ML20095H449

From kanterella
Jump to navigation Jump to search
Unit 2 Refueling 21 ISI Summary Rept for Form NIS-1
ML20095H449
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 12/19/1995
From:
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20095H443 List:
References
NUDOCS 9512260046
Download: ML20095H449 (48)


Text

s Wisconsin Electnc Power Co.

,- 231 West Mutigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01/72 l

l l

l 1

1

UNIT 2 REFUELING 21 INSERVICE INSPECTION

SUMMARY

REPORT FOR FORM NIS-1

I. 8 /I4/~

Written by/

~ Date: /2[///9J~ ,

Reviewed by: M ate: /2-/3hf Approved byh479/ Date:/88 5 9512260046 951220 PDR ADOCK 05000301

. G. ,

. . . - - PDR_,,

Wisconsin Electric Power Co.

. 231 West Michigin Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Comrnercial service Date 10/0172 Acronvms ASME American Society of Mechanical Engineers RAYTHEON Raytheon Engineering (Formerly EBASCO Services Incorporated)

IDR Indication Disposition Report IN Information Notice ISI Inservice Inspection ISC Indication Screening Checklist LTP Long Term Plan MT Magnetic Particle Examination MWR Maintenance Work Request NDE Nondestructive Examination NRC Nuclear Regulatory Commission PBNP Point Beach Nuclear Plant P-G Phillips Getschow PT Dye Penetrant Examination PWA Professional Welding Associates QTS Quality Technical Services RRM Repair / Replacement / Modification UT U1t rasonic Examination VT Visual Examination WE - Wisconsin Electric Power Company Page 2 of 9

. . _ - ~ . . - . . _ _ _ . . .. . ..- _. . _ - . . - . . _

} 9 Wisconsin Electric Power Co.

. 231 West Michigan Avenue Milwaukee.WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-301 Conunercial service Date 10/Oln2 Table of Contents .

s

1.0 INTRODUCTION

2.0 CODE CASES AND INTERPRETATIONS 3.0 ABSTRACT OF EXAMINATIONS 3.1 Determination of Scope 3.2 Scope of Component / Weld Examinations 3.3 Completed Component / Weld Examinations 3.4 Pressure Tests 3.5 Snubber Surveillance Test 4.0 ABSTRACT OF CONDITIONS NOTED AND CORRECTIVE MEASURES TAKEN 4.1 Component / Weld 4.2 Pressure Tests l

l Page 3 of 9

, _ m - . _ _ , _ _ . _ ._ _

, ,- i I

Wisconsin Electric Power Co. l

, ,- 231 West Michigan Avenue Milwaukee, WI $3201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers. WI 54241

! Docket 50 301 Commercial Service Date 10/0102 UNIT 2 REFUELING 21 INSERVICE INSPECTION

SUMMARY

1.0 INTRODUCTION

From December 2,1994 to December 10,1995, non-destmetive examinations of selected components at PBNP Unit 2 were performed. These examinations constitute the third examination of the first period, of the third 10-year interval at PBNP Unit 2. The time interval for this examination period included the Unit 2 Refueling 21 outage (U2R21) that ran from October 7,1995 to December 3,1995.

.2.0 CODE CASES AND INTERPRETATIONS This report and examinations were completed applying the following:

2.1 ASME Code Interpretation, Section VIII-1-83-17, which allows for computer generated d.ta report forms to be used as long as size, arrangement, and content are identical.

2.2 Code Case N-460 2.3 Code Case N-448 3.0 ABSTRACT OF EXAMINATIONS 3.1 Determination of Scone Components and system areas were selected for examination in accordance with the following:

3.1.1 PBNP FSAR, Technical Specification Section 15.4.2.B 3.1.2 Long Term Inservice Examination Plan for Class 1, Class 2, and Class 3 systems at Point Beach Nuclear Plant, Third Interval, Unit 2.

3.1.3 Augmented Examination Program of Section 4 of the Inservice Inspection Long Term Plan, Third Interval 3.1.4 Requests of PBNP Personnel Page 4 of 9

s Wisconsin Electric Power Co.

. 231 West Michigan Avenue Mdwaukee, WI $320!

Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-301 Comrnercial service Date 10/01/72 3.2 Scope of domeonent/ Weld Examinations Representative samples of the following components and system areas were examined with NDE techniques by WE (QTS), RAYTHEON, Phillips Getschow (P-G) and Professional Welding Associates (PWA) personnel.

Reactor Pressure Vessel Pressurizer A Steam Generator Class 1 Pressure Retaining Valve Bolting Class 2 Piping and Supports Class 3 Pipe Supports 3.3 Completed Component / Weld Examinations HEADING DESCRIPTION Exam Type Defines the requirement or reason for the examination performed.

86E-03 Examination performed as required by ASME Section XI,1986 Edition, No Addenda B02-03 Augmented examinations performed for Reactor Coolant Pump Flywheel Integrity, per Regulatory Guide 1.14 B04-03 Augmented examinations performed on Threaded Fasteners, per IEB 82-02 P21-03 Preservice examination, per RRM 94-0083 P22-03 Preservice examination, per RRM 95-0043 P23-03 Preservice examination, per RRM 95-0013 P24-03 Preservice examination, per RRM 95-0045

. S01-03 Successive examination, per IWF-2420(b), ref. IDR 7-P-009, outage 8 - second interval Page 5 of 9 )

I

e Wisconsin Electric Power Co, l 231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-301 Commercial Service Date 10/01n2 Ind Type Description of indications.

G = geometry I = insignificant or non-relevant indications N = no indications -

R = recordable indications Results Indicates the outcome of a particular exam.

P = Pass F = Fail C = Conditionally Accepted N = No examination performed Program Indicates whether or not ASME Section XI credit has been taken for the Credit exam. Augmented or other examinations not performed for an ASME Section XI requirement will be indicated by an N.

Following are database printouts that summarize the ISI examinations that were performed during the Unit 2 Refueling 21 outage.

Examinations (See Pages 6-1 through 6-5) l l

5 i

Page 6 of 9

. . - . . . . .. ., . . - - - . . -.. . - - - . - - - - - - - . ~ ~ - - - - - - ~-x- - - - - ~ ~ ~

Wisconsin Elatric Power Company Point Beach Nuclear Plant, Unit 2 -

L 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 - Two Rivers, Wisconsin 54241 -

Docket No. 50-301 i Commercial Service Date 10/01/72 4

COMPONENT IDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM . IND COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP i 1 ITEM ISOMETRIC DIA. THICKNESS l RELIEF -. MATERIAL A & B

======================================================================================-

2H-01D VT-3 P21-03 12/12/94 95U2-754P001 P N N SPRING HANGER ,

N/A-ISI-PRI-2258 4.00 0.000 2H-01E VT-3 P21-03 12/12/94 95U'2-754P002 P N N

< SPRING HANGER i N/A ISI-PRI-2258 4.00 0.000

~ 2H-08C VT-3 P22-03 10/26/95 95U2-754P005 P N N RIGID SUPPORT N/A ISI-PRI-2248 30.00 2

2114)9A VT-3 P22-03 10/18/95 95U2-754P006 P N N RIG!D SUPPORT

, N/A ISI-PRI-2248 30.00 0.000 a

' 2H-19B - VT-3 P22-03 10/25/95 95U2-754P008 P N N l RIGID SUPPORT f

N/A ISI-PRI-2246 30.00 0.000 I

i 211-20C VT-3 P22-03 10/18/95 95U2-754P007 P N N RIGID SUPPORT N/A ISI-PRI-2246 - 30.00 0.000 i

PAGE 6-1 i I

.- . . . ~ -. ,, - ,. - -

f.

i.

l - Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 +

l 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 i- Commercial Service Date 10/01/72

COMPONENTIDENTIFICATION METHOD EXAM EXAM- EXAM DATA . RESULTS PROGRAM IND COMPONENT DESCRIPTION - TYPE DATE SHEET CREDIT TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

==========================::=======================_==================================== _

' H-44 VT-3 P23-03 10/12/95 95U2-754P003 . P N N RIGID SUPPORT N/A ISI-PRI-2325 6.00 0.000 MS-06-MSR-2001-04RI MT P24-03 10/30/95 9G-350P001 P N N PIPE TO VALVE MS-2016 C5.51 A ISI-PRI-2246 6.00 .280 CC '

PZR-MWAY-BLT-01 THRU 16 VT-1 26E-03 10/25/95 95U2-750P008 C Y I ,

MANWAY BOLTING MT B04-03 10/25/95 95U2-353P003 P N N-B7.20 ISI-PRI-2104 0.00 0.000 '

C FOUR BOLTS HAD ROUNDED INDICATIONS AS A RESULT OF IIANDLING.

PZR-RELNOZ-IRS UT 86E-03 10/24/95 95-WEP-UT-002 P Y N INSIDE RADIUS SECTION B3.120 ISI-PRI-2104 4.00 0.530 C

LIMITED EXAM BETWEEN 8:00 AND 11:00 DUE TO INSULATION SUPPORT STRAP - CODE REQUIRED COVERAGE ACHIEVED.

PZR-SAFNOZ-1-IRS UT 86E-03 10/24/95 95-WEP-UT-003 P Y N INSIDE RADIUS SECTION B3.120 ISI-PRI-2104 4.00 0.530 t C

m-PAGE 6-2

Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit 2 231 West Michigan Avenue 6610 Nuclear Road Milwaukee, Wisconsin 53201 Two Rivers. Wisconsin 54241 Docket No. 50-301 Conunercial Service Date 10/01/72

' COMPONENT IDENTIFICATION METHOD EXAM - EXAM EXAM DATA RESULTS PROGRAM IND i COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT TYP

, ITEM ISOMETRIC ' DIA. THICKNESS RELIEF MATERIAL A & B

==========================================================================

1 PZR-SAFNOZ-2-IRS UT 86E-03 10/24/95 95-WEP-UT-004 P Y N INSIDE RADIUS SECTION B3.120 ISI-PRI-2104 4.00 0.530 C

RCP-A-FLYWHEEL UT B02-03 10/21/95 95U2-150P001 P N N PUMP FLYWHEEL VT-1 B02-03 10/21/95 95U2-750P006 P N N FLYWHL ISI-PRI-2404 0.00 0.000 CC RCP-A-FLYWHEEL-BORE PT B02-03 10/20/95 95U2-450P001 P N N

, PUMP FLYWHEEL VT-1 B02-03 10/21/95 95U2-750P005 P N N BORE ISI-PRI-2404 0.00 i

l l

RCP-A-FLYWIIEEL-KEYWAY PT B02-03 10/20/95 95U2-450P002 P N N PUMP FLYWHEEL VT-1 B02-03 10/21/95 95U2-750P007 P N N KEYWAY ISI-PRI-2404 0.00 RCP-B-FLYWHEEL UT B02-03 11/01/95 95U2-150P002 P N N PUMP FLYWHEEL VT-1 B02-03 11/01/95 95U2-750P009 P N N FLYWIIL ISI-PRI-2404 0.00 0.0tB CC PAGE 6-3 ,

i I

.m . _ . - ._ _ . ... .. . . - _ _ _ _ . _ _ _ _ _ . . . _ . _ _ _ _ , _ . . ._

Wisconsin Electnc Pcwer Company Point Beach Nuclear Plant. Unit 2 .

231 West Michigan Avenue 6610 Nuclear Road .

- Milwaukee, Wisconsin 53201 Two Rivers, Wisconsin 54241 Docket No. 50-301 Commercial Service Date 10/01/72 t

i COMPONENTIDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM . IND

' COMPONENT DESCRIPTION . TYPE DATE SHEET CREDIT TYP' ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B

=================== ===== =

RCP-B-FLYWHEEL BOhtE PT B02-03 11/01/95 95U2-450P003 P N N l PUMP FLYWHEEL VT-1 B02-03 11/01/95 95U2-750P010 - P N N BORE- ISI-PRI-2404 0.00 RCP-B-FLYWHEEL-KEYWAY PT B02-03 11/01/95 95U2-450P004 P. N N i PUMP FLYWHEEL VT-1 B02-03 11/01/95 95U2-750P0ll P N N KEYWAY ISI-PRI-2404 0.00 l

l l RPV-14-683-A UT 86E-03 10/12/95 95U2-168P001 P Y N SHELL TO FLANGE (AZ. 0-180)  ;

i Bl.30 ISI-PRI-2101 132.00 0.000 '

CC l l SEE NDE PROCEDURE DEVIATION 95U2-6P001.

1 i

! SG-A-4 UT S01-03 10/16/95 95U2-163P001 C N R-TRANS CONE TO SHELL CIRCUM WELD j CI .10 - ISI-PRI-2201 0.00 0.000 f

'CC I THE INDICATIONS REPORTED WERE THE SAME AS PREVIOUSLY IDENTIFIED DURING U2R16. i l

i i ,

i l SI-842A-BLT MT B04-03 10/17/95 95U2-353P001 P N N VALVE BOLTING 10-IN DARLING CHECK VT-1 86E-03 10/17/95 95U2-750P001 P Y N' i B7.70 ISI-PRI-2126 0.00 0.000 S

l l

PAGE 6-4

-r , w . - - , . , r-

l

' Wisconsin Electric Power Company Point Beach Nuclear Plant, Unit '2 ,

231 West Michigan Avenue 6610 Nuclear Road j Milwaukee, ~#isconsin 53201 Two Rivers, Wisconsin 54241 l Docket No. 50-301 Commercial Service Date 10/Oln2

COMPONENTIDENTIFICATION METHOD EXAM EXAM EXAM DATA RESULTS PROGRAM IND l COMPONENT DESCRIPTION TYPE DATE SHEET CREDIT - TYP ITEM ISOMETRIC DIA. THICKNESS RELIEF MATERIAL A & B
=============================_============================================
' SI-842B-BLT MT BO4-03 10/17/95 95U2-353P002 P N N

' VALVE BOLTING 10-IN DARLING CHECK VT-1 86E-03 10/17/95 95U2-750P002 P- N N

, B7.70 ISI-PRI-2124 0.00 0.000 l S l SI-867A-BLT VT-1 86E-03 10/19/95 95U2-750P004 P N N

, VALVE BOLTING 10-IN DARLING CHECK MT B04 10/19/95 95U2-353P004 P N 'N

, B7.70 ISI-PRI-2126 0.00 0.000 S-SI-867A-INT VT-3 86E-03 10/19/95 95U2-754P004 P Y N

' VALVE INTERNALS 10-IN DARLING CHECK l B12.50 ISI-PRI-2126 10.00 0.000 3

i l

I PAGE 6-5 l

i I

~ . _ . . .-

a Fisconsm Elecuic Power Co.

4 231 West Michigan Avenue Milwaukee, WI $3201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial service Date 10/01/72 3.4 Pressure Tests 3.4.1 ASME Section XI Pressure Tests Following are pressure tests that have been conducted as part of the pressure test program at PBNP since the last refueling outage. >

Test

Description:

System Leakage Test of Class 1 Components Following Refueling Outage.

- System: Reactor Coolant Test Document: IT-235 Completion Date: November 30,1995 -

Test

Description:

40-Month Inservice Pressure Test of ASME Class 2 Train A High Head Safety Injection and Residual Heat Removal System: Safety Injection Test Document: IT-535A Completion Date: September 26,1995 Test

Description:

Month Inservice Pressure Test of ASME Class 2 Train A High Head Safety Injection and Residual Heat Removal System: Safety Injection Test Document: IT-535B Completion Date: September 27,1995 Test

Description:

40-Month Inservice Pressure Test of ASME Class 2 Component Cooling Water Outside Containment System: Component Cooling Water Test Document: IT-1125 Completion Date: July 11,1995 4

Test

Description:

40-Month Inservice Pressure Test of ASME Class 2 Spray Additive Tank System: Safety Injection Test Document: IT-1115 Completion Date: August 8,1995 i

4 Page 7 of 9

. . . --. ~ . - .

Wisconsin Electric Power Co.

, 231 West Michigan Avenue Milwaukee, WI $3201 Point Beach Nuclear Plant. Unit 2 4

6610 Nuclear Road i Two Rivers, W1 54241 Docket 50-301 Commercial service Date 10/01/72 3.5 Snubber Surveillance Tests 3.5.1 ASME Section XI Snubber Surveillance Tests Following are snubber inservice tests that have been conducted for snubbers less

, than 50 kips as part of the snubber surveillance test program at PBNP since the i last refueling outage.

TEST DESCRIPTION: Snubber Inservice Test for Snubbers Less than 50 kips.

Snubber: HS-22 Test Documents: MWR 9511363 Completion Date: November 4,1995 i

Results: Acceptable Snubber: IIS-23

< Test Documents: MWR 9507433

Completion Date: November 4,1995 Results: Acceptable i

Note: Section XI credit not taken, snubber will be retested later in the interval (ref.

l QCR 95-031).

a

Page 8 of 9

Wisconsin Electric Power Co.

231 West Michigan Avenue t

Milwaukee W153201 5 Point Deach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Conunercial Service Date 10/01n2 4.0 ABSTRACT OF CONDITIONS NOTED AND CORRECTIVE MEASURES TAKEN 4.1 Component / Weld 1

Nondestructive examinations were performed by QTS, RAYTHEON, and PWA personnel.

The nondestructive examinations utilized VT, PT, MT, and UT techniques. All the

- examinations were performed in accordance with written procedures that conform to the applicable sections of the ASME Boiler and Pressure Vessel Code. The following is a

summary of the recorded indications found during the examinations and evaluated by WE personnel.

IDR 95U2-7P001, Class 1 MANWAY BOLTING, PZR-MWAY-BLT-01 THRU 16 Data Sheet No. 95U2-750P008, Drawing No. ISI-PRI-2104 Indication: 4 bolts with rounded indications Disposition: Accept as is l

The rounded indications do not violate the acceptance criteria of IWB-3517. The indications

appear as chips from the handling process and are not inservice related. The worst
indication results in slightly less than a 1% reduction in cross sectional area of the bolt, therefore it is negligible. The bolting is operable, no additional or successive examinations are required.

l ISC 95U2-001, Class 2 S/G Trans Cone To Shell Circum Weld, SG-A-4 i Data Sheet No. 95U2-163P001, Drawing No. ISI-PRI-2201 )

Indicatiore: 5 subsurface volumetric indications  !

i Disposition: Accept as is l l

This examination was a successive examination in accordance with IWC-2420(b). The indications noted, were compared to the previous indications and were determined to be )

unchanged. This examination completes the requirements of successive examinations required for this component.

i l

4.2 Pressure Tests i

No reportable indications observed. _

i Page 9 of 9

I FORh! NISol OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules ,

1

1. Owner Wisconsin Electric Power Comoany. 231 W. Michigan Ave,. Milwaukee WI 53201 (Name and Address of Owner)
2. Plant Point Beach Nuclear Plant. 6610 Nuclear Road. Two Rivers. WI 54241 l (Name and Address o.' Plan 0
3. Plant Unit 2 4. Owner Certificate of Authorization (if required) Docket 50-301
5. Commercial Service Date 10/01/72 6. National Board Number for Unit N/A
7. Components inspected Component or Manufacturer or Manufacturer State or National Appurtenance Installer or Installer Province No. Board No.

Serial No.

Reactor Pressure Vessel Combustion 02741 U009973 NB 21009 Engineering Pressurizer Westinghouse 2T1 U009979 ----

A Steam Generator Westinghouse 16A-6339-1 U009974 A Class 2 Piping System Bechtel ---- - -

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the numb (r of sheets is recorded at the top of this form.

t Sheet 2 of _2__,

FORM NIS-1 CONTINUED

8. Examination Dates 10/07/95 to 12/03/95 9. Inspection laterval from 12/02/94 to 12/10/95
10. Applicable Editions of Section XI 1986 Addenda None
11. Abstract of Examinations Include a list of examinations and a statement concerning status of work required for current interval.

i Refer to attached Inservice Inspection Final Repon, Section 3.0.

j 12, Abstract of Conditions Noted.

1 Refer to attached Inservice Inspection Final Repon, Section 4.0.

13. Abstract of Corrective Measures Recommended and Taken.

. Refer to attached Inservice Inspection Final Report, Section 4.0.

We cenify that the statements made in this repon are correct and the examinations and corrective measures

, taken conform to the rules of the ASME Code,Section XI.

Cenificate of Authorization No. (if applicable) NRC Docket 50-301 Expiration Date N/A Date December 11. 19 95 Signed Wisc. Electric Power Co, By - dC Owner [

]

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel

! Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

! of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10. 1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repon in accordance with the requirements of the ASME Code,  ;

Section XI. l i By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or 4

implied, concerning the examinations and corrective measures described in this Owner's Repon.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected with this inspection.

/

b inspectdr's Sisnansre Commissions /073/. W/ 77 IO

, Nadonal Board,' State. Province, and Endorsements Date ce b /f 19 93~ l E

l l

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules i'

l Owner Wisconsin Electric Power Comoany. 231 W. Michigan Ave. Milwaukee WI 53201 (Name and Address of Owner)

2. Plant Point Beach Nuclear Plant. 6610 Nuclear Road. Two Rivers. WI 54241 (Name and Address of Plant) 3, Plant Unit 2 4. Owner Cenificate of Authorization (if required) Docket 50-301
S, Commercial Service Date 10/01/72 6. National Board Number for Unit N/A 7, Components Inspected e

i Component or Manufacturer or Manufacturer State or National 3 Appurtenance Installer or Installer Province No. Board No.

] Serial No.

Reactor Pressure Vessel Combustion 02741 U009973 NB 21009 Engineering Pressurizer Westinghouse 2T1 U009979 --

A Steam Generator Westinghouse 16A 63391 U009974 A i Class 2 Piping System Bechtel ---- - -

3 a

l

< l 4

- l NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in. x  !

11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is l numbered and the numba of sheets is recorded at the top of this form. j

Sheet 2 of 2 a

FORM NIS-1 CONTINUED

8. Examination Dates 10/07/95 to 12/03/95 9. Inspection Interval from 12/02/94 to 12/10/95
10. Applicable Editions of Section XI 1986 Addenda None
11. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

Refer to attached Inservice Inspection Final Report, Section 3.0.

12. Abstract of Conditions Noted.

Refer to attached Inservice Inspection Final Report, Section 4.0.

13. Abstract of Corrective Measures Recommended and Taken.

Refer to attached Inservice inspection Final Report, Section 4.0.

We certify that the statements made in this repon are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) NRC Docket 50-301 Expiration Date N/A Date December 11. 19 95 Signed Wisc. Electric Power Co. By b ff A._ -

owner [

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state j that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,

Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or i

implied, concerning the examinations and corrective measures described in this Owner's Report, i Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or l property <iamage or a loss of any kind arising from or connected with this inspection.

Commissions /d 71/, W/ 7f/, 2~#< M

[ Ins'pector's Signauro Nuional Boud. Sme. Province, and Endorsernents Date / e e mbrA. /1 19 95~

l l

1 4 6'se '- .r.. A s

(

l

I Wisconsin Electnc Power Co.

s 231 West Michigan Avenue Mdwaukee, WI $3201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers. WI 54241 Docket 50-301 Commercial Senice Date 10/01/72 l

UNIT 2 REFUELING 21 REPAIR / REPLACEMENT

SUMMARY

REPORT i

FOR FORM NIS-2 1

l f

Written by: / Mux o Date: /2 /[9f' Reviewed by: /14 Y[4 D Date: / //) /f5 Approved by: Date: /d- 9-II

- . . . _ . - . . ~ . . . . - - ~ _ - . - _ _ . . -. - .

Wisconsin Electric Power Co.

231 West Michigan Avenus Milwaukee, WI $3201 Point Beach Nuclear Plant, Unit 2 6610 Nuclear Road Two Rivers, WI 54241 1 Docket 50-301 i Commercial service Date 10/01n2 Acronyms i

ASME American Society of Mechanical hagineers

CR Condition Report a
MR Modification Request MT Magnetic Particle Examination
MWR Maintenance Work Request NDE Nondestructive Examination NRC Nuclear Regulatory Commission l PBNP Point Beach Nuclear Plant PT Dye Penetrant Examination RT Radiographic Examination RRM Repair / Replacement / Modification .

UT Ultrasonic Examination

. VT Visual Examination WE Wisconsin Electric Power Company i

l PAGE 2 of 6 1

Wisconsin Electric Power Co.

231 West Michigan Avenue Milwaukee, WI $3201 Point Beach Nuclear Plant, Urut 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Commercial Service Date 10/01/72 Table of Contents

1.0 INTRODUCTION

2.0 CODE CASES AND INTERPRETATIONS 3.0 ABSTRACT OF REPAIR / REPLACEMENT PAGE 3 of 6

g _ _ __ _ _ _ _ _ __ -. .. _ . _ _ - _ _ _ _ _ _ _ _ _ _ __ _ _. . . - _ __ . . _

i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS i As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date November 30.1995 l Name 231 W. Michiran Ave. Milwaukee WI 53201 Sheet 1 of 2 Address 4
2. Plant Point Beach Nuclear Plant Unit 2 Name 6610 Ntricar Road. Two Rivers. WI 54241 MWR 9501574 PO 247390

,' Address Repair Organization P.O. No., Job No., etc.

3. Work Prefortned By Crane Valves Type Code Symbol Stamp VR / NR Name Authorization No. 576 / 63 720 N.' Parkwood Dr. Romeoville. IL 60441 Expiration Date 07-02-96 / 02-17-97 Address l - 4. Identification of System Reactor Coolant

, 5. (a) Applicable Construction Code ASME Section III 19.15, Edition, Winter 1966 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19.86. no addenda

. 6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

RC-00435 Crosby H 51249 N/A N/A 1%5 Repaired Yes 4

=

7. Description of Work Replaced disc insert. bellows, and disc holder assembly and no7zle
8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O Other a Pressure usi Test Temp. 'F
Functional

) NOTE: Supplemental sheets in form of !!sts, sketches, or drawings may be used, provided (1) size is 8% in.

j x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

j w

- - - ~ - . - -_ _ - . - . = - - . . --. -- - . - - . .

l

  • I l

.. t 1

. I 4

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 94-0065 This valve was reoaired and placed in stock as a soare Applicable Manufacturer's Data Reports to be attached 1

4 l

1 __

CERTIFICATE OF COSIPLIANCE We certify that the statements made in the report are correct and this Repair conforms to the rules of the ASME Code,Section XI, repair or replacement i

Type Code Symbol Stamp VR/NR Certificate of Authorization No. Docket 50-301 Expiration Date N/A i

Signed $s,~ f? WJAo A I*r % .d,~sru Date Dece-}ee f , t9 'lf

/ Owner or Owner's Designee, Tide f

i.

CERTIFICATE OF INSERVICE INSPECTION i I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel j Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and behef, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

i By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /077/ W/ 8 , 1 llispector's Signamre Naticual Board', State Province, and Endorsements Date ec e d et. 7 1997 I 1

- - . _ _ . . _ . _ _ _ .__ _. _ _ _ _ _ _ _O

l Wisconsin Electnc Power Co.

231 West Michigan Avenue Milwaukee, WI 53201 Point Beach Nuclear Plant. Unit 2 6610 Nuclear Road Two Rivers, WI 54241 Docket 50-301 Cornmercial service Date 10/01/72 l

UNIT 2 REFUELING 20 B_EPAIR/ REPLACEMENT

SUMMARY

1.0 INTRODUCTION

From December 2,1994 to December 10,1995, repairs and replacements were performed on items at PBNP Unit 2 . These repairs and replacements were completed in the third examination of the first period, of the third 10-year interval at PBNP Unit 2. The time interval for this examination period included the Unit 2 Refueling 21 outage (U2R21) titat ran from October 7,1995 to December 3,1995.

2.0 CODE CASES AND INTERPRETATIONS This report utilized the following Code Cases and Interpretations:

2.1 ASME Code Interpretation, Section VIII-1-83-17, which allows for computer generated data report forms to be used in place of Code forms as long as size, arrangement, and content are identical.

3.0 ABSTRACT OF REPAIR / REPLACEMENT 3.1 Repairs / replacements performed on ASME Class 1 and 2 items are documented on the attached NIS-2 forms. Repairs / replacements on ASME Class 3 items are documented on NIS-2 forms and maintained on file at PBNP. They are not included in this report in accordance with ASME Section XI, IWA-6210(c).

RRM 94-0065, MWR 9501574 COMPONENT: RC-00435, Pressurizer Safety Valve CLASS: 1 DESCRIPTION: Replaced disc insert, bellows, disc holder assembly and nozzle at a vendors offsite facility. After repairs the valve was placed in stock as a spare.

RRM 94-0079, MWR 9410717 COMPONENT: PS SI 301R-2H16, Pipe Support CLASS: 2 DESCRIPTION: Replaced support as a result of IEB 79-14.

RRM 94-0079, MWR 9410713 COMPONENT: PS SI 301R-2H17, Pipe Support CLASS: 2 DESCRIPTION: Reinforced and shinuned support as a result of IEB 79-14. )

l PAGE 4 of 6

Wisconsin Electric Power Co.

231 West Michigan Avenue

l. Milwaukee.WI 53201 Point Beach Nuclear Plant, Unit 2 l 6610 Nuclear Road Tv 3 Rivers. WI 54241 Docket 50 301 Commercial service Date 10/01r/2 RRM 94-0079, MWR 9410704 COMPONENT: PS SI 301R-2H20, Pipe Support CLASS: 2 DESCRIPTION: Reinforced support as a result of IEB 79-14.

RRM 94-0083, MWR 9410702 and 9410703 COMPONENT: PS SI 1501R-2-2H1 and PS SI 1501R-3-2H1, Spring Hangers CLASS: 2 4 DESCRIPTION: Swap spring hangers.

During a previous maintenance activity requiring the removal of both spring hangers, the hangers were incorrectly reinstalled in the opposite locations.

RRM 95-0001, MWR 9403483 COMPONENT: P-002C, Charging Pump CLASS: 2 DESCRIPTION: Replaced cage and seat.

Disassembly of the pump was required due to odd noises and low capacity, this revealed porosity in the cage and seat.

i RRM 95-0035, MWR 9504026 and 9504031 COMPONENT: SI-00854A and SI-008548, RHR Pump Suction Header Check Valves CLASS: 2 DESCRIPTION: Replaced soft seat and disk assembly with metallic hardseat and disk.

. RRM 95-0040, MWR 9503511 COMPONENT: P-002C, Charging Pump CLASS: 2 DESCRIPTION: Replaced discharge valve cages.

RRM 95-0043, MWR 9508131 and 9508132 COMPONENT: PS EU-01-2H20A and PS EB-01-2H9A, Pipe Supports CLASS: 2 DESCRIPTION: Stiffened supports as a result of IEB 79-14.

RRM 95-0043, MWR 9508289 COMPONENT: PS EB-01-2H8A, Pipe Support CLASS: 2 DESCRIPTION: Added this support as a result of IEB 79-14.

PAGE 5 of 6

Wisconsin Electric Pocer Co.

231 West Mishigan Avenue l Milwaukee, W1 S3201 l

Point Beach Nuclear Plant. Unit 2 j 6610 Nuclear Road )

Two Rivers, WI 54241 l Docket 50-301 Commercial service Date 10/0102 RRM 95-0043, MWR 9508133 COMPONENT: PS EB-01-2H19, Pipe Support CLASS: 2 DESCRIPTION: Replaced a spring hanger with a rigid support as a result of IEB 79-14.

RRM 95-0044, MWR 9508364 COMPONENT: PS AC 152N-4-2AC12, Pipe Support CLASS: 2 DESCRIPTION: Increased weld size on support as a result of IEB 79-14,

! RRM 95-0044, MWR 9508362 COMPONENT: PS AC 152N-4-2R143, Pipe Support CLASS: 2 DESCRIPTION: Removed support as a result of IEB 79-14.

RRM 95-0047, MWR 9507442 COMPONENT: PS AC 2503N-1-2SBH11, Pipe Support CLASS: 2 DESCRIPTION: Install a new pipe support.

RRM 95-0049 and 95-0055, MWR 9409992 i COMPONENT: MS-00265 and Piping EB-7, Steam Generator Blowdown Isolation Valve CLASS: 2 DESCRIPTION: Replace valve and repair piping.

RRM 95-0053 and 95-0054, MWR 9502229 COMPONENT: MS-2020, Aux. Peed Pump Steam Supply MOV CLASS: 2

, DESCRIPTION: Replaced body to bonnet nuts and studs l RRM 95-0058, MWR 9508285 and 9508294 COMPONENT: HX-001A/B, Steam Generators CIASS: 1 DESCRIPTION: Install an additional hardroll in the tubesheet to create a new pressure boundary.

RRM 95-0059, MWR 9505335

. COMPONENT: CV-00203, Letdown Orifice Outlet Relief Valve  ;

CLASS: 2 DESCRIPTION: Replaced valve with one from stock, to test the valve at the vendors facility.

i i l PAGE 6 of 6

i FOlut NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI a

1. Owner Wisconsin Electric Power Comoany Date February 23.1995 d

Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet I of 2 Address 2, Plant Point Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MR 94-037. MWR 9410717. 9410713. 9410704 Address Repair Organization P.O. No., Job No.. etc.

f

~

3. Work Preformed By Phillios-Getsshow Type Code Symbol Stamp N/A
Name Authorization No. N/A 2860 Glenmore Road. Green Bay. WI 54311 Expiration Date N/A l Address
4. Identification of System Containment Sorav l S. (a) Applicable Construction Code AISC 6th Edition 19 N/A Edition, N/A Addenda, None Code Case 4

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986. no addenda

6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME l

National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

PS St 30lR 2H16 N/A N/A N/A N/A N/A Replacement No PS SI 30lR 2H17 N/A N/A N/A N/A N/A Replacement No
PS St 30lR 2H2O N/A N/A N/A N/A N/A Replacement No i
7. Description of Work Modify supports in accordance with MR 94437 (support uourade for IEB 7944 program) l l
8. Tests Conducted: Hydrostatic O Pneumatic 0 Nominal Operating Pressure O

! Other a Pressure osi Test Temp. *F Visual NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is munbered and the number of sheets is recorded at the top of this form.

a

___.a _ - - - - - - _ - - . - - - , - _ - _ - - - . _ _ _ . - - - - - - - - - - - - - - - - - - . - - _ - - - - - _ _ - _ - - . - - - . _ _ - - - - _ _ - -

O Sheet 2 of 2 Form NIS-2 Continued

9. Remarks 94-0079 Applicable Manufacturer's Data Repons to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed < Y$ $ u n o TSI Ccw h 4' Date /Jecen be< 5 ,19 W

/ Owner or Owner's Des'ignee. Tide CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co, of flartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

0 h Commissions /0 72f, WZ7sr .T, M R

[ tn/pector's' Signature National Board, State Province, and Endorsements Date bb 19 Y

l'OR51 NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACESIENTS As Required by the Provisions of the ASSIE Code Section XI

1. Owner Wisconsin Electric Power Company Date February 15.1995 Name 231 W. Michlean Ave. Milwaukee WI 5320L Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9410702. 9410703 Address Repair Organization P.O. No.. Job No. etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Safety Iniection
5. (a) Applicable Construction Code AISC 6th Ed. 19 N/A Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Narne of Manufacturer Board Other Year or Stamped Component Manufacturer Setial No. No. Idennfication Duitt Replacement (Yes or No)

PS SI 150!R 3-2111 N/A N/A N/A 2}I4tD N/A Replacement No PS S! 1501R 2 2111 N/A N/A N/A 2114tE N/A Replacement No

7. Description of Work Swao sorine cans.
8. Tests Conducted: Ilydrostatic O Pneumatic O Nominal Operating Pressure O Other a Pressure osi Test Temp. *F 4 VT-3 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I l

l Sheet 2 of 2 i

Form NIS-2 Continued

i. i
9. Remarks RRM 94-0083. also datasheets 95U2-754P001 and 95U2-754P002 Applicable Manufacturer's Data Reports to be attached 4

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed- 18 [2.4a I4 T Co<vd.$ /- Date Bece-e / u # .19 Y

  1. Owner or Owner's Designee, Tide I

a CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

of Hartford. CT have inspected the components described in this Owner's Report buring the period December 2.1994 to December 10.1995 . and state l

that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. l By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. ,

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or l property damage or a loss of a y kind arising from or connected with this inspection.  !

d tolpector'sIignature Commissions /073 / W/ W National Board, State Provine'e, and Endorsements

/'

Date n ubm b 19 T 1

+

ww ., - - - - , , - - - - . - - - - - . _ . - - - . - - _ _ - - - _ _ _ - - _ _ _ _ . -

.- - . . - . = _ _ . . ._. --.._-. .- - . . - - .- -.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l As Required by the Provisions of the ASME Code Section XI l

1. Owner Wisconsin Electric Power Company Date December 29.1994 Name 231 W. Michiran Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 2  ;

Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9403483 Address Repair Orgamzation P.O. No., Job No., etc.

3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical Volume and Control West E-Spec 676370
5. (a) Applicable Construction Code B31 1 19 67 Edition, N/A Addenda, N/A Code Case ]

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda

6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Nanu of Manufacturer Board Other Year or Stamped Name of Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

Ajax N/A N/A N/A N/A Replacement No P-002C

7. Description of Work Reolaced care and seat
8. Tests Conducted: Hydrostatic O Pneumatic 0 Nominal Operating Pressure O Other a Pressure esi Test Temp. *F IT Flowrate and vibration NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) Information in items 1 thtough 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of_2._

Form NIS-2 Continued

9. Remarks RRM 95-0001 Applicable Manufacturer's Data Reports to be attached l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed Im N 7In ~

IJT Cou/wd Date Awam /e # 19 '7f'

  1. Owner or Owner's Designee. Tide CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of flattford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed exarninations and taken corrective l measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

b Commissions /073/ , W/77. IM ins (ector's Signature National Board, State, Province, and Endorsements Date c Iv 7 19fI

FOR51 NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACE 51ENTS As Required by the Provisions of the ASSIE Code Section XI

1. Owner Wisconsin Electric Power Company Date May 3.1995 and May 9.1995 Name 231 W. Michinan Ave. Milwaukee WI 53201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI $4241 MWR 9504026. 9504031 Address Repair Organization P.O. No., Job No., etc.
3. Work Prefonned By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System .Jafety Iniection i

l 5. (a) Applicable Construction Code B16.3419 88 Ec'ition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda

6. Identification of Components Repaired or Replaced and Replacement Components l

l l

Repaired, ASME l National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped

! Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

SI@834A Aloyco N/A N/A N/A N/A Replacement No Si @ 854B Aloyco N/A N/A N/A N/A Replacement No 1

l

7. Description of Work Replaced valve disk and seat
8. Tests Coaducted: Ilydrostatic O Pneumatic O Nominal Operating Pressure O Other a PressureJ6Lpsi Test Temp. *F PressureJbipsi Leak Test NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95 0035. CR 95-613 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Ret >lacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A j Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed l ,o o TS T Can dab Date Oceea be*r f ,19 W

[ Owner or Owner's Designee. Tide CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel l Inspectors and the State or Province of Wisconsin and employed by HSBil. Co.

l of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective sneasures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or iraplied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /D 73 / , hil 7 fs' i bO

/' inspector's Signature National Board, State, Province, and Endorsements Date c.c 51- 7 19 95 '

1 o

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisic s of the ASME Code Section XI 1 Owner Wisconsin Electric Power Company Date July 7.1995 4 Name 231 W. Michigan Ave. Milwaukee WI $3201 Sheet 1 of 2 Address

2. Plant Point Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9503511 Address Repair Organization P.O. No.. Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stanp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Chemical Volume and Control Westinghouse E-Spec 676370
5. (a) Applicable Construction Code B31.119 67 . Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components i

Repaired. ASME National Replaced, Code Name of Name of Manuf?cturer Board Other Year or Stamped Compone. Manufacturer Serial No. No. Identification Built Replacement (Yes or No) 4 P4X)2C Ajax N/A N/A N/A N/A Replacement No

7. Description of Work Reolaced discharge valve caces
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other a Pressure esi Test Temp. 'F IT-22 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this rep it is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

s Sheet 2 of 2 l l

Form NIS-2 Continued

9. Remarks RRM 954040 Apphcable Manufacturer's Data Reports to be attached l

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Cenificate of Authorization No. Docket 50-301 Expiration Date N/A Signed b _ .?$ $w a C$ r (m.-dw.t r.M Date A. rw be v' C* , 19 'N '

/ Owner or Owner's Designee, THe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co. ._

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /07Il i K 7f , Ide A

[ lospector's Fignature National Board, State, Province, and Endorsements Date e.c A7 1995~

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date November 29.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet I of 2 Address
2. Plant Point Beach Nuclear P' ant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9508131. 9508132. 9508133. 9508289 Address Repair Organization P.O. No.. Job No.. etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Main Steam Bechtel M-78, AISC 6th Ed. MS-SP58,1967
5. (a) Applicable Construction Code B31.1 19 67 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Jection XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced. Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

PS EB.01-21120A N/A N/A N/A N/A N/A Repair No PS EB-01-2119A N/A N/A N/A N/A N/A Repair No PS EB-012118A N/A N/A N/A N/A N/A Replacement No PS EB4)l-2H19 N/A N/A N/A N/A N/A Replacement No i

7. Description cf Work 2H20A and 2H9A - stiffen support. 2H8A - add new support.

2H19 - replace sorine hancer with ricid succort

8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O Other a Pressure osi Test Temp. *F VT-3 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the nutnber of sheets is recorded at the top of this form.

Sheet 2 of 2 l l

Form NIS-2 Continued l 1

9. Remarks RRM 95-0043. see datasheets 95U2-754P005. 95U2-754P006. 95U2-754P007. and 95U2-754P008 Applicable Manm*acturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement / Repair conforms to the rules of the ASME Code,Section XI. repair or replacernent Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed 2I b~ _ DE ccw/~ A Date Credu 4 , 19 Y

/ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors ad the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state  ;

that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective l measures described in this Owner's Report in accordance with the requirements of the ASME Code, )

Section XI.

By signing this certificate ricither the Inspector nor his employer makes any warranty, expressed or 1

implied, conceming the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

I Commissions /073/ i N/' 7b' ddO 8

/ / Inspector's Signature National Board. State Province, and Endorsements Date da7 19 7 ,

l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI  !

l

1. Owner Wisconsin Electric Power Comoany Date November 29.1995 Name 231 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 1 Address
2. Plant Point Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9508362. 9508364 Address Repair Organization P.O. No., Job No.. etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A j Address 4
4. Identification of System Component Cooline Water
Westinghouse E-Spec 6-676262, AISC 6th Ed. MSS-SP58
5. (a) Applicable Construction Code B31.1 19 67 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired. ASME National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

PS AC 152N42Act2 N/A N/A N/A N/A N/A Repaired No

, PS AC 152N42Rt43 N/A N/A N/A N/A N/A Replacement No f

j 7. Description of Work 2ACl2 increase weld size. 2R143 remove support

8. Tests Conducted: Hydrostatic O Pneumatic 0 Nominal Operating Pressure O Other a Pressure osi Test Temp. *F

, Visual NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i e

9

s  :

i l Sheet 2 of 2 l l

Form NIS-2 Continued I

9. Remarks RRM 95-0044 )

Applicable Manufacturer's Data Reports to be attached l

)

1 i

CERTIFICATE OF COMPLIANCE

?

We certify that the statements made in the report are correct and this Replacement / Repair conforms to the rules of the ASME Code,Section XI. repair or replacement 4

a Type Code Symbol Stamp N/A J,

Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signedbm b ku 2* SE Ge,< k h- Date Dn. . < Au & 19 W

[ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel laspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components dese,ibed in this Owner's Report during the period 13ecember 2.1994 to December 10.1995 . and state ,

that to the best of my knowledge and belief, the Owner has performed examinations and taken co:rective l measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

1 i

By signing this certificate neither the Inspector not his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repon.  ;

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or  ;

property damage or a loss of any kind arising from or connected with this inspection.

Commissions /b7 P/ , W' 7P, EAIN l

[ Inipector'stignature National Board, State, Province, and Endorsements l

Date cedeca. 7 19 C l

' FARM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Electric Power Company Date November 15.1995 Name 231 W. Michiean Ave. Milwaukee WI 53201 Sheet I of 2 Address
2. Plant Egint Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9507442 Address Repair Organization P.O. No., Job No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authonzation No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Component Cooline Water
5. (a) Applicable Construction Code B)l.1 19 92 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacement (Yes or No)

PS AC 2503N 12SBlill N/A N/A N/A N/A 1995 Replaced No l

7. Description of Work Install new oine support
8. Tests Conducted
liydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other e Pressure psi Test Temp. 'F Visual 1

~

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % in.

x 11 in., (2) information in items 1 through 6 on this report la included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

i i

Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95-0047. see Condition Report CR 95-564 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reolacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed i ~ /$ Y5n - If? wm m .. Date Ow.,k 7 19 97
  1. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boilcr and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,

'Section XI, By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /07]l r IVf W > Si

[ dnspector's Signature National Board. State, Province, and Endorsements Date cem it l 19 Y

+

l

, FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1

1. Owner Wisconsin Electric Power Comoany Date November 3.1995 j Name , '

131 W. Michigan Ave. Milwaukee WI 53201 Sheet 1 of 2 l Address I I

a 2. Plant Point Beach Nuclear Plant Unit 2 )

, Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9409992 Address Repair Organization P.O. No.. Job No. etc.

3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. W1 54241 Expiration Date N/A Address a
4. Identification of System Main Steam
5. (a) Applicable Construction Code 19 Edition, N/A Addenda, N/A Code Case B16.5,1967 Ed., Bechtel Spec 6118 M-83 B31.1,1967 Ed., Bechtel Spec 6118-M-3320 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components i

I i Repaired, ASME l National Replaced, Code

Name of Name of Manufacturet Board Other Year or Stamped 4

Component Manufacturer Serial No. No. Idenufication Built Replacement (Yes j or No)

MS@265 Vogt N/A N/A N/A N/A Replaced No Piping EB.7 Bechtel N/A N/A N/A N/A Repair No 1

i

7. Description of Work Replaced valve and repair einine ,

1

8. Tests Conducted: Hydrostatic a Pneumatic O Nominal Operating Pressure O Other O Pressure 1356 psi Test Temp. 39 'F 1

l NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) stze is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. l l

,a ,

i .Ns l Sheet 2 of 2 i'

Fonn NIS-2 Continued

. 9. ' Remarks RRM 95-0049. RRM 95-0055 l Ap4icable Manufacturer's Data Reports to be attached I

i i

i i

.i CERTIFICATE OF COMPLIANCE 4

We certify that the statements made in the report are correct and this Replacement / Repair conforms to the rules of the ASME Code,Section XI. repair or replacernent I

Type Code Symbol Stamp N/A i

j Certificate of Authorization No. Docket 50-301 Expiration Date N/A i

Signed db & ISI Gew-c/wt Date de m ,v a r ( , 19 9f

/ Owner or Owner's Designee. Title i

i CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commisse issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBIL Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measces described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

b / Inspector /s Signature Commissions &72/ Iv/79 . 4 /b N National Board. State. Province. and Endorsements Date lheculus 7 19 GT

1 I

. l O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l

1, Owner Wisconsin Electric Power Company Date December 4.1995 l Name 231 W. Michlean Ave. Milwaukee WI 53201 Sheet I of 2 Address

2. Plant Point Beach Nuclear Plant Unit 2 Narne 6610 Nuclear Road. Two Rivers. WI $4241 MWR 9502229 Address Repair Organization P.O. No.. Job No.. etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol Stamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI 54241 Expiration Date N/A Address
4. Identification of System Main Steam
5. (a) Applicable Construction Code 19 Edition, N/A Addenda, N/A Code Case ASTM A-194 Class 2H-1967 Ed. Bechtel Spec P-6118-M91-017-2 ASTM A-193 Grade B71967 Ed. Bechtel Spec P-6119-M91-017-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda i
6. Identification of Components Repaired or Replaced and Replacement Components 1

Repaired. ASME

, National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Identification Built Replacenwne (Yes

, or No)

MS-2020 Powell 57645 N/A N/A N/A Replacement No f

i l

?

7. Description of Work Replaced body to bonnet nuts and studs i
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other a Pressure osi Test Temp. _*F IT-9A l NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

l x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is

, numbered and the number of sheets is recorded at the top of this form.

t

i

  • l l

1 Sheet 2 of 2 I Form NIS-2 Continued

9. Remarks RRM 95-0053. RRM 95-0054 Applicable Manufacturer's Data Repons to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed I b bh i_s i c eivb u.* tw Date Oven }w 8 ,19 Y

[ Owner or Owner's Designee. Title I

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin _ and employed by HSBII. Co. ,

of Hartford. CT have inspected the components described in this  !

Owner's Report during the period December 2.1994 to December 10. 1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a 1 ss of y kind arising from or connected with this inspection.

/ '

Commissions /473/ 1 k/' 7ff's Ind' -

[ Inhetor's Signature National Board. State. Province. and Endorsements Date deu A P 19 9F l l

\

'e i

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

- 1. Owner Wisconsin Electric Power Comoany Date November 12. 1995 Name 2 231 W. Michigan Ave. Milwaukee W1 53201 Sheet I of 2 4 Address I 2. Plant Point Beach Nuclear Plant Unit 2

Name

! 6610 Nuclear Road. Two Rivers. WI $4241 MWR 9508285. 9508294 Address Repait Organization P.O. No., Job No., etc.

J l 3. Work Preformed By BWNT Type Code Symbol Stamp N/A l Name Authorization No. N/A 155 Millridge Rd. Lynchburg. VA 24502 Expiration Date N/A Address

4. Identification of System Reactor Coolant

)

5. (a) Applicable Construction Code ASME Section III 19_6_5, Edition, N/A Addenda, N/A Code Case
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda i
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced. Code i Other Year or Stamped Name of Name of Manufacturer Board Component Manufacturer Serial No. No. Identificanon Built Replacement (Yes or No)

!!X @ lA Westinghouse 16A4339-1 A S/G A 1967 Repair Yes I!X@lB Westinghouse 16A-6339 2 B S/0 B 1967 Repair Yes l

t j 7. Description of Work Install an additional hardroll in the tubesheet

8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O Other a Pressure osi Test Temp. *F Eddy Current i

~

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.

x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

4 1

1

0 l

,. l Sheet 2 of 2 Form NIS-2 Continued .

1 1 9. Remarks RRM 95-0058  !

l Applicable Manufacturer's Data Reports to be attached i

i CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this Repair conforms to the rules of the ASME Code,Section XI. repair or replacement i

5 Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A Signed Y 7$ 3 - 13T coerdo.non Date Okedw f 19 95

[ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the ut.dersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSB11. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

hd I / nspector's Signature Commissions /0 73 f , L417 Vu I. Al A

/"'

National Board, State, Province, and Endorsements Date Neu 7 19 45^

= - - --- - - . - - - - - - - - - - - - - - - - - _ _ . . . - . _ _ . - . _ _ _ . - - - - - . - . -

,4 e

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI ,

1. Owner Wisconsin Electric Power Comoany Date December 2.1995 Name 231 W. Michigan Ave. ' Milwaukee WI $3201 Sheet 1 of 2 Address
2. Plant Point Beach Nuclear Plant Unit 2 Name 6610 Nuclear Road. Two Rivers. WI 54241 MWR 9505335 Address Repair Organization P.O. No., fob No., etc.
3. Work Preformed By Wisconsin Electric Power Co. Type Code Symbol 5 tamp N/A Name Authorization No. N/A 6610 Nuclear Road. Two Rivers. WI $4241 Expiration Date N/A Address
4. Identification of System Chemical Volume and Control
5. (a) Applicable Construction Code ASME Section VIII 19_6_5 Edition, N/A Addenda, N/A Code Case West E-Spec 676257 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86. no addenda
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Replaced, Code Name of Name of Manufacturer Board Other Year or Stamped Component Manufacturer Serial No. No. Idennficanon Built Replacement (Yes or No)

CV-00203 Crosby N/A N/A N/A N/A Replaced Yes I

7. Description of Work Replace valve with one from stock
8. Tests Conducted: Ilydrostatic 0 Pneumatic 0 Nominal Operating Pressure O i Other e Pressure osi Test Temp. *F l IT-235 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. l x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l

,d '

o Sheet 2 of 2 Form NIS-2 Continued

9. Remarks RRM 95-0059. see Condition Report CR 95-620 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacernent Type Code Symbol Stamp N/A Certificate of Authorization No. Docket 50-301 Expiration Date N/A

//

Signed ( 2b & ISE CocMow'Mol Date Ofchsan 8 19 W

[ Owner or Owner's Designee. Tide CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII. Co.

of Hartford. CT have inspected the components described in this Owner's Report during the period December 2.1994 to December 10.1995 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or  :

property damage or a loss of any kind arising from or connected with this inspection. J

/ Commissions /07.?/. W' 7f, MMO

[ Inpfector's 5fgnature National Boar'd, State, Province, and Endorsernents l Date ce d r2 k 19 M I l

.