LER 80-055/03L-0:on 800816,during Performance of PT 15.2, MOV-FW-151A Failed to Indicate in Closed Position. Investigation Showed Valve in Open Position.Probably Caused by Mechanical Failure of Valve Operator
ML18139A501
Person / Time
Site: Surry Dominion icon.png
Issue date: 09/15/1980
From: WILSON J L
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139A500 List:
References
LER-80-055-03L, LER-80-55-3L, NUDOCS 8009190559
Download: ML18139A501 (2)


Text


*----

' ., ' NRC FORM 366 (7'77) e e S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT CONTROLBLOCK:J --'----'---'--'--....__,!(2) 1 6 (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

C§::E] I VI A I s I p I s I 11010 7 8 9 LICENSEE CODE 14 15 I O I -I O I O I O I O I O I -I O I O 101 4 I 1 I 1 I 1 I 1 101 I I 0 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T ITITI 7 8 l:'..J© I O I 5 I O I O I O I 2 I 8 I O 101 ° I 8 I 1 I 6 I 8 I O I© I o I 9 I 1 I s I s I o I@ 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES

<,o) l During performance of PT-15.2, MOv-Ft,Y-.1s1A failed to indicate in the closed position.

Investigation showed valve 1rema:ined in the open position.

Normal and. primary emergency considerations require valve to be open (in position to feed steam generator).

Steam ~enerator can be isolated by use of valves outside containment.

This condition is reportable in accordance with T.S. 6.6.2.b.(2).

The health and safety of the public were not affected.

[I]]] 7 8 9 80 [ill] 7 8 SYSTEM CODE I c1 RI@ 9 10 r;:;,, LER/RO LVENT YEAR REPORT 1 8 1 0 1 NUMBER 21 22 ACTION FUTURE TAKEN ACTION EFFECT ON PLANT CAUSE CAUSE CODE SUB CODE COMPONENT CODE L:J@ ~@ 1v IA IL 1v jE 1x I@ 11 12 13 SEQUENTIAL REPORT NO. l=.I Io Is Is I 23 24 26 lB OCCURRENCE CODE 1/I I 0 1 3 1 27 28 29 COMP. SUBCODE ~ 19 REPORT TYPE L::J 30 VALVE SUBCODE e.J@ 20 L=.J 31 SHUTDOWN METHOD HOURS {22) ATTACHMENT NPRD-4 PRIME COMP. SUPPLIER REVISION NO. 32 COMPONENT MANUFACTURER llJ SUBMITTED FORM SUB. I I ~@ ~@) 40 41 42 ~@ ~@~@ Li@ ~ 1° 1° 1° 33 34 35 36 37 jw Jo I 31 oj@ CAUSE DESCRIPTION Ar'j.D CORRECTIVE ACTIONS @ 43 44 47 J Mechanical failure of valve MOV-FW-151A prevented both remote and local operation.

MOV-FW-151A will be repaired during the next scheduled outage. ITEl 7 8 9 FACILITY '3a' STATUS % POWER OTHER STATUS Ci:TIJ L:J@ IO l 8 I 8 l@) ...... I ______ NA __ _. 80 METHOD OF @ DISCOVERY DISCOVERY DESCRIPTION

~I PT 15.2 8 9 10 12 13 ACTIVITY CONTENT (.;';;\ RELEASED OF RELEASE AMOUNT OF ACTIVITY e l.Ll@ W@I NA 7 8 9 10 11 44 45 46 80 _LOCATION OF RELEASE @) NA 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION

[ilD I o I o I ~6t2.J@ ____ , _N_A ____________________

_ 7 8 9 11 12 13 80 PERSONNEL INJURIES NUMBER DESCRIPTION6 I 01 0 I Ol@ ______ N_A ___________________

_ 7 8 9 11 12 LOSS OF OR DAMAGE TO FACILITY 0 TYPE DESCRIPTION 80 NA 7 8 91 I PUBLICITY

(";;;\ . ISSUEDQDESCRIPTION NRCUSEONLY

"' ITli] l.N.J6 ........ ________ N_A ____________

-..J I II I I II II I II I 7 8 9 10 -,::::q 68 69 80 0: 8 0 0 9 1 9* {iF PREPARER __ J_. _L_._w_i_l_so_n________

PHONE: __ (.;..8_0_4_)_35_7_-_3_1_8_4

___

",, . , -*-**----*

---*"---~--

  • ---*--------*--*-~-------**-*-

. ,**-**------*J:::.~-<~--------*---

,~~---~-~----J"~~-~--

e ATTACHMENT I (PAGE l OF 1) SURRY POWER STATION, UNIT l DOCKET NO: 50-280 REPORT NO: 80-055/03L-0 EVENT DATE: 08-16-80 TITLE OF EVENT: MOV-FW-151A FAILURE TO OPERATE 1. DESCRIPTION OF EVENT: e During performance of PT 15.2, MOV-FW-151A failed to indicate in the closed position.

Investigation showed valverr.emained in the open position .. Normal and primary emergency considerations require valve to be open (in position to feed steam generator).

This condition is reportable in accordance with T.S. 6.6.2. b. (2)

  • 2. PROBABLE CONSEQUENCES AND STATUS OF REDUNDANT SYSTEMS: MOV-FW-151A is in a position that will provide emergency feedwater to 'C' Steam Generator as required for a Loss of Normal Feedwater event. If auxiliary feedwater is required to be isolated from 'C' Steam Generator, sufficient time is available for manual isolation outside of the containment.

Therefore, the health and safety of the public has not been affected.

3. CAUSE OF THE EVENT: Mechanical failure of the valve operator is suspected at this time. 4. IMMEDIATE CORRECTIVE ACTION: Investigatedreason for valve failure. Verified valve in the required position, i.e. open. 5. SUBSEQUENT CORRECTIVE ACTION: Instructions provided to the operating staff for method of manual isolation, if required.
6. FUTURE CORRECTIVE ACTION: The valve will be repaired at the next scheduled outage.and failure mode firmed. 7. GENERIC IMPLICATIONS:

None