Category:Inspection Report
MONTHYEARIR 05000219/20240022024-09-0505 September 2024 – NRC Inspection Report 05000219/2024002 and 07200015/2024001 IR 05000219/20240012024-05-14014 May 2024 Decommissioning Intl, LLC Oyster Creek Nuclear Generating Station - NRC Inspection Report No. 05000219/2024001 ML24046A1242024-02-29029 February 2024 – NRC Inspection Report 05000219/2023003 IR 05000219/20230022023-11-0909 November 2023 EA-23-076 Oyster Creek Nuclear Generating Station - Notice of Violation and Proposed Imposition of Civil Penalty - $43,750 - NRC Inspection Report No. 05000219/2023002 ML23214A2472023-08-22022 August 2023 NRC Inspection Report 05000219/2023002 IR 05000219/20230012023-05-31031 May 2023 NRC Inspection Report No. 05000219/2023001 IR 07200015/20234012023-05-16016 May 2023 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2023401 IR 05000219/20220022023-02-0909 February 2023 NRC Inspection Report No. 05000219/2022002 IR 07200015/20224012022-12-0606 December 2022 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2022401 (Letter & Enclosure 1) IR 05000219/20220012022-08-11011 August 2022 NRC Inspection Report 05000219/2022001 IR 05000219/20214022022-01-26026 January 2022 EA-21-041: Confirmatory Order Related to Oyster Greek Nuclear Generating Station - NRC Investigation Report I-2020-007; NRC Inspection Report Nos. 05000219/2021402 & 07200015/2021401 IR 05000219/20214032021-12-21021 December 2021 EA-21-093 Notice of Violation and Proposed Imposition of Civil Penalty - $150,000, Inspection Report No. 05000219/2021403 IR 05000219/20210032021-11-16016 November 2021 NRC Inspection Report No. 05000219/2021003 IR 05000219/20214042021-08-26026 August 2021 NRC Independent Spent Fuel Storage Security Inspection Report No. 07200015/2021402 and Security Decommissioning Inspection Report 05000219/2021404 - (Public) ML21202A2312021-07-28028 July 2021 Discretionary Security Decommissioning Inspection Report No. 05000219/2021403 - Public Version IR 05000219/20210022021-07-27027 July 2021 NRC Inspection Report No. 05000219/2021002 and Independent Spent Fuel Storage Installation Report 07200015/2021002 IR 05000219/20210012021-05-18018 May 2021 NRC Inspection Report No. 05000219/2021001 and Independent Spent Fuel Storage Installation Report 07200015/2021001, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station IR 05000219/20204022020-12-14014 December 2020 Security Decommissioning Inspection Report 05000219/2020402 (Public - No Findings) IR 05000219/20200032020-10-21021 October 2020 NRC Inspection Report No. 05000219/2020003, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20204012020-07-27027 July 2020 Security Baseline Inspection Report 05000219/2020401 IR 05000219/20200022020-07-20020 July 2020 NRC Inspection Report No. 05000219/2020002, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20200012020-04-20020 April 2020 Forked River, New Jersey, NRC Inspection Report 05000219/2020001 IR 05000219/20190042020-01-0606 January 2020 NRC Inspection Report 05000219/2019004, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20190032019-10-28028 October 2019 NRC Inspection Report No. 05000219/2019003, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20190022019-07-24024 July 2019 NRC Inspection Report 05000219/2019002 IR 05000219/20190012019-04-15015 April 2019 NRC Inspection Report No. 05000219/2019001, Oyster Creek Nuclear Generating Station IR 05000219/20194012019-03-25025 March 2019 NRC Inspection Report No. 05000219/2019401 (Public) IR 05000219/20180122019-02-19019 February 2019 NRC Inspection Report No. 05000219/2018012, Oyster Creek Nuclear Generating Station IR 05000219/20180032018-11-0808 November 2018 Integrated Inspection Report 05000219/2018003 IR 05000219/20180022018-08-0202 August 2018 Integrated Inspection Report 05000219/2018002 and Independent Spent Fuel Storage Installation Report 0700015/2018001 IR 05000219/20184102018-06-18018 June 2018 Security Inspection Report 05000219-2018410 (Cover Letter) IR 05000219/20180012018-05-0808 May 2018 Integrated Inspection Report 05000219-2018001 and Exercise of Enforcement Discretion IR 05000219/20180102018-02-28028 February 2018 Design Bases Assurance Inspection (Programs) Report 05000219/2018010 IR 05000219/20170062018-02-28028 February 2018 Annual Assessment Letter for Oyster Creek Nuclear Generating Station (Reports 05000219/2017006 05000219/2017402 and 05000219/2017501) IR 05000219/20170042018-01-24024 January 2018 NRC Integrated Inspection Report 05000219/2017004 IR 05000219/20170092017-11-30030 November 2017 Temporary Instruction 2515-191 Inspection Report 05000219/2017009 IR 05000219/20174052017-10-25025 October 2017 Problem Identification and Resolution Sample Security Inspection Report 05000219/2017405 (Cover Letter) IR 05000219/20170032017-10-17017 October 2017 Integrated Inspection Report 05000219/2017003 IR 05000219/20170082017-10-17017 October 2017 Supplemental Inspection Report 05000219/2017008 and Assessment Follow-Up Letter IR 05000219/20175022017-10-16016 October 2017 Evaluated Emergency Preparedness Exercise Inspection Report 05000219-2017502 IR 05000219/20170052017-08-28028 August 2017 Updated Inspection Plan Report 05000219 2017005 with Report 22 IR 05000219/20174042017-08-15015 August 2017 Problem Identification and Resolution Cyber Security Inspection Report 05000219/2017404 (Cover Letter) IR 05000219/20170022017-08-0303 August 2017 Integrated Inspection Report 05000219/2017002 IR 05000219/20174032017-05-0909 May 2017 Security Inspection Report 05000219-2017403 (Cover Letter) IR 05000219/20170012017-05-0808 May 2017 Integrated Inspection Report 05000219/2017001 IR 05000219/20170072017-05-0101 May 2017 IR 05000219/20160042017-04-13013 April 2017 Final Significance Determination for a White Finding with Assessment Follow-up and Notice of Violation - Inspection Report 05000219/2016004 IR 05000219/20160062017-03-0101 March 2017 Annual Assessment Letter for Oyster Creek Nuclear Generating Station (Report 05000219/2016006) with Report 22 IR 05000219/20164042016-12-22022 December 2016 Material Control and Accounting Program Inspection Report 05000219/2016404 IR 05000219/20160082016-12-14014 December 2016 Problem Identification and Resolution Inspection Report 05000219/2016008 2024-09-05
[Table view] Category:Letter
MONTHYEARML24274A0822024-09-25025 September 2024 Independent Spent Fuel Storage Installation Security Plan, Training Qualification Plan, Safeguards Contingency Plan, Revisions 1 and 2 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status IR 05000219/20240022024-09-0505 September 2024 – NRC Inspection Report 05000219/2024002 and 07200015/2024001 PNP 2024-030, Update Report for Holtec Decommissioning International Fleet Decommissioning Quality Assurance Program Rev. 3 and Palisades Transitioning Quality Assurance Plan, Rev 02024-08-0202 August 2024 Update Report for Holtec Decommissioning International Fleet Decommissioning Quality Assurance Program Rev. 3 and Palisades Transitioning Quality Assurance Plan, Rev 0 ML24214A0372024-08-0101 August 2024 License Amendment Request to Revise Renewed Facility Operating License to Add License Condition 2.C.(18) to Include License Termination Plan Requirements ML24179A1842024-07-23023 July 2024 June 20, 2024, Clarification Call on Preapplication Readiness Assessment of the Holtec Decommissioning International License Termination Plan ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities IR 05000219/20240012024-05-14014 May 2024 Decommissioning Intl, LLC Oyster Creek Nuclear Generating Station - NRC Inspection Report No. 05000219/2024001 ML24120A0412024-04-29029 April 2024 Annual Radioactive Environmental Operating Report for 2023 L-24-009, HDI Annual Occupational Radiation Exposure Data Reports - 20232024-04-29029 April 2024 HDI Annual Occupational Radiation Exposure Data Reports - 2023 ML24120A0402024-04-29029 April 2024 Annual Radioactive Effluent Release Report for 2023 ML24094A2142024-04-19019 April 2024 Preapplication Readiness Assessment of the Holtec Decommissioning International License Termination Plan ML24089A2492024-03-29029 March 2024 Reply to Notice of Violation EA-2024-024 L-24-007, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations – Holtec Decommissioning International, LLC (HDI)2024-03-29029 March 2024 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations – Holtec Decommissioning International, LLC (HDI) ML24085A7902024-03-28028 March 2024 – Preapplication Readiness Assessment of the License Termination Plan ML24081A2882024-03-21021 March 2024 Request Preliminary Review and Feedback on Chapter 6 of the Draft License Termination Plan ML24046A1242024-02-29029 February 2024 – NRC Inspection Report 05000219/2023003 ML24033A3272024-02-0202 February 2024 Request Preliminary Review and Feedback on Chapter 5 of the Draft License Termination Plan ML23342A1162024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 IR 05000219/20230022023-11-0909 November 2023 EA-23-076 Oyster Creek Nuclear Generating Station - Notice of Violation and Proposed Imposition of Civil Penalty - $43,750 - NRC Inspection Report No. 05000219/2023002 ML23286A1552023-10-13013 October 2023 Defueled Safety Analysis Report (DSAR) ML23249A1212023-09-0606 September 2023 NRC Inspection Report 05000219/2023002, Apparent Violation (EA-23-076) ML23242A1162023-08-30030 August 2023 Biennial 10 CFR 50.59 and 10 CFR 72.48 Change Summary Report January 1, 2021 Through December 31, 2022 ML23214A2472023-08-22022 August 2023 NRC Inspection Report 05000219/2023002 IR 05000219/20230012023-05-31031 May 2023 NRC Inspection Report No. 05000219/2023001 IR 07200015/20234012023-05-16016 May 2023 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2023401 L-23-004, HDI Annual Occupational Radiation Exposure Data Reports - 20222023-04-24024 April 2023 HDI Annual Occupational Radiation Exposure Data Reports - 2022 ML23114A0912023-04-24024 April 2023 Annual Radioactive Effluent Release Report for 2022 ML23114A0872023-04-24024 April 2023 Annual Radioactive Environmental Operating Report for 2022 L-23-003, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-31031 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations ML23088A0382023-03-29029 March 2023 Stations 1, 2, & 3, Palisades Nuclear Plant, and Big Rock Point - Nuclear Onsite Property Damage Insurance ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities IR 05000219/20220022023-02-0909 February 2023 NRC Inspection Report No. 05000219/2022002 ML23031A3012023-02-0808 February 2023 Discontinuation of Radiological Effluent Monitoring Location in the Sewerage System ML23033A5052023-02-0202 February 2023 First Use Notification of NRC Approved Cask RT-100 ML23025A0112023-01-24024 January 2023 LLRW Late Shipment Investigation Report Per 10 CFR 20, Appendix G ML22347A2732022-12-21021 December 2022 Independent Spent Fuel Storage Installation Security Inspection Plan Dated December 21, 2022 ML22297A1432022-12-15015 December 2022 Part 20 App G Exemption Letter L-22-042, Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.152022-12-14014 December 2022 Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.15 IR 07200015/20224012022-12-0606 December 2022 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2022401 (Letter & Enclosure 1) ML22280A0762022-11-0202 November 2022 Us NRC Analysis of Holtec Decommissioning Internationals Funding Status Report for Oyster Creek, Indian Point and Pilgrim Nuclear Power Station ML22276A1762022-10-24024 October 2022 Decommissioning International Proposed Revisions to the Quality Assurance Program Approval Forms for Radioactive Material Packages ML22286A1402022-10-13013 October 2022 NRC Confirmatory Order EA-21-041 IR 05000219/20220012022-08-11011 August 2022 NRC Inspection Report 05000219/2022001 ML22215A1772022-08-0303 August 2022 Decommissioning International (HDI) Proposed Revisions to the Quality Assurance Program Approval Forms for Radioactive Material Packages ML22214A1732022-08-0202 August 2022 Request for Exemption from 10 CFR 20, Appendix G, Section Iii.E ML22207B8382022-07-26026 July 2022 NRC Confirmatory Order EA-21-041 ML22130A6882022-05-10010 May 2022 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G L-22-026, Occupational Radiation Exposure Data Report - 20212022-04-29029 April 2022 Occupational Radiation Exposure Data Report - 2021 2024-09-05
[Table view] |
Text
SUBJECT:
OYSTER CREEK GENERATING STATION - NRC SUPPLEMENTAL INSPECTION REPORT NO. 50-219/02-04
Dear Mr. Skolds:
On March 29, 2002, the NRC completed a supplemental inspection at your Oyster Creek reactor facility. During this inspection, the NRC reviewed evaluations and corrective actions completed by your staff in response to a White finding (i.e. a matter having low to moderate safety significance) involving a response strategy weakness identified during an Operational Safeguards Response Evaluation (OSRE) conducted May 7 - 10, 2001. The enclosed report documents the inspection findings which were discussed on March 29, 2002, with Mr. Ron DeGregorio and other members of your staff.
Based on the inspection results, we concluded that your evaluations were of adequate detail and commensurate with the significance of this performance issue. The inspector confirmed that your staff effectively identified the underlying causes of this matter, and implemented appropriate corrective actions.
Due to your acceptable performance in addressing this performance issue, consistent with the guidance contained in NRC Inspection Manual Chapter (IMC) 0305, Operating Reactor Assessment Program, this issue will only be considered in assessing plant performance for a total of four quarters from the date when the issue was identified on May 30, 2001. As specified in IMC 0305, a Regulatory Performance Meeting was conducted in a conference call on May 2, 2002, between your Security Manager, Mr. Rick Ewart, and Mr. John White of our staff. Previously, this matter was discussed in the Annual Public Meeting at Oyster Creek on April 11, 2002.
Mr. Jack Skolds -2-This report contains Safeguards Information (SGI) that must be protected against unauthorized disclosure in accordance with 10 CFR 73.21. In accordance with 10 CFR 2.790 of the NRCs Rules of Practice, a copy of this letter and the enclosed inspection report without the SGI enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Wayne D. Lanning, Director Division of Reactor Safety Docket No: 50-219 License No: DPR-16
Enclosure:
Inspection Report No. 50-219/02-04 (Contains Safeguards Information)
REGION I==
Docket No. 50-219 License No. DPR-16 Report No. 50-219/02-04 Licensee: AmerGen Energy Company, LLC Facility: Oyster Creek Generating Station Location: Forked River, New Jersey Dates: March 26-29, 2002 Inspector: Gregory C. Smith, Senior Physical Security Inspector Approved by: John R. White, Chief Radiation Safety and Safeguards Branch Division of Reactor Safety
SUMMARY OF FINDINGS
IR 05000219-02-04; on March 26-29, 2002; AmerGen Energy Company, LLC; Oyster Creek;
Action on White finding in the area of Physical Protection; Safeguards.
Cornerstone: Physical Protection
This supplemental inspection was performed by the NRC to assess AmerGens evaluations and corrective actions associated with a White finding involving a vulnerable protected strategy that resulted in the loss of a target set. This finding was identified during an Operational Safeguards Response Evaluation (OSRE) conducted May 7-10, 2001 and documented in inspection report 50-219/01-11 dated June 22, 2001. This current inspection was conducted in accordance with NRC Inspection Procedure 95001, Inspection for One or Two White Inputs in a Strategic Performance Area. The inspector determined that AmerGen effectively evaluated the finding, identified root and contributing causes, and established and implemented appropriate corrective actions. Consistent with the guidance contained in NRC Inspection Manual Chapter (IMC) 0305, Operating Reactor Assessment Program, this issue will only be considered in assessing plant performance for a total of four quarters from the date when the issue was identified on May 30, 2001.
ii 01
INSPECTION SCOPE
This supplemental inspection was performed to assess the licensees evaluations and corrective actions associated with a previously identified White finding involving the Physical Protection cornerstone of the Safeguards Strategic performance area.
Specifically, the White finding involved a vulnerability in the licensees protective strategy (i.e. the means and methods employed to protect against the design basis threat of radiological sabotage) that was identified as the result of an Operational Safeguard Response Evaluation (OSRE) conducted by the NRC on May 7-10, 2001.
Background The finding was preliminarily characterized as White (low to moderate risk significance)in NRC Inspection Report 50-219/01-11 dated June 22, 2001. Subsequently, this matter was discussed in a Regulatory Conference on August 3, 2001. Following the Regulatory Conference, the NRC considered the information provided by the licensee, made a final determination that issue constituted a White finding, and so informed the licensee in a letter dated August 28, 2001.
On September 12, 2001, the licensee appealed the NRCs final significance determination. On April 15, 2002, the NRC provided the results of the appeal and notified the licensee that the appeal panel concluded that the finding had been appropriately characterized as White, in accordance with NRC Manual Chapter 0609, Significance Determination Process.
EVALUATION OF INSPECTION REQUIREMENTS 02.01 THESE PARAGRAPHS CONTAIN AND IS NOT FOR PUBLIC DISCLOSURE - IT IS INTENTIONALLY LEFT BLANK.
THIS PAGE CONTAINS AND IS NOT FOR PUBLIC DISCLOSURE - IT IS INTENTIONALLY LEFT BLANK.
THIS PAGE CONTAINS AND IS NOT FOR PUBLIC DISCLOSURE - IT IS INTENTIONALLY LEFT BLANK.
THIS PAGE CONTAINS AND IS NOT FOR PUBLIC DISCLOSURE - IT IS INTENTIONALLY LEFT BLANK.
THIS PAGE CONTAINS AND IS NOT FOR PUBLIC DISCLOSURE - IT IS INTENTIONALLY LEFT BLANK.
THIS PARAGRAPH CONTAINS AND IS NOT FOR PUBLIC DISCLOSURE - IT IS INTENTIONALLY LEFT BLANK.
03 MANAGEMENT MEETINGS The inspector and the Radiation Safety and Safeguards Branch Chief met with licensee representatives on March 29, 2002. At that time, the purpose, scope, and findings were summarized.
KEY POINTS OF CONTACT Licensee E. Harkness Plant Manager J. Rogers Sr. Licensing Engineer R. Ewert Security Manager R. Pezzella Security Analyst M. Basti Security Analyst State of New Jersey D. Zannoni Dept. of Environmental Resources NRC L. Dudes Senior Resident Inspector, Oyster Creek J. White Chief, Radiation Safety and Safeguards Branch, DRS LIST OF ITEMS CLOSED Closed 50-219/01-11-01 FIN In an evaluated exercise (OSRE), the response strategy was insufficient to successfully interdict an adversary force. Based on this performance problem, the NRC OSRE team was unable to confirm that the design of the physical protection system was sufficient to protect against a design basis threat of radiological sabotage.
DOCUMENTS REVIEWED
Root Cause Report, CAP 02001-0796
Memo on OSRE, Lessons Learned, dated May 30, 2001
Oyster Creek Generating Station Procedure 307, Isolation Condenser System, Rev. 79, dated
January 18, 2002
Force-on-Force drill critiques for selected Force-on-Force drills conducted since May 2001
Oyster Creek Nuclear Generating Station NRC-Approved Physical Security Plan