ML19257A282

From kanterella
Revision as of 09:45, 18 October 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Final Deficiency Re Use of Incorrect Weld Acceptance Criteria on Reactor Pressure Vessel Pedestal Welds
ML19257A282
Person / Time
Site: Hartsville Tennessee Valley Authority icon.png
Issue date: 12/06/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19257A283 List:
References
NCR-HNP-A-073, NCR-HNP-A-73, NUDOCS 8001030550
Download: ML19257A282 (1)


Text

.

- 9 '

.

TEN"IESSEE VALLEY AUTHORITY CH ATTANOOG A. TENNESSEE 37401

^

400 Chestnut Street Tower II DecemberI 6, 1979 0N Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

HARTSVILLE NUCLEAR PLANT UNIT A1 REPORTABLE DEFICIENCY - USE OF INCORRECT WELD ACCEPTANCE CRI'ERIA ON REACTOR PRESSuca VESSEL PEDESTAL WELDS - NCR hTP-A-073 Initial report of the subject deficiency was made to R. W. Wright, NRC-0IE, Region II on November 11, 1979. In compliance with paragraph 50.55(e) of 10 CFR Part 50, we are enclosing the final report of the subject deficiency. If you have any questions concerning this subject, please call Jim Domer at FTS 854-2014.

Very truly yours, TENNESSEE VALLEY AUTHORITY h h?, / k L. M. Mills, Manager Nuclear Regulation and Safety Enclosure 1667 30b

-

I 550 An Equal Opportunity Employer 2001038 Teod