforce / shim supports in accordance with MR 94-037 Pipe supports 1H-200,1-S464,2-H202,4-S2 and 2-H51A were modified by adding shims and reinfortement in accordance with MR 94-037 in response to IE Bulletin 79-14 walkdowns.

PAGE 4 of 8

4 4 Wisconsa Elecenc Power Ca.

231 West Machigan Avenue  !

MGwaukee,WI $3201  !

Point Beach Nuclear Plant. Unit 1

- 6610 Nuclear Road Two Rivers. WI 54241 l Docket 50 266  :

ConumercialserviceDese 12/2!00 -  ;

RRM 94-0082, MR 94-037 COMPONENT: Pipe suppons.1-HIA,2-H15 and 2-H8 '~

CLASS: 2  !

DESCRIPTION: Modify supports in accordance with MR 94-037 The spring support on Pipe support 1-HIA was removed and the lateral restraint on pipe supports 2-H15 and 2-H8 were removed in accordance with MR 94-037 in response to IE Bulletin 79-14 walkdowns.

~'

RRM 94-0083, MR 94-037 COMPONENT: Miscellaneous pipe supports  ;

CLASS: 2 '

DESCRIPTION: Modify pipe supports in accordance with MR 94-037 i Pipe Supports 3-S845,2-S845,1-H3,1-H1,3-2H1, and 2-2H1 were modified in accordance with MR 94-037 in response to IE Bulletin 79-14. Modifications were made to upgrade supports to meet piping design requirements. ,

RRM 94-0086, WO 9500089 COMPONENT: HX-001A . - _ _ _ . . _

DESCRIPTION: Repair steam cut in handhole  ;

Steam leak developed at Steam Generator handhole gasket. Machined gasket flange and installed new gasket design.  !'

RRM 95-0003, MWR 9411833, MR 94-096 '

COMPONENT: RC-503, RC-541, RC-598 and RC-599 CLASS: 1  !'

DESCRIPTION: Remove valves from system and replace with welded connections Removed valves RC-503, RC-541, RC-598 and RC-599 from the RCS and replaced with welded l

connections for maintenance reasons (also see RRM 94-0039).

RRM 95-0010, MWR's 9500299 & 9500300 COMPONENT: PS AC-152N-4-AC9 and PS AC-152N-4-R157 CLASS: 2 DESCRIPTION: Modify piping supports Pipe supports modified as part of the IE Bulletin 79-14 program.  ;

RRM 95-0011,' MWR 9500475 i

. COMPONENT: P-116 CLASS: 2 ~

DESCRIPTION: Replace suppon head on P-116 The suppon head on the boric acid recirculation pump (P-116) was replaced due to corrosion from' PAGE 5 of 8

s

. ;, y 4 Wiscossan Elecine Power CD.

T 231 West Michigan Avenue Mawaukee.WI 53201 Point Beach Nuclear Mant. Unit ! .

~6610 Nuclear Road Two Rivers. WI 54241 Docket 50-266 Commercial service Dese 12/21/70 boric acid leaks. ' Boric acid leaks were conected.

RRM 95-0012, WO 0402926 _

COMPONENT: HX-003B CLASS: 2 DESCRIPTION: Replaced end bell stud Replaced end bell stud on Non-regenerative heat exchanger (HX-003B) due to boric acid corrosion.

RRM 95-0014, WO 893697 ~

COMPONENT: P-004A CLASS: 2 DESCRIPTION: Replaced pump, studs and nuts Replaced boric acid transfer pump (P-004A) due to damage. - In addition, replaced the studs and nuts associated with this pump installation l.

RRM 95-0015, WO 892905 COMPONENT: P-004A/B i CLASS: 2 DESCRIPTION: Rebuild spare pump for stock l Spare boric acid transfer pump rebuilt.  !

RRM 95-0016, WO 9407493 -

COMPONENT: P-002B CLASS 2 ~ ~

DESCRIPTION: Replace stuffing box on charging pump .

Pump had excessive seat leakage and required stuffing box replacement. Stuffing box considered a ,

pressure retaining component. Inservice leak test performed but not properly documented on - 'I correct form. This non-conformance is documented on Condition Report 95-0395. '

RRM 95-0019, WO 9502834 COMPONENT: HX-003B

' CLASS: 2 DESCRIPTION: Replace studs / nuts on end nell Replaced 14 studs and corresponding nuts because of corrosion damage. Source of corrosion corrected. Inservice leak test performed but not properly documented. This non-conformance is documented on Condition Report 95-0395.  !

4 RRM 95-0020, WO 9411648

)

COMPONENT: PS AC-152N-5-SBH-27 CLASS: 2 'I DESCRIPTION: Install new support New support installed on Component Cooling water (CCW) piping as part of a seismic upgrade of PAGE 6 of 8

' '4 1 4 Wisconsin Elecenc Power Ca.

,- ' 231 West Machagan Avenue Milwaukee.WI $3201 Point Beach Nuclear Plant. Unit 1 6610 Nuclear Road Two Rivers. WI 54241

' Docket 50-266 '

conumercial service Dane 12/21n0

- the CCW system inside containment.

~~

RRM 95-0021- WO 9411648 ,

COMPONENT: PS AC-152N-SBH-il and PS AC-152N-SBH-45 CLASS: 2 ~

DESCRIPTION: Remove piping :;upports from the system.

Remove two supports from the Component Cooling water (CCW) piping as part of a seismic upgrade of the CCW system inside containment.

RRM 95-0022, WO 9503140 COMPONENT: CV-00110C CLASS: 2 DESCRIPTION: Replace pneumatic operator with manual operator Replaced pneumatic operator on valve CV-110C with a manual operator until a replacement .

pneumatic operator could be installed (also see RRM 95-0026).

RRM 95-0026, WO 9503186 COMPONENT: CV-00110C _. _ .

CLASS: 2

' DESCRIPTION: Replace operator with new pneumatic operator.-

Installed pneumatic operator on valve CV-110C to return it to original design configuration. ,

RRM 95-0028, WO's 9403457 & 9503286 l

COMPONENT: RC-00431C CLASS: 1 - _ _

DESCRIPTION: Replace trim assembly and yoke to bonnet bolts Replaced trim assembly and yoke to bonnet bolts on RC-00431C because of valve leak by.

RRM 95-0029, WO 9501560 COMPONENT: MS-2016 CLASS: 2 DESCRIPTION: Replace cage locking device Replaced cage locking device on MS-2016. New cage locking device is installed by welding to valve body.

RRM 95-0030, WO 9402258 COMPONENT: MS-2015

~

CLASS: 2 DESCRIPTION: Replace cage locking device Replaced cage locking device on MS-2015. New cage locking device is installed by welding to valve body.

PAGE 7 of 8

14)

I Wisconsin Electnc Power C3 231 West Michigan Avenue Milwaukee,WI 53201 Point Beach Nuclear Plant. Unit I 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-266 Commercial service Date 12/21/70 F RRM 95-0032, WO's 9503190 arb 9503191 l - COMPONENT: SI-00854A and SI-00854B _

f CLASS: 2 ~

L DESCRIPTION: Replace seat and disk b

. Installed new seat and disks in valves SI-00854A/B because of seat leakage in valves.

RRM 95-0034, WO 926586 COMPONENT: CV-00203

! CLASS: 2 DESCRIPTION: Replace relief valve with spare due to leakage l Replaced letdown orifice relief valve CV-00203 with spare.

l l

l l

l i '

. I i

i PAGE 8 of 8

7 ,

i l

i FORM NIS-2 OWNER'S REPORT FOR REPAfRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date April 14.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address *
2. PlantPoint Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 MR 944)96 Address Repair Organizanon P.O. No., Job No., etc.
3. Work Preformed By Phillios-Getschow Type Code Symbol Stamp N/A Name Authorization No. N/A 2860 Glenmore road. Green Bay. WI 54311 Expiration Date N/A Address
4. Identification of System Reactor Coolant
5. (a) Applicable Construction Code USAS B31.1 19 67 Edition, N/A Addenda. N-7 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code '

Name of Name of Manufacturer - Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No) i RC-00503 N/A N/A N/A RC-503 N/A Replacement No RC-00541 N/A N/A N/A RC-541 N/A Replacement No RC-00598 N/A N/A N/A RC-598 N/A Replacement No RC-00599 N/A N/A N/A RC-599 N/A Replacement No RC 00558 N/A N/A N/A RC-558 N/A Replacement No

7. Description of Work Remove RCS A&B 1200 drain valves and RC-558
8. Tests Conducted: 11ydrostatic R* Pacumatic O Nominal Operating Pressure O Other O Pressure osi Test Temp. 'F Surface exam PT
  • - in accordance with plant Technical Specifications NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) ' Ibis Form (E00030)may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

s

.w Sheet 2 of _2_,  !

l Form NIS-2 Continued

9. - Remarks RRM 95-0003. 04-0039 Applicable Manufacturer's Data Reports to be attached l

l l

l I

CERTIFICATE OF COMPLIANCE

{,

l We certify ti ? rhe statements made in the report are correct and this Reolacement conforms to the rules of the Af,Me ude,Section XI. repair or replacernent Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A Signed i TCfi Coordder Date _

2Y 19 9f Owner or Owner's Designee, Tide #

[

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 _ to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector cor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection.

Commissions /8 M /, W/ N

/ Insglector's SigInture i

National Board,'Srate. Province, and Endorsements Date ,

O/ 19fk,,,_

c . _ .

r ITiRM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Swtion XI '

l. Owner Wisconsin Electric Power Company Date January 12.1995

^

Name 231 W. Michiran Ave. Milwaukee WI 53201 Sheet 1 of 2 Address

2. Plant Point Beach Nuclear Plant Unit 1 Nanw 6610 Nuclear Road. Two Rivers. WI 54241 MR 94-037 I Address '

Repair Organization P.O. No., Job No., etc.

3. Work Preformed By Phillios-Getschow Type Code Symbol Stamp N/A Name Authorization No. N/A 2860 Glenmore Road. Green Bay. WI 54311 Expiration Date N/A Address
4. Identification of System Component Cooline Water Bechtel Spec M-78
5. (a) Applicable Construction Code AISC 6th Edition 19 N/A Edition, N/A Addenda None i Code Ca*e ,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda '

i

6. Identification of Components Repaired or Replaced and Replacement Components i

l Repaired, ASME I National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Idenufmation 1

Built Replacement (Yes or No) 111 200 N/A N/A N/A N/A N/A Replacement No  !

1 5464 N/A N/A N/A N/A N/A Replacement No 211202 N/A N/A N/A N/A N/A Replacement No 4-S2 N/A N/A N/A N'A - N/A Replacement No 2.ll51 A N/A N/A N/A N/A N/A Replacement No

7. Description of Work Jteinforce/ shim sunoorts in accordance with MR 94-037
8. Tests Conducted: Ihwestatic O Pneumatic O Nominal Operating Pressure 0 0.her lii5 Pressure osi Test Temp. *F Visual NOTE: Supplemental sheets in form oflists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept.. ASME, 345 E. 47th St., New York, N.Y.10017 l

l t

m

Sheet 1 of 2 Form NIS-2 Continued

9. Remarks 94-0081 Apphcable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of uthorization No. Docket 50-266 Expiration Date N/A Signed A A '

UI la'/MNd/ Date. Na4 /7 19 7 Owner or Owner's Designee. Tide CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hanford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the lospector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fmm or connected with this inspection.

/~ / Inspector's Signature Commissions /o75/ . WI 7 Ef . l ^/s b Nanonal Board, State Province, and Endorsements Date N4v 2d 19 9?:>

i l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Comoany Date December 12. 1994 Name 231 W. Michigan Ave. Milw=nkaa WI 53201 Sheet 1 of 2 Address
2. PlantPoint Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 MR 94-037 Address Repair Organuation P.O. No., Job No., etc.
3. Work Preformed By Phillios-Getschow Type Code Symbol Stamp N/A Name Authorization No. N/A 2860 Glenmore road. Green Bay. WI 54311 Expiration Date N/A Address
4. Identification of System Safety Iniection Bechtel Spec M-80
5. (a) Applicable Construction Code AISC 6th Ed. 19 N/A Edition. N/A Addenda, None Code Case (b) Applicable Edition of Section XI Utilized for Repain or Replacements 19 86. no =Ma~ia
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Componem Manufacturer Serial No. No. Identification Built Replacement (Yes or No) 1-HI A N/A N/A N/A IH-01 A N/A Replacement No 2 H15 N/A N/A N/A SI-55 N/A Reat nt No 2 118 N/A N/A N/A SI-47 N/A Replacement No i l

1

)

7. Description of Work Remove sprine suonort on 1-HI A and remove lateral restraint on 24115 and 2-H8
8. Tests Conducted: Ilydrostatic O . Pneumatic O Nominal Operating Pressure O
l. Other R Pressure osi Test Temp. 'F l VT-3 (All supports)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

I x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is L

numbered and the number of sheets is recorded at the top of this form.

(12/82)

.as Form (E00030) may be obtained from the Order Dept. ASME, 345 E. 47th St., New Yort. N.Y.10017 I

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 94 0082 Applicable Manufacturer's Data Reports to be anached CERTIFICATE OF COMPLIANCE l i

We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code,Section XI. repair or replacement i

Type Code Symbol Stamp N/A l

Certificate of Authorization No. Docket 50-266 Expiration Date N/A I Signed III 0'UM" Date de 19 Owner or Owner's Designee. Title 8 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 , and state that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner fer any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions lOY3I, WIIVe Ir No tnspector's Squature Nanonal Board, State. Province, and Endorsements Date Mw 7I 19 Sd-

l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACE!!FNTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date December 13.1994 l Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of _ 2 Address l
2. PlantPoint Beach Nuclear Plant Unit 1 1 Name 6610 Nuclear Road. Two Riven. WI 54241 MR 94-037 i Addreas Repair Organnarian P.O. No., Job No., etc. 1 I
3. Work Preformed By Phillios-Getschow Type Code Symbol Stamp N/A Name Authorization No. N/A 2860 Glenmore road. Green Bay. WI 54311 Expiration Date N/A  ;

Address '

4. Identification of System Safety Inlection Bechtel Spec M-80 l
5. (a) Applicable Construction Code AISC 6th Ed. 19 N/A Edition, N/A Addenda. None Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components j

l

\

Repaired, ASME-  !

National Replaced. Code i Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identificanon Built Replacement (Yes or No) 3-S845 N/A I N/A N/A SI-41 N/A Replacement No 2 5845 N/A N/A N/A SI-23 N/A Replacement No 1-113 N/A N/A N/A IH43A N/A Replacement No 1-111 N/A N/A N/A IH41B N/A Replacement No 3-2HI N/A N/A N/A 2H41D N/A Replacement No 2 2HI N/A N/A N/A 2H41E N/A Replacement No

7. Description of Work Modify sunoorts in accortinnce with Mod Reauest 94 037 GEB 79-14 orogram)
8. Tests Conducted: Hydrostatic O Pneumatic 0 Nominal Operating Pressure O l

Other DC Pressure osi Test Temp. 'F '

VT-3 (All supports)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.  !

l (12/82) This Form (E00030) may be obtamed imm the Order Dept.. ASME, 345 E. 47th St.. New York. N.Y.10017 I

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 94-0083 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this __ Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Cenificate of Authorization No. Docket 50-266 Expiration Date N/A Signed  % c MT b'f/h/3' Date 4 /d , 19 95 Owner or Owner's Designee Tide I

CERTIFICATE OF INSERVICE INSPECTION  !

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hanford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 , and state that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective

{

measures described in this Owner's Report in accordance with the requirements of the ASME Code,  !

Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Rt.pon.

Funhermore, neither the Inspector nor his employer shall be liable in any taanner for any personal injury or propeny damage or a loss of any kind arisirig from or connected with this inspection.

_ Commissions /073 /. k[I 7E# ,T -

/ InIpector's Signature Nanonal Board, State, Province, and Endorsernents Date b 19 Tb'

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Comnany Date Antil 14.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet I of 2 A& tress
2. Plant /oint Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9500089 Addreas Repair Organization P.O. No., Job No., etc.

g

3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Main Steam
5. (a) Applicable Construction Code ASME III 19 77 Edition, W78_ ,. Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Idenafication Built Replacement (Yes or No)

HX401A Westmghouse N/A 16A60791 N/A 1983 Repair Yes

7. Description of Work Renait steam leak on handhole.
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure E Other O Pressure osi Test Temp. *F IT-230 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I l

(12/82) 1his Form (E00030)may be obtained from the Order Dept., ASME. 345 E. 47th St., New York. N.Y.10017 i

l l

L

'a Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 94-0086 Apptr.able Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this Renair conforms to the rules of the ASME Code,Section XI. repair or replacernent i

Type Code Symbol Stamp N/A l

1 Cenificate of Authorization No. Docket 50-266 Expiration Date N/A l Signed b ' '

Od/ Ad' Date 8'*fet! 7 ,19 f Owner or Owner's Designee. Title #

CERTIFICATE OF INSERVICE INSPECTION j i

1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co, ,

of Hartford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 {

, and state  !

that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

l By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exammations and corrective measures described in this Owner's Report.

Funbermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a 1 s of any kind arising from or connected with this inspection.

4 Commissions /[bs

/ Insp6ctor's Signature National Board, State, Province. and Endorsements Date ** P< s f 19 Ib

l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

)

1. Owner Wisconsin Electric Power Company Date April 7.1995 Name 231 W. Michican Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant "'it 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 /O 9500299.9500300 Addren Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Component Cooline Water 1
5. (a) Applicable Construction Code ANSI B31.1 19_QLEdition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

PS AC-152N4-AC9 N/A N/A N/A AC9 N/A Replacement No PS AC 152N4-R157 N/A N/A N/A R157 N/A Replacement No l

l

7. Description of Work Modification of oioine supports AC9 and R157
8. Tests Conducted: Hydrostatic 0 Pneumatic O Nominal Operating Pressure O Other E Pressure psi Test Temp. 'F Visual l

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is j numbered and the number of sheets is recorded at the top of this form.

(12/82) *This Form (E00030) may be obtained from the Order Dept., ASME 345 E. 47th St.. New York, N.Y.10017

l l

i Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95-0010 Appbcable Marmfacturer's Data Reports to be anached CERTIMCATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the tules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A Signed Ars Y M Coorkmbe Owner'or Owner's Desiguce. Tide Date

-  % 19 W CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/'

k ~

In$ector's Signature Commissions /d7 ?/ , N 7b A National Board State. Provirw.e. and Endorsements Date bsusl 3 19ff I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Pavvisions of the ASME Code Section XI

1. Owner Wiscomin Electric Power Company Date February 17.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 1 Name #8" 6610 Nuclear Road. Two Rivers. WI 54241 MWR 95/00475 Address Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical and Volume Control System
5. (a) Applicable Construction Code USAS B31.1 19 67 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Nanonal Replaced, Code  !

Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacemen: (Yes or No)

P-Il6 N/A N/A N/A N/A N/A Replacement No I

7. Description of Work Replace support head on pumo P-116
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure Fd Other O Pressure osi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l (12/82)

This Form (E00030) anay be obtamed fmm the Order Dept.. ASME. 345 E. 47th St., New York, N.Y.10017

i Sheet 2 of 2 1 1

Form NIS-2 Continued I l

9. Remarks RRM 954)11 Appleable Manufacturer's Data Repons to be attached l

l 1

l CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this _ Replacement conforms to I the rules of the ASME Code,Section XI. repair or replacernent Type Code Symbol Stamp N/A Cenificate of Authorization No. Docket 50-266 Expiration Date N/A Signed ISI (dD40/AM77R Date .N 19 78 Ow' ner or Owner's Designee. Title #

[

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by IISBil. Co.

of flattford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection.

/ Insp6ctor's Signature Commissions /0 YN t Wl?V i U' A National Board, Scare, Province, ard Endorsernents Date b usVS-L 19 9 f I

' a

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Comoany Date April 14.1995 Name l

231 W. Michinan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address

2. Plant Point Beach Nuclear Plant- Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9402926 Addreu Repair Organization P.O. No., Job No., etc.

l l

3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Addreu
4. Identification of System Chemical and Volume Control West. E-Spec 676228 Rev. 0
5. (a) Applicable Construction Code 19_ Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda l 1
6. Identif"ication of Components Repaired or Replaced and Replacement Components  ;

Repaired. ASME National Replaced. Code Name of Name of Marasfacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Rer% cement (Yes or No)

IIX@3B Sentry N/A 0338 U010596 1968 Replacement Yes I

7. Description of Work Replaced end bell stud on non-recenerative heat exchanner
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure liR Other O Pressure osi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in iteus 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030)may be obtained from the Order Dept.. ASME. 345 E. 47th St., New York. N.Y.100t7

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95-0012 Applicable Manufacaner's Dara Reports to be attached P

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A l Signed _ M 37 (comO4h Date 7 ,19 if

" bwner or Owner's Designee Titic ' '

l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exammations and corrective measures described in this Owner's Repon.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/ Inspector's Signature Commissions l0Y3l o W'? V . A !b Nanonal Board, State. Province, and Endorsements i

Date us 7 19 75'

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date February 17.1995 Name 231 W. Michiran Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Rood. Two Rivers. WI 54241 WO 893697 Address Repair Orgsmnema P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical and Volume Control Westinghouse Spec 676372
5. (a) Applicable Construction Code ANSI B31.1 19,67 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacmrer Serial No. No. Idenafication Built Replacement (Yes or No)

P404A N/A N/A N/A N/A N/A Replacement No

7. Description of Work Replaced P-004A.
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O Other tit Pressure osi Test Temp. 'F IT-17 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) his Fonn (E00030)may be obtamed from the Order Dept. ASME. 345 E. 47th St., New York. N.Y.10017

Sheet 2 of 2 i

Form NIS-2 Continued i 1

9. Remarks RRM 95-0014 Applicable Manufacturer's Data Reports to be attached I

. _ CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A Signed A44 MI dDate 4 3/ 1998 6 ner # owner . Designee Titi.

[ '

CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by . HSBil. Co.

of Hanford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 , and state .

that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective l

measures described in this Owner's Report in accordance with the requirements of the ASME Code, '

Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or

{

implied, concerning the examinations and corrective measures described in this Owner's Report.

1 Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or l propeny damage or a loss of y kind arising from or connected with this inspection. I Commissions /d 78 , N Y ,

[ In/pector's signature E

National Boani, State. Province, and Endorsements Date

$M 19 I

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date Febmary 28.1995 Name 231 W. Michinan Ave. Milwankaa WI $3201 Sheet 1 of 2 i Address
2. Plant Point Beach Nuclear Plant Unit i Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 892905 Address Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical and Volume Control
5. (a) Applicable Construction Code ANSI B31.1 19,67 Edition, N/A Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No) ,

P M A/B N/A N/A N/A N/A N/A Replacement No

7. Description of Work Rebuilt spare pump for P-004A/B
8. Tests Conducted: llydrostatic O Pneumatic O Nominal Operating Pressure O Other M Pressure osi Test Temp. *F None Required NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) 1his Form (E00030) may be obtained from the Order Dept., ASME 345 E. 47th St., New York. N.Y.10017

Sheet 2 of 2' I Form NIS-2 Continued

9. Remarks RRM 95-0015 Applicable Manufacturer's Data Repom to be sanched CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A i

I I

Cenificate of Authorization No. Docket 50-266 Expiration Date N/A l Signed /fh> .T5S Ce*Andledr Date 8/ 19 9F

' Owner or Owner's Designee. Title [/ #

CERTIFICATE OF INSERVICE INSPECTION J

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection.

Commissions /d7J/ , WI78 Ir A4 4

/ Inspector's Signature National Board, State. Province, and Endorsements Date Ic od j 19 75'

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l As Required by the Provisions of the ASME Code Section XI

{

l. Owner Wisconsin Electric Power Company Date february 24.1995 Name <

l 231 W. Michican Ave. Milwaukee WI 53201 Sheet 1 of 2 Address I

2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9407493 Address Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical and Volume Control Westinghouse Spec. 676370
5. (a) Applicable Construction Code ANSI B31.1 19 bl Edition, N/A Addenda, N/A Code Case ,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda l

6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced.

)

Code 1 Name of Name of Manufacturer Board Othrt Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes '

or No)

P4X)2B N/A N/A N/A N/A N/A Replacement No I

l

7. Description of Work Replaced stuffine box on charcine pumo P-2C l
8. Tests Conducted: Ilydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other B Pressure osi Test Temp. 'F IT-21 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) " Ibis Form (E00030) may be obtained fmm the Order Dept., ASME,345 E. 47th St., New York, N.Y. t0017

e Sheet 2 of 2 Fonn NIS-2 Continued

9. Remarks RRM 954016. Condition Report 954395 written on improper documentation of nressure test Applicable Manufacturer's Data Reports so be anached results CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or reptacernent Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A i

Signed 84% 4 / IIbO?IAf/b Date @/ [ 19 N

'Ownir or Owner's Designee, Title

/

i l

l CERTIFICATE OF INSERVICE INSPECTION j

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed exanunations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer snati De liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~-

/ tnipector's Signature Commissions /dN i b ' '

Nanonal Board, State. Province, and Endorsements Date ec+f ' 19 7 I

a FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Comnany Date April 14.1995 Name 231 W. Michican Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9502834 Address Repair Orgamzanon P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of Systern Chemical and Volume Control West. Spec 676228
5. (a) Applicable Construction Code 19_ Edition, None Addenda. None Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME Nanonal Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Idenafication Built Replacement (Yes or No)

HX m3B N/A N/A NB0338 U0105% N/A Replacement Yes

7. Description of Work Renlaced 14 studs on endbell at non-recenerative heat exchancer.
8. Tests Conducted: liydrostatic O Pneumatic O Nominal Operating Pressure Q Other O Pressure nsi Test Temp. *F l

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

j (12/s2) nis Forin (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017

.c Sheet 2 of 2 Fonn NIS-2 Continued

9. Remarks RRM 95-0019. Condition Report 95-0395 written on improper documentation of oressure test Applicable Manufacturer's Data Repons to be attached results CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A Signed @ b[ b/l // P Date ll#f// F ,19 e

" Owner or Owner's Designee. Tide '

CERTIFICATE OF INSERVICE INSPECTION 1, the undenigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by _ HSBII. Co.

of_ Hartford. CT _

have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injur property damage or a loss of any kind arising from or connected with this inspection.

Commissions /OU[# MY, 1

/ fnspecier'sSignature National Board. State. Province, and Endorsements Date Nwar [ 19 6

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date April 14.1995 Nane 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9411648 Address Repair Orgamzation P.O. No. Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Component Cooline Water
5. (a) Applicable Construction Code ANSI B31.1 19_QLEdition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME tJational Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

AC 152N4-SBH-il N/A N/A N/A N/A N/A Replacement No (Removed)

AC-152N4-SBH45 N/A N/A N/A N/A N/A Replacement No (Removed)

AC-152N-5-SBH-27 N/A N/A N/A N/A N/A Replacement No (Added)

7. Description of Work Remove two supports and install new support on component cooline water nioine.
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O Other M Pressure osi Test Temp. *F None NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) "Ihis Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.10017

y Sheet _2_, of 2 Form NIS-2 Continued

9. Remarks __RRM 95-0020. 95-0021 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this __ Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docks 50-266 Expiration Date N/A Signed TI.T tawa8*4hr Date f

3 19 fl bwner or Owner's Designee, Tide CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of an kind arising from or connected with this inspection.

t Commissions /878/ e El 7I. 1 49

[' Inadector's Sfnature Nanonal Board. State. Province, and Endorsements Date ( ;us b 7 19 W

l l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

1. Owner Wisconsin Electric Power Comnany Date March 28.1995 l Narne

)

231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 , I Address '

2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9503186. 9503140 Address Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical and Volume Control West. E-Spec 676270,676281
5. (a) Applicable Construction Code 19.,_ Edition, None Addenda, None Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Idersfication Built Replacement (Yes or No)

CV-00110C N/A N/A N/A CV-Il0C N/A Replacement No P

7. Description of Work Replaced valve bonnet and operator for CV-Il0C.
8. Tests Conducted: liydrostatic O Pneumatic O Nominal Operating Pressure E Other O Pressure osi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the to,p of this form.

(12/82) This Form (E00030) may be obtained from the Order Dept., ASME 345 E. 47th St., New York, N.Y.10017

)

l

)

I

. l Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 954X122. 954)026 Apploable Manufacturer's Data Repons to be attached a

CERTIFICATE OF COMPLIANCE We certify that the statements inade in the report are correct and this Replacement conforms to the m!cs of the ASME Code,Section XI. npair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A Signed AA< / fff GeMMr Date 3/ ,19 Y lowner for Owner's Designee. Tide /

[

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of llanford. CT have inspected the components described in this Owner's Report during the period May 13.1994 to May 9.1995 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspmor nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

T,4 A

~

/

/ Commissions l00l r N' ?E'r Inspector's Signature National Board, State. Province, and Endorsements Date Mf 19 W i

l l

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Comoany Date April 14.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9403457. 9503286 Address Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Reactor Coolant West. Spec E676270
5. (a) Applicable Construction Code 19_ _ Edition, None Addenda, None Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19h addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced, Code Name of Name of l Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

RC@431C N/A N/A N/A RC-431C N/A Replacement No l l

7. Description of Work Replace trim assembly and voke to bonnet bolts on RC-431C
8. Tests Conducted: Hydrostatic lib
  • Pneumatic 0 Nominal Operating Pressure O Other O Pressure osi Test Temp. 'F
  • - in accordance with plant Technical Specifications NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. l x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is }

numbered and the number of sheets is recorded at the top of this form.

f (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York. N.Y.10017 l

l l

c l

l Sheet 2 of 2 Form NIS-2 Continued  !

l

9. Remarks RRM 95-0028 Applicable Manufacturer's Data Repons to be anached i

CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A C:nificate of Authorization No. Docket 50-266 Expiration Date N/A Signed As V ff ,,vg,,8 Desisnee. Title 1w Gma/JnDate <.b. 3/ .19 V f /

1 CERTIFICATE OF INSERVICE INSPECTION J

l I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesse!  !

Inspectors and the State or Province of Wisconsin and employed by . HSBII. Co,  !

of Hartford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or I implied, concerning the examinations and corrective measures described in this Owner's Repon.

Funhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising frcm or connected with this inspection. I

~-

Commissions f6 7]/, lA' H 7 2' , N /?

/ Inspector a sisnature National Board, State Province, and Endorsements Date b $er r b -?- 19 V f

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I

l

1. Owner Wisconsin Electric Power Comnar.v Date April 30.1995 Name l

2,11 W. Michiran Ave. Milwaukee WI 53201 Sheet 1 of 2 i Address i

2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54741 WO 9501560 l

Address Repair Orgamzanon P.O. No., Job No., etc.

l l

3. Work Preforned By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A
  1. 610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Main Steam Bechtel Spec 6118-M 185
5. (a) Applicable Constructian Code 19_ Edition. N/A,, Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs irr Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced, Code Name of Narne of Manufacturer Board Other Year or Stamped Component Manufacturer Senal No. No. Idenuficanon Built Replacement (Yes or No)

MS-2016 N/A N/A N/A N/A N/A Replacement No l

7. Description of Work Grind off and replace new care lockine device for valve trim
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O Other K Pressure osi Test Temp. 'F IT-90 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

I 11 in., (2)information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This Form (E00030) may be obtamed from the Order Dept., ASME. 345 E. 47th St., New York, N.Y.10017

c. . .;

l Sheet 2 of 2 l

Form NIS-2 Continued f

9. Remarks RRM 95-0029 i Applicable Manufacturer's Data Reports to be anached b

i CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacemen:

Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-266 Expiration Date N/A  :

Signed d(T 4ser/r'Aed Date bk' M 19 9 'T'

' Owner'or Owner's Dessnee, Tide /

' l CERTIHCATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesse!  !

Inspectors and the State or Province of Wisconsin and employed by HSBil. C).

of_,llanford. CT have inspected the components described in this  !

Owner's Repon during the period May 13.1994 to May 9.1995 , and state l that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective measures described in this Owner's Repon in accordance with t!'e requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examiations and corrective measures described in this Owner's Repon.

s Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or l

propeny damr;',e or a loss of any kind arising from or connected with :his inspection.

N ,, / k F

i&pector's Signantre Commissions M U. N' Y.

Nauonal Board, State. Province, and Endorsements l

Date byN$ 19 Y i

I J

1 ORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power comoany Date April 30.1995 Name 231 W. Michiran Ave. Milwaukee WI 53201 Sheet 1 of 2 Addresa
2. Plant Point Beach Nuclear Plant Unit i Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9402258 Address Repair Organization P.O. No., Job No., cic.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Main Steam Bechtel Spec 6118-M-185
5. (a) Applicable Construction Code 19 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components

' Repaired, ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Senal No. No. Identifcation Built Replacement (Yes or No)

MS42o15 N/A N/A N.A MS-2015 N/A Replacement No

7. Description of Work Replace care locking device on MS-2015
8. Tests Conducted: liydrostatic O Pneumatic O Nominal Operating Pressure O Other EiD Pressure osi Test Temp. 'F IT-90 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fonn.

(12/82)

This Form (E00030)may be obtained from the Order Dept., ASME,345 E. 47th St., New York. N.Y.10017

.s Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95-0030 l

Applicable Manufacturer's Data Reports to be anached CERTIFICATE OF COMPLIANCE We cenify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Cenificate of Authorization No. Docket 50-266 Expiration Date N/A Signed &f effu~.

' Owner or Owner's Designee, Title M ter//4 Date

/

v k# 2 7 ,19 9 7 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by . HSBII. Co.

of Hanford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed exammations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/ tnsfector's Signature Commissions /6 7M M/ Y, Nanonal Board. State. Province, and Endorsements 1

Date y us 2.- 19 ff u

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date March 28.1995 Name 231 W. Michican Ave. Milwaukee WI 53201 Sheet I of 2 Address
2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 9503191. 9503190 Address Repair Orgamzation P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Safety Iniection
5. (a) Applicable Construction Code ANSI B16.3419JB_ Edition, N/A Addenda, N/A Code Case -

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stam,ed Component Manufacturer Serial No. No. IdentiDcation Built Replacement (Yes or No)

S1410854A N/A N/A N/A SI-854A N/A Replacement No

{

S14)0854B N/A N/A N/A SI-854B N/A Replacement No 1

7. Description of Work Replace valve seat and disks on SI-854A/B
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O Other 50 Pressure psi Test Temp. 'F IT-530 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. I x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)  !

This Form (E00030)may be obtamed from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 20017

l I

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 954)032 Applicable Manufacturer's Data Reports to be anached l

CERTIFICATE OF COMPLIANCE We cenify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Cenificate of Authorization No. Docket 50-266 Expiration Date N/A Signed 16 (8#f8 Date 7- 19 N Owner or Owner's Designee, Title #

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

of 11anford. Q have inspected the components described in this Owner's Repca fering the period May 13.1994 to May 9.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon. j Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or l

prop < rty damage or a loss of any kind arising from or connected with this inspection.

i Commissions /d U / , M /7P. IMA

/ Insi fector's Signature Natmnal Board, State. Pmvince, and Endorsernents !

Date %d2 1995~

F g 4-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Comoany Date April 5.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address

' 2. Plant Point Beach Nuclear Plant Unit 1 Name 6610 Nuclear Road. Two Rivers. WI 54241 WO 926586 Address Repair Organization P.O. No., Job No., etc.

3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical and Volume Control West. E-Spec 676257
5. (a) Applicable Construction Code 19_ Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. ' No. Idenufication Built Replacement (Yes or No)

CV-00203 Crosby N/A N/A CV-203 N/A Replaced No

7. Description of Work Replace CV-203 with soare relief valve
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure E Other O Pressum nsi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) Ttus Form (E00030)may be obramed from the Order Dept., ASME,345 E. 47th SL New York, N.Y.10017

m ,

, 1 &

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95-0034 Apphcable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the repon are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Cenificate of Authorization No. Docket 50-266 Expiration Date N/A Signed i ! IIJ (ae r//ne/pr Date /9 26 19 fr' Owner or Owner's Designee. Tide CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hanford. CT have inspected the components described in this Owner's Repon during the period May 13.1994 to May 9.1995 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,Section XI.

By signing this cenificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exammations and corrective measures described in this Owner's Repon.

Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection.

Commissions /d77/ , M/ 7b #

/ Infector's Signa:ure Nauonal Board, State, Province, and Endorsements Date u9uI E 19 W l

l i

l l